This document is an Analysis Report from Schneider Laboratories Global, Inc. that provides the results of a Polarized Light Microscopy (PLM) analysis on three samples of composite shingle material collected from the Baker Beach location in San Francisco, California. The analysis found no asbestos present in any of the three samples, which consisted of layers of bituminous felt paper, mineral/glass wool, and non-fibrous material.

The related federal contract opportunity is for the Renewal of the Baker Beach Restroom Facility, a solicitation (140P8624R0022) issued by the Department of the Interior National Park Service Pacific West Region. The contract requires the refurbishment of a heavily used public restroom facility located in the Golden Gate National Recreation Area at Baker Beach.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attn:

Address: 35621 Beeching Lane Order #: 547481

Fremont, CA 94536

Advantage Environmental (2101)Customer:

Received 01/23/24

Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475

01/24/24Analyzed

01/24/24Reported

Analysis Report

PLM Analysis

Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials

EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method:

Project: Baker Beach

23-530Number:

Location: San Francisco CA

Felt Paper Comp Shingle01/18/24 011824-1547481-001

Black, Bituminous/Fibrous

Felt PaperLayer 1: No Asbestos Detected CELLULOSE FIBER55%

NON FIBROUS MATERIAL45%

Red/Black, Bituminous/Fibrous/Granular

Roof ShingleLayer 2: No Asbestos Detected

Sample was inhomogenous, subsamples of each component were analyzed separately.

MINERAL/GLASS WOOL20%

NON FIBROUS MATERIAL80%

Black, Bituminous

TarLayer 3: No Asbestos Detected NON FIBROUS MATERIAL100%

Felt Paper Comp Shingle01/18/24 011824-2547481-002

Black, Bituminous/Fibrous

Felt PaperLayer 1: No Asbestos Detected CELLULOSE FIBER55%

NON FIBROUS MATERIAL45%

Red/Black, Bituminous/Fibrous/Granular

Roof ShingleLayer 2: No Asbestos Detected

Sample was inhomogenous, subsamples of each component were analyzed separately.

MINERAL/GLASS WOOL20%

NON FIBROUS MATERIAL80%

Black, Bituminous

TarLayer 3: No Asbestos Detected NON FIBROUS MATERIAL100%

Felt Paper Comp Shingle01/18/24 011824-3547481-003

Black, Bituminous/Fibrous

Felt PaperLayer 1: No Asbestos Detected CELLULOSE FIBER55%

NON FIBROUS MATERIAL45%

Red/Black, Bituminous/Fibrous/Granular

No tar layer found.

Roof ShingleLayer 2: No Asbestos Detected

Sample was inhomogenous, subsamples of each component were analyzed separately.

MINERAL/GLASS WOOL20%

NON FIBROUS MATERIAL80%

Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. The test results apply to the sample as received.

PLM Analysis

Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials

EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method:

Project: Baker Beach

23-530Number:

Location: San Francisco CA

Microscopy Supervisor/Analyst

Reviewed By: Mohammed Hashim

Total layers analyzed on order: 8 547481-01/24/24 05:32 PM

EPA Regulatory Limit: 1%

Analyst Michael Alers

Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. The test results apply to the sample as received.