B.8 Pearl Harbor HI ANG PDF Files 09-16-14.pdf

PDF 4 MB Posted

Attached to
Indoor Firing Range Targeting Retrieval System
Solicitation number
W50SLF26QA022
Issued by

About this file

This document is a set of architectural and construction drawings for a 12-lane, 25-meter modular containerized small arms training set (MCSATS) rifle range to be constructed at Joint Base Pearl Harbor-Hickam, Hawaii for the 154th Wing, Hawaii Air National Guard. The project number is 14-187 and the drawings were prepared for construction on September 4, 2014.

The range is designed to accommodate rifle traps rated Model# C-R-3600, with a maximum capacity of 3600 feet per second (FPS) and/or 3800 foot-pounds (FT/LB) of energy. The specifications explicitly prohibit .50 caliber BMG, steel core, and armor-piercing ammunition. The modular design contains 18 shooting lanes arranged in six modules (F1-F3 representing three columns, with A1-E1, A2-E2, and A3-E3 representing rows), with no removable plate sections or future expansion openings. Construction drawings include design layout plans, end elevation views, electrical layout with grounding details, HVAC systems incorporating heat pump units, load calculations and footing details, and utilities layout. The HVAC system requires supply and exhaust air to operate simultaneously with negative air pressure or minimum 10% of total air supply. The range owner/operator is responsible for all maintenance, lead collection and disposal, employee protection, and range safety in accordance with the provided training and maintenance manual, as Shooting Range Industries, LLC disclaims liability for operational maintenance and safety compliance.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO. SHEET TITLE

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE RATED FOR A

MAXIMUM OF 3600 FPS AND/OR 3800 FT/LB. FAILURE TO

MONITOR AMMO BEING USED COULD RESULT IN METAL

PITTING AND EVEN TRAP FAILURE. NO .50 CAL. BMG,

STEEL CORE OR ARMOR PIERCING ROUNDS.

ORTHOGRAPHIC PROJECTION

MAINTENANCE AND RESPONSIBILITIES

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C

A D

S t a t i o n

P l o t

D a t e

P

M F i l e

P a h

C

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

X

J

B a s a r l

H a r b o r

H

A N

G S h e e t s A

C o v e r

S h e e t P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

RIFLE RATED RANGE

COVER SHEET

A0

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

A0 COVER SHEET

A1 M.C.S.A.T.S. DESIGN LAYOUT

A2 END ELEVATION VIEWS

E1 ELECTRICAL LAYOUT

M1 H.V.A.C. LAYOUT

L1 LOAD CALCS/ FOOTING DETAIL

U1 UTILITIES

D1 DETAILS

ORTHOGRAPHIC PROJECTION

MAINTENANCE AND RESPONSIBILITIES

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s A

D e s i g n

L a y o u t P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

M.C.S.A.T.S.

DESIGN LAYOUT

A1

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE

RATED FOR A MAXIMUM OF 3600 FPS

AND/OR 3800 FT/LB. FAILURE TO MONITOR

AMMO BEING USED COULD RESULT IN

METAL PITTING AND EVEN TRAP FAILURE.

NO .50 CAL. BMG, STEEL CORE OR

ARMOR PIERCING ROUNDS.

NOTE: THIS M.C.S.A.T.S. RANGE HAS NO

REMOVABLE PLATE / WALL SECTIONS

OR FUTURE EXPANSION OPENINGS.

KEY PLAN

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3F1

SCALE: 3/16" = 1'-0"

LONGITUDINAL SECTION - DESIGN LAYOUT

PLAN VIEW - DESIGN LAYOUT

SCALE: 3/16" = 1'-0"

NORTH

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s A

E n d

E e v a t i o n s P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

SCALE: 3/8" = 1'-0"

REAR END ELEVATION VIEW

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

M.C.S.A.T.S.

END ELEVATIONS

A2

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE

RATED FOR A MAXIMUM OF 3600 FPS

AND/OR 3800 FT/LB. FAILURE TO MONITOR

AMMO BEING USED COULD RESULT IN

METAL PITTING AND EVEN TRAP FAILURE.

NO .50 CAL. BMG, STEEL CORE OR

ARMOR PIERCING ROUNDS.

E3D3C3B3A3

F2E2D2C2B2A2

E1D1C1B1A1

F3 F1

KEY PLAN

SCALE: 3/8" = 1'-0"

FRONT END ELEVATION VIEW

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3 F1

KEY PLAN

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s E

E l e c t r i c a l

L a y o u t P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

ELECTRICAL LAYOUT

E1

COMBINATION EMERGENCY LIGHT

AND EXIT FIXTURE

120 - 277 2

3.3 FIXTURE WATTS,

LED EXIT, KRYPTON

LAMP HEAD

CEILINGLITHONIA LHQM S W 3

R 120/277

HALOGEN DIMMABLE HALOGEN ACCENT LIGHTS

RB232M WWGR

LIGHTING FIXTURE SCHEDULE

SYMBOL MODEL NO. REMARKSQTY.

120 VOLT

120 VOLT

VOLTAGE REQUIRED LAMPS

NUM. TYPE MOUNTING

CEILING1

20 WATTS

HALOGEN LAMP

32 WATTS, F32T8

FLUORESCENT CEILING DECORATIVE FLUORESCENT FIXTURE

BRAND

LITHONIA

LITHONIA LB 4 32 MVOLT

1/4 GEB10IS

120 - 277 4

32 WATTS, F32T8

FLUORESCENT CEILING DECORATIVE FLUORESCENT FIXTURE

PORTFOLIO 42 INCH, SPOT TRACK FIXTURE KIT,233045 CEILING4

75 WATTS MAX,

OR 3 PAR30/ R30120 VOLT

Lighting protection system to be designed per (NFPA 780) requirements and be provided and installed by others. A (#4/0 CU) counterpoise conductor shall be installed per military design requirements and provided and installed by others. The range shall be grounded per NEC 250.50 requirements. This requirement shall be met by the installation of a concrete-encased electrode (20 ft. bare #4 AWG CU conductor at bottom of footing) or 8' x 5/8" diameter copper ground rod. The lighting protection system shall be bonded to the grounding system per NEC 250.106 requirements. A 4/0 CU conductor shall bond range panel ground bus to counterpoise conductor connected to lightning protection system. The grounding requirements and lightning protection bonding shall be provided and installed by others.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

N

SYMBOL DESCRIPTION

D

S

KEY PLAN

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3F1

NOTE: THIS M.C.S.A.T.S. RANGE HAS NO

REMOVABLE PLATE / WALL SECTIONS

OR FUTURE EXPANSION OPENINGS.

LONGITUDINAL SECTION - DESIGN LAYOUT

PLAN VIEW - ELECTRICAL DESIGN LAYOUT

SCALE: 3/16" = 1'-0"

NORTH

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE

RATED FOR A MAXIMUM OF 3600 FPS

AND/OR 3800 FT/LB. FAILURE TO MONITOR

AMMO BEING USED COULD RESULT IN

METAL PITTING AND EVEN TRAP FAILURE.

NO .50 CAL. BMG, STEEL CORE OR

ARMOR PIERCING ROUNDS.

SCALE: 3/16" = 1'-0"

GROUNDING DETAIL

SCALE: N.T.S.

DETAIL CONNECTION AT OPENING (END WALL)

SCALE: N.T.S.

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s M

H

V A

C

L a y o u t P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

SCALE: 3/16" = 1'-0"

ELEVATION VIEW - H.V.A.C. LAYOUT

PLAN VIEW - H.V.A.C. LAYOUT

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

SCALE: 3/16" = 1'-0"

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

NORTH

M.C.S.A.T.S.

H.V.A.C. LAYOUT

M1

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE

RATED FOR A MAXIMUM OF 3600 FPS

AND/OR 3800 FT/LB. FAILURE TO MONITOR

AMMO BEING USED COULD RESULT IN

METAL PITTING AND EVEN TRAP FAILURE.

NO .50 CAL. BMG, STEEL CORE OR

ARMOR PIERCING ROUNDS.

KEY PLAN

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3F1

6- DWYER MAGNAHELIC PRESSURE GAUGE MODEL NO.

3000-00N C/2000-00N C MAX RANGE PRESSURE 15 PSIG

FOCUS-PRO 8000 DIGITAL/PROGRAMABLE TOUCH SCREEN

THERMOSTAT

EF

1-6

EF = ROOF/BRACKET MOUNTED EXHAUST FAN "DAYTON

5.0 H.P. 230V 1 PH. 12.0 AMP F.L.A. NEMA 3R"

AC

1-6

AC = 10 TON PACKAGED HEAT PUMP A/C UNIT "AMERICAN

STANDARD" HIGH HEAT INPUT 250,000 BTU/OUTPUT 200,000 BTU

208-230V/60Hz/3-PHASE MODEL # WSC120E3EHA0000

AC

AC = HIGH-HEAT HEAT PUMP A/C UNIT "AMERICAN STANDARD"

48,000 BTU 2 TON GAS FIRED HEATING 208-230V/60Hz/3Ø

MODEL# 4WCC3024A1064A

FR

1-6

MODEL # HAL-4-24 FILTER RACK WITH 4- 24"x 24"x 12" 99.97% HIGH VOLUME HEPA FILTERS WITH 4-24"x 24"x 2" PLEATED

PRE-FILTERS

PS1

1-6

TH

1-7

6- DWYER MAGNAHELIC PRESSURE GAUGE MODEL NO.

3000-00N C/2000-00N C MAX FILTER PRESSURE 15 PSIG

PS2

1-6

BALDOR VARIABLE FREQUENCY DRIVE, 3 PHASE, 5 HP.VF

1-6

1) MODULES H.V.A.C. UNITS OFFSET APART.

2) POWER OVERHEAD OR UNDERGROUND T.B.D. BY CUSTOMER.

3) CUSTOMER IS RESPONSIBLE FOR DRAINAGE LOCATION AND

PROTECTION OF CONDENSATE LINES FROM FREEZING.

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s L

L o a d

C a l c s F t g s P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

LOAD CALCULATIONS

AND FOOTINGS DETAILS

L1

Lighting protection system to be designed per (NFPA 780) requirements and be provided and installed by others. A (#4/0 CU) counterpoise conductor shall be installed per military design requirements and provided and installed by others. The range shall be grounded per NEC 250.50 requirements. This requirement shall be met by the installation of a concrete-encased electrode (20 ft. bare #4 AWG CU conductor at bottom of footing) or 8' x 5/8" diameter copper ground rod. The lighting protection system shall be bonded to the grounding system per NEC 250.106 requirements. A 4/0 CU conductor shall bond range panel ground bus to counterpoise conductor connected to lightning protection system. The grounding requirements and lightning protection bonding shall be provided and installed by others.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

1) CLIENT TO DETERMINE FOUNDATION : LENGTH, DEPTH,

AND WIDTH DIMENSIONS BASED ON LOCAL SOIL

CONDITION ANALYSIS.

2) WEIGHTS ARE BASED ON UNFACTORED LOADS.

3) TROWEL FINISH TO TOP OF FOOTING

4) TOLERANCE: HEIGHT = +(1/4") - (1/4")

LENGTH = +(1/2") - (1/2")

5) FINISH GRADE MINIMUM 1" BELOW TOP OF FOOTING

13,500 LBS. (BASED ON UNFACTORED LOAD)13.5

5,600 LBS. (BASED ON 70 LBS/ SQ. FT.)5.6

FOOTING DESIGN MAY CHANGE BASE ON

CUSTOMER REQUIREMENTS AND LOCAL SOIL

CONDITIONS.

12,000 LBS. (BASED ON UNFACTORED LOAD)12

15,500 LBS. (BASED ON UNFACTORED LOAD)15.5

CLIENT SHALL DESIGN THE CONCRETE FOOTINGS

AND ANCHORING SYSTEM PER ASCE 7 OR PER

GOVERNING BUILDING CODE.

KEY PLAN

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3F1

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

PLAN VIEW - BASE PLATE LAYOUT

SCALE: 3/16" = 1'-0"

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s U

U t i l i t i e s P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

UTILITIES LAYOUT

U1

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

ATTENTION:

THIS CURRENT SET OF PLANS

SUPERCEDES ANY PREVIOUS SET OF

PLANS. IT IS THE OWNER'S RESPONSIBILITY

TO FIELD VERIFY ALL BUILDING

DIMENSIONS AND CONSTRUCTION.

RIFLE TRAPS:

MODEL# C-R-3600 RIFLE TRAPS ARE

RATED FOR A MAXIMUM OF 3600 FPS

AND/OR 3800 FT/LB. FAILURE TO MONITOR

AMMO BEING USED COULD RESULT IN

METAL PITTING AND EVEN TRAP FAILURE.

NO .50 CAL. BMG, STEEL CORE OR

ARMOR PIERCING ROUNDS.

KEY PLAN

E3 D3 C3 B3 A3

F2 E2 D2 C2 B2 A2

E1 D1 C1 B1 A1

F3F1

PLAN VIEW - UTILITIES LAYOUT

SCALE: 3/16" = 1'-0"

MAINTENANCE AND RESPONSIBILITIES

NOTICE TO ALL SHOOTING OWNERS, MANAGERS & OPERATORS:

Shooting Range Industries, LLC (SRI) is no way shape or form, responsible for the maintenance, operation, cleanliness, employee protection, lead collection or recycling, disposal or cleanup of any structure provided by SRI, or anyone affiliated or partnered with

SRI.

SRI, or anyone affiliated or partnered with SRI, will not be held liable for any negligence on the part of the structure personnel for any of the above items.

Improper maintenance or repair of the structures(s) by any personnel or it's users for any of the aforementioned items. structure maintenance manuals have been provided with every range manufactured by SRI at time of purchase.

1. H.V.A.C. systems must be in proper working condition and in operation at time of range operation and clean up. SRI is not responsible for this operation (interlocking system).

2. Supply & exhaust air must "always" be on and operating at the same time (interlocked together).

3. Structures must have a negative air pressure or a min. of 10% of total air supply.

4. SRI is not liable for H.V.A.C. system maintenance, air quality, filtration maintenance and air filter change outs.

5. No storage or work to be performed behind bullet traps at any time.

6. SRI suggests lead handling & employee protection by the manual provided by the

National Shooting Sports Foundation (NSSF).

The purpose of this letter/notes is to make sure you, as structure owner, manager, operator, or maintenance personnel are doing your/their part to make sure all people who come in contact with your structure are safe and comfortable in the indoor structure environment.

It is imperative that anyone involved in the operation, maintenance or repair of the structure(s) be diligent at minding all of the safety and operational standards that are set forth to ensure the safety of every shooter and employee that enters your place of business.

GENERAL NOTES

1. Air system comes as a completely balanced system by factory certified H.V.A.C.

specialists however, it is the customers responsibility to maintain a balanced air system.

2. If structure owner/ operator does not understand any of the above operations, lead management, structure safety or will not accept responsibility they should immediately cease all operations to prevent employees and/or customers against health problems or bodily harm.

3. SRI has incorporated the customer's specified wall and ceiling ballistic protection in the building design as has been called out in the customer's design requirements. as such, the customer takes full responsibility to ensure that no ammunition is fired in the range that could exceed the design capabilities the customer has specified in the design requirements. The customer is solely responsible for proper range operation, range maintenance, and range safety in accordance with the range training and maintenance manual.

Rev.

NOTES

C

NOTE:

Drawings must not be scaled. where no dimensions are given, the matter shall be referred to the engineer.

Should dimensions or details on these drawings conflict, precedence shall be given to the larger scale drawing.

Where this drawing relates to existing or completed construction the contractor shall check that there is no conflict between actual building dimensions and drawing dimensions.

Written dimensions on these drawings shall have precedence over scaled dimensions.

contractor to verify and be responsible for all dimensions and conditions in the field. This office must be notified of any variations from the dimensions and conditions shown by these drawings. shop details of adequate scale must be submitted to this office for approval before proceeding with fabrication on items so noted.

Such conflicts noted above shall be reported immediately to the engineer.

The information disclosed in this document contains proprietary data of Shooting Range Industries, LLC. All rights reserved. no part of this document/drawing may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopy, recording or otherwise without the written consent of the intellectual copyright owner, application for which can be made to Shooting Range Industries, LLC. 3885 Rockbottom St., N. Las Vegas, NV 89030. Patent pending.

12-Lane 25 Meters MCSATS

154th WING

(ENCLOSURE 6)

VP MH 06.04.14JC 06.04.14

SRI14187 AS NOTED

14-187 Pearl Harbor Hawaii ANG 1

VSPFOR CONSTRUCTION 09-04-141

REVISION DATE BYDESCRIPTION

L o g i n

C a t i o n

P l o t

D a t e

P

M F i

S

R I

C a d d

D r a w i n g s

R e a d y

R a n g e s

X

B a a r l

H a r b o r

H

A N

G S h e e t s D

D e t a i l s P e a r l

H a r b o r

H

A N

G d w g

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

1 2 3 4 5 6 7 8 9 10 11 1312 14 15 16 17 18

Drawing No.

Project No.

Drawn Date

Scale

Checked Date

Drawing Title

Approved Date

Sheet No.

Sheet of

Project Title

CUSTOMER SIGN OFF:

DATE:

SIGNATURE:

DETAILS

D1

File details come from the government source that posted it. Updated .