The provided file is a detailed architectural floor plan for Building 284, depicting a first-floor layout spanning 26,072 square feet (552 ACG). The plan meticulously illustrates room assignments and spatial configurations for various functional areas, including administrative spaces like the Commander's office, Deputy Director's area, conference rooms, and specialized zones such as a Mainframe Room, Vault, Systems Section, Computer Ops, and multiple storage and mechanical rooms. The floor plan uses color coding and includes precise room measurements, with individual room sizes ranging from 27 to 1,360 square feet.

Key operational areas include COMSEC (Communications Security) and IA (Information Assurance) sections, generator and electrical rooms, break rooms, and multiple hallways connecting different organizational segments. The layout reveals a complex, security-focused environment with dedicated spaces for mission-critical operations, suggesting this is likely a military or government facility with significant technological infrastructure requirements. Room designations like "Mission Sim", "Equipment Storage", and specialized storage areas indicate a technical, mission-oriented organizational structure with emphasis on secure, compartmentalized spaces.

View the file

Other files

File Type Posted
BLDG 284 RFI Questions with Answers.docx DOCX document
Flooring phases.jpg JPG image
Flooring Tiles 1.xlsx XLSX spreadsheet
SOW B284 flooring.docx DOCX document
RFQ B284 Raised Flooring.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 284 - FIRST FLOOR PLAN

00 8' 16'2' 4'

WOMEN

MEN

STORAGE

MAINFRAME ROOM

VAULT

SYSTEMS SECTION

COMPUTER OPS

H A

L L W

A Y

SUPERINTENDENT

CORRIDOR

COMSEC AND IA

MECHANICAL ROOM

CORRIDOR

ACC OVERSIIGHT

FIT

GENERATOR ROOM

BREAK ROOM

MEN

S T

O R

A G

E

WOMEN

HALLWAY

VACANT

ELECTRICAL CLOSET

HALLWAY

COMSEC

STORAGE

VACANT

SIM QA

COMSEC

E N

T R

Y W

A Y

WOMAN

MEN

103G

103A

105A

101A

107C

105B

103B

103F

103E

103C

105E

105C

105D

103D

107D

117A

117D

B

117C

113C

A

113B

113D

111G

111H

111D

111_I

109A

111F

101B

115D

115E

J

115F

111C

111B

115A

115B

115C

111A

CM VAULT

DTM

DTM

EQUIPMENT STORAGE

107B

STAIRS

DEPUTY

DIRECTOR

CONFERENCE

ROOM

MISSION SIM

MAINTENANCE

SECRETARY / EXECUTIVE

ASSISTANT

DEPUTY

COMMANDER

EXECUTIVE

OFFICER

SUPERINTENDENT

CONFERENCE

ROOM

COMMANDER

GROUP CSA

PROJECTOR ROOM

FIRST SERGEANT

FUNCTIONAL

MANAGER

H A

L L W

A Y

MECH.

ROOM

104G

104F

104B

104A

104E104D104C

111E

107F

ELEVATOR

LOBBY

552 ACG (26,072 SF)

COMSEC

202 SF

183 SF

381 SF

135 SF

491 SF

149 SF

156 SF

312 SF

290 SF

977 SF

32 SF

306 SF

29 SF

1,360 SF

371 SF

62 SF

421SF

630 SF

204 SF

425 SF

166 SF

389 SF

335 SF

749 SF

1,271 SF

2,082 SF

631 SF

VACANT

VACANT

550 SF

130 SF

COMM

107A

299 SF

448 SF

63 SF

554 SF

1,056 SF

STORAGE

27 SF

30 SF