This is a Standard Coating Specification document prepared by Southern Paint & Supply Co. for New Smyrna Beach Utilities, establishing uniform requirements for interior and exterior painting services across all municipal facilities. The specification defines mandatory coating systems for eight distinct substrate types, including previously painted masonry surfaces, non-ferrous metals, architectural metals, ferrous metals in high-performance areas, concrete floors, uncoated CMU block, rusty metal lintels, and interior walls and trim. All work must be performed at three locations: Central Office Building (200 Canal Street), South Beach Pump Station (4460 S. Atlantic Avenue), and Water Reclamation Facility (3119 SR 44). A mandatory pre-bid meeting is scheduled for 9:00 A.M. on Tuesday, May 26, 2026, at the Central Office Building, with site visits to all three locations. The specification explicitly prohibits spray application, sandblasting, and any substitutions or alternate products; all contractors must use only the specified materials and application methods to maintain bid consistency and warranty eligibility.
The document establishes a seven-year, non-prorated material warranty for exterior coating systems when applied in full compliance with specifications and manufacturer technical data sheets. All specified coating products are sourced from Benjamin Moore & Co. and INSL-X product lines, with detailed product numbers and application requirements for each substrate type. Contractors must maintain Florida licenses, proof of insurance, and compliance with OSHA regulations and manufacturer safety guidelines. The Owner reserves the right to conduct inspections at various project stages to verify proper surface preparation and application practices, and rejected work must be corrected at the contractor's expense. The specification emphasizes that no deviations from specified materials, preparation methods, or application procedures are permitted without prior written authorization from New Smyrna Beach Utilities, and any unauthorized changes may require removal and correction at contractor expense.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB_1326_Addendum_3.pdf | ||
| COB_3rd_Floor.pdf | ||
| ITB_1326_Addendum_2.pdf | ||
| ITB_1326_Addendum.pdf | ||
| ITB_13-26_Interior_&_Exterior_Painting_Services.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STANDARD COATING SPECIFICATION
Buildings, Structures, and Related Components
Prepared For: Robert Bryant – Fleet & Facilities Manager, New Smyrna Beach Utilities
Prepared by: Joe Tuttolomondo President, Southern Paint & Supply Co.
(386) 566-8004
Date Issued:
January 9, 2026
Table of Contents
PURPOSE
FINISH SCHEDULE - SYSTEMS BY SUBSTRATE
PREVIOUSLY PAINTED MASONRY SURFACES:
PREVIOUSLY PAINTED NON-FERROUS METAL & PLASTIC SURFACES
PREVIOUSLY PAINTED ARCHITECTURAL METAL SURFACES
FERROUS METAL – HIGH PERFORMANCE AREAS
PREVIOUSLY PAINTED CONCRETE FLOORS
UNCOATED CMU BLOCK
SPECIAL CONDITIONS - RUSTY METAL LINTELS
SPECIAL CONDITIONS - METAL AT CONCRETE SPALLS
INTERIOR WALLS
INTERIOR TRIM
WARRANTY & INSPECTIONS
TERMS AND CONDITIONS
A. CHANGES TO WORK
B. SUBSTITUTIONS AND ALTERNATES
C. LICENSING AND REGULATORY COMPLIANCE
D. INSURANCE
E. SAFETY AND JOBSITE CONTROL
F. QUALITY CONTROL AND RESPONSIBILITY
G. PRE-BID MEETINGS AND SITE VISITS
H. PROJECT-SPECIFIC CONDITIONS
DEFINITIONS
ENVIRONMENTAL CONDITIONS & APPLICATION LIMITS
SURFACE PROTECTION & DAMAGE RESPONSIBILITY
REJECTION, CORRECTION, AND ACCEPTANCE
APPENDIX A
FACILITY-SPECIFIC CONDITIONS
A. GENERAL FACILITY INFORMATION
C. INCLUDED SURFACES
D. EXCLUDED SURFACES
F. ACCESS, PHASING, AND OPERATIONAL CONSTRAINTS
H. ADDITIONAL FACILITY-SPECIFIC REQUIREMENTS
PURPOSE
New Smyrna Beach Utilities has established this Standard Coating Specification to define uniform requirements for surface preparation, coating materials, and application procedures for all buildings, structures, and related components. This document is intended to serve as the single governing coating standard for all facilities, replacing prior project or structure-specific specifications.
The purpose of this specification is to ensure:
• Consistent coating performance and appearance across all substrates
• Long-term durability, corrosion protection, and service life
• Proper surface preparation and application practices
• Clear accountability for contractors, material suppliers, and the Owner
All work shall be performed strictly in accordance with the written scope of this specification, the Finish Schedule, and the applicable manufacturer’s Technical Data Sheets (TDS). When properly applied, the specified coating systems are designed to meet or exceed the minimum service requirements for the environmental and operational conditions present at New Smyrna Beach Utilities facilities.
This specification has been developed with consideration given to environmental exposure, substrate conditions, preparation requirements, coating compatibility, film thickness, and overall system performance. These factors are critical to achieving coating integrity, longevity, and acceptable appearance.
To ensure consistency, quality control, and an equitable bidding process, no alternate, “equal,” or substitute products are permitted. Contractors are required to use only the coating materials specified herein, without exception. This requirement ensures that all bidders are pricing the same materials, all coatings are applied in accordance with proven systems, and the Owner receives the intended level of performance and protection.
This Standard Coating Specification is intended to:
• Establish a clear and enforceable baseline for all coating work
• Hold contractors accountable for proper preparation and application
• Provide material suppliers and inspectors with a definitive reference
• Protect the long-term interests of New Smyrna Beach Utilities
Compliance with this specification is mandatory for all coating work performed for New Smyrna Utilities.
FINISH SCHEDULE - SYSTEMS BY SUBSTRATE
The following tables establish the mandatory coa_ng systems for each substrate type governed by this Standard Coa_ng Specifica_on. The coa_ng systems iden_fied herein define the required surface prepara_on, coa_ng types, and applica_on methods to be used for all applicable work.
All coa_ngs shall be applied in strict accordance with this Standard and the applicable manufacturer’s Technical Data Sheets. No subs=tu=ons, alternates, or devia=ons are permi>ed.
Finish Schedule Contents
1. Previously Painted Masonry Surfaces
a. Concrete, Stucco, CMU Block – Ver_cal Surfaces
2. Previously Painted Non-Ferrous Metal & Plas_c Surfaces
a. Guders, Downspouts, Corrugated Metal, Conduit
3. Previously Painted Architectural Metal Surfaces
a. U_lity Doors, Frames, Electrical Boxes, Vents
4. Ferrous Metal – High Performance Areas
a. Steel Pipes, Supports, Railings, Catwalks
5. Previously Painted Concrete Floors
6. Uncoated CMU Block
7. Special Condi_ons - Rusty Metal Lintels
GLOBAL PROHIBITIONS (ALL SUBSTRATES)
- Spray applica_on of coa_ngs
- Sandblas_ng or abrasive blas_ng
- Use of alternate or "equal" products
- Applica_on outside manufacturer temperature or humidity limits
PREVIOUSLY PAINTED MASONRY SURFACES:
Surface Condition
Previously painted masonry surfaces only
Concrete, Stucco, CMU Block – Ver=cal Surfaces
Cleaning
Pressure wash to remove dirt, chalking, and loose coatings 3000psi or greater
Biological Growth
Treat mold and mildew with bleach wash or approved biocide
Zinsser Jomax House Cleaner
60101
Surface Preparation
Remove all loose, flaking, or blistered coa=ngs
Only =ghtly adhered, sound coa=ng leO behind.
Sealants
Remove and replace failed sealants with acrylic urethane sealant.
Allpro Pro Stretch Sealant
TS-13000
Primer / Sealer
ONE COAT: 100% Acrylic Masonry Sealer
Ben Moore Ultra Spec 608-00
Spot Priming
High-build acrylic waterproof direct-to-concrete coa=ng where necessary
Coronado Texcrete 3194-1
Base Coat ONE COAT: High-build acrylic waterproof direct-to-concrete coa=ng
Finish Coat
Exterior Satin Finish Paint
Coronado Cyrlicote House Paint
N410-1 Application Method
Brush and/or roller only Spray not permi[ed
Previously Painted Masonry Surfaces
Approved Biocide:
Jomax House Wash & Mildew Killer
Item number: 60101
Acrylic Urethane Sealant:
Allpro Pro Stretch
Item number: TS-13000
100% Acrylic Masonry Sealer:
Ultra-Spec Masonry Sealer
Item number: 608-00
High-Build Acrylic Waterproof CoaAng:
Texcrete Concrete Coa=ng
Item number: 3194-1
100% Acrylic Exterior Satin Finish Paint:
Crylicote 100% Acrylic House Paint
Item number: N410-1
Previously Painted Masonry Surfaces Examples:
PREVIOUSLY PAINTED NON-FERROUS METAL & PLASTIC SURFACES
Previously painted non-ferrous metal or plastic surfaces
Gu[ers, Downspouts, Corrugated Metal, Conduit chalking, and loose coatings, degrease as required
3000psi or greater biocide where necessary
Zinsser Jomax House Cleaner blistered coa=ngs. Light sanding to de-gloss exis=ng coa=ngs.
Only =ghtly adhered, sound coa=ng leO behind.
Acrylic bonding primer as required
INSL-X
STIX Primer
SXA-110
Coronado Cyrlicote House Paint
Previously Painted Non-Ferrous Metal & Plas8c Surfaces
Acrylic Bonding Primer:
INSL-X Stix
Item number: SXA-110
PREVIOUSLY PAINTED ARCHITECTURAL METAL SURFACES
Previously painted architectural metal surfaces
U=lity Doors, Frames, Electrical Boxes, Generator
Boxes, Bollards, Vents
Pressure wash to remove dirt, chalking, and loose coatings, degrease as required biocide where necessary
Zinsser Jomax House Cleaner blistered coa=ngs. Light sanding or abrasion to de-gloss exis=ng coa=ngs.
Hand tool cleaning per SSPC-
SP 2
ONE COAT: Acrylic DTM primer as required
Ben Moore HP DTM Primer
HP1100
TWO COATS: Acrylic Direct-to-Metal (DTM) Enamel
Ben Moore HP DTM Enamel
HP3310
Previously Painted Architectural Metal Surfaces
Acrylic Bonding Primer:
HP DTM Primer
Item number: HP1100
Semi- Gloss DTM Enamel:
HP DTM Enamel S/G
Item number: HP3310
Previously Painted Architectural Metal Surfaces
FERROUS METAL – HIGH PERFORMANCE AREAS
Previously painted ferrous metal surfaces
Steel pipes, supports, railings, catwalks
Degreasing
Citrus based cleaner degreaser
INSL-X
All-Purpose Citrus Cleaner
CL-0200
chalking, and loose coatings 3000psi or greater blistered coa=ngs.
Hand or power-tool cleaning per SSPC-SP 2 / SSPC-SP 3
Primer
ONE COAT: 100% Solids Epoxy Primer – 2 component
Ben Moore HP Concrete & Metal Epoxy
HP1550
Intermediate Coat
ONE COAT: Epoxy Mastic – 2 component
Ben Moore HP Epoxy Mas=c
HP4600
ONE COAT: Aliphatic urethane enamel - 2 component
Ben Moore HP Alipha=c Urethane
HP5000
Recoat Window Maximum 72 hours between coats
AOer 72 hours MUST abrade the surface to ensure proper inter-coat adhesion.
Ferrous Metal - High Performance Areas
Citrus Based Cleaner:
INSL-X All-Purpose Citrus Cleaner
Item number: CL-0200
100% Solids Epoxy Primer:
HP Concrete & Metal Primer
Item number: HP1550
Epoxy Mastic:
HP Epoxy Mastic
Item number: HP4600
AliphaAc Urethane:
HP Alipha=c Urethane
Item number: HP5000
Ferrous Metal - High Performance Areas
PREVIOUSLY PAINTED CONCRETE FLOORS
Previously painted concrete floors
Sidewalks, landings, entry/exit ways, etc.
Degreasing
Citrus based cleaner degreaser INSL-X All-Purpose Citrus Cleaner chalking, and loose coatings, 3000psi or greater blistered coa=ngs.
Hand tool, feather sand edges to eliminate transi=on
Texture Coat
Textured acrylic concrete coating. TWO COATS if no existing texture, ONE COAT if existing texture
INSL-X
Sure Step
NTS-311B
ONE COAT: Acrylic concrete waterproofing stain
INSL-X
Tuff Crete WB
CST2110
Previously Painted Concrete Floors
Citrus Based Cleaner:
INSL-X All-Purpose Citrus Cleaner
Item number: CL-0200
Textured Acrylic Concrete Coating:
INSL-X Sure Step
Item number: NTS311B
Acrylic Concrete Stain:
INSL-X Tuff Crete
Item number: CST2110
UNCOATED CMU BLOCK
Unpainted CMU block surfaces Sidewalks, landings, entry/exit ways, etc.
chalking, and loose coatings, degrease as required biocide where necessary
Zinsser Jomax House Cleaner
Allow to dry completely prior to coa=ng
ONE COAT: Invisible siloxane sealer
INSL-X
Mul=-Surface Waterproofer
WPS-1000
Invisible Siloxane Sealer:
INSL-X Tuff Crete
Item number: CST2110
Uncoated CMU Block
SPECIAL CONDITIONS - RUSTY METAL LINTELS
Heavily corroded, rusty window lintels Rusty metal lintels chalking, loose coatings, and rust blistered coa=ngs, remove all loose, scaling rust
Hand or power-tool cleaning per SSPC-SP 2 / SSPC-SP 3
Repairs Patch/fill deep divots with body filler
3M Bondo Body Filler
00265
Ben Moore HP Concrete & Metal Epoxy
Intermediate Coat
ONE COAT: Epoxy Mastic – 2 component
Ben Moore HP Epoxy Mas=c
HP4600
ONE COAT: Aliphatic urethane enamel - 2 component
Ben Moore HP Alipha=c Urethane
HP5000
Recoat Window Maximum 72 hours between coats AOer 72 hours MUST abrade the surface to ensure proper
Special Condi8ons - Rusty Metal Window Lintels
Body Filler:
3M Bondo Body Filler
Item number: 00265
Epoxy Mastic:
HP Epoxy Mastic
Item number: HP4600
AliphaAc Urethane:
HP Alipha=c Urethane
Item number: HP5000
SPECIAL CONDITIONS - METAL AT CONCRETE SPALLS
Spalling concrete Miscellaneous areas throughout facili=es.
chalking, loose coatings, rust, and concrete
Scrape loose, scaling rust, leave only =ghtly adhered rust Hand or power-tool cleaning
Repairs Depending on depthe of repair, patch/fill deep divots with appropriate filler
Could vary
Ben Moore HP Concrete & Metal Epoxy
HP1550
Recoat Window Maximum 72 hours to topcoat AOer 72 hours MUST abrade the surface to ensure proper
Spot Prime
High-build acrylic waterproof direct-to-concrete coa=ng where necessary
TWO COATS: 100% Acrylic
Coronado Cyrlicote House Paint
Special Condi8ons - Metal at Concrete Spalls
Body Filler:
3M Bondo Body Filler
Item number: 00265
High-Build Acrylic Waterproof CoaAng:
Texcrete Concrete Coa=ng
Item number: 3194-1
Special Condi8ons - Metal at Concrete Spalls
INTERIOR WALLS
Interior walls Drywall, plaster
Remove dirt, dust, grease, and contaminates Wipe walls
Light sanding to de-gloss glossy surfaces; patch and repair minor imperfec=ons
Match exis=ng surface texture
Caulk baseboards, moldings, corners, chair rails, etc., where necessary
Southern Supreme Sealflex Caulk
E110
Priming
Prime repaired or bare areas with acrylic primer
Mul=-Purpose Primer
067-00 Paint TWO COATS: Scuff resistant interior paint
SCUFF-X Eggshell
N485
Interior Walls
Caulk:
Southern Supreme Sealflex Caulk
Item number: E110
Acrylic Primer:
Ben Moore Mul=-Purpose Primer
Item number: 067-00
Scuff Resistant Paint:
Ben Eggshell
Item number: N626
INTERIOR TRIM
Interior trim & Doors Baseboards, moldings, chair rails, doors, handrails, etc.
Remove dirt, dust, grease, and contaminates
Pay special a[en=on to touch point, degrease to remove finger oils
Light sanding to de-gloss glossy surfaces; patch and repair minor imperfec=ons
Remove dust, spot prime patches
Caulk baseboards, moldings, corners, chair rails, etc., where necessary
Southern Supreme Sealflex Caulk
E110
Prime repaired or bare areas with acrylic primer
Mul=-Purpose Primer
067-00 Paint TWO COATS: Semi-gloss acrylic enamel
Multapply Enamel
Interior Trim
Caulk:
Southern Supreme Sealflex Caulk
Item number: E110
Acrylic Primer:
Ben Moore Mul=-Purpose Primer
Item number: 067-00
Semi-Gloss Acrylic Enamel:
Coronado Multapply Enamel
Item number: 1190-1
WARRANTY & INSPECTIONS
An evaluation of the facilities covered under this Standard Coating Specification has been conducted for the purpose of establishing uniform coating systems and performance expectations. This specification has been developed to achieve a seven (7) year, non-prorated material warranty for the exterior coating systems when applied in full compliance with this document and the manufacturer’s written instructions.
The Contractor shall be responsible for ensuring that all surface preparation, application methods, film thicknesses, cure times, and environmental conditions strictly conform to the requirements of this specification and the applicable Technical Data Sheets (TDS). Failure to comply with these requirements may result in loss of warranty coverage and may require corrective work at the Contractor’s expense.
A designated manufacturer’s representative shall have the right to inspect the work at various stages of the project, including but not limited to:
• Surface preparation
• Application of primers and intermediate coats
• Application of finish coats
These inspections are intended to help verify proper preparation and application practices and to support eligibility for the specified warranty. Such inspections do not relieve the Contractor of full responsibility for the quality and compliance of the work.
All products, systems, and warranties referenced herein are based solely on Benjamin Moore & Co. materials. No alternate manufacturers, products, or “equal” systems are permitted.
Warranty coverage shall apply only to materials supplied and applied in strict accordance with this specification. Any deviation from the specified products, preparation procedures, or application requirements—whether intentional or otherwise—shall void the warranty unless expressly approved in writing by New Smyrna Beach Utilities.
This Warranty & Inspection process is established to:
• Protect the long-term performance of the coating systems
• Ensure consistency and quality across all coated substrates
• Provide a clear framework for inspections and accountability
• Support enforceable warranty coverage for the Owner
TERMS AND CONDITIONS
The following Terms and Conditions apply to all coating work performed under this Standard Coating Specification at facilities owned or operated by New Smyrna Beach Utilities, unless modified by written special conditions specific to an individual facility.
These provisions establish baseline requirements for contractor responsibility, compliance, and project administration and are intended to apply uniformly across all facilities.
A. CHANGES TO WORK
1. This Standard Coating Specification defines the minimum acceptable requirements for coating work. Contractors shall not deviate from the specified materials, surface preparation methods, or application procedures without prior written authorization from New Smyrna Beach Utilities.
2. Any changes to the scope, materials, or procedures established by this Standard shall be initiated only by the Owner and issued in writing as a change directive, work order, or project-specific amendment.
3. Unauthorized changes, substitutions, or deviations shall not be accepted and may require removal and correction at the Contractor’s expense.
B. SUBSTITUTIONS AND ALTERNATES
1. No substitutions, alternates, or “or equal” products are permitted under this Standard Coating Specification.
2. All coating materials, systems, and application requirements are mandatory and shall be used exactly as specified.
3. Requests for alternate materials shall not be considered unless explicitly allowed under a written, Owner-issued exception applicable to a specific facility or project.
C. LICENSING AND REGULATORY COMPLIANCE
1. Contractors shall maintain all required licenses, certifications, and registrations necessary to perform coating work in the State of Florida and within the applicable jurisdiction.
2. Contractors shall comply with all applicable federal, state, county, and local laws, codes, and regulations related to the performance of the work.
D. INSURANCE
1. Contractors shall meet all insurance requirements established by the City of New Smyrna Beach and New Smyrna Beach Utilities for the applicable project.
2. Proof of required insurance shall be provided prior to commencement of work and maintained for the duration of the project.
E. SAFETY AND JOBSITE CONTROL
1. Contractors shall comply with all OSHA regulations, facility-specific safety requirements, and manufacturer safety guidance for materials used.
2. Contractors are responsible for maintaining safe work areas, including appropriate barricades, signage, and access controls, to protect personnel, the public, and facility operations.
3. The Owner reserves the right to suspend work if unsafe conditions or practices are observed.
F. QUALITY CONTROL AND RESPONSIBILITY
1. Contractors are solely responsible for the quality and compliance of all work performed under this Standard, regardless of inspections or observations by the Owner or manufacturer representatives.
2. Inspections conducted by the Owner or manufacturer representatives do not relieve the Contractor of responsibility for proper preparation, application, or adherence to this specification.
G. PRE-BID MEETINGS AND SITE VISITS
1. New Smyrna Beach Utilities may require mandatory pre-bid meetings or site visits for individual projects governed by this Standard.
2. When required, attendance shall be mandatory and may be a condition of bid acceptance.
H. PROJECT-SPECIFIC CONDITIONS
1. Facility-specific requirements, exclusions, or special conditions—including but not limited to access limitations, prohibited methods, included or excluded surfaces, or operational constraints—shall be addressed in a separate project-specific section.
DEFINITIONS
For the purposes of this Standard Coating Speci4ication, the following de4initions shall apply:
| • Previously | Painted | ||||||||||||||
| A | surface | that | has | been | coated | with | one | or | more | paint | or | coating | systems | prior | to |
| the | work | governed | by | this | Standard. |
| • Uncoated | / | Unpainted | |||||||||
| A | surface | that | has | not | previously | received | any | paint | or | coating | system. |
| • Masonry | Surfaces | |||||||
| Concrete, | stucco, | CMU | block, | cast-in-place | concrete, | and | similar | cementitious |
substrates.
| • Ferrous | Metal | |||||||||
| Iron-containing | metals, | including | carbon | steel | and | other | steel | substrates | subject | to |
corrosion.
| • Non-Ferrous | Metal | ||||||||||
| Metals | that | do | not | contain | iron, | including | aluminum, | galvanized | steel, | and | similar |
substrates.
| • Architectural | Metal | ||||||||
| Previously | painted | metal | components | such | as | doors, | frames, | electrical | enclosures, |
| vents, | fascia, | and | similar | non-structural | elements. |
| • High-Performance | Areas | |||||||||
| Ferrous | metal | substrates | exposed | to | aggressive | service | conditions, | including | but | not |
| limited | to | piping, | pipe | supports, | railings, | catwalks, | and | structural | supports | requiring |
| industrial-grade | coating | systems. |
• Contractor
| The | individual | or | 4irm | responsible | for | furnishing | labor, | materials, | equipment, | and |
| supervision | required | to | perform | coating | work | under | this | Standard. |
• Owner New Smyrna Beach Utilities or its authorized representative.
ENVIRONMENTAL CONDITIONS & APPLICATION LIMITS
| All | surface | preparation | and | coating | application | shall | be | performed | in | strict | accordance |
| with | the | applicable | manufacturer’s | Technical | Data | Sheets | (TDS) | for | each | product | used. |
| The | Contractor | is | solely | responsible | for | verifying | that: |
| • Ambient | temperature, | substrate | temperature, | and | humidity | conditions | are | within |
| manufacturer-recommended | limits |
| • Substrates | are | clean, | dry, | and | suitable | for | coating | |
| • Recoat | windows, | cure | times, | and | drying | requirements | are | met |
| Failure | to | comply | with | manufacturer | TDS | requirements | may | result | in | rejection | of | work | and |
| loss | of | warranty | eligibility. |
SURFACE PROTECTION & DAMAGE RESPONSIBILITY
| The | Contractor | shall | take | all | necessary | precautions | to | protect | adjacent | surfaces, | equipment, |
| structures, | and | property | from | damage, | contamination, | or | coating | materials | during | the | |
| performance | of | the | work. | ||||||||
| The | Contractor | shall | be | fully | responsible | for: |
| • Protecting | surrounding | surfaces | and | equipment | not | scheduled | for | coating |
| • Preventing | coating | materials | from | contacting | sensitive | equipment | or | operational |
components
• Promptly cleaning any unintended coating application or contamination
| Any | damage | caused | by | the | Contractor | or | their | operations | shall | be | repaired | or | replaced | at |
| the | Contractor’s | expense | to | the | satisfaction | of | the | Owner. |
REJECTION, CORRECTION, AND ACCEPTANCE
| All | coating | work | performed | under | this | Standard | is | subject | to | inspection | by | the | Owner | or |
| the | Owner’s | authorized | representative. |
Work may be rejected for any of the following reasons, including but not limited to:
| • Use | of | unapproved | materials | |||||||
| • Inadequate | surface | preparation | ||||||||
| • Improper | application | methods | ||||||||
| • Failure | to | comply | with | this | Standard | or | manufacturer | Technical | Data | Sheets |
| Rejected | work | shall | be | corrected | or | replaced | at | the | Contractor’s | expense, | including | all |
| labor | and | materials, | and | shall | be | re-inspected | prior | to | acceptance. |
Acceptance of the work shall occur only after:
| • All | speci4ied | work | has | been | completed | in | compliance | with | this | Standard |
| • Any | rejected | items | have | been | satisfactorily | corrected | ||||
| • The | Owner | has | issued | acceptance | of | the | work |
| Inspections, | observations, | or | acceptance | by | the | Owner | do | not | relieve | the | Contractor | of |
| responsibility | for | compliance | with | this | Standard | or | for | warranty | obligations. |
APPENDIX A
FACILITY-SPECIFIC CONDITIONS
This Appendix identifies project- or facility-specific requirements, restrictions, inclusions, and exclusions applicable to coating work performed under the New Smyrna Beach Utilities Standard Coating Specification.
Unless expressly stated herein, all work shall comply fully with the requirements of the Standard Coating Specification.
Facility-specific conditions shall supplement, but not override, the Standard unless explicitly noted.
A. GENERAL FACILITY INFORMATION
• Facility Name: ______________________________
• Facility Address: ___________________________
• Owner’s Representative: _____________________________
• Project Reference / Bid No.: ___________________________
C. INCLUDED SURFACES
The following surfaces are included for coating under this Appendix:
D. EXCLUDED SURFACES
The following surfaces are excluded from the Scope of Work unless otherwise authorized in writing:
F. ACCESS, PHASING, AND OPERATIONAL CONSTRAINTS
The Contractor shall coordinate all work with the Owner to accommodate facility operations.
☐ Restricted access areas ☐ Work hours limited to: ________________________ ☐ Phased work required ☐ Shutdown coordination required
Additional constraints (if any):
H. ADDITIONAL FACILITY-SPECIFIC REQUIREMENTS
List any additional conditions, clarifications, or requirements unique to this facility:
TECHNICAL DATA JMX-08
JOMAX® HOUSE CLEANER
AND MILDEW KILLER
1 Form: GDH-169 Rev.: 062123
DESCRIPTION AND USES
JOMAX® House Cleaner and Mildew Killer is a mildewcidal liquid house washing concentrate formulated to kill mold and mildew and remove dirt and stains on most exterior painted or non-porous surfaces without the need for scrubbing.
Jomax House Cleaner and Mildew Killer is an EPA approved, patented concentrate containing a mildewcide, ChlorRelease® bleach activator and detergents. When used as directed, Jomax will not damage painted surfaces and may be applied near plants and shrubs. It is recommended for cleaning vinyl and aluminum siding and trim, painted or stained wood siding, trim, decks, fences, and painted or stained stucco, concrete and other painted or non-painted surfaces.
PERFORMANCE CHARACTERISTICS
• Kills mold & mildew fast
• Removes dirt and stains without scrubbing
• Can be used near plants and shrubs
• Easy application with a garden sprayer
PRODUCTS
SKU DESCRIPTION
60101 1 Gallon
60104 1 Quart
PRODUCT APPLICATION
IMPORTANT
This product is for outdoor use only. Test on inconspicuous area before applying to ensure favorable results. Wear old clothes and shoes, eye protection and rubber gloves during use. Do not mix with any other chemicals or cleaners as hazardous fumes may occur.
PREPARATION
Spray all surrounding plants and vegetation liberally with water before and after application. Cover delicate vegetation to avoid damage. Do not allow Jomax House Cleaner and Mildew Killer to come in contact with fabrics.
PRODUCT APPLICATION (cont.)
MIXING INSTRUCTIONS
Shake well before using. Mix in the proper proportions with bleach and water (80% water, 15% bleach, and 5% Jomax) according to the label directions and chart below. To ensure that components are properly mixed, follow mixing chart to produce the desired quantity of cleaning solution.
Water + Bleach + Jomax = Cleaning Solution
3 ¼ Qts. 2 ¼ Cups ¾ Cups 1 Gal.
6 ½ Qts. 4 ½ Cups 1 ½ Cups 2 Gal.
4 Gal. 3 Qts. 1 Qt. 5 Gal.
Pour water into a tank-type garden sprayer or plastic pail.
Add household bleach (Chlorox®) to the water. Shake Jomax House Cleaner and Mildew Killer concentrate thoroughly and then add the concentrate to the solution.
IMPORTANT
Follow manufacturer’s precautions when using bleach. Use immediately after mixing. The prepared Jomax solution remains effective for 3 hours after mixing. Do not allow solution to contact fabrics. Mixture may be applied in areas adjacent to plants, shrubs and trees.
APPLICATION
Apply with a tank-type garden sprayer, airless or chemical sprayer. Spray surfaces liberally and wait 5 minutes.
Thoroughly rinse the treated surfaces and surrounding areas with large amounts of water. Heavy mildew stains may require a second application. Textured surfaces may require light scrubbing. For best results, rinse surfaces with a pressure washer (follow manufacturer’s instructions for tip size and pressure setting). As a precaution, spray sensitive plants with water before and after Jomax application.
CLEAN-UP
Clean sprayer with water and baking soda or a non-ammonia cleaner.
STORAGE AND DISPOSAL
Protect from freezing. Always keep the container tightly closed and store in a cool dry place at temperatures between 40-80°F (4-27°C). Product may discolor during storage. Color changes do not affect product performance.
Dispose of container and unused contents in accordance with federal, state and local requirements.
TECHNICAL DATA JMX-08
JOMAX® HOUSE CLEANER
AND MILDEW KILLER
Rust-Oleum Corporation
11 Hawthorn Parkway Vernon Hills, Illinois 60061
Phone: 888∙855∙1774 www.rustoleum.com
Form: GDH-170
Rev.: 062123
PHYSICAL PROPERTIES
HOUSE CLEANER AND MILDEW KILLER
Composition Acetic Acid, Surfactants, Water
Weight Per Gallon 8.33 lbs.
Per Liter 1.00 kg pH NA
VOC 170 g/l
Practical Coverage 1 quart Jomax makes 5 gallons of solution, treats 1,000 square feet
Shelf Life 5 years
Flash Point >200ºF (93ºC)
Caution!
Harmful if swallowed. Avoid contact with skin, eyes and clothing. Avoid breathing vapors or spray mist. Protective goggles and gloves should be worn. Do not use in confined areas without proper ventilation. Avoid applications during windy conditions. KEEP OUT
OF REACH OF CHILDREN.
Safety Information For additional information, see SDS
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.
Technical Bulletin
ALLPRO® Corporation Tampa, FL 33619
Pro Stretch
AP7780 - 13000
Oct. 2021
Description PRO STRETCH™ is a one component, high performance, gun-grade, Acrylic Urethane Elastomeric Sealant. Formulated from premium technology, reduces dirt pickup, eliminates yellowing and shiners. Internally plasticized resin requires no mixing or priming to bond to most materials, including concrete, wood and masonry.
PRO STRETCH™ offers superior adhesion and durability, 50% total joint movement and 800% elongation. PRO STRETCH™ is safe for UV exposure, will not discolor and forms an airtight, water resistant seal, once cured the bead is mildew resistant. Can be used for interior or exterior applications.
Prominent Features Exceeds ASTM C-920, Grade NS, Class 25
Exceeds ASTM C-834, Type OP, Grade -18°C
Exceeds Fed. Spec TTS-00230C, Type II, Class A
Uses Caulks and Seals:
Expansion Joints Up to 2-1/2"
For Interior or Exterior Use Siding: Wood, Vinyl, Aluminum Surfaces -
Cement, Concrete, Hardboard Trim Curtain Wall Construction
Stucco
Panel Walls
Precast Units
Window & Door Installation
Fascia
Parapets
Limitations Not intended for under water use. Not for use on food contact areas. Keep from freezing.
Application Pro Stretch™ comes ready to use. U-shaped joints should have the proper size backer rod or bond breaker tape installed to prevent 3 point adhesion. The sealant must reach deepest point of the joint. Remove excess with a clean rag and water.
Tooling the joint flush with a putty knife is recommended. Tooling results in the correct bead shape, a neat joint, and maximum adhesion. 90° joints can be tooled smooth with a moistened rag to a minimum bead size of 3/8”.
Clean Up Clean all equipment with warm, soapy water immediately after use. Remove cured sealant by cutting with a sharp-edged tool. Remove thin films by abrading.
Disposal Contains organic solvents which may cause adverse effects to the environment if disposed of improperly. Contact your local sanitation department or household hazardous waste coordinator for information concerning possible reuse or disposal of unused solvent-containing adhesives and/or sealants. All material must be disposed in accordance with Federal, State, and Local Regulations.
Caution Technical Information
Do not take internally.
WARNING! CAUSES EYE, SKIN AND RESPIRATORY TRACT IRRITATION.
MAY BE HARMFUL IF SWALLOWED. CONTAINS ETHYLENE GLYCOL WHICH
CAN CAUSE SEVERE KIDNEY DAMAGE WHEN INGESTED AND HAS BEEN
SHOWN TO CAUSE BIRTH DEFECTS IN LABORATORY ANIMALS.
POTENTIAL CANCER HAZARD. USE ONLY WITH ADEQUATE VENTILATION.
KEEP OUT OF REACH OF CHILDREN.
NOTICE: This product contains solvents. Reports have associated repeated and prolonged overexposure to solvents with permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. For emergency information call ChemTrec at 800-424-9300. For additional safety information, refer to the Material Safety Data Sheet for this product. Obtain professional advice before using. Close container after each use.
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Safety Data Sheets (SDS) available upon request. Similar information for solvents and other chemicals used with ALLPRO products should be obtained from your supplier(s). When solvents are used, proper safety precautions must be observed.
FIRST AID: In case of skin contact, wash off quickly with plenty of soap and water, remove contaminated clothing. For eye contact flush eyes immediately with large quantities of water, for at least 15 minutes. Obtain emergency medical treatment. If swallowed, obtain medical treatment immediately. DO
NOT INDUCE VOMITING. If inhalation causes physical discomfort, remove to fresh air. If discomfort persists or any breathing difficulty occurs, get medical help.
Manufactured For:
ALLPRO® Corporation
Tampa, FL 33619
Note: The information, ratings and opinions stated above pertain to the material currently offered and represent the results of tests and calculations believed to be reliable.
Packaging: 10.1 fluid ounce cartridges.
Color: White, Clear, Off White, Limestone, Tan, Stone, Aluminum Gray, Redwood Tan, Bronze, Almond, Woodtone, Black and Redwood
Weight per Gallon: 9.3 ± 0.5
Solids: Approximately 70%
Coverage: 10.1 fl. oz.; 53 linear ft. at a 3/16" bead Shelf
Life: 24 months when stored at 50°F to 80°F Freeze Thaw
Stability: Passes 5 cycles @ 0°F (1 cycle = 16 hrs.@ 0°F, 8 hrs. @ 75°F)
Dynamic Joint Movement: Approximately ± 25%
Tack Free Time: 60 minutes
Tooling Time: 15 minutes
Full Cure: 7-14 Days - cure time @ 75°F ( 24°C) 50% relative humidity - joint size 1/2" x 1/4"
Paint Over Time: 4 to 6 hours Extrusion Rate: 20-25 Grams/Second @ 75°F Applications: Interior / Exterior
Warranty: Lifetime Performance
Odor: Mild Sweet Acrylic
Vehicle: Proprietary Urethane/Modified Acrylic Blend
(Siliconized)
VOC Content: Non-Chemically Curing Compound <1.5% less exempt solvents
Service Temperature: -40°F to 180°F Application Range:
40°F and rising.
Temperature Application Range: 40°F and rising. Air temp no hotter than 95° and substrate not hotter than 120°F
Analysis:
Acrylic Polymer: Proprietary
White Mineral Oil: 8024-47-5
Mineral Spirits: 8052-41-3
Calcium Carbonate: 471-34-1
Ethylene Glycol: 107-21-1
Quartz (SiO2): 14808-60-7
Contents Partially Unknown
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 608 US 052220
ULTRA SPEC®
MASONRY INTERIOR/EXTERIOR
100% ACRYLIC SEALER 608
Features General Description
Reduces the porosity of masonry surfaces.
Provides excellent surface adhesion.
Tintable.
High alkali resistant – up to pH-13.
Ultra Spec® Masonry Interior/Exterior 100% Acrylic Sealer is designed to penetrate and seal the surface of new or previously painted masonry surfaces providing the proper foundation for subsequent finish coats. It can be applied to masonry and plaster surfaces with pH levels as high as 13.
Recommended For Limitations
For commercial and residential applications
For application to new or previously painted masonry and plaster surfaces including; tilt-up concrete construction, stucco surfaces and block construction.
Do not apply when air and surface temperatures are below 50 °F (10 °C).
Product Information
Colors — Standard:
White (01), Clear (00)
(White may be tinted with up to 2.0 fl. oz. of Benjamin Moore® Gennex® colorants per gallon.)
Technical Data White
Vehicle Type 100% Acrylic Latex
Pigment Type N/A
Volume Solids 17.8%
Coverage per Gallon at Recommended Film Thickness
200 – 400 Sq. Ft.
Recommended Film Thickness
– Wet 5.3 mils
– Dry 0.95 mils
Depending on surface texture and porosity. Be sure to estimate the right amount of paint for the job. This will ensure color uniformity and minimize the disposal of excess paint.
Dry Time @ 77 °F
(25 °C) @ 50% RH
– To Touch 1 Hour
– To Recoat 4 Hours
Painted surfaces can be washed after two weeks. High humidity and cool temperatures will result in longer dry, recoat and service times.
Dries By Evaporation, Coalescence
Viscosity 94 ± 2 KU
Flash Point None
Gloss / Sheen Semi-Gloss (45 - 65 @ 60°) Gloss/Sheen will vary due to surface texture and porosity
Surface Temperature at Application
– Min. 50 °F
– Max. 90 °F
Thin With Clean Water
Clean Up Thinner Clean Water
Weight Per Gallon 8.5 lbs
Storage Temperature
– Min. 40 °F
– Max. 90 °F
Volatile Organic Compounds (VOC)
46 Grams/Liter .67 Lbs./Gallon
— Tint Bases:
Not available
— Special Colors:
Contact your Benjamin Moore representative
Certifications & Qualifications:
VOC compliant in all regulated areas
Qualifies for LEED® v4 Credit
Qualifies for CHPS low emitting credit (Collaborative for High Performance Schools)
CDPH v1 Emission Certified
Master Painters Institute MPI # 3, 3 X-GreenTM
Water vapor permeance (breathability) ASTM D1653: 46.5 Perms
Technical Assistance Available through your local authorized independent Benjamin Moore retailer.
For the location of the retailer nearest you, call 1-866-708-9180 or visit www.benjaminmoore.com
◊ Reported values are for White. Contact Benjamin Moore for values of other bases or colors http://www.benjaminmoore.com/
Ultra Spec® Masonry Interior / Exterior 100% Acrylic Sealer 608
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: (201) 573-9600 Fax: (201) 573-9046 www.benjaminmoore.com M72 608 US 052220 Benjamin Moore, Gennex, Ultra Spec and the triangle “M” symbol are registered trademarks, licensed to Benjamin Moore & Co. All other marks are the property of their respective owner. This product is not endorsed by or a division of CHPS. This product is provided by Benjamin Moore, not CHPS.
© 2016, 2018 Benjamin Moore & Co. All rights reserved
Surface Preparation
Surface must be dry, clean, and sound; free of chalk, peeling paint, form oils, efflorescence, and mildew. Remove chalk, surface deposits, and loose or scaling paint by scraping, sanding, and preferably power washing.
Glossy areas should be dulled. Un-weathered areas must be power washed or scrubbed with a detergent solution and rinsed to remove surface salts that can interfere with adhesion. Loose, sandy masonry should be hosed down thoroughly to remove surface particles and allowed to dry.
For masonry that has been allowed to cure for a minimum of 7 days under normal drying conditions and has a pH of 13 or less may be sealed with Ultra Spec® Masonry Interior/Exterior 100% Acrylic Sealer (608) prior to finishing.
A common exterior paint failure on masonry construction is peeling and scaling, often caused by painting over chalk deposits. The most practical and efficient way to remove this substance is by power washing. Multiple coats of paint that are in an advanced state of deterioration or prior applications of cement based coatings must be removed to a sound substrate.
WARNING! If you scrape, sand or remove old paint, you may release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST
CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE,
ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD
ALSO AVOID EXPOSURE. Wear a NIOSH-approved respirator to control lead exposure. Carefully clean up with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Information Hotline at 1- 800-424-LEAD or log on to www.epa.gov/lead.
Primer/Finish Systems
New surfaces should be fully primed, and previously painted surfaces may be primed or spot primed as necessary.
Rough or Pitted Masonry:
Primer: Ultra Spec ® Masonry Interior/Exterior 100% Acrylic Sealer (608) Finish: Appropriate Benjamin Moore® exterior house paint, or use Ultra Spec® Masonry Elastomeric Waterproof Coating - Low Lustre (360), Flat (359)
Smooth Poured or Precast Concrete & Fiber Cement Siding:
Primer: Ultra Spec® Masonry Interior/Exterior 100% Acrylic Sealer (608) Finish: Appropriate Benjamin Moore® exterior house paint, or use Ultra Spec® Masonry Elastomeric Waterproof Coating — Low Lustre (0360) or Flat (0359)
Cured Plaster:
Primer: Ultra Spec® Masonry Interior/Exterior 100% Acrylic Sealer (608) Finish: Appropriate Benjamin Moore® finish coat
Repaint, All Substrates: Prime bare areas with the primer recommended for the substrate above.
Application
Do not apply when air and surface temperatures are below 50 °F (10 °C).
Brush: Stir thoroughly and apply generously as received in the container with a good quality synthetic brush. Work into crevices to ensure adequate penetration and sealing.
Roller: Stir thoroughly and apply generously as received in the container with a good quality long-nap roller. Work into crevices to ensure adequate penetration and sealing.
Spray, Airless: Fluid Pressure — 1,000 to 2,000 PSI;
Tip—.013–.017 Orifice
Thinning/Clean up
Thinning is unnecessary, but if required to obtain desired application properties, a small amount of clean water may be added. Never add other paints or solvents. Clean up with warm soapy water. Spray equipment should be given a final rinse with mineral spirits to prevent rusting.
USE COMPLETELY OR DISPOSE OF PROPERLY. Dry, empty containers may be recycled in a can recycling program. Local disposal requirements vary; consult your sanitation department or state-designated environmental agency for more information on disposal options.
Environmental, Health & Safety Information
Use only with adequate ventilation. Do not breathe spray mist or sanding dust. Ensure fresh air entry during application and drying. Avoid contact with eyes and prolonged or repeated contact with skin. Avoid exposure to dust and spray mist by wearing a NIOSH approved respirator during application, sanding and clean
up. Follow respirator manufacturer’s directions for respirator use.
Close container after each use. Wash thoroughly after handling.
WARNING Cancer and Reproductive Harm– www.P65warnings.ca.gov
FIRST AID: In case of eye contact, flush immediately with plenty of water for at least 15 minutes; for skin, wash thoroughly with soap and water. If symptoms persist, seek medical attention. If you experience difficulty breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.
WARNING: This product contains isothiazolinone compounds at levels of <0.1%. These substances are biocides commonly found in most paints and a variety of personal care products as a preservative. Certain individuals may be sensitive or allergic to these substances, even at low levels.
IN CASE OF SPILL: — Absorb with inert material and dispose of as specified under “CleanUp”.
KEEP OUT OF REACH OF CHILDREN
PROTECT FROM FREEZING
Refer to Safety Data Sheet for additional health and safety information http://www.epa.gov/lead http://www.p65warnings.ca.gov/
TEXCRETE®
Masonry Waterproof Coating
Smooth Finish W3194
Manufactured by Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: 866-08-9180 www.coronadopaint.com W3194 US 100224
General Description Coronado® Texcrete® Waterproofers are high build, breathable waterproofing coatings, designed for application by the professional contractor to above grade concrete and masonry structures. These coatings are specifically engineered to be applied direct to concrete and masonry surfaces without priming.
Texcrete® coatings are designed to resist high pH surfaces and therefore can be applied direct to new concrete without extended curing and delays. These coatings pass the ASTM D6904 wind driven rain test and are resistant to salt spray, acid rain and UV light tested in 1 pinhole-free coat.
• High Alkali-Resistance
• Durable
• High Build
Usage Use on exterior vertical masonry substrates in exposures ranging from mild atmospheric to extreme weathering and wind-driven rain. These products may be applied to cured or uncured (green) concrete (minimum cure 10 days). No need to wait the required 28 day for concrete to cure.
Colors White (1) Bases Deep Base (34), Accent Base (36) Colorant System Gennex®
Technical Data Vehicle Acrylic Pigment Titanium Dioxide Volume Solids 40 ± 2% Spread Rate Per Gallon 90 – 110 Sq. Ft.
Recommended Film Thickness
Wet: 14.6 – 17.8 mils Dry: 5.8 – 7.1 mils
Depending on surface texture and porosity. Be sure to estimate the right amount of paint for the job.
This will ensure color uniformity and minimize the disposal of excess paint.
Dry Time @ 77 °F
(25 °C) @ 50% RH
To Touch: 1 hour To Recoat: 4 hours
High humidity and cool temperatures will result in longer dry, recoat and service times.
Surface Temperature During Application
Min: 35 °F Max: 100 °F
Viscosity 117 ± 4 KU Flash Point None Sheen / Gloss 0 – 5 @ 60° Clean Up Warm, soapy water Thinner Clean water Weight Per Gallon 11.5 lbs.
Storage Temperature Min: 40 °F Max: 95 °F
VOC < 100 g/L
New, Uncoated Surfaces: Must be free of dirt, dust, oil, grease, wax, form release, curing compounds or other debris that may affect penetration and adhesion. Remove efflorescence, laitance, chalk another contaminants utilizing industry accepted standards. Surface projections, mortar spatter and other protrusions should be removed by grinding or scraping. Mortar joints should be raked. Large "bug holes" or gravel pocks should be filled with mortar, or cementitious patching materials and allowed to cure before continuing. Damp masonry surfaces may be coated, however, no visible signs of water should be present on the surface.
Previously Coated Surfaces: Must be dry and free of dirt, dust, chalk, and other contaminants which may interfere with adhesion. Remove these by pressure washing with adequate pressure and water movement to ensure complete removal of contaminants. Loose or failing previous coating should be removed back to the point of sound adhesion. Existing coatings should be checked for compatibility with Coronado® Texcrete® WB Waterproofers by the application of a test patches.
WARNING! If you scrape, sand, or remove old paint, you may release lead dust. LEAD IS TOXIC. EXPOSURE
TO LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH
AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN.
PREGNANT WOMEN SHOULD ALSO AVOID
EXPOSURE. Wear a NIOSH approved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Informational Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead.
Limitations
• Water resistance requires two, pinhole-free coats by following label and TDS recommendations for application, priming, and recoat time.
• Not recommended for immersion service.
Compliance & Certifications
FEDERAL
OTC
OTC II
CARB
CARB07
CARB19
UTAH
AZMC
SCAQMD
ASTM D6904
Wind Driven Rain Pass: (< 0.2)
ASTM D2370 Elongation & Tensile Strength
42 %
407 PSI
ASTM D1653 Method B Water Vapor Permeance 12.8 perms
ASTM D3273/D3274
Mildew Resistance Test Pass: No Growth
ASTM D522/522M
Flexibility
Pass: No Cracking
ASTM D543
Alkali Resistance Pass
ASTM D 7072
Evaluation of Efflorescence Pass
Available through your local authorized independent Benjamin Moore retailer.
call 1-866-708-9180 visit www.benjaminmoore.com http://www.coronadopaint.com/
TEXCRETE® Masonry Waterproof Coating Smooth Finish W3194
Manufactured by Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: 866-08-9180 www.coronadopaint.com W3194 US 100224 ©2024 Benjamin Moore & Co. All trademarks belong to their respective owners. All rights reserved
Application Cracks, voids, transitions, changes of angle and junctions or dissimilar materials should be cleaned, primed with Coronado® Acrylic Masonry Sealer and then patched with a high-quality patching compound or acrylic urethane sealant, and these materials should be allowed to completely dry. Failing mortar joints should be replaced and tuck-pointed with new mortar. Large "bug holes" or gravel pocks should be filled with mortar or cementitious patching materials and allowed to cure before continuing.
Stir product thoroughly prior to use. Apply product by spray, or roller (for smaller areas) to be determined by job conditions, size and applicator preference.
Spray: Best accomplished by using a pump capable of spraying textured materials, such as the Graco® TexSpray RTX, or similar, with a 6mm nozzle.
NOTE: Textured product may experience packing in commercially available airless tips. If this occurs, apply by hopper type gun or power roller.
Sprayed finishes must be knocked off using a 3/4" to 1" lambs wool cover or loop roller to ensure uniform coverage. Knock Off is best accomplished in vertical passes down the wall, lifting the roller away from the wall at the end of each downward stroke.
Roller: Apply in 2 cross hatch coats (perpendicular to one another), utilizing a 1-1 ½” cover. Apply 9 to 10 mils wet per coat. Follow drying schedule listed in Technical Data Table above before applying second coat. A typical system is either two coats of the same texture or on porous masonry (such as CMU or split faced) one coat of smooth or sand finish, followed by the desired texture finish coat(s). Waterproofing systems require all coats to be pinhole-free for best results.
Thinning: Not required, however in hot weather, thin sparingly with water.
Clean Up Wash brushes, rollers, and other painting tools in warm soapy water immediately after use. Spray equipment should be given a final rinse with mineral spirits to prevent rusting.
USE COMPLETELY OR DISPOSE OF PROPERLY. Dry, empty containers may be recycled in a can recycling program. Local disposal requirements vary; consult your sanitation department or state-designated environmental agency on disposal options.
Environmental Health & Safety Information Use only with adequate ventilation. Do not breathe vapors, spray mist or sanding dust. Ensure fresh air entry during application and drying. Avoid contact with eyes and prolonged or repeated contact with skin. Avoid exposure to dust and spray mist by wearing a NIOSH approved respirator during application, sanding and clean up. Follow respirator manufacturer’s directions for respirator use. Close container after each use. Wash thoroughly after handling.
WARNING Cancer and Reproductive Harm– www.P65Warnings.ca.gov Refer to the product label & Safety Data Sheet for product specific information.
FIRST AID: If affected by inhalation of vapors or spray mist, remove to fresh air. In case of eye contact, flush immediately with plenty of water for at least 15 minutes and get medical attention immediately; for skin, wash thoroughly with soap and water. If symptoms persist, seek medical attention. If swallowed, do not induce vomiting. Get medical attention immediately.
IN CASE OF SPILL – Absorb with inert material and dispose of as specified under “Clean Up”.
Refer to Safety Data Sheet for additional health and safety information.
http://www.coronadopaint.com/
Manufactured by Benjamin Moore & Co.
This is the start of the file's text. The full file is on GovTribe.