These are final construction documents for the Sherando Recreation Area Rehabilitation project located in the George Washington & Jefferson National Forest, administered by the USDA Forest Service Southern Region. The project, designed by ATRIAX, PLLC and prepared by Professional Engineer Harold J. Marvin (Virginia License 0413000750), includes architectural and engineering plans dated May 8, 2026, for a recreation area bathhouse facility.

The documents specify toilet room fixtures and accessories to be installed throughout the facility, with all items furnished and installed by the General Contractor (GC). Key fixtures include floor-mounted toilets (American Standard 2234.001), waterfree urinals with SloanTec glaze (Sloan Valve WES-1000-STG), shower systems (Symmons 3-325 and Watts HydroPanel II 450-e700), floor drains (Zurn Water Z415-BZ1), undermount lavatories (Durasein DLA104A), manual deck-mounted faucets (Chicago Faucets 802-V665ABCP), and flush valves rated at 1.6 gallons per flush (Sloan Valve Regal 111-1.6). The floor plan (Drawing A-101) depicts the layout of the bathhouse facility with designated areas for toilet rooms, change rooms, showers, and mechanical/electrical systems. A door and frame schedule provides specifications for all doors throughout the facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IN201 42

MENS TOILET /

CHANGE ROOM

WOMENS TOILET /

CHANGE ROOM

MECHANICAL

JAN

IN201 8

IN201 12

IN201 11

EXISTING BENCHES TO

BE PLACED BY NFS

EXISTING BENCHES TO

BE PLACED BY NFS

3 4

3 4

3 6

IN201

IN201

10 11

10 11 shelves

A-10

A-09 A-10

A-03 P-01

P-01

A-12

A-06 A-06

A-15

A-16

A-13

A-17 A-14

P-02

P-02

P-02

A-04

A-04 A-01

A-18

A-14A-17

A-15

A-17

A-17

A-07 P-14

P-01

P-01

P-01

P-01

P-01

P-01

P-01

A-16

A-14 A-14A-14 A-14

A-03

A-10

A-10

A-10

A-09

A-04

A-04 A-01

A-13

A-12

A-17

A-17

A-06

A-03

A-19 A-301

P-06

ELEC PANEL

4"VTR

A-17

A-17

A-16

A-16

A-16

A-16

A-16

A-06

P-03

P-03

P-05

P-05

P-04

P-04

P-04 P-04

P-04

P-04

P-04 P-04

P-04

P-04

P-04

A-08

A-08

A-07

CONC_4"

A-05

A-05

A-06

P-12

P-12

P-13

P-13

A-06

A-07

A-06

A-07

A-06

A-07

A-06 A-07

A-06 shelves

CO

PY

RI

GH

T

. A

TR

IA

X, P

LL

C.

A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DR

AW

IN

G

IS

T

HE

P

RO

PE

RT

Y

OF

A

TR

IA

X, P

LL

C.

A

NY

M

OD

IF

IC

AT

IO

N, D

UP

LIC

AT

IO

N

OR

U

SE

O F

TH

IS

D

RA

W

IN

G W

IT

HO

UT

T

HE

EX

PR

ES

S

W

RI

TT

EN

A

UT

HO

RI

ZA

TI

ON

O

F

AT

RI

AX

, P

LL

C.

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

DATE ARCHIVE NO.

DRAWING SHEET NO.DESIGNER

DRAWN

CHECKED

PROJECT NO. SHEET OF 85

DRAWING TITLE

GLENWOOD-PEDLAR

RANGER DISTRICT

PROJECT NAME

NO. REVISION / ISSUE DATE

SOUTHERN REGION

SHERANDO

RECREATION

AREA

REHABILITATION

GEORGE WASHINGTON &

JEFFERSON NATIONAL

FOREST

ATRIAX, PLLC

703 Main Ave SW, Hickory, NC 28602

828.315.9962

VIRGINIA LICENSE: 0413000750

6260275010602

FINAL CONSTRUCTION DOCUMENTS

5/08/2026

A-101

CCC BEACH PAVILION

BATHHOUSE 001 - FLOOR

PLAN

BB

HM

BB

5/08/2026

NORTH

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

1/4" = 1'-0"1 FLOOR PLAN

PROPOSED WORK KEYNOTES

1 PREPARE EXISTING CONCRETE FLOOR SLAB AS REQUIRED TO INSTALL

PROPOSED FLOOR TILE. INSTALL PROPOSED FLOOR TILE WITH SLOPE TO

EXISTING FLOOR DRAINS. REFERENCE FINISH SCHEDULE.

2 INSTALL PROPOSED PLUMBING PIPING AND CONNECT TO EXISTING WATER

SOURCE AND WATER HEATERS. REFERENCE PLUMBING DRAWINGS.

3 INSTALL PROPOSED WATERPROOFING MEMBRANE, AND WALL TILE TO ALL

INTERIOR WALLS TO BE FINISHED WITH WALL TILE. REFERENCE INTERIOR

ELEVATIONS.

4 INSTALL PROPOSED COUNTERTOPS AND TOILET ACCESSORIES INCLUDING, BUT

NOT LIMITED TO, MIRRORS, GRAB BARS, CHANGING TABLES, ELECTRIC HAND

DRYERS, TRASH RECEPTACLES AND TOILETS.

5 INSTALL PROPOSED PLUMBING FIXTURES. REFERENCE PLUMBING DRAWINGS.

6 INSTALL PROPOSED INTERIOR LIGHT FIXTURES. REFERENCE ELECTRICAL

DRAWINGS.

10 INSTALL PROPOSED GLASS PANES IN WINDOWS AS REQUIRED TO MATCH

EXISTING, CLEAR PANES IN UPPER HALF, FROSTED PANES IN LOWER HALF.

11 REPAIR, REFURBISH EXISTING WINDOW UNITS. PAINT TO MATCH ON EXTERIOR,

INTERIOR SIDE SEE ELEVATIONS.

# TOILET ROOM ACCESSORIES

Type Mark DESCRIPTION MANUFACTURER MODEL

FURNISHED

BY

INSTALLED

BY REMARKS

A-01 XLERATOR Hand Dryer Excel Dryer XL-SB-ECO GC GC All proposed toilet room accessories and fixtures are for basis of design.

Substitutions require Forest Service approval.

A-03 3-Roll Tissue Dispenser CTX Concrete Buildings RM54141 GC GC A-04 Metal Framed Mirror Bobrick B-165 GC GC A-05 Soap Dispenser - Surface Mounted Bobrick B-2111 GC GC A-06 Double Garment Hook Bobrick B-549 GC GC A-07 Folding Shower Seat Bobrick B-5181 GC GC A-08 Grab Bar Bobrick B-5806x24 GC GC A-09 Grab Bar Bobrick B-5806x36 GC GC A-10 Grab Bar Bobrick B-5806x42 GC GC A-12 Waste Receptacle - Surface Mounted Bobrick B-277 GC GC A-13 Baby Changing Station Bobrick KB110-SSWM GC GC A-14 Changing Cubicle Partition Scranton Products See Specifications 10 21 00 GC GC A-15 ABA Toilet Partition Scranton Products See Specifications 10 21 00 GC GC A-16 Toilet Partition Scranton Products See Specifications 10 21 00 GC GC A-17 Wall Mounted Privacy Screen with Headrail Scranton Products See Specifications 10 21 00 GC GC A-18 Surface Mounted Mop and Broom Holder Bobrick B-223 x 24 GC GC A-19 Wall Mounted Utility Shelves Uline H-5437 GC GC

TOILET ROOM FIXTURES

MARK DESCRIPTION MANUFACTURER MODEL

FURNISHED

BY

INSTALLED

BY REMARKS

P-01 Floor Mounted Toilet - Vitreous China American Standard 2234.001 GC GC P-02 Vitreous China Waterfree Urinal with SloanTec® Glaze. Sloan Valve WES-1000-STG GC GC P-03 Showeroff Shower system with metering valve Symmons 3-325 GC GC P-04 Floor Drain w/“Type B” Strainer Zurn Water, LLC Z415-BZ1 GC GC P-05 HydroPanel II shower system Watts HydroPanel II 450-e700 GC GC P-06 Mop Service Basin - Molded Stone Fiat Products MSBIDTG2424 GC GC P-12 Undermount Solid Surface Lavatory Durasein DLA104A GC GC P-13 Deck Mounted Manual Faucet with 4" centers Chicago Faucets 802-V665ABCP GC GC P-14 Wall Hung Janitors Sink TBD TBD GC GC P-15 Flush Valve - 1.6 gpf Sloan Valve Regal 111-1.6 GC GC

HAROLD J. MARVIN

Lic. No. 062813

RP OFESSIO AN L ENGI NEE

R

FW

LTH O VIRGINIA

EA

NOM

MOC

DOOR & FRAME SCHEDULE

DOOR

NO. ROOM NAME

DOOR FRAME

H

AR

D W

AR

E

SE

T

NOTESW

ID

TH

H

EI

G H

T

G

LA

ZI

N

G

PA

N

EL

M

AT

ER

IA

L

TH

IC

KN

ES

S

FR

AM

E M

AT

ER

IA

L

101 MENS TOILET /

CHANGE ROOM

3'-0" 6'-8" X WD 1 3/4"

102 WOMENS TOILET /

CHANGE ROOM

3'-0" 6'-8" X WD 1 3/4"

103 MENS TOILET /

CHANGE ROOM

3'-0" 6'-8" - WD 1 3/4" HM Louver in lower panel

104 WOMENS TOILET /

CHANGE ROOM

3'-0" 6'-8" - WD 1 3/4" HM

pwberes Pencil

File details come from the government source that posted it. Updated .