BID 2025-41 Addendum -3.pdf

PDF 7 MB Posted

Attached to
BID 2025-41 Aquatic Park Roofing Project
Solicitation number
S-C01010-00013565
Issued by
Clackamas County, Mission CDP, Oregon

About this file

Addendum #3 to Invitation to Bid #2025-41 is issued by Clackamas County for the Aquatic Park Roofing Project. The purpose of this addendum is to communicate that the Carlisle roofing 80mil product is an approved equal for the project. The addendum is dated May 13, 2025, and notes that it amends the original bid document issued on April 10, 2025. Except for the specified change regarding the Carlisle roofing material, all other terms and conditions of the original bid and subsequent addenda remain unchanged.

The addendum includes an attachment with Carlisle specifications, which provides technical details about the approved roofing material. No other substantive changes are made to the original bid documents. The addendum serves to clarify and expand the acceptable roofing materials for bidders, potentially providing more flexibility in product selection while maintaining the original project requirements.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INVITATION TO BID #2025-41

Aquatic Park Roofing Project

ADDENDUM NUMBER 3

May 13, 2025

On April 10, 2025, Clackamas County (“County”) published Invitation to Bid #2025-41 (“BID”. The County has found that it is in its interest to amend the BID through the issuance of this Addendum #3.

Except as expressly amended below, all other terms and conditions of the original BID and subsequent Addenda shall remain unchanged.

1. The Carlisle roofing 80mil is an approved equal for this project.

Attachment: Carlisle specifications.

End of Addendum

North Clackamas Aquatic Center PVC Substitution - Submittal

Logan Dailey Technical Sales Representative logan.dailey@carlisleccm.com

724-355-6371

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E

Membrane

Overview

Carlisle’s Sure-Flex PVC is an advanced-formula, heat-weldable PVC membrane that is designed for long-term weatherability and performance.

The physical properties of the membrane are enhanced by a tenacious, anti-wicking, weft-inserted polyester fabric that is encapsulated by thick PVC-based top and bottom plies. The membrane’s smooth surfaces facilitate a permanent weld for a consistent, watertight, monolithic roof assembly.

Features and Benefits

» Exceptional fire and chemical resistance

» Fully formulated monolithic top-ply for long-term weatherability

» Enhanced physical characteristics meeting ASTM D4434 Type IV requirements

» Antimicrobials throughout the polymer for increased resistance to mold, mildew, and algae growth

» Highly flexible with a wide window of weldability for ease of installation

» Available colors:

Sustainable Attributes

Carlisle SynTec Systems’ focus has always been innovation - Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Carlisle is committed to driving sustainable and efficient processes in the design and manufacturing of our products.

» PVC polymer derived from less than 50% fossil fuels

» Up to 10% pre-consumer recycled content

» Fully recyclable when used in mechanically-attached systems

» 3rd-party verified Environmental Product Declaration available

» California Title 24 compliant*

» See Radiative Properties and LEED Information tables below for additional attributes

*White only.

Installation

Installation requires minimal labor and few components, making it quick and easy to install. Sheet seams are heat-welded together using hot-air welding equipment to create a monolithic, water-tight roof system.

Sure-Flex PVC is suitable for the following roof systems:

Fully-Adhered – membrane is adhered to a suitable substrate utilizing an appropriate bonding adhesive

Mechanically Fastened – membrane is attached to a suitable substrate utilizing plates and fasteners which are overlapped with membrane

Induction-Welded – membrane is attached to a suitable substrate via an induction welding tool being placed over the membrane where a fastened PVC induction welding plate is located to weld the two components together

Review Carlisle specifications and details for complete installation information.

White Gray Tan Light Gray Slate Gray daileylo Rectangle daileylo Rectangle

Precautions

» Sunglasses that filter out ultraviolet light are strongly recommended when working on reflective membranes. Roofing technicians should dress appropriately and wear sunscreen.

» Exercise caution when walking on wet membranes; membranes may be slippery when wet or due to frost and ice buildup.

» Care must be exercised while working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible.

» Use proper stacking procedures to ensure sufficient stability of the materials.

» Store membrane in its original, undisturbed plastic wrap in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins.

» Membrane that has been exposed to the weather or contaminated with dirt must be prepared with Sure-Flex PVC/KEE HP Membrane Cleaner prior to hot-air welding.

Membrane

Supplemental Approvals, Statements and Characteristics

» Sure-Flex PVC meets or exceeds the requirements of ASTM D4434 Standard Specification for Poly (Vinyl Chloride) Sheet Roofing. Sure-Flex PVC is classified as Type III and/or Type IV as defined by ASTM D4434.

» Sure-Flex reinforced PVC was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head.

50-mil thick membrane was watertight after an impact energy of 22.5 J (16.6 ft-lbf), which passes the ASTM D4434 requirement.

» Sure-Flex reinforced PVC was tested for static puncture resistance per ASTM D5602-98 and exceeded 33 lbf (145 N), which passes the ASTM D4434 requirement.

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Typical Properties and Characteristics

Physical Property ASTM D4434 Requirement 50-mil 60-mil 80-mil

Thickness over scrim, in. (mm) ASTM D4434 optical method average of 3 areas

0.016 min (0.40) 0.022 (0.559) 0.027 (0.686) 0.037 (0.940)

Weight, lbs/ft2 (kg/m2) No requirement 0.33 (1.61) 0.40 (1.95) 0.55 (2.68)

Breaking strength (MD × CD), lbf (N) ASTM D751 grab method

275 min (1223) 320 x 300 (1423 x 1334) 330 x 300 (1468 x 1334) 360 x 330 (1601 x 1468)

Elongation break of reinforcement (MD x CD), % ASTM D751 grab method

25 min 30 x 30 30 x 30 30 x 30

Tearing strength (MD x CD), lbf (N) ASTM D751 proc. B, 8 in. x 8 in.

90 min (400) 100 x 120 (445 x 534) 100 x 130 (445 x 578) 100 x 132 (445 x 587)

Low temperature bend, ASTM D2136, no cracks 5x at -40°C

PASS PASS (-40°C) PASS (-40°C) PASS (-40°C)

Linear dimensional change, % ASTM D1204, 6 hours at 176°F

±0.5 max 0.4 0.4 0.4

Ozone resistance, no cracks 7x ASTM D1149, 100pphm, 168 hrs

PASS PASS PASS PASS

Water absorption resistance, mass % ASTM D570, 166 hours at 158°F water

±3.0 max 2.0 2.0 2.0

Field seam strength, lbf/in. (kN/m) ASTM D1876 tested in peel

No requirement 25 (4.4) min 60 (10.5) typ.

25 (4.4) min 60 (10.5) typ.

25 (4.4) min 60 (10.5) typ.

Water vapor permeance, Perms, ASTM E96 proc. B

No requirement 0.10 max 0.05 typ 0.10 max 0.05 typ 0.10 max 0.05 typ

Puncture resistance - Federal, lbf (kN) FTM 101C, method 2031

No requirement 280 320 380

Puncture resistance - Dynamic, J (ft-lbf) ASTM D5635 20 (14.7) PASS PASS PASS

Puncture resistance - Static, lbf (N) ASTM D5602 33 (145) PASS PASS PASS

Xenon-Arc resistance, no cracks/ crazing 10x, ASTM G155 0.35 W/m2 at 340-nm, 63°C B.P.T. 12,600 kJ/m2 total radiant exposure 10,000 hours

PASS PASS PASS PASS

Properties after heat aging ASTM D3045, 56 days at 176°F Breaking strength, % retained Elongation reinf., % retained

90 min 90 min 90 min 90 min 90 min 90 min 90 min 90 min

Air Permeance

ASTM E2178

No requirement PASS PASS PASS

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

02.11.25 © 2025 Carlisle.

REPRINT CODE: 605245 PVC-1024 - “Sure-Flex PVC Membrane Product Data Sheet”

Carlisle and Sure-Flex are trademarks of Carlisle.

LEED is a registered trademark of the U.S. Green Building Council.

Membrane

LEED® Information

Pre-consumer Recycled Content Up to 10%

Post-consumer Recycled Content 0%

Manufacturing Location Greenville, IL

Solar Reflectance Index (SRI), Initial White: 110, Tan: 89, Gray: 70, Light Gray: 91, Slate Gray: N/A

Radiative Properties for Cool Roof Rating Council (CRRC) and LEED Physical Property Test Method White

PVC

Tan

PVC

Gray

PVC

Light Gray

PVC

Slate Gray

PVC

CRRC - Initial Solar Reflectance

ASTM C1549 0.87 0.72 0.59 0.74 N/A

CRRC - Solar Reflectance after 3 years

ASTM C1549

(uncleaned)

0.70 0.56 0.49 0.59 N/A

CRRC - Initial Thermal Emittance

ASTM C1371 0.89 0.87 0.89 0.88 N/A

CRRC - Thermal Emittance after 3 years

ASTM C1371

(uncleaned)

0.88 0.87 0.89 0.89 N/A

Solar Reflective Index (SRI)

ASTM E1980 110 89 70 91 N/A

Solar Reflective Index (SRI) SRI after 3 years

ASTM E1980 86 65 57 70 N/A

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Overview

DensDeck Roof Board’s patented design features a gypsum core with embedded glass mat facers on the top and bottom of the board. DensDeck can be used in a variety of commercial roof systems and provides an excellent thermal barrier as well as exceptional fire, moisture, and wind uplift resistance properties.

DensDeck is primarily used as a cover board over insulation in mechanically fastened roofing applications. Frequently used in wood deck construction to achieve UL code ratings. DensDeck reduces the potential for growth of mold and mildew per ASTM D 3273.

Features and Benefits

» UL code ratings available for (class A, B, C) unlimited slopes and wood decks

» FM Approved

» Improves resistance to foot traffic

» Excellent wind uplift ratings

» Resistant to deterioration, warping, and jobsite damage

» 5⁄8" DensDeck can replace any generic Type “X” gypsum board in any roof assembly in the UL Fire Resistance Directory under the prefix “P”

Installation

DensDeck may be secured with Flexible FAST™ Adhesive, fastened in accordance with an approved fastening pattern, or mopped with Type III or IV asphalt.

Maximum asphalt application temperatures of 425°F (218°C) to 450°F (232°C) are recommended. Application temperatures above these recommended temperatures may adversely affect roof system performance.

Edge joints should be located on and parallel to deck ribs. End joints of adjacent lengths should be staggered.

1. This material shall be installed with ends and edges butted tightly.

2. When installed over combustible wood decks or insulations, all joints should be staggered.

3. In accordance with approved shop drawings, FM Approved fasteners shall be installed with plates through the roof board, flush with the surface.

Review Carlisle specifications and details for complete installation information.

Precautions

» Dens Deck is not suitable for adhered membrane roofing systems

» Panels must be kept dry before, during and after installation. Apply only as much roof board as can be covered by roof membrane in the same day.

» ¼" DensDeck is not recommended for vertical parapet applications.

» In ballasted roofing systems, DensDeck is not an acceptable membrane underlayment.

» ¼" DensDeck is not recommended for use with Type III and Type IV asphalt.

Ratings and Certifications

» Manufactured to conform to ASTM C-1177

» Tested in accordance with ASTM E-84 or CAN/ULC-S102

» Non-combustible when tested in accordance with ASTM E-136

» UL code approval for current class A, B, C approvals

DensDeck

Roof Board Coverboard

Highlight

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

05.04.23 © 2023 Carlisle.

REPRINT CODE: 601486 INS_CST-6042 - “DensDeck Roof Board Product Data Sheet”

Carlisle and FAST are trademarks of Carlisle. DensDeck is a registered trademark of Georgia-Pacific Gypsum LLC.

Typical Properties and Characteristics

Properties ¼" (6.4 mm) ½" (12.7 mm) 5⁄8" (15.9 mm)

Thickness, nominal ¼" (6.4 mm) ± 1⁄16" (1.6 mm) 1/2" (12.7 mm) ± 1⁄32" (.8 mm) 5/8" (15.9 mm) ± 1⁄32" (.8 mm)

Width, standard 4' (1219 mm) ± 1⁄8" (3 mm) 4' (1219 mm) ± 1⁄8" (3 mm) 4' (1219 mm) ± 1⁄8" (3 mm)

Length, standard 8' (2438 mm) ± ¼" (6.4 mm) 8' (2438 mm) ± ¼" (6.4 mm) 8' (2438 mm) ± ¼" (6.4 mm)

Weight, nominal, lbs./sq. ft. (Kg/m²)7 1.2 (5.9) 2.0 (9.8) 2.5 (12.2)

Surfacing Fiberglass mat Fiberglass mat Fiberglass mat

Flexural Strength1, parallel, lbf. min. (N) ≥40 (178) ≥80 (356) ≥100 (444)

Flute Spanability 2 25⁄8" (67 mm) 5" (127 mm) 8" (203 mm)

Permeance3, Perms (ng/Pa• S• m²) >50 (2850) >35 (1995) > 32 (1824)

R Value4, ft²• °F• hr/BTU (m²• K/ W) 0.28 0.56 0.67

Linear Variation with Change in Temp., in/in °F (mm/mm/C°) 8.5 x 10-6 (15.3 x 10-6) 8.5 x 10-6 (15.3 x 10-6) 8.5 x 10-6 (15.3 x 10-6)

Linear Variation with Change in Moisture 6.25 x 10-6 6.25 x 10-6 6.25 x 10-6

Water Absorption5, % 5 5 5

Compressive Strength6, psi nominal 900 900 900

Surface Water Absorption, grams, nominal1 1.0 1.0 1.0

Flame Spread, Smoke Developed (ASTM E84) 0/0 0/0 0/0

Bending Radius 5' (1524 mm) 8' (2438 mm) 12' (3658 mm)

1 Tested in accordance with ASTM C473 method B.

2 Tested in accordance with ASTM E661.

3 Tested in accordance with ASTM E96 (dry cup method).

4 Tested in accordance with ASTM C518 (heat flow meter).

5 Tested in accordance with ASTM C1177.

6 Tested in accordance with ASTM C473.

7 �Represents approximate weight for design and shipping purposes. Actual weight may vary based on manufacturing location and other factors.

DensDeck Roof Board

LEED® Information

Manufacturing Location1

Total Recycled Content2

Pre-Consumer Recycled Content2

Post-Consumer Recycled Content2

Acme, TX 0% 0% 0%

Antioch, CA 0% 0% 0%

Ft. Dodge, IA 0% 0% 0%

Las Vegas, NV 0% 0% 0%

Lovell, WY 0% 0% 0%

Newington, NH 30% 30% 0%

Savannah, GA 0% 0% 0%

Tacoma, WA 14% 14% 0%

Wheatfield, IN 94% 94% 0%

1 �Manufacturing locations subject to change. Please visit www.gpgypsum.com and click on Sustainability.

2 Recycled content subject to change +/– 1.0%.

3 �Based on ICC Evaluation Service Verification of Attributes Report for Dens® brand products issued August 1, 2009. www.saveprogram.icc-es.org

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Overview

InsulBase is a rigid-roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to glass-reinforced felt (GRF). ReadyFlash® Technology is a standard feature of InsulBase Polyiso that allows the contractor to manipulate flash-off times by choosing which side of the insulation board to apply membrane adhesives. ReadyFlash features a dark glass-reinforced felt (GRF) on one side of the insulation board and a light glass-reinforced felt on the other.

» Increases surface temperature of the dark facer up to 25ºF above ambient temperature and provides up to 30% faster adhesive flash-off.

» Decreases surface temperature of the light facer up to 5ºF below ambient temperature.

Features and Benefits

» InsulBase polyiso insulation provides the highest R-value per inch of commercially available insulation products

» Zero ozone-depleting components, HFC- and HCFC-free formulation

» Approved for direct application to steel decks

Panel Characteristics

» Available in 4' x 4' (1220 mm x 1220 mm) and 4' x 8' (1220 mm x 2440 mm) panels in thickness of ½" (13 mm) to 4.5" (115 mm)

» Available in 4' x 12' (1220 mm x 3660 mm) panels in the following thickness: 1.5", 1.75", 2.0", 2.2", 2.5", 2.6", 3.0", 3.3", and 3.5"

Applications

» Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered)

Sustainable Attributes

Carlisle SynTec Systems’ focus has always been innovation – Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Carlisle is committed to driving sustainable and efficient processes in the design and manufacturing of our products.

» Zero ozone-depleting components, HFC- and HCFC-free formulation

» CDPH Compliant for maximum allowable concentrations of target VOCs

» Up to 56.9% recycled content by weight (36.6% post-consumer/20.3% pre-consumer)

» Contributes to LEED® and Green Globes certification requirements

» End-of-life jobsite disposal options available for re-use/re-purposing

» Carlisle Polyiso Roof Insulation and HD Cover Board EPDs available

» PIMA Quality MarkCM Certification Program participant for Long-Term Thermal R-values (LTTR)

» Highest R-value per inch providing maximum energy savings and CO2 emissions avoidance

Polyiso Eco Ready (Optional)

» 5% bio-content option available (for 2.0" and 2.6" thicknesses)

» Contributes to carbon reduction initiatives via mass balance approach under ISCC PLUS compliance

Installation

Ballasted Single-Ply Systems Each InsulBase panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifications.

Mechanically Attached Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifications.

Fully Adhered Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifications.

InsulBase 4' x 8' and 4' x 12' panels can be secured to the roof deck with Carlisle’s Flexible FAST® Adhesive, either full coverage or bead spacing.

InsulBase 4' x 4' panels may be adhered to prepared concrete deck with a full mopping of Type III or IV asphalt.

Review Carlisle specifications and details for complete installation information.

E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E daileylo Rectangle

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

02.19.25 © 2025 Carlisle.

REPRINT CODE: 600491 INS_CST-2129 - “InsulBase Polyiso Product Data Sheet”

US PATENT NUMBER: 10,662,652

Carlisle, InsulBase, ReadyFlash, and FAST are trademarks of Carlisle.

Codes and Compliances

» ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi)

» International Building Code (IBC) Section 2603

» UL Standard 790, 263 and 1256: Component of Class A Roof Systems (refer to UL Roof Materials’ system directory)

» FM® Standards 4450/4470: Class 1 approval for steel roof-deck constructions (refer to FM RoofNavSM)

» California Code of Regulations, Title 24, Insulation Quality Standard License #TI-1418

» Third-party certification with the PIMA Quality Mark for Long-Term Thermal Resistance (LTTR) values

» CAN/ULC S704, Type 2, Class 3 (20PSI), Type 3, Class 3 (25PSI)

» Florida Building Code Approval

» CDPH compliant for maximum allowable concentrations of target VOCs

Precautions

Insulation must be protected from open flame and kept dry at all times.

Install only as much insulation as can be covered the same day by completed roof-covering material. Protect installed product from excessive foot traffic. Carlisle will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the jobsite or for improper storage and handling.

Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specific details, or refer to PIMA Technical Bulletin No.

109: Storage & Handling Recommendations for Polyiso Roof Insulation.

Typical Properties and Characteristics

(ASTM C1289)

Physical Property Test Method Value

Compressive Strength ASTM D1621 20 psi* minimum (138 kPa, Grade 2)

Dimensional Stability ASTM D2126 2% linear change (7 days)

Moisture Vapor Permeance ASTM E96 <1 perm (57.5 ng/(Pa•s•m²))

Water Absorption C1763 <1% volume

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.

*Also available in 25 psi minimum, Grade 3

Foamed plastic as roof deck construction material with resistance to an internal fire exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certified for Canada and UL Roofing Materials and Systems Directory. 99DL.

InsulBase Polyiso Thermal Values

Thickness (inches) LTTR R-value Thickness

(inches) LTTR R-value

0.5 2.8 2.75 15.9

0.75 4.2 2.8 16.2

1 5.7 2.9 16.8

1.1 6.3 *3.0 17.4

1.2 6.8 3.1 18.0

1.25 7.1 3.2 18.6

1.3 7.4 3.25 18.9

1.4 8.0 *3.3 19.2

*1.5 8.6 3.4 19.9

1.6 9.1 *3.5 20.5

1.7 9.7 3.6 21.1

*1.75 10.0 3.7 21.7

1.8 10.3 3.75 22.0

1.9 10.8 3.8 22.3

*2 11.4 3.9 23.0

2.1 12.0 4 23.6

*2.2 12.6 4.1 24.2

2.25 12.9 4.2 24.9

2.3 13.2 4.25 25.2

2.4 13.8 4.3 25.5

*2.5 14.4 4.4 26.1

*2.6 15.0 4.5 26.8

2.7 15.6 . .

Flute Spanability is 25⁄8" for 1.4" or thickness or smaller. Flute Spanability is 43⁄8" for 1.5" thickness or greater.

*4' x 12' offering is available in this thickness.

daileylo Rectangle

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Overview

Carlisle’s VapAir Seal 725TR Air and Vapor Barrier/Temporary Roof is a 40-mil composite consisting of 35 mils of self-adhering rubberized asphalt laminated to a 5-mil woven polypropylene film. A one-piece silicone poly release liner is applied to the SBS adhesive to prevent the material from bonding to itself. VapAir Seal 725TR is available in a 325-square-foot roll with dimensions of 39" x 100'. The factory-controlled thickness of the membrane ensures uniform barrier properties on the job; the woven polypropylene film increases strength and has a non-skid surface suitable for the bonding of subsequent layers. Approved Carlisle adhesives for attaching insulation to VapAir Seal 725TR are:

» Flexible FAST™ Adhesive

» OlyBond 500™

VapAir Seal 725TR can be used on concrete, plywood, exterior gypsum, DensDeck® Prime, SECUROCK® or other approved substrates in conjunction with Carlisle SynTec roofing systems. Gypsum decks may require additional securement with mechanical fasteners. Use of CAV-GRIP™ III Low-VOC Adhesive/Primer, CCW-702 or CCW-702LV is required on all substrates.

VapAir Seal 725TR may be installed directly over a nailed Carlisle Modified Base Sheet when primed with CAV-GRIP III.

VapAir Seal 725TR must be covered with roofing membrane within 120 days. T-joints must be sealed with an internal bead of Carlisle Lap Sealant.

Carlisle does not accept responsibility for the watertight integrity of the VapAir Seal 725TR related to workmanship issues or physical damage.

For unusual situations, contact the Project Review and Warranty Services Department prior to specifying this material.

Installation

Surface Preparation: The concrete surface shall be completely dry;

dryness shall be determined by a qualified owner’s representative. The surface shall have a smooth finish and be free of voids, spalled areas, sharp protrusions, loose aggregate, laitance and form-release agents.

Some curing compounds may interfere with proper adhesion, so an adhesion test is recommended. In the event of rain, concrete must be allowed to dry before the application of primer. Artificial drying methods such as torches are not acceptable.

Adhesive: Surfaces to receive VapAir Seal 725TR must be clean and dry. Use of CAV-GRIP III, CCW-702 or CCW-702LV is required on all substrates. Approved Carlisle adhesives for attaching insulation to VapAir Seal 725TR are: Flexible FAST Adhesive and OlyBond 500.

Application: VapAir Seal 725TR material must be stored and kept above 60°F prior to installation. Apply VapAir Seal 725TR from low to high points in a shingle fashion so that the laps will shed water.

Overlap all edges by at least 2". End laps should be staggered. Position the membrane carefully to avoid fish-mouths and wrinkles. Roll the VapAir Seal 725TR membrane immediately after installation with a 100 – 150-pound roller wrapped in a resilient material. When the VapAir Seal 725TR is applied to a vertical surface, hand-rolling with a 2" or 4" hand roller is required. Vertical surfaces must be prepared in the same fashion as horizontal surfaces.

Note: For applications below 40°F – all materials must be kept above 60°F prior to installation and CAV-GRIP III Primer must be used.

Seaming: Apply a 2"-long bead of lap sealant internally along any T-joints or step-offs. Use a hand roller or stand-up seam roller to mate the entire seam together, ensuring the seam’s leading edge is rolled properly.

Be sure to pay particular attention to the T-joints and step-offs. If seam surface is contaminated, clean and prime with CCW-702, CCW-702LV, or

CAV-GRIP III.

Review Carlisle specifications and details for complete installation information.

Air and Vapor Barrier/Temporary Roof

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

10.20.21 © 2021 Carlisle.

REPRINT CODE: 603967 FB-1020 - “Carlisle VapAir Seal 725TR Product Data Sheet”

Carlisle, CAV-GRIP, and FAST are trademarks of Carlisle. OlyBond 500 is a trademark of OMG Roofing Products.

SECUROCK is a registered trademark of USG Corporation. DensDeck Prime is a trademark of G-P Gypsum Corporation.

LEED is a registered trademark of the U.S. Green Building Council.

Precautions

» Use proper stacking procedures to ensure sufficient stability of the materials.

» Exercise caution when walking on wet membrane. Membranes are slippery when wet.

» VapAir Seal 725TR must be clean and dry prior to installation of subsequent layers.

» VapAir Seal 725TR should be installed using CAV-GRIP III adhesive when temperatures are below 40°F.

» VapAir Seal 725TR membrane and primers must be stored above 60°F prior to installation.

» Avoid moving or stacking heavy loads on the installed membrane, particularly in hot weather. This could thin out the self-adhering barrier layer.

» Refer to applicable Safety Data Sheets before using any Carlisle products.

» Do not apply CAV-GRIP III, CCW-702 or membrane to damp or contaminated surfaces.

» Do not apply CAV-GRIP III, CCW-702 or membrane to frozen substrates.

» Primers must be allowed to completely flash off. Refer to the primer PDS for flash-off times.

LEED® Information

Pre-consumer Recycled Content 0%

Post-consumer Recycled Content 0%

Manufacturing Location Terrell, TX

VOC Content 0 g/L

Solar Reflectance Index N/A

Packaging

Product 725TR Air & Vapor Barrier/Temporary Roof

Size/Weight 39" x 100' / 89 lbs

Actual Coverage Rate 305 ft2

Part Number 330170

Typical Properties and Characteristics

Physical Property Test Method Typical

Thickness ASTM D1970 40 mils

Tensile Strength ASTM D412 250 psi

Elongation ASTM D412 250%

Peel Adhesion ASTM D903 5 lbs/in

Puncture Resistance ASTM E154 60 lbs

Permeability ASTM D1970* 0.015 perms

Air Permeance ASTM E2178 0.000 L*m2 @ 75 Pa

Shelf Life N/A 1 year

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.

*D1970 is tested to E96 standards for permeability.

Air and Vapor Barrier/Temporary Roof

Product Data

FASTENERS & PLATES

Carlisle SynTec Systems offers an array of fasteners and plates to complement our roofing systems. From pre-assembled choices for EPDM installations to Purlin fasteners for Metal Retrofit Systems and Piranha plates for Sure-Weld® options, our mission continues to be to provide all components necessary for the application of a long-lasting and secure single-ply roofing system from Carlisle.

Applicable to steel, 22-gauge and heavier, CDX plywood and wood plank deck types. Can be used to secure Sure-Tough membranes, RUSS and insulation. Longer fastener sizes available as special order.

Sizes Available:

1¼", 2"– 15" (1" Increments)

Size & Quantity Per Box:

2"– 6": 1,000; 7"– 12": 500; 13"– 15": 250 1¼":1000

A #12 diameter fastener applicable to wood decks and steel, 22-gauge and heavier, decks.

Used only for insulation attachment.

Sizes Available:

2"– 8" (1" Increments) 1⅝", 2¼", 3"– 8" (1" Increments)

Size & Quantity Per Box:

2"– 8": 1,000

HP FASTENER

INSULFAST™

A 0.33" diameter fastener applicable to steel, 22-gauge and heavier. Can be used for Sure- Tough membrane securement in mechanically attached systems.

Sizes Available:

2"– 8" (1" Increments)

Size & Quantity Per Box:

2", 3": 500; 4"– 8": 250

Applicable to cementitious wood fi ber, lightweight concrete and gypsum decks. Can be used to secure Sure-Tough, Sure-Weld and Sure-Flex membranes and insulation.

Sizes Available:

2½"– 10" (½" Increments)

Size & Quantity Per Box:

2½"– 7": 500; 7½"– 10": 250

GYPTEC PLATE

Sizes Available:

2" Metal membrane plate 3" Metal insulation plate

Quantity Per Box: 1,000

A #14 diameter fastener used for Sure-Tough, Sure-Weld and Sure-Flex membrane securement into wood and concrete decks. Also applicable to insulation securement into steel, wood and concrete decks.

Sizes Available:

2"– 12" (1" Increments) 14"– 24" (2" Increments)

Size & Quantity Per Box:

2"– 4": 1,000; 5"– 11": 500; 12"– 24": 250

A #15 diameter fastener applicable to steel, wood and CDX plywood. Can be used to secure Sure-Seal, Sure-Weld and Sure-Flex membranes.

Sizes Available:

2"– 8" (1" Increments) 10"– 16" (2" Increments)

Size & Quantity Per Box:

2"– 4": 1,000; 5"– 12": 500; 14"– 16": 250

HP-XTRA FASTENER

Also Available (Not shown) A #21 diameter fastener applicable to steel, wood and CDX plywood decks.

Sizes Available:

2" – 8" (1" increments)

Size & Quantity Per Box:

500 (2" – 6"), 250 (7" – 8")

SURE-TITE®

GYPTEC FASTENER & PLATE

HD 14-10

HP-X FASTENER™ & HP-XTRA FASTENER

Applicable for concrete decks. Used to secure Sure-Seal, Sure-Weld and Sure-Flex membranes and for insulation securement.

Sizes Available:

2"– 6" (½" Increments) 7"– 12" (1" Increments)

Size & Quantity Per Box:

2"– 8": 500; 9"– 12": 250

CD-10

Sure-Seal® & Sure-White® EPDM

Sure-Weld TPO

Sure-Flex™ PVC

Experience the Carlisle Difference 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com daileylo Rectangle

Product Data

Experience the Carlisle Difference 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, Sure-Seal, Sure-Weld, FleeceBACK, Sure-Flex, Sure-White, HP-X Fastener, InsulFAST, Sure-Tite and RUSS are trademarks of Carlisle.

RhinoBond is a registered trademark of OMG, Inc.

REPRINT REQUEST CODE: 600269 - Fasteners & Plates Product Data Sheet - 02.19.13 © 2013 Carlisle.

FASTENERS & PLATES

A pre-assembled #12 diameter fastener and plastic insulation plate applicable to steel and wood decks. Used to secure insulation only.

Longer fastener sizes available as special order.

Sizes Available:

2¼", 3"– 12" (1" Increments)

Size & Quantity Per Box:

2¼"– 8": 250; 9"– 12": 200

Pre-assembled HP Fastener and Polymer seam plate applicable to steel, wood and CDX plywood decks. Used to secure Sure-Tough membranes.

Sizes Available:

2¼", 3"– 12" (1" Increments)

Size & Quantity Per Box:

2¼", 3", 3¼", 3¾": 450; 4", 5": 400; 6": 350;

7", 8": 300; 9": 250; 10"– 12": 200

Along with the appropriate fastener, used to secure Sure-Weld and Sure-Flex membranes to steel, concrete and wood decks.

Sizes Available:

2 3/8" diameter

Quantity Per Box: 1,000

HP-XTRA PIRANHA PLATE

Also Available (Not shown) For use with HP-XTRA Fastener to secure Sure-Weld and Sure-Flex membranes to steel and wood decks.

Sizes Available:

2 3/8" diameter Quantity Per Box: 1,000

Applicable with HP, HD 14-10 and CD-10 fasteners to mechanically attach reinforced Sure-Tough membrane (excluding steel decks) and RUSS (except when used with mechanically fastened EPDM to steel decks).

Sizes Available:

2" diameter

Quantity Per Box: 1,000

A pre-assembled HP-X Fastener and Piranha Plate™ applicable to steel, wood and CDX plywood decks. Used to secure Sure-Weld and Sure-Flex membranes.

Sizes Available:

2"–10" (1" Increments) 12"–16" (2" Increments)

Size & Quantity Per Box:

2"– 9": 250; 10"– 12": 200; 14"– 16": 150

Along with the HP Fastener, used to mechanically fasten reinforced Sure-Tough membrane and RUSS over steel decks.

Sizes Available:

2" diameter

Quantity Per Box: 1,000

HP-XTRA POLYMER SEAM PLATE

Also Available (Not shown) For use with HP-XTRA Fastener to secure Sure-Tough membranes to steel decks.

Sizes Available:

2 3/8" diameter Quantity Per Box: 1,000

Applicable with InsulFast, HP, CD-10 and HD 14-10 fasteners. Used for insulation securement only on steel, wood and concrete decks.

Sizes Available:

3" diameter

Quantity Per Box: 1,000

ASAP WITH POLYMER PLATE

HP PRE-ASSEMBLED

PIRANHA PLATE

SEAM FASTENING PLATE

HP-X ASAP

HP POLYMER SEAM PLATE

INSULATION FASTENING PLATE

3"-round, specially coated plates used with HP-X Fasteners and the RhinoBond induction welding system. Available in TPO and PVC versions.

Sizes Available:

3" diameter Quantity Per Box: 500/carton

RHINOBOND® PLATE

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Low-VOC Bonding Adhesive

Overview

Sure-Flex PVC Low-VOC Bonding Adhesive is a high-strength solvent-based contact adhesive that allows bonding of PVC and KEE membranes to various porous and non-porous substrates. It is specially formulated using a blend of VOC-exempt and non-exempt solvents to be in compliance with the state of California Clean Air Act of 1988 (updated in 1997) and as further regulated by California’s Air Quality Control Districts listing VOC limitations. This product also meets the <250 gpl VOC content requirements of the OTC Model Rule for Single-Ply Roofing Adhesives.

Features and Benefits

» High-strength adhesive that allows quick bonding

» Can be easily applied with a medium nap roller

» Provides excellent adhesion between various substrates and PVC and/or KEE membranes

Coverage Rate

60 ft² (5.6 m²) per gallon finished surface. Coverage rates are average and may vary due to conditions on the jobsite. Porous surfaces and substrates may require more bonding adhesive than the typical coverage rate.

Mixing

Stir thoroughly until the adhesive is uniform in color. Minimum 5 minutes stirring is recommended.

Application

1. The surface on or against which adhesive is to be applied shall be clean, smooth, dry, free of fins, sharp edges, loose and foreign materials, oil and grease. Depressions greater than ¼" (6 mm) should be feathered using epoxy, mortar or other approved patching material. All sharp projections shall be removed by sweeping, blowing or vacuum cleaning.

2. After thorough stirring (minimum 5 minutes), apply PVC Low-VOC Bonding Adhesive to substrate and membrane using a 9" (229 mm) medium nap roller. Application shall be continuous and uniform, avoiding globs or puddles. Once flashed off, adhesive will have little to no tackiness and provides an application window of roughly 15- 20 minutes depending upon ambient temperature. Any coated area that has been exposed to rain should be allowed to dry and then recoated. Do not apply adhesive to splice areas to be hot-air welded.

3. Roll the membrane onto the adhesive-coated substrate while avoiding wrinkles. Immediately brush down the bonded portion of the sheet with a soft-bristle push broom or a clean dry roller applicator to achieve maximum contact.

Review Carlisle specifications and details for complete application information.

Precautions

» Review the applicable Material Safety Data Sheet for complete safety information prior to use.

» PVC Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE. It contains solvents that are dangerous fire and explosion hazards when exposed to heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground or may be moved by ventilation and ignited by pilot lights, other flames, sparks, heaters, smoking, electrical motors, static discharge, or other ignition sources at locations distant from material handling point. All containers should be grounded when material is transferred from one container to another. A red caution label is required when shipping. A fire extinguisher should be available. In case of fire, use water spray, foam, dry chemical or carbon dioxide. Do not use a solid stream of water because it can scatter and spread the fire.

» Avoid breathing vapors. Keep container closed when not in use.

Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh air intake units. When possible, shut down or seal off the closest units.

Flashing Adhesive

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

07.14.22 © 2022 Carlisle.

REPRINT CODE: 605666 PVC-2192 - “Sure-Flex PVC Low-VOC Bonding Adhesive Product Data Sheet”

Carlisle and Sure-Flex are trademarks of Carlisle.

LEED is a registered trademark of the U.S. Green Building Council.

» If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately.

» Avoid contact with eyes. Safety glasses or goggles are recommended.

If splashed in eyes, immediately flush eyes with plenty of clean water for at least 15 minutes. Contact a physician immediately.

» Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Contact physician if irritation persists.

Note: Permeation-resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be worn when using this product to protect hands from irritating ingredients.

» Do not thin PVC Low-VOC Bonding Adhesive. Thinning will affect performance. Excessively thick or gelled material should be discarded.

» Jobsite storage in excess of 90°F (32°C) may affect product shelf life.

Should the PVC Low-VOC Bonding Adhesive be stored at temperatures lower than 60°F (15°C), restore to room temperature prior to use.

» Opened containers of PVC Low-VOC Bonding Adhesive should be used within 48 hours. Adhesives will begin to thicken after this point, making it difficult and eventually impossible to control applied thickness. In hot weather, do not leave sealed containers on roof for prolonged periods of time. In cold weather, keep material at room temperature until ready to use. Stir adhesive occasionally while using.

» Adhesive must be allowed to dry thoroughly. If membrane is mated with the substrate prior to the adhesive being dry, blistering will occur and will not subside over time.

» KEEP OUT OF REACH OF CHILDREN.

Typical Properties and Characteristics

Base Synthetic rubber

Color Pale yellow to orange to amber

Solids 23.6 –29.6%

Flash Point -4°F (-20°C) SETA

Brookfield Viscosity 1500 – 4500 centipoises

Average Net Weight 6.9 – 7.7 lbs/gal (0.8 – 0.9 kg/l)

Packaging 5-gal pail

Shelf Life 1 year

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.

LEED® Information

Pre-consumer Recycled Content 0%

Post-consumer Recycled Content 0%

VOC Content <250 g/l

Manufacturing Location Carlisle, PA

Low-VOC Bonding Adhesive

Non-Reinforced Flashing

Overview

Carlisle’s Sure-Flex PVC Non-Reinforced Flashing is a 60-mil thermoplastic polyvinyl chloride (PVC) membrane. Available in white, gray, and tan, PVC Flashing is offered in 12" and 24" by 50' rolls. When the use of prefabricated accessories is not feasible, PVC Flashing can be used to create inside and outside corners, fi eld-fabricated pipe fl ashings, curb corners, and scuppers.

Features and Benefi ts

» KEE HP enhances fl exibility, making it easier to fi eld-fabricate details

» KEE HP increases weatherability for added protection at critical transition areas and maximum longevity

» Superior weldability allows for consistent, high-quality seams in penetrations and other critical roof areas

» Available in white, gray, tan, light gray, and slate gray to match Carlisle’s Sure-Flex PVC and KEE HP membranes

» Non-reinforced PVC enhanced with KEE HP for superior performance

» Can be used on both PVC and KEE HP systems

Installation

1. PVC Flashing is used to fl ash various roofi ng system details and penetrations. The specifi c installation method will vary based on the situation.

2. Use a lower temperature setting on the heat welder than when welding non-reinforced PVC membrane. Typically, a setting of 7 on a scale of 10 is appropriate for welding PVC Flashing.

3. Use the edge of the roller to crease the fl ashing into any membrane step-offs for a proper seal.

Review Carlisle specifi cations and details for complete installation information.

Precautions

» Review the applicable Safety Data Sheet for complete safety information prior to use.

» Sunglasses that fi lter out ultraviolet light are strongly recommended, as white surfaces are highly refl ective. Roofi ng technicians should dress appropriately and wear sunscreen.

» Store PVC Flashing in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. PVC Flashing that has been exposed to the weather for approximately 7 days or longer must be prepared with PVC Membrane Cleaner prior to hot-air welding.

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

11.06.20 © 2020 Carlisle.

REPRINT CODE: 600319 - “Sure-Flex PVC Non-Reinforced Flashing Product Data Sheet”

Carlisle and Sure-Flex are trademarks of Carlisle.

LEED is a registered trademark of the U.S. Green Building Council.

Typical Properties and Characteristics

Properties ASTM Test Method Specifi cation

Tolerance on nominal Thickness ASTM D751 ±8

Weight, lb/ft² (kg/m²), typical 0.44 lb/ft²

Breaking strength, min, lbf/in. (N) ASTM D751 Proc. B 167.60 (MD),

142.88 (CD)

Elongation at Break, min., % ASTM D751 Proc. B 399.60 (MD),

420.27 (CD)

Tear strength, min., lbf/in (kN/m) ASTM D1004 10

Heat aging: 28 days % Retention ASTM D4434 90

Resistance to Xenon-Arc weathering

- Xenon-Arc, 5,040 kJ/m2 total radiant

- Exposure, visual condition at 7X

ASTM D4434 "No cracking/ crazing, negligible discoloration”

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product.

LEED® Information

Pre-consumer Recycled Content 10%

Post-consumer Recycled Content 0%

Manufacturing Location Mountain Top, PA

Solar Refl ectance Index 111 (white), 69 (gray), 81 (tan), 90 (light gray), N/A (slate gray)

Inside Corners

Overview

Sure-Flex PVC Inside Corners are pre-molded and are used for flashing the inside corners on a variety of details. Installation is fast and easy with no cutting or stretching required. This product is available in white, gray and tan.

Carlisle’s PVC Inside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory-fabricated PVC accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system.

Features and Benefits

» Forms easily into out-of-square corners that are not exactly 90 degrees

» Provides substantial labor savings compared to field-fabricating the flashing detail from non-reinforced flashing

» More consistent appearance than inside corners field-fabricated from flashing

» Non-reinforced PVC enhanced with KEE HP for superior performance

» Can be used on both PVC and KEE HP systems

Installation

1. Position the PVC Inside Corner into the corner, begin welding at the innermost corner point and work away from the corner.

2. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal.

3. Probe all welded edges of the corner once the material has been completely cooled to ensure watertight performance.

Review Carlisle specifications and details for complete installation information.

Precautions

» Store PVC Inside Corners in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. PVC Inside Corners or PVC membranes that have been exposed to the weather or contaminated with dirt must be prepared with PVC Membrane Cleaner prior to hot-air welding.

Typical Properties and Characteristics

Thickness .060" (1.52 mm)

Packaging 12/bag

Material Injection-molded non-reinforced KEE HP enhanced PVC flashing

Color White, Gray and Tan

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

10.28.20 © 2020 Carlisle.

REPRINT CODE: 605148 PVC-1008 - “Sure-Flex PVC Inside Corners Product Data Sheet”

Carlisle and Sure-Flex are trademarks of Carlisle.

LEED is a registered trademark of the U.S. Green Building Council.

LEED® Information

Pre-consumer Recycled Content 0%

Post-consumer Recycled Content 0%

Manufacturing Location Bloomingdale, IL

Solar Reflectance Index (SRI) White: 111 Gray: 43 Tan: 50

Outside Corners

Overview

Sure-Flex PVC Outside Corners are pre-molded and are used for flashing outside corners on a variety of details. Installation is fast and easy with no cutting or stretching required. This product is available in white, gray and tan.

Carlisle’s PVC Outside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory-fabricated PVC accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system.

Features and Benefits

» Pre-formed, multi-wave design allows wrapping outside corners that are out of square and not exactly 90 degrees

» Provide substantial labor savings compared to field-fabricating the flashing detail from non-reinforced flashing

» More consistent appearance than outside corners field-fabricated from flashing

» Non-reinforced PVC enhanced with KEE HP for superior performance

» Can be used on both PVC and KEE HP systems

Installation

1. Position the PVC Outside Corner and begin welding at the innermost corner point and work away from the corner.

2. Use the edge of the roller to crease the corner flashing into any membrane step-off for a proper seal.

3. Probe all welded edges of the corner once the material has been completely cooled to ensure watertight performance.

Review Carlisle specifications and details for complete installation information.

Precautions

» Store pre-molded corners in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. PVC Outside Corners or PVC membranes that have been exposed to the weather or contaminated with dirt must be prepared with PVC Membrane Cleaner prior to hot-air welding.

Typical Properties and Characteristics

Thickness 0.060" (1.52 mm)

Packaging 12 /bag

Material Injection-molded non-reinforced KEE HP enhanced PVC flashing

Color White, gray and tan

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

11.03.20 © 2020 Carlisle.

REPRINT CODE: 605151 PVC-1009 - “Sure-Flex PVC Outside Corners Product Data Sheet”

Carlisle and Sure-Flex are trademarks of Carlisle.

LEED is a registered trademark of the U.S. Green Building Council.

LEED® Information

Pre-consumer Recycled Content 0%

Post-consumer Recycled Content 0%

Manufacturing Location Bloomingdale, IL

Solar Reflectance Index (SRI) White: 111 Gray: 43

800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com

Overview

Carlisle’s Sure-Flex PVC Pipe Seals are injection-molded, pre-formed flashings for pipes .75" (19 mm) to 8" (203 mm) in diameter. This labor-saving accessory provides a quick and reliable way to waterproof round pipe penetrations.

Sure-Flex PVC Pipe Seals are part of Carlisle’s Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory-fabricated PVC accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system.

Features and Benefits

» Provides a reliable method of waterproofing round pipe penetrations

» Provides substantial labor savings compared to field-fabricating from non-reinforced flashing

» Provides a more consistent appearance than field-fabricated pipe flashings

» Double-ribbed cutting guide facilitates easier, smoother, and straighter cuts

» Rib design holds the clamp in the proper position

» Non-reinforced PVC enhanced with KEE HP for superior performance

» Can be used on both PVC and KEE HP systems

Molded Pipe Flashing

Installation

1. Cut Pipe Seal between double-ribbed cutting guides, one size smaller than the pipe diameter. Do not cut off raised ring.

2. Pull Pipe Seal over pipe until base flange is in contact with the membrane. It may be necessary to apply heat to the top portion of the Pipe Seal to allow installation over the pipe.

3. Mark pipe around the top of the Pipe Seal.

4. Pull Pipe Seal upwards on pipe until mark on the pipe is visible.

5. Apply Universal Single-Ply Sealant below the mark that indicates the top of the installed Pipe Seal.

6. Pull Pipe Seal back down over pipe and into position.

7. Heat-weld the Pipe Seal base flange to deck membrane.

8. Install a stainless steel universal clamping ring to provide constant compression of the sealant.

Review Carlisle specifications and details for complete installation information.

Precautions

» Remove all lead and other flashing.

» Temperature of pipe must not exceed 140°F (60°C).

» Install a minimum of four fastening plates around pipe penetrations.

Position fastening plates around the penetration so they are covered by the Pipe Seal flange. A minimum 1.5"-wide weld must be maintained around the outer edge of the flange beyond the plates. If fastening plates cannot be installed in a manner to allow a minimum 1.5" weld, the plates must be placed outside the Pipe Seal flange and covered with a reinforced Sure-Flex membrane overlay.

» Store Pipe Seals in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Sure-Flex Pipe Seals or membranes that have been exposed to the weather must be prepared with PVC Membrane Cleaner prior to hot-air welding.

Typical Properties and Characteristics

Sizes 3/4" to 8" O.D. Pipe (19 to 203 mm)

Packaging 8 per box

Weight (each) 0.55 lbs (0.25 kg)

Material Injection molded non-reinforced KEE HP enhanced PVC flashing

Color White, Tan, Gray, and Light Gray

Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.

This is the start of the file's text. The full file is on GovTribe.