BID drawings Part 1 of 3 21139.pdf

PDF 5 MB Posted

Attached to
472/21139. RWG; Cotton Correctional Facility - VMS Upgrades
Solicitation number
RFQ - 171 - 230000000753
Issued by
Jackson County, Michigan

About this file

This document contains bid drawings for a Video Management System (VMS) upgrade project at the G. Robert Cotton Correctional Facility in Jackson, Michigan. The project involves the installation of new security cameras, network cabinets, uninterruptible power supplies (UPS), and associated cabling and connectivity. The bid attachments include electrical drawings, equipment specifications, and installation details. Bids are due by August 31, 2023, with questions to be emailed to the procurement contact. The project will be awarded to a qualified contractor, with the contract term and any renewal options not specified.

Regarding pricing, the bid does not mention any set-aside requirements or incumbent contractors. The project appears to be funded through state and local sources, though the specific funding amounts are not provided. Contractors will be responsible for providing all required components, raceways, wire, and hardware as indicated on the drawings.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST:

TC101 SECURITY LEGENDS, DETAILS AND SCHEDULES

TC102 DATA CABLING AND SECURITY MOUNTING DETAILS

TC103 DATA CABLING AND SECURITY MOUNTING DETAILS

TC104 NEW CAMERA ON POLE CONNECTIVITY & SURGE PROTECTION

TC105 FIBER BACKBONE CONNECTIVITY

TC106 RACK LAYOUTS

TC107 RACK LAYOUTS

TC108 RACK LAYOUTS

TC109 RACK LAYOUTS

TC110 SECURITY CAMERA ONE LINE DIAGRAMS

TC111 SECURITY CAMERA ONE LINE DIAGRAMS

TC112 SECURITY CAMERA ONE LINE DIAGRAMS

TC113 SECURITY CAMERA ONE LINE DIAGRAMS

TC114 SECURITY CAMERA ONE LINE DIAGRAMS

TC115 SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER

TC201 100 ADMIN BUILDING FIRST FLOOR - EXISTING

TC202 100 ADMIN BUILDING SECOND FLOOR - EXISTING

TC203 BRAILE MAIN FLOOR - EXISTING

TC204 300 EDUCATION BASEMENT - EXISTING

TC205 300 EDUCATION FIRST FLOOR - EXISTING

TC206 300 EDUCATION SECOND - EXISTING

TC207 HOUSING UNIT 1 MAIN FLOOR - EXISTING

TC208 HOUSING UNIT 2 MAIN FLOOR - EXISTING

TC209 HOUSING UNIT 3 MAIN FLOOR - EXISTING

TC210 HOUSING UNIT 400 FIRST FLOOR - AREA A - EXISTING

TC211 HOUSING UNIT 400 FIRST FLOOR - AREA B - EXISTING

TC212 HOUSING UNIT 400 SECOND FLOOR - AREA A - EXISTING

TC213 HOUSING UNIT 400 SECOND FLOOR - AREA B - EXISTING

TC214 HOUSING UNIT 500 FIRST FLOOR - EXISTING

TC215 HOUSING UNIT 500 SECOND FLOOR - EXISTING

TC216 HOUSING UNIT 700 FIRST FLOOR - AREA A - EXISTING

TC217 HOUSING UNIT 700 FIRST FLOOR - AREA B - EXISTING

TC218 HOUSING UNIT 700 SECOND FLOOR - AREA A - EXISTING

TC219 HOUSING UNIT 700 SECOND FLOOR - AREA B - EXISTING

TC220 PRISONER STORE - EXISTING

TC221 200 SUPPORT SERVICES FIRST FLOOR - AREA A - EXISTING

TC222 200 SUPPORT SERVICES FIRST FLOOR - AREA B - EXISTING

TC223 200 SUPPORT SERVICES FIRST FLOOR - AREA C - EXISTING

TC224 200 SUPPORT SERVICES SECOND FLOOR - AREA A - EXISTING

TC225 200 SUPPORT SERVICES SECOND FLOOR - AREA B - EXISTING

TC226 600 WAREHOUSE BUILDING - AREA A - EXISTING

TC227 600 WAREHOUSE BUILDING - AREA B - EXISTING

TC228 SITE PLAN - EXISTING

TC301 100 ADMIN BUILDING FIRST FLOOR - NEW & ADDITIONAL

TC302 100 ADMIN BUILDING SECOND FLOOR - NEW & ADDITIONAL

TC303 BRAILE BUILDING MAIN FLOOR - NEW & ADDITIONAL

TC304 300 EDUCATION BASEMENT - NEW & ADDITIONAL

TC305 300 EDUCATION FIRST FLOOR - NEW & ADDITIONAL

TC306 300 EDUCATION SECOND - NEW & ADDITIONAL

TC307 HOUSING UNIT 1 MAIN FLOOR - NEW & ADDITIONAL

TC308 HOUSING UNIT 2 MAIN FLOOR - NEW & ADDITIONAL

TC309 HOUSING UNIT 3 MAIN FLOOR - NEW & REPLACE

TC310 HOUSING UNIT 400 FIRST FLOOR - AREA A - NEW & ADDITIONAL

TC311 HOUSING UNIT 400 FIRST FLOOR - AREA B - NEW & ADDITIONAL

TC312 HOUSING UNIT 400 SECOND FLOOR - AREA A - NEW & ADDITIONAL

TC313 HOUSING UNIT 400 SECOND FLOOR - AREA B - NEW & ADDITIONAL

TC314 HOUSING UNIT 500 FIRST FLOOR - NEW & ADDITIONAL

TC315 HOUSING UNIT 500 SECOND FLOOR - NEW & ADDITIONAL

TC316 HOUSING UNIT 700 FIRST FLOOR - AREA A - NEW & ADDITIONAL

TC317 HOUSING UNIT 700 FIRST FLOOR - AREA B - NEW & ADDITIONAL

TC318 HOUSING UNIT 700 SECOND FLOOR - AREA A - NEW & ADDITIONAL

TC319 HOUSING UNIT 700 SECOND FLOOR - AREA B - NEW & ADDITIONAL

TC320 PRISONER STORE - NEW & ADDITIONAL

TC321 200 SUPPORT SERVICES FIRST FLOOR - AREA A - NEW & ADDITIONAL

TC322 200 SUPPORT SERVICES FIRST FLOOR - AREA B - NEW & ADDITIONAL

TC323 200 SUPPORT SERVICES FIRST FLOOR - AREA C - NEW & ADDITIONAL

TC324 200 SUPPORT SERVICES SECOND FLOOR - AREA A - NEW & ADDITIONAL

TC325 200 SUPPORT SERVICES SECOND FLOOR - AREA B - NEW & ADDITIONAL

TC326 600 WAREHOUSE BUILDING - AREA A - NEW & ADDITIONAL

TC327 600 WAREHOUSE BUILDING - AREA B - NEW & ADDITIONAL

TC328 SITE PLAN - NEW & ADDITIONAL

STATE OF MICHIGAN

G. ROBERT COTTON CORRECTIONAL FACILITY

VIDEO MANAGEMENT SYSTEM UPGRADE - PHASE 1

G. ROBERT COTTON CORRECTIONAL FACILITY

FILE NUMBER: 472/21139.RWG

ELECTRICAL ENGINEER

MATRIX CONSULTING ENGINEERS, INC.

1601 EAST GRAND RIVER

LANSING, MI 48906

(517) 487-2511

SECURITY DESIGN

COMMTECH DESIGN

6581 BELDING RD. NE, SUITE 101

ROCKFORD, MI 49341

(616) 863-8132

SECURITY DRAWING INDEXELECTRICAL DRAWING INDEX

G. ROBERT COTTON CORRECTIONAL FACILITY

3500 N. Elm Road, Jackson, MI 49201

DRAWING LIST:

E-100 ELECTRICAL SYMBOLS AND ABBREVIATIONS

E-200 SITE PLAN

E-500 ELECTRICAL - ADMIN BUILDING - FIRST FLOOR

E-501 ELECTRICAL - ADMIN BUILDING - SECOND FLOOR

E-502 ELECTRICAL - BRAILE BUILDING

E-503 ELECTRICAL - EDUCATION BUILDING BASEMENT

E-504 ELECTRICAL - EDUCATION BUILDING - FIRST FLOOR

E-505 ELECTRICAL - EDUCATION BUILDING - SECOND FLOOR

E-506 ELECTRICAL - HOUSING UNIT 1 - FIRST FLOOR

E-507 ELECTRICAL - HOUSING UNIT 2 - FIRST FLOOR

E-508 ELECTRICAL - HOUSING UNIT 3 - FIRST FLOOR

E-509 ELECTRICAL - BUILDING 400 UNIT H/G - SECOND FLOOR

E-510 ELECTRICAL - BUILDING 400 UNIT F/E - SECOND FLOOR

E-511 ELECTRICAL - BUILDING 500 UNIT - SECOND FLOOR

E-512 ELECTRICAL - BUILDING 700 UNIT D/C - SECOND FLOOR

E-513 ELECTRICAL - BUILDING 700 UNIT B/A - SECOND FLOOR

E-514 ELECTRICAL - PRISONER STORE

E-515 ELECTRICAL - SUPPORT SERVICES AREA A - FIRST FLOOR

E-516 ELECTRICAL - SUPPORT SERVICES AREA C - FIRST FLOOR

E-517 ELECTRICAL - SUPPORT SERVICES AREA A - SECOND FLOOR

E-518 ELECTRICAL - SUPPORT SERVICES AREA B - SECOND FLOOR

E-519 ELECTRICAL - BUILDING 600 - FIRST FLOOR

E-800 ELECTRICAL DETAILS

E-801 ELECTRICAL DETAILS

COVER

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

POLE

PUMP

PANEL

P

PNL

PVC

PRV-

P-

PB

POLY VINYL CLORIDE

POWER ROOF VENTILATOR

PULL BOX

GENERAL CONTRACTOR

GROUND

HUMIDIFIERH-

GND

GFI

GC

GROUND FAULT INTERUPTER

ABBREVIATIONS LEGEND

POWER

SWITCH

RECEPT

SF-

SWBD

TCC

SPEC

SW

RGC

RTU-

PWR

VOLTS

WATTS

UF

V

W

UL

VL

UNO

UH-

TS

TYP

TR

ROOF TOP UNIT

RECEPTACLE

SWITCHBOARD

UNDER FLOOR

SPECIFICATIONS

RIGID GALVANIZED STEEL CONDUIT

UNLESS NOTED OTHERWISE

UNDERWRITERS' LABORATORIES, INC.

TAMPER PROOF RECEPTACLE

TAMPER PROOF SWITCH

TEMPERATURE CONTROL CONTRACTOR

VERIFY LOCATION WITH OWNER

TYPICAL

UNIT HEATER

SUPPLY FAN

WITH

WITHOUT

W/

XFMR

W/O

WP

TRANSFORMER

WEATHER PROOF

HOUR

LIGHT

JUNCTION BOX

LIGHT CONTROL

ISOLATED GROUND

HORSEPOWER

MINIMUM

MOUNT

MAKE-UP AIR UNIT

MOTOR CONTROL CENTER

MAIN LUG ONLY

MOUNTED

MOUNTING

MAXIMUM

LIGHTING

LT FLEX

MTD

MUAU-

MTG

MLO

MIN

MT

MC

MAX

MCC

LTG

IG

LC

LT

IMC

JB

HR

HVAC

HOA

HP

NORMALLY CLOSED

NOT IN CONTRACT

NORMALLY OPEN

NOT TO SCALE

NIGHT LIGHTNL

NTS

NO

NIC

NC

HAND-OFF-AUTO SELECTOR SWITCH

HEATING/VENTILATING/AIR CONDITIONING

INTERMEDIATE METAL CONDUIT

LIQUID TIGHT FLEXIBLE METAL CONDUIT

MECHANICAL CONTRACTOR

HID HIGH INTENSITY DISCHARGE

A

AC

AFF

ACU-

AHJ

AHU-

AS

B-

BC

AIC

ATS

BLDG

CHLR-

CND (C)

CKT BKR

CKT

CUH-

CU-

DISC

DFU-

EF-

EC

DWH-

EBB-

DWG

CT-

EXIST (E)

EWC

FLEX

FLA

FLR

FSES

FLUOR

EMT

ABOVE FINISHED FLOOR

AIR CONDITIONING UNIT

AMPS

ABOVE COUNTER

AIR HANDLING UNIT

AUTOMATIC TRANSFER SWITCH

AMPS INTERUPTING CAPACITY

AUTHORITY HAVING JURISDICTION

ABOVE SHELF

BOILER

BUILDING

BELOW COUNTER

CHILLER

DOMESTIC WATER HEATER

CABINET UNIT HEATER

CIRCUIT

CIRCUIT BREAKER

CONDUIT

CONDENSING UNIT

COOLING TOWER

DUCT FURNACE

DRAWING

DISCONNECT

FOOD SERVICE EQUIP. SUPPLIER

ELECTRIC WATER COOLER

ELECTRICAL CONTRACTOR

ELECTRIC BASEBOARD

ELECTRICAL METALLIC TUBING

EXISTING

EXHAUST FAN

FLOOR

FLUORESCENT

FLEXIBLE CONDUIT

FULL LOAD AMPS

EM EMERGENCY

F/S FIRE/SMOKE

FU- FURNACE

X

X

X

TVSS

VFD

TRANSIENT VOLTAGE SURGE SUPPRESSION

VARIABLE FREQUENCY DRIVEDUPLEX RECEPTACLE

DOCK LIGHT FIXTURE

TELEPHONE / DATA OUTLET

ADDENDUM NOTE

PLAN NOTE

DEMOLITION NOTE

ELECTRICAL SYMBOLS LEGEND

J

SINGLE RECEPTACLE (120 VOLT)

EMERGENCY RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

FLUSH FLOOR BOX

SURFACE FLOOR BOX

SPECIAL EQUIPMENT RECEPTACLE

TELEPHONE OUTLET

DATA OUTLET

POWER POLE

JUNCTION BOX

WALL JUNCTION BOX

PULL (JUNCTION) BOX

UNDERFLOOR JUNCTION BOX

OUTLETS

LIGHT FIXTURE

STRIP FIXTURE

IN-GRADE LIGHT FIXTURE

SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)

WALL MOUNT LIGHT FIXTURE

CEILING LIGHT FIXTURE

TRACK & FIXTURE

STREET TYPE POLE FIXTURE

POLE MOUNTED LIGHT FIXTURE

EXTERIOR WALL MOUNT LIGHT FIXTURE

WALLPACK LIGHT FIXTURE

SPECIAL PURPOSE LIGHT FIXTURE

HIGH BAY LIGHT FIXTURE

EMERGENCY EGRESS LIGHT FIXTURE

(number of heads shown)

EMERGENCY LIGHT FIXTURE

FIXTURES

SWITCHES

SINGLE-POLE SWITCH

DIMMER SWITCH

TIME SWITCH

KEY SWITCH

MANUAL MOTOR SWITCH

THERMAL OVERLOAD SWITCH

SWITCH WITH PILOT LIGHT

FOUR-WAY SWITCH

THREE-WAY SWITCH

CIRCUITRY and RACEWAYS

UNDERFLOOR DUCT

BUS DUCT

PLUGMOLD AS SPECIFIED

WIREMOLD AS SPECIFIED

FLEXIBLE PIGTAILS/CONNECTIONS

"CONDUIT RUN CONTINUES" INDICATION

END OF CONDUIT RUN, CAP AND STAKE

END OF CONDUIT RUN

HOME RUN (with circuit numbers)

CONDUIT STUB DOWN

CONDUIT STUB UP

CONDUIT INSTALLED

CONDUIT INSTALLED

SERVICE and EQUIPMENT

CAPACITOR

ENCLOSED CIRCUIT BREAKER

TRANSFER SWITCH

WIREWAY

GROUND CONNECTION PER N.E.C.

TELEPHONE TERMINAL BOARD

GENERATOR, KW SHOWN

CURRENT TRANSFORMERS

UTILITY METER, AS REQUIRED

WEATHERHEAD

PANELBOARD, FLUSH MOUNTED

PANELBOARD, SURFACE MOUNTED

COMB. STARTER (BY x/C U.O.N.)

MAGNETIC STARTER (BY x/C U.O.N.)

DISCONNECT SWITCH (fuse size shown)

TRANSFORMER

DESIGNATIONS(by E.C.)

(by others)

TT

G

WW

CT

TS

T

1,3

OR

PM

WM

BD

UFD

F S

J

J

D

PP

J

CEILING MOUNTED WIFI

SSCP

COCCTV

SECURITY SYSTEM CONTROL PANEL

CAMERA

SOUND and SIGNAL

DATA RACK

RACK MOUNTED UPS

FLOOR UPS

DR

RUPS

FUPS

WALL MOUNTED UPSWUPS

POLEP

C

GENERAL ELECTRICAL NOTES

1. ALL WALL AND FLOOR PENETRATIONS THROUGH FIRE RATED WALLS

ARE TO BE SEALED WITH FIRE CAULK TO MAINTAIN ORIGINAL RATING.

2. ALL NON-FIRE RATED WALLS ARE TO BE PATCHED WITH LIKE

MATERIAL TO MAINTAIN ORIGINAL RATING.

3. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING

AND STRUCTURAL STEEL.

4. CONTRACTORS SHALL VISIT THE PROJECT SITE DURING PRE-BID

WALK THROUGH TO DETERMINE THE EXACT EXTENT OF THE

DEMOLITION WORK REQUIRED BEFORE BIDDING THE PROJECT.

5. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND

UNUSED EQUIPMENT WHERE WORK IS BEING DONE EXCEPT ITEMS

NOTED OTHERWISE.

6. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF

OLD WORK, SURFACES SHALL BE PATCHED TO MATCH ADJACENT.

7. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL

REMAIN CONCEALED AND DOES NOT INTERFERE WITH ANY NEW

WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL

CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND THEN

PATCHED AND PAINTED TO MATCH, OR AS NOTED.

8. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE

MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.

PROVIDE ALL REQUIRED CUTTING AND PATCHING.

9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING

WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE

MOUNTED EQUIPMENT.

10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS

PRIOR TO INSTALLING SERVICE TO EQUIPMENT.

11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND

CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO

ENGINEER FOR CLARIFICATION.

12. MINIMUM RACEWAY SIZE; 3/4" TRADE SIZE. REFER TO SPECIFICATION

260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS.

13. ALL CONDUIT ABOVE 10 FOOT SHALL MEET THE FOLLOWING

REQUIREMENTS:

13.1. STRAP DISTANCE: 5 FEET.

13.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.

13.3. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED-

GRC.

13.4. FITTINGS: COMPRESSION.

13.5. BELL BOXES: FS TYPE.

13.6. NO KNOCKOUTS.

13.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND

ENCLOSURES.

14. ALL CONDUIT BELOW 10 FOOT SHALL MEET THE FOLLOWING

REQUIREMENTS:

14.1. STRAP DISTANCE: 3 FEET.

14.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.

14.3. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED -

GRC.

14.4. FITTINGS: COMPRESSION.

14.5. BELL BOXES: FS TYPE.

14.6. NO KNOCKOUTS.

14.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND

ENCLOSURES

15. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE

WIRING ABOVE CEILINGS IS ACCEPTABLE.

16. CONDUITS AND WIRES SHALL BE INSTALLED STRAIGHT AND LEVEL

AND SHALL BE PARALLEL OR PERPENDICULAR TO THE BUILDING

LINES.

17. CONTRACTOR SHALL VERIFY ALL VOLTAGES BEFORE CONNECTING

ANY EQUIPMENT.

18. ALL LOCATIONS WHERE THE WALLS CAN'T BE FISHED SHALL BE

SURFACE MOUNTED CONDUIT FOLLOWING NOTES 11 AND 12 ABOVE.

19. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE

CUT INTO WALL.

20. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE RNC,

TYPE EPC-40-PVC

21. ANY ELECTRICAL OUTAGE SHALL NOT LAST OVER 2-HOURS. FOR

OUTAGES OVER PORTABLE GENERATORS SHALL BE USED TO

REPLACE ANY ELECTRICAL SERVICE EXCEEDING THAT DURATION.

22. UPON RELOCATING CAMERAS CONTRACTOR SHALL VERIFY THAT

THE CAMERAS ARE WORKING PROPERLY PRIOR TO LEAVING THE

SITE.

23. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED

COMPONENTS, RACEWAYS, WIRE, AND HARDWARE, AS INDICATED ON

DRAWINGS.

24. ALL WORK DONE WITHOUT APPROVED SHOP DRAWINGS IS AT

CONTRACTORS RISK.

25. CONTRACTOR SHALL PERFORM AN ELECTROMAGNETIC

INVESTIGATION USING GROUND PENETRATION RADAR (GPR) PRIOR

TO WORK BEING DONE. SEE SPECIFICATION SECTION 023123.

EXISTING 20KVA UPS - EQUIPMENT SPECIFICATION

20KVA UNINTERRUPTIBLE POWER SUPPLY (UPS)

PROVIDE 13 MINUTE ENERGYS SEALED CELL VRLA HX150-FR BATTERIES.

INCLUDES SYSTEM START-UP SERVICES, USER TRAINING AND TWO-YEAR,

ON-SITE WARRANTY SERVICE FOR PARTS & LABOR.

SEQUENCE OF EQUIPMENT INSTALL:

1. REMOVE EXITING BATTERIES.

2. INSTALL NEW BATTERIES.

3. VERTIV TECH TO RESET BATTERY REPLACEMENT TIMER FOR 5

YEARS.

NEW 1500VA UPS- EQUIPMENT SPECIFICATION

1500VA UNINTERRUPTIBLE POWER SUPPLY (UPS)

PROVIDE UNINTERRUPTIBLE POWER SUPPLY (UPS). UPS SHALL BE

1.5KVA RATED, HIGH EFFICIENCY, DOUBLE CONVERSION, CONTINUOUS

DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 3-WIRE

PLUS GROUND. OUTPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 4-WIRE

PLUS GROUND. INCLUDE ALARM RELAY BOARD FOR REMOTE

MONITORING, LITHIUM ION BATTERIES, 13 MINUTE RUN TIME, SELF

DIAGNOSTICS. NEMA 5-15 PLUG WITH (6) NEMA 5-15R RECEPTACLES.

INCLUDE A VERTIVE WALL MOUNT BRACKET, PART NUMBER WMBKT2U.

INCLUDE 5 EAR ON-SITE WARRANTY SERVICE FOR PARTS AND LABOR.

SEQUENCE OF EQUIPMENT INSTALL:

1. INSTALL NEW WALL MOUNT BRACKET.

2. INSTALL NEW 1500VA WALL, FLOOR, OR RACK UPS AS SHOWN IN

DRAWINGS.

3. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.

4. REMOVE OLD UPS.

E-100

ELECTRICAL SYMBOLS

AND ABBREVIATIONS

DRK

JFS

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

2 2

(1) 1" PVC

(1) 1" PVC

(1) 1" PVC

(1) 1" PVC

(1) 1" PVC

(1) 1" PVC

(1) 1" PVC

(1) 1-1/2" PVC

HAND HOLE

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL NEW SURGE PROTECTION

DEVICES AND JUNCTION BOX FOR CAMERAS ON POLE.

SEE SHEET E-800 DETAIL 3.

PROVIDE AND INSTALL SURGE PROTECTION DEVICES

IN COMMUNICATIONS ROOM TO CAMERAS ON

BUILDING. SEE SHEET E-800 DETAIL 2.

PROVIDE AND INSTALL SURGE PROTECTION DEVICES

IN PERIMETER CABINETS. SEE SHEET E-800 DETAIL 1.

PROVIDE AND INSTALL NEW QUAZITE JUNCTION BOX

OR EQUAL FOR HAND HOLE. EQUALS SHALL BE

PRE-APPROVED PRIOR TO INSTALLATION.

DIRECTIONALLY BORE ALL CONDUIT TO BE INSTALLED.

SEE DRAWINGS FOR SIZE AND QUANTITY.

E-200

DRK

JFS

SITE PLAN

N ELECTRICAL - SITE PLAN

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

900 105 20 180

SCALE: 1" = 90'-0"

UP

UPS-A 1

UPS-A 3

UPS-A 5

UPS-A 4

UPS-A 2 UPS-A 6

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA SYSTEM

UPS UNITS. RE-FEED EXISTING RECEPTACLE FROM NEW

PANEL "UPS-A" TO SUPPLY POWER FOR ALL SECURITY

CAMERA EQUIPMENT. PROVIDE AND INSTALL NEW BREAKERS

AS REQUIRED.

PROVIDE AND INSTALL NEW 20A RECEPTACLE FROM NEW

PANEL "UPS-A". PROVIDE AND INSTALL NEW BREAKERS AS

REQUIRED. VERIFY MOUNTING HEIGHTS WITH OWNER.

E-500

ELECTRICAL - ADMIN

BUILDING FIRST FLOOR

DRK

JFS

N COTTON ADMIN BUILDING 100 - FIRST FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

DWN

DWN

DWN

DWN

EXISTING

20KVA XFMR

EXISTING

20KVA UPS

NEW SUB

PANEL "UPS-A"

1 1

UPS-A 8

PANEL

NEW SUB

UPS-A

120/208V 3Ø, 3W

40A / MCB

EXISTING 30 KVA XFMR

PRIMARY: 480V

SECONDARY: 208V

208 VOLTS

208 VOLTS

208 VOLTS

480 VOLTS

480 VOLTS

480 VOLTS

EXISTING 20KVA UPS

EXISTING

EXISTING

EXISTING

(3) #8 AWG

(1) #10 AWG GND

(1) 1" CND

90A

25A / 3P

25A / 3P

FROM EMPB

40A / 3P

TO EXISTING SITE CABINETS

REVISED 20 KVA UPS ONE-LINE DIAGRAM

SCALE: N.T.S.

70A

EXISTING 20 KVA XFMR

PRIMARY: 208V

SECONDARY: 480V

TO EXISTING SITE CABINETS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA

EQUIPMENT UPS UNITS. RE-FEED EXISTING 30A

RECEPTACLES FROM NEW UPS SUB PANEL "UPS-A". PROVIDE

AND INSTALL NEW BREAKER AS REQUIRED.

PROVIDE AND INSTALL NEW BATTERIES IN EXISTING 20KVA

UPS UNIT. SEE 20KVA UPS SPECIFICATION ON SHEET E-100.

E-501

ELECTRICAL - ADMIN

BUILDING SECOND

FLOOR

DRK

JFS

N

COTTON ADMIN BUILDING 100 - SECOND FLOOR -

ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

RUPS

FUPS

FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP ALL SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA PLUG IN UPS UNIT

USING BRACKET TO BACK UP ALL SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-502

ELECTRICAL - BRAIL

BUILDING

DRK

JFS

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

N COTTON BRAILE BUILDING - MAIN FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

RU

PS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT USING BRACKET TO BACK UP ALL SECURITY

CAMERA EQUIPMENT IN EXISTING RACK. SEE SHEET E-800

DETAIL 8.

E-503

ELECTRICAL - EDUCATION

BUILDING BASEMENT

DRK

JFS

N COTTON EDUCATION BUILDING 300 - BASEMENT - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

DN

UP

UP

DN

UP

FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW PLUG IN 1500VA UPS UNIT

USING BRACKET TO BACK UP ALL EXISTING SECURITY

CAMERA EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-504

ELECTRICAL - EDUCATION

BUILDING FIRST FLOOR

DRK

JFS

N COTTON EDUCATION BUILDING 300 - FIRST FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

UP

DN

DN

RUPS

FUPS

FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS UNITS.

PROVIDE AND INSTALL NEW RACK MOUNTED 1500VA UPS UNIT

USING TO BACK UP EXISTING SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS UNITS.

PROVIDE AND INSTALL NEW PLUG IN 1500VA UPS UNIT USING

BRACKET TO BACK UP ALL EXISTING SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-505

ELECTRICAL - EDUCATION

BUILDING SECOND

FLOOR

DRK

JFS

N

COTTON EDUCATION BUILDING - SECOND FLOOR -

ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

PA

RT

"T E"

PA

RT

"T F"

RUPS

FUPS

2FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP ALL SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA PLUG IN UPS UNIT

USING BRACKET TO BACK UP ALL SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-506

ELECTRICAL - HOUSING

UNIT 1 FIRST FLOOR

DRK

JFS

N COTTON HOUSING UNIT 1 - MAIN FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

PA

RT

"T C"

PA

RT

"T D"

RUPS

FUPS

2FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP ALL SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA PLUG IN UPS UNIT

USING BRACKET TO BACK UP ALL SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-507

ELECTRICAL - HOUSING

UNIT 2 FIRST FLOOR

DRK

JFS

N COTTON HOUSING UNIT 2 - MAIN FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

PA

RT

"T A"

PA

RT

"T B"

RUPS

FUPS

2FUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP ALL SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA PLUG IN UPS UNIT

USING BRACKET TO BACK UP ALL SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-508

ELECTRICAL - HOUSING

UNIT 3 FIRST FLOOR

DRK

JFS

N COTTON HOUSING UNIT 3 - MAIN FLOOR - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

DN

UPUP

UP

UP

UP

UP

DN

RAMP

RUPS

PA

RT

"A

PA

RT

"B

PA

RT

"A

PA

RT

"B

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-509

ELECTRICAL - BUILDING

400 - UNIT H/G - SECOND

FLOOR

DRK

JFS

N

COTTON HOUSING UNIT 400 - SECOND FLOOR -

AREA A - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

KEY PLAN

AREA BAREA A

UP

UP

DN

UP

UP

UP

UP

RAMP

RAMP

RUPS

PA

RT

"A

PA

RT

"B

PA

RT

"A

PA

RT

"B

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-510

ELECTRICAL - BUILDING

400 - UNIT F/E - SECOND

FLOOR

DRK

JFS

N

COTTON HOUSING UNIT 400 - SECOND FLOOR -

AREA B - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

RAMP

RUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-511

ELECTRICAL - BUILDING

500 SECOND FLOOR

DRK

JFS

N

COTTON HOUSING UNIT 500 - SECOND FLOOR -

ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

DN

UPUP

UP

UP

UP

UP

DN

RUPS

PA

RT

"A

PA

RT

"B

PA

RT

"A

PA

RT

"B

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-512

ELECTRICAL - BUILDING

700 - UNIT D/C - SECOND

FLOOR

DRK

JFS

N

COTTON HOUSING UNIT 700 - SECOND FLOOR -

AREA A - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

UPUP

UP

UP

DN

UP

UP

UP

UP

RUPS

PA

RT

"A

PA

RT

"B

PA

RT

"A

PA

RT

"B

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-513

ELECTRICAL - BUILDING

700 - UNIT B/A - SECOND

FLOOR

DRK

JFS

N

COTTON HOUSING UNIT 700 - SECOND FLOOR -

AREA B - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

RUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-514

ELECTRICAL - PRISONER

STORE

DRK

JFS

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

N COTTON PRISONER STORE - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

UP

UP

FUPS

RUPS

PA

RT

"A

PA

RT

"B

PART "C"

PART "A"

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA PLUG IN UPS

USING BRACKET TO BACK UP SECURITY CAMERA

EQUIPMENT. SEE SHEET E-800 DETAIL 7.

E-515

ELECTRICAL - SUPPORT

SERVICES - AREA A -

FIRST FLOOR

DRK

JFS

N

COTTON SUPPORT SERVICES - FIRST FLOOR -

AREA A - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

KEY PLAN

AREA A

AREA C

AREA B

RUPS

PART "C"

PART "A"

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-516

ELECTRICAL - SUPPORT

SERVICES - AREA C -

FIRST FLOOR

DRK

JFS

N

COTTON SUPPORT SERVICES - FIRST FLOOR -

AREA C - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

KEY PLAN

AREA A

AREA C

AREA B

UP

DN

DN

UP

DN

RUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-517

ELECTRICAL - SUPPORT

SERVICES - AREA A -

SECOND FLOOR

DRK

JFS

N

COTTON SUPPORT SERVICES - SECOND FLOOR -

AREA A - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

AREA A AREA B

DN

DN

RUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-518

ELECTRICAL - SUPPORT

SERVICES - AREA B -

SECOND FLOOR

DRK

JFS

N

COTTON SUPPORT SERVICES - SECOND FLOOR -

AREA B - ELECTRICAL

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a tr ix

RUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL EXISTING SECURITY CAMERA UPS

UNITS. PROVIDE AND INSTALL NEW 1500VA RACK MOUNTED

UPS UNIT TO BACK UP SECURITY CAMERA EQUIPMENT IN

EXISTING RACK.

E-519

ELECTRICAL - BUILDING

600 - FIRST FLOOR

DRK

JFS

N COTTON WAREHOUSE BUILDING 600 - ELECTRICAL

SCALE: 3/32" = 1'-0"

10 5 10 20 26

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

CAMERA JUNCTION BOX INSTALLATION DETAIL

SCALE: N.T.S.

#10 AWG

#10 AWG

#10 AWG

#10 AWG

ETHERNET SWITCH

CABINET

LIGHTING ARRESTORS

ELECTRICAL EQUIPMENT

TYPICAL FOR

EACH PIECE OF

EQUIPMENT

CONNECT TO GROUND BAR

#10 AWG

TELECOMMUNICATIONS

GROUND BAR

GROUND BAR TYPICAL

TYPICAL CRIMP LUG CONNECTIVITY

1. ALL GROUNDING CONNECTIONS SHALL BE ROUTED TO CLOSEST

GROUND BAR.

2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE

CONNECTED TO THE EARTH, ELECTRICAL GROUNDING SYSTEM,

AND POLE.

3. ALL BONDING CONNECTIONS SHALL BE MAKE WITH TWO HOLE

CRIMP LUGS ONLY AT THE GROUND BAR.

4. FROND CONNECTIONS SHALL BE MAKE WITH A MINIMUM OF #10

AWG CABLE.

5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.

GROUNDING NOTES

COMMUNICATIONS GROUNDING DETAIL

SCALE: N.T.S.

BUILDING MOUNTED CAMERA SURGE PROTECTION DETAIL

SCALE: N.T.S.

PATCH PANEL

DATA SWITCH

TO CAMERA

NEW SURGE PROTECTOR

TO GROUND BUS TYP.

GRADE

POLE MOUNTED CAMERA DETAIL - WITH HAND HOLE

SCALE: N.T.S.

GROUND ROD

CADWELD

HANDHOLE

NEW 1" TYPE C

JUNCTION BOX

NEW JUNCTION BOX

NEW 1" PVC (CAMERA CABLE) FROM

CABINET

NEW1" RGS LOW

VOLTAGE CONDUIT

NEW CAMERA. SEE SHEET E-800

DETAIL 4 FOR MOUNTING HEIGHTS

NEW 1" CONDUIT

NEW CAMERA BACK BOX

NEW PVC CONDUIT

(MATCH EXISTING)

NEW PVC COUPLING

NEW HAND HOLE

3/4" RIGID CONDUIT TO

CAMERA

CONDUIT TO

UNDERGROUND CONDUIT

NEW SURGE

SUPPRESSOR

RAYCAP NJ2010B

NEW 8"W X 8"H X 4"D

ENCLOSURE, NEMA 3R, HINGED

JUNCTION BOX HOFFMAN

A10R86HCR

PROVIDE WITH PAD

LOCKABLE LATCH

STAINLESS

STEEL PIPE

STRAP, TYP.

STEEL

CHANNEL,

UNISTRUT OR

EQUAL

GROUND WIRE

POLE

GROUND WIRE.

CONNECT TO GROUND

BAR. JUMPER TO TSS

WITH #12AWG

SIDE VIEWFRONT VIEW

NEW 1"x3"x1/4" TK.

COPPER GROUND

BAR

GROUND WIRE TO

CAMERA GROUND LUG

CAT6 CABLE

TSS

CAT6 CABLE

1500VA WALL BRACKET DETAIL

SCALE: N.T.S.

1500VA UPS UNIT

TOP BRACKET

BOTTOM BRACKET

SCREW SECURING BRACKET TO WALL

(TYPICAL) REPEAT ON BOTTOM BRACKET

SCREW SECURING BRACKET TO UPS UNIT

(TYPICAL) REPEAT ON BOTTOM BRACKET

EXISTING POWER

STRIP FED FROM

UPS

NEW SURGE PROTECTION DEVICES

EXISTING POE INJECTORS

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX

EXISTING TYPICAL

COMMUNICATION CONDUITS TO

LIGHT POLES AND OTHER

CABINETS

EXISTING GROUND BAR

NEW CAT 6 CABLES TO

CAMERAS

EXISTING CAT 6 CABLES TO

CAMERAS

NEW CAT 6 CABLES TO

CAMERAS

EXISTING 2'X2'

FIREPROOF PLYWOOD

WALL FIELD

NEW CAT 6 CABLES TO

CAMERAS

NEW CAT 6 CABLES TO

CAMERAS

EXISTING CAT 6 CABLES TO

CAMERAS

NEW CAT 6 CABLES TO

CAMERAS

NEW CAT 6 CABLES TO

CAMERAS

CAT-6 PATCH CABLES

ADD D-RINGS AS REQUIRED

WALL FIELD BUILD-OUT FOR CAMERAS ON POLES FED FROM BUILDINGS DETAIL

SCALE: N.T.S.

EXISTING MOUNTING

POLE

EXISTING TYPICAL

COMMUNICATIONS

CONDUITS TO LIGHT

POLES AND OTHER

CABINETS

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX

EXISTING MODULAR JACKS

IN SURFACE MOUNT BOX

EXISTING MODULAR JACKS

IN SURFACE MOUNT BOX

EXISTING MOUNTING

POLE

NEW SURGE

PROTECTION

DEVICES

EXISTING POE INJECTORS

EXISTING POWER

SUPPLY FOR

ETHERNET

SWITCH- TO

REMAIN

EXISTING

ETHERNET

SWITCH

FUTURE

SWITCH

EXISTING POWER

SUPPLY FOR

ETHERNET

SWITCH- FUTURE

EXISTING FIBER OPTIC

PATCH PANEL

RESERVED FOR ELECTRICAL

EXISTING PLUG STRIP

EXISTING GROUND BAR

NETWORK CABINET DETAIL - TYPICAL FOR PERIMETER CABINETS

SCALE: N.T.S.

TO UPS

TO POWER SOURCE

GROUND CABLES

CAT-6 PATCH CABLES

GROUND CABLES

E-800

DRK

JFS

ELECTRICAL DETAILS

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

PLAN

24"

ELECTRICAL

COMPOSITE GASKETED BOX, QUAZITE OR EQUAL. EQUALS

SHALL BE PRE-APPROVED PRIOR TO BIDDING.

HEAVY DUTY, SKID-RESISTANT

COVER, BOLT-DOWN TYPE, TAMPER

RESISTANT HARDWARE

3" MIN. SAND OR

GRANULAR BACKFILL

4 ELECTRICAL HANDHOLE DETAIL

SCALE:NTS

LIFTING EYE

FINISHED GRADE

UNDISTURBED EARTH

CONDUIT

SECTION

TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM - NEW POLE WITH HANDHOLE

SCALE: N.T.S.

CAB-XXX

ETHERNET

SWITCH

POE

INJECTOR

SURGE

PROTECTOR

SURGE

PROTECTOR

TYP. PERIMETER CABINET

CONNECT TO GROUND

BAR #10 AWG TYP.

EXISTING CAT-6 CABLE IN

CONDUIT

NEW JUNCTION BOX

HOFFMAN #A10R86HRC

NEW FIXED

CAMERA

NEW SURGE

PROTECTION

NEW HAND HOLE

NEW PTZ

CAMERA

NEW PVC

(MATCH EXISTING)

NEW PVC

(MATCH EXISTING)

NEW 1" RGS LOW

VOLTAGE CONDUIT

NEW 1" RGS LOW

VOLTAGE CONDUIT

NEW JUNCTION BOX

HOFFMAN #A10R86HRC

TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM - NEW POLE NO HANDHOLE

SCALE: N.T.S.

CAB-XXX

ETHERNET

SWITCH

POE

INJECTOR

SURGE

PROTECTOR

SURGE

PROTECTOR

TYP. PERIMETER CABINET

CONNECT TO GROUND

BAR #10 AWG TYP.

EXISTING CAT-6 CABLE IN

CONDUIT

NEW JUNCTION BOX

HOFFMAN #A10R86HCR

EXISTING

FIXED

CAMERA

NEW SURGE

PROTECTION

EXISTING

PTZ

CAMERA

NEW JUNCTION BOX

HOFFMAN #A10R86HCR

CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

GRADE

POLE MOUNTED CAMERA DETAIL - EXISTING POLE

SCALE: N.T.S.

FIXED CAMERA MOUNTING

HEIGHT

16' AFG MINIMUM

OR 2' ABOVE

RAZORWIRE

MINIMUM

NEW JUNCTION BOX

PTZ CAMERA MOUNTING HEIGHT

NEW 1" RIGID CONDUIT

EXISTING CAMERA

BACK BOX

22' AFG MINIMUM

OR 2' ABOVE

RAZORWIRE

MINIMUM

EXITING POLE

E-800

NEW HAND HOLE

GRADE GRADE

CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

EXITING CONDUIT

E-801

DRK

JFS

ELECTRICAL DETAILS

C om m te ch D es ig n

472/21139.RWG

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472JCFmaintproj consultant job no.

1065_24B sheet title

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Y22017

C O

U R

TL

AN

D S

T.

, S

U

IT

E

R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY FLOOR

PLANS

08/31/2023BID SET

M a

TC101

TYPICAL PERIMETER CAMERA CABLE LABELS

AT FACEPLATE & PATCH PANEL

TC101

FIBER OPTIC CABLE AT PERIMETER CABINETS

LABELING AT PATCH PANEL

TC101

COMMUNICATIONS GROUNDING DETAIL

TC101

FIBER OPTIC PANEL

LABELING DETAIL

TC101

UTP PATCH PANEL (TYP)

TC101

TYPICAL DATA CABLE LABELING

AT FACEPLATE AND PATCH PANEL

TC101

TYPICAL FACEPLATE LABELING

COMMUNICATION CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

SECURITY EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

SECURITY SYMBOL LEGEND

SYMBOL DESCRIPTION

PC

LT

TC101

CONNECTIVITY CODE

NETWORK EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

COMMUNICATION EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

CAMERA EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO. DROP

CEILING

HARD

CEILING/WAL

L

BUILDING

EXTERIOR

BUILDING

EXTERIOR

CORNER

POLE MOUNT

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC101

COTTON

SECURITY, LEGENDS,

DETAILS AND SCHEDULES

TC102

NEW PC AND MONITOR

FOR CAMERA SYSTEM

TC102

CONNECTIVITY CODE

TC102

CONNECTIVITY CODE

TC102

NEW PC FOR CAMERA SYSTEM

REPLACE EXISTING

P2

P4

P6

P8

P1

P3

P5

100/1000 SFP

P10 Link/ActiveP9

Console

FAULT

9600.N.8.1

PWR2

PWR1

R.M.

PWR

Communication Networks

TM

www.comnet.net 203-796-5300

P7

10/100/1000T

100/1000 SFP

10/100/1000T

P9

P10

P7 P8 P5 P6 P3 P4 P1 P2

PoE

MEAN WELLDRP-240-48

SWITCHING REGULATOR

POWER FACTOR CORRECTION

INPUT: 100-240VAC 3.5A

OUTPUT: 48V 5.0A

MADE IN TAIWAN

LN-V-V+V+V

DC OK

CNGE2FE8MSPOE

P2

P4

P6

P8

P1

P3

P5

100/1000 SFP

P10 Link/ActiveP9

Console

FAULT

9600.N.8.1

PWR2

PWR1

R.M.

PWR

Communication Networks

TM

www.comnet.net 203-796-5300

P7

10/100/1000T

100/1000 SFP

10/100/1000T

P9

P10

P7 P8 P5 P6 P3 P4 P1 P2

PoE

MEAN WELLDRP-240-48

SWITCHING REGULATOR

POWER FACTOR CORRECTION

INPUT: 100-240VAC 3.5A

OUTPUT: 48V 5.0A

MADE IN TAIWAN

LN-V-V+V+V

DC OK

TC102

NETWORK CABINET DETAIL

TYPICAL FOR PERIMETER CABINETS 4

TC102

WALLFIELD BUILD-OUT FOR CAMS ON POLES

THAT ARE FED FROM A BUILDING

TC102

NEW MINI PC FOR CAMERA SYSTEM

REPLACE EXISTING

TC102

NEW MINI PC FOR CAMERA SYSTEM

PC1-MINI-NEW

PC1-MINI-REP

PC-NEW

PC-REP

TC102

NEW LAPTOP FOR CAMERA SYSTEM

REPLACE EXISTING

LT-NEW

TC102

NEW MINI PC AND MONITORING STATION

REPLACE EXISTING

PC2-MINI-REP

TC102

NEW MINI PC AND MONITORING STATION

PC2-MINI-NEW

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC102

COTTON DATA

CABLING AND SECURITY

MOUNTING DETAILS

TC103

SECURITY CAMERA

CONNECTIVITY CODE

TC103

SECURITY CAMERA

CONNECTIVITY CODE 7

TC103

INTERIOR CORNER MOUNT CAMERA

RACEWAY & SEALANT DETAIL

TC103

PARAPET MOUNT

CAMERA INSTALLATION

TC103

HARD CEILING MOUNT CAMERA RACEWAY

/SEALANT & CABLE LADDER DETAILS

TC103

TYPICAL OPEN-CEILING (PENDANT)

CAMERA INSTALLATION

TC103

TYPICAL DRYWALL OR DROP-CEILING

CAMERA INSTALLATION6

TC103

TYPICAL INTERIOR WALL/CEILING MOUNT

CAMERA INSTALLATION10

TC103

EXTERIOR CORNER, WALL MOUNT

CAMERA INSTALLATION

TC103

CAMERA THROUGH WALL

RACEWAY & SEALANT DETAIL

TC103

TYPICAL DRYWALL OR DROP-CEILING

CAMERA INSTALLATION

TC103

WORK STATION

CONNECTIVITY CODE

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC103

COTTON DATA CABLING

AND SECURITY

MOUNTING DETAILS

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

TC104

CAMERA POLE MOUNTING DETAIL

TC104

TYPICAL NEW CAMERA ON POLE

ONE-LINE CONNECTIVITY

TC104

SECURITY CAMERA

SURGE/LIGHTNING PROTECTION

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC104

COTTON NEW CAMERA ON

POLE CONNECTIVITY

& SURGE PROTECTION

TC105

COTTON CORRECTIONAL FACILITY

FIBER BACKBONE CONNECTIVITY

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC105

COTTON FIBER

BACKBONE CONNECTIVITY

TC106

200 SUPPORT SERVICES BUILDING - COMM ROOM S1

RACK LAYOUT3

TC106

200 SUPPORT SERVICES BUILDING - COMM ROOM S2

RACK LAYOUT

TC106

200 SUPPORT SERVICES BUILDING - CR S3

RACK LAYOUT

TC106

200 SUPPORT SERVICES BUILDING - COMM ROOM S4

RACK LAYOUT

1.C

TC106

100 ADMIN BUILDING - COMM ROOM A3

RACK LAYOUT 1.B

TC106

100 ADMIN BUILDING - COMM ROOM A1

RACK LAYOUT 1.A

TC106

100 ADMIN BUILDING - COMM ROOM A2

RACK LAYOUT

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC106

COTTON RACK LAYOUTS

TC107

300 EDUCATION BUILDING - COMM ROOM E1

RACK LAYOUT

TC107

300 EDUCATION BUILDING - COMM ROOM E2

RACK LAYOUT

TC107

HOUSING UNIT 400 E & F - COMM ROOM EF

RACK LAYOUT

TC107

HOUSING UNIT 400 G & H - COMM ROOM GH

RACK LAYOUT

TC107

HOUSING UNIT 500 I & J - COMM ROOM IJ

RACK LAYOUT

TC107

600 WAREHOUSE BUILDING - COMM ROOM W1

RACK LAYOUT

C om m te ch D es ig n D

EP

A

R

TM

EN

T

O F

TE

C

H N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B

EL

D

IN

G R

O

AD

N E, S U

IT

E

R O

C

KF

O R

D , M

IC

H

IG

AN

W

W W

.C O

M M

TE

C

H D

ES

IG

N .C

O M

TC107