This solicitation seeks proposals for the renovation of a Squadron Operations Area at Eglin Air Force Base in Florida. The project includes selective demolition of existing interior construction and finishes, modifications to supply and tool rooms, modifying an existing SAPF to ICD 705 standards and converting a second SAPF into a SCIF. The performance period is anticipated to be 300 days after notice to proceed. The North American Industry Classification System code is 236220 and the size standard is $39.5 million. This is a 100% 8(a) small business set-aside utilizing best value source selection. The statement of magnitude is between $1,000,000 and $5,000,000. Proposals are due no later than June 4, 2021 at 1300 Central Time through the DoD SAFE system. Funds have not been obligated and the Government reserves the right to cancel before or after the closing date with no obligation to reimburse offerors.

View the file

Other files

Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 1 1

1 1

6 6 6 6

6 6 6

8 7 7 2 7

7 8

7 2 7 2

2 2 2 2 2 2 2 2

1 1 11

1 1 1

77777

ELECTRICAL

BOILER ROOM

MECH.

COMM.

MASS BRIEFING

ROOM

BRIEF RM 6

BRIEF RM 5

BRIEF RM 4

BRIEF RM 3

KITCHEN

SECURITY

SARM

SAFETY SUPV.

CONFERENCE

ROOM

CC

DO

SHIRT

SCHED

DOS

AT VAULT

AT SUPV. OFICE

ADAIR MX

HALL

AMW PMA

AE SUPV. OFFICE

ADAIR MX

KITCHEN

ADAIR MX

HALL

ADAIR MX

ADAIR OPS

ADAIR OPS

HALL

OPS DESK

AST OIC /

SEC MGR

PROD SUPERS

BREAK ROOM

SERVER ROOM

ALIS

MISSION

PLANNING

RESTROOM

BRIEF ROOM 2

BRIEF ROOM 1

WEAPONS / INTEL

STAN EVAL

TRAINING

ADAIR OPS

ADAIR OPS

ADAIR OPS

MENS LOCKER

VEST.

MENS

WOMENS

WOMENS LOCKER

1ST LT.

OFFICE

HALL

JAN

AFE

OFFICE

AFE WORK AREA

SO

FS

WOMENS

MENS

WASH/DRY

HELMET TESTING

FIT / CC

STUDENT ROOM

FIT / CC

CO SEC. WAITING

HERITAGE ROOM

HALL

QUARTER DECK

VEST.

HALL

HALL

142 HALL

KEY NOTES:

1 ALL EXISTING COMMUNICATION OUTLETS WITHIN THIS

AREA SHALL REMAIN FOR FUTURE USE. ANY OUTLETS

LOCATED ON WALLS THAT ARE TO BE REMOVED SHALL

HAVE OUTLET AND ASSOCIATED CABLING REMOVED

BACK TO SOURCE.

2 EXISTING CATV HEADEND LOCATION.

3 EXISTING CABLE TRAY TO REMAIN.

2 3 4 5 6 7 82.2 7.8 8.8

C

D

E

F

G

H

J

D.7

E.3

E.5

3.6 6.7 10.59 10 11

T-401A

REVISION DATE DESCRIPTION BY APPR'D

BASE CIVIL ENGINEER

EGLIN AIR FORCE BASE, FLORIDA

DATE

SIGNATURE

APPROVED

CENM

DRAWN BY

PROJ. ENGR.

CONTENTS

APPROVED

TITLE

DATE

SCALE

SHEET OF

SPEC. NO.

INDEX NO.

PROJ. NO. DRAWING NO. FILE NO.

96/CEG/CEN

APPROVED

DEPUTY BASE CIVIL ENGINEER

APPROVED

PROGRAM MANAGER

APPROVED

FIRE PREVENTION

APPROVED

SAFETY REPRESENTATIVE

APPROVED

DIR. BASE. MED. SERVICE

APPROVED

USING AGENCY

APPROVED

COMMUNICATIONS

APPROVED

OPERATIONS ENGINEERING

APPROVED

ENVIRONMENTAL

APPROVED

SECURITY FORCES

APPROVED

ASUS

APPROVED

CHELCO

20AH FTFA20CB73

RENOVATE SQUADRON

OPERATIONS AREA JSF

HANGAR B1412

1/26/2021

T-101

TELECOM EXISTING PARTIAL PLAN SW

TBG

DMB

1/8" = 1'-0"T-101

1 EXISTING TELECOM PLAN SW

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

KEY PLAN

1 4/1/2021 REVISION 1

L L

BAGW

E

M.

LIC N

AVID

No. 59251

SD E

AL EN

S IO

R O

F

ES

P

N

STATE OF

G

IN

E E

R

E

ADIL R

F O

1 1 1

1 1

6 6 6 6

6 6 6

8 7 7 2 7

7 8

7 2 7 2

2 2 2 2 2 2 2 2

1 1 11

1 1 1

1111111

1 1 1 1

1 2

F P

F P

F P

P R

P R

AV

AV

AV

AV

AV

77777

1 1 1

C R

1 1 1

4 4 4 4 4 4

8 9

ELECTRICAL

BOILER ROOM

MECH.

COMM.

MASS BRIEFING

ROOM

BRIEF RM 6

BRIEF RM 5

BRIEF RM 4

BRIEF RM 3

KITCHEN

SECURITY

SARM

SAFETY SUPV.

CONFERENCE

ROOM

CC

DO

SHIRT

SCHED

DOS

AT VAULT

AT SUPV. OFICE

ADAIR MX

HALL

AMW PMA

AE SUPV. OFFICE

ADAIR MX

KITCHEN

ADAIR MX

HALL

ADAIR MX

ADAIR OPS

ADAIR OPS

HALL

OPS DESK

AST OIC /

SEC MGR

PROD SUPERS

BREAK ROOM

SERVER ROOM

ALIS

MISSION

PLANNING

RESTROOM

BRIEF ROOM 2

BRIEF ROOM 1

STAN EVAL

TRAINING

ADAIR OPS

ADAIR OPS

ADAIR OPS

MENS LOCKER

VEST.

MENS

WOMENS

WOMENS LOCKER

1ST LT.

OFFICE

HALL

JAN

AFE

OFFICE

AFE WORK AREA

SO

188 FS

WOMENS

MENS

WASH/DRY

HELMET TESTING

FIT / CC

STUDENT ROOM

FIT / CC

CO SEC. WAITING

HERITAGE ROOM

HALL

QUARTER DECK

T-401A

T-401

KEY NOTES:

1 ALL NEW COMMUNICATION OUTLETS WITHIN

THIS AREA SHALL BE SERVED BY EXISTING COMM.

ROOM 121 UNLESS NOTED OTHERWISE.

2 EXISTING WEST SECURE AREA BOUNDARY. ALL NEW

COMMUNICATION OUTLETS WITHIN THIS AREA

(EXCEPT YELLOW AND LIGHT BLUE TYPE) SHALL BE

SERVED FROM SERVER ROOM 134 (UNO).

3 WALL MOUNT CABINET FOR YELLOW NETWORK

EQUIPMENT.

4 INSTALL COPPER PAIR BELOW DROP CEILING IN 1"

CONDUIT AND LEAVE 6'-8" SLACK. INSTALL COPPER

CABLING WILL COME FROM COMM ROOM 121.

TERMINATE TO TELEPHONE 66 BLOCK.

5 INSTALL 1" CONDUIT WITH PULL STRING FROM

EXISTING CARD READER LOCATION TO SSO/ISSO

ROOM 418. CONTRACTOR TO HIRE ALLIED

UNIVERSAL TO INSTALL WIRING FROM THE DEVICE

TO THE ACS PANEL IN ROOM 418. ALLIED TO

PROGRAM THE PANEL AS REQUIRED PER THE

DIRECTION OF THE GOVERMENT.

6 INSTALL NEW CABINET FOR EXISTING RED

NETWORK EQUIPMENT. RELOCATE EXISTING RED

NETWORK EQUIPMENT TO WALL MOUNT CABLINET.

PROVIDE 24 STRAND FIBER FROM THE EXISTING

RACK TO THE NEW WALL MOUNT CABINET.

7 INSTALL 24" x 24" x 12" JUNCTION BOX LOCATED

ABOVE CEILING IN INTEL ROOM 141 TO SUPPORT

CATV DEVICES LOCATED WITHIN THE SAPF AREA.

INSTALL A 1" CONDUIT WITH PULLSTRING FROM

JUNCTION BOX TO EXISTING CATV HEADEND IN

ROOM 121. REFER TO CATV RISER FOR ADDITIONAL

INFORMATION.

8 INSTALL A FOUR STRAND FIBER OPTIC CABLE IN 1"

CONDUIT TO SERVER ROOM 134. CONNECT THE

FIBER TO AN OUTLET WITH TWO LC CONNECTORS.

CONNECTOR COLOR TO BE DETERMINED BY GOV'T.

TERMINATE FIBER TO EXISTING UNCLASS RACK IN

SERVER ROOM PER GOV'T DIRECTION.

2 3 4 5 6 7 82.2 7.8 8.8

C

D

E

F

G

H

J

D.7

E.3

E.5

3.6 6.7 10.59 10 11

GENERAL NOTES:

1. ALL CABLE TRAYS SHOWN ARE EXISTING UNLESS

NOTED OTHERWISE.

2. NEW OUTLETS INSTALLED IN ROOMS 129, 136, AND

141 (EXCEPT YELLOW AND LIGHT BLUE TYPE) SHALL

BE SERVED FROM EXISTING RACKS IN SERVER

ROOM 134 (UNO).

INSTALLATION NOTE: WHEN INSTALLING A NIPR OUTLET IN AN

UNSECURE LOCATION, DO NOT STALL NIPR CABLING THROUGH

A SECURE SPACE. ROUTE CABLING AROUND SECURE SPACES.

WEAPONS / INTEL

LIGHT BLUE NETWORK OUTLET IN MASS BRIEFING

ROOM 129 SHALL BE SERVED FROM NETWORK

EQUIPMENT IN SECURITY OFFICE ROOM 118.

SECURE AREA BOUNDARY FOR WEAPONS / INTEL

ROOM 141. CONTRACTOR TO PROVIDE DIELECTRIC

BREAKS AS REQUIRED WHEN PENETRATING THE

SECURE AREA BOUNDARY.

9 GOVERNMENT TO RE-LABEL THE COMMUNICATIONS

OUTLETS IN ROOM 135 ONCE PATCHED TO

SUPPORT ALIS ADMINS.

10 GOVERNMENT SHALL PROVIDE REQUIRED

TELEPHONE.

REVISION DATE DESCRIPTION BY APPR'D

BASE CIVIL ENGINEER

EGLIN AIR FORCE BASE, FLORIDA

DATE

SIGNATURE

APPROVED

CENM

DRAWN BY

PROJ. ENGR.

CONTENTS

APPROVED

TITLE

DATE

SCALE

SHEET OF

SPEC. NO.

INDEX NO.

PROJ. NO. DRAWING NO. FILE NO.

96/CEG/CEN

APPROVED

DEPUTY BASE CIVIL ENGINEER

APPROVED

PROGRAM MANAGER

APPROVED

FIRE PREVENTION

APPROVED

SAFETY REPRESENTATIVE

APPROVED

DIR. BASE. MED. SERVICE

APPROVED

USING AGENCY

APPROVED

COMMUNICATIONS

APPROVED

OPERATIONS ENGINEERING

APPROVED

ENVIRONMENTAL

APPROVED

SECURITY FORCES

APPROVED

ASUS

APPROVED

CHELCO

20AH FTFA20CB73

RENOVATE SQUADRON

OPERATIONS AREA JSF

HANGAR B1412

1/26/2021

T-111

TELECOM PARTIAL FLOOR PLAN SW

TBG

DMB

N

1/8" = 1'-0"T-111

1 NEW TELECOM PLAN SW

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

KEY PLAN

1 4/1/2021 REVISION 1

L L

BAGW

E

M.

LIC N

AVID

No. 59251

SD E

AL EN

S IO

R O

F

ES

P

N

STATE OF

G

IN

E E

R

E

SERVER ROOM

2019.8

F

T-501

T-501

T-501

434-A

UNCLASS

BLUE

434-B

434-G

BROWN

434-F

BLUE

434-E

LIGHT

BLUE

434-D

RED

434-C

YELLOW

11111

SERVER ROOM

2019.8

F

SERVER ROOM

2 2.2

F

T-502

REVISION DATE DESCRIPTION BY APPR'D

BASE CIVIL ENGINEER

EGLIN AIR FORCE BASE, FLORIDA

DATE

SIGNATURE

APPROVED

CENM

DRAWN BY

PROJ. ENGR.

CONTENTS

APPROVED

TITLE

DATE

SCALE

SHEET OF

SPEC. NO.

INDEX NO.

PROJ. NO. DRAWING NO. FILE NO.

96/CEG/CEN

APPROVED

DEPUTY BASE CIVIL ENGINEER

APPROVED

PROGRAM MANAGER

APPROVED

FIRE PREVENTION

APPROVED

SAFETY REPRESENTATIVE

APPROVED

DIR. BASE. MED. SERVICE

APPROVED

USING AGENCY

APPROVED

COMMUNICATIONS

APPROVED

OPERATIONS ENGINEERING

APPROVED

ENVIRONMENTAL

APPROVED

SECURITY FORCES

APPROVED

ASUS

APPROVED

CHELCO

20AH FTFA20CB73

RENOVATE SQUADRON

OPERATIONS AREA JSF

HANGAR B1412

1/26/2021

T-401

TELECOM ENLARGED PLANS

TBG

DMB

TELECOM ENLARGED PLAN KEY NOTES:

1 FLOOR MOUNT LOCKABLE 4-POST COMMUNICATIONS RACK. GREAT

LAKES GL790ES-2442MS OR EQUAL. PROVIDE VERTICAL CABLE

MANAGEMENT, VCT-79 OR EQUAL. PROVIDE CABLE MANAGEMENT

COVER, VCT-79C OR EQUAL.

2 EXISTING LADDER TRAY.

1/2" = 1'-0"T-401

1 ENLARGED SERVER ROOM 434 EQUIPMENT PLAN

1/2" = 1'-0"T-401

2 ENLARGED SERVER ROOM 434 OVERHEAD TRAY PLAN

1/2" = 1'-0"T-401

ENLARGED SERVER ROOM 134 OVERHEAD

TRAY PLAN

1 4/1/2021 REVISION 1

L L

BAGW

E

M.

LIC N

AVID

No. 59251

SD E

AL EN

S IO

R O

F

ES

P

N

STATE OF

G

IN

E E

R

E

SERVER ROOM

2 2.2

F

T-502

T-502

134-A

UNCLASS

NIPR BLUE

134-B

UNCLASS

LM GREEN

134-C

SECURE LM

BLUE AND

LM RED

134-D SIPR

RED

1 3

EXISTING

RACK 3

EXISTING

RACK 2

2 2.2

F

SERVER ROOM

EXISTING

RACK 1

1 2

EXISTING

RACK 2

EXISTING

RACK 3

REVISION DATE DESCRIPTION BY APPR'D

BASE CIVIL ENGINEER

EGLIN AIR FORCE BASE, FLORIDA

DATE

SIGNATURE

APPROVED

CENM

DRAWN BY

PROJ. ENGR.

CONTENTS

APPROVED

TITLE

DATE

SCALE

SHEET OF

SPEC. NO.

INDEX NO.

PROJ. NO. DRAWING NO. FILE NO.

96/CEG/CEN

APPROVED

DEPUTY BASE CIVIL ENGINEER

APPROVED

PROGRAM MANAGER

APPROVED

FIRE PREVENTION

APPROVED

SAFETY REPRESENTATIVE

APPROVED

DIR. BASE. MED. SERVICE

APPROVED

USING AGENCY

APPROVED

COMMUNICATIONS

APPROVED

OPERATIONS ENGINEERING

APPROVED

ENVIRONMENTAL

APPROVED

SECURITY FORCES

APPROVED

ASUS

APPROVED

CHELCO

20AH FTFA20CB73

RENOVATE SQUADRON

OPERATIONS AREA JSF

HANGAR B1412

1/26/2021

T-401A

TELECOM ENLARGED PLANS

Author

Approver

1/2" = 1'-0"T-401A

ENLARGED SERVER ROOM 134 EQUIPMENT

PLAN - NEW

1/2" = 1'-0"T-401A

ENLARGED SERVER ROOM 134 EQUIPMENT

PLAN - EXISTING

EXISTING ENLARGED PLAN KEY NOTES:

1 EMPTY LOCKABLE COMMUNICATION CABINET TO

BE MOVED AND UTILIZED FOR EXISTING NIPR. SEE

NEW WORK PLAN FOR NEW LOCATION.

2 EXISTING 4-POST RACK CONTAINING SIPR DROPS.

3 EXISTING 4-POST RACK WITH NIPR DROPS.

NEW ENLARGED PLAN KEY NOTES:

1 USE EXISTING LOCKABLE COMM CABINET TO HOUSE EXISTING 96 CS NIPR

ASSOCIATED EQUIPMENT (NIPR PATCH PANELS, TOP FIBER OPTIC

DISTRIBUTION PANEL, AND 2 EACH RECEPTACLE CIRCUITS) MOVED FROM RACK 3.

2 MOVE SIPR CABLES FROM THIS RACK AND INSTALL IN NEW PATCH PANEL IN WALL

MOUNTED RACK 4. LEAVE ALL OTHER CABLES/EQUIPMENT.

3 LEAVE REMAINING EQUIPMENT ITEMS IN THIS RACK AFTER RELOCATING THOSE

REQUIRED TO 96 COMM UNCLASS RACK. (REFER TO NOTE 1)

4 NEW WALL MOUNTED LOCKABLE CABINET FOR 96 COMM SIPR MODEL NUMBER

EWMWG362425 36" X 24" X 25" CABINET WITH WINDOW DOOR AND GLAND PLATE 19

RACK UNITS.

R A

C K

1 4/1/2021 REVISION 1

L L

BAGW

E

M.

LIC N

AVID

No. 59251

SD E

AL EN

S IO

R O

F

ES

P

N

STATE OF

G

IN

E E

R

E

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

1 2 3 4 5 6 7 8 9 10 11 12

34 35 36 37 38 39 40 41 42 43

13 14 15 16 17 18 19 20 21 22 23

44 45 46 47 48

25 26 27 28 29 30 31 32 33

134-A

BLUE

4RED NEW FIBER L.I.U.

134-D

REVISION DATE DESCRIPTION BY APPR'D

BASE CIVIL ENGINEER

EGLIN AIR FORCE BASE, FLORIDA

DATE

SIGNATURE

APPROVED

CENM

DRAWN BY

PROJ. ENGR.

CONTENTS

APPROVED

TITLE

DATE

SCALE

SHEET OF

SPEC. NO.

INDEX NO.

PROJ. NO. DRAWING NO. FILE NO.

96/CEG/CEN

APPROVED

DEPUTY BASE CIVIL ENGINEER

APPROVED

PROGRAM MANAGER

APPROVED

FIRE PREVENTION

APPROVED

SAFETY REPRESENTATIVE

APPROVED

DIR. BASE. MED. SERVICE

APPROVED

USING AGENCY

APPROVED

COMMUNICATIONS

APPROVED

OPERATIONS ENGINEERING

APPROVED

ENVIRONMENTAL

APPROVED

SECURITY FORCES

APPROVED

ASUS

APPROVED

CHELCO

20AH FTFA20CB73

RENOVATE SQUADRON

OPERATIONS AREA JSF

HANGAR B1412

1/26/2021

T-502

RACK ELEVATIONS

TBG

DMB

1 1/2" = 1'-0"T-502

UNCLASS NETWORK RACK ELEVATION - COMM

ROOM 134

1 1/2" = 1'-0"T-502

CLASSIFIED NETWORK RACK ELEVATION -

COMM ROOM 134

RACK ELEVATION KEY NOTES:

1 EXISTING COMMUNICATIONS RACK.

2 EXISTING COPPER PATCH PANEL.

3 NEW WALL MOUNTED LOCKABLE CABINET FOR 96 COMM

SIPR MODEL NUMBER EWMWG362425 36" X 24" X 25"

CABINET WITH WINDOW DOOR AND GLAND PLATE 19 RACK

UNITS.

4 24 PORT SCREENED TWISTED PAIR (ScTP) CATEGORY 6

HORIZONTAL PATCH PANEL.

5 EXISTING FIBER L.I.U.

6 NEW FIBER L.I.U.

NOTE: ALL SIPR CABLES SHALL BE DISCONNECTED FROM

EXISTING UNCLASS CABINET PULLED BACK, REROUTED, AND

TERMINATED TO NEW PATCH PANEL IN CLASSIFIED WALL MOUNT

CABINET. NO CLASSIFIED CABLING SHALL REMAIN IN THE

EXISTING UNCLASS RACK (134-A)

1 4/1/2021 REVISION 1

L L

BAGW

E

M.

LIC N

AVID

No. 59251

SD E

AL EN

S IO

R O

F

ES

P

N

STATE OF

G

IN

E E

R

E

Sheets
T-101 - TELECOM EXISTING PARTIAL PLAN SW
T-111 - TELECOM PARTIAL FLOOR PLAN SW
T-401 - TELECOM ENLARGED PLANS
T-401A - TELECOM ENLARGED PLANS
T-502 - RACK ELEVATIONS

File details come from the government source that posted it. Updated .