Big Sable Lighthouse Protection BID DOCS 21078_Part2.pdf

PDF 4 MB Posted

Attached to
751/21078. GAG; Ludington SP - Big Sable Point Lighthouse
Solicitation number
RFQ 171 220000000334 3
Issued by
Macomb County, Livonia City, Michigan

About this file

This is a bid document package for the Big Sable Lighthouse Protection project issued by the Michigan Department of Natural Resources at Ludington State Park in Ludington, Michigan. The project involves comprehensive coastal erosion protection and restoration work including replacement of 300 linear feet of sheet pile wall caps (with an additional 100 linear feet in Bid Addendum #1), placement of 270 cubic yards of proposed 2-foot thick MDOT heavy riprap in a swale configuration, delivery and placement of 300 tons (200 cubic yards) of supplemental 3-6 ton armor stone via marine transport, demolition of 6 linear feet of concrete wall, installation of three drainage systems, and related site restoration and protection measures. The project is located at Big Sable Lighthouse in Ludington State Park and includes protection of existing vegetation, keepers quarters, and associated structures. Construction staging will occur 350 feet south of the lighthouse utilizing an existing parking area near vault toilets on Lighthouse Road.

The bid documents establish specific technical requirements and contractor responsibilities including preparation and submission of construction sequencing and erosion and sediment control (SESC) plans prior to construction commencement, daily inspection and maintenance of all temporary SESC measures, daily sweeping and removal of sand tracked offsite, and compliance with state of Michigan regulations. The contractor is subject to a $500 per day fine and assessment of actual damage costs for failure to comply with the SESC plan. The owner will remove existing boardwalks as necessary, requiring contractors to provide 30 days' notice prior to construction staging. All SESC measures must be installed before construction begins, and temporary measures must remain in place until construction completion and approval for removal by the owner and engineer.

View the file

Other files

File Type Posted
Addendum 1 21078.pdf PDF
Big Sable Lighthouse Protection BID DOCS 21078_Part1.pdf PDF
Advertisment - Big Sable.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BEGIN 300 LF SHEET PILE

WALL CAP REPLACEMENT

(BID ADDENDUM #1)

END 300 LF SHEET PILE

WALL CAP REPLACEMENT

(BID ADDENDUM #1)

END 100 LF SHEET PILE

WALL CAP REPLACEMENT

2 OF 2BEGIN 100 LF SHEET PILE

WALL CAP REPLACEMENT

PROPOSED 2-FOOT THICK

MDOT HEAVY RIPRAP SWALE

270 CY

BEGIN PROPOSED

RIPRAP SWALE

END PROPOSED

RIPRAP SWALE

SEE SHEET C2.0

FOR DETAILS

PLACE 300 TONS / 200 CYD SUPPLEMENTAL 3-6 TON ARMOR STONE (48"

MAXIMUM SIZE) DELIVERED AND PLACED VIA MARINE TRANSPORT AND

CONSTRUCTION METHOD

EXISTING ARMOR STONE AND CONCRETE DEBRIS

BENEATH PROPOSED SUPPLEMENTAL STONE

EXISTING BIG SABLE

LIGHTHOUSE

10' 10'

EX LOOKOUT TOWER

SF

SF

PROTECT EXISTING

VEGETATION (TYP)

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

PLACE SILT OR SNOW FENCE

AROUND EXISTING VEGETATION FOR

PROTECTION (TYP)

SF

SF

SF

SFSF

SF

SF

SF

LOD

LOD LOD

LODLODLOD

LOD

PROTECT EX. TREE

EX KEEPERS

QUARTERS585

590590

59559

60560

OWNER WILL REMOVE EXISTING

BOARDWALKS AS NECESSARY FOR

CONSTRUCTION - CONTRACTOR

SHALL PROVIDE 30 DAYS NOTICE

PRIOR TO CONSTRUCTION

STAGING AREA

350' SOUTH

SCALE:

40 80

1" = 40'

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Project Layout.dwg - 3/15/2022

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

SOURCE:

1. Drone Survey-Horz. Datum State Plane NAD88 I.F.

Vert Datum NAVD88

OVERVIEW, PLAN, AND

SESC CONTROLS

C1.0

PLACE SNOW FENCE AS SAFETY

BARRIER TO SITE ACCESS FROM THE

NORTH

PRIOR TO BEGINNING CONSTRUCTION, PLACE

SNOW FENCE AROUND PERIMETER OF SITE.

MAINTAIN FENCE DURING CONSTRUCTION.

REMOVE FENCE AFTER CONSTRUCTION AND

RESTORATION IS COMPLETE

SESC NOTES:

1. SILT AND SNOW FENCE: INSPECT AFTER

RAINFALL & REMOVE ALL SEDIMENT WHEN IT

REACHES 50% OF CAPACITY.

2. CONTRACTOR RESPONSIBLE FOR ALL SESC

MAINTENANCE.

3. CONTRACTOR SHALL PREPARE AND SUBMIT

CONSTRUCTION SEQUENCE AND SESC PLAN

BEFORE CONSTRUCTION BEGINS.

4. CONTRACTOR IS RESPONSIBLE FOR $500 PER

DAY FINE AND ASSESMENT OF ACTUAL DAMAGE

COSTS ARISING FROM FAILURE TO COMPLY

WITH SESC PLAN AND STATE OF MICHIGAN

REGULATIONS.

5. CONTRACTOR SHALL INSTALL ALL SESC

MEASURES PRIOR TO BEGINNING

CONSTRUCTION. ALL TEMPORARY SESC

MEASURES SHALL BE INSPECTED DAILY AND

MAINTAINED BY THE CONTRACTOR.

TEMPORARY SESC MEASURES SHALL REMAIN IN

PLACE UNTIL CONSTRUCTION IS COMPLETE AND

APPROVED FOR REMOVAL BY

OWNER/ENGINEER.

6. CONTRACTOR SHALL SWEEP AND REMOVE

SAND TRACKED OFFSITE AS NECESSARY.

7. CONTRACTOR SHALL UTILIZE EXISTING PARKING

AREA NEAR VAULT TOILETS ON LIGHTHOUSE

ROAD APPROX. 350 FT SOUTH OF LIGHTHOUSE

FOR STAGING.

SITE FEATURES LEGEND:

LIMIT OF DISTURBANCE

SILT FENCE

RESTRICTED &

PROTECTED AREA

LOD

SF

1+00

0+00

585.23

584.75

585.17 584.91

584.64

584.28

584.62 584.45

585.37 584.97

585.15585.41

PROPOSED 2-FOOT THICK

MDOT HEAVY RIPRAP

(SEE RIPRAP SWALE SECTION

FOR FURTHER DETAILS)

EXISTING BACK OF

STEEL SHEET PILE

PROPOSED SUPPLEMENTAL

3-6 TON ARMOR STONE

(48" MAXIMUM SIZE)

EXISTING ARMOR STONE

BENEATH PROPOSED SUPPLEMENTAL STONE

PROPOSED RIPRAP

SWALE CENTERLINE 585

STA=0+25.65

STA=0+52.60

10' 10'

STA: 0+25.65

ELEV: 584.75

STA: 0+52.63

ELEV: 584.62

STA: 0+85.38

ELEV: 584.45

STA: 1+20.05

ELEV: 584.28 STA: 1+64.13

ELEV: 584.06

EXISTING GROUND AT

RIPRAP SWALE CENTERLINE

PROPOSED GRADE AT

RIPRAP SWALE CENTERLINE

0+00 0+25

4.

0+50

4.

0+75

4.

1+00

4.

1+25

4.

1+50

5.

0+00

5.

0+25

5.

0+50

5.

0+75

5.

1+00

5.

1+25

5.

1+50

0.5% 0.5% 0.5% 0.5%

SCALE:

10 20

1" = 10'

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Steel Pile - Plan&Profile.dwg - 10/20/2021

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

SOURCE:

1. Drone Survey-Horz. Datum State Plane NAD88 I.F.

Vert Datum NAVD88 C1.1

HORZ.

1" = 10' VERT.

M

AT

C H

L

IN

E 1+

PLAN & PROFILE

SHEET 1 OF 2

2+00

3+

3+

582.58

583.81

583.16

584.09

582.53

584.72

583.62

584.53

583.01

582.72

583.33

582.51

PROPOSED SUPPLEMENTAL

3-6 TON ARMOR STONE

(48" MAXIMUM SIZE)

EXISTING ARMOR STONE

BENEATH PROPOSED

SUPPLEMENTAL STONE

PROPOSED 2-FOOT THICK

MDOT HEAVY RIPRAP

(SEE RIPRAP SWALE SECTION

FOR FURTHER DETAILS)

EXISTING BACK OF

STEEL SHEET PILE

PROPOSED RIPRAP

SWALE CENTERLINE

DEMOLISH 6 LF OF CONC. WALL

CONSTRUCT PROPOSED RIPRAP SWALE

BETWEEN EXISTING WALL BREAK

(GRADE MAINTAIN POSITIVE DRAINAGE)

(SEE SHEET C.20 FOR DETAILS)

STA=2+52.98 STA=2+81.47

STA=2+90.92

STA=2+96.02

INSTALL (3) DRAINS EVERY OTHER

CORRUGATION PER DETAIL

SHEET C2, FIELD LOCATE AND COORDINATE

DRAIN INVERT ELEVATION WITH ENGINEER

10' 10'

10'

STA: 1+64.13

ELEV: 584.06

EXISTING GROUND AT

RIPRAP SWALE CENTERLINE

PROPOSED GRADE AT

RIPRAP SWALE CENTERLINE

STA: 2+08.20

ELEV: 583.62 STA: 2+52.98

ELEV: 582.72

STA: 2+81.47

ELEV: 582.58

STA: 2+90.92

ELEV: 582.53

STA: 2+96.02

ELEV: 582.51

4.

1+50

3.

1+75

3.

2+00

3.

2+25

2.

2+50

2.

2+75 3+00

5.

1+50

5.

1+75

5.

2+00

5.

2+25

2.

2+50

4.

2+75

2.

3+00

1.0% 2.0% 0.5% 0.5% 0.4%

(MATCH EX. GRADE)

EXISTING CONCRETE WALL

(DEPTH UNKNOWN)

SCALE:

10 20

1" = 10'

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Steel Pile - Plan&Profile.dwg - 10/20/2021

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

SOURCE:

1. Drone Survey-Horz. Datum State Plane NAD88 I.F.

Vert Datum NAVD88

PLAN & PROFILE

C1.2

HORZ.

1" = 10' VERT.

M

AT

C H

L

IN

E 1+

SHEET 2 OF 2

PROPOSED 2-FOOT THICK

MDOT HEAVY RIPRAP

EXISTING BACK OF

STEEL SHEET PILE

PROPOSED SUPPLEMENTAL

3-6 TON ARMOR STONE

(48" MAXIMUM SIZE)

PROPOSED BIG SABLE

LIGHTHOUSE BASELINE

EXISTING ARMOR STONE

BIG SABLE

LIGHTHOUSE

584 58

10'

PROPOSED SWALE

INVERT AND CENTERLINE

10'

EXISTING STEEL

SHEET PILE. REPLACE PILE CAP

(SEE LOCATIONS SHEET C1.0)

PROPOSED SUPPLEMENTAL

3-6 TON ARMOR STONE

1V:2H MAX SLOPE

DEPTH OF SHEET PILE

EMBEDMENT UNKNOWN

EXISTING ARMOR STONE

LAKE MICHIGAN

ELEVATION

581.06' (NAVD88)

9/31/21

PROPOSED 11OZ WOVEN

GEOTEXTILE FABRIC

PROPOSED 2-FOOT THICK MDOT HEAVY RIPRAP SWALE.

5.

10'

RIPRAP SWALE FLOWLINE

5'

TOP OF STONE SHALL BE FINAL PROPOSED GRADE. FILL STONE

VOIDS WITH SAND SPOILS. MATCH EXISTING GROUND. MAINTAIN

POSITIVE DRAINAGE TOWARDS SWALE OUTFALL

EXISTING GROUND AT

BIG SABLE LIGHTHOUSE BASELINE

EXISTING BIG SABLE

LIGHTHOUSE

10'

OHWM 580.50' IGLD85

(580.88' NAVD88)

5' TOTAL

DEPTH

-0+25 0+00

3.

0+25

5.

0+50

7.

0+75

7.

1+00

SCALE:

10 20

1" = 10'

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Section.dwg - 3/15/2022

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

SOURCE:

1. Drone Survey-Horz. Datum State Plane NAD88 I.F.

Vert Datum NAVD88

SECTION

C1.3

SCALE: 1" = 10' VERT.

HORZ.

10'

10'

EX. CONC.

WALLS/BARRIERS

DEPTH AND EXTENT

OF EX. CONC. BARRIER

WALL UNKNOWN

SAWCUT APPROX. 10' (5' EA

WALL) OF CONC. WALL . CRUSH

AND REPURPOSE AS ARMOR

STONE

PROPOSED RIPRAP

SWALE

EX. BEACH

EX. SHORELINE

EX. CONC. WALLS/BARRIERS

EX. NATURAL

GROUND

10'

DEPTH AND EXTENT OF EX.

CONC. BARRIER WALL

UNKNOWN

2' THICK HEAVY RIPRAP

OVER 11OZ WOVEN

GEOTEXTILE FABRIC

SAWCUT APPROX. 10' (5' EA

WALL) OF CONC. WALL . CRUSH

AND REPURPOSE AS ARMOR

STONE

C2.1

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Details.dwg - 3/15/2022

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

AS-BUILT FOUNDATION DETAIL

NOTE: EXISTING FOUNDATION IS BASED ON HISTORICAL RECORDS AND IS

INCLUDED FOR REFERENCE ONLY. CONTRACTOR TO FIELD VERIFY

LOCATIONS OF EXISTING STRUCTURE AND PROTECT DURING CONSTRUCTION.

EL=585' - EX. GROUND LEVEL

EL=587' - TOP OF EX. FOUNDATION

RIPRAP SWALE OUTLET - PLAN

NOT TO SCALE

RIPRAP SWALE OUTLET - SECTION

NOT TO SCALE

5" MAX (TYP)

FASTENER - MIN. NO. 10 GAGE WIRE

4 PER POST REQUIRED (TYP)

FILTER FABRIC

COMPACTED BACKFILL

UNDISTURBED GROUND LINE

FILTER FABRIC

18" MIN

(TYP)

2' MIN

6" MIN

6" MIN

FLOW

SILT FENCE DETAIL

SCALE: NTS

DETAILS

SHEET 1 OF 2

C2.2

\\lan-pzcc-1\ \\lan-pzcc-1\LAN-DATA\Projects\MDTMB\2101486 Big Sable and Little Sable Lighthouse Protection\00_CAD\Design\Sheets\BS_Details.dwg - 3/15/2022

BIG SABLE LIGHTHOUSE PROTECTION

LUDINGTON STATE PARK

LUDINGTON, MI

MICHIGAN DEPARTMENT OF

NATURAL RESOURCES 3/15/2022Project 2101486

Consultants

NO. DATE ISSUE/REVISION APP

1 10/29/2021 ISSUED FOR PERMIT CFG

2 4/20/2022 ISSUED FOR BID CFG

1/4"

TYP.

COMPACTED BACKFILL

STRUCTURAL

DETAILS

SHEET 2 OF 2

A C2.2

B C2.2

DRAIN - SECTION B

NOT TO SCALE

CAP PLATE CONNECTION - SECTION A

NOT TO SCALE

WATER SIDE

(ARMOR STONE

NOT SHOWN)

LOCATE CONNECTION

ANGLE OR PLATE EVERY 3RD

CORRUGATION OR LESSWIRE FABRIC, 1/8" S.S.

SHEET PILE WALL - PLAN VIEW

NOT TO SCALE

6" Ø

LAND SIDE

EXISTING STEEL SHEET PILE REPLACEMENT WALL CAP

CAP CHANNEL

EXISTING STEEL SHEET PILE

FIELD LOCATE AND COORDINATE

INVERT ELEVATION WITH ENGINEER

L2X2X1/4"

6" LENGTH

OR 2X1/4X6" ⅊

TYP.

GRADE

CAP CHANNEL

6" Ø

WIRE FABRIC, 1/8" S.S.

INSTALL DRAIN ONLY IN

LOCATIONS SHOWN ON

PLANS

INSTALL DRAIN ONLY IN

LOCATIONS SHOWN ON

PLANS

File details come from the government source that posted it. Updated .