Brooklyn Equip. Inventory List.pdf
PDF 51 KB Posted
- Attached to
- J063--Fire Alarm Service and Upgrade
- Solicitation number
- 36C24226Q0336
About this file
This is an equipment inventory list for fire alarm systems at Brooklyn facilities. The document details the equipment and components subject to maintenance and repair services across multiple buildings.
Fire Alarm System - Building 1 contains an extensive array of fire detection and alarm equipment including two Notifier AFP 400 control panels, 289 addressable smoke detectors with bases, 81 heat detectors, 38 duct detectors, 151 manual stations, 394 speaker/strobes, 121 strobe lights, 76 door holding devices, 120 tamper switches, 97 water flow switches, 16 shunt trip relays, fire pump equipment (power, running, controller), generator equipment with engine running capability, air pressure switches, and associated networking and annunciation devices. All listed equipment includes service call coverage. Maintenance is performed on an "As Needed" basis for repairs.
Fire Alarm System - Building 15 contains 63 smoke detectors, 13 heat detectors, 3 fire pump monitors, plus additional relay equipment including 4 elevator recall relays, 15 waterflow switches, 15 strobes, 4 shunt trip relays, 8 fan shutdown relays, 3 smoke hatch relays, 2 damper relays, 9 smoke purge relays, and a sound and security relay. All equipment includes service call coverage with repairs performed as needed. Contractor responsibilities include inspection of smoke detectors (including duct detectors), electromechanical door holding devices, heat detectors, manual pull stations, audible and visual devices, control panel functions, elevator recall supervisory checks, and provision of all labor, parts, and equipment for emergency repair service.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24226Q0336 0002.docx | DOCX document | |
| Inspection Report Summaries.pdf | ||
| 36C24226Q0336 0001.docx | DOCX document | |
| 36C24226Q0336.docx | DOCX document | |
| Site Visit Info - Fire Alarm.pdf | ||
| Battery_Price_Schedule.pdf | ||
| NYH Battery Inventory.pdf | ||
| St Albans Equip. Inventory.pdf | ||
| Manhattan Equip. Inventory List.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment B – Brooklyn Equipment Inventory List
Equipment Shop Make Model Serial No.
Service calls included Y/N
PM
Frequency
Minimum Required Preventative Maintenance
Network notifier 2020 panel Y Two audio voice links Y
Fire Alarm system Bldg 1 Electrical
Two notifier AFP 400 panels Y
Repairs As Needed
The Contractor shall be responsible for repair of identified problematic component by VA staff, and programming updates of the fire alarm system. The Contractors are required to perform the repairs in accordance with local, state, and national, codes.
MAINTENANCE AND INSPECTION
SHALL CONSIST OF THE FOLLOWING:
INSPECTION OF SMOKE DETECTORS
(INCLUDING DUCT DETECTORS)
INSPECTION OF
ELECTROMECHANICAL DOOR
HOLDING DEVICES
INSPECTION OF HEAT DETECTORS
INSPECTION OF MANUAL PULL
Three intelligent network annunciators
Y
Two PRN-4 printers Y LCD terminal Y Three LCD-80 annunciators Y 289 Smoke detectors addressable with bases
Y
81 heat detectors addressable with bases
Y
38 duct detectors addressable Y 28 fan stop relays addressable Y 151 manual stations Y 76 door holding devices Y 120 tamper switches Y 97 water flow switches Y 394 speaker / strobes Y 121 strobe lights Y Notifier control panel Y Firestar hardwire fire control panel Y 16 Shunt trip relays Y Notifier 500 panel Y Notifier 200 panel Y Fire pump power Y Fire pump running Y Fire pump controller Y Generator engine running Y Air pressure switches Y Notifier fire alarm panel Y 6 door holder relays Y 38 manual stations Y 71 speakers / strobes Y 4 smoke vent relays Y 24 tamper switches Y 32 door holders Y 11 fire telephones Y 2 generator monitors Y 19 duct detectors Y
Fire Alarm system Bldg
Electrical
63 smoke detectors Y
Repairs As Needed
STATIONS
INSPECTION OF AUDIBLE AND VISUAL
DEVICES
TEST ALL CONTROL PANEL
FUNCTIONS AND THEIR OUTLYING
DEVICES (ANNUNCIATORS, PRINTER,
CRT, AVL AND BATTERY BACKUP,
ETC.)
ALL DEVICES SHALL BE CALIBRATED
AT LEAST ANNUALLY AS REQUIRED
FOR PROPER OPERATION.
ELEVATOR RECALL SUPERVISORY
CHECKS SHALL TEST ALL BLDG
ELEVATOR RECALLS AND ALL BLDG
AUDIO/VISUALS DEVICES.
CONTRACTOR SHALL PROVIDE ALL
LABOR, PARTS, AND EQUIPMENT FOR
EMERGENCY REPAIR SERVICE.
3 fire pump monitors Y 13 heat detectors Y
Transponder Y 4 elevators recall relays Y 15 waterflow switches Y 15 strobes Y 4 shunt trip relays Y 8 fan shutdown relays Y 3 smoke hatch relays Y 2 damper relays Y 9 smoke purge relays Y Sound and security relay Y