The document is a comprehensive set of 61 engineering standard detail drawings for utility infrastructure created by the City of Casselberry Engineering Division in Florida, dated March 2019. These detailed drawings cover a wide range of utility engineering specifications including water mains, sanitary sewer systems, reclaimed water infrastructure, fire hydrants, valves, pump stations, pipe connections, backflow preventers, erosion control measures, fencing, and various installation techniques. The drawings provide precise technical guidance for constructing and maintaining municipal utility infrastructure, offering standardized designs for elements such as pipe bedding, trench configurations, concrete encasements, air release valves, thrust collars, and service connections.
The standard details are intended to ensure consistent engineering practices across utility projects in Casselberry, with each drawing meticulously specifying materials, dimensions, installation methods, and construction requirements. The drawings include technical specifications for different pipe materials, joint types, valve installations, meter configurations, and specialized infrastructure like grease interceptors and lift stations. Each detail is annotated with specific notes addressing material requirements, installation procedures, safety considerations, and compliance with relevant standards such as AWWA (American Water Works Association), ASTM, and Florida Department of Transportation (FDOT) specifications. The comprehensive nature of these drawings suggests they are designed to guide contractors, engineers, and municipal staff in implementing high-quality, standardized utility infrastructure projects.
View the file
Other files for this state and local contract opportunity
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE NOTE 2
2" MIN. ASPHALTIC CONCRETE
NOTES:
1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 98% OF THE MAXIMUM
DENSITY AS PER AASHTO T-180.
2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 98% OF THE MAXIMUM DENSITY AS
PER AASHTO T-180.
3. PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN ACCORDANCE
WITH TYPE A BEDDING AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED BY
THE CITY.
4. 15" MAX. FOR PIPE DIAMETERS LESS THAN 24" AND 24" FOR PIPE DIAMETER 24" AND
LARGER. THE MINIMUM DISTANCE SHALL EQUAL THE OUTSIDE DIAMETER OF THE PIPE.
5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE
FLOW.
7. REFER TO SECTION 6.05 OF THE UTILITY STANDARDS MANUAL FOR SHEETING AND
BRACING IN EXCAVATIONS. SHALL COMPLY WITH STATE OF FLORIDA TRENCH SAFETY
ACT.
8. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL
APPLICABLE REGULATIONS OF GOVERNING AGENCIES. SURFACE RESTORATION
WITHIN CITY RIGHT-OF-WAY SHALL COMPLY WITH REQUIREMENTS OF RIGHT-OF-WAY
UTILIZATION REGULATIONS.
SELECT
COMMON
FILL
UNDISTURBED
EARTH (SEE
NOTE 3)
SQUARE CUT EDGE
OF EXISTING
PAVEMENT (TYP)
FINISHED GRADE
CROWN TRENCH IN
UNPAVED AREAS. (3" MIN.)
(SEE NOTE 8 FOR
OTHER RESTORATION)
TRENCH WIDTH VARIES
W/ SIZE OF PIPE
ANGLE MAY VARY
SEE NOTE 4
PIPE O.D.
12" (TYP)
L
I F
T S
M
A X
I M
U M
S
E
N
O T
E
S
T
E
P I P
E
B
E D
D I N
G T
R E
N C
H
B
A C
K F
I L
L
GENERAL
DETAIL NO.
TYPE "B" BEDDING AND OPEN-CUT
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FIG. 1
DATE: 3/2019
NOTES:
1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 98% OF THE MAXIMUM DENSITY
AS PER AASHTO T-180.
2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 98% OF THE MAXIMUM DENSITY AS
PER AASHTO T-180.
3. USE OF TYPE A BEDDING TO BE DETERMINED IN THE FIELD AS DIRECTED BY THE CITY.
4. 15" MAX. FOR PIPE DIAMETER LESS THAN 24" AND 24" MAX. FOR PIPE DIAMETER 24" AND
LARGER. THE MINIMUM DISTANCE SHALL EQUAL THE OUTSIDE DIAMETER OF THE PIPE.
5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE
FLOW.
7. REFER TO SECTION 6.05 OF THE UTILITY STANDARDS MANUAL FOR SHEETING AND
BRACING IN EXCAVATIONS. SHALL COMPLY WITH STATE OF FLORIDA TRENCH SAFETY
ACT.
8. GRAVITY SEWERS SHALL UTILIZE TYPE A BEDDING IF REQUIRED BY THE CITY. BEDDING
DEPTH SHALL BE 4" MINIMUM FOR PIPE DIAMETER LESS THAN 15" AND 6" MINIMUM FOR
PIPE DIAMETER 16" AND LARGER.
9. DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF BEDDING
ROCK BELOW THE PIPE. THE CITY SHALL DETERMINE IN THE FIELD IF REMOVAL OF
UNSUITABLE MATERIAL IS REQUIRED TO REACH A SUITABLE FOUNDATION.
SQUARE CUT EDGE
OF EXISTING
PAVEMENT (TYP.)
FINISHED GRADE
SEE NOTE 2
12" (TYP)
PIPE BEDDING
(SEE NOTE 8 & 9)
UNDISTURBED
EARTH
BEDDING ROCK
SELECT
COMMON
FILL
PIPE O.D.
SEE NOTE 4
ANGLE MAY VARY
2" MIN. ASPHALTIC CONC.
CROWN TRENCH IN
UNPAVED AREAS. (3" MIN.)
(SEE NOTE 8 FOR OTHER
RESTORATION)
TRENCH WIDTH VARIES
W/ SIZE OF PIPE
L I F
X
I M
U M
T R
E N
C H
B
C
K F
I L L
S
T
E
P I P
E
B
E D
D I N
G
S
T
E
TYPE "A" BEDDING AND OPEN-CUT
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
DETAIL NO.
FIG. 2
1. (*): 15" MAX. FOR PIPE DIAMETER LESS THAN 24",
AND 24" MAX. FOR PIPE DIAMETER 24" AND
OVER. FOR CONCRETE ARCH, THE MIN. WIDTH
SHALL BE EQUAL TO OUTSIDE DIAMETER OF
PIPE.
2. "D" REFERS TO THE DIAMETER OF THE PIPE.
3. "T" REFERS TO THE THICKNESS OF THE PIPE.
4. THE NEED FOR CONCRETE ARCH HALF
ENCASEMENT OR FULL ENCASEMENT TO BE
DETERMINED IN THE FIELD AS DIRECTED BY
THE CITY.
5. REFER TO SECTION 6.05 OF THE UTILITY
STANDARDS MANUAL FOR SHEETING AND
BRACING EXCAVATIONS.
6. ENDS OF ENCASEMENT SHALL BE FORMED, AND
LOCATIONS SHALL BE INDICATED ON RECORD
DRAWINGS.
7. CONCRETE FOR ENCASEMENT SHALL BE fc OF
3000 PSI AT 25 DAYS.
FULL ENCASEMENTCONCRETE ARCH
CONCRETE CRADLE
UNDISTURBED
EARTH
SEE NOTE 1 (TYP.)
3000 P.S.I
CONCRETE
BEDDING
ROCK
4" MIN.
"D"
SHEETING
M I N
M I N
UNDISTURBED
EARTH
3000 P.S.I.
CONCRETE
SIDES CAN
BE FORMED
SEE NOTE 1 (TYP.)
UNSHEETED TRENCH
SHEETED TRENCH
10" MIN.
"D" 6"
MIN.
SHEETED TRENCH
UNSHEETED TRENCH
SHEETING
"D"/4
"D"/2
"T"
6" MIN.
UNDISTURBED
EARTH
3000 PSI
CONCRETE
SIDES CAN
BE FORMED
SEE NOTE 1 (TYP.)
"D" 6"
MIN.
10" MIN.
6"
FILE NAME:
CONCRETE ARCH AND ENCASEMENT
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 3
GENERAL NOTES:
1. THE TABLE REPRESENTS THE MINIMUM SEPARATION
REQUIREMENTS AS DESCRIBED IN F.D.E.P. RULES OF THE
FLORIDA ADMINISTRATION CODE (F.A.C. RULE 62-555.314).
THESE SEPARATION REQUIREMENTS SHALL APPLY BETWEEN
NEWLY PROPOSED UTILITY LINES AND EXISTING OR
PROPOSED UTILITY LINES.
2. FOR THE PURPOSE OF THIS TABLE, RECLAIMED WATER
SHALL MEAN UNRESTRICTED PUBLIC ACCESS REUSE WATER
AS DEFINED BY F.A.C. 17-610. OTHER TYPES OF RECLAIMED
WATER ARE CONSIDERED RAW SEWAGE AND SEPARATIONS
LISTED FOR SANITARY SEWER SHALL APPLY.
3. ALL SEPARATION DISTANCES ARE FROM OUTSIDE OF PIPE TO
OUTSIDE OF PIPE UNLESS OTHERWISE SPECIFIED.
CRITERION PRODUCING GREATER CLEARANCE SHALL BE
USED.
4. NO WATER PIPE SHALL PASS THROUGH OR COME IN
CONTACT WITH ANY PART OF A SANITARY OR STORM WATER
MANHOLE OR STRUCTURE.
5. A MINIMUM HORIZONTAL SEPARATION DISTANCE OF 10 FEET
BETWEEN WATER MAINS AND GRAVITY SEWERS OR FORCE
MAINS IS PREFERRED.
6. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN
WATER MAINS AND GRAVITY SEWER MAY BE REDUCED TO 3
FEET IF THE BOTTOM OF THE WATER MAIN IS LAID AT LEAST 6
INCHES ABOVE THE TOP OF THE SEWER.
7. FOR WATER MAINS CROSSING GRAVITY SEWER OR STORM
SEWERS, THE VERTICAL SEPARATION MAY BE REDUCED TO 6
INCHES IF THE WATER MAIN IS AT LEAST 6 INCHES ABOVE
THE GRAVITY OR STORM SEWER.
8. AT CROSSINGS OF WATER MAINS AND OTHER GRAVITY OR
PRESSURE MAINS, THE ONE FULL LENGTH OF WATER MAIN
SHALL BE INSTALLED ON THE CROSSING. WATER MAIN
SHOULD ALWAYS BE LAID ON TOP IN VERTICAL CROSSINGS.
9. ALTERNATIVELY, AT SUCH CROSSING, THE PIPES SHALL BE
ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST
3 FEET FROM ALL JOINTS IN STORM SEWERS, OR PIPELINES
CONVEYING RECLAIMED WATER AND AT LEAST 6 FEET FROM
ALL JOINTS IN GRAVITY OR PRESSURE - TYPE SANITARY OR
WASTEWATER FORCE MAINS.
10. WHERE ALLOWED BY THE F.D.E.P. PERMIT. ACCEPTABLE
ALTERNATIVE CONSTRUCTION FEATURES MAY INCLUDE
THE FOLLOWING:
A. WHERE AN UNDERGROUND WATER MAIN IS BEING LAID
LESS THAN THE REQUIRED MINIMUM HORIZONTAL
DISTANCE FROM ANOTHER PIPELINE AND WHERE AN
UNDERGROUND WATER MAIN IS CROSSING ANOTHER
PIPELINE AND JOINTS IN THE WATER MAIN ARE BEING
LOCATED LESS THAN THE REQUIRED MINIMUM
DISTANCE FROM JOINTS IN THE OTHER PIPELINE.
1. USE OF PRESSURE PIPE CONFORMING TO AMERICAN
WATER WORKS ASSOCIATION STANDARDS FOR THE
OTHER PIPELINE IF IT IS A GRAVITY OR VACUUM TYPE
PIPELINE;
2. USE OF WELDED, FUSED, OR OTHERWISE
RESTRAINED JOINTS FOR EITHER THE WATER MAIN
OR THE OTHER PIPELINE; OR
B. WHERE AN UNDERGROUND WATER MAIN IS BEING LAID
LESS THAN 3 FEET HORIZONTALLY FROM ANOTHER
PIPELINE AND WHERE AN UNDERGROUND WATER MAIN
IS CROSSING ANOTHER PIPELINE AND IS BEING LAID
LESS THAN THE REQUIRED MINIMUM VERTICAL
DISTANCE FROM THE OTHER PIPELINE;
1. USE OF PIPE, OR CASING PIPE, HAVING HIGH IMPACT
STRENGTH (i.e. HAVING AN IMPACT STRENGTH AT
LEAST EQUAL TO THAT OF 0.25 INCH THICK DUCTILE
IRON PIPE) OR CONCRETE ENCASEMENT AT LEAST 4
INCHES THICK FOR WATER MAIN OR THE OTHER
PIPELINE IF IT IS NEW AND IS CONVEYING
WASTEWATER OR RECLAIMED WATER.
HORIZONTAL & VERTICAL SEPARATION REQUIREMENTS
PROPOSED
UTILITY
POTABLE
WATER
RECLAIMED*
WATER
SANITARY
SEWER
STORM
SEWER
POTABLE WATER RECLAIMED WATER*
SANITARY SEWER
(GRAVITY & F.M.)
STORM SEWER
ACCEPTABLE
VARIANCES
SEE GENERAL
NOTES:
NO. 5, 6, 7
AND NO. 9
VERT.HORIZ.VERT.HORIZ.VERT.HORIZ.VERT.HORIZ.
3'
10'
3' 12"
12"
12"
3'
3'
3'
12"
12"
3' 12'
12"
3'
12" 10' 12" 10' 12"
FILE NAME:
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 4
HORIZONTAL & VERTICAL
SEPARATION REQUIREMENTS
( FULL LENGTH )
EXIST P.V.C.
RESTRAINED JOINT (TYP.)
12"
(4 REQUIRED)
PROP. STORMWATER
45 D.I.P. OR P.V.C. BENDS
M I N
VARIES
TRANSITION GASKET
SOLID SLEEVE WITH
FINISHED GRADE
NOTES:
( FULL LENGTH )
EXIST P.V.C.
12"
M
I N
C
O V
E R
OR SANITARY SEWER
RESTRAINED AS REQUIRED
BY MANUFACTURER.
MAIN
CONCRETE ENCASEMENT OF SANITARY SEWER IS AN ALTERNATIVE METHOD
OF ADDRESSING A CONFLICT WHEN UNABLE TO MAINTAIN 18" VERTICAL
SEPARATION DISTANCE. IN SUCH INSTANCES, THE MINIMUM PIPE VERTICAL
SEPARATION SHALL BE 12".
1. LOWERING OF EXISTING WATER MAIN & FORCE MAIN BY DEFLECTION METHOD ACCEPTABLE
IF EXISTING FIELD CONDITIONS PERMIT.
2. LENGTH OF SECTION BASED ON MINIMUM LENGTH AS DETERMINED BY DIPRA RESTRAINED
JOINT MANUAL.
3. INSTALL RESTRAINED JOINTS, AS REQUIRED, FROM DEFLECTION POINT IN BOTH DIRECTIONS.
FILE NAME:
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 5
STORM DRAINAGE PIPE OR
SANITARY SEWER MAIN CONFLICT
6" 8" 24"16"
PIPE SIZE
10" 12" 18" 30" 4"
RESTRAINED PIPE TABLE
WATER, RECLAIMED WATER MAINS & WASTEWATER FORCE MAINS
NOTES:
1. FITTINGS SHALL HAVE RESTRAINED JOINTS UNLESS OTHERWISE INDICATED.
2. INSTALL FULL LENGTH JOINTS WITH TOTAL LENGTH EQUAL TO OR GREATER THAN
LENGTH SHOWN IN THE TABLE.
3. WHERE TWO OR MORE FITTINGS ARE IN SERIES, SELECT FITTING RESTRAINT LENGTH THAT
YIELDS THE LONGEST RESTRAINT DISTANCE.
4. ALL INLINE VALVES SHALL BE RESTRAINED.
5. LENGTHS SHOWN IN THE TABLE WERE CALCULATED IN ACCORDANCE WITH
PROCEDURES OUTLINED IN "THRUST RESTRAINT DESIGN FOR DUCTILE IRON PIPE"
GUIDELINES PUBLISHED BY DIPRA, USING THE ASSUMPTIONS SHOWN BELOW:
WORKING PRESSURE: 100 PSI - WATER AND RECLAIMED WATER MAINS
TEST PRESSURE: 150 PSI (WATER, RECLAIMED, WASTEWATER PIPES)
SOIL DESIGNATION: SP (SAND / SILT)
LAYING CONDITIONS: 2
FACTOR OF SAFETY: 1:5
6. FOR PIPE ENCASED IN POLYETHYLENE, INCREASE THE GIVEN VALUE BY A FACTOR OF 1.5
7. THE DESIGN ENGINEER SHALL INCREASE THE VALUES IN THE TABLE AS WARRANTED
BY SITE-SPECIFIC SOIL DESIGNATIONS, LAYING CONDITIONS, PIPE MATERIAL, ETC.
90° BEND
45° BEND
22-1/2° BEND
11-1/4° BEND
PLUG OR
BRANCH OF TEE
VALVE OR PLUG
REDUCER VARIES BY SIZE; TO BE DETERMINED BY THE DESIGN ENGINEER.
29 38 916645 52 73 107
12 16 382819 22 30 45
6 8 19149 11 15 22
3 4 975 6 8 11
39 57 17612073 89 134 214
61 80 20014396 112 157 238
FILE NAME:
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 6
RESTRAINED PIPE TABLE
POTABLE AND RECLAIMED WATER MAINS
AND WASTEWATER FORCE MAINS
ENCASE TIE RODS IN
1-1/2" PVC SLEEVE
UNDISTURBED
EARTH
#4 BARS
4" x 4" x 1/2"
HOT DIPPED GALVANIZED
OR STAINLESS STEEL
BEARING PLATE (TYP.)
MECHANICAL JOINTS
TIE RODS INCLUDING
NUTS AND WASHERS
(SEE SCHEDULE BELOW)
C (6" MIN.)
SEE TRENCH DETAILS
FOR PIPE BEDDING
REQUIREMENTS
3" COVER
D (4'-0" MIN.)
#4 BARS ALL AROUND
(MIN. 2" CLEARANCE
AROUND PIPE.)
6" MIN. (TYP.)
18" MIN.
NOTES:
1. ADDITIONAL REINFORCEMENTS SHALL BE AS
SPECIFIED BY THE ENGINEER.
2. MINIMUM COMPRESSIVE STRENGTH FOR
CONCRETE SHALL BE 3000 P.S.I.
3. BEDDING, BACKFILL, AND COMPACTION SHALL
BE AS SPECIFIED ELSEWHERE IN THE
STANDARD DRAWINGS.
4. ALL FORM BOARDS SHALL BE REMOVED PRIOR
TO BACKFILL.
5. NO ALLOWANCE SHALL BE MADE FOR FRICTION
BETWEEN THE PIPE WALL AND THE THRUST
COLLAR.
6. DESIGN PRESSURE: 150 P.S.I.
7. REQUIRED FOR LINE STOPS.
* USE ONLY WHEN APPROVED IN WRITING BY CITY.
NOTE: THRUST COLLAR AREAS TO BE COMPUTED ON BASIS OF
2000 LBS/SF SOIL RESTRAINT BEARING.
SCHEDULE OF DIMENSIONS AND MATERIALS *
PIPE
SIZE
(INCHES)
DIMENSIONS TIE RODS REQ'D
9.0
8.0
6.0
5.0
3.5
2.5
2.0
A B C D DIA. NO.
83/4
3/4
3/4
3/4
3/4
3/4
3/41.02.0
2.5 1.0
1.03.0
3.0
4.0
5.0
6.0 1.5
1.5
1.5
1.0
TRENCH
LIMITS
FILE NAME:
WATER MAIN THRUST COLLAR
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 7
1. CASING SHALL EXTEND A MINIMUM OF TEN FEET BEYOND THE EDGE OF
PAVEMENT OR MEET FDOT REQUIREMENTS, WHICHEVER IS GREATER. WHERE
PRACTICAL, CASING SHALL EXTEND 10 FEET BEYOND EDGE OF PAVEMENT AND
SHALL NOT BE LESS THAN 6 FEET BEYOND EDGE OF PAVEMENT IN ANY CASE.
THE CITY MAY REQUIRE LONGER CASING FOR DEEPER BORES.
2. WHEN CONSTRUCTION IS WITHIN FDOT JURISDICTION, ADDITIONAL
REQUIREMENTS OF THE "FDOT UTILITY ACCOMMODATION GUIDE" SHALL BE
MET. WHEN CONSTRUCTION IS WITHIN COUNTY JURISDICTION MUST FOLLOW
COUNTY REQUIREMENTS.
3. DISTANCE BETWEEN SPACERS TO BE PER MANUFACTURER'S SPECIFICATIONS,
OR MAX OF 6.5', WHICHEVER IS MORE STRINGENT.
4. USE OF FLOWABLE FILL IN THE ANNULAR SPACE BETWEEN THE CASING AND
CARRIER PIPE IS PROHIBITED.
5. PIPE IN CASING SHALL HAVE A MECHANICAL BELL RESTRAINT HARNESS WHERE
RODS ARE DOUBLE NUTTED TO PRECLUDE OVERBELLING THE JOINT DURING
PUSHING CARRIER PIPE CASING.
6. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CASING INSTALLATION
TO ENGINEER FOR REVIEW PRIOR TO INSTALLATION.
7. SEAL BOTH ENDS OF CASING WITH 12" BRICK AND NON-SHRINK GROUT
(MINIMUM)
8. ROTATION OF CARRIER PIPE INSIDE THE CASING WILL NOT BE PERMITTED.
2" OR 3" MIN.
CLEARANCE
SEE NOTES
SEE NOTE 5
FOR THESE
SKIDS
D1= DIA. OF
CARRIER PIPE
CARRIER PIPE NOM. DIA. (D1)
CASING PIPE NOM. DIA. (D2)
WALL THICKNESS-INCHES
CARRIER PIPE AND CASING PIPE SIZES (MIN.)
PER AUTHORITY HAVING JURISDICTION
18 22
14 16
54 60
36 48
30 36
ANNULAR SPACE MAY
REMAIN EMPTY, SEAL
BOTH ENDS WITH 12"
THICK CLASS "C"
CONCRETE PLUGS
D2 DIA. OF CASING
D1
PIPE SEE NOTE 4
STEEL CASING
PIPE, WELDED
ANSI STD. A-21.51
BELL OF CARRIER PIPE
POLYETHYLENE CASING
SPACERS) OR
STAINLESS STEEL SPACERS
W/POLY RUNNERS OR APPROVED EQUAL.
FILE NAME:
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 8
BORING AND JACKING
AND
CONDUIT CROSSING
1. BRONZE IDENTIFICATION DISC SHALL BE REQUIRED FOR ALL VALVES AS
REQUIRED BY CITY.
2. EXACT SHAPE AND SIZE OF BRONZE DISC SHALL BE A MINIMUM OF 3" IN
DIAMETER AND
" THICK WITH A 2" ANCHOR.
3. CONCRETE FOR COLLAR SHALL BE FC OF 2,500 PSI MINIMUM @ 28 DAYS.
4. VALVE BOX TOP AND COLLAR SHALL BE EVEN WITH SOD, WITH GRADING
TRANSITIONED OVER 5'.
5. VALVE BOX COLLAR SHALL INCLUDE 2" PVC PIPE FOR LOCATE WIRE AND 2" FLAT
BRASS CAP.
SZ: SIZE OF THE MAIN.
TYPE: TYPE OF VALVE
SERVICE: WATER, RECLAIMED OR SANITARY
DIR. & TR.: DIRECTION TO OPEN AND # OF TURNS
Sz
Type
Service
Dir. & Tr.
BRONZE DISC
ANCHORS (TO
BE APPROVED
BY CITY)
3" DIA. BRONZE 2"
THICK DISC ANCHORED
IN CONC. PAD-STAMP
AS REQUIRED
#4 REBARS
ALL AROUND
24" x 24" x 6" THICK
CONC. PAD (FLUSH
WITH FINISHED GRADE)
3" DIA. BRONZE DISC
ANCHORED IN CONC.
PAD STAMP AS REQ'D.
SIZE OF VALVE
TYPE OF VALVE
SERVICE
DIRECTION & NO.
TURNS TO OPEN
APPLICABLE VALVE
BOX AND COVER
(SEE FIG. 14)
3000 P.S.I.
CONC. MIN.
2"
MIN.
12"
2-1/2"
FLOW
VALVE BOX
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 9
NOTE:
PRESSURE
MAIN
AND ROUND LID
AND UPPER GUIDE REQUIRED
VALVE BOX COVER
ADJUSTABLE CAST IRON
FOR MORE THAN 4 FT. DEPTH.
ASSEMBLY, 2" SQ. WRENCH NUT
ADJUSTABLE VALVE EXTENSION
M
A X
M
I N
I M
U
SLEEVE
D
P
T H
6" C-900 PVC
RESTRAINED JOINTS REQUIRED
AT ALL VALVE LOCATIONS
IRON VALVE BOX
(USE WITH CAST
ONLY)
4' EXCESS WIRE
WRENCH NUT OPEN
COUNTER-CLOCK WISE
AWWA C509 & 515 DUCTILE IRON BODIED EPOXY COATED RESILIENT
WEDGE GATE VALVE WITH 2" OPERATING NUT.
16"x16"x6" (MIN.) PRECAST
BLOCK OR MIN.
6" THICK #57 STONE
A CONTINUOUS No. 10
COPPERHEAD TRACER
WIRE COLOR CODED
PURPLE
#4 RE-BAR
24"X24" SQUARE BY
6" THICK CAST-IN-PLACE CONC.
COLLAR WITH # 4
RE-BAR RING AT CENTER
2" PVC W/2" FLAT BRASS CAP
1. BOLT VALVES TO TEE OR CROSS WHEREVER AND WHENEVER APPLICABLE.
2. A CONTINUOUS TRACER WIRE TO BE COLOR CODED "PURPLE" FOR RECLAIMED WATER, LAYED ON TOP IN TRENCH.
3. GATE VALVE WEDGE SHALL BE COMPLETELY ENCAPSULATED WITH EPDM RUBBER.
4. ALL EXTERIOR BOLTS, NUTS, WASHERS AND HARDWARE SHALL BE MINIMUM OF 316 STAINLESS STEEL GRADE.
5. PVC EXTENSIONS (C900) MAY BE USED ON VALVE BOX INSTALLATION.
VALVE AND VALVE BOX
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 10
SET TOP OF VALVE BOX
TO FINISHED GRADE
COVER (SEE FIGURE 14)
CONCRETE PAD IN UNPAVED
AREAS (SEE FIGURE 9)
FINISHED GRADE
SEE NOTE 2
RESILIENT SEAT M.
J. GATE VALVE
WATER MAIN
ADJUSTABLE CAST
IRON VALVE BOX
BOX SHALL REST ON BEDDING ROCK
NOT ON VALVE OR PIPE AND SHALL BE
CENTERED ON OPERATING NUT
6" BEDDING ROCK
10 THHN TRACING WIRE
ALONG ALL PIPE COIL
EXCESS TRACING WIRE
IN BOX
NOTES:
1. PVC EXTENSIONS (C900) MAY BE USED ON VALVE BOX INSTALLATION.
2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO
WITHIN 4 FOOT DEPTH BELOW FINISHED GRADE.
GATE VALVE AND BOX
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 11
1. PVC EXTENSIONS MAY BE USED ON VALVE BOX INSTALLATION.
2. ALL WATER SHUT-OFF VALVES SIXTEEN (16) INCHES AND
LARGER SHALL BE BUTTERFLY VALVES. SEE SECTION 52.3 OF
THE UTILITIES MANUAL.
3. VALVE NUT SHOULD NOT EXCEED 3' IN DEPTH.
* WHEN APPROVED IN WRITING BY CITY.
BEDDING ROCK
UNDISTURBED
EARTH
WIRE NEEDS TO BE TO
SIDE THROUGH 2" PORT
ADJUSTABLE CAST
IRON VALVE BOX
LOCATING WIRE
FINISHED GRADE
VALVE PAD IN
UNPAVED AREAS
(SEE FIGURE 9)
COVER (SEE FIGURE 14)
BUTTERFLY
VALVE
BACKFILL
M
I N
BUTTERFLY VALVE AND BOX
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 12
PRESSURE
MAIN
AND ROUND LID
AND UPPER GUIDE REQUIRED
VALVE BOX COVER
ADJUSTABLE CAST IRON
FOR MORE THAN 3 FT. DEPTH.
ASSEMBLY, 2" SQ. WRENCH NUT
ADJUSTABLE VALVE EXTENSION
M
A X
M
I N
I M
U
SLEEVE
P
T H
"SEWER" (PAINTED GREEN) ON TOP
OF CONCRETE COLLAR.
TO FINISHED GRADE & FLUSH
SET TOP OF VALVE BOX
6" C-900 PVC
RESTRAINED JOINTS REQUIRED
AT ALL VALVE LOCATIONS
IRON VALVE BOX
(USE WITH CAST
ONLY)
4' EXCESS WIRE
WRENCH NUT OPEN
COUNTER-CLOCK WISE
AWWA C509 & 515 DUCTILE IRON BODIED EPOXY COATED RESILIENT
WEDGE GATE VALVE WITH 2" OPERATING NUT.
16"x16"x6" (MIN.) PRECAST
BLOCK OR MIN.
6" THICK #57 STONE
A CONTINUOUS No. 10
COPPERHEAD TRACER
WIRE COLOR CODED
BLUE
#4 RE-BAR
24"X24" SQUARE BY
6" THICK CAST-IN-PLACE CONC.
COLLAR WITH # 4
RE-BAR RING AT CENTER
2" PVC W/2" FLAT BRASS CAP
1. BOLT VALVES TO TEE OR CROSS WHEREVER AND WHENEVER APPLICABLE.
2. A CONTINUOUS TRACER WIRE TO BE COLOR CODED "BLUE" FOR WATER, LAYED ON TOP IN TRENCH.
3. GATE VALVE WEDGE SHALL BE COMPLETELY ENCAPSULATED WITH EPDM RUBBER.
4. ALL OUTSIDE HEX NUTS, BOLTS AND HARDWARES (EXCEPT MECHANICAL BOLTS SUCH AS "T" BOLTS)
SHALL BE MIN. 316 STAINLESS STEEL GRADE.
5. PVC EXTENSIONS (C900) MAY BE USED ON VALVE BOX INSTALLATION.
6. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO WITHIN 4 FOOT DEPTH BELOW
FINISHED GRADE.
PLUG VALVE AND BOX
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 13
RECLAIMED WATER SEWER
FIREPOTABLE WATER
NOTE:
APPLY TWO COATS OF EXTERIOR ENAMEL PAINT:
PURPLE - RECLAIMED WATER
GREEN - SEWER
BLUE - POTABLE WATER
RED - FIRE
RECLAIMED
WATER
SEWER
WATER FIRE
TYPICAL VALVE BOX COVER
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 14
M
I N
P.V.C. OR D.I.P. PIPE
M
I N
M
A X
A CONTINUOUS No. 10 COPPERHEAD
TRACER WIRE (COLOR CODED
"BLUE") ON TOP OF PIPE IN TRENCH
EARLY WARNING TAPE
A. ALL UTILITY PIPE, SHALL BE INSTALLED WITH 2 INCH WIDE VINYL CONTINUOUS TAPE, FOR
IDENTIFICATION AND WARNING PURPOSES, BURIED ABOVE THE PIPE AT A MAXIMUM
DEPTH DEPTH OF 18 INCHES OR AS APPROVED BY THE CITY. IT SHALL BE COLOR CODED
AND WORDED AS FOLLOWS:
NOTES:
1. A CONTINUOUS No. 10 COPPERHEAD TRACER WIRE TO BE INSTALLED WITH ALL PIPE.
WIRE SHALL BE BROUGHT UP TO GRADE AT ALL VALVES OUTSIDE P.V.C. SLEEVE, (SEE
DETAIL 5).
2. ALL TRACER WIRES SHALL BE INTERCONNECTED WITH WATER PROOF WIRE NUT CAP OR
WITH SIMILAR WATER PROOF SPLICE KIT AT ANY SPLICE AND WHERE SERVICES CONNECT
TO MAINS.
3. A SUCCESSFUL CONTINUITY TEST SHALL BE CONDUCTED AND WITNESSED BY A CITY
INSPECTOR AT THE COMPLETION OF TRACER WIRE INSTALLATION.
4. HORIZONTAL DIRECTIONAL DRILL INSTALLATIONS OF PIPE REQUIRE 3 LOCATE WIRES.
1. POTABLE WATER
A. COLOR: BLUE WITH BLACK LETTERING.
B. LETTERING: "CAUTION: WATER LINE
BURIED BELOW" OR SIMILAR WORDING.
2. RECLAIMED WATER
A. COLOR:PURPLE WITH WHITE LETTERING.
B. LETTERING: "CAUTION: RECLAIMED WATER
LINE BURIED BELOW" OR SIMILAR WORDING.
3. GRAVITY SEWER
4. SEWER FORCE MAIN
A. COLOR: GREEN WITH BLACK LETTERING.
B. LETTERING: "CAUTION: SEWER LINE
BURIED BELOW" OR SIMILAR WORDING.
A. COLOR: BROWN WITH BLACK LETTERING.
B. LETTERING: "CAUTION: SEWER FORCE MAIN
BURIED BELOW" OR SIMILAR WORDING.
"TERRA TAPE D" or SIMILAR
3" WIDE CONTINUOUS FOIL LOCATOR TAPE
WITH THE FOLLOWING LABELS AND COLORS:
"CAUTION BURIED WATER LINE BELOW"/BLUE
LOCATOR TAPE / TRACER WIRE
INSTALLATION FOR PIPELINES
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 15
4" - 6" - 2" PIPE TAPE IS CENTERED ALONG TOP HALF OF PIPE
TAPE SHALL BE GREEN WITH BLACK LETTERING
TAPE SHALL RUN FROM JOINT TO JOINT ALONG THE LENGTH OF THE PIPE
PAPER BACKED ADHESIVE VINYL TAPE (TYPICAL)
8" - 16" PIPE - 2"TAPE IS PLACED ALONG BOTH SIDES OF TOP HALF OF PIPE
SEWER LINESEWER LINE SEWER LINE
SEWER LINE
DUCTILE IRON FORCE MAIN AND GRAVITY LINES
WITH IDENTIFICATION TAPE
12"
SEWER LINE
MAX.
SEWER LINE
SEWER LINE
SEWER LINE
SEWER LINE
NTS
1"
SEWER LINE
SEWER LINE
SEWER LINE
SEWER LINE
SEWER LINE
SEWER LINE
PVC FORCE MAIN AND GRAVITY LINES
SEWER LINE
SEWER LINE
SEWER LINE SEWER LINE
SEWER LINE
TYPICAL METAL PIPE
NTS
21"
MAX.
SEWER FORCE MAIN
ORCE
SEWER FORCE MAIN
SPECIFIED
PER PIPE
DIAMETER
GRAVITY SEWER: SOLID LIGHT GREEN
OR WHITE PVC WITH LIGHT GREEN
LETTERING.
FORCE MAIN: WHITE WITH BROWN
LETTERING.
1) PIPE IDENTIFICATION LETTERING:
A. FORCE MAIN: SEWER FORCE MAIN
B. GRAVITY SEWER: SEWER LINE
2) THE LETTERING SHALL APPEAR ON 3
SIDES OF THE PIPE AND RUN THE
ENTIRE LENGTH OF THE PIPE.
3) LETTERING A MIN. OF 3/4 INCH IN
HEIGHT AND APPEARING NOT LESS
THAN ONCE EVERY 21 INCH IN-
TERVAL SHALL RUN THE LENGTH OF
THE PIPE.
4) LETTERING MUST BE PERMANENTLY
IMPREGNATED INTO THE PVC (IT
CAN NOT BE STENCILED ONTO THE
SURFACE).
20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF THE TOP HALF OF THE PIPE
WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE
PIPE IDENTIFICATION
(SEWER - FORCE MAIN AND GRAVITY)
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 16
DUCTILE IRON RECLAIMED WATER MAIN WITH IDENTIFICATION TAPE
RECLAIMED WATER MAIN RECLAIMED WATER MAIN RECLAIMED WATER MAIN
PANTONE PURPLE 522C PVC
WATER
3/4"
21" MAX.
PVC RECLAIMED WATER MAIN
TYPICAL METAL PIPE
2.0" - 4" PIPE -2" TAPE IS CENTERED ALONG TOP HALF OF PIPE
RECLAIMED WATER MAIN RECLAIMED WATER MAIN
20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF TOP HALF OF PIPE
WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE
12"
MAX.
6' - 16" PIPE - 2" TAPE IS PLACED ALONG BOTH SIDES OF
THE TOP HALF OF PIPE
SPECIFIED
PER PIPE
DIAMETER
RECLAIMED WATER MAINRECLAIMED WATER MAINRECLAIMED WATER MAIN
RECLAIMED WATER MAINRECLAIMED WATER MAINRECLAIMED WATER MAIN
RECLAIMED WATER MAINRECLAIMED WATER MAIN
RECLAIMED WATER MAIN
RECLAIMED WATER MAIN RECLAIMED WATER MAIN RECLAIMED WATER MAIN
RECLAIMED WATER MAIN
RECLAIMED WATER MAIN RECLAIMED WATER MAIN
RECLAIMED WATER MAIN
RECLAIMED WATER MAIN1"
RECLAIMED WATER MAIN
NTS
NTS
1) LETTERING SHALL APPEAR ON 3 SIDES
OF THE PIPE AND RUN THE ENTIRE
LENGTH OF THE PIPE.
2) LETTERING SHALL BE A MINIMUM OF
3/4 INCH IN HEIGHT AND APPEAR
ONE OR MORE TIMES EVERY 21
INCHES ALONG THE LENGTH OF THE
PIPE.
3) LETTERING MUST BE PERMANENTLY
IMPREGNATED INTO THE PVC (IT
CAN NOT BE STENCILED ONTO THE
SURFACE OF THE PIPE).
4) LETTERING SHALL BE WHITE OR
OTHER CONTRASTING COLOR.
PURPLE TAPE WITH WHITE OR OTHER CONTRASTING PERMANENTLY
IMPREGNATED LETTERING SHALL BE USED. THE TAPE SHALL RUN
FROM JOINT TO JOINT ALONG THE LENGTH OF THE PIPE
PIPE IDENTIFICATION
(RECLAIM WATER)
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 17
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
WITH IDENTIFICATION TAPE
DUCTILE IRON POTABLE WATER MAIN
6" - 16" PIPE - 2" TAPE IS PLACED ALONG BOTH SIDES OF TOP HALF OF PIPE
2.0" - 4" PIPE - 2" TAPE IS CENTERED ALONG TOP HALF OF PIPE
20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF THE TOP HALF OF THE PIPE
WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE
BLUE TAPE WITH BLACK PERMANENTLY IMPREGNATED LETTERING
SHALL BE USED. THE TAPE SHALL RUN FROM JOINT TO JOINT ALONG THE PIPE
PVC POTABLE WATER MAIN
WATER MAIN
12"
MAX.
NTS
POTABLE WATER MAIN
1"
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
NTS
POTABLE WATER MAIN
SPECIFIED
PER PIPE
DIAMETER
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
POTABLE WATER MAIN
TYPICAL METAL PIPE
POTABLE WATER MAIN
BLUE PVC WITH
MAIN POTABLE WATER MAIN
21"
MAX.
POTABLE
1) LETTERING SHALL APPEAR ON THREE
SIDES OF THE PIPE AND RUN THE
ENTIRE LENGTH OF THE PIPE.
2) LETTERING SHALL BE A MINIMUM 3/4"
IN HEIGHT AND APPEAR ONE OR
MORE TIMES EVERY 21 INCHES ALONG
THE LENGTH OF THE PIPE.
3) LETTERING MUST BE PERMANENTLY
IMPREGNATED INTO THE PVC (IT
CAN NOT BE STENCILED ONTO
THE SURFACE OF THE PIPE.
4) LETTERING SHALL BE BLUE ON
WHITE PVC OR WHITE ON BLUE
PVC.
WHITE LETTERING
OR WHITE PVC
WITH BLUE LETTERING
3/4"
WATER
PIPE IDENTIFICATION
(POTABLE WATER)
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 18
NOTES:
1. ABOVE DETAIL IS BASED ON 2 INCH COMBINATION
AIR/VACUUM RELEASE VALVE. CHANGE PIPE AND
FITTINGS ACCORDINGLY FOR OTHER VALVE SIZES
AND TYPES. VALVE SIZES TO BE DETERMINED BY
THE ENGINEER AND APPROVED BY THE CITY PRIOR
TO INSTALLATION.
2. THE MINIMUM DIMENSION FROM TOP OF PIPE TO
FINISHED GRADE SHALL BE 4.O FEET.
3. ALL STRUCTURES TO BE TRAFFIC BEARING RATED.
4. FOR USE ON WATER, RECLAIMED, OR FORCE MAINS
AS REQUIRED BY THE ENGINEER AND OR CITY
ENGINEER.
5. ALL FITTINGS AND PIPE SHALL BE BRASS, UNLESS
APPROVED BY CITY.
6. ALL STRUCTURES TO BE TRAFFIC BEARING RATED.
4' x 4' PRECAST
CONCRETE VAULT
CAST IRON FRAME
AND COVER WITH
ACCESS LID.
GROUT
2" VALVE (TYP.)
2" PORT WITH
THREADED PLUG
CUT OUT AND SEAL JOINT
WITH MORTAR FOR FORCE
MAIN OR WATER MAIN
SEE NOTE 2
SERVICE SADDLE
8" x 16" REINFORCED
CONCRETE FOOTING.
(INTEGRAL WITH
PRECAST STRUCTURE)
6"
6"
36" SQ.
17-1/4"
FINISHED
GRADE
4" MAX.
PREMOLDED PLASTIC
JOINT FILLER
5" WALLS (MIN.)
PIPE PLUG (TYP.)
2" NIPPLE
2" BRASS
CORPORATION STOP
2" NIPPLE
FITTINGS AND
PIPE FOR A.R.V.
SHALL BE BRASS
BEDDING ROCK
FILE NAME:
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 19
AIR OR COMBINATION AIR / VACUUM
RELEASE VALVE IN VAULT
NOTES:
1. ABOVE DETAIL IS BASED ON 2 INCH COMBINATION
AIR/VACUUM RELEASE VALVE. CHANGE PIPE AND FITTINGS
ACCORDINGLY FOR OTHER VALVE SIZES AND TYPES. VALVE
SIZES TO BE DETERMINED BY THE ENGINEER AND APPROVED
BY THE CITY PRIOR TO INSTALLATION.
2. THE MINIMUM DIMENSION FROM ELBOW INVERT TO FINISHED
GRADE SHALL BE 4.0 FEET UNLESS OTHERWISE APPROVED
BY PUBLIC WORKS.
3. THE AIR RELEASE VALVE SHALL BE ADEQUATELY
SUPPORTED.
4. ALL FITTINGS AND PIPE SHALL BE BRASS, UNLESS APPROVED
BY CITY.
5. ALL STRUCTURES TO BE TRAFFIC BEARING RATED.
6. FOR USE ON WATER, RECLAIMED, OR FORCE MAINS AS
REQUIRED BY THE ENGINEER AND OR CITY ENGINEER.
4" MAX.
PRE-MOLDED PLASTIC
JOINT FILLER
PIPE PLUG (TYP.)
2" NIPPLE
2" BRASS
CORPORATION STOP
2" NIPPLE
2" 90° BEND
6" BEDDING ROCK
8" x 16" REINFORCED
CONCRETE FOOTING.
SERVICE SADDLE
WASTEWATER
FORCE MAIN OR
WATER MAIN
2" BRASS
CORPORATION STOP
2" BRASS PIPE
2" NIPPLE
2" 90° BEND
EXTENSION ROD
AS REQUIRED
CAST IRON VALVE
BOX TOP SECTION
2" OPERATING NUT
EXISTING/
PROPOSED
PAVEMENT
CAST IRON FRAME
AND COVER WITH
ACCESS LID.
GROUT
FINISHED GRADE
2" VALVE (TYP.)
5" WALL (MIN.)
2" PORT WITH
THREADED PLUG
SEE NOTE 3
GROUT
2"
UNION
CONCRETE VAULT
36" SQ.
17-1/4"
4' x 4' PRECAST
FILE NAME:
OFFSET AIR OR COMBINATION AIR /
VACUUM RELEASE VALVE
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 20
M A T E R I A L S
QUANT.
ITEM
DESCRIPTION
VENTED ENCLOSURE AS APPROVED
AIR RELEASE VALVE 2" NPT AS APPROVED
1" CURB STOP, S.S.
2" x 4" NIPPLE, S.S.
2" BALL VALVE, S.S.
2" TEE, S.S.
2" X 1" REDUCER, S.S.
1" SHORT NIPPLE, S.S.
2" PIPE, S.S. LENGTH AS REQUIRED
2" DOUBLE STRAP TAPPING SADDLE, S.S.
4" & LARGER PIPE, D.I. OR PVC (DR-18)
2" CORPORATION BRASS
1-1/2" PIPE, PVC, LENGTH AS REQUIRED
1-1/2" x 90° ELBOW, PVC
1 CONCRETE SLAB AROUND ENCLOSURE
16 1 #57 WHITE ROCK
SEWER AIR RELEASE VALVES SHALL BE AS APPROVED
WATER AIR RELEASE VALVES SHALL BE AS APPROVED
NOTE:
VENTED ENCLOSURE TO BE
COLOR CODED AS FOLLOWS:
WATER MAIN - BLUE
FORCE MAIN - GREEN
REUSE MAIN - PURPLE
FINISHED GRADE
PAD SIZE 36"x36"
NOTE:
1. BUILT (ALL FITTINGS) OUT OF BRASS.
2. ONLY ALLOWED IN CITY APPROVED LOCATIONS.
FILE NAME:
AIR RELEASE VALVE ASSEMBLY
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 21
NOTE:
VENTED ENCLOSURE TO BE COLOR CODED
AS FOLLOWS:
WATER MAIN - BLUE
FORCE MAIN - GREEN
REUSE MAIN - PURPLE
FINISHED GRADE
CONCRETE SLAB AROUND ENCLOSURE
1-1/2" PIPE, PVC, LENGTH AS REQUIRED
4" & LARGER PIPE, D.I. OR PVC (DR-18)
2" DOUBLE STRAP TAPPING SADDLE, S.S.
2" PIPE, S.S. LENGTH AS REQUIRED
AIR RELEASE VALVE 2" NPT AS APPROVED
ENCLOSURE AS APPROVED
DESCRIPTION
M A T E R I A L S
1-1/2" x 90° ELBOW, PVC
2" CORPORATION BRASS
14 1
15 2
1" SHORT NIPPLE, S.S.
2" X 1" REDUCER, S.S.
2" TEE, S.S.
2" BALL VALVE, S.S.
2" x 4" NIPPLE, S.S.
1" CURB STOP, S.S.
2" SHORT NIPPLE, S.S.
2" x 90° ELBOW, S.S.
11 2
ITEM QUANT.
SEWER AIR RELEASE VALVES SHALL BE AS APPROVED
WATER AIR RELEASE VALVES SHALL BE AS APPROVED
#57 WHITE STONE
10 9
PAD SIZE 36"x36"
NOTE:
1. BUILT (ALL FITTINGS) OUT OF BRASS.
2. ONLY ALLOWED IN CITY APPROVED LOCATIONS.
LOCATOR WIRE
GATE VALVE
FILE NAME:
AIR RELEASE VALVE ASSEMBLY
ABOVE GROUND
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 22
#57 WHITE STONE
M A T E R I A L S
QUANT.
ITEM
DESCRIPTION
ACTIVATED CARBON
13 1
16 1
PLAN VIEW OF AIR VENT PIPES
ENCLOSURE AS APPROVED
AIR RELEASE VALVE 2" NPT AS APPROVED
1" CURB STOP, S.S.
2" x 4" NIPPLE, S.S.
2" BALL VALVE, S.S.
2" TEE, S.S.
2" X 1" REDUCER, S.S.
1" SHORT NIPPLE, S.S.
2" PIPE, S.S. LENGTH AS REQUIRED
2" DOUBLE STRAP TAPPING SADDLE, D.I.1
4" & LARGER PIPE, D.I. OR PVC (DR-18)
2" CORPORATION BRASS
1-1/2" PIPE, PVC, LENGTH AS REQUIRED
1-1/2" x 90° ELBOW, PVC
2" X 1-1/2" REDUCER, PVC
3" X 2" FLEX COUPLING
3" PIPE, PVC, LENGTH AS REQUIRED
3" x 90° ELBOW, PVC1
3" PIPE, PVC, LENGTH AS SHOWN,PERFORATED TOP HALF ONLY
3" TEE, PVC1
3" PIPE, PVC, LENGTH AS SHOWN,PERFORATED TOP HALF ONLY
10 3" CAP, PVC
PERFORATED
TOP HALF ONLY
24"
FINISHED GRADE
FILTER FABRIC
#57 WHITE STONE
23 1 CONCRETE SLAB AROUND ENCLOSURE
PAD SIZE 36"x36"
NOTE:
1. BUILT (ALL FITTINGS) OUT OF BRASS.
2. ONLY ALLOWED IN CITY APPROVED LOCATIONS.
FILE NAME:
AIR RELEASE VALVE ASSEMBLY
WITH ODOR CONTROL SYSTEM
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 23
FINISHED GRADE
M A T E R I A L S
QUANT.ITEM DESCRIPTION
ACTIVATED CARBON
10 9
13 1
2" x 90° ELBOW, S.S.
2" SHORT NIPPLE, S.S.
PLAN VIEW OF AIR VENT PIPES
ENCLOSURE AS APPROVED
AIR RELEASE VALVE 2" NPT AS APPROVED
1" CURB STOP, S.S.
2" x 4" NIPPLE, S.S.
2" BALL VALVE, S.S.
2" TEE, S.S.
2" X 1" REDUCER, S.S.
1" SHORT NIPPLE, S.S.
2" PIPE, S.S. LENGTH AS REQUIRED
2" DOUBLE STRAP TAPPING SADDLE, S.S.1
4" & LARGER PIPE, D.I. OR PVC (DR-18)
2" CORPORATION BRASS
1-1/2" PIPE, PVC, LENGTH AS REQUIRED
1-1/2" x 90° ELBOW, PVC
2" X 1-1/2" REDUCER, PVC
3" X 2" FLEX COUPLING
3" PIPE, PVC, LENGTH AS REQUIRED
3" x 90° ELBOW, PVC1
3" PIPE, PVC, LENGTH AS SHOWN,PERFORATED TOP HALF ONLY
3" TEE, PVC1
3" PIPE, PVC, LENGTH AS SHOWN,PERFORATED TOP HALF ONLY223
24 3" CAP, PVC
PERFORATED
TOP HALF ONLY
25 1 CONCRETE SLAB AROUND ENCLOSURE
FILTER FABRIC
FILTER FABRIC
#57 WHITE
STONE
PAD SIZE 36"x36"
NOTE:
1. BUILT (ALL FITTINGS) OUT OF BRASS.
2. ONLY ALLOWED IN CITY APPROVED
LOCATIONS.
LOCATOR WIRE
GATE VALVE
FILE NAME:
AIR RELEASE VALVE ASSEMBLY WITH ODOR
CONTROL SYSTEM AND COVER ABOVE
GROUND OFFSET PIPE LAYOUT
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
FIG. 24
WALL REINFORCEMENT
PER ASTM C-478
4000 PSI @ 28 DAY
CONCRETE, TYPE II CEMENT
TYPICAL BASE REINFORCEMENT
BARS @ 9" O.C. FOR GREATER DEPTHS.
FOR DEPTHS UNDER 6 FT., NO.4
SHALL BE NO.4 BARS @ 12" O.C.
PRIOR TO PAVING OF ROADWAY
PLACED AROUND MANHOLE FRAME
4'-0" MINIMUM INSIDE DIAMETER
PAVEMENT
BASE
12"
CONCRETE
RING
PAVEMENT
ADJUST TO FINISHED GRADE W/
1'-0"
L
C
BRICK AND
MORTAR INVERT
MANHOLE
( MAX. 12")
#57 AGGREGATE SHALL BE USED
UNDER WET CONDITIONS
FOR BEDDING OF STRUCTURE
AS DIRECTED BY CITY
8" MIN. WALL THICKNESS
(MINIMUM 9" WIDTH)
"EZ-WRAP" PLASTIC
EQUAL AT ALL JOINTS
12" RING OF CONCRETE TO BE
C.I. FRAME AND COVER TO
MEET MUNICIPAL STANDARDS
TOP OF BASE
C
AND COVER
C.I. FRAME
L
8" MINIMUM BASE THICKNESS
RUBBER BOOT CONNECTION
(SEE FIGURE 30)
MIN 21"
SEWER BRICK AND MORTAR.
MIN 1'
MINIMUM OF 1'
FROM TOP OF CONC TO
BASE FINISH GRADE.
NOTES:
INSTALL "WRAPID SEAL" OR
(HDPE ADJUSTING RING OR
PRE-FORMED CONC-RINGS
MAY BE SUBSTITUTED
FOR BRICK)
COAL TAR EPOXY COATING
OR
APPROVED EQUAL
INTERIOR: 16 MILS
(2 COATS)
EXTERIOR: 8 MILS
(1 COAT)
1. ON TRANSITIONS BETWEEN LARGER DIAMETER AND SMALLER
SEWER COLLECTORS, OR THE TOP OF THE INSIDE OF THE TWO
SEWER PIPES SHALL BE MATCHED.
2. NON-PENETRATING PICK-HOLES IN ALL CONCRETE SECTIONS.
3. USE FARBERTITE BITUMASTIC SEALER BETWEEN SECTIONS OF
MANHOLES.
4. 0.1' - DROP ACROSS MANHOLE TYP.
5. MAXIMUM DEPTH NOT TO EXCEED 15.0 FEET MEASURED FROM
MANHOLE TOP TO INSIDE BOTTOM.
6. ALL MANHOLES WHERE ANY INVERT INTO THE MANHOLE
EXCEEDS 18" SHALL REQUIRE A DROP CONNECTION.
7. RECEIVING, FORCEMAIN CONNECTED AND DROP MANHOLE
SHALL BE CONTINUOUSLY LINED WITH APPROVED EPOXY
LINER AT 90 TO 110 MIL THICKNESS OR APPROVED EQUAL.
8. RISER BETWEEN TOP CONE AND BOTTOM CASTING SHALL BE
NO SHORTER IN HEIGHT THAN 60". (MINIMUM DEPTH SHALL
NOT BE LESS THAN 60" AS MEASURED FROM MANHOLE TOP TO
INSIDE BOTTOM).
9. ADD BRICK AND MORTAR TO CREATE BENCH AND INVERT AND
BENCH NEEDS TO BE COATED WITH BITUMINOUS COATING.
10. INSTALL EZ-WRAP PLASTIC OR EQUAL AT ALL JOINTS (MINIMUM
9" WIDTH).
STANDARD MANHOLE
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 25
(SEE DETAIL S-13)
PRIOR TO PAVING OF ROADWAY
18" RING OF CONCRETE TO BE
PLACED AROUND MANHOLE FRAME
8" MIN. WALL THICKNESS
RUBBER BOOT CONNECTION
TO FILL OPENING CUT IN BASE.
8" MINIMUM BASE THICKNESS
FOR DEPTHS UNDER 6 FT.
SHALL BE NO.4 BARS @ 12" O.C.
TYPICAL BASE REINFORCEMENT
SECTION - SHALLOW MANHOLE
BRICK AND
MORTAR INVERT
5'-0" MIN. DIAMETER
C
L
L
C
TOP OF BASE
C.I. FRAME
AND COVER
8" MIN.
MANHOLE
# 57 AGGREGATE AS REQ,D.
PAVEMENT
MEET MUNICIPAL STANDARDS
C.I. FRAME AND COVER TO
CONCRETE
18"
RING
PAVEMENT
BASE
PER ASTM C-478
WALL REINFORCEMENT
4000 PSI @ 28 DAY
CONCRETE W/
TYPE II CEMENT
SEWER BRICK AND MORTAR.
ADJUST TO FINISHED GRADE W/
( MAX. 12")
FOR DOUBLE MANHOLE COVER
(HDPE ADJUSTING RINGS, OR
PRE-FORMED CONC-RINGS MAY
BE SUBSTITUTED FOR BRICK)
PRE-CAST COLLARS
ACCEPTABLE ALSO
COAL TAR EPOXY COATING
OR APPROVED EQUAL
INTERIOR: 16 MILS
(2 COATS)
EXTERIOR: 8 MILS
(1 COAT)
USE FOR MANHOLES OF
5'-0" OR LESS IN DEPTH
NOTES:
1. INSTALL EZ-WRAP PLASTIC OR EQUAL AT ALL JOINTS (MINIMUM 9" WIDTH).
2. NON-PENETRATING PICK-HOLES IN ALL CONCRETE SECTIONS.
3. USE FARBERTITE BITUMASTIC SEALER BETWEEN SECTIONS OF MANHOLE.
SHALLOW MANHOLE
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 26
PRECAST
MANHOLE
WALL
PVC OR DIP
COLLAR ENCASED IN
NON-SHRINK GROUT
FLUSH WITH MANHOLE
WALL (SEE NOTE 2)
BAND
STAINLESS STEEL
PVC OR
DIP
STAINLESS STEEL
PIPE CLAMP
RESILIENT
CONNECTOR
PRECAST
MANHOLE
WALL
SPECIAL DETAIL FOR 24" DIAMETER
PIPE AND LARGER
STANDARD PRECAST MANHOLE
PIPE CONNECTION
NOTES:
1. DROP PIPE AND FITTINGS SHALL BE OF EQUAL SIZE AND
MATERIAL AS THE INFLUENT SEWER.
2. THE CITY MAY APPROVE ALTERNATE WATERTIGHT
CONNECTION DETAILS FOR CONNECTION OF 24"
DIAMETER PIPES AND LARGER.
3. AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR
ALL INFLUENT WHICH HAVE AN INVERT 24" OR MORE
ABOVE THE OUTFLOW PIPE INVERT.
4. BOTTOM ELEVATION OF DROP CONNECTION SHALL BE 0.1
FT ABOVE EFFLUENT INVERT.
5. INSIDE DROP ONLY ALLOWED WHEN OUTSIDE DROP IS
NOT FEASIBLE AND APPROVED IN WRITING BY CITY.
BREAKOUT PIPE
FORMED CHANNEL
6" GRAVEL BASE
FOR SPECIAL CONDITIONS ONLY
6" MIN
POURED IN PLACE
3000 PSI CONC. FOR
CONC. BENCH TO
COVER 80% OF
PIPE DIAM.
GLUED JOINT
DROP CONNECTION M.H.
6" MIN.
GLUED JOINTS
VARIES
FLOW
RECONSTRUCT INVERTS AS REQ'D.
ONLY
PRIOR TO PAVING OF ROADWAY.
PLACED AROUND MANHOLE FRAME
12" RING OF CONCRETE TO BE
( I.E. RETROFIT CONSTRUCTION )
OPEN
FLOW
MANHOLE CONNECTION
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 27
PLUG
"A"
AS LATERAL
DROP CONNECTION
PIPE & FITTINGS TO
BE SAME MATERIAL
GLUE ALL JOINTS INTERNAL
CLAMPS TO BE
1 1/2" x 12"
1/2" STAINLESS
STEEL BOLTS.
STAINLESS STEEL,
ANCHORED TO M.H.
WALL WITH 2 1/2" x
( 2' ON CENTER )
AS CLOSE AS
POSSIBLE TO M.H.
WALL AND TO BE
SECURED TO THE
WALL WITH STAINLESS
PIPE TO BE PLACED
STEEL CLAMPS
S L O
P E
PLAN
RUBBER
BOOTS
REQUIRED
TEE
SECTION "A"-"A"
LAY PIPE TO
UNDISTURBED
ELBOW EMBEDDED IN CONC.
CONC. BENCH TO COVER
80% OF MAINLINE PIPE
DIAMETER
@ 45° W/SEWER FLOW
FILL EXCAVATED SPACE
OUTSIDE MANHOLE AND PIPE
WITH 3000 PSI CONCRETE
FOR A WIDTH OF 6" EACH
SIDE OF PIPE BUT NOT LESS
THAN A TOTAL MIN. WIDTH
SOIL
OF 22".
"A"
M I N
MATCH
OVERTS
5'-0" (MIN.)
S L O
P E
NOTES:
P.V.C. GRAVITY SEWER
SEE DETAIL ??
FOR ADDITIONAL
INFORMATION
TO MANHOLE AS REQUIRED
OPEN
PLASTIC SPACERS
MIDWAY BETWEEN
CLAMPS
1. ALL INSIDE PIPING TO BE P.V.C.
2. USE FARBERTITE BITUMASTIC SEALER BETWEEN MANHOLE SECTIONS.
3. PRE-FABRICATED INSIDE DROP ASSEMBLIES ARE ACCEPTABLE ALTERNATES,
(RELINER - DURAN OR ENGINEER APPROVED EQUAL ).
4. DROP PIPE AND FITTINGS SHALL BE OF EQUAL SIZE AND MATERIAL AS THE
INFLUENT SEWER.
5. THE CITY MAY APPROVE ALTERNATE WATERTIGHT CONNECTION DETAILS
FOR CONNECTION OF 24" DIAMETER PIPES AND LARGER.
6. AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR ALL INFLUENT
WHICH HAVE AN INVERT 24" OR MORE ABOVE THE OUTFLOW PIPE INVERT.
7. INSTALL EZ-WRAP PLASTIC OR EQUAL AT ALL JOINTS (MINIMUM 9" WIDTH).
INSPECTION REQUIRED
PRIOR TO BACK- FILLING
THE CORED HOLE SHALL
NOT BE AT MANHOLE JOINT
WRAP PIPE WITH VISQUEEN
FOR SPECIAL
CONDITIONS ONLY
WHEN APPROVED IN
WRITING BY CITY
INSIDE DROP MANHOLE
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 28
BREAKOUT PIPE
FORMED CHANNEL
6" GRAVEL BASE
FOR SPECIAL CONDITIONS ONLY
6" MIN
POURED IN PLACE
3000 PSI CONC. FOR
CONC. BENCH TO
COVER 80% OF
PIPE DIAM.
GLUED JOINT
DROP CONNECTION M.H.
6" MIN.
GLUED JOINTS
VARIES
FLOW
FLOW
RECONSTRUCT INVERTS AS REQ'D.
ONLY
PRIOR TO PAVING OF ROADWAY.
PLACED AROUND MANHOLE FRAME
12" RING OF CONCRETE TO BE
( I.E. RETROFIT CONSTRUCTION )
SEE FIGURE 27
FOR ADDITIONAL
INFORMATION
OPEN
OUTSIDE DROP MANHOLE
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 29
STAINLESS STEEL STRAP
INSTALLED) W/
COUPLING (FACTORY
RUBBER BOOT MANHOLE
MANHOLE WALL
MANHOLE INVERT
PIPE
PRE-PRIMED
JOINT SURFACE
COMPLETED
JOINT WITH
SQUEEZE OUT
INSIDE WALL
(9" MINIMUM WIDTH)
OR EQUAL AT ALL JOINTS
INSTALL EZ-WRAP PLASTIC
JOINT SURFACES
PRE-MOLDED PLASTIC
JOINT SEALER WITH
PROTECTIVE WRAPPER
(REMOVED)
OUTSIDE WALL
PRE-PRIMED
MANHOLE PIPE CONNECTION DETAIL
FOR NEW CONNECTIONS IN EXISTING MANHOLES
PRECAST JOINT
CONNECTION
NOTES:
RAM-NECK
1. ALL NEW CONNECTIONS TO EXISTING SANITARY SEWER
MANHOLES SHALL UTILIZE A CORING METHOD AND THE IN-FIELD
INSTALLATION OF A RUBBER BOOT INTO THE MANHOLE.
RUBBER BOOT AND PRECAST JOINT
CONNECTION
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 30
2 NON-PENETRATING
PICKHOLES
NOTES:
2- RING WT.: 85 LBS. APP
1- MATERIAL; ASTM-A48 CLASS 35B GRAY IRON
SANITARY SEWER
C
I
T
Y
O
F
C
AS
S
L
B
E
R
R
Y
25 1/2"
1 1/2"
3- COVER WT: 120 LBS. APP.
24"
4"
25 3/4"
29 1/2"
E
COVER AND GENERAL NOTES
USF 117 RING & BL COVER
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 31
VARIES (TYP)
WYE WITH
6" BRANCH
6" 45°
BEND
REMOVABLE
PLUG (TYP)
R W
L I N
E
SEWER MAIN
SIZE VARIES
SEWER MAIN
SPRING LINE
ROTATE
30° (TYP.)
(SEE NOTE 1)
SLOPE TO
TERMINAL DEPTH AT
1.0% MIN. (TYP)
R W
FINISHED GRADE
TERMINAL DEPTH
AS REQUIRED FOR
SERVICE (3' MIN.)
(TYP.)
DOUBLE
SERVICESERVICE
SINGLE
SERVICE CLEAN-OUT
(SEE NOTE 2)
SERVICE CLEAN-OUT
(SEE NOTE 2)
LINE
LOT
LINE
LOT
(SEE NOTE 2)
SERVICE CLEAN-OUT
R
N
E
BEND
6" 45°
5' MAX.
(TYP.)
SERVICE (3' MIN.)
AS REQUIRED FOR
TERMINAL DEPTH
6" PVC
6" PVC
6" BRANCH
WYE WITH
PERMANENT PLUG (TYP)
NOTES:
1. INVERT OF LATERAL SHALL NOT ENTER SEWER
MAIN BELOW SPRING LINE
2. SERVICE CLEAN-OUTS SHALL BE INSTALLED AT
TIME OF BUILDING CONSTRUCTION BY THE
CONTRACTOR.
3. CITY APPROVED ELECTRONIC LOCATING
DEVICE SHALL BE INSTALLED AT THE END OF
EACH SERVICE STUB-OUT. MARKED WITH
GREEN, PAINTED 2x4 AND CURB CUT.
4. ALL SERVICES SHALL BE 6"
5. ALL JOINTS TO BE RUBBER GASKET (NO GLUED
FITTINGS) TYPICAL.
M A
X
M
1/8 BEND 45°
1/8 BEND
M
IN
. 2
S L O
P E
DESIGN GRADE
90° SWEEP
GLUED CAP
6" SINGLE SERVICE - ELEVATION
PLAN
PROFILE
D E
P T
H
G
R E
A T
R
A
N
C
L
SEWER MAIN
SANITARY SEWER LATERAL
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 32
5' MIN
10' WIDE
CONCRETE
WET WELL
WATER METER/BACK FLOW
2 - 6' SWING GATE
M
I N
M
I N
5'
MIN.
CONTROL PANEL
(SEE DETAILS)
VALVE
VAULT
CHAIN LINK FENCE
LIMITS OF SITE TO BE
DEDICATED TO CITY OF CASSELBERRY
5' MIN.
5' (MIN.)
R/W
C/L PUBLIC R/W
W
4" THICK CRUSHED ROCK
RTU ANTENNA
5' SIDEWALK
TO WITHIN 3" OF FENCE
1" WATER SERVICE
HOSE BIBB
BACK OF CURB
STREET LIGHT
LANDSCAPED AREA (3' MIN)
5'
5'
4' MIN
PREVENTER
NOTES:
1. THIS DIMENSION SHALL BE A MINIMUM OF 15' OR SHALL BE EQUAL TO
THE DEPTH OF THE WET WELL.
2. DRIVEWAY AND APRON SHALL BE SIX (6) INCH THICK, 3000 P.S.I.
CONCRETE.
3. POWER TO THE PUMP STATION SHALL BE THROUGH UNDERGROUND
CONDUIT FROM SUPPLY SOURCE IN RIGHT OF WAY.
4. LANDSCAPING SHALL BE REQUIRED AROUND PERIMETER.
5. DEVELOPER SHALL INSTALL AN AUTOMATICALLY CONTROLLED
SPRINKLER SYSTEM FOR LANDSCAPING. RECLAIMED WATER SHALL BE
USED WHERE AVAILABLE.
6. ENGINEER SHALL PROVIDE A SCALED (1" = 20' MIN.) SITE SPECIFIC
DETAIL DRAWING.
1 1
PUMP STATION TYPICAL SITE PLAN
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
GENERAL
DETAIL NO.
FIG. 33
N.T.S.
ELEVATION
PIPE SIZES.
WET WELL.
K
D D
MIN. SOLID SIZE: _________ IN.; CURVE: ___________.
WET WELL AND VALVE VAULT COVERS SHALL BE ALUMINUM WITH 304 S.S.
THERE SHALL BE NO VALVES OR ELECTRICAL JUNCTION BOXES IN
AND SMALLER. CLEARANCES SHALL INCREASE AS REQUIRED FOR LARGER
SPINDLES WITH MINIMUM CLEARANCES AS SHOWN FOR 6" DIAMETER PIPE
VALVE VAULT SHALL BE SIZED TO PERMIT EASY REMOVAL OF CHECK VALVE
BASE AND FIRST RISER UNIT TO BE CAST MONOLITHIC.
FLEXIBLE COUPLING SHALL BE SLEEVE TYPE.
HZ.: ________; PHASE: __________; H.P.: __________;
PUMPS SHALL BE:
GENERAL NOTES:
PANEL
CONTROL
SWEEP ELBOWS
(2 EACH) (10' APART)
25 OHM MAX. GROUND RODS
ALL HARDWARE IN WET WELL AND VALVE BOX TO BE STAINLESS STEEL.
HARDWARE AND LOCK BRACKET. SIZE AS REQUIRED BY PUMP MANUFACTURER,
MM, SPEED: _________ RPM; DISCHARGE SIZE: ________ IN.; VOLTAGE: _________;
MANUFACTURER: FLYGT______; MODEL: ___________; IMP: ________; DIA: _______;
TO ACCOMMODATE FLOW METER OR
PER NOTE *4
VALVE BOX SHALL BE ENLARGED
6"H**6"
VALVE VAULT
M I N
DRAIN
3" G.I.
FLOOR
M I N
PLUG VALVE
2"
(TYP)
COUPLINGS
FLEXIBLE
N.T.S.
PLAN VIEW
2' MIN
STANDARD FLANGED TEE
PLUG VALVE W/ 3" CAM-LOCK
AND RECESSED HANDLE (SEE NOTE 8)
ALUMINUM ACCESS HATCH W/ LOCKSET
WITH STAINLESS STEEL
CAPPED NIPPLE AND VALVE
DISCONNECT
PIPE (SCH. 80)
3" GALVANIZED
100 AMP SERVICE
HOSE BIBB W/R.P.Z.
CONCRETE
ENCASED IN
ELEV. Y
M
I N
M
I N
ELEV. AT
CONST.
INCOMING
POWER
7"
M I N
ELEV. W
ELEV. V
ELEV. X
ELEV. U
4"
4"
2"
*4 - 6"
O.C.E.W.
H D
P E
LAG PUMP ON
LEAD PUMP ON
HIGH LEVEL ALARM
BOTH PUMPS OFF
F L
A N
G E
D
O
N L
Y
F A
C T
O R
Y
T
H R
E A
D E
D
12"MIN
7"
NOTE 8
10"
11.5"
6'-0"
NOTE 8
4.25"
6'-0"
6'-0"
DIM F
DIM K
ELEV. T
DIM J
DIM H
DIM G
DIM E
DIM C
DIM B
DIM D
PUMPING
STATIONS
DIM A
ELEV. Y
ELEV. Z
ELEV. X
ELEV. W
ELEV. V
ELEV. U
M I N
9"
MIN
TO EXTEND 7" INTO BASE
STAINLESS STEEL ANCHOR BOLTS
MIN. 3/4 DIA. x 11"
* PER PUMP MANUFACTURERS REQUIREMENT
DRAIN. SLOPE OUTLET
PVC PIPE 3" FLOOR
PIPE 1/2" PER FOOT WITH
CHECK VALVE W/LEVER OPERATOR
2 - * 4 BARS
PRESSURE GUAGE
PLUG VALVE
(RESTRAINED JOINT)
PET COCK VALVE
DUCTILE IRON PIPE
DIMENSIONS
3"
G
F
B
E E
D D
HATCH W/LOCKSET &
4" D.I. VENT WITH VENT CAP
CABLE HOLDER
ALUMINUM ACCESS
ACCESS OPENING
GROUT
ELEV. Z
45°
C
2" DIA. SCH. 40-304
FOR CLARITY
SHOWN ROTATED 90°
LIFTING CHAIN WITH 12" 316
STAINLESS STEEL PIPE
316 STAINLESS STEEL GRIP EYE
POWER CABLE
ELEV. T
LIQUID LEVEL
4-20MA O-10 PSI
12"
A
N.T.S.
3"
GRAVEL
*6 -12 O.C. E.W.
PUMP STATION DETAILS
PLANS, SECTION, AND NOTES
SECTION VIEW
TELEMETRY AND MONITORING SYSTEM
INSTALLATION DETAIL
WITH BYPASS
EXIST. GRADE
BACKFLOW PREVENTER
FLAP VALVE
SHALL BE EPOXY COATED
PUMP STATION CONTROL PANEL - RADIO
SERVICE ENTRANCE RISER
N.T.S.
METER BASE
CONTROL
PANEL
METER
FPL
SERVICE
DISCONNECT
WASTEWATER PUMP
TRANSDUCER
SERVICE POINT V, __ PH, 60 HZ.
TO POWER CO.
3" CONDUIT
ALARM
LIGHT
3/4" CONDUIT
COAX CABLE - 1/2" GRS.
SECURELY ATTACH TO
MAST AS REQUIRED
LIGHTNING PROTECTION
UNIT BY INSTR. SUPPLIER,
BOND TO GROUND GRID.
ROUTE TO RTU.
SUPPORT AS REQ.D
ANTENNA MOUNTING
HEIGHT TO BE
DETERMINED BY
INSTR. SUPPLIER
#2/0 AWG. BARE
COPPER, BOND TO
GROUND GRID
CONCRETE BASE
(CONFIRM BASE
MOUNTING DETAIL)
NOTE:
1. ALL HARDWARE SHALL BE
STAINLESS STEEL.
N.T.S.
MAST INSTALLATION
RTU ANTENNA &
6" THICK
CONCRETE PAD
CONC.
CONC.
CONC.
1-1/2" MIN MOUNTING STRUT
ROUTE TO
SEAL OFF
MOTOR CONDUCTOR
CONDUIT 2" SCH. 80
PVC (SEE NOTE 2)
CONTROL CONDUIT
2" SCH. 80 PVC
SECURE HOSE BIBB TO
ANTENNA
ALARM BELL/HORN
PIPE MOUNTED ALARM LIGHT
BEHIND PANEL
GALVANIZED PIPE WITH
STAINLESS STEEL CHAIN
OPERATING CONDITIONS:
WITH A MINIMUM SIZE OF 48 INCHES BY 48 INCHES INTERIOR DIMENSION.
POINT
D.O.C.
MAX.
GPM TDH (FEET)
0.0
100 YEAR FLOOD ELEVATION=
CHECK VALVE
16"
36"
48"
ROHN 25G COMMUNICATIONS
STRUCTURE ON TRIPOD BASE
MIN.
3-6
DIAMETER
(INCHES)
HEIGHT (FEET)
THICKNESS (INCHES)
WET WELL AND VALVE VAULT LINER
26-3521-257-12 13-20
6"
12"
4"
12"
12"
12"
12"
6"
12"
6"
RECESSED HANDLE
STAINLESS STEEL FLAPPER
2' MAX
12" MIN
WET WELL AND VALVE VAULT SHALL HAVE AN INTEGRAL INTERIOR LINER
AS SPECIFIED IN SECTION OF THE UTILITY STANDARDS MANUAL.
MATERIAL MANUFACTURER
EMERGENCY GENERATOR RECEPTACLE
SHALL BE CROUSE-HINDS
MODEL AR1047 100 AMP.
STAINLESS STEEL STRAPS
OUTLINE OF
ANTENNA
TRANSDUCERS
8"
6.
7.
9.
8.
1.
2.
3.
4.
5.
OIL-FILLED PRESSURE GAUGE
12"x12"x4" CONCRETE PAD
VALVE LID SHALL BE LABELED
"SEWER" AND SET IN
PLUG VALVE
180° FROM CONTROL PANEL
STAINLESS STEEL
PLUG VALVE
"SEWER" AND SET IN
VALVE LID SHALL BE LABELED
12"x12"x4" CONCRETE PAD
AND WALL OF WELL
4" MINIMUM BETWEEN 90° FLANGE
OUT CONNECTION
EMERGENCY PUMP
SEE NOTE 21
CORE & BOOT
12"
STAINLESS STEEL
U-CLAMP ANCHORED
TO WALL
(MJK OR EQUAL)
LIFT STATION NOTES:
1. TCU TELEMETRY MANUFACTURED BY DATA FLOW SYSTEMS, INC. SHALL BE
FURNISHED INCLUDING TRANSIENT FILTER SHIELD OR T.F.S.
2. GUIDE/LIFT RAILS SHALL BE 2" STAINLESS STEEL PIPE.
3. PUMPS SHALL BE FLYGT OR EQUIVALENT (TO BE APPROVED IN WRITING BY THE CITY
ENGINEER).
4. ALL EXPOSED METAL SHALL BE PRIMED WITH TWO (2) COATS OF EXTERIOR ENAMEL
PAINT.
5. WET WELL AND VALVE VAULT SHALL BE COATED WITH COAL . TAR INSIDE AND OUT
(TWO COATS ; 9 MILS EACH) EACH JOINT TO BE WRAPPED WITH WRAPID SEAL OR
EQUIVALENT.
6. VALVE VAULT SHALL HAVE SEALED FLOOR AND DRAIN.
7. ALL LOCATIONS WHERE PIPES ENTER OR LEAVE THE WET WELL OR VALVE VAULT.
SHALL BE MADE WEATHER TIGHT WITH ALL SLEEVES OR NON-SHRINK GROUT.
8. VALVE BOX SHALL BE MIN. 6'x6' SQUARE.
9. PANEL SHALL BE STAINLESS STEEL & MIN. SIZE OF 2' X 3'.
10. POTABLE WATER SUPPLY WITH HOSE BIB & REDUCED PRESSURE BACK FLOW
PREVENTER (TO BE FIELD LOCATED).
11. CHECK VALVES SHALL BE LEVER AND SPRING TYPE, WITH CONTROL VALVE ARMS
FACING CENTER OF VAULT, AS MANUFACTURED BY KENNEDY OR APPROVED EQUAL.
12. PLUG VALVE SHALL BE DEZURIK OR APPROVED EQUAL.
13. WET WELL & VALVE VAULT COVERS SHALL BE ALUMINUM WITH 316 STAINLESS STEEL
HARDWARE AND RECESSED LOCK BRACKET SIZED AS REQUIRED BY PUMP
MANUFACTURER.
14. FACE CONTROL PANEL AWAY FROM WET WELL OPENING.
15. CONDUIT TO WET WELL SHALL BE EXPLOSION PROOF SEALED.
16. ACCESS TO THE CONTROL PANEL, WET WELL, AND VALVE BOX SHALL BE PAD LOCKED.
17. REINFORCED PRE CAST WET WELL AND VALVE BOX.
18. CONCRETE STRUCTURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASTM C-913
& C-890, DESIGN FOR H-20 TRUCK LOADING.
19. ALL FASTENERS (NUTS AND BOLTS) IN WELL OR VALVE VAULT SHALL BE 316
STAINLESS STEEL.
20. AN RPZ BACK FLOW PREVENTER IS REQUIRED ON POTABLE WATER LINE.
21. PUMP OUT CONNECTION SHALL BE 12" FROM BOTTOM OF WET WELL & SHELL BE 4" FOR 6' DIM
WELLS & 6' FOR OVER 6' WELLS W/ SAME SIZE CAM-LOCKS.
EMERGENCY PUMP
OUT CONNECTION
SCH 80 PVC PIPE
EMERGENCY PUMP
CONNECTION
S U
B M
E R
S I B
P
U M
P
S
T A
T I O
N P
L A
N
S
E C
T I O
N
A
T
E S
C I T
Y
O
F
C
A S
S E
L B
E R
R Y
E N
G I N
E E
R I N
G
D
I V
I S
I O
N
I P
L E
T
L
A K
E
D
R V
I E
C A
S S
E L
B E
R R
Y
F
L
G E
N E
R A
L
D E
T A
F I G
D A
T E
2" SCH 80 PVC
2" SCH 80 PVC
M
I N
M
I N
SEE NOTE #4
SPD
A A
PANEL INSTALLATION NOTES:
1. PUMP MOTOR CONDUIT SHALL BE SIZE TO ACCOMMODATE 40% CONDUIT FILL. MINIMUM
CONDUIT SIZE TO BE 2" SCH 80 PVC.
2. POWER SUPPLY SHALL BE UNDERGROUND ON THE LIFT STATION SITE AND SHALL BE
3-PHASE, FROM A 3-PHASE SOURCE ONLY.
3. AN ELECTRICAL GROUNDING SYSTEM SHALL BE INSTALLED AS PER THE NATIONAL
ELECTRICAL CODE, LOCAL CODES AND ORDINANCES, AN UNDERGROUND PERIMETER
CABLE GROUNDING SYSTEM SHALL BE INSTALLED WITH CONNECTIONS TO AT LEAST
WET WELL COVER, VALVE VAULT COVER, CONTROL PANELS, GENERATOR, UTILITY
COMPANY TRANSFORMER, MANUAL DISCONNECT SWITCH, AND METAL FENCE. SEE
GROUNDING DETAILS.
4. THE STATION NAME, I.D. NUMBER, AND ADDRESS SHALL BE AFFIXED
TO THE FRONT OF THE METER CABINET.
5. ALL MOUNTING HARDWARE & BRACKETS AND ELECTRICAL ENCLOSURES SHALL BE 316
STAINLESS STEEL.
6. THE SCADA PANEL IS SHOWN FOR INFORMATION ONLY AND WILL BE INSTALLED IN THE
FUTURE (BY OTHERS).
CONTROL PANEL
SCADA PANEL (FUTURE)
3" 316 S.S. PIPE (SCH 40)
VIEW A-A
1-1/2" MIN. MOUNTING BRACKET
WITH PROTECTIVE CAP
RIGID ALUMINUM
ENCASED IN CONCRETE
(12 Ø TYP)
INCOMING POWER FROM UTILITY POINT
OF SERVICE (MINIMUM 2" SCH 80 PVC)
SWEEP ELBOWS (TYP)
MINIMUM 2" SCH 80 PVC
5 OHM MAX. GROUND RODS (10' APART)
CONTROL CONDUIT
2" SCH 80 PVC
MOTOR CONDUCTOR CONDUIT
2" SCH 80 PVC (SEE NOTE #1)
FROM CONTROL PANEL
SEAL OFF - TYPE ESYR
(TYP)
S.S. PIPE CAP
(TYP)
316 S.S. METER BASE
WITH BY-PASS
UTILITY POWER
DISCONNECT
UTILITY
DISCONNECT
METER
MAIN
BREAKER
SCADA PANEL (FUTURE)
3-1" SCH 80 PVC
TO ANTENNA POLE
FRONT VIEW
NTS
FINISHED GRADE
CONTROL PANEL
SPD
PUMP STATION CONTROL PANEL (480V)
FRONT & PLAN VIEW
CITY OF CASSELBERRY
ENGINEERING DIVISION
95 TRIPLET LAKE DRVIE
CASSELBERRY, FL 32707
FILE NAME:
GENERAL
FIG. 35
MCB MB1
MB2
MS1
MS2
OL
OL
3O
60Hz
PB
N
ECB
230V
GR
A
B
C
GENERATOR
RECEPTACLE
F6
F7
1A
1A
1A
F5
TERMINAL
STRIP
P2
P
U
C
DFS
STRIP
TERMINAL
P1
BATTERY
(BACKUP)
12VDC
MS1A
MS2A
LEAD
LAG
(4)
(2)
MS1 OL
MS2
C
C
OL
A1 A2
FL
A4
AB
ASB
(1)
TTS
ALARM
(3)
TTS
AL
A3
UNPROTECTED
321 4
10A
CB
DFS
PROTECTED
OUTPUT
INPUT
3 4
CCB 15A
F3 F1
1A
TERMINAL
STRIP
15A
TFS
DRB
GFDR
ALARM STRIP
3.5" MIN.
PUMP
SUBPANEL LAYOUT
GNDGND
TTS
C C
B
D R
B
MS1
TFS
12VDC
BATTERY
CTRL.
UNIT
MS2
MB1 MB2
ECB
NEUTRAL
GND
MECHANICALLY
INTERLOCKED
F2
BPR
WHITE
(7)
FR4
(8)
(5)
FR3
(6)
(3)
FR2
(4)
(1)
FR1
(2)
OFF
OUTER DOOR REMOVED TO SHOW DEADFRONT LAYOUT
GENERATOR RECEPTACLE
NEMA TYPE 3R S.S. ENCL. WITH CONTINUOUS HINGE
TRANSFORMER
THERMAL TERMINAL STRIP
TERMINAL BLOCK
RELAY
PUMP CONTROL UNIT
OVERLOAD
MOTOR STARTER
MAIN CIRCUIT BREAKER
MOTOR BREAKER
TYPICAL, ACTUAL LAYOUT MAY VARY WITH HORSEPOWER
FLOAT REGULATORFR
TTS
GFDR GROUND FAULT…