This is a Technical Information Form (Attachment 04) for RFQ No. 140P8426Q0079 issued by the National Park Service for the replacement of turbidity meters at Lake Creek Water Treatment Plant at Oregon Caves National Monument & Preserve. Quoters must submit business information including company name, address, UEI, phone, contact name, and signature. The form requires disclosure of whether the quoter plans to self-perform all work or utilize subcontractors, with detailed identification of any subcontractors and their assigned key trades, along with a description of work activities the quoter will self-perform.
The form mandates submission of relevant project experience with a minimum of three past performance references, including project title, contract number, agency/owner, contract amount, performance period, similarity description to the current requirement, and past performance reference contact information with phone and email. Quoters must certify whether their firm holds an Oregon Construction Contractors Board license, provide license details or proof of searchability, and confirm the same for any proposed subcontractors. Additionally, quoters must submit a technical approach narrative limited to ten pages addressing site assessment and mobilization plan, removal and demolition methodology, installation approach, testing and commissioning plan, quality assurance measures, personnel qualifications (specifically requiring confirmation that calibration/commissioning will be performed by a Hach-certified technician), general schedule, approach to minimizing service interruption, and optional Hach service plan details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B08_Att_03_140P8426Q0079_SCA_Wages.pdf | ||
| B08_Att_02_140P8426Q0079_Construction_Wages.pdf | ||
| B08_Att_05_140P8426Q0079_GenRefs.docx | DOCX document | |
| B08_Att_01_140P8426Q0079_Specs.pdf | ||
| Sol_140P8426Q0079.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL INFORMATION FORM
(Attachment 04)
Replace Turbidity Meters at Lake Creek Water Treatment Plant Oregon Caves National Monument & Preserve
RFQ No.: 140P8426Q0079
Quoters shall submit the following information:
Quoters Business Name: ___________________________________
Quoters Address: ___________________________________
Quoters UEI: ___________________________________
Quoters Phone: ___________________________________
Quoters Contact Name: ___________________________________
Quoters Signature: ___________________________________
CONTRACTOR’S PROPOSED TEAM:
Do you plan to self-perform all of the work? ___________________________
YES or NO answer
Are you proposing to use a subcontractor? ___________________________ YES or NO answer
List any proposed subcontractor(s) and indicate what key trade they may be assigned to perform:
Subcontractor Name Key Trade (Roofing, etc.)
If you are proposing to use a subcontractor, describe what work activities you plan to self-perform:
RFQ No. 140P8426Q0079, Attachment 04, Technical Information Form
LIST OF RELEVANT EXPERIENCE (LIST OF PROJECTS) & PAST PERFORMANCE REFERENCES:
1) Project Title: ___________________________ Contract # (if known): ______________
Agency/Owner: ___________________________ $ Amount: _______________________
Performance Period: ___________________________
Briefly describe how this project is similar in nature and scope to current advertised requirement:
Past Performance Reference (Name & Title): _______________________________________________
Phone Number: ___________________________ Email: __________________________
2) Project Title: ___________________________ Contract # (if known): ______________
Performance Period: ___________________________
Briefly describe how this project is similar in nature and scope to current advertised requirement:
3) Project Title: ___________________________ Contract # (if known): ______________
Performance Period: ___________________________
Briefly describe how this project is similar in nature and scope to current advertised requirement:
RFQ No. 140P8426Q0079, Attachment 04, Technical Information Form
OREGON CONTRACTOR STATE LICENSE:
Is your firm an Oregon Construction Contractors Board Contractor? ______________________ YES or NO answer ☐ license details/number: ______________________ ☐ proof of license is searchable online or include with your quote
IF you are proposing to use a subcontractor for any of the work:
Is subcontractor an OR Construction Contractors Board Contractor? _______________________ YES or NO answer ☐ license details/number: ______________________ ☐ proof of license is searchable online or include with your quote
TECHNICAL APPROACH
☐ Submit a brief written narrative limited to 10 pages describing your general technical approach to successfully accomplish this project (use separate pages as necessary).
NARRATIVE – Address site assessment and mobilization plan, removal and demolition approach, installation methodology, testing and commissioning plan, quality assurance, personnel qualifications (include confirmation that calibration/commissioning will be performed by a Hach-certified technician), general schedule, approach to minimizing service interruption for the facility, and optional Hach service plan details.