NEW MEXICO
COLORADO
SHIPROCK
N E
W M
E X
IC
O
A R
IZ
O
N A
SEVEN SANTA
ALBUQUERQUE
GRANTS
EL MORRO
N.M.
N.M.
EL MALPAIS
THOREAU
GALLUP
LAKES
FE
ALAMOS
LOS
N.H.P.
CULTURE
CHACO
BLOOMFIELD
N.M.
RUINS
AZTEC
FARMINGTON
CUBA
MAINTENANCE & HOUSING AREA
MAINTENANCE
HOUSE
DUPLEX
APT. A
APT. B
NO SCALE
SHOP
EDGE OF
CLIFF
BLDG. 7
BLDG. 6
BLDG. 8
SITE
TLR. 8
RUINS
BLDG. 9
OFFICE
BLDGS.
MAINTENANCE
WELL
HOUSE
A
B
C
PROJECT LOCATION
V.C. HQ.
AREA
& HOUSING
MAINTENANCE
GALLO
PROJECT LOCATION
GALLO
McKINLEY COUNTY
SAN JUAN COUNTY
TO
SEVEN LAKES & 19
FAJADA
KIN KLIZHIN
RIVER
CHACO
TO 44
W
ASH
W
ASH
CHACO WASH
TO 550
HQ.
V.C.
LEGEND
TRAIL
RANGER STATION
PARK HEADQUARTERS
VISITOR CENTER
CAMPGROUND
DRAINAGE
UNPAVED ROAD
PARK BOUNDARY
PAVED ROAD
STATE LINE
NEW MEXICO
NORTHWESTERN
SCALE OF MILES
20 200
UNESCO
CHACO CULTURE NATIONAL HISTORICAL PARK
WORLD HERITAGE SITE
8,000
4,000
SCALE OF KILOMETERS
0 1 2
SCALE OF FEET
0 4,000
BASIC DATA: 310/20,003B 11/85; 310/80,043-1 6/95; COVER SHEET REVISED
& REDRAWN 2/96. UPDATED 10/98. SGS.
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
SAN JUAN AND MCKILEY NEW MEXICONORTHWESTERN
CONSTRUCTION DOCUMENTATION
DEPARTMENT OF THE INTERIOR
UNITED STATES
HOUSING PROTOTYPE DESIGN CATALOG
CHACO HOUSING
CHACO CULTURE NATIONAL
HISTORICAL PARK
STATEREGION COUNTY
LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING
OR
OR
Development (Title I)
Prepared in Accordance with Design by Design Development (Title I)
Construction Drawing Not Preceded
Approved by Superintendent on
Variance from Design Development (Title I)
Project Manager
Drawing No.
Date
Date
QUALITY DESIGN CERTIFICATIONSheetMark REVISION Date Initial
310250
PMIS/PKG NO.
DRAWING NO.
SHEET
189893
IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
TI
ON
DO
C
UM
EN
TS
EXP 12/31/2024
:4 :4
P
MB
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n yo n .r vt
001 of 155INTERMOUNTAIN
NORTH
WALL TAG
WINDOW TAG
SECTION
TAG
GRID LINE
ELEVATION
TAG
DETAIL
TAG
DOOR TAG
SIGNAGE TAG
ROOM HEIGHT
EQUIPMENT TAG
ALIGN/FLUSH
SURFACES
DETAIL
TAG
ROOM
NAME
ROOM
NUMBER
SQUARE
FOOTAGE
DETAIL
NUMBER
SHEET
NUMBER
INTERIOR
ELEVATION
TAG
DIMENSION
STRING
NORTH ARROW
KEYNOTE
X X.X
A-123
XX
XX
XX
XX XX
XX
X-XX-a
XX
XX
X X.X
X X.X
X X.X
X X.X
X'-X"
B
1"
INSULATION, RIGID
INSULATION, BATT
WOOD, ROUGH
PLYWOOD
WOOD, FINISH
STONE
GRAVEL, POROUS FILL
CONCRETE
EARTH
GYP. WALL BOARD, CAST
STONE, PLASTER,
GROUT, CEMENT,
MORTAR
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024 IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
UM
EN
TS
:1 :1
P M
B
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n yo n .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
GENERAL INFORMATION
AND ABBREVIATIONSG100
10/10/2024
Sheet Number Sheet Name D
D
D R
A F
T
C D
D
IF
S
IG
N E
D A
N D
S E
A L
E
FIRE PROTECTION
FP000 FIRE PROTECTION COVERSHEET ● ● ● ●
FP100 GROUND FLOOR - A FIRE PROTECTION PLAN ● ● ● ●
FP101 GROUND FLOOR - B FIRE PROTECTION PLAN ● ● ● ●
FP102 GROUND FLOOR - C FIRE PROTECTION PLAN ● ● ● ●
FP203 FIRE PROTECTION DETAILS AND SCHEDULES ● ● ● ●
Grand total: 155
Sheet Number Sheet Name D
D
D R
A F
T
C D
S
IG
N E
D A
N D
S E
A L
A603 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING B & C ● ● ● ●
A604 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING B ● ● ● ●
A605 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING B ● ● ● ●
A606 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING C ● ● ● ●
A700 WALL SECTIONS / RADON RISER DIAGRAM ● ● ● ●
A701 CONSTRUCTION DETAILS ● ● ●
A900 DOOR SCHEDULE & DETAILS ● ● ● ●
A901 WINDOW SCHEDULE & DETAILS ● ● ● ●
A902 MILLWORK DETAILS ● ● ●
A903 MILLWORK DETAILS ● ● ●
A950 ROOM FINISH SCHEDULE ● ● ● ●
A951 FINISH PLAN ● ● ● ●
MECHANICAL
M000 HVAC COVERSHEET ● ● ● ●
M100 GROUND FLOOR - A HVAC PLAN ● ● ● ●
M101 GROUND FLOOR - B HVAC PLAN ● ● ● ●
M102 GROUND FLOOR - C HVAC PLAN ● ● ● ●
M200 MECHANICAL DETAILS ● ● ● ●
M201 MECHANICAL DETAILS ● ● ● ●
M202 MECHANICAL DETAILS ● ●
M300 MECHANICAL CONTROLS ● ● ● ●
M400 MECHANICAL SCHEDULES ● ● ● ●
M401 MECHANICAL SCHEDULES ● ● ● ●
ELECTRICAL
E000 ELECTRICAL COVERSHEET ● ● ● ●
E010 ELECTRICAL SITE PLAN ● ● ● ●
E100 GROUND FLOOR - A POWER & SYSTEM PLAN ● ● ● ●
E101 GROUND FLOOR - B POWER & SYSTEM PLAN ● ● ● ●
E102 GROUND FLOOR - C POWER & SYSTEM PLAN ● ● ● ●
E200 GROUND FLOOR - A LIGHTING PLAN ● ● ● ●
E201 GROUND FLOOR - B LIGHTING PLAN ● ● ● ●
E202 GROUND FLOOR - C LIGHTING PLAN ● ● ● ●
E300 ROOF - A ELECTRICAL PLAN ● ● ● ●
E301 ROOF - B ELECTRICAL PLAN ● ● ● ●
E302 ROOF - C ELECTRICAL PLAN ● ● ● ●
E400 ELECTRICAL DETAILS ● ● ● ●
E500 ELECTRICAL ONE-LINE DIAGRAM ● ● ● ●
E501 SYSTEM ONE-LINE DIAGRAM ● ●
E600 ELECTRICAL SCHEDULES ● ● ● ●
E601 ELECTRICAL SCHEDULES ● ● ● ●
E602 ELECTRICAL SCHEDULES ● ● ● ●
E603 ELECTRICAL SCHEDULES ● ● ● ●
E700 LIGHTING COMPLIANCE CERTIICATE - BLDG B ● ● ●
E701 LIGHTING COMPLIANCE CERTIICATE - BLDG C ● ● ●
PLUMBING
P000 PLUMBING COVERSHEET ● ● ● ●
P100 GROUND FLOOR - A PLUMBING PLAN ● ● ● ●
P101 GROUND FLOOR - B PLUMBING PLAN ● ● ● ●
P102 GROUND FLOOR - C PLUMBING PLAN ● ● ● ●
P200 PLUMBING DETAILS ● ● ● ●
P201 PLUMBING ISOMETRICS ● ● ● ●
P300 PLUMBING SCHEDULES ● ● ● ●
Sheet Number Sheet Name D
D
D R
A F
T
C D
S
IG
N E
D A
N D
S E
A L
C-46 CLIN 9 SITE DISTURBANCE PLAN ● ●
C-47 CLIN 9 OVERALL SITE PLAN ● ●
C-48 CLIN 9 DEMOLITION PLAN ● ● ●
C-49 CLIN 9 OVERALL UTILITY PLAN ● ●
C-50 CLIN 9 OVERALL GRADING PLAN ● ●
C-51 CLIN 9 DETAILED GRADING PLAN ● ●
C-52 CLIN 9 DETAILED GRADING PROFILE ● ●
C-53 CLIN 9 GEOMETRIC PLAN ● ●
C-54 CLIN 9 STORM PIPE PLAN & PROFILE (IN6 TO IN4) ● ●
C-55 CLIN 9 DETAILS ● ●
C-56 CLIN 9 DETAILS ● ●
LANDSCAPE
L1.00 BASE LANDSCAPE PLAN ● ● ● ●
L1.01 BASE LANDSCAPE ENLARGMENT ● ● ● ●
L1.02 BASE LANDSCAPE ENLARGMENT ● ● ● ●
L1.03 BASE LANDSCAPE ENLARGMENT ● ● ● ●
L1.10 LANDSCAPE PLAN - CLIN 6 ● ● ●
L1.11 LANDSCAPE ENLARGEMENT - CLIN 6 ● ● ●
L1.12 LANDSCAPE ENLARGEMENT - CLIN 6 ● ● ●
L1.13 LANDSCAPE ENLARGEMENT - CLIN 6 ● ● ●
L2.00 LANDSCAPE DETAILS ● ● ● ●
L2.01 LANDSCAPE DETAILS ● ● ●
L2.02 LANDSCAPE DETAILS ● ●
STRUCTURAL
S100 GENERAL NOTES & SPECIAL INSPECTIONS ● ● ● ●
S101 TYPICAL DETAILS ● ● ● ●
S200A FOUNDATION PLAN BUILDING A ● ● ● ●
S200B FOUNDATION PLAN BUILDING B ● ● ● ●
S200C FOUNDATION PLAN BUILDING C ● ● ● ●
S201A FLOOR FRAMING PLAN BUILDING A ● ● ●
S201B FLOOR FRAMING PLAN BUILDING B ● ● ●
S201C FLOOR FRAMING PLAN BUILDING C ● ● ●
S202A ROOF FRAMING PLAN BUILDING A ● ● ●
S202B ROOF FRAMING PLAN BUILDING B ● ● ●
S202C ROOF FRAMING PLAN BUILDING C ● ● ●
S300 FOUNDATION SECTIONS ● ● ● ●
S400 ROOF FRAMING SECTIONS ● ● ●
ARCHITECTURAL
D010 ENLARGED SITE PLAN - DEMO ● ● ● ●
A010 ARCHITECTURAL SITE PLAN ● ● ● ●
A100 GROUND FLOOR - A - SINGLE FAMILY ● ● ● ●
A101 GROUND FLOOR - B - TWO HOMES ● ● ● ●
A102 GROUND FLOOR - C - THREE HOMES ● ● ● ●
A200 REFLECTED CEILING PLANS ● ● ● ●
A300 ROOF PLAN ● ● ● ●
A400 EXTERIOR ELEVATIONS - BUILDING A ● ● ● ●
A401 EXTERIOR ELEVATIONS - BUILDING B ● ● ● ●
A402 EXTERIOR ELEVATIONS - BUILDING C ● ● ● ●
A500 BUILDING SECTIONS ● ● ● ●
A600 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING A ● ● ● ●
A601 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING A ● ● ● ●
A602 ENLARGED PLANS & INTERIOR ELEVATIONS - BUILDING B & C ● ● ● ●
Sheet Number Sheet Name D
D
D R
A F
T
C D
S
IG
N E
D A
N D
S E
A L
GENERAL
G000 COVER SHEET ● ● ● ●
G100 GENERAL INFORMATION AND ABBREVIATIONS ● ● ● ●
G200 GENERAL NOTES ● ● ● ●
G300 CODE MATRIX AND INFORMATION ● ● ● ●
G301 ACCESSIBLE UNIT PATH TRAVEL ● ●
G400 ACCESSIBILITY INFORMATION ● ● ● ●
G500 ASSEMBLY TYPES ● ● ● ●
CIVIL
C-1 NOTES & LEGEND ● ● ● ●
C-2 SURVEY CONTROL ● ● ● ●
C-3 SITE DISTURBANCE PLAN ● ● ● ●
C-4 OVERALL SITE PLAN ● ● ● ●
C-5 DEMOLITION PLAN ● ● ● ●
C-6 OVERALL UTILITY PLAN ● ● ● ●
C-7 OVERALL UTILITY PLAN ● ● ● ●
C-8 ADA ACCESSIBLE PATH PLAN ● ● ● ●
C-9 OVERALL GRADING PLAN ● ● ● ●
C-10 DETAILED GRADING PLAN ● ● ● ●
C-11 DETAILED GRADING PLAN ● ● ● ●
C-12 DETAILED GRADING PLAN ● ● ●
C-13 DETAILED GRADING PLAN ● ● ●
C-14 DETAILED GRADING PLAN ● ● ●
C-15 DETAILED GRADING PLAN ● ● ●
C-16 DETAILED GRADING PLAN ● ● ●
C-17 PARKING & SIDEWALK GEOMETRIC PLAN ● ● ●
C-18 STORM PIPE PLAN & PROFILE (IN2 TO OUTLET) ● ● ●
C-19 STORM PIPE PLAN & PROFILE (IN4 TO OUTLET) ● ● ●
C-20 FOUNDATION DRAIN PLAN & PROFILE ● ● ●
C-21 SANITARY SEWER SERVICE PLAN & PROFILE ● ● ●
C-22 WATER SERVICE PLAN ● ● ●
C-23 WATER SERVICE PLAN ● ● ●
C-24 GENERAL DETAILS ● ● ●
C-25 GENERAL DETAILS ● ● ●
C-26 GENERAL DETAILS ● ● ●
C-27 STORMWATER DETAILS ● ● ●
C-28 CLIN 7 SITE DISTURBANCE PLAN ● ● ●
C-29 CLIN 7 OVERALL SITE PLAN ● ● ●
C-30 CLIN 7 DEMOLITION PLAN ● ● ●
C-31 CLIN 7 OVERALL UTILITY PLAN ● ● ●
C-32 CLIN 7 OVERALL GRADING PLAN ● ● ●
C-33 CLIN 7 DETAILED GRADING PLAN ● ● ●
C-34 CLIN 7 DETAILED GRADING PLAN ● ● ●
C-35 CLIN 7 STORM PIPE PLAN & PROFILE (IN5 TO IN4) ● ●
C-36 CLIN 7 DETAILS ● ●
C-37 CLIN 8 SITE DISTURBANCE PLAN ● ●
C-38 CLIN 8 OVERALL SITE PLAN ● ●
C-39 CLIN 8 DEMOLITION PLAN ● ●
C-40 CLIN 8 OVERALL UTILITY PLAN ● ●
C-41 CLIN 8 OVERALL GRADING PLAN ● ●
C-42 CLIN 8 DETAILED GRADING PLAN ● ●
C-43 CLIN 8 DRAINAGE PLAN GEOMETRIC PLAN ● ●
C-44 CLIN 8 STORM PIPE PLAN & PROFILE ● ●
C-45 CLIN 8 DETAILS ● ●
UNIT MIX & AREA CALCULATIONS
Level Area Name Occupancy Type Type
GROUND FLOOR 1631 SF BLDG A Single family dwelling unit under the IRC 2021Single family dwelling unit under the IRC 2021
3 BEDROOMS - 2 BATHROOMS
GROUND FLOOR 2548 SF BLDG B IRC FOR SF bldg. and family unit under the IRC 2021 1 UNIT - 2 BEDROOMS - 2 BATHROOMS
1 ACCESSIBLE - 2 BEDROOMS - 2 BATHROOMS STORAGE
GROUND FLOOR 3163 SF BLDG C R-2 Occupancy per IBC 2021 (more than 2 units) 2 UNIT - 2 BEDROOMS - 2 BATHROOMS
1 ACCESSIBLE - 1 BEDROOM - 1 BATHROOM STORAGE
Grand total 7343 SF
HM HOLLOW METAL
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
I
INSUL INSULATION / INSULATED
INT INTERIOR
IRGWB IMPACT RESISTANT GYPSUM WALLBOARD
L
LAV LAVATORY
M
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MRGWB MOISTURE-RESISTANT GYPSUM WALL BOARD
MTD MOUNTED
MTL METAL
N
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
O
OC ON CENTER
OH OPPOSITE HAND
OZ OUNCE
P
PCC PRE-CAST CONCRETE
PLUMB PLUMBING
PNT PAINT/PAINTED
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
R
R RADIUS
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCED
REQD REQUIRED
RM ROOM
S
SF SQUARE FOOT
SIM SIMILIAR
SOG SLAB ON GRADE
SPEC SPECIFIED OR SPECIFICATION
SPK SPRINKLER
SQ SQUARE
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION COEFFICIENT
STL STEEL
STRUCT STRUCTURAL
T
T&G TONGUE & GROOVE
T/ TOP OF
T/D TELEPHONE/DATA
TELE TELEPHONE
TLT TOILET
TOC TOP OF CONCRETE
TOS TOP OF STEEL / STRUCTURE
TOW TOP OF WALL
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VIF VERIFY IN FIELD
VP VISION PANEL
W
W/ WITH
WD WOOD
WWF WELDED WIRE FABRIC
A
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
B
BSMT BASEMENT
BTTM/ BOTTOM OF
C
C/C CENTER TO CENTER
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
D
DBL DOUBLE
DEMO DEMOLISH
DIA DIAMETER
DIMS DIMENSIONS
DN DOWN
DTL DETAIL
DWG DRAWING
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR / ELEVATION
EPDM ETHYLENE PROPYLENE DIENE ROOFING
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
F
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISHED FLOOR ELEVATION
FG FIBERGLASS
FIN FINISH
FLR FLOOR
FND FOUNDATION
FO FACE OF
FTG FOOTING
G
GA GAUGE
GALV GALVANIZED
GWB GYPSUM WALL BOARD
H
HC HOLLOW CORE
SYMBOLS
ABBREVIATIONS
BUILDING #A - SINGLE FAMILY
1 STORY
1 ACCESSIBLE UNIT - 3 BEDROOMS - 2 BATHROOMS
BUILDING #B - MULTI FAMILY
1 STORY
1 UNIT - 2 BEDROOMS - 2 BATHROOMS
1 ACCESSIBLE - 2 BEDROOM - 2 BATHROOM
1 STORAGE ROOM
4 BEDROOMS (TOTAL)
BUILDING #C - MULTI FAMILY
1 STORY
2 UNIT - 2 BEDROOMS - 2 BATHROOMS
1 ACCESSIBLE - 1 BEDROOM - 1 BATHROOM
1 STORAGE ROOM
5 BEDROOMS (TOTAL)
BUILDING CODES
MATERIAL DESIGNATIONS
DESIGN INTENT STATEMENT GENERAL NOTES HAZARDOUS MATERIALS
HISTORICAL SIGNIFICANCE
HISTORIC TREATMENT STANDARD
1. WORK OF THIS SECTION SHALL BE GOVERNED BY THE
CONTRACT DOCUMENTS. PROVIDE MATERIALS, LABOR,
EQUIPMENT, AND SERVICES NECESSARY TO FURNISH,
DELIVER, AND INSTALL THE WORK OF THIS SECTION AS
SHOWN ON THE DRAWINGS, AS SPECIFIED HEREIN, AND/OR
AS REQUIRED BY JOB CONDITIONS.
2. REPLACE THE OBSOLETE HOUSING UNITS:
• ABATE AND REMOVE EXISTING MISSION 66 HOUSING
UNITS.
• INSTALL (3) NEW HOUSING UNITS.
1. SINGLE FAMILY HOUSING UNIT
2. (2) 2 BEDROOM UNITS AND STORAGE
3. (2) 2 BEDROOM UNITS, (1) 1 BEDROOM UNITS
AND STORAGE.
• UTILITIES TO BE ROUTED TO NEW HOUSING UNITS.
• STORMWATER MITIGATION PLAN
1. BASE OPTION: COLLECT AND CONVEY
STORMWATER FLOWS SAFELY AWAY FROM THE
PROPOSED HOUSING.
2. OPTION 3: UPSTREAM SURFACE WATER
COLLECTION AND CONVEYANCE STRUCTURES
TO FURTHER REDUCE NUISANCE FLOWS AND
EROSION ACROSS THE SITE.
1. VERIFY THAT EXISTING CONDITIONS ARE AS INDICATED ON
THE DRAWINGS. NOTIFY THE CONTRACTING OFFICER,
PROJECT MANAGER, AND PARK SUPERINTENDENT
IMMEDIATELY OF VARIATIONS OR DISCREPANCIES THAT HAVE
THE POTENTIAL TO AFFECT THE WORK. DO NOT PROCEED
WITH AFFECTED WORK UNTIL VARIATIONS OR
DISCREPANCIES ARE FULLY RESOLVED IN CONSULTATION
WITH THE CONTRACTING OFFICER, PROJECT MANAGER, AND
PARK SUPERINTENDENT.
1.1 VISIT THE SITE TO DETERMINE BY INSPECTION ALL
EXISTING CONDITIONS, INCLUDING ACCESS TO THE SITE, THE
NATURE OF STRUCTURES, OBJECTS AND MATERIALS TO BE
ENCOUNTERED, AND ALL OTHER FACTS CONCERNING OR
AFFECTING THE WORK. INFORMATION AS DRAWN SHOWS
EXISTING CONDITIONS FOR INFORMATION ONLY AND DOES
NOT CONSTITUTE A GUARANTEE THAT OTHER ITEMS MAY NOT
BE FOUND OR ENCOUNTERED.
1.2 BEFORE STARTING WORK, MAKE A THOROUGH
EXAMINATION OF THOSE PORTIONS OF THE SITE IN WHICH
THE WORK IS TO BE PERFORMED. CHECK THE WORK
ADJOINING OR AT UNDERLYING LOCATIONS, IN WHICH THE
WORK IS TO BE PERFORMED. REPORT TO THE CONTRACTING
OFFICER, PROJECT MANAGER, AND PARK SUPERINTENDENT
ANY AND ALL CONDITIONS WHICH MAY INTERFERE WITH OR
OTHERWISE AFFECT OR PREVENT THE PROPER EXECUTION
AND COMPLETION OF THE WORK. DO NOT START THE WORK
UNTIL SUCH CONDITIONS HAVE BEEN EXAMINED AND A
COURSE OF ACTION MUTUALLY AGREED UPON.
1.3 THE EXECUTION OF WORK CONSTITUTES ACCEPTANCE
OF THE CONDITIONS. LATER CLAIMS WILL NOT CONSTITUTE
RELIEF FROM THE REQUIREMENTS OF THE SPECIFICATIONS
UNDER THIS SECTION, NOR WILL EXTRA COMPENSATION BE
PAID.
2. THE CONTRACTOR SHALL RECOGNIZE THAT ALL ASPECTS
AND ELEMENTS OF THE PROPERTY MAY POTENTIALLY
CONTRIBUTE TO THE HISTORIC SIGNIFICANCE, AND THE
CONTRACTOR SHALL NOT BE THE JUDGE OF THE RELATIVE
SIGNIFICANCE OF ANY FEATURE. THIS JUDGMENT IS ENTIRELY
THE RESPONSIBILITY OF THE CONTRACTING OFFICER,
PROJECT MANAGER, AND PARK SUPERINTENDENT.
CONSEQUENTLY, NO ELEMENT SHALL BE ALTERED, REMOVED,
DISPOSED OF OR TAKEN FROM THE PREMISES WITHOUT THE
APPROVAL OF THE CONTRACTING OFFICER, PROJECT
MANAGER, AND PARK SUPERINTENDENT AS BEING
CONSISTENT WITH THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS.
2.1 ACTIVITIES THAT INVOLVE DEMOLITION, DISASSEMBLY,
OR SELECTIVE REMOVAL OF MATERIAL CAN RESULT IN
PERMANENT LOSS IF CARE IS NOT TAKEN TO AVOID SUCH
DAMAGE. APPROPRIATE PROCEDURES AND TECHNIQUES
FOR STORAGE OF DISASSEMBLED ITEMS MUST BE TAKEN
INTO ACCOUNT AS SPECIFIED BEFORE THE WORK
COMMENCES.
3. PROTECT AND PREVENT DAMAGE TO ALL HISTORIC BUILDING
AND HISTORIC SITE RESOURCES. NOTIFY CONTRACTING
OFFICER, PROJECT MANAGER, AND PARK SUPERINTENDENT
IMMEDIATELY IF ACCESS, TRANSPORT OF MATERIALS, OR ANY
ASPECT OF THE WORK HAS THE POTENTIAL TO CAUSE
DAMAGE TO HISTORIC RESOURCES. DO NOT PROCEED WITH
AFFECTED WORK UNTIL POTENTIALLY-DAMAGING ACTIONS
ARE FULLY RESOLVED IN CONSULTATION WITH THE
CONTRACTING OFFICER, PROJECT MANAGER, AND PARK
SUPERINTENDENT.
4. PERFORM ALL CONSTRUCTION AND INSTALLATION WORK
SHOWN IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES
AND ORDINANCES. USE METHODS AS REQUIRED TO
COMPLETE WORK WITHIN LIMITATIONS OF ALL PREVAILING
CODES AND LAWS.
5. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS IN THE FIELD. DIMENSIONS SHOWN AT
EXISTING CONDITIONS ARE TO FACE OF EXISTING FINISH
UNLESS NOTED OTHERWISE.
6. SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL
BE SOLELY RESPONSIBLE FOR THE CONDITIONS AT THE JOB
SITE, INCLUDING SAFETY OF PEOPLE AND PROPERTY.
7. INSTALL MANUFACTURED MATERIALS AND EQUIPMENT PER
MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS,
UNLESS OTHERWISE INSTRUCTED.
8. ALL WASTE GENERATED BY THE WORK SHALL BE REMOVED
FROM THE PREMISES AND LEGALLY DISPOSED OF BY THE
CONTRACTOR INCLUDING HAZARDOUS MATERIALS.
HAZARDOUS MATERIAL DISPOSAL MUST BE DOCUMENTED
AND LEGAL DISPOSAL PERMITS SUBMITTED FOR RECORD.
THE PREMISES SHALL BE LEFT CLEAR AND CLEAN TO THE
SATISFACTION OF THE CONTRACTING OFFICER.
9. APPLICATION OF FINISH: SURFACES PREVIOUSLY PREPARED
OR INSTALLED BY ANOTHER TRADE SHALL BE INSPECTED
CAREFULLY BY THE CONTRACTOR BEFORE APPLYING
SUBSEQUENT MATERIALS OR FINISHES. IF SURFACES ARE
NOT ACCEPTABLE, IMMEDIATELY NOTIFY THE CONTRACTING
OFFICER SO THAT CORRECTIONS MAY BE MADE. DO NOT
APPLY FINISHES TO SUBSTRATES THAT ARE NOT
ACCEPTABLE.
1. WORK OF THIS SECTION SHALL BE GOVERNED BY THE
CONTRACT DOCUMENTS. PROVIDE MATERIALS, LABOR,
EQUIPMENT, AND SERVICES NECESSARY TO FURNISH,
DELIVER, AND INSTALL THE WORK OF THIS SECTION AS
SHOWN ON THE DRAWINGS, AS SPECIFIED HEREIN, AND/OR
AS REQUIRED BY JOB CONDITIONS.
1. THIS SITE OF THIS PROJECT IS CHACO CULTURE NATIONAL
HISTORICAL PARK (CHCU). THE PARK IS A MAJOR CENTER
OF ANCESTRAL PUEBLO CULTURE. THE SITE CONTAINS THE
LARGEST, BEST PRESERVED AND MOST COMPLEX
PREHISTORIC ARCHITECTURAL STRUCTURES IN NORTH
AMERICAN. ALL GROUND SURFACES AND FEATURES
SHOULD BE TREATED AS ARCHEOLOGICALLY SENSITIVE
AND NO DISTURBANCE OF ARCHEOLOGICAL RESOURCES
SHALL BE ALLOWED.
2. CHACO CULTURE NATIONAL HISTORICAL PARK IS LISTED IN
THE NATIONAL REGISTER OF HISTORIC PLACES AND WAS
DESIGNATED AS A UNESCO WORLD HERITAGE SITE IN 1987.
THE PARK IS AFFORDED PROTECTION UNDER SECTION 110
OF THE NATIONAL HISTORIC PRESERVATION ACT.
3. AS A NATIONAL HISTORICAL PARK, SITE SENSITIVE
ARCHEOLOGICAL RESOURCES AND HISTORIC SITE, ALL
WORK MUST BE CONDUCTED BY THE CONTRACTOR IN A
MANNER THAT PRIORITIZES PROTECTION OF HISTORIC
RESOURCES DURING CONSTRUCTION. THE WORK WILL
REQUIRE USING MEANS AND METHODS CAREFULLY
SELECTED TO BE LEAST DAMAGING TO CHACO CANYON
AND THE SURROUNDING SITE. MEANS AND METHODS ARE
CONSTRAINED TO THOSE THAT WILL AFFORD THE SITE
PROTECTION AGAINST DAMAGE OF ANY KIND.
1. THE WORK OF THIS PROJECT IS TO BE CONDUCTED IN A
MANNER CONSISTENT WITH "THE SECRETARY OF THE
INTERIOR'S STANDARDS FOR THE TREATMENT OF HISTORIC
PROPERTIES."
2. RECONSTRUCTION IS THE TREATMENT STANDARD TO BE
APPLIED TO THE WORK OF THIS PROJECT.
10. INSTALL WORK PLUMB, LEVEL AND STRAIGHT, OR AS
REQUIRED TO ALIGN WITH EXISTING HISTORIC SURFACES
TO REMAIN.
11. CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS
REQUIRED TO PERFORM WORK. RESPONSIBILITY FOR
ENGINEERING, CONSTRUCTION, AND SAFETY OF THE
SHORING SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
12. CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE
DRAWINGS, SPECIFICATIONS, NOTES AND DETAILS SHALL
BE BROUGHT TO THE ATTENTION OF THE CONTRACTING
OFFICER AND RESOLVED BEFORE PROCEEDING WITH
WORK.
13. DETAILS SHOWN SHALL BE INCORPORATED INTO THE
PROJECT AT ALL APPROPRIATE LOCATIONS WHETHER
SPECIFICALLY CALLED OUT OR NOT.
14. THE CONTRACTING OFFICER, PROJECT MANAGER, AND
PARK SUPERINTENDENT IS TO HOLD A TOUR OF THE
PROPERTY PRIOR TO DEMOLITION FOR ALL PROJECT
MANAGERS, SUPERVISORS, SUPERINTENDENTS, OR
FOREMEN (PLUS ANY INTERESTED WORKERS) OF EACH
CONTRACTOR AND SUBCONTRACTOR.
15. THE CONTRACTOR WILL COMPLY WITH ALL SECURITY
RULES AND POLICIES OF THE PARK AND CONTRACTING
OFFICER, PROJECT MANAGER, AND PARK
SUPERINTENDENT AND SHALL INCLUDE ALL COSTS
ASSOCIATED WITH COMPLIANCE.
16. ALL ON-SITE PERSONNEL ARE EXPECTED TO CONDUCT
THEIR OPERATIONS IN A PROFESSIONAL MANNER AND BE
COURTEOUS AND POLITE TO ALL VISITORS.
17. WORKMANSHIP - EMPLOY ONLY COMPETENT WORKERS
THOROUGHLY SKILLED IN THEIR RESPECTIVE TRADES TO
PERFORM THE WORK. THE WORK SHALL BE PERFORMED
BY COMPETENT WORKERS EXPERIENCED IN THIS KIND OF
WORK AND SHALL BE CARRIED THROUGH TO COMPLETION.
REFERENCE SPECIFICATIONS FOR EXACT QUALIFICATIONS.
18. PERFORM THE WORK IN ACCORDANCE WITH THE HIGHEST
STANDARDS AND ESTABLISHED PRACTICES IN THE TRADE,
AND CONFORM TO ALL THE RULES AND REGULATIONS OF
ALL FEDERAL AUTHORITIES HAVING JURISDICTION OVER
THIS WORK.
19. CONTRACTOR TO PROTECT GROUND SURFACES ADJACENT
TO WORK. REPAIR TURF AND ADJACENT SURFACES TO
PRE-PROJECT CONDITIONS. ALL DIGGING SHALL BE
APPROVED BY THE PARK PRIOR TO THE WORK.
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024 IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
UM
EN
TS
:4 :4
P
MB
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n yo n .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
GENERAL NOTES
G200 10/10/2024 003 of 155
FD
FD
FD
FD
FD
FD
FD
FD
FD
1,631 SF/
200 SF/OCC
8 OCC
BUILDING TOTAL:
8 OCCUPANTS
MAX EXIT DISTANCE 73' 3"
MAX ALLOWABLE DISTANCE = 75'
1060 SF/
200 SF/OCC
6OCC
BUILDING TOTAL:
10 OCCUPANTS
MAX EXIT DISTANCE 55' 6"
MAX ALLOWABLE DISTANCE = 75'
547 SF/
200 SF/OCC
3 OCC
1060 SF/
200 SF/OCC
6 OCC
55'6"
BUILDING TOTAL:
12 OCCUPANTS
MAX EXIT DISTANCE 55' 6"
MAX ALLOWABLE DISTANCE = 75'
1060 SF/
200 SF/OCC
6 OCC
CODE PLAN LEGEND
EMERGENCY EGRESS
PATH (34" MIN. WIDE)
TRAVEL DISTANCE
OCCUPANTS AT EXIT
OCCUPANT
TOTAL SF
XX' - XX"
X
OCC
XX SF
BUILDING A CODE SUMMARY
NOTE: PRELIMINARY ANALYSIS BASED ON 2021 INTERNATIONAL RESIDENTIAL CODE.
PROJECT DESCRIPTION:
THIS PROJECT INCLUDES THE PLANS FOR BUILDING # A, A SINGLE FAMILY DWELLING,
SINGLE STORY BUILDING WITH 3 BEDROOMS, 2 BATHROOMS, AND INTERCHANGEABLE
BUILDING COMPONENT OPTIONS.
PROJECT ADDRESS: TBD
BUILDING CODE EDITION:
(PRE-REQUIRED BY JURISDICTION)
2021 INTERNATIONAL RESIDENTIAL CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE
ANSI A 117.1 - 2017
ABAAS 2015
CONSTRUCTION TYPE: V-B, SPRINKLER
PROPOSED: HEIGHT STORIES AREA
20 FT MAX 1 1,631SF
BUILDING B CODE SUMMARY
NOTE: PRELIMINARY ANALYSIS BASED ON 2021 INTERNATIONAL RESIDENTIAL CODE.
PROJECT DESCRIPTION:
THIS PROJECT INCLUDES THE PLANS FOR BUILDING #B, A SINGLE FAMILY DWELLING,
SINGLE STORY BUILDING WITH 2 UNITS, EACH WITH 2 BEDROOMS, 2 BATHROOMS,
AND INTERCHANGEABLE BUILDING COMPONENT OPTIONS.
PROJECT ADDRESS: TBD
BUILDING CODE EDITION:
(PRE-REQUIRED BY JURISDICTION)
2021 INTERNATIONAL RESIDENTIAL CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE
ANSI A 117.1 - 2017
ABAAS 2015
CONSTRUCTION TYPE: V-B, SPRINKLER
PROPOSED: HEIGHT STORIES AREA
20 FT MAX 1 2,548 SF
BUILDING C CODE SUMMARY
NOTE: PRELIMINARY ANALYSIS BASED ON 2021 INTERNATIONAL BUILDING CODE.
PROJECT DESCRIPTION:
THIS PROJECT INCLUDES THE PLANS FOR BUILDING #C, A SINGLE FAMILY DWELLING,
SINGLE STORY BUILDING WITH 2 UNITS, EACH WITH 2 BEDROOMS, 2 BATHROOMS,
AND ONE ACCESSIBLE UNIT WITH 1 BEDROOM, 1 BATHROOM.
PROJECT ADDRESS: TBD
BUILDING CODE EDITION:
(PRE-REQUIRED BY JURISDICTION)
2021 INTERNATIONAL BUILDING CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE
ANSI A 117.1 - 2017
ABAAS 2015
CONSTRUCTION TYPE: V-B, SPRINKLER
PROPOSED: HEIGHT STORIES AREA
20 FT MAX 1 3,163 SF
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS PER TABLE R302.1(2)
BUILDING ELEMENT FIRE RESISTANCE RATING (HOURS)
PRIMARY STRUCTURAL FRAME
BEARING WALLS - EXTERIOR
BEARING WALLS - INTERIOR
NON-BEARING WALLS - INTERIOR
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS PER TABLE R302.1(1)
SEPARATION DISTANCE (FEET) FIRE RESISTANCE RATING (HOURS)
X < 5 5 ≤ X < 10 10 ≤ X < 30 10 ≤ X < 30
FIRE DETECTION AND SUPPRESSION NFPA 13R SYSTEM OR INSTALLED IN ACCORDANCE
WITH SECTION P2904.
FIRE ALARM SYSTEM
SMOKE DETECTION SYSTEM
SPRINKLER SYSTEM
STANDPIPE SYSTEM
CARBON MONOXIDE DETECTORS
FIRE EXTINGUISHERS AND CABINETS
REQUIRED
NO
YES
YES
NO
YES
NO
PROVIDED
NO
YES
YES
NO
YES
YES
GENERAL NOTES:
1. ALL BUILDING PLANS SHALL MEET NPS-DSC WORKFLOW REQUIREMENTS.
2. ALL BUILDINGS SHALL MEET ACCESSIBILITY REQUIREMENTS OUTLINED IN THE
ARCHITECTURAL BARRIERS ACT (ABAAS) STANDARDS.
3. ALL BUILDINGS SHALL MEET LOCAL CODE REQUIREMENTS.
4. SEE A8 FOR ACCESSIBILITY COMPLIANCE PLANS AND INTERIOR ELEVATIONS
BUILDING A AND B CODE REVIEW: IRC 2021
Section R302 Fire-resistant construction
R302.1 Exterior Walls:
Table 302.1(2): For buildings with fire suppression:
Walls: 0 HR rating if Fire Separation distance is greater than 3 ft.
Projections: 0 HR rating if Fire Separation distance is greater than 3 ft.
Openings in Walls: 0 HR rating and unlimited in area if Fire Separation distance is greater than 3 ft.
Penetrations: Comply with R302.4 if less than 3 ft.
R302.2 Townhomes:
Common wall between two townhomes to be constructed without plumbing or mechanical equipment, ducts, or vents in the cavity of the common wall. The wall must be rated for fire exposure on both sides and be constructed tight to the underside of the roof sheathing.
1. If sprinklers are installed: common wall may be 1 HR rated.
R302.2.2 Common Walls:
Common walls separating townhouse units shall be assigned a fire-resistance rating in accordance with item 1 and shall be rated for fire exposure from both sides.
Exception: Common walls are permitted to extend to and be tight against the exterior walls if the cavity between the end of the common wall and the exterior sheathing is filled with a minimum of 2-inch nominal wood studs.
R302.2.3 Continuity The fire-resistance-rated wall or assembly separating TH units shall be continuous from the foundation to the underside of the roof sheathing, deck, or slab. The FR rating shall extend the full length of the wall, including wall extension through enclosed accessory structures.
R302.2.4 Parapets for townhouses Exception: Parapet is not required where roof covering complies with a minimum Class C rating (per ASTM E 108 or UL 790), and the roof sheathing is of a noncombustible material or approved fire-retardant treated wood deck extends for a distance of 4 feet on each side of the common wall. Option:
5/8” Type X installed below the roof deck. Roof penetrations not allowed within 4 feet from the common wall (if no parapet).
R302.11 Fire blocking Required to cut off both vertical and horizontal draft openings, provide in the following locations:
1. Vertically at the ceilings and floors of stud walls
2. Horizontally not exceeding 10 feet
3. At intersections of concealed vertical and horizontal spaces such as soffits, cove ceilings
4. At openings around vents, pipes and ducts, cables and wires at ceiling and floor levels with an approved material. Material meeting the requirements shall not be required to meet ASTM E136 requirements.
R302.12 Draftstopping Draftstops shall be installed so the area of the concealed space (where there is usable space above and below) does not exceed 1,000 SF. Draft stopping shall divide the space into approximately equal areas.
Where the assembly is enclosed by a floor membrane above and a ceiling membrane below, draft stopping shall be provided in the floor-ceiling assemblies under the following circumstances:
1. Ceiling is suspended under the floor framing.
2. Floor framing is constructed of truss-type open web or perforated members.
Section R310 Emergency escape and rescue openings Every sleeping room shall have at least one operable emergency escape opening.
R310.1.1 Window opening control devices (fall protection) complying with ASTM F2090 shall be permitted for use on windows serving as a required emergency escape and rescue opening and shall not be more than 70 inches above the finished floor.
R310.2.1. Minimum opening area Minimum clear opening of 5.7 SF required, a clear height of 24:” and clear width of 20” must be provided.
Ground floor emergency escape windows may be 5.0 SF in area.
R310.2.2: Window sill height Maximum window sill for escape openings is 44”
Section R313 Automatic Fire Sprinkler Systems Automatic sprinkler systems shall be installed in townhomes and designed in accordance with Section P2904 or NFPA 13D.
Section R314 Smoke Alarms:
Comply with NFPA 72 and Section R314, listed per UL 217, combination smoke/ carbon monoxide alarms shall be listed in accordance with UL 217 and UL 2034
R314.3 Locations
1. In each sleeping room
2. Outside each sleeping room in the immediate vicinity of the bedrooms
3. On each additional story including basements and habitable attics
4. Not less than 3 feet from a bathroom where the bathroom contains a tub or shower, unless this would prevent placement of a smoke alarm required by Section 314.3.
5. In the hallway and in the room open to the hallway in dwelling units where the ceiling height of the room open to the hallway serving bedrooms exceeds that of the hallway by 24 inches or more
R314.3.1 Installation near cooking appliances:
Smoke alarms shall not be installed in the following locations, unless this would prevent placement of a smoke alarm in a location required by Section 314.3:
1. Ionization smoke alarms shall not be installed within 20 feet of a permanently installed cooking device.
2. Ionization smoke alarms with alarm-silencing switch shall not be installed within 10 feet of a permanently installed cooking device.
3. Photoelectric smoke alarms shall not be installed less than 6 feet of a permanently installed cooking device.
4. Smoke alarms listed and marked “helps reduce cooking nuisance alarms” shall not be installed less than 6 feet of a permanently installed cooking device.
R314.4 Interconnection Where more than one smoke alarm is required, they must be interconnected so that the activation of one alarm will activate all of the alarms in the individual dwelling unit. Physical interconnection shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm
R314.7 Fire Alarm systems Fire alarms are permitted to be used in lieu of smoke alarms and shall comply with Sections R314.7.1 through R314.7.4
Section R315 Carbon Monoxide Alarms Listed per UL 2034
Combination smoke/ CO alarms shall be permitted in lieu of CO alarms.
R315.2 Where required (new construction), in dwelling units where either or both of these conditions exist:
1. The DU contains a fuel-fired appliance
2. The DU has an attached garage with an opening that communicates with the dwelling unit
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024
IS
SU
E
FO
R
FI
N
AL
C
ON
ST
RU
C
TI
O N
DO
C
UM
EN
TS
:1 :3
P M
B
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n y o n .r v t
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
CODE MATRIX AND
INFORMATIONG300
10/10/2024
1/8" = 1'-0"
GROUND FLOOR CODE PLAN - #A
1/8" = 1'-0"
GROUND FLOOR CODE PLAN - #B
1/8" = 1'-0"
GROUND FLOOR CODE PLAN - #C
0 4' 8' 16'
FD
FD
FD
FD
FD
FD
FD
FD
BEDROOM 3
BEDROOM 2 BEDROOM 1
HALL
BATH 2
BATH 1
LAUNDRY
W.H.
KITCHEN
LIVING ROOM
MECH
CLO.
CLO.
CLO.
CLO.
56' - 6"
57' - 7" 49' - 5"
8 FE
ACCESSIBLE UNIT
1526 SF
200 SF/OCC
TOTAL= 8 OCC
LIVING ROOM
BEDROOM 2
HALL
LAUNDRY
BATH 1
BATH 2
BEDROOM 1
KITCHEN
MECH/W.H.
CLO
CLO.
CLO.
CLO.
CLO.
42' - 0"
43' - 4"
32' - 8"
FE
ACCESSIBLE UNIT
981 SF
200 SF/OCC
TOTAL= 5 OCC
LIVING ROOM /
KITCHEN
BATH
HALL
LAUNDRY
MECH/ W.H
BEDROOM
35' - 7"3
FE
ACCESSIBLE UNIT
491 SF
200 SF/OCC
TOTAL= 3 OCC
CODE PLAN LEGEND
EMERGENCY EGRESS
PATH (34" MIN. WIDE)
TRAVEL DISTANCE
OCCUPANTS AT EXIT
OCCUPANT
TOTAL SF
XX' - XX"
X
OCC
XX SF
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024
IS
SU
E
FO
R
FI
N
AL
C
ON
ST
RU
C
TI
O N
DO
C
UM
EN
TS
:1 :1
P M
B
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n y o n .r v t
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
ACCESSIBLE UNIT PATH
TRAVELG301
10/10/2024
3/16" = 1'-0"
GROUND FLOOR - A
3/16" = 1'-0"
GROUND FLOOR - B
3/16" = 1'-0"
GROUND FLOOR - C
KEY SITE PLANA
B
C
NTS
MANUVERING CLEARANCES AT DOORS
Y
Y = 48" MIN.
Y = 54" MIN. IF DOOR HAS BOTH A
LATCH AND CLOSER
PULL SIDE PUSH SIDE
Y = 42" MIN.
Y = 48" MIN. IF DOOR HAS A
CLOSER
X = 36" MIN. IF Y = 60"
X = 42" MIN. IF Y = 54"
Y = 42" MIN.
Y = 48" MIN. IF DOOR HAS BOTH A
LATCH AND A CLOSER
W/ LATCH AND CLOSER
4'-0" MIN.
CLEARANCES FOR DOORS IN SERIES
7'-0" MIN.
4'-0" MIN.
24" MIN.
Y 60
M
IN
18" MIN.
24" PREFERRED
12" MIN.
M
IN
54" MIN.24" MIN.
PULL SIDE PUSH SIDE PUSH SIDEPULL SIDE
21" MAX.
M A
X H
T
A C
C E
S S
IB
LE
S T
O R
A G
E S
P A
C E
S
9" M
IN
M A
X
SHELVES
FROM CENTER
LINE OF SHELF
CLOTHES ROD
M A
X H
T
A C
C E
S S
IB
LE
S T
O R
A G
E S
P A
C E
S
M A
X
21" MAX.
STANDARD MOUNTING HEIGHTS
M
IN
M
IN
M
IN
C
LE
A
R A
N C
E
T .O
R
IM
M
A X
S U
R F
A C
E
B .O
R
E F
LE
C
T
IV
E
LAVATORIES ADJ. TO A WALL
SHALL BE MOUNTED 18" FROM ADJ.
WALL TO CENTERLINE OF FIXTURE
LAVATORYOUTLETSTOILET PAPER
DISPENSER
INSULATE ALL
EXPOSED
PIPING
LAVATORY CLEARANCE
CLEAR FLOOR SPACE
AT LAVATORY
M
IN
41" MIN.
17" MIN.
10" MAX.
PROTRUDING HAZARDS
4" MAX.
M
IN
. C
LE
A R
H
IG
H E
R T
H A
N
7"
O R
B E
LO
W
NO MAXIMUM
SIGNAGE MOUNTING HEIGHT
M A
X
8" MAX.
SIGN
1. MINIMUM 48" TO BOTTOM OF LOWER-MOST CHARACTERS
2. MAXIMUM 60" TO BOTTOM OF UPPER-MOST CHARACTERS
3. LOCATE BESIDE INACTIVE LEAF OF DOUBLE DOORS
4. 18" x 18" MINIMUM CLEAR FLOOR AREA BEYOND SWING
REQUIRED FOR SIGN
SCALE: NTS
SCALE: NTS
LEVEL CHANGES
1/ 2"
M A
X
THRESHOLD
1/ 4"
M A
X
M A
X
M
IN
M
IN
M A
X
6" MAX.8" MIN. 17" MIN.
67"
64" MIN
M
IN
M
IN
M
IN
11" MIN 42" MIN 11" MIN
CIRCULAR AND T-SHAPED 67" TURNING SPACE
Y
X
Y
BEGINNING OF
SLOPE
COMPLIANT THRESHOLD IN
BED OF SEALANT
DOOR AS SCHEDULED
OCCUPANCY SIDE HARDWARE AND DEVICES
FIRE ALARM AUDIO/VISUAL
DEVICES PER NFPA 72
AND ADA 702
6"
3'
O R
M A
T C
H E
X
IS
T
IN
G
M
IN
M
A X
T
O O
P E
R A
B
LE
P O
R T
IO
N
S P
E R
A D
A
.2
.7
CLUSTERED LIGHT
SWITCH, DIMMERS, ETC.
SEE PLAN FOR QUANTITY
AT EACH CLUSTER
A/V, SHADE CONTROLS,
ETC. WHERE
APPLICABLE
THERMOSTAT
CARBON DIOXIDE
SENSOR
6' -8
M
IN
8' -0
M
A X
T
O C
E N
T E
R O
F L
E N
S O
F S
T R
O B
E
1'
O R
M A
T C
H E
X
IS
T
P E
R A
D A
1'
M
IN
OUTLET(S) CENTERED ON
DEVICES U.N.O.
OVERLAP OF
KNEE AND TOE
CLEARANCE
CLEAR FLOOR SPACE
SCALE: NTS
52"
M A
X
TOILET ROOM ELEVATIONS
36" MIN. 6" MAX.
M
IN
36" MAX.
1"
12" MAX. 42" MIN.
39"- 41"
1 1/2" DIA. BAR TYP.
12" MIN.24" MIN.
M
IN
1' -5
M
IN
1' -7
M
A X
1' -5
M
IN
1' -7
M
A X
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024 IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
UM
EN
TS
:4 :4
P
MB
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n yo n .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
ACCESSIBILITY
INFORMATIONG400
10/10/2024 006 of 155
WOOD STUDS AT 16" O.C.
NOTE: FRAME METAL STUDS
AROUND UTILITIES. FIT GYP BD
AROUND UTILITIES, PIPING, ETC.,
SCHEDULED BASE, BOTH SIDES
ACOUSTIC SEALANT, BOTH
SIDES
SCHEDULED FLOOR
TYPICAL DEFLECTION
TRACK
BASE
PLAN
HEAD
PENETRATIONS, V.I.F.
SCHEDULED CEILING
5/8" TYPE X GYP BD, BOTH
SIDES
M
IN
UL
STC
R-VALUE
WALL
TYPE
STUD
TYPE
STUD
GAUGE
WALL
WIDTH
NOTES
C0a 2-1/2" 20 7-1/4"
CHASE WALL
2 1/2" SOUND ATTENUATED BATT
INSULATION WITHIN WALL AND
RUN TO STRUCTURE ABOVE
3 1/2" SOUND ATTENUATED BATT
INSULATION WITHIN WALL AND
RUN TO STRUCTURE ABOVE
WOOD STUDS AT 16" O.C.
NOTE: FRAME WOOD STUDS
AROUND UTILITIES. FIT GYP BD
AROUND UTILITIES, PIPING, ETC.,
SMOKE SEAL
SCHEDULED BASE, BOTH SIDES
FIRE SHIELD COMPOUND ,
BOTH SIDES
SCHEDULED FLOOR
5/8" GYP BD BOTH SIDES
SCHEDULED FINISH
SCHEDULED CEILING
BASE
PLAN
HEAD
UL
STC
R-VALUE
WALL
TYPE
STUD
TYPE
STUD
GAUGE
WALL
WIDTH
NOTES
P2a P2 P2c
2X4 2X6 2X4
4 3/4" 7-1/4"
4 1/4" GYP BD ONE SIDE
BOTTOM OF ROOF
3 1/2" SOUND ATTENUATED BATT
INSULATION WITHIN WALL AND
RUN TO STRUCTURE ABOVE
WOOD STUDS AT 16" O.C.
NOTE: FRAME WOOD STUDS
AROUND UTILITIES. FIT GYP BD
AROUND UTILITIES, PIPING, ETC.,
SMOKE SEAL
SCHEDULED BASE, BOTH SIDES
FIRE STOPPING COMPOUND
SCHEDULED FLOOR
5/8" GYP BD BOTH SIDES
SCHEDULED FINISH
SCHEDULED CEILING
UL
STC
R-VALUE
WALL
TYPE
STUD
TYPE
STUD
GAUGE
WALL
WIDTH
NOTES
U311
P2b 2X6 6-1/8" 2 WALLS 1' - 0 1/4"
BOTTOM OF ROOF
BASE
PLAN
HEAD
5/8" GYP BD BOTH SIDES
DEMISING LINE, 1" MIN AIR SPACE
BETWEEN WALLS. FIRE BLOCK AT
10' - 0" O.C. HORIZONTAL AND
VERTICAL.
FIRE STOPPING COMPOUND
BOTH SIDE
MINERAL WOOL FIRE
BLOCKING/SOUND ISOLATION
1" MIN AIRSPACE CLEAR BETWEEN
WALLS FIRE BLOCKED 3 1/2" SOUND ATTENUATED BATT
INSULATION WITHIN WALL AND
RUN TO STRUCTURE ABOVE
WOOD STUDS AT 16" O.C.
NOTE: FRAME WOOD STUDS
AROUND UTILITIES. FIT GYP BD
AROUND UTILITIES, PIPING, ETC.,
SMOKE SEAL
SCHEDULED BASE
FIRE SHIELD COMPOUND ,
BOTH SIDES
SCHEDULED FLOOR
5/8" GYP BD SCHEDULED FINISH
SCHEDULED CEILING
UL
STC
R-VALUE
WALL
TYPE
STUD
TYPE
STUD
GAUGE
WALL
WIDTH
NOTES
U407
P2b
P2d
2X6
2X6
6-1/8"
6-3/8" TILE ON BATHROOM
BOTTOM OF ROOF
BASE
PLAN
HEAD
WALL FINISH AS SCHEDULED
MTL. STUDS AT 16" O.C.
NOTE: FRAME METAL STUDS
AROUND UTILITIES.
SCHEDULED BASE
ACOUSTIC SEALANT
SCHEDULED FLOOR
DEFLECTION TRACK
5/8" GYP BD
SCHEDULED CEILING
PENETRATIONS, V.I.F.
BASE
PLAN
HEAD
ACOUSTIC SEALANT, BOTH
SIDES
UL
STC
R-VALUE
WALL
TYPE
STUD
TYPE
STUD
GAUGE
WALL
WIDTH
NOTES
P2e 2 1/2" 3" TILE ON BATHROOM
310250
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
ZC/DK
JW
ZC/SA
189893
EXP 12/31/2024 IS
SU
E
FO
R
FI
NA
L
C
ON
ST
RU
C
UM
EN
TS
:4 :4
P
MB
IM
N P S
C h a c o
N a ti o n a l P a rk
R e p la c e
O b s o le te
H o u s in g C h a c o
C a n yo n .r vt
CHACO NATIONAL PARK REPLACE
OBSOLETE HOUSING
ASSEMBLY TYPES
G500 10/10/2024
1 1/2" = 1'-0"C0 Chase wall
1 1/2" = 1'-0"P2a non-rated wd stud partition
1 1/2" = 1'-0"P2b
1-Hr rated wd stud demising partition
1 1/2" = 1'-0"P2d non-rated wd stud partition
1 1/2" = 1'-0"P2e Stud furring wall
LIST OF CIVIL SHEETS
BASE BID CIVIL SHEETS:
C-1 NOTES & LEGEND
C-2 SURVEY CONTROL
C-3 SITE DISTURBANCE PLAN
C-4 OVERALL SITE PLAN
C-5 DEMOLITION PLAN
C-6 & C-7 OVERALL UTILITY PLAN
C-8 ADA ACCESSIBLE PATH PLAN
C-9 OVERALL GRADING PLAN
C-10 - C-16 DETAILED GRADING PLAN
C-17 PARKING & SIDEWALK GEOMETRIC PLAN
C-18 STORM PIPE PLAN & PROFILE (IN2 to Outlet) C-19 STORM PIPE PLAN & PROFILE (IN4 to Outlet)
C-20 FOUNDATION DRAIN PLAN & PROFILE
C-21 SANITARY SEWER SERVICE PLAN & PROFILE
C-2 & C-23 WATER SERVICE PLAN
C-24 - C-26 GENERAL DETAILS
C-27 STORMWATER DETAILS
CLIN 7 CIVIL SHEETS:
C-28 CLIN 7 SITE DISTURBANCE PLAN
C-29 CLIN 7 OVERALL SITE PLAN
C-30 CLIN 7 DEMOLITION PLAN
C-31 CLIN 7 OVERALL UTILITY PLAN
C-32 CLIN 7 OVERALL GRADING PLAN
C-33 & C-34 CLIN 7 DETAILED GRADING PLAN
C-35 CLIN 7 STORM PIPE PLAN & PROFILE (IN5 to IN4)
C-36 CLIN 7 DETAILS
CLIN 8 CIVIL SHEETS:
C-37 CLIN 8 SITE DISTURBANCE PLAN
C-38 CLIN 8 OVERALL SITE PLAN
C-39 CLIN 8 DEMOLITION PLAN
C-40 CLIN 8 OVERALL UTILITY PLAN
C-41 CLIN 8 OVERALL GRADING PLAN
C-42 CLIN 8 DETAILED GRADING PLAN
C-43 CLIN 8 GEOMETRIC PLAN
C-44 CLIN 8 STORM PIPE PLAN & PROFILE
C-45 CLIN 8 DETAILS
CLIN 9 CIVIL SHEETS:
C-46 CLIN 9 SITE DISTURBANCE PLAN
C-47 CLIN 9 OVERALL SITE PLAN
C-48 CLIN 19 DEMOLITION PLAN
C-49 CLIN 9 OVERALL UTILITY PLAN
C-50 CLIN 9 OVERALL GRADING PLAN
C-51 CLIN 9 DETAILED GRADING PLAN
C-52 CLIN 9 DETAILED GRADING PROFILE
C-53 CLIN 9 GEOMETRIC PLAN
C-54 CLIN 9 STORM PIPE PLAN & PROFILE (IN6 to IN4)
C-55 & C-56 CLIN 9 DETAILS
SURVEY BOUNDARY
SECTION LINE
EASEMENT LINE
CHAIN LINK FENCE
OVERHEAD ELECTRIC
GAS LINE
UNDERGROUND ELECTRIC
GUARD RAIL
TELEPHONE LINE
FIBER OPTIC CABLE
EDGE OF WATER LINE/DITCH FLOWLINE
R.O.W. LINE
TREE LINE
WIRE FENCE
PROPERTY LINE
FORCE MAIN
SANITARY SEWER
STORM SEWER
PIPE UNDERDRAIN
WATER LINE
SETBACK LINE
TELEVISION LINE
UTILITY LINE
CONTOUR
CENTERLINE
WOOD FENCE
SILT FENCE
CONSTRUCTION LIMITS
LINETYPE LEGEND
PROPOSED EXISTING
FIRE WATER LINE
FIRE HOSE BOX
STORM MANHOLE
HYDRANT
WATER VALVE
GAS VALVE
STORM INLET
LIGHT POLE
SIGN
SPOT ELEVATION
MEASURED DIMENSION
REBAR WITH CAP #______, FOUND
P.K. NAIL, FOUND
CHISELED "X" IN CONCRETE, SET
CHISELED "X" IN CONCRETE, FOUND
REBAR, FOUND
SYMBOL LEGEND
1/2" SQ. PIN, FOUND
RECORDED DIMENSION
SECTION CORNER
R.O.W. MARKER, FOUND
CABLE TV PEDESTAL
ELECTRIC PEDESTAL/TRANSFORMER
TELEPHONE PEDESTAL
TELEPHONE POLE
FLARED END SECTION
SANITARY/STORM CLEANOUT
ELECTRIC MANHOLE
TELEPHONE MANHOLE
UTILITY MANHOLE
SPRINKLER HEAD
CONIFER TREE
DECIDUOUS TREE
TREE STUMP
BUSH/SHRUB
CONTROL POINT
UNKNOWN MANHOLE
GUY WIRE
POST/BOLLARD
5/8" REBAR WITH CAP #35-_____, SET
GAS METER
BENCHMARK
ELECTRIC METER
WATER METER
GUY POLE
GRADE LABEL
POWER POLE W/ LIGHT
POWER POLE W/ METER
DRAINAGE SLOPE
LINE CONTINUATION
SANITARY MANHOLE
CONCRETE MONUMENT, FOUND
PIPE, FOUND
P.K. NAIL, SET
SPRINKLER BOX
WATER MANHOLE
UTILITY MARKER
PROPOSED EXISTING
ADA STALL
AC ACRES
ASPH ASPHALT
B-B BACK TO BACK
BIT BITUMINOUS
BLDG BUILDING
BLVD BOULEVARD
BC BACK OF CURB
BRK BRICK
BW BOTTOM OF WALL
C&G CURB AND GUTTER
CL CENTERLINE
CONC CONCRETE
CY CUBIC YARD
Δ DELTA ANGLE
DC DEPRESSED CURB
DIA DIAMETER
DRV DRIVEWAY
E-E EDGE TO EDGE
EL/ELEV ELEVATION
EP EDGE OF PAVEMENT
EX EXISTING
FDN FOUNDATION
FF FINISH FLOOR
FL FLOWLINE
FS FINISH SURFACE
GRVL GRAVEL
GUT GUTTER
HP HIGH POINT
L LENGTH
LF LINEAL/LINEAR FEET
LP LOW POINT
LS LANDSCAPING
OC ON CENTER
PCC PORTLAND CEMENT CONCRETE
PR PROPOSED
PVMT PAVEMENT
R RADIUS
RD ROAD
RL REFERENCE LINE
RR RAILROAD
SF SQUARE FEET
SHLD SHOULDER
ST STREET
STD STANDARD
SW SIDEWALK
SY SQUARE YARD
TC TOP OF CURB
TEMP TEMPORARY
TW TOP OF WALL
TYP TYPICAL
UG UNDERGROUND
A/C ACCESS CONTROL
BM BENCHMARK
BSL BUILDING SETBACK LINE
PL PROPERTY LINE
POB POINT OF BEGINNING
POC POINT OF COMMENCING
ROW RIGHT OF WAY
SEC SECTION
UE UTILITY EASEMENT
ARCP ARCH DIA EQUIVALENT REINFORCED
CONCRETE PIPE
CMP CORRUGATED METAL PIPE
CPE CORRUGATED POLYETHYLENE PIPE
CPP CORRUGATED PLASTIC PIPE
CPVC CORRUGATED POLYVINYL CHLORIDE PIPE
DIP DUCTILE IRON PIPE
ERCP ELLIPTICAL REINFORCED CONCRETE PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
INV INVERT
PCCP PRESTRESSED CONCRETE CYLINDER PIPE
PVC POLYVINYL CHLORIDE PIPE
RCP REINFORCED CONCRETE PIPE
VCP VITRIFIED CLAY PIPE
CO CLEANOUT
FES FLARED END SECTION
FH FIRE HYDRANT
MH MANHOLE
SAN SANITARY
STM STORM
UTIL UTILITY
WM WATER MAIN
E EXTERNAL SECANT
OS OFFSET
PC POINT OF CURVATURE
PI POINT OF INTERSECTION OF HORIZONTAL
CURVE
PRC POINT OF REVERSE CURVATURE
PT POINT OF TANGENCY
STA STATION
T EXTERNAL TANGENT
VC VERTICAL CURVE
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
XSEC CROSS SECTION
ABBREVIATIONS
SURVEY
UTILITIES
PIPES
ALIGNMENT/PROFILE/XSECTIONS
IMEG CORP. HAS ADOPTED SAFETY PROCEDURES FOR ITS EMPLOYEES WHO PROVIDE
PROFESSIONAL ENGINEERING AND SURVEYING SERVICES. A COPY OF THESE
PROCEDURES IS AVAILABLE FROM THE SAFETY OFFICER. IMEG CORP. PERSONNEL
ARE NOT TRAINED IN CONTRACTOR (CONSTRUCTION) SAFETY AND COMPLIANCE
PROCEDURES. THE METHODS AND MEANS TO COMPLY WITH CONSTRUCTION SITE
SAFETY ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
UTILITY NOTE
THE LOCATIONS OF THOSE BURIED AND ABOVE GROUND UTILITIES SHOWN ARE APPROXIMATE, ARE SHOWN FOR CONTRACTOR INFORMATIONAL USE ONLY, AND ARE NOT TO BE REFERENCED FOR CONSTRUCTION PURPOSES. THE IMPLIED PRESENCE OR ABSENCE OF UTILITIES IS NOT TO BE CONSTRUED BY THE OWNER, ENGINEER, CONTRACTOR, OR SUBCONTRACTORS TO BE AN ACCURATE AND COMPLETE REPRESENTATION OF UTILITIES THAT MAY OR MAY NOT EXIST ON THE CONSTRUCTION SITE.
BURIED AND ABOVE GROUND UTILITY LOCATION, IDENTIFICATION, AND MARKING ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REROUTING, DISCONNECTION, PROTECTION, ETC. OF ANY UTILITY MUST BE COORDINATED BETWEEN THE CONTRACTOR, UTILITY COMPANY AND OWNER. SITE SAFETY, INCLUDING THE AVOIDANCE OF HAZARDS ASSOCIATED WITH BURIED AND ABOVEGROUND UTILITIES, REMAINS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
GENERAL NOTE
IF PREVIOUSLY UNKNOWN ARCHAEOLOGICAL RESOURCES ARE DISCOVERED DURING CONSTRUCTION, ALL WORK IN THE IMMEDIATE VICINITY (600 FEET) OF THE DISCOVERY SHALL BE HALTED UNTIL THE RESOURCES ARE IDENTIFIED AND DOCUMENTED AND AN APPROPRIATE MITIGATION STRATEGY DEVELOPED, IF NECESSARY, IN ACCORDANCE WITH PERTINENT LAWS AND REGULATIONS, INCLUDING THE STIPULATIONS OF THE 2008 PROGRAMMATIC AGREEMENT AMONG THE NATIONAL PARK SERVICE (U.S. DEPARTMENT OF THE INTERIOR), THE ADVISORY COUNCIL ON HISTORIC PRESERVATION, AND THE
NATIONAL CONFERENCE OF STATE HISTORIC PRESERVATION OFFICERS.
CONTACTS
IMEG - PROJECT MANAGER
TAYLOR GOERTZ, PE
7600 E ORCHARD RD., #250S,
GREENWOOD VILLAGE, CO 80111
303-647-4847
IMEG - CIVIL DESIGNER
PAIGE COUFAL
7600 E ORCHARD RD., #250S,
GREENWOOD VILLAGE, CO 80111
303-309-0464
C-1
NOTES & LEGEND
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
GAW, SEC
DATE:
DRAINAGE SWALE
ASPHALT PAVEMENT
STONE WALL
CONCRETE PAVEMENT
GRAVEL SURFACE
FLAGSTONE SURFACE
RIPRAP STONE
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
10/09/2024
GENERAL NOTES:
THIS SITE RESIDES IN THE S1/2 SECTION 21 AND THE N1/2 SECTION 28, TOWNSHIP 21 NORTH, RANGE
10W, NEW MEXICO PRIME MERIDIAN. NO PROPERTY BOUNDARY LINES ARE SHOWN. THIS
TOPOGRAPHIC SURVEY DOES NOT IN ANY WAY REPRESENT AN ACTUAL BOUNDARY SURVEY AND
SHOULD NOT BE RELIED UPON FOR ACCURATE BOUNDARY LOCATION.
UNDERGROUND UTILITY LOCATIONS SHOWN ARE BASED UPON VARIOUS RECORD UTILITY MAPS IN
CONJUNCTION WITH VISIBLE EVIDENCE GATHERED DURING THE FIELD SURVEY. THEREFORE
UNDERGROUND UTILITY LOCATIONS SHOULD BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
THIS DRAWING ONLY REFLECTS AND VERIFIES THE FIELD SURVEY DATA OF THOSE FEATURES AND
CONDITIONS PRESENT AS OF OCTOBER 2022.
HORIZONTAL DATUM: NM SPC NORTH ZONE NAD83(2011)
BASED ON NGS PID: GN0330 DESIGNATION: M 68
VERTICAL DATUM: NAVD 88 (GEOID 09)
BASED ON FHWA PID: BM E2 ELEVATION: 6207.98
C-2
SURVEY CONTROL
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-3
SITE DISTURBANCE PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
C-4
OVERALL SITE PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
DEMO NOTES
1. PROPANE METER ASSEMBLY TO BE REMOVED. TURN OVER METER TO OWNER. DEMOLISH BRANCH PIPING THAT IS THE INLET TO THE METER BACK TO MAIN PIPING IN THE GROUND. CAP BRANCH LINE WITHIN 4" FROM THE MAIN. VERIFY INTEGRITY OF CAP
CONNECTION WITH LEAK TEST. PIPING LOCATED ON THE DOWNSTREAM SIDE OF THE METER TO BE REMOVED WITH THE MISSION 66 STRUCTURE DEMOLITION. TYPICAL FOR EACH OF THE FOUR HOUSES BEING DEMOLISHED.
2. ELECTRICAL DEMOLITION OF EXISTING TRANSFORMERS AND METERS WILL BE COMPLETED BY THE SERVICE PROVIDER. THE CONTRACTOR SHALL REMOVE ALL UNISTRUT STANDS ASSOCIATED WITH THE EXISTING ELECTRICAL METERS AND THE EXISTING SERVICE
RUNNING FROM THE METER TO THE MISSION 66 HOUSING. TYPICAL FOR EACH OF THE FOUR HOUSES BEING DEMOLISHED.
3. REMOVE EXISTING POTABLE WATER SERVICE FROM THE HOUSE TO THE METER AND CAPPED. METER SHALL BE REMOVED AND TURNED OVER TO THE OWNER. CAP SHALL BE WATERRIGHT. TYPICAL FOR EACH OF THE FOUR HOUSES BEING DEMOLISHED.
3.1. FOR 2 INCH AND SMALLER SERVICE LINES, EXCAVATE THE SERVICE LINE CONNECTION WHERE THE CORPORATION STOP IS INSERTED INTO THE WATER MAIN. THE CORPORATION STOP SHALL BE CLOSED, THE SERVICE TUBING OR PIPING REMOVED FROM THE CORPORATION STOP, THE THREADS SCARRED ON THE CORPORATION STOP, AND A SECTION OF THE WATER SERVICE LINE AT LEAST 12 INCHES LONG CUT OUT. REMOVE THE CURB OR VALVE BOX OVER THE CURB STOP IN ITS ENTIRETY OR CUT IT OFF AT LEAST 18 INCHES BELOW THE GROUND LINE. REMOVE THE METER PIT IN ITS ENTIRETY, IF PRESENT. IF LEFT IN PLACE, CUT IT OFF AT LEAST 18 INCHES BELOW THE GROUND LINE AND FILL IT WITH SAND OR OTHER FILL MATERIAL.
3.2. FOR 3 INCH AND LARGER SERVICE LINES, EXCAVATE THE SERVICE LINE CONNECTION OVER THE SERVICE TEE ON THE WATER MAIN. REMOVE THE VALVE AT THE MAIN AND PLUG THE TEE OR TAP. REMOVE THE PROPERTY LINE VALVE BOX OR CUT IT OFF AT LEAST 18 INCHES BELOW THE GROUND LINE. REMOVE THE METER PIT IN ITS ENTIRETY, IF PRESENT. IF LEFT IN PLACE, CUT IT OFF AT LEAST 18 INCHES BELOW THE GROUND LINE AND FILL IT WITH SAND OR OTHER FILL MATERIAL.
3.3. CUT OFF POTABLE WATER TAPS AND CLEAN AND DISINFECT NEW FITTINGS IN ACCORDANCE WITH AWWA C651 WITH AN NSF 60 CERTIFIED SODIUM HYPOCHLORITE SOLUTION PRIOR TO INSTALLATION USING A SWAB OR SPRAY DISINFECTION METHOD. CAP THE PIPE WITH A PERMANENT BULKHEAD/BLIND FLANGE OR A TEMPORARY PNEUMATIC PLUG UNTIL THE INSTALLATION OF A PERMANENT CAP. PREVENT ENVIRONMENTAL CONTAMINATION (E.G., GROUND WATER, STORM WATER, ANIMALS, AND INSECTS)
FROM ENTERING THE POTABLE DISTRIBUTION SYSTEM AND/OR SERVICE LINE.
4. REMOVE EXISTING FIRE WATER PIPE FROM THE HOUSE TO THE MAIN PIPE AND CAP PIPE. CAP SHALL BE WATERTIGHT. TYPICAL FOR EACH OF THE FOUR HOUSES BEING DEMOLISHED. SEE NOTE 3 FOR ADDITIONAL INFORMATION.
5. REMOVE EXISTING SANITARY SEWER SERVICE FROM EXISTING HOUSING TO THE DOWNSTREAM CLEANOUT AND CAP PIPE (ON DOWNSTREAM SIDE OF CLEANOUT). CAP SHALL BE WATERTIGHT. TYPICAL FOR EACH OF THE FOUR HOUSES BEING DEMOLISHED.
6. REFER TO STRUCTURAL DEMOLITION PLANS FOR INFO ON FOUNDATION REMOVAL BELOW GRADE.
7. REFER TO ARCHITECTURAL PLANS FOR INFO ON MISSION 66 HOUSING DEMOLITION.
8. ALL STONE FROM EXISTING EXTERIOR WALLS AND PATIOS SHALL BE CAREFULLY DISASSEMBLED, CATALOGUED, SALVAGED, AND STORED FOR REINSTALLATION.
9. EXISTING MISSION 66 HOUSING SHALL BE DISASSEMBLED CAREFULLY.
10. DEMOLITION OF EXISTING PAVEMENT SHALL BE PHASED TO ALLOW CONTRACTOR USE OF PAVEMENT FOR STORAGE AND STAGING.
RESTORATION NOTES
1. EXCAVATED AREAS SHALL BE BACKFILLED TO REESTABLISH EXISTING GRADE.
2. DISTURBED AREAS SHALL BE SEEDED WITH THE APPROVED NATIVE SEED MIX TO REESTABLISH VEGETATION.
C-5
DEMOLITION PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
A
B
C
M A
TC
H
L
IN
E S
E E
S H
E E
T C
-7
C-6
OVERALL UTILITY PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
UTILITY NOTES
1. ALL DOMESTIC POTABLE WATER HEADER LINES SHALL BE 2" C900 PVC PIPING.
2. ALL DOMESTIC FIRE WATER HEADER LINES SHALL BE 3" C900 PVC PIPING.
3. ALL DOMESTIC POTABLE WATER SERVICE LINES SHALL BE 34" TYPE 'K' COPPER PIPING.
4. ALL DOMESTIC FIRE WATER SERVICE LINES SHALL BE 2" TYPE 'K' COPPER PIPING.
5. ALL SANITARY SEWER SERVICE LINES SHALL BE 3" PVC PIPING.
6. ALL STORMWATER PIPING SHALL BE ADS N-12 HDPE, ADS HP-STORM PP, OR APPROVED EQUIVALENT.
7. ALL STORMWATER MANHOLES SHALL 72"Ø BOX BASE MANHOLES WITH 24"Ø RING & COVERS.
8. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
9. ALL FOUNDATION DRAINS SHALL BE 6" PVC PIPING.
GAW, SEC
PREPARED BY
10/10/2024
IS
SUE FOR FIN
AL
CONSTRUCTIO
N
DOCUMENTS
40237
M
TC
H
L
IN
E S
E E
S H
E E
T C
-6
C-7
OVERALL UTILITY PLAN
CHACO CULTURE NATIONAL HISTORIC PARK
REPLACE OBSOLETE HOUSING
TITLE OF SHEETSUB SHEET NO. DRAWING NO.
189893
PMIS/PKG NO.
310350
SHEET
of
DESIGNED:
TCG/PRC
PRC
TECH. REVIEW:
DATE:
UTILITY NOTES
1. ALL DOMESTIC POTABLE WATER HEADER LINES SHALL BE 2" C900 PVC PIPING.
2. ALL DOMESTIC FIRE WATER HEADER LINES SHALL BE 3" C900 PVC PIPING.
3. ALL DOMESTIC POTABLE WATER SERVICE LINES SHALL…
This is the start of the file's text. The full file is on GovTribe.