C7_Att08_Bid_Form.xlsx

XLSX spreadsheet 25 KB Posted

Attached to
Building 206 Lab Upgrade AND Building 233 Breakroom Renovation
Solicitation number
N0025326Q0011
Issued by

About this file

This is a Bid Form template for solicitation N0025326Q0011 for construction and renovation services at Naval Undersea Warfare Center (NUWC) Keyport, Washington. The form requires contractors to provide detailed pricing for two separate CLINs: Building 206 Lab Upgrade and Building 233 Restroom & Breakroom Renovation. Contractors must submit line-item pricing broken down by quantity, unit rate, and costs for materials, labor, and equipment for each task, with formulas calculating subtotals. The form includes example rows demonstrating the expected level of detail for an air handler installation and site mobilization/demobilization, which are provided for guidance only and must be deleted prior to submission. Additionally, the form requires contractors to account for subcontractor performance value, prime contractor and project management costs, and overhead and profit calculations including general home office overhead, field overhead, general and administrative expenses, profit margin, and bonding costs.

Contractors must complete all sections in accordance with the Statement of Work and adhere to the government's requirement that all formulas in total cells be preserved as formulas rather than hard-entered values. The solicitation is a 100% small business set-aside under NAICS code 238390 with a size standard of $19,000,000. Offerors must provide FOB Destination pricing to NUWC Keyport, WA 98345, and all quotes must be submitted via email to dane.a.jacobson3.civ@us.navy.mil and carly.beadle.civ@us.navy.mil. Company quote forms will not be accepted; all vendor offer details must be documented within this RFQ bid form.

View the file

Other files

File Type Posted
C7_PPI_Answers_Amendment0001.docx DOCX document
C7_Att12_206_233_SOW_Rev1.pdf PDF
C7_PPI_Answers_Amendment0001.docx DOCX document
N0025326Q0011_Amendment0001.pdf PDF
C7_Att02_Wage_Determination.pdf PDF
C7_Att01_Equipment_In_Place.xlsx XLSX spreadsheet
C7_Att03_Safety_Requirements_for_Contractors.pdf PDF
C7_Att04_Contractors_Guide_to_Env_Compliance.pdf PDF
C7_Att06_Schedule_of_Values.xlsx XLSX spreadsheet
Solicitation - N0025326Q0011.pdf PDF
C7_Att05_OPSEC_Guide.pdf PDF
C7_Att10_Safety_Data_Sheet.docx DOCX document
C7_Att12_Bldg206_and_Bldg233_SOW.pdf PDF
C7_Att11_OSHA_Calculating_Injury_and_Illness_Incident_Rate.pdf PDF
C7_Att07_Past_Performance_References.docx DOCX document
C7_Att09_PPI_Form.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bid Form

Bid Form Solicitation Number:N0025326Q0011Contractor:
PID Description:Building 206 Lab Upgrade and Building 233 Restroom & Breakroom RennovationDate:
Project Location:Naval Undersea Warfare Center, Keyport, WA
Note:Refer to Statement of Work
Instructions:Contractor to complete for all items required. Description should be sufficient to allow for technical and price evaluation in accordance with Section L instructions. Example rows are provided for guidance only to demonstrate the expected level of detail and should be deleted by contractor prior to completion.

Please leave all formulas utilized in calculating totals as formulas, rather than hard entering numbers in the "total" cells.

CLIN 0001QuantityUnitUnit RateMaterial TotalLabor TotalEquipment TotalLine Item TotalCLIN 0002QuantityUnitUnit RateMaterial TotalLabor TotalEquipment TotalLine Item Total
Building 206 Lab UpgradeBuilding 233 Restroom & Breakroom Rennovation
ITEMDESCRIPTION OF TASKSITEMDESCRIPTION OF TASKS
A (example)Air Handler1Unit$1,000.00$1,000.00$1,000.00A (example)Air Handler1Unit$1,000.00$1,000.00$1,000.00
A (example)Labor to Install Air Handler: HVAC Tech15Hrs$65.00$975.00$975.00A (example)Labor to Install Air Handler: HVAC Tech15Hrs$65.00$975.00$975.00
A (example)Labor to Install Air Handler: Electrician3Hrs$85.00$255.00$255.00A (example)Labor to Install Air Handler: Electrician3Hrs$85.00$255.00$255.00
A (example)Misc. Materials to install Air Handler (piping, ducting, electrical supplies, etc)1Lot$250.00$250.00$250.00A (example)Misc. Materials to install Air Handler (piping, ducting, electrical supplies, etc)1Lot$250.00$250.00$250.00
A (example)Equipment (scissor lift)2day$100.00$200.00$200.00A (example)Equipment (scissor lift)2day$100.00$200.00$200.00
B (example)Site mobilization/demobilization$0.00B (example)Site mobilization/demobilization$0.00
B (example)Labor for site mob/demob: General Laborer15Hrs$45.00$675.00$675.00B (example)Labor for site mob/demob: General Laborer15Hrs$45.00$675.00$675.00
B (example)Labor for site mob/demob: SSHO2Hrs$85.00$170.00$170.00B (example)Labor for site mob/demob: SSHO2Hrs$85.00$170.00$170.00
B (example)Equipment (Truck and Trailer to haul air handler and materials to job site)1day$450.00$450.00$450.00B (example)Equipment (Truck and Trailer to haul air handler and materials to job site)1day$450.00$450.00$450.00
B (example)Equipment (dump trailer for debris haul off)2day$250.00$500.00$500.00B (example)Equipment (dump trailer for debris haul off)2day$250.00$500.00$500.00
11
22
33
44
55
66
77
88
99
1010
1111
1212
1313
14<OFFEROR TO INSERT ROWS AS NECESSARY>14<OFFEROR TO INSERT ROWS AS NECESSARY>
Subcontractor Performance ValueSubcontractor Performance Value
Prime Contractor & Project Management CostsPrime Contractor & Project Management Costs
SubtotalSubtotal
General Home Office Overhead (%)General Home Office Overhead (%)
General Field Overhead (%)General Field Overhead (%)
General and Administrative (%)General and Administrative (%)
Profit (%)Profit (%)
BondBond
CLIN 0001 Firm Fixed Price Proposal AmountCLIN 0001 Firm Fixed Price Proposal Amount