Bridge Inspection Report_3450-003P.pdf
PDF 2 MB Posted
- Attached to
- Rock Creek Park - Joyce Road Bridge
- Solicitation number
- 693C73-24-B-000010
About this file
This document is a Bridge Inspection Report for the Joyce Road Bridge over the Luzon Branch in Rock Creek Park, Washington, D.C. The report provides a detailed assessment of the condition of the concrete tee beam bridge, which is in poor condition and scheduled for replacement in the near future under Project PRA-ROCR 15(2). Key issues identified include widespread deterioration of the structural concrete, wearing surface deterioration, bearing device deterioration, scour at the south abutment, and erosion along the retaining wall. The report includes a load rating summary, structure inventory and appraisal data, condition assessments, recommendations, and cost estimates for maintenance, rehabilitation, and reconstruction. The total estimated reconstruction cost is $3,500,000.
The related federal contract opportunity is for the replacement of the Joyce Road Bridge under Solicitation Number 693C73-24-B-000010. The project consists of replacing the bridge, modifying existing walls, adding rip rap, and performing other miscellaneous work. The project is expected to cost between $2,000,000 and $5,000,000, and the bid documents are expected to be issued on or about May 1, 2024. The solicitation is restricted to certified Small Business Concerns only.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Results of Bid Opening - Project NP ROCR 15(2).pdf | ||
| FP14_Eng.pdf | ||
| ADV Bidders Qualifications Form.doc | DOC document | |
| Geotechnical Report.pdf | ||
| IFB Solicitation - NP ROCR 15(2).pdf | ||
| Plans - NP ROCR 15(2).pdf | ||
| Categorical Exclusion Form (NEPA).pdf | ||
| VETS-4212 Form.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
JOYCE ROAD BRIDGE AT MILITARY ROAD
JOYCE ROAD OVER LUZON BRANCH
ROCK CREEK PARK
LOOKING NORTH TOWARD 16TH STREET
STRUCTURE NO. 3450-003P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 7/13/2023
EAST (UPSTREAM) SIDE
Report prepared by:
Federal Highway Administration FLH Office of Bridges and Structures Bridge Inspection Program 22001 Loudoun County Parkway, Building E2, Suite 200 Ashburn, VA 20147 https://bridge.flhd.fhwa.dot.gov https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 3450-003P
JOYCE ROAD BRIDGE AT MILITARY ROAD INSPECTION DATE: 07/13/2023
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL:
MAIN SPAN TYPE:
# OF BEAMS, MAIN SPAN: .
DECK TYPE:
WEARING SURFACE:
ABUT. FOUNDATIONS:
PIER FOUDNATION(S):
ABUTMENT / PIER MAT'L: ..
PROJ./PLAN REF. NO:
NPS ROAD CLASS:
STRUCTURE HISTORY:
1 - CONCRETE
04 - TEE BEAM
1 - CONCRETE CAST-IN-PLACE
6 - BITUMINOUS
0 - UNKNOWN
6 - N/A
1 - CONCRETE
1 - PRINCIPAL PARK ROAD
NO. OF MAIN SPANS:
NO. OF APPR. SPANS:
STRUCT. TOTAL LENGTH: .
MAX. SPAN LENGTH:
DECK WIDTH:
CURB TO CURB WIDTH:
YEAR BUILT:
YEAR RECONSTRUCTED: .
SKEW ANGLE:
FRACTURE CRITICAL:
40.0 FT (12.2 M)
40 FT (12.2 M)
37.0 FT (11.3 M)
22.0 FT (6.7 M)
40 °
N
LOCATION
ROCK CREEK PARK
STATE: .............................. 113 - DISTRICT OF COLUMBIA
FACILITY CARRIED: ......... JOYCE ROAD
FEATURE INTERSECTED: LUZON BRANCH
MILE POINT: .. 0.35 (KM PT 0.56)
LOCATION: .... 0.3 MILES TO BEACH DRIVE.
INSPECTION TEAM: S. Hanny, O. Tariq
CONDITION ASSESSMENT:
Osama Tariq
REPORT REVIEW:
Marcus Miller
REPORT APPROVAL: Date: 01/12/2024
Jorgomai Ceesay
STRUCTURE EVALUATION SUMMARY
This concrete tee beam bridge is in poor condition and is scheduled for replacement in the near future under Project PRA-ROCR 15(2). The main problem is widespread deterioration of the structural concrete, as evident by the concrete core samples taken in March 2014. In addition, deterioration of the asphalt wearing surface (including cracking and holes up to 5" deep along the east gutterline) allows runoff to migrate under the pavement onto the concrete superstructure, thereby exacerbating the deterioration.
Additional problems include paint deterioration and rusting of the bearing devices, deterioration of the vertical joint filler material at both abutments, scour at the south abutment with the top of the footing exposed, and scour and erosion along the retaining wall.
It should also be noted that vagrant activity is evident under the structure. Inspectors and maintenance personnel should use caution when visiting the bridge.
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3450-003P
JOYCE ROAD BRIDGE AT MILITARY ROAD INSPECTION DATE : 07/13/2023
PRIORITY OF IMPROVEMENT226
A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
B
Item No.
Maintenance Recommendations
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT UNIT
COST
PRELIM.
COST
ESTIMATE
58.10,60.
6,61.4
REMOVE AND CUT BACK TREES AND VEGETATION
GROWTH AROUND STRUCTURE TO FACILITATE
INSPECTION.
1 LS 5000 5000
PRELIM. MAINTENANCE TOTAL : 5000
Item No.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST
PRELIM. COST ESTIMATES
REHAB RECONSTR
58,59,60 REPLACE STRUCTURE.
1 LS 3500000 3500000
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : 3500000
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL :
PRELIM. REHABILITATION TOTAL :
PRELIM. RECONSTRUCTION TOTAL : .. 3500000
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL * :
(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)
Remarks : Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 3450-003P
58. DECK
1. DECK SLAB
4. RIDEABILITY
5. CURBS, SIDEWALKS, AND MEDIAN
6. PARAPETS AND/OR RAILINGS
7. DRAINS AND DRAINAGE
8. UTILITIES
9. DEFLECTION AND/OR VIBRATION
10.OTHER:
59. SUPERSTRUCTURE
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10.ALIGNMENT
11.OTHER
60. SUBSTRUCTURE
61. CHANNEL
1. ALIGNMENT
2. EROSION AND/OR SCOUR
3. CHANNEL PROTECTION
4. WATERWAY OBSTRUCTIONS
5. OTHER
6. ADEQUACY OF OPENING
7. NORMAL VELOCITY
8. AVERAGE CLEAR OPENING
9. STREAMBED COMPOSITION:
222. APPROACHES
1. APPROACH SLABS
2. RELIEF JOINTS
3. APPROACH GUARDRAIL
4. SURFACING
5. EROSION
6. SETTLEMENT
7. SIGNS
8. ALIGNMENT
9. OTHER
223. RETAINING WALL
1. WALL
2. WEEP HOLES
3. FOUNDATION
4. EROSION AND/OR SCOUR
5. SETTLEMENT OR DEFLECTION
6. OTHER
P
G
F
F
P
G
F
P
P
N
N
N
F
N
N
G
G
N
F
G
G
F
N
1- SUFF
3 - LOW
N
N
N
F
F
P
G
N
G
G
F
F
G
F
N
2. EXPANSION JOINTS P
3. WEARING SURFACE F
N 9 FT
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLEN
EXCELLENT CONDITION9
VERY GOOD CONDITION - no problems noted.8
GOOD CONDITION - some minor problems.7
SATISFACTORY CONDITION - structural elements show some minor deterioration.6
FA R CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.4
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible. Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“ MM NENT” FA LURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability.
Structure is closed to
FA LED CONDITION - out of service; beyond corrective action. 0
SAND, ROCKVEGETATION
03 - CONCRETE FTG
ABUTMENTS
1. BREASTWALLS OR COLUMNS G
2. PILE BENTS N
3. CAPS AND/OR BEARING SEATS F
4. BACKWALLS AND/OR BULKHEADS F
5. FOUNDATIONS 03 - CONCRETE FTG F
6. WINGWALLS G
7. WEEP HOLES F
8. EXPANSION JOINTS P
9. EROSION AND/OR SCOUR F
10.SETTLEMENT OR DEFLECTION G
11.SLOPE PROTECTION N
12.OTHER N
36. TRAFFIC AND SAFETY FEATURES
A. BRIDGE RAILINGS:
B. TRANSITIONS:
C. APPROACH GUARDRAILS:
D. APPROACH GUARDRAIL ENDS:
N
N
PIER(S) TRAFFIC SAFETY RATING CODES
13. WALLS AND/OR COLUMNS N
N
N
N
N
N
N
0 - Does not meet standards or a safety features is 14.PILE BENTS required and none is provided.
15.CAPS AND/OR BEARING SEATS
1 - Meets currently acceptable standards.
16.FOUNDATIONS
17.EROSION AND/OR SCOUR N - Not applicable or a safety features is not required.
18.SETTLEMENT OR DEFLECTION
19.OTHER
FIELD INSPECTION REPORT STRUCTURE NO. 3450-003P
ITEM REFERENCE AND REMARKS
58.1 WIDESPREAD MODERATE LONGITUDINAL AND RANDOM CRACKING WITH HEAVY EFFLORESCENCE AND WATER LEAKAGE, AND SOME RUST STAINING AND EXPOSED REBAR ON DECK UNDERSIDE AND OVERHANGS, PRIMARILY BETWEEN BEAMS #2
THROUGH #6.
TWO DECK CORES TAKEN ON 3/11/2014, ABOVE BEAM #5 AT ABOUT 10' FROM NORTH END AND 7' FROM EAST CURB. CORE SAMPLES SHOW POOR CONCRETE COHESION AND WEAK BONDING TO ASPHALT PAVEMENT. MINOR UNDERMINING OF
ASPHALT PAVEMENT ALSO EVIDENT.
58.2 MINOR ACCUMULATION OF DEBRIS AND VEGETATION GROWTH IN EXPANSION JOINT; JOINT IS JAMMED WITH PACK RUST BETWEEN ARMOR ANGLES. MINOR RUSTING AND PITTING OF ARMOR ANGLES; MINOR SNOW PLOW DAMAGE. EVIDENCE OF
MOISTURE SEEPAGE THROUGH JOINT.
58.3
58.5
58.7
222.4
MINOR LONGITUDINAL AND MAP CRACKING OF ASPHALT WEARING SURFACE IN SOUTHBOUND LANE AND ALONG EAST EDGE.
MODERATE TO SEVERE SPALLING (UP TO 5"D) OF EAST GUTTER, PRIMARILY NEAR SOUTH END AND AT NORTH APPROACH;
DETERIORATION AND UNDERMINING OF WEARING SURFACE NEAR SOUTH END (EVIDENCE OF ADVANCED WATER LEAKAGE DAMAGE TO SUPERSTRUCTURE AT THIS LOCATION) AND OF APPROACH PAVEMENT AT NORTH EXPANSION JOINT. MINOR
CRACKING AND SPALLING OF APPROACH CURBS.
MODERATE ACCUMULATION OF DEBRIS WITH VEGETATION GROWTH IN BOTH CURBLINES.
58.6 MINOR DETERIORATION OF GROUT PADS UNDER RAIL POSTS; NO NEOPRENE PADS PRESENT UNDER RAIL POST BASE PLATES.
MINOR RUSTING OF WASHERS AT ANCHOR BOLTS. TOP RAIL LOOSE ON WEST RAILING AT RAIL POSTS #2 AND #3 FROM NORTH
END.
MINOR VEGETATION ALONG NORTH END OF WEST RAILING; MODERATE AT EAST RAILING. TREE REMOVED AT EAST RAILING
OVER SOUTH ABUTMENT; STUMP REMAINS.
58.8 UTILITY PIPE OPEN IN CENTER OF SOUTH ABUTMENT BREASTWALL.
58.10 VEGETATION OVERHANGS BOTH SIDES OF STRUCTURE.
59.1 SEVERE DETERIORATION OF PAINT WITH MODERATE RUSTING AND MINOR SECTION LOSS ON BEARING DEVICES AT NORTH
ABUTMENT.
59.2 WIDESPREAD MINOR LONGITUDINAL CRACKING (UP TO 1/32"W) OF CONCRETE TEE BEAMS WITH EFFLORESCENCE; MODERATE TO SEVERE ON BEAMS #4, #5, AND #6. MINOR VERTICAL CRACKING OF BEAMS. MINOR SPALL ON BEAM #1 NEAR MIDSPAN.
MINOR SPALL WITH EXPOSED REBAR ON BOTTOM OF BEAM #6, NORTH END.
BEAMS ARE CLOSE TO OR TOUCHING BACKWALL AT NORTH ABUTMENT, LEAVING NO ROOM FOR EXPANSION; MINOR CRACKING WITH EFFLORESCENCE AND RUST STAINING, DELAMINATION, AND SPALLING OF BEAM ENDS.
59.6 MODERATE TO SEVERE CRACKING WITH EFFLORESCENCE AND RUST STAINING, DELAMINATION, AND SPALLING OF END
DIAPHRAGMS AT NORTH ABUTMENT, PRIMARILY BETWEEN BEAMS #2 THROUGH #6.
WIDESPREAD GRAFFITI ON SUPERSTRUCTURE AND SUBSTRUCTURE.
60.1 MINOR VERTICAL CRACKING (UP TO 1/32"W) OF ABUTMENT BREASTWALLS; EFFLORESCENCE AT SOUTH ABUTMENT.
60.3 HEAVY ACCUMULATION OF DEBRIS AND TRASH FROM VAGRANTS ON BEARING SEATS AT NORTH ABUTMENT. MODERATE EFFLORESCENCE ALONG HORIZONTAL CONSTRUCTION JOINT AT SOUTH ABUTMENT BETWEEN BACKWALL AND BREASTWALL.
60.4 MINOR SPALLING (10'L TOTAL X UP TO FULL WIDTH X 1"D) OF TOP OF NORTH ABUTMENT BACKWALL, SOME PARTIALLY PATCHED WITH ASPHALT WITH MINOR VEGETATION GROWTH. SPALL ALLOWS RUNOFF TO MIGRATE UNDER ASPHALT PAVEMENT.
MODERATE HORIZONTAL CRACKING WITH EFFLORESCENCE ON SOUTH ABUTMENT BACKWALL NEAR TOP BETWEEN BEAMS #2 THROUGH #6. MINOR VERTICAL CRACKING WITH EFFLORESCENCE ON SOUTH ABUTMENT BACKWALL, PRIMARILY EXTENDING
FROM BEAM BOTTOM FLANGES.
60.5 MINOR TO MODERATE SCALING (UP TO 2"D) OF SOUTH ABUTMENT FOOTING AND SOUTHEAST WINGWALL STEP FOOTING.
60.6 MINOR CRACKING OF WINGWALL MASONRY MORTAR JOINTS WITH EFFLORESCENCE. HEAVY VEGETATION GROWTH ON
NORTHEAST WINGWALL; MODERATE ON NORTHWEST.
60.7 ONLY ONE WEEP HOLE VISIBLE AT NORTH ABUTMENT; MINOR LOSS OF FILL.
60.8 MODERATE TO SEVERE DETERIORATION OF JOINT FILLER MATERIAL AT ALL VERTICAL EXPANSION JOINTS. VEGETATION
GROWTH IN VERTICAL JOINT BETWEEN NORTH ABUTMENT AND NORTHEAST WINGWALL.
60.9
61.1
90 DEGREE TURN IN DOWNSTREAM CHANNEL. CHANNEL DIRECTED AGAINST SOUTH ABUTMENT; MODERATE SCOUR WITH TOP OF FOOTING EXPOSED. SOUTHEAST WINGWALL FOOTING TOP FACE EXPOSED 10'L; STEP FOOTING EXPOSED FULL LENGTH UP
TO 2'H.
MINOR EROSION AT END OF NORTHEAST WINGWALL.
61.2 SEE BRIDGE FILE FOR SCOUR EVALUATION.
61.4 SEVERAL SMALL TREES GROWING IN CHANNEL ALONG BOTH WINGWALLS AT NORTH ABUTMENT.
222.4 MINOR TO MODERATE TRANSVERSE AND MAP CRACKING (UP TO 1/2"W) OF NORTH APPROACH PAVEMENT WITH VEGETATION GROWTH; ASPHALT PATCHING AT CENTERLINE ALONG EXPANSION JOINT. MINOR RANDOM CRACKING AND TRANSVERSE CRACK ON SOUTH APPROACH PAVEMENT OVER END OF STRUCTURE; MINOR DETERIORATION OF ASPHALT PATCH IN
SOUTHBOUND LANE.
222.5
222.6
NO SIDEWALKS AT APPROACHES. UP TO 7" DROP-OFF AT APPROACH SHOULDERS. RUNOFF FROM NORTHEAST SHOULDER GOES ONTO BRIDGE THROUGH OPEN JOINT IN CURB. MINOR EROSION (1-1/2'L X 1-1/2'W X 1'D) ON WEST SHOULDER OF SOUTH
APPROACH.
222.7 "WEIGHT LIMIT 15 TONS" SIGN ON EAST SIDE OF SOUTH APPROACH AND WEST SIDE OF NORTH APPROACH; NORTH SIGN CAN
BE ROCKED BY HAND.
11' - 3" VERTICAL CLEARANCE SIGN ON WEST SHOULDER AT NORTH APPROACH - THIS SIGN IS FOR A BRIDGE THAT IS SOUTH
OF NPS BRIDGE.
DC BRIDGE PLAQUE (STR. # 239) ON NORTHEAST WINGWALL.
222.8 STRUCTURE ON MODERATE HORIZONTAL CURVE.
223.1 MINOR EFFLORESCENCE ON RETAINING WALLS. TREES GROWING ALONG DOWNSTREAM RETAINING WALL.
223.3 MODERATE SCALING (UP TO 1/2"D) OF UPSTREAM RETAINING WALL STEP FOOTING.
223.4 MODERATE SCOUR ALONG RETAINING WALL WITH STEP FOOTINGS EXPOSED APPROXIMATELY 60'L X UP TO 18"H.
36.A
36.B
RAILING HEIGHT OF 3'-1" DOES NOT MEET AASHTO MINIMUM HEIGHT SPECIFICATION OF 3'-6" FOR PEDESTRIAN BARRIERS.
WEST RAILING NOT CONNECTED TO SOUTH APPROACH RAILING. NO APPROACH RAILING PRESENT AT NORTH APPROACH OR
AT SOUTH APPROACH, EAST SIDE.
STRUCTURE LOAD RATING STRUCTURE NO. 3450-003P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 10 9 17 15
HS 13 12 22 20
TYPE 3 12 11 20 18
TYPE 3S2 19 17 31 28
TYPE 3-3 22 20 37 34
DESIGN LOADING: 2 - H 15
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
X ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 11/30/2015
LOAD RATING CONTROLLED BY: SHEAR
REMARKS: BRIDGE IS CURRENTLY POSTED FOR 15 TONS. SEE BRIDGE FILE FOR LOAD RATING CALCULATIONS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3450-003P
JOYCE ROAD BR DGE AT MILITARY ROAD INSPECTION DATE: 07/13/2023
STRUCTURE IDENTIFICATION
(201) PARK: ROCK CREEK PARK
(202) STRUCTURE NAME:..............JOYCE ROAD BRIDGE AT MILITARY
ROAD
(203) STRUCTURE KIND:............... 1 - BRIDGE
(204) STRUCTURE NUMBER:.........3450-003 P
2 - NATIONAL CAPITAL(205) NPS REGION:
(206) ROUTE CODE NUMBER:
(207) ROAD SECTION NO:............. 003P
(208) NPS ROAD CLASS:............... 1 - PRINCIPAL PARK ROAD
(209) WITHIN NPS BNDRY?:.......... Yes
(210) OPERATING UNIT:.................PARK
(211) PROJECT NO(S):
(212) DRAWING NUMBERS:...........NONE
(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE
(22) OWNER:................................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY / PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR:
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORIC DESIGNATION:
113 - DISTRICT OF COLUMBIA
11001 DISTRICT OF COLUMBIA
00000
1 6 4 00015 0
LUZON BRANCH
JOYCE ROAD
3450003P0000000
0 3 MILES TO BEACH DRIVE.
99.99 FT ( 99.99 M)
0 35 (KM PT: 0.56 )
3 - ON FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL:..........1 - CONCRETE (44A) APPR. STR. MATERIAL:............ 0 - Other
(43B) MAIN STR. TYPE:.................. 04 - TEE BEAM (44B) APPR. STR. TYPE:.................... 00 - OTHER
(45) NO. OF MAIN SPANS:..............001 (46) NO OF APPROACH SPANS:
(48) MAX. SPAN LENGTH:..............40 FT ( 12.2 M)
(49) STRUCTURE LENGTH:........... 40.0 FT ( 12.2 M) (108) WEAR SURFACE/PROTECT SYSTEM:
(216A) ABUTMENT #1 FDN:........... 0 - UNKNOWN A) TYPE WEARING SURFACE:.. 6 - BITUMINOUS
(216B) ABUTMENT #2 FDN:........... 0 - UNKNOWN B) TYPE MEMBRANE:................. 0 - NONE
(217A) PREDOM. PIER FDN:.......... 6 - N/A C) TYPE PROTECTION:.............. 0 - NONE
(217B) SECOND. PIER FDN:.......... 6 - N/A (218) IS SALT USED?.......................... YES
(107) DECK TYPE:.......................... 1 - CONCRETE CAST-IN-PLACE
LOAD RATING AND POSTING
(31) DESIGN LOAD:.........................2 - H 15 (41) LOAD RESTRICTION:.................. P - POSTED FOR LOAD
(66) INVENTORY RATING:..............13 TONS ( 11.8 METRIC TONS) (70) BRIDGE POSTING:...................... 2 - 20.0-29.9% BELOW LEGAL LOADS
(3-5 TONS)
(64) OPERATING RATING:..............22 TONS ( 20 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 07/13/2023 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N
(220) SPECIAL STUDY TYPE: 0 - NONE INSP. EVERY MONTHS - LAST INSP:
(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N
INSP. EVERY MONTHS - LAST INSP:
(C) SPECIAL INSPECTION:........ N
INSP. EVERY MONTHS - LAST INSP:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3450-003P
JOYCE ROAD BR DGE AT MILITARY ROAD INSPECTION DATE: 07/13/2023
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE:................................ 38° 57'48.19" N (51) CURB TO CURB WIDTH:............ 22.0 FT ( 6.7 M)
(17) LONGITUDE:............................ 77°02 '19 93" W (52) DECK WIDTH:.......................... 37.0 FT ( 11.3 M)
(19) DETOUR LENGTH:.................. 1 MI ( 2 KM) (32) APPR. ROADWAY WIDTH:...... 22.0 FT ( 6.7 M)
(28A) LANES ON STRUCT:.............02 (213) APPR. PAVEMENT WIDTH:... 22.0 FT ( 6.7 M)
(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 0 0 FT ( 0 M)
(42A) SERVICE ON:.........................5 - HIGHWAY-PEDESTRIAN RIGHT SHOULDER:.......... 0 0 FT ( 0 M)
(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN
(29) AVG DAILY TRAFFIC:..............2100 (34) SKEW ANGLE:......................... 40 °
(30) YEAR OF ADT:......................... 2019 (35) STRUCTURE FLARED:............ 0 - NO FLARE
(114) FUTURE ADT:.........................2310 (47) TOTAL HORIZ. CLEARANCE:.. 22.0 FT ( 6.7 M)
(115) YEAR OF FUTURE ADT:........2039 (50) SIDEWALKS
(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 6 0 FT ( 1.8 M)
(38) NAVIGATION CONTROL:.........0 RIGHT:.................................. 6 0 FT ( 1.8 M)
(39) VERTICAL CLEARANCE:.........0 FT ( 0 M) (214) BRIDGE RAIL TYPE
(40) HORIZ. CLEARANCE:..............0 FT ( 0 M) RAIL CONFIGURATION:...... 1 - FULL HEIGHT (NO PARAPET)
(111) ABUT OR PIER PROT:........... MATERIAL:........................... 6 - ALUMINUM
LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 1 - CONTINUOUS RAIL
(55) RIGHT:...............................00 FT ( 0 M) (215) BRIDGE RAIL HEIGHT:.......... 3 91 FT ( 1.19 M)
(56) LEFT:................................ 0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)
(54) MIN. VRT. UNDRCLRANCE:... .00 FT ( 0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:....................................... 4 (67) STRUCTURAL EVALUATION:
(59) SUPERSTRUCTURE:...............4 (68) DECK GEOMETRY:
(60) SUBSTRUCTURE:.......... 6 (69) UNDERCLEARANCES:................ N
(61) CHANNEL:................................6 (71) WATERWAY ADEQUACY:
(62) CULVERT:.................................N (72) APPROACH ALIGNMENT:
(222) APPROACHES:...................... 6 (113) SCOUR CRITICAL:.................... 5 - SCOUR WITHIN LIMITS OF
FOOTING OR PILES
(223) RETAINING WALL:.................6 (225) PURPOSE OF IMPROVEMENT: 3 - CONSTRUCTION
(36) TRAFFIC SAFETY FEAT: 0 0 N N (226) PRIORITY OF IMPROVEMENT: B - MAJOR
(75A) TYPE OF WORK:................... (227) MAINTENANCE COST:.............$ 5000
(75B) WORK DONE BY:.................. (228) REHAB / RECNSTR COST:..... $ 0
(76) IMPROVEMENT LENGTH:....... FT ( 0 M) (229) CONSTRUCTION COST:.......... $ 3500000
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIGURATION INFORMATION:
https://57'48.19
Inspector: Osama Tariq Structure Number: 3450003P0000000
Inspection Date: 07/13/2023 Facility Carried: JOYCE ROAD
Bridge Inspection Report
Pictures
PHOTO 3
Description LOOKING SOUTH TOWARD MILITARY ROAD
PHOTO 4
Description WEST (DOWNSTREAM) SIDE
Bridge Inspection Report
Pictures
PHOTO 5
Description GENERAL TOPSIDE VIEW LOOKING NORTH
PHOTO 6
Description DETERIORATION OF EXPANSION JOINT AT NORTH END OF STRUCTURE; ALSO NOTE
SPALLING OF TOP OF ABUTMENT BACKWALL
Bridge Inspection Report
Pictures
PHOTO 7
Description TYPICAL DETERIORATION OF EXPANSION JOINT AT NORTH END OF STRUCTURE;
SOUTHBOUND LANE SHOWN; ALSO NOTE TYPICAL SPALLING OF TOP OF ABUTMENT
BACKWALL
PHOTO 8
Description TYPICAL SPALLING OF EAST GUTTER; GUTTER NEAR SOUTH END OF STRUCTURE
SHOWN; NOTE DETERIORATION AND UNDERMINING OF WEARING SURFACE
Bridge Inspection Report
Pictures
PHOTO 9
Description TYPICAL SPALLING OF EAST GUTTER; GUTTER AT NORTH APPROACH SHOWN; NOTE
DETERIORATION AND UNDERMINING OF APPROACH PAVEMENT AT EXPANSION JOINT
PHOTO 10
Description TYPICAL DETERIORATION OF GROUT PADS UNDER RAIL POSTS; RAIL POST #4 FROM
NORTH ABUTMENT ON EAST RAILING SHOWN
Bridge Inspection Report
Pictures
PHOTO 11
Description VEGETATION GROWTH AT SOUTH END OF EAST RAILING
PHOTO 12
Description TYPICAL CRACKING OF NORTH APPROACH PAVEMENT WITH VEGETATION GROWTH; 20'
FROM STRUCTURE SHOWN
Bridge Inspection Report
Pictures
PHOTO 13
Description TYPICAL DROP-OFF FROM SIDEWALKS AT APPROACH SHOULDERS; EAST SHOULDER AT
NORTH APPROACH SHOWN
PHOTO 14
Description EROSION ON WEST SHOULDER AT SOUTH APPROACH
Bridge Inspection Report
Pictures
PHOTO 15
Description GENERAL VIEW OF LOAD POSTING, NORTH APPROACH; NOTE SIGN CAN BE ROCKED BY
HAND
PHOTO 16
Description VERTICAL CLEARANCE SIGN ON WEST SHOULDER AT NORTH APPROACH FOR BRIDGE
SOUTH OF NPS BRIDGE
Bridge Inspection Report
Pictures
PHOTO 17
Description GENERAL UNDERSIDE VIEW LOOKING SOUTH
PHOTO 18
Description TYPICAL CRACKING WITH EFFLORESCENCE AND LEAKAGE ON DECK UNDERSIDE; DECK
BETWEEN BEAMS #5 AND #6 AT NORTH ABUTMENT SHOWN
Bridge Inspection Report
Pictures
PHOTO 19
Description TYPICAL EXPOSED REBAR ON DECK UNDERSIDE; DECK BETWEEN BEAMS #6 AND #7 AT
SOUTH ABUTMENT SHOWN
PHOTO 20
Description TYPICAL DETERIORATION OF PAINT WITH RUSTING AND SECTION LOSS ON BEARING
DEVICES AT NORTH ABUTMENT; BEAM #2 SHOWN
Bridge Inspection Report
Pictures
PHOTO 21
Description TYPICAL LONGITUDINAL CRACKING OF BEAMS WITH EFFLORESCENCE; BEAM #5 NEAR
NORTH ABUTMENT SHOWN
PHOTO 22
Description TYPICAL DETERIORATION OF BEAM ENDS AT NORTH ABUTMENT; BEAM #5 SHOWN
Bridge Inspection Report
Pictures
PHOTO 23
Description TYPICAL DETERIORATION OF END DIAPHRAGMS AT NORTH ABUTMENT; DIAPHRAGM
BETWEEN BEAMS #4 AND #5 SHOWN
PHOTO 24
Description GENERAL VIEW OF NORTH ABUTMENT; NOTE TYPICAL GRAFFITI ON SUPERSTRUCTURE
AND SUBSTRUCTURE
Bridge Inspection Report
Pictures
PHOTO 25
Description TYPICAL VERTICAL CRACKING OF ABUTMENT BREASTWALLS; NORTH ABUTMENT
SHOWN
PHOTO 26
Description TYPICAL ACCUMULATION OF DEBRIS ON NORTH ABUTMENT BEARING SEATS; SEAT
BETWEEN BEAMS #2 AND #3 SHOWN
Bridge Inspection Report
Pictures
PHOTO 27
Description EFFLORESCENCE ALONG HORIZONTAL CONSTRUCTION JOINT AT SOUTH ABUTMENT
BETWEEN BACKWALL AND BREASTWALL
PHOTO 28
Description TYPICAL HORIZONTAL CRACKING WITH EFFLORESCENCE ON SOUTH ABUTMENT
BACKWALL NEAR TOP BETWEEN BEAMS #2 THROUGH #6; BACKWALL BETWEEN BEAMS
#5 AND #6 SHOWN
Bridge Inspection Report
Pictures
PHOTO 29
Description TYPICAL DETERIORATION OF JOINT FILLER MATERIAL AT VERTICAL EXPANSION JOINTS;
NORTHWEST WINGWALL SHOWN
PHOTO 30
Description SCOUR WITH EXPOSED SOUTH ABUTMENT FOOTING
Bridge Inspection Report
Pictures
PHOTO 31
Description EXPOSED SOUTHEAST WINGWALL AND RETAINING WALL STEP FOOTING; ALSO NOTE
SCALING OF STEP FOOTING
PHOTO 32
Description TREES GROWING ALONG DOWNSTREAM RETAINING WALL
Bridge Inspection Report
Pictures
PHOTO 33
Description UPSTREAM CHANNEL
PHOTO 34
Description DOWNSTREAM CHANNEL
File details come from the government source that posted it. Updated .