This is an electric specification sheet for a Hobart CLPS66eN-BAS high-temperature rack conveyor dishwashing machine submitted by the Florida Department of Veterans' Affairs (FDVA) for the Emory L. Bennett State Veterans' Nursing Home kitchen equipment replacement project. The specification sheet provides detailed technical information for the commercial dishwasher that will replace an existing Champion dishwasher model 44 Pro at the facility located in Daytona Beach, Florida. The Hobart dishwasher features a capacity of 202 racks per hour, a 23-gallon wash tank, a 22-inch power scrapper, and NSF-approved pot and pan cycle mode with configurable intelligent de-lime notification and dirty water indicators. The machine accommodates up to six standard sheet pans simultaneously with a 19.5-inch chamber height and includes top-mounted computer controls, insulated ergonomic cabinet doors, and an Opti-Rinse system. The procurement involves disconnection and removal of the existing dishwasher, installation of the new Hobart unit with all plumbing and electrical connections, and disposal of the old equipment in accordance with manufacturer specifications and warranty requirements.

The specification sheet details comprehensive technical requirements including water consumption of 126 gallons per hour maximum at 20 PSI and 0.62 gallons per rack, with a peak drain flow of 38 gallons per minute. The machine requires 15 kilowatts of tank heat with optional internal electric booster heater options of 15 or 30 kilowatts. Electrical connections are available in multiple voltage configurations including 208/60/3, 240/60/3, 480/60/3, and 600/60/3, with rated amperage ranging from 22.6 to 144.5 amps depending on voltage and booster specifications. The unit has venting load requirements of 200 CFM at the load end and 400 CFM at the unload end. Optional accessories include stainless steel vent hoods in standard, short, and extended configurations, direct drive unloader, side loaders, blower-dryer, drain water tempering kit, and correctional packages. The machine weighs approximately 855 pounds and ships in crated dimensions of 76 inches length by 38 inches width by 78 inches height. Installation requires minimum incoming water temperature of 110 degrees Fahrenheit for booster operation, recommended water hardness of 3 grains or less, and water pressure of 20 PSI with a tolerance of plus or minus 5 PSI.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by______________________________________ Date___________ Approved by______________________________________ Date___________

CLPS66eN-BAS ELECTRIC High Temperature Rack Conveyor Dishwashing Machine

Printed in U.S.A. HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com F40636 (03/21) Page 1 of 4

CLeN SERIES – CLPS66eN-BAS ELECTRIC

COM

M

ERCIAL

DISHW

ASHERS

Project_____________________________________________________________________

AIA #_________________________________ SIS #_________________________________

Item #________________________________ Quantity_________ C.S.I. Section 114000

SPECIFIER STATEMENT

Specified dishwasher will be Hobart CLPS66eN Base electric tank heat model with Opti-Rinse™.

Includes 22" power scrapper, insulated ergonomic cabinet style doors, dirty water indicator, con-figurable “intelligent” de-lime notification, top mounted computer controls, and NSF approved pot and pan cycle mode. The wash tank utilizes durable precision pressure sensor monitors in lieu of conventional mechanical floats. The 19.5" standard chamber height will accommodate up to (6) standard sheet pans at a time on an open-end sheet pan rack.

STANDARD FEATURES

+ 202 racks per hour
+ 22" power scrapper
+ Opti-Rinse™ system
+ Rapid return conveyor drive mechanism
+ Large double door opening for ease of cleaning
+ Doors are insulated & hinged with door interlock switches
+ 19.5" chamber height opening (accepts sheet pans)
+ Top mounted micro-processor control module
+ Energy saver mode (programmable auto-shut down)
+ Dirty water indicator
+ Manager activated low temperature alert
+ NSF rated configurable pot and pan dwell mode
+ Configurable “intelligent” delime notification
+ Service diagnostics
+ Self-aligning wash manifolds
+ Stainless steel anti-clogging wash arms
+ Stainless steel self-draining pump and impeller
+ Single, sloping scrap screen and deep scrap basket
+ Stainless panels enclose perimeter and bottom
+ Door actuated drain closure
+ Convertible hot water or low temp final rinse
+ Vent fan control
+ Booster heater control
+ Power scrapper vent cowl curtain kit
+ ENERGY STAR® Certified

OPTIONS & ACCESSORIES (Available at extra cost)

❑ Standard, short, and extended stainless steel vent hoods
❑ Internal stainless steel pressure-less 30 kW booster heater

field convertible to 15 kW (booster includes PRV) + Dual point electrical connection standard on 208/60/3 and 240/60/3 voltage machines, when equipped with internal booster; single point kits available (see page 3)

+ Single point connection standard on 480/60/3 and 600/60/3 voltage machines, when equipped with internal booster

❑ Direct drive unloader – adds 38" length. Reference spec F39520 for more details

❑ Side loader – SL23 adds 23" length, SL30 adds 30" length.

Reference specs F40926 and F40927 for more details

❑ Blower-dryer – adds 331⁄4" to length. Reference spec F40252 for more details (ships separate from dishmachine, contact Hobart Service for installation)

❑ Drain water tempering kit (field installed)
❑ Flanged feet kit (requires two kits)
❑ Higher than standard chamber (24" opening)
❑ Table limit switch with 10' wire
❑ Correctional package (contact Hobart for details)
❑ Pressure regulator valve (PRV), for use with external booster
❑ Water shock absorber kit
❑ Factory-mounted circuit breakers (contact Hobart for details)
❑ Field installed single point kits available for 208/60/3 and

240/60/3 machines when equipped with internal booster

Page 2 of 4 CLPS66eN-BAS ELECTRIC

High Temperature Rack Conveyor

Dishwashing Machine

CAD and/or Revit Files Available

P3

V1

L-R OPER

7 3/8

65 1/2"10"

TYP

5"

68 1/2"

21 5/8"

V1

R-L OPER

68 1/2"

7 3/8

65 1/2"10"

TYP

5" 21 5/8"

20" SERVICE

CLEARANCE

(BOTH SIDES)

23"

OPEN DOOR

CLEARANCE

29 1/2"

62 1/2"

47 13/16" 55 1/2"

62 9/32" P2 E2 E1

P2 E1 E2

23"

OPEN DOOR

CLEARANCE

20" SERVICE

CLEARANCE

(BOTH SIDES)

32 3/4" 41 15/32"

62 13/64"

62 1/2"

22"

BOTH ENDS

19 11/16"

31 1/16"

7 3/8"

5" RECOMMENDED

MIN. DISTANCE

FROM WALL13"

WALL

WIDTH OF

TRACKS

WIDTH OF

MACHINE 20" 27"

11"

27"

AVG INSIDE

TABLE WIDTH

14 1/2"

CL

MACHINE 2 HOLES FOR BOLTING

TABLE TO TANK

FRONT OF

MACHINE

CL

3/8"

3/8"

3"

1 1/4"

8" AVG

22"

INSIDE TANK

3"

65 9/16" 65 9/16"

P3 P3 36 7/8"

P1P1

34"

E3 E3

E3E1 E2

63 3/4"

Top View Left to Right Top View Right to Left

Front View Left to Right Front View Right to Left

Side View

MODEL:

CLPS66eN BASE

L-R OPERATION

D-974807

REV B

MODEL:

CLPS66eN BASE

R-L OPERATION

D-974806

REV B

Suggested Track and Table Layout

View Showing Hole Locations in Turned Down Portion of Table

Tabling Connection: 66" inside tank (at table connection) http://hobart.kclcad.com/mobile

High Temperature Rack Conveyor

Dishwashing Machine

CLPS66eN-BAS ELECTRIC Page 3 of 4

SPECIFICATIONS

Capacities

Racks per Hour (NSF rated). . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Wash Tank (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power Scrapper (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Conveyor Speed (feet per minute). . . . . . . . . . . . . . . . . . . . . . . . 5.6

Motor Horsepower

Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6
Wash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Power Scrapper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Water Consumption

U.S. Gallons per Hour (maximum use at 20 PSI). . . . . . . . . . . . 126
U.S. Gallons per Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.62
Peak Drain Flow (U.S. gallons per minute). . . . . . . . . . . . . . . . . . 38

Heating

Tank Heat, Electric (kW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional Electric Booster (built-in) (kW for 40°F rise). . . . . . . . 15
Optional Electric Booster (built-in) (kW for 70°F rise). . . . . . . . 30

Venting

Load End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Unload End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . 400

Shipping Weight (approximate). . . . . . . . . . . . . . . . . . . . . . . 855 lbs.

Crated Dimensions. . . . . . . . . . . . . . . . . . . . . . . 76"L x 38"W x 78"H

LEGEND

Electrical Connections

Required when machine equipped with

SINGLE POINT ELECTRICAL CONNECTION

E1 Tank heat, motors, controls AND 30kW booster heater – multiple knockouts provided, 63-3/4" AFF.

Required when machine equipped with

DUAL POINT ELECTRICAL CONNECTION

E2 Tank heat, motors and controls – multiple knockouts provided, 63-3/4" AFF.

E3 Internal 30kW booster heater – multiple knockouts provided, 63-3/4" AFF.

Multiple knockouts provided for 2", 1" and 1/2" trade size conduits.

Plumbing Connections

P1

Drain. May be drained to either side of valve, plug opposite side 2" FPT. Recommend a floor drain minimum of 12'' from machine for access and maintenance. 7-3/8" AFF.

P2 Hot water. 1/2" FPT connection. 1/2", 11-3/16" AFF.

See plumbing notes for required temperatures.

P3 Optional cold water connection for drain water tempering 1/2" FPT, cold water temperature 80°F, maximum 7-3/8" AFF.

Vent Connections

V1 Optional vent hoods, 4" x 16" vent stack with damper.

E1 Single Point Electrical Connection with internal 30 kW Booster Heater

Voltage

(E1) Tank Heat, Motors, Controls 30kW Booster Heater

Single Point Service Connection Rated Amps

Minimum Supply Circuit Ampacity / Maximum Protective Device

208/60/3 144.5 175 Field Installed SGLPT-KIT4-CLE required, order separately 240/60/3 138.2 150 Field Installed SGLPT-KIT2-CLE required, order separately 480/60/3 70.7 90 Ships Standard, Factory Installed 600/60/3 49.4 60 Ships Standard, Factory Installed

E2 Dual Point Electrical Connection with Internal 30 kW Booster Heater (For machines without internal booster heater, refer to E2, Tank Heat, Motors & Controls connection only)E3

Voltage

(E2) Tank Heat, Motors, Controls (E3) 30kW Booster Heater

Dual Point Service ConnectionRated Amps

Minimum Supply Circuit Ampacity / Maximum

Protective Device Rated Amps

Minimum Supply Circuit Ampacity / Maximum

Protective Device 208/60/3 60.6 80 83.9 90 Dual Point Ships Standard 240/60/3 58.0 80 80.2 90 Dual Point Ships Standard 480/60/3 30.6 40 40.1 50 Field Convertible 600/60/3 22.6 35 26.9 40 Field Convertible

High Temperature Rack Conveyor

Dishwashing Machine

As continued product improvement is a policy of Hobart, specifications are subject to change without notice.

F40636 (03/21) Page 4 of 4 HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.

VENT HOOD OPTIONS (Adjustable, vent stack can be adjusted 1" to either side)

Standard Short Extended

4 3/4"

OUTSIDE

11 1/4"

OUTSIDE

REF

10" 10"

4 3/4"

OUTSIDE

5 3/4"

OUTSIDE

REF

10"

4 3/4"

OUTSIDE

20 1/2"

OUTSIDE

REF

CLPS66eN-BAS Electric Heat Dissipation

Booster

BTU/HR.

Latent Sensible Without Booster 15,800 6,800

15kW Booster 29,300 12,600 30kW Booster 42,900 18,400

NOTE: 30kW Booster Heater field convertible to 15kW when 140°F incoming water provided.

(Conversion instructions located in machine control box. Contact factory for 15kW booster amperage ratings.)

NOTE: Additional CLeN Voltages and Amperages are available, see document F40972.

WARNING: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and National Electrical Code.

Plumbing Notes: Minimum incoming water temperatures: 110°F for 30kW internal booster, 140°F for 15kW field converted internal booster, 180°F without internal booster. Building flowing water pressure to dish machine is 20 PSI, (+/- 5 PSI). For non-booster machines, a PRV with internal expansion bypass is required.

When ordered as an accessory, 1⁄2" brass regulator must be installed before the booster. Water temperature to the regulator must not exceed 140°F.

Recommended water hardness to be 3 grains or less for best results.

Electrical Note: Dishmachine not provided with internal GFCI protection.