B95_Salem_Armory Existing_PS.pdf
PDF 290 KB Posted
- Attached to
- SALEM AREA FACILITIES LOCKER UPGRADES
- Solicitation number
- S-24800-00003700
- Issued by
- Marion County, Oregon
About this file
The document is a set of plans for the existing lockers at the B95 Salem Armory facility, which is part of a larger state and local contract opportunity called the "SALEM AREA FACILITIES LOCKER UPGRADES" project. The project is being conducted by the Oregon Military Department and involves upgrading the lockers at the Salem Armory. The plans detail the existing locker configuration, including the number and size of lockers and cages. The related state and local contract opportunity covers the labor, materials, transportation, equipment, and services required to complete the construction work for the locker upgrades project.
The contract opportunity is open to bidders in the jurisdictions of Marion County and the City of Salem. The anticipated scope of work includes all construction activities necessary to upgrade the lockers at the facility. The solicitation does not provide specific details on pricing terms, set asides, incumbent contractors, funding requirements, or contract duration and renewal options.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTENANCE
STORAGE & VAULTS
821 CONFERENCE
1186 LOCKERS
SIP
Rn etKITCHEN-
821 MAIL RM 821
OFFICE
821 BNCDR
821 CSM
821 XO/AO
S3 OPS (821)
MECHANICAL
SMW
OFF
ICE
S
STATE
SERVICE AREA
CO
PY
RO
OM
11 12 14 15 16
31 30 29
26A
23A 23
23B 23C 23D
15A
15B
12345
10A 10
B95 SALEM ARMORY
BO
ILE
R
ID
F
EDIT: 16 June 2022 CRT
CA
GE
S
PUMPSBO
ILE
R
STORAGE
LOCKER ROOM
12. HHD 821
SUPPLY &
115 PAD CAGES
HHD 821
S3 OPS (821)
821 S4
821 S1
821 S1
821 FSGRECRUITING
ETTE
CLASSROOM
CD
R/
1S G
SELECTIVE
SERVICE
FU
NE
RA
L
HO
NO
RS
HHD ORDERLY
HHD RNCO
HHD 1SG
HHD CDR
& ADMIN
AREA
115 STORAGE
FITNESS ROOM
VA
UL
T
SUPPLY
HHD 821
SH
OW
ER
M
EN
'S
R /R
WAS
HR/
DRY
ER
W
OM
EN
'S
R/ R
SH
W R
JAN
ITO
R
CL
OSE
T
S
TO
RA
GE
C
AG
ES
a
ROOM MAIN
SWITCH GEAR
12a ELECT.
VENT
(2 2)
3' c ag es
CAGES
(4 4)
3' c ag es
(2 5)
' l oc ke rs
(97) 2' lockers
(3 4)
2' lo ck er s
1186 LOCKERS
B95 SALEM ARMORY - EXISTING LOCKERS (ALTERNATE #3) create date: 16 February 2010 print date: 16 June 2022file: ...B95_20220616_existing.dwg
(156) 2' Lockers
(66) 3' Cages
Totals
AutoCAD SHX Text maintain 6' aisle
| Sheets and Views |
| Layout2 |
File details come from the government source that posted it. Updated .