Bid Sheet.xlsx
XLSX spreadsheet 13 KB Posted
- Solicitation number
- 23-9360 DIST
- Issued by
- Moffat County, Colorado
About this file
The document is a Bid Sheet for the Avondale Water and Sanitation District (AWSD) 2024 Distribution System Upgrades project located in Colorado. The project involves comprehensive infrastructure improvements, including the replacement of 22 gate valves (ranging from 1 to 6-inch sizes), 6 fire hydrants, and the installation of approximately 1,174 linear feet of new water mains (1,106 LF of 2-inch SDR21/HDPE and 68 LF of 4-inch C900 pipe). The work will be performed using open cut or boring methods, with associated paving, patching, and concrete work. The bid sheet itemizes 33 separate line items covering pipe installation, valve replacements, fire hydrant installations, asphalt and concrete work, traffic control, and miscellaneous site restoration activities.
The project addresses an aging water distribution system with components over 50 years old, focusing on critical infrastructure replacement. Specific technical requirements include using mechanical joint valves with Dresser fittings when connecting to AC pipe, and installing 5" American AVK Series 2780 fire hydrants in red, opening left. The bid sheet provides detailed quantities and unit pricing for each component, allowing for precise cost estimation. Notably, some items include alternative methods or exclusions, such as "Exclude if Bored" for certain asphalt work, which provides flexibility in construction approach. The comprehensive scope suggests a significant investment in upgrading the district's water infrastructure to improve reliability and service quality.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2024 Bid Drawings.pdf | ||
| C-522-Contract-for-Construction-of-a-Small-Project - Copy.pdf | ||
| 2024 Main and Valve Replacement.pdf | ||
| Bid Sheet R2.xlsx | XLSX spreadsheet | |
| Pre-Bid Attendees.pdf | ||
| Addendum 2.pdf | ||
| Addendum 1.pdf | ||
| Payment Bond Valve.pdf | ||
| 1971 As Builts.pdf | ||
| Performance-Bond Valve.pdf | ||
| C435-Bid-Bond-Damages-Form-2018 - Copy.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| 2024 AWSD Distribution System Upgrades | ||||||
| ID Number | Description | Quantity | Unit | Notes | Unit Price | Extended Price |
| 1 | 2" Ø SDR 21 OR HDPE | 1,106 | LF | |||
| 2 | 4" Ø C900 | 68 | LF | |||
| 3 | Remove/Reset 6' Chain Link Fence | 40 | LF | |||
| 4 | Temporary Asphalt Curb | 20 | LF | |||
| 5 | Curb & Gutter | 60 | LF | |||
| 5A | Temporary Asphalt Curb | 25 | LF | |||
| 6 | Pipe Encasment | 20 | LF | |||
| 7 | Service Line Connections | 5 | EA | |||
| 8 | 4" Gate Valve | 1 | EA | |||
| 9 | Replace Ex. 2" Gate Valve | 2 | EA | |||
| 10 | New 2" Gate Valves | 2 | EA | |||
| 11 | Pot Hole | 4 | HR | |||
| 12 | Mobilization | 1 | LS | |||
| 13 | Traffic Control | 1 | LS | |||
| 14 | Remove Curb & Gutter | 80 | LF | |||
| 15 | Remove & Replace 4" Conc. Sidewalk | 90 | SF | |||
| 16 | 2" Asphalt Trench Patch in Avondale Street | 110 | SY | Exclude if Bored | ||
| 17 | 2" Mill & Overlay in Avondale St. Ex Inter. | 544 | SY | Exclude if Bored | ||
| 18 | 2" Asphalt Overlay Parking lot | 517 | SY | |||
| 19 | 3" Asphalt in Parking Lot Trench | 67 | SY | |||
| 20 | 2" Asphalt Trench Patch in Intersection | 39 | SY | |||
| 21 | 2" Asphalt Overlay in Intersection | 366 | SY | |||
| 22 | 2" Asphalt Patch for Boring Pits | 25 | SY | |||
| 23 | 2" Mill and Overlay for Boring Pits | 100 | SY | Exclude if Open Cut | ||
| 24 | Remove Abandoned Valves from Int. | 2 | EA | |||
| 25 | Striping | 900 | LF | Hwy 50 & Avondale Blvd | ||
| 26 | Mill and Overlay for Valves and Fire Hydrants outisde of Main Replacement | 78 | SY | |||
| 26A | Slurry Seal Avondale Blvd to County Specs | 1,510 | SY | |||
| 27 | Replace Fire Hydrant | 6 | EA | |||
| 28 | Replace 6" Gate Valves | 10 | EA | |||
| 29 | C900 Pipe Replace between FH GV and FH | 120 | LF | |||
| 30 | Replace 4" GV | 1 | EA | |||
| 31 | Locate and Remove 4" GV | 1 | EA | |||
| 32 | Replace 2" GV | 7 | EA | |||
| 33 | Replace 1 1/2" GV | 1 | EA |