B01 Attachment J02-a Appendix A.pdf
PDF 6 MB Posted
- Solicitation number
- 75H70125Q00025
About this file
The files are associated with a Design-Build solicitation for McLaughlin Health Center Improvements, specifically an exterior signage and site improvement project. Appendix A depicts an aerial site plan with detailed renovation instructions, including demolishing existing flag pole, sign, and concrete slab, replacing grass, and filling gaps underneath stairs with concrete. The sign design specification shows a 7'6" x 3'6" digital sign for the Standing Rock Service Unit McLaughlin IHS Health Center, featuring a yellow/orange message board reading "Your friendly neighborhood health clinic" with dimensions and technical installation requirements for a Daktronics GT6x RGB display. The project is a 100% Indian Small Business Economic Enterprise (ISBEE) set-aside with a construction budget between $100,000-$250,000, duration of 365 calendar days, and will replace deteriorating exterior elements to modernize the health center's appearance and functionality.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100 ft N
N Image © 2025 Airbus
Image © 2025 Airbus
Image © 2025 Airbus aschwan Rectangle Sketch to Scale 115 sf aschwan Rectangle Sketch to Scale 155 sf aschwan Callout Demo existing concrete slab and replace with new landscaping (TBD during Design) aschwan Callout Demo existing sign and replace with new (see Appendix for new specifications) aschwan Ellipse Sketch to Scale 3 sf aschwan Callout Demo existing flag pole and fill in hole to grade aschwan Rectangle Sketch to Scale 591 sf aschwan Rectangle Sketch to Scale 730 sf aschwan Callout Replace existing grass with new (TBD during Design) aschwan Rectangle Sketch to Scale 9 sf aschwan Text Box Appendix A - McLaughlin Aerial_Exterior Work aschwan Callout Fill in gap underneath stairs to grade with concrete aschwan Rectangle Sketch to Scale 66 sf
7" [178] 8-1/8" [207]
11-1/8" [283]
4" [102]
7' 5-3/8" [2271]
OVERALL WIDTH
7' 2-3/8" [2194]
ACTIVE WIDTH
3' 7-3/16" [1097]
ACTIVE HEIGHT
4' 1-1/4" [1252]
OVERALL HEIGHT
1- 3/
4" 44[
0" 0[
2'
-5 /1
6"
4'
1- 1/
8"
7'
-5 /8
2'
-5 /1
6"
0" 0[
4'
1- 1/
8"
# DETAIL DESCRIPTION
1 DISPLAY GT6x-AAAxBBB-CC (SEE CHART IN TOP LEFT)
2 LED COLOR RGB
3 ACTIVE AREA 3' 7-3/16" [1097] X 7' 2-3/8" [2194]
4 OVERALL SIZE 4' 1-1/4" [1252] X 7' 5-3/8" [2271]
5 CABINET ALUMINUM & STEEL
6 VENTILATION FRONT
7 ACCESS SERVICE FROM FRONT OF DISPLAY
8 WEIGHT 271 LBS 123 KG (APPROX)
9 SHIPPING SHIPPED AS A SINGLE UNIT
10 DIMENSIONS FEET AND INCHES [MILLIMETERS]
11 PAINTED SEMI-GLOSS BLACK
STRUCTURAL RATING
1 DESIGN WIND PRESSURE "P" (CASE A) P<=:100 PSF (ASD)
2 STANDARD/CODE SEE DD4145274 FOR APPLICABLE DESIGN CODE
3 ALL CLIP ANGLES MUST BE USED TO MOUNT DISPLAY
POWER RATING PER SINGLE FACE: FOR SIZING ELEC.SERVICE MAX REQ'D SHOWN
TECHNOLOGY COLOR MAX
WATTS
120 VAC
1 PH
50/60 HZ
AMPS
120/240 VAC1PH
50/60Hz (3 WIRES+GND)
240VAC 1PH 50Hz
(2 WIRES + GND)
INTERNATIONAL
SPECIAL ORDER
LINE 1
(AMPS)
LINE 2
(AMPS)
LINE 1
(AMPS)
GT6x RGB 1891 15.76 N/A N/A 7.88
VENTILATION REQUIREMENTS
DISPLAY RELIES ON VENTILATION TO FUNCTION PROPERLY. INTAKES,
LOCATED AT THE FRONT OF THE DISPLAY, MUST BE ABLE TO DRAW IN
AIR AT A TEMPERATURE NO GREATER THAN 120 F.
IN ORDER TO ENSURE AMBIENT TEMPERATURE AIRFLOW IS MAINTAINED,
NO PORTION OF THE VENTILATION OPENINGS ALONG THE FRONT
OF THE DISPLAY MAY BE COVERED OR OBSTRUCTED IN ANY WAY.
INSTALL NOTES
IN ORDER TO PRESERVE THE STRUCTURAL INTEGRITY OF THE DISPLAY
CABINET, THE 90 ANGLE BETWEEN THE CABINET AND THE LIFTEYE MUST
BE MAINTAINED - USING A SPREADER BEAM IS SUGGESTED. ALL EYEBOLTS
MUST BE USED WHEN LIFTING.
2 1/2" LIFTEYES TO ASSIST WITH DISPLAY INSTALLATION. LIFTEYES MAY NOT
BE USED FOR PERMANENT INSTALLATION. LIFTEYES MAY BE REMOVED.
3 MECHANICAL AND SIGNAL CONNECTIONS OCCUR EXTERNAL TO DISPLAY.
CLIP ANGLE FOR MOUNTING. CLIP ANGLES CAN BE ADJUSTED VERTICALLY
DURING INSTALLATION. CLIP ANGLE CAN BE WELDED OR
BOLTED TO STRINGER. ALL CLIP ANGLE LOCATIONS MUST BE USED.
5 DAKTRONICS IS NOT RESPONSIBLE FOR THE MOUNTING HARDWARE OR
THE INTEGRITY OF THE MOUNTING STRUCTURE.
6 DAKTRONICS IS NOT RESPONSIBLE FOR THE MAIN ELECTRICAL
DISCONNECT. SEE POWER RATINGS ABOVE.
7 SEE DWG-03864398 FOR SIGNAL & MTG DETAILS
PIXELS HIGH (AAA) PIXELS WIDE( BBB) PIXEL SPACING (CC)
180 360 6mm 135 270 8mm 108 216 10mm
REV: DATE: DESCRIPTION: BY:
01 11 MAY 21 PER CN-119371: UNDER STRUCTURAL RATING-STANDARD/CODE.
NOTED TO REFERENCE DD4145274
CJC
20633
THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING
ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY
ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF
DAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.
COPYRIGHT 2019 DAKTRONICS, INC. (USA)
THIRD ANGLE PROJECTION
PROJECT: GT6x DISPLAYS TITLE: SHOP DWG, GT6x, 4' 2''x7' 6'' (3x6 MODS)
DATE: 21-APR-21 DIM UNITS: INCHES [MILLIMETERS] SHEET REV
SCALE: 1/15 DO NOT SCALE DRAWING 1 OF 1 01
DESIGN: TWHITEH JOB NO. FUNC - TYPE - SIZE 4293512DRAWN: TWHITEH P2056 E - 07 - B
DAKTRONICS
SEE INSTALL NOTES #1, #2
EXHAUST AREA
DO NOT COVER
INTAKE AREA
DO NOT COVER
SEE VENT NOTE #2
LIGHT SENSOR
(DO NOT BLOCK)
FRONT VIEW
SEE INSTALL NOTE #7
RIGHT VIEW
SEE STRUCTURAL NOTE #3
AND INSTALL NOTE #4
TOP VIEW
| McLaughlin Aerial_1.pdf |
| Appendix A.pdf |
| IHS.pdf |
| IHS 1.pdf |
| GT6x-180x360-6 shop drawing.pdf |
File details come from the government source that posted it. Updated .