This is a combined synopsis and solicitation for commercial items seeking offers for the procurement of accelerated vehicle durability simulator cooling towers. Offers are requested to provide all labor, materials, equipment, and services necessary for delivery, installation, and integration of cooling tower systems for buildings 384F and 385 at Aberdeen Test Center by specified dates. Offerors shall submit firm fixed prices for CLIN 0001 to deliver and initially place the B385 cooling tower by four months after award and complete installation by six months after award. For CLIN 0002, prices shall be provided to deliver and initially place the B384F cooling tower by six months after award and complete installation by seven months after award. The period of performance is from May 15, 2021 to March 15, 2022. The solicitation will result in a fixed price award to the lowest priced technically acceptable offeror in accordance with simplified acquisition procedures. Responses are due by April 1, 2021 to the identified contracting officer and contract specialist at the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
1 2 4 5 6 73.4
C
D
1.1
A
VEHICLE TESTING
RESTROOM
RESTROOM
B
1 2 4 5 6 73.4 7.31.1
A
RESTROOM
RESTROOM
B
1 2 43.41.1
A
RESTROOM
RESTROOM
DATE:
SCALE:
CHECKED BY:
DRAWING NO:
FWA JOB NUMBER
AS NOTED
D E
S
IG
N P
H A
S E
I
FO
R
DRAWN BY:
A B
E R
D E
E N
T E
S T
C E
N
TE
R
A B
E R
D E
E N
P R
O V
IN
G
G R
O U
N D
BS/AL
10/02/20
AA/MF 2181128.00
95% SUBMISSION
A V
D T
FA
C
IL
IT
Y
FOR OFFICIAL USE ONLY
WARNING: Distribution authorized to U.S. Government agencies and their U.S. contractors.
REASON: Administrative/Operational Use; 7 January 2008. Other requests for this document shall be referred to Commander, USAATC, ATTN: TEDT-AT-CSI, APG, MD 21005-5059.
DESTRUCTION NOTICE-Destroy by any method that will prevent disclosure of contents or reconstruction of the document.
R
EV
IS
IO
N S
R
EV
D
A
TE
D
ES
C R
IP
TI
O
NLLC
DEDC #: 18P364
Delaware:
315 South Chapel Street
Newark, Delaware 19711 Phone: (302) 738-7172
Pennsylvania:
30 South 17th Street, United Plaza, Suite 830 Philadelphia, PA 19103 Phone: (267) 804-7286
SHEET
OF 87
P
LU
M B
IN
G
F
LO
O R
P
LA
N S
P100
AutoCAD SHX Text
FD
AutoCAD SHX Text
AutoCAD SHX Text
6"SANITARY DRAIN. REFER TO CIVIL DRAWINGS FOR CONTINUATION
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
LAV
AutoCAD SHX Text
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
WC
AutoCAD SHX Text
AutoCAD SHX Text
4"SAN
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
FD
AutoCAD SHX Text
AutoCAD SHX Text
FCO
AutoCAD SHX Text
AutoCAD SHX Text
FCO
AutoCAD SHX Text
AutoCAD SHX Text
BCO
AutoCAD SHX Text
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
2"SAN
AutoCAD SHX Text
4"SAN (TYP.-2)
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
2"SAN
AutoCAD SHX Text
6" SAN FROM CCC'S AREA. SEE M102 FOR CONTINUATION.
AutoCAD SHX Text
BCO
AutoCAD SHX Text
AutoCAD SHX Text
COORDINATE LOCATION WITH BFP. (TYP.-2)
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
FD
AutoCAD SHX Text
AutoCAD SHX Text
FD
AutoCAD SHX Text
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
3"SAN
AutoCAD SHX Text
2"SAN
AutoCAD SHX Text
3"SAN
AutoCAD SHX Text
HS
AutoCAD SHX Text
AutoCAD SHX Text
SH
AutoCAD SHX Text
AutoCAD SHX Text
2"SAN
AutoCAD SHX Text
3"SAN
AutoCAD SHX Text
UR
AutoCAD SHX Text
AutoCAD SHX Text
EW
AutoCAD SHX Text
AutoCAD SHX Text
BCO
AutoCAD SHX Text
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
6"SAN
AutoCAD SHX Text
LAV
AutoCAD SHX Text
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
WC
AutoCAD SHX Text
AutoCAD SHX Text
4"DCW. REFER TO CIVIL DRAWINGS FOR CONTINUATION
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
BFP
AutoCAD SHX Text
AutoCAD SHX Text
NOT SHOWN. LOCATED UNDER BFP-1. REFER TO 7/P300. ROUTE AIR GAP DRAIN TO FD.
AutoCAD SHX Text
HWH
AutoCAD SHX Text
AutoCAD SHX Text
12"DCW & 12"DHW DN TO LAV'S
AutoCAD SHX Text
1 "DCW DN 12"DCW DN TO WC'S
AutoCAD SHX Text
PROVIDE SHUT OFF VALVE 12" AFF
AutoCAD SHX Text
CW TO CCC-1, CCC-2 & CCC-3. REFER TO 1/M-102 FOR CONTINUATION
AutoCAD SHX Text
4"CW
AutoCAD SHX Text
4"CW
AutoCAD SHX Text
WHA
AutoCAD SHX Text
AutoCAD SHX Text
BFP
AutoCAD SHX Text
AutoCAD SHX Text
RISE TO CCC PIPING ELEVATION.
AutoCAD SHX Text
PROVIDE VALVE ON CW. PROVIDE CHAIN WHEEL FOR ACTIVATION FROM FLOOR
AutoCAD SHX Text
4"DCW
AutoCAD SHX Text
2"DCW
AutoCAD SHX Text
PROVIDE MIXING VALVE.
AutoCAD SHX Text
34"DCW DN TO UR
AutoCAD SHX Text
1"DHW
AutoCAD SHX Text
1"DCW
AutoCAD SHX Text
34"DCW & 34"DHW DN TO SH
AutoCAD SHX Text
12"DCW & 12"DHW
AutoCAD SHX Text
HS
AutoCAD SHX Text
AutoCAD SHX Text
SH
AutoCAD SHX Text
AutoCAD SHX Text
UR
AutoCAD SHX Text
AutoCAD SHX Text
EW
AutoCAD SHX Text
AutoCAD SHX Text
1"DCW 1"DHW
AutoCAD SHX Text
SEE DETAIL 2/P200
AutoCAD SHX Text
1 "DCW12"DCW
AutoCAD SHX Text
12"DCW & 12"DHW TO MIXING VALVE AND EW-1.
AutoCAD SHX Text
ROUTE AIR GAP DRAIN TO FD
AutoCAD SHX Text 2 "V12"V
AutoCAD SHX Text 2"V
AutoCAD SHX Text 1 "V12"V
AutoCAD SHX Text 2"V
AutoCAD SHX Text 1 "V12"V
AutoCAD SHX Text
LAV
AutoCAD SHX Text
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
WC
AutoCAD SHX Text
AutoCAD SHX Text
(TYP.-2)
AutoCAD SHX Text
HS
AutoCAD SHX Text
AutoCAD SHX Text
SH
AutoCAD SHX Text
AutoCAD SHX Text
UR
AutoCAD SHX Text
AutoCAD SHX Text
EW
AutoCAD SHX Text
AutoCAD SHX Text
SIDEWALL VENT TERMINAL. PROVIDE BIRD & INSECT SCREEN.
AutoCAD SHX Text 1 "V12"V
AutoCAD SHX Text 2"V
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text P100
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
%%USANITARY DRAINAGE PLAN
AutoCAD SHX Text DRAWING NOTES: : 1. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS REFER TO DRAWINGS MP-000 AND MP-001. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS REFER TO DRAWINGS MP-000 AND MP-001. 2. FLOOR CLEANOUT ASSEMBLIES, INCLUDING PLUGS, IN VEHICLE TESTING AREA SHALL BE H-20 FLOOR CLEANOUT ASSEMBLIES, INCLUDING PLUGS, IN VEHICLE TESTING AREA SHALL BE H-20 RATED FOR HEAVY-DUTY VEHICULAR TRAFFIC IN ACCORDANCE WITH ASME A112.36.2M. 3. COORDINATE ALL WORK ON THIS DRAWING WITH CIVIL DRAWINGS. COORDINATE ALL WORK ON THIS DRAWING WITH CIVIL DRAWINGS. 4. NOT ALL VALVES ARE SHOWN. PROVIDE SHUT-OFF VALVES, REDUCERS, AND WATER HAMMER NOT ALL VALVES ARE SHOWN. PROVIDE SHUT-OFF VALVES, REDUCERS, AND WATER HAMMER RESISTORS ON ALL BRANCH PIPING AS NEEDED. 5. REFER TO DWG P/300 FOR SANITARY RISER DIAGRAM.REFER TO DWG P/300 FOR SANITARY RISER DIAGRAM.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text P100
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
%%UDOMESTIC WATER PARTIAL PLAN
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text P100
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
%%USANITARY VENT PLAN