Building_135-Break_Room_101.pdf

PDF 1 MB Posted

Attached to
Watervliet Arsenal Pest & Vegetation Control Services
Solicitation number
W911PT26QA063
Issued by

About this file

This document is an architectural floor plan drawing for a repair facility deficiencies project at Watervliet Arsenal, New York. The drawing shows the overall ground floor plan for Building B135 (Project Number 91973) and is marked as "Ready to Advertise" with a status date of May 20, 2019. The plan was prepared by Burns & McDonnell Engineering Company, Inc., and is associated with U.S. Army Corps of Engineers, New York District, under Contract No. W912DS-18-D-0004.

The drawing depicts a 600 square foot renovation area encompassing multiple rooms including offices, restrooms, locker rooms, break rooms, storage, utility spaces, and corridors. The floor plan identifies 19 distinct rooms with specific designations (e.g., Room 112: Women, Room 113: Office, Room 115A: Women Locker). Key architectural notes specify contractor responsibilities for verifying dimensions, coordinating millwork and trim, providing fire-rated blocking for fixtures, ensuring ABA compliance for door clearances, and managing gypsum board installation and control joints. The plan references structural drawings, reflected ceiling plans, finish schedules, and life safety drawings for complete project specifications. An Engineering Change Notice (ECN 4) for South Office Renovation was approved on June 7, 2021, with an as-built drawing designation.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

PWR PWR

LOUVER

POW

ER36x12

PW

R24

PW

R24

PW

R24

PO

W

ER30

PW

R PW

R

PWR PWR

LOUVER

POW

ER36x12

PW

R24

PW

R24

PW

R24

PO

W

ER30

PW

R PW

R

UP

PWR PWR

LOUVER

POW

ER36x12

PW

R24

PW

R24

PW

R24

PO

W

ER30

PW

R PW

R

A-201 A1

A-201 F6

A-201 F1

A-201 C1

234567891011121314151617181920212223242526

273233

C

D

E

B

F

G

A1 A-101

A1 A-102

A1 A-103

A

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03 W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

W03

131 129

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04

W04 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1

101B 101A

100A 100

119 114 113

118A118

110A

115115A117A

A1 A-311 A1

A-711

A1 A-712

A1 A-713

A4 A-713

EQUIPMENT SHOWN ON PLAN IS FOR COORDINATION OF WORK SHOWN ABOVE ON SHEET A-052

SEE STRUCT FOR CATWALK DETAILS AND LIMITS.

D1 A-401

AREA NOT IN SCOPE OF WORK

SCOPE OF WORK LEGEND

GENERAL FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,

AND ABBREVIATIONS REFER TO SHEET AG001.

REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS

ARE CONTINUOUS ACROSS ALL DOOR OPENINGS.

FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION

REFER TO PARTITION TYPES SHEET.

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS

AND SITE CONDITIONS BEFORE BEGINNING WORK AND

FABRICATION. THE ENGINEER SHALL BE NOTIFIED IN WRITING

IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES.

IN NO CASE SHALL DIMENSIONS BE SCALED OFF PLANS, SECTIONS,

OR DETAILS FROM THESE DRAWINGS.

FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE

OF GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE. VERIFY

THERE IS A PULL SIDE MINIMUM 18 INCHES CLEAR FROM DOOR

STRIKE TO INTERSECTING WALL FOR ABA COMPLIANCE. NOTIFY

CONTRACTING OFFICER FOR NON-COMPLIANCE BEFORE SETTING

DOOR FRAME AND WALL LOCATIONS.

CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK

TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET

LOCATIONS.

REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL

FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS

UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.

PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING

IN WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT,

FLOOR AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP

MOUNTING SUPPORTS.

REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD

CONTROL JOINTS.

REFERENCE STRUCTURAL DRAWINGS FOR ROUGH OPENING

DIMENSIONS IN CAST-IN-PLACE CONCRETE WALLS.

FOR CONTROL JOINT DETAILS, REFER TO SHEET A-511.

REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,

FINISH FACE OF METAL STUD WALL, AND FACE OF PRECAST CONCRETE

WALL PANEL, UNLESS NOTED OTHERWISE.

THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS

NOTED OTHERWISE.

PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,

REFERENCE REFLECTED CEILING PLANS.

REFERENCE FURNITURE PLANS FOR LOCATIONS OF WALL

ACCESSORIES AND VISUAL DISPLAY EQUIPMENT.

PROVIDE BLOCKING AS REQUIRED.

PATCH AND REPAIR ALL ADJACENT SURFACES FROM DEMOLITION, MATCH

EXISTING.

ALL LOCATIONS WERE EXISTING 2” END GRAIN WOOD BLOCK IS TO BE

REMOVED FOR NEW WORK, NEW INFILL BLOCK SHALL BE REPLACED WITH

BUILDING BASE STANDARD 2” WOOD FIBER BLOCK INFILL. INSTALL FIBER

BLOCK INFILL AS RECOMMENDED BY PER MANUFACTURERS STANDARD

INSTALLATION AND FINISHING. EXISTING WOOD BLOCK DEMOLISHED SHALL

BE DISPOSED OF AS REQUIRED.

D

ES

IG

N

ED

B

Y:

COPYRIGHT © 2019 BURNS & McDONNELL ENGINEERING COMPANY, INC.

D W

N B

Y:

C

KD

B

Y:

FI

LE

N

AM

E:

SI

ZE

PL

O T

SC

AL

E:

PL

O T

D

AT

E:

D

AT

E:

PR

O

JE

C

T N

O

C O

N

TR

AC

T

N O

W

2D

S-

-D -0

AF

D

R

AW

IN

G

C O

D E:

X2

A

NEKEY PLAN

SO

LI

C

IT

AT

IO

N N

O

US ARMY CORPS

OF ENGINEERS

New York District

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

Y O

R K

D

IS

TR

IC

T

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

W

AR

D P

AR

KW

AY

, K

AN

SA

S C

IT

Y, M O

1 753 92 864 10

A

B

C

D

E

F

G

W

AT

ER

VL

IE

T

AR

SE

N

AL

, N

EW

Y O

R K

R

EP

AI

R

F

AC

IL

IT

Y D

EF

IC

IE

N

C

IE

S (B

5)

PN

READY TO ADVERTISE

PR

J#

SE

S

SW

/1

5/

M

AY

0, 5/

/2

9:

:2

AM

As in di ca te d

A-010

O

VE

R

AL

L G

R O

U N

D F

LO

O

R P

LA

N

B.

BO

R

TZ

M .G

R U

H

AL

A B.

BO

R

TZ

8_ A_

C

EN

TR

AL

SCALE: 1/32" = 1'-0"A1 OVERALL GROUND FLOOR PLAN

16'0 32' 64'

N

GROUND FLOOR ROOM...

ROOM # ROOM NAME

112 WOMEN

113 OFFICE

114 OFFICE

115 WOMEN

115A WOMEN LOCKER

116 UTILITY

117 UTILITY

117A STAIRS

118 MEN

118A MEN LOCKER

119 ELECTRICAL

GROUND FLOOR ROOM...

ROOM # ROOM NAME

100 MEN

100A MEN LOCKER

101 BREAK ROOM

101A JANITOR CLOSET

101B WOMEN

104 UNASSIGNED

105 UNASSIGNED

106 UNASSIGNED

109 STORAGE

110 MEN

110A CORRIDOR

111 OFFICE

SY

M

D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

EA

D Y

TO

A

D

VE

R

TI

SE

/2 0/

BA

B

EC

N

SO

U

TH

O

FF

IC

E R

EN

O

VA

TI

O N

/0

7/

BA

B

AS

-B

U

IL

T D

R

AW

IN

G

1395362247.CIV

Rectangle

1395362247.CIV

Highlight

1395362247.CIV

Callout

600 SF (+/-)

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .