This document is a specifications sheet for mobile weather stations issued by the Bureau of Indian Affairs Southwestern Regional Office, Division of Natural Resources, Water Resources & Irrigation, dated June 18, 2026.

The specification requires a research-grade mobile weather station comparable to the Campbell ET107, featuring a mounting tripod up to 10 feet in height and equipped with precipitation/rain gauge, temperature gauge, humidity sensor, wind speed and direction gauge, and solar radiation sensor. The system must include a data logger capable of automatically calculating evapotranspiration using the Penman-Monteith method, along with all required mounting, calibration, and power kits. The data logger must meet Campbell CR1000M or similar specifications, including a processor with CPU drive of 50 MB serial flash or greater, 16 single-ended or 8 differential analog input channels, data storage capacity of 50 MB or greater, program execution period of 100 ms to 1 day, and timing accuracy of ±3 minutes per year or greater. The tipping bucket rain gauge must comply with Texas Electronics TE525-5m or similar standards, with closure time of 135 ms or faster and bounce settling time of 0.75 ms or lower. Additional sensor requirements include solar radiation sensor (Campbell CS305-ET or similar) with spectral range of 300-1100 nm and measurement range of 0 to 2000 W/m², humidity and temperature sensors (Campbell HMP60-ETS or similar) with temperature range of -40 to 60°C and humidity accuracy of ±3-5%, and wind speed and direction gauge (Campbell MW 034B-ET) with range of 0 to 75 m/s and directional accuracy of ±5° or better. All sensors must be compatible with the data logger and mounting tripod with complete mounting kits and power sources included.

View the file

Other files

File Type Posted
B08_Attachment_1_Specs_Updated_0002.pdf PDF
Sol_140A0726Q0010_Amd_0002.pdf PDF
Sol_140A0726Q0010_Amd_0001.pdf PDF
B11_Q_A_140A0726Q0010_0001.docx DOCX document
Sol_140A0726Q0010.pdf PDF
B08_Attachment_2_IA_-_IEE_Representation_Form.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bureau of Indian Affairs Southwestern Regional Office

Division of Natural Resources, Water Resources & Irrigation

Specifications

Mobile Weather Stations

For ET measurements

June 18, 2026

General Description:

Research grade mobile weather station: Campbell, ET107 or similar

• Mounting Tripod: Up to 10 feet, 3 meters height

• Precipitation/Rain gauge (in or mm)

• Temperature gauge (F° or C°)

• Humidity sensor, relative humidity (RH%)

• Wind Speed & direction gauge (mph or meters/s)

• Solar Radiation Sensor (W/m2).

• Data Logger, that can automatically Calculate Evapotranspiration using Penman-Monteith method.

• Include all required mounting, calibration and power kits for sensors

Data Logger: Cambell CR1000M or similar

• Processor: CPU Drive: 50 MB serial flash, 2 MB flash, 7 MB RAM or greater.

• Analog Inputs: 16 single-ended or 8 differentials individually configured input channels or more. Range: in (mV) +/- 5000 to +/- 2.5, Resolution: in (µV) 1333 to 0.67.

• CPU Drive: 50 MB serial flash or greater

• Data Storage: 50 MB serial flash or greater

• Operating System: 2 MB flash

• Settings, Calibration, TLS Certificates and Key, System Information: 3 MB serial flash or greater

• Background Tasks and Table Information, Buffers, System Memory, Program Variables: 7 MB RAM or greater

• Program Execution Period: 100 ms to 1 day

• Resolution: 1 ms or lower

• Accuracy: ±3 min. per year or greater

Tipping Bucket Rain Gauge: Texas Electronics, TE525-5m TE525 or similar

• Closure time: 135 ms or faster

• Bounce settling time: 0.75 ms or lower

• Resolution: 1 tip

Solar Radiation Sensor: Cambell, CS305-ET or similar

• Spectral range: 300-1100 nm minimum

• Measurement range: 0 to 2000 W/m2 or greater

Humidity and temperature sensors: Cambell, HMP60-ETS or similar

• Temperature Range: -40-60 °C or greater

• Humidity Range: 0% – 100%

• Temperature Accuracy: ±0.6 °C or greater

• Humidity Accuracy: ±5 % (–40 °C to 0 °C), ±3 % (0 °C to 40 °C), for less than 90% humidity

Wind Speed and Direction: Cambell, MW 034B-ET

• Wind Speed Range: 0 to 75 m/s (0–167 mph) or greater

• Wind Direction Range: 0° – 360°

• Wind Speed Accuracy: Accuracy: <10.14 m/s: ±0.1 m/s (±0.25 mph)

≥10.14 m/s: ±1.1% of true speed or greater

• Wind Direction Accuracy: ±5° or better