This solicitation seeks proposals for the renovation of a Squadron Operations Area at Eglin Air Force Base in Florida. The project includes selective demolition of existing interior construction and finishes, modifications to supply and tool rooms, modifying an existing SAPF to ICD 705 standards and converting a second SAPF into a SCIF. The performance period is anticipated to be 300 days after notice to proceed. The North American Industry Classification System code is 236220 and the size standard is $39.5 million. This is a 100% 8(a) small business set-aside utilizing best value source selection. The statement of magnitude is between $1,000,000 and $5,000,000. Proposals are due no later than June 4, 2021 at 1300 Central Time through the DoD SAFE system. Funds have not been obligated and the Government reserves the right to cancel before or after the closing date with no obligation to reimburse offerors.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1 1
1 1
6 6 6 6
6 6 6
8 7 7 2 7
7 8
7 2 7 2
2 2 2 2 2 2 2 2
1 1 11
1 1 1
77777
ELECTRICAL
BOILER ROOM
MECH.
COMM.
MASS BRIEFING
ROOM
BRIEF RM 6
BRIEF RM 5
BRIEF RM 4
BRIEF RM 3
KITCHEN
SECURITY
SARM
SAFETY SUPV.
CONFERENCE
ROOM
CC
DO
SHIRT
SCHED
DOS
AT VAULT
AT SUPV. OFICE
ADAIR MX
HALL
AMW PMA
AE SUPV. OFFICE
ADAIR MX
KITCHEN
ADAIR MX
HALL
ADAIR MX
ADAIR OPS
ADAIR OPS
HALL
OPS DESK
AST OIC /
SEC MGR
PROD SUPERS
BREAK ROOM
SERVER ROOM
ALIS
MISSION
PLANNING
RESTROOM
BRIEF ROOM 2
BRIEF ROOM 1
WEAPONS / INTEL
STAN EVAL
TRAINING
ADAIR OPS
ADAIR OPS
ADAIR OPS
MENS LOCKER
VEST.
MENS
WOMENS
WOMENS LOCKER
1ST LT.
OFFICE
HALL
JAN
AFE
OFFICE
AFE WORK AREA
SO
FS
WOMENS
MENS
WASH/DRY
HELMET TESTING
FIT / CC
STUDENT ROOM
FIT / CC
CO SEC. WAITING
HERITAGE ROOM
HALL
QUARTER DECK
VEST.
HALL
HALL
142 HALL
KEY NOTES:
1 ALL EXISTING COMMUNICATION OUTLETS WITHIN THIS
AREA SHALL REMAIN FOR FUTURE USE. ANY OUTLETS
LOCATED ON WALLS THAT ARE TO BE REMOVED SHALL
HAVE OUTLET AND ASSOCIATED CABLING REMOVED
BACK TO SOURCE.
2 EXISTING CATV HEADEND LOCATION.
3 EXISTING CABLE TRAY TO REMAIN.
2 3 4 5 6 7 82.2 7.8 8.8
C
D
E
F
G
H
J
D.7
E.3
E.5
3.6 6.7 10.59 10 11
T-401A
REVISION DATE DESCRIPTION BY APPR'D
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
DATE
SIGNATURE
APPROVED
CENM
DRAWN BY
PROJ. ENGR.
CONTENTS
APPROVED
TITLE
DATE
SCALE
SHEET OF
SPEC. NO.
INDEX NO.
PROJ. NO. DRAWING NO. FILE NO.
96/CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
APPROVED
PROGRAM MANAGER
APPROVED
FIRE PREVENTION
APPROVED
SAFETY REPRESENTATIVE
APPROVED
DIR. BASE. MED. SERVICE
APPROVED
USING AGENCY
APPROVED
COMMUNICATIONS
APPROVED
OPERATIONS ENGINEERING
APPROVED
ENVIRONMENTAL
APPROVED
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
20AH FTFA20CB73
RENOVATE SQUADRON
OPERATIONS AREA JSF
HANGAR B1412
1/26/2021
T-101
TELECOM EXISTING PARTIAL PLAN SW
TBG
DMB
1/8" = 1'-0"T-101
1 EXISTING TELECOM PLAN SW
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
KEY PLAN
1 4/1/2021 REVISION 1
L L
BAGW
E
M.
LIC N
AVID
No. 59251
SD E
AL EN
S IO
R O
F
ES
P
N
STATE OF
G
IN
E E
R
E
ADIL R
F O
1 1 1
1 1
6 6 6 6
6 6 6
8 7 7 2 7
7 8
7 2 7 2
2 2 2 2 2 2 2 2
1 1 11
1 1 1
1111111
1 1 1 1
1 2
F P
F P
F P
P R
P R
AV
AV
AV
AV
AV
77777
1 1 1
C R
1 1 1
4 4 4 4 4 4
8 9
ELECTRICAL
BOILER ROOM
MECH.
COMM.
MASS BRIEFING
ROOM
BRIEF RM 6
BRIEF RM 5
BRIEF RM 4
BRIEF RM 3
KITCHEN
SECURITY
SARM
SAFETY SUPV.
CONFERENCE
ROOM
CC
DO
SHIRT
SCHED
DOS
AT VAULT
AT SUPV. OFICE
ADAIR MX
HALL
AMW PMA
AE SUPV. OFFICE
ADAIR MX
KITCHEN
ADAIR MX
HALL
ADAIR MX
ADAIR OPS
ADAIR OPS
HALL
OPS DESK
AST OIC /
SEC MGR
PROD SUPERS
BREAK ROOM
SERVER ROOM
ALIS
MISSION
PLANNING
RESTROOM
BRIEF ROOM 2
BRIEF ROOM 1
STAN EVAL
TRAINING
ADAIR OPS
ADAIR OPS
ADAIR OPS
MENS LOCKER
VEST.
MENS
WOMENS
WOMENS LOCKER
1ST LT.
OFFICE
HALL
JAN
AFE
OFFICE
AFE WORK AREA
SO
188 FS
WOMENS
MENS
WASH/DRY
HELMET TESTING
FIT / CC
STUDENT ROOM
FIT / CC
CO SEC. WAITING
HERITAGE ROOM
HALL
QUARTER DECK
T-401A
T-401
KEY NOTES:
1 ALL NEW COMMUNICATION OUTLETS WITHIN
THIS AREA SHALL BE SERVED BY EXISTING COMM.
ROOM 121 UNLESS NOTED OTHERWISE.
2 EXISTING WEST SECURE AREA BOUNDARY. ALL NEW
COMMUNICATION OUTLETS WITHIN THIS AREA
(EXCEPT YELLOW AND LIGHT BLUE TYPE) SHALL BE
SERVED FROM SERVER ROOM 134 (UNO).
3 WALL MOUNT CABINET FOR YELLOW NETWORK
EQUIPMENT.
4 INSTALL COPPER PAIR BELOW DROP CEILING IN 1"
CONDUIT AND LEAVE 6'-8" SLACK. INSTALL COPPER
CABLING WILL COME FROM COMM ROOM 121.
TERMINATE TO TELEPHONE 66 BLOCK.
5 INSTALL 1" CONDUIT WITH PULL STRING FROM
EXISTING CARD READER LOCATION TO SSO/ISSO
ROOM 418. CONTRACTOR TO HIRE ALLIED
UNIVERSAL TO INSTALL WIRING FROM THE DEVICE
TO THE ACS PANEL IN ROOM 418. ALLIED TO
PROGRAM THE PANEL AS REQUIRED PER THE
DIRECTION OF THE GOVERMENT.
6 INSTALL NEW CABINET FOR EXISTING RED
NETWORK EQUIPMENT. RELOCATE EXISTING RED
NETWORK EQUIPMENT TO WALL MOUNT CABLINET.
PROVIDE 24 STRAND FIBER FROM THE EXISTING
RACK TO THE NEW WALL MOUNT CABINET.
7 INSTALL 24" x 24" x 12" JUNCTION BOX LOCATED
ABOVE CEILING IN INTEL ROOM 141 TO SUPPORT
CATV DEVICES LOCATED WITHIN THE SAPF AREA.
INSTALL A 1" CONDUIT WITH PULLSTRING FROM
JUNCTION BOX TO EXISTING CATV HEADEND IN
ROOM 121. REFER TO CATV RISER FOR ADDITIONAL
INFORMATION.
8 INSTALL A FOUR STRAND FIBER OPTIC CABLE IN 1"
CONDUIT TO SERVER ROOM 134. CONNECT THE
FIBER TO AN OUTLET WITH TWO LC CONNECTORS.
CONNECTOR COLOR TO BE DETERMINED BY GOV'T.
TERMINATE FIBER TO EXISTING UNCLASS RACK IN
SERVER ROOM PER GOV'T DIRECTION.
2 3 4 5 6 7 82.2 7.8 8.8
C
D
E
F
G
H
J
D.7
E.3
E.5
3.6 6.7 10.59 10 11
GENERAL NOTES:
1. ALL CABLE TRAYS SHOWN ARE EXISTING UNLESS
NOTED OTHERWISE.
2. NEW OUTLETS INSTALLED IN ROOMS 129, 136, AND
141 (EXCEPT YELLOW AND LIGHT BLUE TYPE) SHALL
BE SERVED FROM EXISTING RACKS IN SERVER
ROOM 134 (UNO).
INSTALLATION NOTE: WHEN INSTALLING A NIPR OUTLET IN AN
UNSECURE LOCATION, DO NOT STALL NIPR CABLING THROUGH
A SECURE SPACE. ROUTE CABLING AROUND SECURE SPACES.
WEAPONS / INTEL
LIGHT BLUE NETWORK OUTLET IN MASS BRIEFING
ROOM 129 SHALL BE SERVED FROM NETWORK
EQUIPMENT IN SECURITY OFFICE ROOM 118.
SECURE AREA BOUNDARY FOR WEAPONS / INTEL
ROOM 141. CONTRACTOR TO PROVIDE DIELECTRIC
BREAKS AS REQUIRED WHEN PENETRATING THE
SECURE AREA BOUNDARY.
9 GOVERNMENT TO RE-LABEL THE COMMUNICATIONS
OUTLETS IN ROOM 135 ONCE PATCHED TO
SUPPORT ALIS ADMINS.
10 GOVERNMENT SHALL PROVIDE REQUIRED
TELEPHONE.
REVISION DATE DESCRIPTION BY APPR'D
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
DATE
SIGNATURE
APPROVED
CENM
DRAWN BY
PROJ. ENGR.
CONTENTS
APPROVED
TITLE
DATE
SCALE
SHEET OF
SPEC. NO.
INDEX NO.
PROJ. NO. DRAWING NO. FILE NO.
96/CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
APPROVED
PROGRAM MANAGER
APPROVED
FIRE PREVENTION
APPROVED
SAFETY REPRESENTATIVE
APPROVED
DIR. BASE. MED. SERVICE
APPROVED
USING AGENCY
APPROVED
COMMUNICATIONS
APPROVED
OPERATIONS ENGINEERING
APPROVED
ENVIRONMENTAL
APPROVED
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
20AH FTFA20CB73
RENOVATE SQUADRON
OPERATIONS AREA JSF
HANGAR B1412
1/26/2021
T-111
TELECOM PARTIAL FLOOR PLAN SW
TBG
DMB
N
1/8" = 1'-0"T-111
1 NEW TELECOM PLAN SW
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
KEY PLAN
1 4/1/2021 REVISION 1
L L
BAGW
E
M.
LIC N
AVID
No. 59251
SD E
AL EN
S IO
R O
F
ES
P
N
STATE OF
G
IN
E E
R
E
SERVER ROOM
2019.8
F
T-501
T-501
T-501
434-A
UNCLASS
BLUE
434-B
434-G
BROWN
434-F
BLUE
434-E
LIGHT
BLUE
434-D
RED
434-C
YELLOW
11111
SERVER ROOM
2019.8
F
SERVER ROOM
2 2.2
F
T-502
REVISION DATE DESCRIPTION BY APPR'D
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
DATE
SIGNATURE
APPROVED
CENM
DRAWN BY
PROJ. ENGR.
CONTENTS
APPROVED
TITLE
DATE
SCALE
SHEET OF
SPEC. NO.
INDEX NO.
PROJ. NO. DRAWING NO. FILE NO.
96/CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
APPROVED
PROGRAM MANAGER
APPROVED
FIRE PREVENTION
APPROVED
SAFETY REPRESENTATIVE
APPROVED
DIR. BASE. MED. SERVICE
APPROVED
USING AGENCY
APPROVED
COMMUNICATIONS
APPROVED
OPERATIONS ENGINEERING
APPROVED
ENVIRONMENTAL
APPROVED
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
20AH FTFA20CB73
RENOVATE SQUADRON
OPERATIONS AREA JSF
HANGAR B1412
1/26/2021
T-401
TELECOM ENLARGED PLANS
TBG
DMB
TELECOM ENLARGED PLAN KEY NOTES:
1 FLOOR MOUNT LOCKABLE 4-POST COMMUNICATIONS RACK. GREAT
LAKES GL790ES-2442MS OR EQUAL. PROVIDE VERTICAL CABLE
MANAGEMENT, VCT-79 OR EQUAL. PROVIDE CABLE MANAGEMENT
COVER, VCT-79C OR EQUAL.
2 EXISTING LADDER TRAY.
1/2" = 1'-0"T-401
1 ENLARGED SERVER ROOM 434 EQUIPMENT PLAN
1/2" = 1'-0"T-401
2 ENLARGED SERVER ROOM 434 OVERHEAD TRAY PLAN
1/2" = 1'-0"T-401
ENLARGED SERVER ROOM 134 OVERHEAD
TRAY PLAN
1 4/1/2021 REVISION 1
L L
BAGW
E
M.
LIC N
AVID
No. 59251
SD E
AL EN
S IO
R O
F
ES
P
N
STATE OF
G
IN
E E
R
E
SERVER ROOM
2 2.2
F
T-502
T-502
134-A
UNCLASS
NIPR BLUE
134-B
UNCLASS
LM GREEN
134-C
SECURE LM
BLUE AND
LM RED
134-D SIPR
RED
1 3
EXISTING
RACK 3
EXISTING
RACK 2
2 2.2
F
SERVER ROOM
EXISTING
RACK 1
1 2
EXISTING
RACK 2
EXISTING
RACK 3
REVISION DATE DESCRIPTION BY APPR'D
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
DATE
SIGNATURE
APPROVED
CENM
DRAWN BY
PROJ. ENGR.
CONTENTS
APPROVED
TITLE
DATE
SCALE
SHEET OF
SPEC. NO.
INDEX NO.
PROJ. NO. DRAWING NO. FILE NO.
96/CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
APPROVED
PROGRAM MANAGER
APPROVED
FIRE PREVENTION
APPROVED
SAFETY REPRESENTATIVE
APPROVED
DIR. BASE. MED. SERVICE
APPROVED
USING AGENCY
APPROVED
COMMUNICATIONS
APPROVED
OPERATIONS ENGINEERING
APPROVED
ENVIRONMENTAL
APPROVED
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
20AH FTFA20CB73
RENOVATE SQUADRON
OPERATIONS AREA JSF
HANGAR B1412
1/26/2021
T-401A
TELECOM ENLARGED PLANS
Author
Approver
1/2" = 1'-0"T-401A
ENLARGED SERVER ROOM 134 EQUIPMENT
PLAN - NEW
1/2" = 1'-0"T-401A
ENLARGED SERVER ROOM 134 EQUIPMENT
PLAN - EXISTING
EXISTING ENLARGED PLAN KEY NOTES:
1 EMPTY LOCKABLE COMMUNICATION CABINET TO
BE MOVED AND UTILIZED FOR EXISTING NIPR. SEE
NEW WORK PLAN FOR NEW LOCATION.
2 EXISTING 4-POST RACK CONTAINING SIPR DROPS.
3 EXISTING 4-POST RACK WITH NIPR DROPS.
NEW ENLARGED PLAN KEY NOTES:
1 USE EXISTING LOCKABLE COMM CABINET TO HOUSE EXISTING 96 CS NIPR
ASSOCIATED EQUIPMENT (NIPR PATCH PANELS, TOP FIBER OPTIC
DISTRIBUTION PANEL, AND 2 EACH RECEPTACLE CIRCUITS) MOVED FROM RACK 3.
2 MOVE SIPR CABLES FROM THIS RACK AND INSTALL IN NEW PATCH PANEL IN WALL
MOUNTED RACK 4. LEAVE ALL OTHER CABLES/EQUIPMENT.
3 LEAVE REMAINING EQUIPMENT ITEMS IN THIS RACK AFTER RELOCATING THOSE
REQUIRED TO 96 COMM UNCLASS RACK. (REFER TO NOTE 1)
4 NEW WALL MOUNTED LOCKABLE CABINET FOR 96 COMM SIPR MODEL NUMBER
EWMWG362425 36" X 24" X 25" CABINET WITH WINDOW DOOR AND GLAND PLATE 19
RACK UNITS.
R A
C K
1 4/1/2021 REVISION 1
L L
BAGW
E
M.
LIC N
AVID
No. 59251
SD E
AL EN
S IO
R O
F
ES
P
N
STATE OF
G
IN
E E
R
E
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
1 2 3 4 5 6 7 8 9 10 11 12
34 35 36 37 38 39 40 41 42 43
13 14 15 16 17 18 19 20 21 22 23
44 45 46 47 48
25 26 27 28 29 30 31 32 33
134-A
BLUE
4RED NEW FIBER L.I.U.
134-D
REVISION DATE DESCRIPTION BY APPR'D
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
DATE
SIGNATURE
APPROVED
CENM
DRAWN BY
PROJ. ENGR.
CONTENTS
APPROVED
TITLE
DATE
SCALE
SHEET OF
SPEC. NO.
INDEX NO.
PROJ. NO. DRAWING NO. FILE NO.
96/CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
APPROVED
PROGRAM MANAGER
APPROVED
FIRE PREVENTION
APPROVED
SAFETY REPRESENTATIVE
APPROVED
DIR. BASE. MED. SERVICE
APPROVED
USING AGENCY
APPROVED
COMMUNICATIONS
APPROVED
OPERATIONS ENGINEERING
APPROVED
ENVIRONMENTAL
APPROVED
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
20AH FTFA20CB73
RENOVATE SQUADRON
OPERATIONS AREA JSF
HANGAR B1412
1/26/2021
T-502
RACK ELEVATIONS
TBG
DMB
1 1/2" = 1'-0"T-502
UNCLASS NETWORK RACK ELEVATION - COMM
ROOM 134
1 1/2" = 1'-0"T-502
CLASSIFIED NETWORK RACK ELEVATION -
COMM ROOM 134
RACK ELEVATION KEY NOTES:
1 EXISTING COMMUNICATIONS RACK.
2 EXISTING COPPER PATCH PANEL.
3 NEW WALL MOUNTED LOCKABLE CABINET FOR 96 COMM
SIPR MODEL NUMBER EWMWG362425 36" X 24" X 25"
CABINET WITH WINDOW DOOR AND GLAND PLATE 19 RACK
UNITS.
4 24 PORT SCREENED TWISTED PAIR (ScTP) CATEGORY 6
HORIZONTAL PATCH PANEL.
5 EXISTING FIBER L.I.U.
6 NEW FIBER L.I.U.
NOTE: ALL SIPR CABLES SHALL BE DISCONNECTED FROM
EXISTING UNCLASS CABINET PULLED BACK, REROUTED, AND
TERMINATED TO NEW PATCH PANEL IN CLASSIFIED WALL MOUNT
CABINET. NO CLASSIFIED CABLING SHALL REMAIN IN THE
EXISTING UNCLASS RACK (134-A)
1 4/1/2021 REVISION 1
L L
BAGW
E
M.
LIC N
AVID
No. 59251
SD E
AL EN
S IO
R O
F
ES
P
N
STATE OF
G
IN
E E
R
E
| Sheets |
| T-101 - TELECOM EXISTING PARTIAL PLAN SW |
| T-111 - TELECOM PARTIAL FLOOR PLAN SW |
| T-401 - TELECOM ENLARGED PLANS |
| T-401A - TELECOM ENLARGED PLANS |
| T-502 - RACK ELEVATIONS |
File details come from the government source that posted it. Updated .