Attch 4 - CATM Photos.pdf
PDF 3 MB Posted
- Attached to
- CATM Maintenance and Repair Federal contract opportunity
- Solicitation number
- FA485521Q0001
About this file
This document contains photos and details related to a bullet trap maintenance and repair opportunity with the Department of the Air Force Special Operations Command. The solicitation seeks maintenance and repair services for a bullet trap system and firing point area located at an air force facility. Services include upkeep of horizontal and vertical augers, deceleration chambers, a dust collection unit with 20 HEPA filters, and control room equipment such as an air compressor. The firing point encompasses a 14,904 square foot concrete floor and 1,656 square feet of side walls. The opportunity is a combined synopsis/solicitation for commercial items with no written solicitation to be issued. Quotes are being requested directly by this announcement for the bullet trap maintenance and repair work.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1- Instruction to Offerors_Basis of Award_Eval Crit v1 dated 3 Dec 2020.pdf | ||
| CATM Services QandAs.pdf | ||
| FA485521Q0001 SAPR Cover Letter v1 dated 3 Dec 2020.pdf | ||
| Attch 5 - Provisions and Clauses_CATM services.pdf | ||
| SAPR Cover Letter.pdf | ||
| Attch 1 - Instruction to Offerors_Basis of Award_Eval Criteria.pdf | ||
| Attch 2 - Performance Work Statement.pdf | ||
| PWS Appendix C--CAFB-MAFR Contractor Guide_2018.pdf | ||
| Attch 3 - Wage Determination_6 June 2020_Revision 14_15-5458.pdf | ||
| PWS Appendix D--Hazardous Materials Forms.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Behind Bullet Trap system:
- Both pictures – horizontal augers, deceleration chambers and part of the Dust Collection Unit (DCU) ductwork.
- Top picture – shows part of the Control Room.
- Bottom picture – shows the DCU.
- Top picture – left vertical auger and collection barrel.
- Bottom picture – right vertical auger and collection barrel.
Inside Firing Point Area:
- Both pictures – bullet Trap impact plates and trough.
Inside Firing Point Area:
- Both pictures – bullet Trap impact plates.
- Top/left picture – dust Collection Unit (DCU) with 20 replaceable HEPA filters (double stacked).
- Top/right picture – DCU and ductwork.
- Bottom pictures – DCU control panel with inside view. Current HEPA filter reading is 1.1.
Firing Point Area:
- Top picture – 92’ x 162’ concrete floor (14,904
SF).
- Bottom picture – two 92’ x 9’ side walls (828 SF, total 1,656 SF).
Firing Point Area and Range Safety Officer Booth:
- Top/left picture – Firing point area 92’ x 162’ concrete floor
(14,904 SF).
- Top/right picture – Firing point area and outside Range Safety Officer Booth.
- Bottom/left picture – inside Range Safety Officer Booth:
- 14’ x 9’ tile floor (126 SF)
- 375 SF walls
Control Room behind Bullet Trap system:
- Top picture – Quincy QT-5 air compressor with storage tank.
- Bottom picture – manual Bullet trap system control panel.