This document appears to be a technical drawing and specifications for a 36-inch HDPE precast modular sloped headwall, provided as an exhibit for a competitive bid opportunity (CRFQ DOT2500000019) with the West Virginia Department of Transportation, Division of Highways. The headwall is designed for use with a 36-inch I.D. profile wall HDPE pipe, with details on the dimensions, reinforcement, bolted connections, and square blockouts to connect adjacent headwalls. The drawings include notes on installation requirements, such as grouting the pipe into the receiving channel and chamfering edges. No additional details are provided regarding the overall contract scope, quantities, response dates, award information, or pricing terms.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

35°

4'-6"

6"

3'-6"6"

3'-0"

3'-6"

1'-0"

8"

6'-8"

8"

4'-11.5"

5'-11.5"

8"

MIDLINE OF PIPE BARREL. (2 EACH SIDE)

BOLTED CONNECTION. PLACED ALONG

WITH 1.5" DIAMETER HOLE FOR RECESSED

4"W X 4"H X 3"D SQUARE BLOCKOUT

CENTER OF MASS IN TOP FACE.

LIFTING LUGS PLACED NEAR

1'-8"

County Sheet Sheets Total

No.Year

Fiscal Project No.

Federal

No.

Project

State

No.

Dist.

State

Div.

Roads Public

3W.V.

THE WEST VIRGINIA DEPARTMENT OF TRANSPORTATION

DIVISION OF HIGHWAYS

DETAIL

-30/2- S337

0.01

2023 PLEASANTS

PRECAST MODULAR SLOPED HEADWALL - 36" HDPE

1'

4'-11.5"

BOLTED CONNECTIONS WILL BE GROUTED AFTER PLACEMENT TO PROVIDE A SMOOTH SURFACE.

4. SQUARE BLOCKOUTS TO BE PLACED ALONG MIDLINE OF PIPE BARREL TO CONNECT ADJACENT HEADWALLS.

3. TOP AND FRONT EDGES TO BE CHAMFERED 3/4". FOOTING AND SIDE EDGES ARE NOT TO BE CHAMFERED.

2. REINFORCEMENT IS TO BE PER HEADWALL MANUFACTURER.

36" HDPE PIPE WILL BE INSERTED INTO 8" DEEP RECEIVING CHANNEL AND GROUTED IN PLACE.

1. PRECAST SLOPED HEADWALL IS SIZED FOR A 36" I.D. PROFILE WALL HDPE PIPE WITH O.D. OF 41".