This combined synopsis/solicitation from the Department of the Army Materiel Command seeks proposals for the procurement of Accelerated Vehicle Durability Simulator Cooling Towers. The solicitation requires the delivery and installation of four cooling towers for Building 385 within four to six months of award and one cooling tower for Building 384F within six to seven months of award. The period of performance is from May 15, 2021 to March 15, 2022. Offerors must provide firm fixed pricing for the delivery and installation of the cooling towers. The contract will be awarded to the lowest price technically acceptable offeror following a technical evaluation of proposals submitted by April 1, 2021. The solicitation seeks all labor, equipment, materials, and supervision to install the cooling towers according to the performance work statement and drawings provided as attachments.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(3) ESWB 12-45N18
Project Details
Project Name : APG Bldg 385 Location: TBD
Date: 8/13/2019 Customer:
Contact:
Contact Email:
Product Description The ESWB utilizes fill media in conjunction with a closed loop coil providing sensible and latent heat transfer. The ESWB provides superior evaporative cooling performance as a result of its hybrid technology and its full footprint patented Sensi-Coil®, featuring CrossCool™ Internal Tube Enhancement. This results in the most efficient closed circuit coolers in the industry with the lowest connected fan horsepower and smallest footprint. With the coil located out of the air stream, only sensible cooling is utilized, resulting in no evaporation on the coil which reduces scale buildup!
Selection Criteria Total Each Unit
Flow: 2,400.0 GPM 800.0 GPM
Fluid:
30%
Propylene Glycol
30% Propylene
Glycol Entering Fluid Temp: 105.0 F 105.0 F Leaving Fluid Temp: 85.0 F 85.0 F Entering Wet Bulb: 78.0 F 78.0 F
Required Capacity
22,838.47 MBH
1,522.56 Tons
Unit Selected Three(3) EVAPCO ESWB 12-45N18 at 103.4% capacity (7,874.01 MBH each) Product line is CTI/ECC certified for water, propylene glycol or ethylene glycol as process fluid. Selection is rated in accordance with CTI Standard 201 RS.
Physical Data Per Unit Overall Dimensions (WxLxH): 11'-10" x 18'-0" x 22'-2 1/4" Operating Weight: 59,200 lbs Shipping Weight: 38,830 lbs Heaviest Section: 29,140 lbs *weights and dimensions could vary depending on options selected
IBC Design Capability IBC Standard Structural Design
1.0 Importance Factor Specified
Seismic(Sᴅs): up to 1.6 g, z/h = 0 Wind Load(P): up to 119 psf
Fan Motor Data per Unit Number of Fans: 1 # of Fan Motors: 1 Nameplate Power (460/3/60): 40.00 HP Per Motor
Pump Motor Data per Unit No.of Pumps: 2 Nameplate Power (460/3/60): 7.5 HP per pump motor Total Connected Nameplate Power: 15 HP
Additional Details Per Unit Air Flow: 145,200 CFM Riser Pipe Diameter: 6"
Hydraulic Data Pressure Drop Through Coil: 6.5 psi Evaporated Water Rate: 12.18 GPM Spray Water Flow: 1,700 GPM
Layout Criteria From FACE B/D to wall: 3.00ft From FACE A/C to wall: 3.00ft Between FACE B/D ends: 3.00ft Between FACE A/C sides: 6.00ft
Sound Data(dB(A) @ 5'/50') Face A (Opp Mtr. Side): 77/63 Face C (Motor Side): 77/63 Face B (End): 77/61 Face D (Opp End): 77/61 Top: 73/62 Notes: Sound Pressure Levels are according to CTI Standard ATC-128 and verified by an independent CTI-licensed sound test agency. Sound data is shown for 1 cell operating at full speed. The use of frequency inverters (Variable Frequency Drives) can increase sound levels. Sound Options: Super Low Sound Fan
Shipping Data 1 Basin Sections: (WxLxH): 142" x 256" x 133" ; 29140lbs each* | 1 Casing Sections: (WxLxH): 142" x 256" x 128" ; 9690lbs each* *dimensions and weights above include shipping skids
Accessories
(1) Fan Motor: Inverter Capable, Premium (1) Fan Motor: Space Heaters (1) IBC Standard Structural Design
Closed Circuit Cooler Technical Data Sheet Chris Delp 425 McFarlan Road Suite 209 Kennett Square, Pennsylvania 19348
610-554-8863 chrisd@etshvac.com
Spectrum Version: 2.2019.801.1 August 13, 2019Page 1 of 14
Efficient
(1) Louver Access Door (1) 1.0 Importance Factor Specified (1) CrossCool Coil
(1) 5-Probe Electronic Water Level Control Package (1) El. Heaters (0F / -18C ambient) (2) 9 kW (1) Sump Sweeper Piping (High Flow Eductors)
(1) Vibration Switch (1) 304 Welded Stainless Steel Cold Water Basin (1) External Service Platform with Ladder
(1) Safety Cage (1) Super Low Sound Fan (3) Smart Shield Package ((2)FMF-10-6,(1)BCF-20)
(1) Smart Shield Startup and Service; 12 Months;
4.00 COC; 18 Boxes of biocide; 23 Box ET; IIL 19;
IOL 29
(3) Ethernet (3) Corrosion Coupon Rack
Spectrum Version: 2.2019.801.1 August 13, 2019Page 2 of 14
REV.
NO. OF SHIPPING SECTIONSHEAVIEST SECTION
WEIGHT
UNIT
SCALE
DWG. #
SERIAL #MODEL #
SHIPPING
WEIGHT
DATE
DRAWN BY:OPERATING
WEIGHT
2'-1 1/2" 648 3 5/8"
4 1/4"
11'-10"
18'-0"
2'-3"
7"
(2) 1/2" [15] FPT
VENT
ACCESS
DOOR
2" [50] MPT
MAKE-UP
3" [80] MPT
DRAIN
2'-6 3/4"
NOTES:
1. (M)- FAN MOTOR LOCATION
2. HEAVIEST SECTION IS COIL SECTION
3. MPT DENOTES MALE PIPE THREAD
FPT DENOTES FEMALE PIPE THREAD
BFW DENOTES BEVELED FOR WELDING
GVD DENOTES GROOVED
FLG DENOTES FLANGE
4. +UNIT WEIGHT DOES NOT INCLUDE
ACCESSORIES (SEE ACCESSORY
DRAWINGS)
5. 3/4" [19MM] DIA. MOUNTING HOLES.
REFER TO RECOMMENDED STEEL
SUPPORT DRAWING
6. MAKE-UP WATER PRESSURE
20 psi [137 kPa] MIN, 50 psi [344 kPa] MAX
7. DIMENSIONS LISTED AS FOLLOWS:
ENGLISH FT-IN
[METRIC] [mm]
8. * - APPROXIMATE DIMENSIONS DO
NOT USE FOR PRE-FABRICATION
OF CONNECTING PIPING.
18'-0"
8 1/4"
5'-6 3/4" 1695 *
2'-10 1/2" 876 *
2'-7 3/8" 797 *
(2) 4" [100] BFW
FLUID IN
(2) 4" [100] BFW
FLUID OUT
3" [80] MPT
OVERFLOW
3'-1 5/8" 956 *
4'-9 7/8"
1'-1"
11'-10"
2'-3"
10'-6 3/4"
11'-7 1/2"
22'-2 1/4"
NTS
WXB12184810-DRB-SLF
SLR
FACE A
FACE B
FACE A
FACE B
FACE C
FACE D
PLAN VIEW
EVAPCO, INC.CLOSED CIRCUIT COOLER
ESWB 12-45N18
8/13/2019
38830 lbs+ [17615] kg+ 59200 lbs+ [26855] kg+ 29140 lbs+ [13220] kg+ 2
Spectrum Version: 2.2019.801.1 August 13, 2019
Preliminary
TITLE
UNIT
SCALE
DWG. #
DRAWN BYSTEEL SUPPORT CONFIGURATION
SLWXB1218-DC
TYPICAL END VIEW
UNIT
MOUNTING HOLE
13/16"
1 5/8"
(12) 3/4" O [19mm]
MOUNTING HOLES
PLAN VIEW
C/L OF UNIT LOAD
UNIT OUTLINE
11'-10"
18'-0"
1 15/16"
4 15/16"
1 15/16"
4 15/16"
13/16"
11'-8 3/8"
C/L OF MOUNTING HOLES
13/16"
N.T.S. SLR
7 5/8"
7'-10 7/8"
7 5/8"
7'-10 7/8"
NOTES:
1. BEAMS SHOULD BE SIZED IN ACCORDANCE WITH ACCEPTED STRUCTURAL PRACTICES.
MAXIMUM DEFLECTION OF BEAM UNDER UNIT TO BE 1/360 OF UNIT LENGTH NOT TO
EXCEED 1/2" [13mm].
2. DEFLECTION MAY BE CALCULATED BY USING 55% OF THE OPERATING WEIGHT AS
A UNIFORM LOAD ON EACH BEAM. SEE CERTIFIED PRINT FOR OPERATING WEIGHT.
3. SUPPORT BEAMS AND ANCHOR HARDWARE ARE TO BE FURNISHED BY OTHERS.
ANCHOR HARDWARE TO BE ASTM A325 5/8" [16mm] BOLT OR EQUIVALENT.
4. BEAMS MUST BE LOCATED UNDER THE FULL LENGTH OF THE PAN SECTION.
5. SUPPORTING BEAM SURFACE MUST BE LEVEL. DO NOT LEVEL THE UNIT BY
PLACING SHIMS BETWEEN THE UNIT MOUNTING FLANGE AND THE SUPPORTING BEAM.
6. THE FACTORY RECOMMENDED STEEL SUPPORT CONFIGURATION IS SHOWN.
CONSULT THE FACTORY FOR ALTERNATE SUPPORT CONFIGURATIONS.
7. UNIT SHOULD BE POSITIONED ON STEEL SUCH THAT THE ANCHORING HARDWARE FULLY
PENETRATES THE BEAM'S FLANGE AND CLEARS THE BEAM'S WEB.
8. WHEN VIBRATION ISOLATION IS REQUIRED, THE VIBRATION ISOLATORS (BY OTHERS)
MUST BE LOCATED UNDER THE SUPPORTING BEAMS AND NOT BETWEEN THE SUPPORTING
STEEL BEAMS AND THE UNIT.
9. DIMENSIONS LISTED AS FOLLOWS: ENGLISH FT-IN
[METRIC] [mm]
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
FAN MOTOR SPACE HEATERS
MHAU0000-DB
N.T.S. BLL
MOTOR
FAN
NOTE:
1. FAN MOTOR SPACE HEATERS SHOULD BE ENERGIZED WHEN MOTOR IS OFF TO PREVENT CONDENSATION IN THE MOTOR
2. FAN MOTOR SPACE HEATERS MUST BE SWITCHED OFF WHEN MOTOR IS RUNNING
L1/H1 L2/H2
HEATER 1
HEATER 2
ELECTRICAL DATA:
VOLTAGE: 120V
CURRENT: <2AMPS
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
NOTES:
1. LADDER AND PLATFORM SHIP LOOSE. FIELD INSTALLATION BY OTHERS IS REQUIRED.
2. THE BOTTOM OF THE LADDER DOES NOT EXTEND PAST THE BASE OF THE UNIT.
IF THE UNIT IS ELEVATED THEN AN OPTIONAL EXTENDED LADDER PACKAGE
SHOULD BE CONSIDERED. (CONSULT FACTORY)
3. REFER TO RIGGING PACK FOR LADDER AND PLATFORM MOUNTING INSTRUCTIONS.
4. EACH PLATFORM AND LADDER ASSY. WEIGHS 670 LBS. [304 KG]
5. DIMENSIONS LISTED AS FOLLOWS: ENGLISH FT-IN
[METRIC] [mm]
EXTERNAL SERVICE PLATFORM
PLWXB1218-DA
3'-3 5/8"
H
2'-4 3/8" 721 7'-3"
3'-2"
5'-4 7/8"
9 3/8"
FACE C
FACE D
N.T.S. BLL
FT-IN [mm]
ESWB 12-23J18, 23J18X, 23K18, 23K18X, 23L18, 23L18X,
23M18, 23M18X, 23N18, 23N18X, 23O18, 23O18X
ESWB 12-24J18, 24J18X, 24K18, 24K18X, 24L18, 24L18X,
24M18, 24M18X, 24N18, 24N18X, 24O18, 24O18X
ESWB 12-25J18, 25J18X, 25K18, 25K18X, 25L18, 25L18X,
25M18, 25M18X, 25N18, 25N18X, 25O18, 25O18X
ESWB 12-26J18, 26J18X, 26K18, 26K18X, 26L18, 26L18X,
26M18, 26M18X, 26N18, 26N18X, 26O18, 26O18X
ESWB 12-33J18, 33J18X, 33K18, 33K18X, 33L18, 33L18X,
33M18, 33M18X, 33N18, 33N18X, 33O18, 33O18X
ESWB 12-34J18, 34J18X, 34K18, 34K18X, 34L18, 34L18X,
34M18, 34M18X, 34N18, 34N18X, 34O18, 34O18X
ESWB 12-35J18, 35J18X, 35K18, 35K18X, 35L18, 35L18X,
35M18, 35M18X, 35N18, 35N18X, 35O18, 35O18X
ESWB 12-36J18, 36J18X, 36K18, 36K18X, 36L18, 36L18X,
36M18, 36M18X, 36N18, 36N18X, 36O18, 36O18X
ESWB 12-43J18, 43J18X, 43K18, 43K18X, 43L18, 43L18X,
43M18, 43M18X, 43N18, 43N18X, 43O18, 43O18X 43P18, 43P18X
ESWB 12-44J18, 44J18X, 44K18, 44K18X, 44L18, 44L18X,
44M18, 44M18X, 44N18, 44N18X, 44O18, 44O18X 44P18, 44P18X
ESWB 12-45J18, 45J18X, 45K18, 45K18X, 45L18, 45L18X,
45M18, 45M18X, 45N18, 45N18X, 45O18, 45O18X 45P18, 45P18X
ESWB 12-46J18, 46J18X, 46K18, 46K18X, 46L18, 46L18X,
46M18, 46M18X, 46N18, 46N18X, 46O18, 46O18X 46P18, 46P18X
H DIM
MODEL #
14'-3 5/8 "
13'-8 1/8 "
14'-6 5/8 "
12'-8 1/8 "
13'-11 1/8 "
13'-3 5/8 "
16'-6 5/8 "
15'-6 5/8 "
14'-11 1/8 "
14'-8 1/8 "
15'-3 5/8 "
15'-11 1/8 "
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
ELECTRIC WATER LEVEL CONTROL LOCATION
ELWXBMWML-DE
NOTES:
1. PIPING BY OTHERS.
2. LEVEL PROBE STANDPIPE ASSEMBLY, MAKE-UP VALVE AND Y-STRAINER TO SHIP LOOSE FOR FIELD MOUNTING BY OTHERS.
3. SEE CERTIFIED PRINT FOR MAKE-UP LOCATION.
4. STANDPIPE TO BE HEAT TRACED AND INSULATED FOR WINTER OPERATION (BY OTHERS).
5. THE ELECTRONIC WATER LEVEL CONTROL ON THIS UNIT WILL MAINTAIN THE PROPER OPERATING WATER LEVEL.
HOWEVER, BEFORE INITIAL START-UP THE UNIT MUST BE MANUALLY FILLED TO WITHIN 1" OF THE OVERFLOW.
6. FOR EASE OF MAINTENANCE, A SHUT-OFF VALVE IS RECOMMENDED UPSTREAM OF Y-STRAINER.
7. DIMENSIONS LISTED AS FOLLOWS: ENGLISH FT-IN
[METRIC] [mm]
ELECTRIC MAKE-UP
VALVE WITH Y-STRAINER
UPSTREAM OF VALVE
(SEE CHART FOR SIZE & QTY)
CONN. END
LEVEL PROBE
STANDPIPE ASSEMBLY
(SEE CHART QTY)
X
Y
FACE C
JLGN.T.S.
QTY SIZE PART NO. QTY SIZE PART NO. QTY X Y
2.4Mx9/12 1 1" [25]
017-00153P 1 1" [25]
017-00280P 1 1'-2" [355]
8 1/2" [216]
2.4Mx18 1 1 1/2" [40]
017-00154P 1 1 1/2" [40]
017-00281P 1 1'-2" [355]
8 1/2" [216]
8.5x6/9/12 1 1" [25]
017-00153P 1 1" [25]
017-00280P 1 1'-2" [355]
8 1/2" [216]
8.5x18 1 1 1/2" [40]
017-00154P 1 1 1/2" [40]
017-00281P 1 1'-2" [355]
8 1/2" [216]
12x12 1 1 1/2" [40]
017-00154P 1 1 1/2" [40]
017-00281P 1 1'-2" [355]
9 1/2" [241]
12x18 1 2" [50]
017-00155P 1 2" [50]
017-00282P 1 1'-2" [355]
9 1/2" [241]
UNIT
SELECTED BOX SIZE
VALVE Y-STRAINER STANDPIPE
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY HEATER LOCATION
HLWXB12VE-DB
LWCO
017-00207PA
BULB WELL
017-00006P
LWCO COVER PLATE
(INSIDE UNIT)
THERMOSTAT
017-00005P
HEATER CONTROL PANEL
(SEE WIRING DIAGRAM)
(2) IMMERSION
HEATERS
(ONE EACH END)
6"
1'-0"
3'-3"
6'-7"
7'-9"
11"
FACE D
N.T.S. JLG
NOTES:
OUTLET BOX AND THE NEAREST OBSTRUCTION FOR REMOVAL OF THE HEATER.
ALL NIPPLES ON UNIT ARE NOT SHOWN IN ORDER TO CLARIFY
ALL HEATER COMPONENTS BY EVAPCO ARE FACTORY MOUNTED WHEN POSSIBLE.
DIMENSIONS LISTED AS FOLLOWS: ENGLISH FT-IN
HEATER COMPONENT LOCATIONS.
A MINIMUM OF CLEARANCE IS REQUIRED BETWEEN THE HEATER
2.
4.
3.
1.
[METRIC] [mm]
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BYN.T.S.SMART SHIELD ENGINEERING DATA
SS3AU0000-DC
MBG
FMF
H
W
BCF-10 BCF-20
H
W D
H
W D
D
D W H
FMF-6-3 1'-7" [480] 1'-1" [330] 3'-7" [1090] 44 [20] 111 [50] 3/4 [20]
FMF-6-4 1'-7" [480] 1'-2" [360] 3'-7" [1090] 49 [22] 116 [53] 3/4 [20]
FMF-10-6 1'-7" [480] 1'-4" [405] 4'-1" [1240] 75 [34] 165 [75] 3/4 [20]
FMF-10-8 1'-7" [480] 1'-6" [460] 4'-3" [1290] 95 [43] 185 [84] 1 [25]
BCF-10 1'-5" [430] 9" [230] 1' [305] 30 [14] 34 [15] NA
BCF-20 1'-5" [430] 2'-1" [630] 1' [305] 60 [27] 69 [31] NA
Smart Shield Component
Dimensions ft-in [mm]
FMF
Shipping Weight lb [kg]
Operating Weight lb [kg]
Blow Down Valve Size in [mm]
BCF
NOTES:
1. UNITS ARE DESIGNED FOR A MAXIMUM WATER TEMPERATURE OF 130°F [50°C]
2. THE FMF AND BCF MUST HAVE UNOBSTRUCTED RETURN PIPING TO BASIN.
3. DIMENSIONS ARE APPROXIMATE. DO NOT USE FOR PRE-FABRICATION OF PIPING.
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BYN.T.S.SMART SHIELD/
CONDUCTIVITY WIRING DIAGRAM
SS1AU0000-DE
CAF
120/230 VOLT PANEL FACTORY WIRED
NOTES:
1. DASHED LINES INDICATE WIRING BY OTHERS.
2. INSTALLATION SHOULD COMPLY WITH NATIONAL, STATE, AND LOCAL CODES.
3. WIRE SECONDARY CONTACT FROM PUMP STARTER TO DIGITAL INPUT IN ORDER TO RECORD PUMP OPERATIONAL HOURS.
4. UNITS ARE STANDARD WITH NEMA 4X (EQUIVALENT TO IP65) ENCLOSURE. CE AND ETL LISTED, MEETING UL AND cUL SPECIFICATIONS.
4-20 mA
ANALOG
OUTPUT #2
(OPTIONAL)
SHIELD
TB2
4-20 mA
ANALOG
OUTPUT #1
(OPTIONAL)
SHIELD
H20 METER #2
(OPTIONAL)
POLARITY NOT CRITICAL
NEUTRAL
GROUND 6
W
HT
V
BL
U
0V
TB5
FLOW SW
POLARITY NOT CRITICAL
TB3
GR
N
0V
GR
N/
YE
L
0V
BLK 120V
BRN 240V
WHT 120V
BLU 240V
TB4
POWER
SUPPLY
N L
TB7
NC
NO
BLOWDOWN VALVE
R1
XMT + WHT
XMT - BLK
RCV - BLK
RCV + RED
X-SHLD (SHIELD)
TEMP - BLK
TEMP + GRN
R-SHLD (SHIELD)
CONDUCTIVITY
PROBE
TB1
H20 METER #1
(OPTIONAL)
POLARITY NOT CRITICAL
PANEL VIEW
RIBBON
CABLE
ETHERNET
(OPTIONAL)
4-20 mA
ANALOG
OUTPUT #1
(OPTIONAL)
CONDUCTIVITY
SENSOR CARD
LOCAL
AREA
NETWORK
(LAN)
RJ45 CONNECTOR
CA
T5
CA
BL
E
NC
NOR2
NC
NOR3
NC
NOR4
BL
K
V
BR
N
0V
DOOR VIEW
EVAPCO CONDUCTIVITY CONTROLLER 2
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
NOTES:
SSWXB1200-DRC-ST
FACE AFACE B
PSJN.T.S.
1. BIO CONTROL FEEDER(S) MAY EXTEND THE OVERALL LENGTH OF THE UNIT
BY UP TO 8" [205mm].
2. COIL CONNECTIONS NOT SHOWN FOR CLARITY.
3. REFER TO SMART SHIELD IOM FOR PROPER DRAIN CONNECTION.
4. ALL PVC RETURN CONNECTIONS INTO UNIT REQUIRE FIELD HAND TIGHTENING.
5. ALL PVC UNIONS REQUIRE FIELD HAND TIGHTENING.
6. PROVIDE 30" OF ACCESS IN FRONT OF SMART SHIELD FEEDERS AND CONTROL
EQUIPMENT FOR MAINTENANCE AND PRODUCT REPLENISHMENT.
(2) BIO CONTROL
FEEDER (BCF)
BLOWDOWN VALVE
W/ WEATHER SHIELD
CONDUCTIVITY
PROBE
EVAPCO
CONDUCTIVITY
CONTROLLER
FACTORY MOUNTED
FEEDER (FMF)
(2) FACTORY MOUNTED
FEEDER (FMF)
(ONE EACH END)
(12X18 ONLY)
FIELD CONNECTION REQUIRED
FIELD CONNECTION TO
DRAIN REQUIRED
ISOLATION VALVE SHIPS LOOSE. OVERFLOW AND BLOWDOWN CONNECTION.
SEE NOTE 3.
SEE NOTE 1
FACTORY MOUNTED
FEEDER (FMF)
(12x18 ONLY)
FACE D
SMART SHIELD ARRANGEMENT
SEE NOTE 6
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
B2AU0000-DB
N.T.S.3Ø HEATER WIRING DIAGRAM 2 HEATERS SLR
NOTES:
1. DASHED LINES INDICATE FIELD WIRING.
2. THE HEATERS HAVE BEEN SIZED TO MAINTAIN
PAN WATER AT AN AMBIENT TEMPERATURE OF
3. ALL COMPONENTS BY EVPACO HAVE TYPE 4 ENCLOSURES.
4. AUXILIARY N.C. CONTACT INTERLOCKS IMMERSION HEATERS WITH
SPRAY WATER CIRCULATING PUMP TO DE-ENERGIZE HEATERS WHEN
SPRAY PUMP IS RUNNING.
5. (1) CONTACTOR IS SUPPLIED FOR EVERY (2) HEATERS
- CONTACTOR SHOULD BE WIRED WITH SEPARATE SUPPLY
TERMINALS FOR EACH HEATER.
6. (1) CONTACTOR IS SUPPLIED PER CELL OF A MULTICELL UNIT
- PROVIDES FOR INDIVIDUAL CELL OPERATION.
IMMERSION HEATER BY:
LOW WATER CUTOFF/THERMOSTAT CONTROL BY:
AUXILIARY N.C. PUMP INTERLOCK BY:
HEATER CONTROL PANEL BY:
TRANSFORMER BY:
HEATER CONTACTOR BY:
FUSED DISCONNECT BY:
EVAPCO
EVAPCO
OTHERS
L1 L2
L1 L2
(H4) (H1)
(X2)(X1)
(H2) (H3)
120V
- REMOTE DEVICE
- TERMINAL POINT
RECOMMENDED POWER AND CONTROL WIRING
- ALL HEATERS AND CONTROLS NOT PROVIDED BY EVAPCO
TO BE INSTALLED AND WIRED BY OTHERS
- ALL POWER WIRING BY OTHERS
- ALL FIELD WIRING BY OTHERS
CON 1
J
LT1
G
BLUE RED
CR1 8
CR1
UNIT 1
HEATER
OFF AUTO
IF PUMP INTERLOCK
USED, REMOVE JUMPER
LOW WATER CUTOFF
THERMOSTAT
LINE VOLTAGE:
LINE VOLTAGE:
L3
CON 1
1H2
1H1
DISC
(2)
IMMERSION
HEATER
L3
1H3
1L2
1L1
1L3
EVAPCO, INC.ESWB 12-45N18
OTHERS
OTHERS
OTHERS
OTHERS
0° F 40° F
460/3/60
460/3/60
Spectrum Version: 2.2019.801.1 August 13, 2019
8/13/2019ESWB 12-45N18
TITLE DESCRIPTION:
EVAPCO, INC.
DWG. #VIBRATION SWITCH
ADJUSTMENT
ADJUST THE SWITCH SO THAT DURING FULL SPEED START-UP AND UNDER NORMAL CONDITIONS, THE CONTACTS DO NOT TRIP.
FIRST, WITH THE MOTOR OFF, TURN THE ADJUSTMENT SCREW COUNTER-CLOCKWISE (MORE SENSITIVE DIRECTION) UNTIL THE SWITCH TRIPS. NEXT, TURN THE ADJUSTMENT SCREW CLOCKWISE 1/8 TURN (LESS SENSITIVE DIRECTION). RESET THE SWITCH BY DEPRESSING THE PUSH-BUTTON RESET LOCATED ON TOP OF THE SWITCH. START THE MOTOR ON FULL SPEED. IF THE MOTOR TRIPS THE SWITCH, THEN TURN THE ADJUSTMENT SCREW CLOCKWISE AN ADDITIONAL 1/8 TURN. RESET THE SWITCH AND START THE
MOTOR AGAIN. REPEAT THE ABOVE PROCEDURE UNTIL THE MOTOR CONTINUES TO RUN.
SINGLE SPEED V1AU0000-EE
WIRING DIAGRAM:
DPDT
F
FAN
MOTOR
F
SUPPLIED VOLTAGE, 3 PHASE
INCOMING POWER
CIRCUIT
BREAKER
M1 OL1 1T1
1T2
1T3
SUPPLIED VOLTAGE
H1 H3 H2 H4
X1 X2
X2
OL1
M1
OPTIONAL
THERMOSTAT EVAPCO
SWITCH
HAND
OFF
DOX
AUTO
XDO
OFF
VIBRATION
017-00464P
MOTOR
(BY OTHERS)
CONTROL TRANSFORMER
CONTROL VOLTAGE
250 Vac; 1/2 AMP, 125 Vdc; 1/4 AMP, 250 Vdc.
15 AMPS, 125, OR 480 Vac; 1/8 HP, 125 Vac; 1/4 HP,
1. DASHED LINES INDICATE WIRING(BY OTHERS)
NOTES:
SWITCH CONTACT RATING:
F
F
F
F
Spectrum Version: 2.2019.801.1 August 13, 2019
SCALE
DWG. #
DRAWN BY
ELECTRIC WATER LEVEL CONTROL WIRING
D1AU0000-A
NOTES:
1. DASHED LINES INDICATE WIRING BY OTHERS.
2. TYPICAL WIRING PER PROBE.
120 VAC/60 Hz INTEGRAL LEVEL
PROBE/RELAY
IN A NEMA 4
POLYCARBONATE
ENCLOSURE
ELECTRIC MAKE-UP VALVE
(NORMALLY CLOSED)
120v POWER REQUIRED TO OPEN
L1 L2 NC C NO NC C NO NC C NO
L L
ALARM CIRCUIT
VOLTAGE
(AS DESIRED)
LOW ALARM HIGH ALARM
MWRN.T.S.
5 PROBE
EVAPCO, INC.ESWB 12-45N18
Spectrum Version: 2.2019.801.1 August 13, 2019