B08_Att_2d_Drawings_(2-19-25).pdf
PDF 18 MB Posted
- Attached to
- CHCU 310250 Federal contract opportunity
- Solicitation number
- 140P2025R0078
About this file
These are detailed architectural and landscape design drawings for the Replace Obsolete Housing project at Chaco Culture National Historic Park in New Mexico. The comprehensive set of drawings includes multiple sheets covering site disturbance, demolition, utility, grading, and landscape plans for multiple housing buildings (Buildings A and B). The documents are dated October 2024 and prepared by IMEG for the National Park Service.
Key technical details include foundation plans with specific grid dimensions, structural notes specifying concrete and wood construction requirements, and landscape design specifications for stone walls, wire mesh fencing, and native seed restoration. The drawings provide precise architectural and civil engineering details for replacing existing housing structures, with careful consideration for the sensitive historic park environment, including provisions for potential archaeological resource discoveries during construction. The project involves multiple building units with complex site integration, foundation designs, and landscape restoration elements.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C-46
CLIN 9
SITE DISTURBANCE PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
10/09/2024
C-47
OVERALL SITE PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
GAW
DATE:
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-48
DEMOLITION PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
GAW
DATE:
RESTORATION NOTES
1. EXCAVATED AREAS SHALL BE BACKFILLED TO REESTABLISH EXISTING OR PROPOSED GRADE.
2. DISTURBED AREAS SHALL BE SEEDED WITH THE APPROVED NATIVE SEED MIX TO REESTABLISH VEGETATION.
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-49
OVERALL UTILITY PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
MATC
H B
ASE B
ID
SEE S
HEET
C-7
UTILITY NOTES
1. ALL STORMWATER PIPING SHALL BE ADS N-12 HDPE, ADS HP-STORM PP, OR APPROVED EQUIVALENT.
2. ALL STORMWATER MANHOLES SHALL 72"Ø BOX BASE MANHOLES WITH 24"Ø RING & COVERS.
3. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
4. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
5. ANY WATER LINE CROSSING WITH LESS THAN 2' VERTICAL CLEARANCE SHALL HAVE A 6" LAYER OF EXTRUDED
POLYSTRENE FOAM (XPS) WRAPPED AROUND THE WATER MAIN TO A MINIMUM OF 5' ON EACH SIDE OF THE STORM PIPE.
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-50
OVERALL GRADING PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-51
DETAILED GRADING PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
GROUTED RIPRAP RUNDOWN CHANNEL CENTERLINE PROFILE
GROUTED RIPRAP RUNDOWN CHANNEL & SEDIMENTATION BASIN
PLAN
4X VERTICAL EXAGGERATION
SECTION A-A
4X VERTICAL EXAGGERATION
SECTION B-B
4X VERTICAL EXAGGERATION
ACCESS ROAD CENTERLINE PROFILE
4X VERTICAL EXAGGERATION
135 DEG.
C-52
CLIN 9
DETAILED GRADING PROFILE
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
RIPRAP RUNDOWN CHANNEL & SEDIMENTATION POND
GEOMETRIC PLAN
C-53
CLIN 9
GEOMETRIC PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
STORM PIPE
PLAN
170 DEG.
M
AT
CH
B
AS
E
BI
D
SE
E
SH
EE
T C-
C-54
CLIN 9
STORM PIPE
PLAN & PROFILE (IN6 to IN4)
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
NOTES
1. ALL STORMWATER PIPING SHALL BE ADS N-12 HDPE, ADS HP-STORM PP, OR APPROVED EQUIVALENT.
2. ALL STORMWATER MANHOLES SHALL 72"Ø BOX BASE MANHOLES WITH 24"Ø RING & COVERS.
3. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
4. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
5. ANY WATER LINE CROSSING WITH LESS THAN 2' VERTICAL CLEARANCE SHALL HAVE A 6" LAYER OF EXTRUDED
POLYSTRENE FOAM (XPS) WRAPPED AROUND THE WATER MAIN TO A MINIMUM OF 5' ON EACH SIDE OF THE STORM PIPE.
M
AT
C H
C
LI
N
SE
E
SH
EE
T C
-3
MATCH CLIN 8
SEE SHEET C-44
FOR PIPE PROFILES, REFER TO CLIN 7 & CLIN 8 SHEETS
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-55
CLIN9
DETAILS
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
GAW
DATE:
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
GROUTED RIPRAP RUNDOWN CHANNEL
ISOMETRIC VIEW
(ONLY ONE COMPLETE SIDE SHOWN FOR CLARITY)
SCALE: NTS
SEDIMENTATION BASIN
ISOMETRIC VIEW
SCALE: NTS
OUTLET STRUCTURE
SCALE: NTS
GROUTED RIPRAP RUNDOWN CHANNEL - TYPICAL SECTION
SCALE: NTS
CONCRETE TRICKLE CHANNEL DOWEL
SCALE: NTS
LADDER STEP
SCALE: NTS
LADDER SURFACE
SCALE: NTS
LADDER SPACING
SCALE: NTS
WEIR/SPILLWAY CONNECTION
SCALE: NTS
MAINTENANCE ACCESS ROAD
SCALE: NTS
C-56
CLIN 9
DETAILS
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
GAW
DATE:
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
W C
W C
BEDROOM 3
BEDROOM 2
BEDROOM 1
HALL
BATH 2
BATH 1
LAUNDRY
W.H.
KITCHEN
LIVING ROOM
WC
WC
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
CLO
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
FF = 6197.63
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
SALVAGE STONE FROM MASONRY WALLS
SALVAGE STONE FROM MASONRY WALLS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
L2.00
GRAVEL SCREENING
PATH
SEE CIVIL TO COORDINATE SEED MIX
PHASING. CLIN 7, 8, AND 9
SEE CIVIL TO COORDINATE SEED MIX
PHASING. CLIN 7, 8, AND 9
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
SALVAGE STONE FROM MASONRY WALLS
SALVAGE STONE FROM MASONRY WALLS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
BASE LANDSCAPE PLAN
L1.00
NORTH
0' 180'60'30'
1" = 60'
SHEET
L1.01
SHEET
L1.02
SHEET
L1.03
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
STONE WALL
PRIVACY FENCE
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
CIVIL DRAWINGS
064 of 155EXP 12/31/2024
W C
BEDROOM 3
BEDROOM 2
BEDROOM 1
HALL
BATH 2
BATH 1
LAUNDRY
W.H.
KITCHEN
LIVING ROOM
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
CLO
FF = 6199.18
FF = 6197.63
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
5'
4'-4"
5'-9"
10'
29'-5 2"
'-1
11 2" 1'
-6
17'-2"
L2.00
1' STONE WALL
L2.00
2' STONE WALL
CONCRETE PAVING,
SEE CIVIL DRAWINGS
CONCRETE PAVING, SEE
CIVIL DRAWINGS
WALL HEIGHT TRANSITION, TYPICAL
32'-9 12 "
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
BASE LANDSCAPE
ENLARGEMENTL1.01
NORTH
30'10'5'0'
1" = 10'
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
STONE WALL
PRIVACY FENCE
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
065 of 155EXP 12/31/2024
WC
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
CLO
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
12'-3 2"
15'-3" 5'-1"
28'-3"
4'
5'5'
5'
4'-4"
L2.00
2' STONE WALL
L2.00
1' STONE WALL
L2.00
1' STONE WALL
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
CONCRETE PAVING, SEE CIVIL DRAWINGS
4'-5"
53'-3 12 "
5'-7"
5'-7" 14'-61
2" 5'-7" 8'-101
2" 5'-7" 18'-101
2"
5'-9"
2'-2"5'-7"
3'
3'
3'
3'
3'
3'
2'-7"
7'-4" 5'-9"
10'
5'-4 2"
18'
17'-9 2"
4'-2"
14'-8 2" 8'-11
12 "
5'-1 12 "
12'-10 12"
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
WALL HEIGHT TRANSITION,
TYPICAL
L2.02
PRIVACY FENCING
13' 5'-6" 10'
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
L1.02
NORTH
30'10'5'0'
1" = 10'
BASE LANDSCAPE
ENLARGEMENT
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
STONE WALL
PRIVACY FENCE
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
066 of 155EXP 12/31/2024
WC
WC
BEDROOM 2
BATH 1
BATH 2
BEDROOM 1
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
L2.00
4'-8"
9'-6"
8'-8"
21'
5'
28'-3"
5'
15'-9"
4'
5'
L2.00
1' STONE WALL
L2.00
2' STONE WALL
CONCRETE PAVING, SEE
CIVIL DRAWINGS
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
GRAVEL SCREENING
PATH
L2.00
1' STONE WALL
23'-1"
14'-4 2"
49'-11"
44'-3"
10' 12' 5'-9" 2'-11
12 "
5'-7"
24'-7"
5'-7" 14'-11"
5'-7"
20'-2"
3'
3'
3'
5'-9" 6'-11
12 "
5'-9" 6'-11
12 " 3'
5'-7"
5'-7"
11'
5'-7"
5'-8"
5'-9"
8'
CONCRETE PAVING, SEE
CIVIL DRAWINGS
19'-11 12 "9'-5
12 "
4'-7"5'-7"
27'
22'-11"
L2.02
PRIVACY FENCING
L2.02
PRIVACY FENCING
10' 5'-9"
13'-3 12 "
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
L1.03
NORTH
30'10'5'0'
1" = 10'
BASE LANDSCAPE
ENLARGEMENT
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
STONE WALL
PRIVACY FENCE
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
067 of 155EXP 12/31/2024
W C
BEDROOM 3
BEDROOM 2
BEDROOM 1
HALL
BATH 2
BATH 1
LAUNDRY
W.H.
KITCHEN
LIVING ROOM
WC
WC
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
CLO
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
FF = 6197.63
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
SALVAGE STONE FROM MASONRY WALLS
SALVAGE STONE FROM MASONRY WALLS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
L2.00
GRAVEL SCREENING
PATH
SEE CIVIL TO COORDINATE SEED MIX
PHASING. CLIN 7, 8, AND 9
SEE CIVIL TO COORDINATE SEED MIX
PHASING. CLIN 7, 8, AND 9
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
SALVAGE STONE FROM MASONRY WALLS
SALVAGE STONE FROM MASONRY WALLS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
RESTORE ALL DISTURBED AREAS WITH
SEED MIX, TYPICAL, SEE SPECIFICATIONS
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
LANDSCAPE PLAN
- CLIN 6L1.10
NORTH
0' 180'60'30'
1" = 60'
SHEET
L1.11
SHEET
L1.12
SHEET
L1.13
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
14.CLIN 5 INCLUDES
14.1. CONCRETE PAVING TO REAR OF BUILDINGS
15.CLIN 6 INCLUDES
15.1. ORNAMENTAL FENCING AND GATES
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
PRIVACY FENCE
FENCE - CLIN 6
STONE WALL
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
068 of 155EXP 12/31/2024
W C
BEDROOM 3
BEDROOM 2
BEDROOM 1
HALL
BATH 2
BATH 1
LAUNDRY
W.H.
KITCHEN
LIVING ROOM
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
CLO
FF = 6199.18
FF = 6197.63
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
15'
4'
34'-9"
47'-3"
4' 11'
L2.01
WIRE MESH FENCING -
CLIN 6
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
LANDSCAPE ENLARGEMENT
- CLIN 6L1.11
NORTH
30'10'5'0'
1" = 10'
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
14.CLIN 5 INCLUDES
14.1. CONCRETE PAVING TO REAR OF BUILDINGS
15.CLIN 6 INCLUDES
15.1. ORNAMENTAL FENCING AND GATES
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
PRIVACY FENCE
FENCE - CLIN 6
STONE WALL
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
069 of 155EXP 12/31/2024
WC
WC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
CLO
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
12'
L2.01
WIRE MESH FENCING -
CLIN 6
15'
27'-6"
4' 1'
12'
10'-21 2"
4' 13'-6"
L2.01
WIRE MESH FENCING -
CLIN 6
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
L1.12
NORTH
30'10'5'0'
1" = 10'
LANDSCAPE ENLARGEMENT
- CLIN 6
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
14.CLIN 5 INCLUDES
14.1. CONCRETE PAVING TO REAR OF BUILDINGS
15.CLIN 6 INCLUDES
15.1. ORNAMENTAL FENCING AND GATES
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
PRIVACY FENCE
FENCE - CLIN 6
STONE WALL
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
070 of 155EXP 12/31/2024
WC
WC
BEDROOM 2
BATH 1
BATH 2
BEDROOM 1
STORAGE
BEDROOM 2
LIVING ROOM
HALL
BATH 2
BATH 1
BEDROOM 1
MECH/W.H.
KITCHEN
LAUNDRY
WC
WC
WC
WC
WC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
STORAGE
LIVING ROOM
BEDROOM 2
KITCHEN
HALL
LAUDRY
MECH/W.H. BEDROOM 1
BATH 1
BATH 2
BEDROOM 2
LIVING ROOM
BATH 2
BATH 1
BEDROOM 1
KITCHEN
MECH/W.H.
LAUDRY
HALL
CLO
CLO
FF = 6199.18
FF = 6200.85
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
L2.01
WIRE MESH FENCING -
CLIN 6
L2.01
WIRE MESH FENCING -
CLIN 6
8'
14'-101 2"
4' 7'-3"
9'-3"
4'
15'-2 2"
12'
7'-3" 4'
3'-0 2"
11'
L2.01
WIRE MESH FENCING -
CLIN 6
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
L1.13
NORTH
30'10'5'0'
1" = 10'
LANDSCAPE ENLARGEMENT
- CLIN 6
1. CONTRACTOR RESPONSIBLE FOR FIELD LAYOUT OF
ALL NEW IMPROVEMENTS. DIGITAL FILES OF
GEOMETRIC INFORMATION WILL BE PROVIDED UPON
REQUEST IN AUTOCAD FORMAT. NO ADDITIONAL
PAYMENT WILL BE MADE FOR ADJUSTMENTS
NECESSARY TO CONSTRUCT THE WORK AS DRAWN.
2. CONTRACTOR RESPONSIBLE TO COORDINATE WORK
IN ORDER TO OBTAIN APPROVAL OF ALL LAYOUT BY
OWNERS REPRESENTATIVE PRIOR TO
CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE
MADE TO CORRECT WORK IF CONSTRUCTED
INCORRECTLY WITHOUT PRE-APPROVAL BY OWNERS
REPRESENTATIVE.
3. CONTRACTOR RESPONSIBLE TO MAINTAIN ALL
LAYOUT STAKES DURING CONSTRUCTION. NO
ADDITIONAL PAYMENT WILL BE MADE TO REPLACE
LAYOUT STAKES.
4. ALL WALLS ARE DIMENSIONED TO FACE OF WALL
UNLESS OTHERWISE NOTED.
5. ALL DIMENSIONS FROM ROADWAY ARE FROM BACK OF
CURB UNLESS OTHERWISE NOTED.
6. ALL CURVES AND RADII TO BE SMOOTH AND NOT
SEGMENTED.
7. CONTRACTOR TO PROVIDE LAYOUT STAKES EVERY 10
FEET MINIMUM FOR LARGE ARCS WHERE RADIUS
POINTS ARE NOT ACCESSIBLE.
8. ADJUSTMENT TO STAKE LOCATIONS DUE TO
DISCREPANCIES BETWEEN COORDINATES AND
DIMENSIONS IS INCIDENTAL TO THE CONTRACT. NO
ADDITIONAL PAYMENTS WILL BE MADE FOR THIS
WORK.
9. CONTRACTOR RESPONSIBLE TO TAKE DELIVERY,
ASSEMBLE AND INSTALL ALL MATERIALS AND
FURNISHINGS PER MANUFACTURER'S INSTRUCTIONS.
10.PLACE CONTROL AND EXPANSION JOINTS AS SHOWN
ON PLANS AND DETAILS FOR ALL CURBS, WALKS,
WALLS, STEPS, AND CONCRETE PAVING. WHERE
JOINTS ARE NOT SHOWN, PLACE CONTROL JOINTS A
MAXIMUM OF 10 FEET ON CENTER, EXPANSION JOINTS
A MAXIMUM OF 30 FEET ON CENTER, AND BETWEEN
ALL SEPARATE POURS.
11.SEED LIMIT LINE IS APPROXIMATE. SEED TO LIMITS OF
GRADING AND DISTURBANCE. CONTRACTOR
RESPONSIBLE FOR RESTORATION OF ANY
UNAUTHORIZED DISRUPTION OUTSIDE OF
DESIGNATED CONSTRUCTION AREA.
12.CONTRACTOR RESPONSIBLE FOR EROSION CONTROL
IN ALL SEEDED AREAS.
13.REFER TO SPECIFICATIONS FOR ADDITIONAL
CONDITIONS, STANDARDS AND NOTES.
14.CLIN 5 INCLUDES
14.1. CONCRETE PAVING TO REAR OF BUILDINGS
15.CLIN 6 INCLUDES
15.1. ORNAMENTAL FENCING AND GATES
LEGEND
CONCRETE PAVING, SEE
CIVIL DRAWINGS
NOTES
CLIN 5 CONCRETE PAVING,
SEE CIVIL DRAWINGS
PRIVACY FENCE
FENCE - CLIN 6
STONE WALL
NATIVE SEED MIX
EJ EXPANSION JOINT, SEE
071 of 155EXP 12/31/2024
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
COMPACTED SUBGRADE
FINISH GRADE
LOCAL RECLAIMED STONE.
MATCH EXISTING WALLS. SEE
PHOTOS
MORTAR STONE TOGETHER,
FILL ALL VOIDS WITH MORTAR
2' -0
1'-6"
SLOPE TOP SURFACE TO
OUTER EDGE. USE LARGE
STONES FOR TOP OF WALL
MORTAR JOINT, FLUSH WITH
FACE OF STONE. SEE
SPECIFICATIONS
COMPACTED AGGREGATE
BASE COURSE
MASONRY WEEP, 24" O.C.
6" 1'-6"
6"
2'-6"
3" 1'
-0
2' STONE WALL
3/4" = 1'-0"
COMPACTED SUBGRADE
FINISH GRADE
LOCAL RECLAIMED STONE.
MATCH EXISTING WALLS. SEE
PHOTOS
MORTAR STONE TOGETHER,
FILL ALL VOIDS WITH MORTAR
1' -0
1'-6"
SLOPE TOP SURFACE TO
OUTER EDGE. USE LARGE
STONES FOR TOP OF WALL
MORTAR JOINT, FLUSH WITH
FACE OF STONE. SEE
SPECIFICATIONS
COMPACTED AGGREGATE
BASE COURSE
MASONRY WEEP, 24" O.C.
1' STONE WALL
3/4" = 1'-0"
3"
1' -3
6" 1'-6" 6"
LANDSCAPE DETAILS
L2.00
TRANSITION BETWEEN WALL
HEIGHTS, TYPICAL
END OF WALL, TYPICAL
LAYING PATTERN, TYPICAL TOP OF WALL, TYPICAL
STONE WALL REFERENCE IMAGES
1" = 1'-0"
STONE RECLAMATION NOTES
1. STONE TO BE RECLAIMED FROM EXISTING STONE
WALLS TO BE DEMOLISHED. REFER TO REMOVALS
PLANS FOR LOCATIONS.
2. STONE TO BE CLEANED AND FREE OF ALL MORTAR /
GROUT PRIOR TO USE.
3" 6"
GRAVEL SCREENING PATH
1" = 1'-0"
1" ADJACENT MATERIAL
VARIES, SEE PLANS
(2) 24" STAKES, 32" O.C.
COMPACTED AGGREGATE
BASE COURSE
COMPACTED SUBGRADE
GRAVEL SCREENINGS.
MATCH EXISTING
GRAVEL
METAL EDGING
072 of 155EXP 12/31/2024
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
LANDSCAPE DETAILS
L2.01
WIRE MESH FENCING - CLIN 6
1" = 1'-0"
4' 1'
-6
6" 1'
11 2" E
Q
E Q
E
Q
11 2"
11 4" M in
" M ax
4' 4'
FENCE ELEVATION FENCE SECTION GATE ELEVATION
3" 6"
3"
3" 3"
4'
3"
3" X 3" 16 GA. POWDER COATED STEEL
POST, POST TO EXTEND TO BOTTOM
OF GRAVEL BASE, TYP.
3" X 3" X 14" POWDER COATED FRAME,
MITER AND WELD CORNERS, DRILL 38"
HOLES PRIOR TO POWDER COATING,
TYP.
3" - 6 GA. POWDER COATED WELDED
WIRE MESH, WELD TO 3" FRAME PRIOR
TO POWDER COATING, TYP.
12" DIA. X 18" CONCRETE FOOTING, TYP.
FREE DRAİNİNG GRAVEL BASE MATERİAL, TYP.
COMPACTED SUBGRADE, TYP.
4" X 4" 16 GA. POWDER COATED GATE POST, POST
TO EXTEND TO BOTTOM OF GRAVEL BASE, TYP.
4"
1"
2" X 4" SQUARE TUBE 16 GA. POWDER COATED
STEEL FRAME MITER AND WELD CORNERS, TYP.
3" X 3" X 14" POWDER COATED FRAME, MITER AND
WELD CORNERS, DRİLL 38" HOLES PRIOR TO
POWDER COATING, TYP.
8" DIA. HOLES FOR 5
16" DİA. STAINLESS
STEEL SHEET METAL SCREWS, DRILL
HOLES PRIOR TO POWDER COATING, TYP.
CONCRETE
FOOTING, TYP.
AGGREGATE
BASE, TYP.
NOTES:
1. CONSTRUCT ALL PANEL ASSEMBLIES AND OTHER WELDED ITEMS PRIOR TO POWDER
COATING.
2. IF ANY TOUCH-UP IS NEEDED ON SITE, THE SURFACE SHALL BE GROUND DOWN TO BARE
METAL, CLEANED, A RUST INHIBITOR APPLIED, AND TWO COATS OF MARINE GRADE SPRAY
PAINT APPLIED TO MATCH POWDER COAT COLOR.
3. POWDERCOAT COLOR TO BE BLACK
ARCHITECTURAL
IRON DESIGNS
MAMMOTH 180 HINGE
WITH CLOSER OR
APPROVED EQUAL,
TYP 2 PER GATE
ARCHITECTURAL IRON DESIGNS LOCINOX
MORTISE GATE LOCK OR APPROVED EQUAL, TYP
073 of 155EXP 12/31/2024
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
JEB
BCS
ZC/SA/JEB
189893
ISS
UE
F
OR
F
INA
L
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING10/10/2024
LANDSCAPE DETAILS
L2.02
PRIVACY FENCING
1" = 1'-0"
4' 1'
-6
6"
1'
11 2" E
Q
E Q
E
Q
11 2"
11 4" M in
" M ax
4'
FENCE ELEVATION FENCE SECTION
3"
3" 3"
3" X 3" 16 GA. POWDER COATED STEEL
POST, POST TO EXTEND TO BOTTOM
OF GRAVEL BASE, TYP.
3" X 3" X 14" POWDER COATED FRAME,
MITER AND WELD CORNERS, DRILL 38"
HOLES PRIOR TO POWDER COATING,
TYP.
FLAT WIRE WEAVE PANEL, 25% OPEN
AREA. WELD TO 3" FRAME PRIOR TO
POWDER COATING, TYP.
12" DIA. X 18" CONCRETE FOOTING, TYP.
FREE DRAINING GRAVEL BASE MATERIAL, TYP.
COMPACTED SUBGRADE, TYP.
8" DIA. HOLES FOR 5
16" DIA. STAINLESS STEEL
SHEET METAL SCREWS, DRILL HOLES PRIOR
TO POWDER COATING, TYP.
CONCRETE
FOOTING, TYP.
AGGREGATE
BASE, TYP.
NOTES:
1. CONSTRUCT ALL PANEL ASSEMBLIES AND OTHER WELDED ITEMS PRIOR TO POWDER
COATING.
2. IF ANY TOUCH-UP IS NEEDED ON SITE, THE SURFACE SHALL BE GROUND DOWN TO BARE
METAL, CLEANED, A RUST INHIBITOR APPLIED, AND TWO COATS OF MARINE GRADE SPRAY
PAINT APPLIED TO MATCH POWDER COAT COLOR.
3. POWDERCOAT COLOR TO BE BLACK
074 of 155EXP 12/31/2024
STRUCTURAL GENERAL NOTES
DIVISION 1 - GENERAL REQUIREMENTS
1.1 CONSTRUCTION MEANS AND METHODS
A. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE COURSE OF THE WORK, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.
B. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INCLUDE THE METHOD OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE
ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION.
SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO: BRACING, SHORING
FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES,
AND PARTIALLY COMPLETED WORK. TEMPORARY SUPPORTS REQUIRED FOR
STABILITY OF THE STRUCTURE DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION
SHALL BE DESIGNED AND PROVIDED BY CONTRACTOR.
1.2 SUBMITTALS
A. SUBMITTALS PREPARED BY SUBCONTRACTORS SHALL BE REVIEWED BY CONTRACTOR
PRIOR TO SUBMITTING TO GOVERNMENT.
B. PRODUCT DATA: FOR EACH TYPE OF MANUFACTURED MATERIAL AND PRODUCT
INDICATED IN CONSTRUCTION DOCUMENTS.
C. MATERIAL TEST REPORTS: FROM A QUALIFIED TESTING AGENCY INDICATING
AND INTERPRETING TEST RESULTS FOR COMPLIANCE WITH REQUIREMENTS
INDICATED, BASED ON COMPREHENSIVE TESTING OF CURRENT MATERIALS.
D. SHOP DRAWINGS: FOR EACH STRUCTURAL COMPONENT AS INDICATED ON CONSTRUCTION
DOCUMENTS.
E. WARRANTIES: SUBMIT MANUFACTURER'S AND INSTALLER'S SAMPLE WARRANTIES
FOR EACH TYPE OF MANUFACTURED MATERIAL AND PRODUCT INDICATED IN
CONSTRUCTION DOCUMENTS.
F. ALL SUBMITTALS REVIEWED BY GOVERNMENT ARE REVIEWED FOR GENERAL
CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL
COMPLIANCE WITH THE INFORMATION INCLUDED IN THE CONTRACT DOCUMENTS.
ANY ACTION INDICATED IS SUBJECT TO THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR CORRELATING AND CONFIRMING
DIMENSIONS AT THE JOB SITE, CHOICE OF FABRICATION PROCESSES AND
TECHNIQUES OF CONSTRUCTION, AND COORDINATION OF THE WORK WITH THAT
OF OTHER TRADES.
1.3 QUALITY REQUIREMENTS
A. REFERENCE TO STANDARD SPECIFICATIONS OR CODES OF ANY TECHNICAL
SOCIETY, ORGANIZATION, OR ASSOCIATION OR TO CODES OF LOCAL OR
STATE AUTHORITIES, SHALL MEAN THE STANDARDS IN EFFECT AS OF DATE
OF THE CONTRACT DOCUMENTS, UNLESS OTHERWISE NOTED.
B. DRAWINGS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH SPECIFICATIONS
OR CODES OF ANY TECHNICAL SOCIETY, ORGANIZATION, OR ASSOCIATION.
C. ALL OMISSIONS AND CONFLICTS WITHIN THE CONTRACT DOCUMENTS SHALL
BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE
PRIOR TO PROCEEDING WITH THE WORK.
F. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE JOB SITE.
ANY DISCREPANCIES BETWEEN THE CONDITIONS FOUND AND THOSE INDICATED
IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF
THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO PROCEEDING WITH
THE WORK.
E. NO PIPES, DUCTS, CHASES, ETC. SHALL BE PLACED IN STRUCTURAL BEAM,
FOUNDATIONS AND COLUMN MEMBERS NOR SHALL ANY STRUCTURAL MEMBER
BE CUT FOR PIPES, DUCTS, ETC., UNLESS NOTED OTHERWISE. NOTIFY THE
CONTRACTING OFFICER'S REPRESENTATIVE WHEN DOCUMENTS BY OTHER DISCIPLINES
SHOW OPENINGS, POCKETS, ETC. NOT INDICATED IN THE STRUCTURAL DRAWINGS
BUT ARE LOCATED IN STRUCTURAL MEMBERS. CONTRACTOR SHALL OBTAIN
PRIOR WRITTEN APPROVAL FROM THE CONTRACTING OFFICER'S REPRESENTATIVE
FOR INSTALLATION OF SUCH PIPES, DUCTS, CHASES, ETC.
F. DETAILS LABELED "TYPICAL" ON THE STRUCTURAL DRAWINGS APPLY TO ALL
SITUATIONS OCCURRING ON PROJECT THAT ARE THE SAME OR SIMILAR TO
THOSE LOCATIONS SPECIFICALLY INDICATED. WHERE A DETAIL IS NOT INDICATED,
THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR CONDITIONS.
G. CONTRACTOR DESIGNED ELEMENTS SHALL BE DESIGNED BY LICENSED PROFESSIONAL
ENGINEERS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, DESIGN LOAD
DATA, SUPPORT REACTIONS, AND CERTIFICATION THAT ELEMENTS WERE DESIGNED
FOR LOADS SPECIFIED IN THE CONTRACT DOCUMENTS OR IN THE BUILDING
CODE. ALL DOCUMENTS NOTED SHALL BE SEALED BY THE LICENSED ENGINEER.
IF CRITERIA INDICATED ARE NOT SUFFICIENT, SUBMIT A WRITTEN REQUEST
FOR ADDITIONAL INFORMATION TO THE CONTRACTING OFFICER'S REPRESENTATIVE.
THE FOLLOWING ELEMENTS AND THEIR CONNECTIONS SHALL BE CONTRACTOR
DESIGNED:
1. STRUCTURAL INSULATED PANELS (SIPS) (OPTION 5)
1.4 STATEMENT OF SPECIAL INSPECTIONS
A. STRUCTURAL INSPECTIONS SHALL BE IN ACCORDANCE WITH CHAPTER 17 OF
THE 2021 INTERNATIONAL BUILDING CODE (IBC 2021).
1. THE CONTRACTOR SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO
PROVIDE INSPECTION DURING CONSTRUCTION ON THE TYPES OF WORK
LISTED UNDER SECTION 1705.
a. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL
DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE GOVERNMENT,
FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR
OPERATION REQUIRING SPECIAL INSPECTION.
b. THESE INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS SPECIFIED
IN SECTION 110 OF THE 2021 IBC.
B. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS:
1. CONCRETE CONSTRUCTION: REFER TO SECTION 1705.3 AND THE TABLE
ON S100.
2. SOILS: REFER TO SECTION 1705.6 AND THE TABLE ON S100.
1.5 STRUCTURAL SPECIAL INSPECTIONS
A. REFER TO ITEM 1.4.B.1 AND 1.4.B.2 ABOVE.
B. SPECIAL INSPECTION REPORTS SHALL BE FURNISHED TO THE GOVERNMENT.
DISCREPANCIES SHALL BE REPORTED TO THE CONTRACTING OFFICER'S REPRESENTATIVE.
C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT STATING THAT THE
STRUCTURAL WORK WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE,
PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
D. CONTRACTOR RESPONSIBILITY
1. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND
OR SESIMIC FORCE RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM
OR WIND OR SEISMIC RESISTING COMPONENT LISTED IN THE STATEMENT
OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF
RESPONSIBILITY TO THE GOVERNMENT PRIOR TO THE COMMENCEMENT OF
WORK ON THE SYSTEM OR COMPONENT.
2. THE CONTRACTOR’S STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE
FOLLOWING
a. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS
CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS.
b. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN
CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY
THE GOVERNMENT.
c. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR’S
ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND
THE DISTRIBUTION OF THE REPORTS
d. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) PERFORMING
SPECIAL INSPECTIONS.
1.6 DESIGN CRITERIA:
A. THE STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE THE INTERNATIONAL
BUILDING CODE, IBC, 2021 EDITION.
1. OCCUPANCY CATEGORY II
B. GRAVITY LOADS:
1. UNIFORM ROOF LIVE LOADS:
a. TYPICAL ROOF: 20 PSF
2. UNIFORM FLOOR LIVE LOADS (UNREDUCED):
a. RESIDENTIAL 40 PSF
3. SNOW:
a. GROUND SNOW 10.8 PSF
C. LATERAL LOADS:
1. WIND LOADS
a. BASIC WIND SPEED: 103 MPH
b. EXPOSURE: C
c. ENCLOSURE CLASSIFICATION: PARTIALLY ENCLOSED
d. INTERNAL PRESSURE COEFFICIENT: +/-0.55
2. EARTHQUAKE LOADS:
a. MAPPED SPECTRAL ACCELERATION AT SHORT PERIODS, SS: 0.168G
b. MAPPED SPECTRAL ACCELERATION AT 1-SECOND, S1: 0.059G
c. IMPORTANCE FACTOR: 1.00
d. SITE CLASS: D
e. SHORT PERIOD SITE COEFFICIENT, FA: 1.6
f. 1-SECOND PERIOD SITE COEFFICIENT, FV: 2.4
g. DESIGN SPECTRAL ACCELERATION AT SHORT PERIODS, SDS: 0.179G
h. DESIGN SPECTRAL ACCELERATION AT 1-SECOND, SD1: 0.095G
i. SEISMIC DESIGN CATEGORY: B
j. STRUCTURE:
1) BASIC STRUCTURAL SYSTEM: WOOD BEARING WALLS
2) SEISMIC RESISTING SYSTEM: WOOD SHEAR WALLS
3) RESPONSE MODIFICATION FACTOR, R: 6.5
4) DEFLECTION AMPLIFICATION FACTOR, CD: 4.0
5) SYSTEM OVERSTRENGTH FACTOR, OMEGA: 3.0
6) EQUIVALENT LATERAL FORCE PROCEDURE BASE SHEAR, V = 0.0275 X W
7) ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
DIVISION 2 - FOUNDATIONS
2.1 GENERAL
A. FOUNDATION DESIGN IS BASED UPON RECOMMENDATIONS IN THE GEOTECHNICAL
REPORT PREPARED BY TERRACON. DATED 07 FEBRUARY 2024.
B. CONTRACTOR'S GEOTECHNICAL CONSULTANT SHALL CERTIFY THE BEARING MEDIUM.
C. EXCAVATIONS SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER.
D. THE EXISTING SUBGRADE SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY.
2.2 FOOTINGS
A. OVEREXCAVATE AND RECOMPACT SITE SOILS A MINIMUM OF 2 FEET BENEATH
FOOTINGS AND IN ACCORDANCE WITH GEOTECHNICAL REPORT.
B. INDIVIDUAL SPREAD FOOTINGS AND CONTINUOUS FOOTINGS SHALL BEAR ON
COMPACTED ENGINEERED FILL WITH AN ALLOWABLE BEARING PRESSURE OF
2,000 PSF.
DIVISION 3 – CONCRETE
3.1 GENERAL
A. CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318-19 “BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” AND ACI 301-20 “SPECIFICATIONS
FOR STRUCTURAL CONCRETE”.
3.2 REINFORCING
A. STEEL BARS FOR CONCRETE REINFORCEMENT SHALL CONFORM WITH THE FOLLOWING.
1. REINFORCING STEEL SHALL BE ASTM A 615, GRADE 60 DEFORMED BARS,
WITH A MINIMUM YIELD STRENGTH OF 60 KSI UNLESS NOTED OTHERWISE.
2. WELDED WIRE FABRIC SHALL BE ASTM A 884, CLASS A, AS-DRAWN, PLAIN
STEEL WIRE AND SHALL BE CONTACT LAP SPLICED TWO FULL WIRE SPACES.
3. REINFORCING, INCLUDING DOWELS, SHALL BE SECURELY TIED AND CAST
WITH THE LOWER MEMBER. PLACING REINFORCING AFTER CONCRETE HAS
BEEN PLACED IS NOT PERMITTED.
4. FIELD BENDING OF REINFORCING PARTIALLY EMBEDDED IN CONCRETE
IS NOT ALLOWED UNLESS SPECIFICALLY NOTED IN THE STRUCTURAL
DOCUMENTS OR APPROVED BY ENGINEER.
5. PROVIDE DOWELS FROM FOUNDATION THE SAME GRADE, SIZE, AND NUMBER
AS VERTICAL WALL REINFORCING, UNLESS NOTED OTHERWISE.
6. PROVIDE CORNER BARS TO MATCH HORIZONTAL REINFORCING AT CORNERS
AND INTERSECTIONS.
7. MECHANICAL COUPLERS SHALL BE UNI-AXIAL TYPE OR EQUIVALENT CAPABLE
OF DEVELOPING 125% OF THE SPECIFIED TENSILE STRENGTH OF THE
SPLICED BAR.
3.3 CAST-IN-PLACE CONCRETE
A. REINFORCED CONCRETE SHALL HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE
STRENGTHS:
1. CLASS A 4,000 PSI NORMAL WEIGHT CONCRETE
2. CLASS B 4,000 PSI NORMAL WEIGHT CONCRETE
B. PLACE CONCRETE AS FOLLOWS:
1. CLASS A:
a. SLAB-ON-GRADE
2. CLASS B:
a. FOOTINGS
b. COLUMNS, WALLS
c. GIRDERS, BEAMS, STRUCTURAL SLABS
C. PROVIDE CONCRETE COVER FOR REINFORCING AS FOLLOWS:
1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH..................3”
2. CONCRETE EXPOSED TO EARTH OR WEATHER............. 2”
3. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
a. SLABS AND WALLS.............................3/4”
b. BEAMS AND COLUMNS... ..................1-1/2”
D. CONSTRUCTION JOINTS IN WALLS SHALL BE KEYED AND PLACED AT LOCATIONS
APPROVED BY CONTRACTING OFFICER'S REPRESENTATIVE.
E. INTERFACE OF CONSTRUCTION JOINTS SHALL BE ROUGHENED TO A FULL AMPLITUDE
OF 1/4". SURFACE OF CONSTRUCTION JOINTS SHALL BE CLEAN AND FREE
OF LAITANCE. IMMEDIATELY BEFORE NEW CONCRETE IS PLACED, CONSTRUCTION
JOINTS SHALL BE WETTED AND STANDING WATER REMOVED.
F. SEE ARCHITECTURAL DRAWINGS FOR WATERSTOPS.
G. PROVIDE COMPRESSIBLE FILLER AND SEALANT IN SLAB-ON-GRADE AND WALL
AND COLUMN INTERFACES THAT ARE NOT DOWELED TOGETHER.
H. PROVIDE 3/4" CHAMFER AT THE CORNERS OF COLUMNS AND WALLS WITH ANGLES
OF 90 DEGREES OR LESS.
DIVISION 4 – MASONRY- NOT USED
DIVISION 5 – METALS - NOT USED
DIVISION 5 – WOOD
5.1 GENERAL
A. WOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH ANSI/AWC NDS 2018
“NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION,” AITC TIMBER
CONSTRUCTION MANUAL, 6TH EDITION, AND ANSI/AWC SDPWS 2021 “SPECIAL
PROVISIONS FOR WIND AND SEISMIC DESIGN.”
B. ALL WOOD SHALL BE STORED ON SITE TO PREVENT WARPING, CUPPING, BOWING,
CROOKING AND TWISTING. USE ONLY MATERIAL THAT IS STRAIGHT. ALL
WOOD SHALL BE HELD OFF THE GROUND WITH SACRIFICIAL DUNNAGE BLOCKS.
C. ALL LUMBER SHALL BE GRADE STAMPED BY THE APPROPRIATE GRADING AGENCY.
D. ALL WOOD BEAMS, JOISTS, AND COLUMNS SHALL BE SOUTHERN PINE #2 GRADE
LUMBER OR BETTER. ALL WOOD STUDS SHALL BE SOUTHERN PINE #2 GRADE
LUMBER OR BETTER
E. PROVIDE SOLID BLOCKING AT LEAST 2” THICK AND FULL DEPTH OF JOIST
AT ENDS AND AT EACH SUPPORT OF JOIST. PROVIDE APPROVED BRIDGING
AT A MAXIMUM OF 8’-0” BETWEEN SUPPORTS.
F. LAMINATED BUILT-UP BEAMS OF 2x MEMBERS 10” DEEP OR LESS SHALL BE NAILED TOGETHER WITH NOT LESS THAN 16d NAILS @12” O.C., STAGGERED.
USE 2-20d COMMON NAILS AT ALL SUPPORTS. 2x MEMBERS DEEPER THAN
10” SHALL BE BOLTED TOGETHER WITH ½” DIAMETER BOLTS @16” O.C., STAGGERED,
WITH 2 BOLTS AT ALL SUPPORTS.
G. ALL STRUCTURAL PLYWOOD, OR OSB, SHALL BE C-D EXPOSURE 1 GRADE OR
BETTER AND SHALL CONFORM TO STANDARDS OF PS 1-19 OF A.P.A., U.N.O.
H. ALL WOOD BEAMS AND HEADERS SHALL BEAR ON A MINIMUM OF 2 CRIPPLE
STUDS AT EACH END UNLESS NOTED OR SHOWN OTHERWISE.
I. NAILING OF MEMBERS SHALL CONFORM TO THE NAILING SCHEDULE IN THE
IBC TABLE 2304.10.2, U.N.O.
J. MANUFACTURED NAILS AND BOLTS SPECIFIED SHALL BE USED FOR SIMPSON
TYPE CONNECTORS.
K. SIMPSON TYPE CONNECTORS SHALL BE USED FOR ALL WOOD CONNECTIONS NOT
SPECIFICALLY DETAILED.
L. MANUFACTURED JOISTS SHALL BE ERECTED IN ACCORDANCE WITH MANUFACTURER’S
RECOMMENDATIONS
M. MANUFACTURED JOISTS SHALL BE DESIGNED TO SUPPORT THE MAXIMUM LOADS
INDICATED IN THE MANUFACTURER’S LOAD TABLES.
5.2 ENGINEERED WOOD PRODUCTS
A. MATERIALS SHALL CONFORM TO THE FOLLOWING, UNLESS NOTE OTHERWISE:
1. LAMINATED-VENEER LUMBER: (LVL).
A. EXTREME FIBER STRESS IN BENDING, EDGEWISE: 2,600 PSI
FOR 12-INCH NOMINAL DEPTH MEMBERS.
B. MODULUS OF ELASTICITY, EDGEWISE: 1,900,000 PSI.
C. MANUFACTURED WITH EXTERIOR TYPE ADHESIVES.
5.3 SHEAR WALLS
A. 19/32” SHEATHING
1. BLOCKED UNLESS NOTED OTHERWISE.
B. ATTACH SHEATHING TO THE STUDS, BLOCKING, TOP AND BOTTOM PLATES
USING 10D NAILS SPACED AT 6” C/C AT PANEL EDGES AND 12” C/C
TO INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE.
C. ANCHOR SHEAR WALLS TO FOUNDATION WITH SIMPSON LTTP2 WITH (12) 0.148 x 1 1/2" NAILS
AND 5/8" DIAMETER F1554 GR. 36 HEAVY HEX HEAD ANCHOR BOLTS W/ 6" MIN EMBEDMENT.
LOCATE ANCHORS AT ENDS OF FULL-HEIGHT SHEAR WALL SEGMENTS AS SHOWN ON PLAN,
LOCATE ADDITIONAL INTERMEDIATE ANCHORS AT 32" O.C. MAX.
END OF STRUCTURAL GENERAL NOTES
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
189893 of
JO/SS
CG
NG
IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
TIO
N
DO
C
UM
EN
TS
:0 :4
A M
C A B S
P R O
JE
C
TS
N P S
C h a c o
H o u si n g B u ild in g
A N P S
C h a c o
H o u si n g
S B U
IL
D
IN
G
A .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
GENERAL NOTES &
SPECIAL INSPECTIONSS100
10/10/2024ABS PROJECT NUMBER - 4927512 075 155
TY
P
1" M
AX
FLOOR JOIST (TYP)
HEADER & BM TO
MATCH JOIST (TYP)
REFERENCE ARCH FOR SIZE
& LOCATION OF CRAWL
SPACE ACCESS OPENINGS 3'-0" MAX
'-0
M
A X
INSTALL HANGERS &
BACKER BLOCKS AS REQ'D
BY MANUFACTURER (TYP)
2' - 0"
MAX
4' - 0" 2' - 0"
M
IN4"
M
AX
2'
0"
FO
R
J O
IS
T
AS
R
EQ
'D
ADD'L #4 VERT, HK
@ TOP, DWL INTO
FTG (TYP)
TYP
3"
ADD'L #4
HORIZ
3"
FTG REINF
NOT SHOWN
FDN
WALL
ACCESS
OPENING
HK INTERUPTED
BARS (TYP)
TYP
2"
WALL REINF
(TYP)
2' - 0" ≤ 1' - 4" 2' - 0"
FO
R
J O
IS
T
AS
R
EQ
'D
1'
4"
ADD'L #4 VERT, HK
@ TOP, DWL INTO
FTG (TYP)
FTG REINF
NOT SHOWN
DUCT
OPENING
HK INTERUPTED
BARS (TYP)
TYP
2"
ADD'L #4x2'-0" HK
EA END (TYP)
REQ'D FOR
OPENINGS ≥ 9"
ADD'L #4x3'-0"
HK EA END (TYP)
T/FTG T/FTG
FOUNDATION WALL REINFORCING @ CRAWL SPACE ACCESS OPENINGS FOUNDATION WALL REINFORCING @ MECHANICAL OPENINGS
NOTE:
REFERENCE MECHANICAL & ARCHITECTURAL FOR SIZE & LOCATION OF CRAWL SPACE ACCESS & DUCT OPENINGS
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
189893 of
JO/SS
CG
NG
IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
TIO
N
DO
C
UM
EN
TS
:1 :0
A M
C A B S
P R O
JE
C
TS
N P S
C h a c o
H o u si n g B u ild in g
A N P S
C h a c o
H o u si n g
S B U
IL
D
IN
G
A .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
TYPICAL DETAILS
S101
10/10/2024ABS PROJECT NUMBER - 4927512
NTSS101
1 TYPICAL CORNER REINFORCING FOR CONCRETE WALLS & FOUNDATIONS
NTSS101
3 TYPICAL FLOOR OPENING FOR CRAWL SPACE ACCESS
NTSS101
2 TYPICAL FOUNDATION WALL OPENING DETAILS
076 155
A
B C
35' - 11 3/4" 19' - 1 1/4"
/4
/4
4'
0"
55' - 1"
8" 35' - 3 3/4" 8" 17' - 9 1/4" 8"
8"
/4
8"
0"
8" 3'
4"
8"
S300
S300
S300
S300
S300
S300
S300
S300SIM
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
189893 of
JO/SS
CG
NG
IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
TIO
N
DO
C
UM
EN
TS
:1 :0
A M
C A B S
P R O
JE
C
TS
N P S
C h a c o
H o u si n g B u ild in g
A N P S
C h a c o
H o u si n g
S B U
IL
D
IN
G
A .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
FOUNDATION PLAN
BUILDING AS200A
10/10/2024ABS PROJECT NUMBER - 4927512
1/4" = 1'-0"S200A
1 FOUNDATION PLAN - BUILDING A
N
PLAN NOTES:
1. SEE DETAILS FOR TOP OF FOOTING ELEVATION
2. PROVIDE OPENINGS IN FOUNDATION WALL FOR CRAWL SPACE ACCESS & MECHANICAL, REFERENCE…
This is the start of the file's text. The full file is on GovTribe.