Attch 2 Final Submittal Drawings Amended 04 Mar 2022.pdf
PDF 8 MB Posted
- Solicitation number
- FA441722R0001
About this file
This solicitation is for interior and exterior alterations to Building 90322 at Hurlburt Field. The scope of work includes modifying an existing dormitory area on the first floor west wing to accommodate a new office space. Work will include removing existing dormitory partitions and accessories to install new office-type spaces, as well as new interior partitions, lighting, HVAC, and electrical work. The project also requires designing and constructing an antenna support tower. The Department of the Air Force Special Operations Command is the contracting agency.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
91065
90527
9915799156
31022
31022
90639
91006
91158
9113191129
90395 90080
90050
91362
99147
90535
90523
90209
90108
90580
90581
91404
99326
90727
90800
90536
90534
91157
91107
91168
90306
99958
91059
91058
90086
90311
90508
90500
90611
90730
30041
90083
90356
90364
99103
90524
99121
90626
90749
90757
90813
91041
91263
91264
90351
90363
90512 90513
90513
90512
29077
29077
91043
91038
90005
90734
90581
90534
29073
29073
90396 90396
29075
29075
29075
29075
91124
91149
93605
90379
90380
90507
91101
90506
92547
90628
99154
99077
90021
90503
91537
92557
90414
90209
92540
90038
90427
90412
90502
99009
93576
90710
91141
93318
99005
91625
90221
90433
90228
99049
90612
90065
90365
90349
92536
93357
90425
92509
90059
90067
91262
91259
92500
93405
90408
92031
92078
92075
90020
90028
90421
90206
90630
91113
91258
93701
90332
91042
91136
90060
92077
90010
91126
90708
90812
91302
92564
93621
90113
93333
93332
90700
90758
92531
93346
90428
92276
92108
90002
92552
91153
92542
91041
90353
90640
90501
93530
92049
93565
90718
92066
92507
90322
91250
90603
90231
90829
91049
90135
92096
91013
93454
90712
92101
90420
99065
93626
90519
92073
92003 92002
92020
90029
91257
92018
90055
93464
90323
90407
90367
90050
90551
92086
90220
90310
90755
90034
91144
90816
99141
92525
91021
90423 91028
90057
90061
90066
90638
90553
91260
93437
90625
92517
90624
91036
92508
93413
91268
92074
92106
92104 92041
92053
92056
92070
92524
92535
92506 92543
92097
92067
90404
90720
90632
92045
90203
91114
91119
91538
93640
90431
90838
91033
91000
90079
90331
92511
90517
90705
92092
90117
92530
91147
90343
90373
93549
93301
92545
93461
92523
91515
91027
92518
91361
99031
92521
90140
90402
93476
92544
93429
92063
92088
91370
90518
90036
90417
91020
92062
99126
91351
90535
99019
92562
99158
91365
91603
91025
93432
91601
91120
90505
91035
93421
90074
90073
90039
93637
93389
92539
92036
92012
90213
92044
91500
99117
91266
93566
91310
91135
91106
90329
92503
90109
90763
90418
90714
93541
99010
90361
92047
90810
90627
90823
92514
93325
92555
92083
90742
93349
91164
91052
90368
92095
99137
92533
92038
93398
90833
90081
91325
91360
91007
90743
90811
91156
92079
92015
91099
92527
90601
93510
93309
90355
92054
90070
90111
90357
90023
90102
93304
93317
93354
91145
90076
92556
91152
91030
91132
91034
92033
92502
99146
99018
99094
90729
91057
99053
92103
90387
90381
91161
92515
92025
91162
90052
92529
93501
92014
90134
90613
92537
93493
93629
90362
99004
90141
93517
90037
92064
90392
90629
93397
90069
90068
99041
91510
99057
90388
91112
90523
91133
92094
90409
90430
90711
92048
93368
93485
90577
90075
90340
99016
99014
99020
99048
99090
99104
90607
92541
92516
99150
99535
92501
90330
91154
92089
90747
90509
90522
93538
92505
99058
92023
91032
92034
99067
91546
90210
92005
99024
99025
99051
99127
99719
99718 99717
99716
99023
90609
90085
92009
90511
93445
93608
91122
90724
92051
92008
92001
92549
90626
93453
90327
93645
92548
90701
92553
93365
91330
90809
90432
91105
93596
90580
93650
93444
91103
93586
91104
90413
92087
92522
90207
99115
92100
92004
90827
93500
90320
93556
90333
91053
90058
92058
92068
92071
92076
92072
92010
92055 90056
93486
93373
90817
90230
91146
93522
92026 92027
92040
90436
90377
90054
90642
90223
90001
93581
91012
92022
90378
93573
90606
91155
91054
90145
90717
92030 92032
90372
90731
90328
92069
92024
90084
90005
93509
92528
90703
92000
92013
91252
91055
99043
90802
91037
92011
91140
91023
91151
90759
92275
90610
90801
91031
90121
92039
90015
91009
91039
90635
99068
90616
90105
93477
90615
92035
92052
90707
90229
93613
90375
90760
90049
92082 92061
92538
90337
91130
91363
90410
91350
91050
90334
92050
92090
93381 93341
99162
99001
90131
99060
90552
91016
99105 99007
99083
99055
99056
90390
99044
99126
99145
99022
90825
90358
92098
90347
91163
92102
90008
91300
90339
92105
90621
99059
92099
99116
90048
92084
92546
90374
90300
91142
92107
92016 92017
90419
92551
92037
9204392042
92057
92513
91137
92059
90617
93653
92080
90215
90382
90232
93386
90302
93414
99142
90510
92091
90521
93557
91520
91255
90702
90033
93597
92065
93422
90369
90532
90619
90035
90208
90618
90128
90822
90748
90137
93469
90371
93618
9102990352
92060
90138
90063
90806
90525
91047
92021 92019
92028
90326
90438
93589
90713
90064
90370
90115
92519
90426
90062
90636
91045
99030
90531
90051
91254
90304
99500
91056
90366
91364
99042
91303
91148
92093
90880
91301
90815
99118
99029
99061
90225
90416
92046
90439
90053
91265
92085
90030
91400
92550
90716
93542
91159
90359
90032
90106
90637
90325
91307
99045
91048
90761
90101
92081
90600
93660
90434
9200792006
90308
90043
Tully Street
M A
Y S
T R
E E
T
Downs Road
W alkup W ay
M artin
L uther K ing
Downs Road
Kanuha Driv e
Blessi nger D r iv e
Bartley Street
Mitchell Road
Independence Road
T er ry A v en u e
McC lea n Street
Harts on Stre et
Tully Street
M a in te na nc e H a u l R o a
Howie Walters W ay
Lielmanis Avenue
K e rw o o d
R oa d
C od y Ave nu e
Lukasik Avenue
Tully Street
R ed
H or se R oa d
H am by Place
Westfal l C ircl e
Bedel Street
T u lly S tr e e t
T ully Street
Benn ett A ve nue
C ru z A ve n u e
Red Horse Road
C ru z A ve n u e
Frazier Street
B e n n e tt
A v e n u e
Bedel Street
Independence Road
W alkup W ay
McMillan Street
US98
W e av er
A v e nu e
Schmauss Lane
Clark Road
Gelshlager Street C o d y A v enu e
Independence Road
O 'N e il
A ve n u e
US98
Harrison Drive
Acha Drive
Walters Drive
Hodges Street
Galvan Street
Bland Street
Grimm Lane unk unk
Tully Street
Red H orse
Road
Bakke Street
M a yo S tre et
Bakke Street
Tupelo Circle
Red Horse Road
S im p son A venu e
Tully Street
F ox x A ve n ue
Le to ur n e a u
C irc le
L e to u rn e a u
C irc le
NORTH
BASE MAP
MARTIN LUTHER KING JR. BLVD
INTERSECTION ENTRANCE
COMMERCIAL VEHICLE INSPECTION
ENTRANCE PASS & ID OFFICE
HURLBURT EAST GATE, NO
COMMERCIAL ENTRANCE
FIRE DEPARTMENT BLDG 90734
CONTRACTOR HAUL ROUTE
HURLBURT FIELD, FLORIDA
CP1028223
NORTH
PROJECT SITE
NORTH
PLAN
BLDG. 90322
ALTER INTERIOR & EXTERIOR BUILDING 90322
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
G-001
5/26/20
T
IT
LE
S
H E
E T
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
1070200712C Typewritten Text
1070200712C Typewritten Text 3/4/2022
1070200712C Typewritten Text Amended
ABBREVIATIONS
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
R RADIUS, RANGE, RISER
RCP REFLECTED CEILING PLAN
RD REINFORCING STEEL BARS REBAR
REF REFERENCE, REFRIGERATOR
REG REGISTER
REINF REINFORCE
RET RETURN
REV REVISION
RH RIGHT HAND
RM ROOM
ROW RIGHT OF WAY
SC SOLID CORE
SCHED SCHEDULE
SD STORM DRAIN
SECT SECTION
SF SQUARE FOOT(FEET)
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
SS SERVICE SINK
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPEND
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TE TOP ELEVATION
TEL TELEPHONE
TOC TOP OF CONCRETE
TOS TOP OF SLAB, TOP OF STEEL
TV TELEVISION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VCT VINYL COMPOSITION TILE
VTR VENT THROUGH ROOF
W WASHER, WEST, WIDE
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WP WATERPROOFING
WSCT WAINSCOT
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT, ADJOINING, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ARCH ARCHITECT(URAL)
BD BOARD
BLDG BUILDING
BOT BOTTOM
BRG BEARING
BRG PL BEARING PLATE
BUR BUILT-UP ROOFING
CF/CI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CF/GI CONTRACTOR FURNISHED/
GOVERNMENT INSTALLED
CID COMPREHENSIVE INTERIOR
DESIGN PACKAGE
CIP CAST-IN-PLACE, CAST IRON PIPE
CJ CONSTRUCTION JOINT/CONTROL
JOINT
CL CENTER LINE, CLASS, CLOSE
CLG CEILING
CLR CLEAR, COLOR, COOLER
CMU CONCRETE MASONRY UNIT
CPT CARPET
COL COLUMN
CONC CONCRETE
CONT CONTINUE, CONTINUOUS
CONTR CONTRACT, CONTRACTOR
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
COTR CONTRACTING OFFICER
TECHNICAL REPRESENTATIVE
CU FT CUBIC FEET
CU YD CUBIC YARD
D DRYER
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EWS EYE WASH STATION
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXT EXTERIOR
FA FIRE ALARM
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF EL FINISH FLOOR ELEVATION
FIN GR FINISH GRADE
FLR FLOOR
FP FIREPROOF
FT FEET, FOOT
FTG FOOTING
GA GAGE
GALV GALVANIZED IRON
GB GRAB BAR
GC GENERAL CONTRACTOR
GF/GI GOVERNMENT FURNISHED/
GOVERNMENT INSTALLED
GF/CI GOVERNMENT FURNISHED/
CONTRACTOR INSTALLED
GL GLASS
GLZ GLAZING
GMS GALVANIZED METAL STUD
GYP BD GYPSUM BOARD
HB HOSE BIBB
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING/VENTILATING/AIR COND
IBC INTERNATIONAL BUILDING CODE
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MS MOP SINK
MT MOUNT
MTD MOUNTED
MTG MEETING
MTL METAL
MW MICROWAVE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OF/OI OWNER FURNISH/
OWNER INSTALLED
OF/CI OWNER FURNISH/
CONTRACTOR INSTALLED
OH OVERHANG, OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OPNG OPENING
OPP OPPOSITE
PCF POUNDS PER CUBIC FOOT
SYMBOLS LEGEND
ROOM NAME / NUMBER
DESIGNATION
DOOR NUMBER
WINDOW / LOUVER
TYPE
WALL TYPE
ELEVATION
TARGET
ELEVATION NUMBER
INTERIOR ELEVATION
SYMBOL
SHEET ON WHICH
ELEVATION IS DRAWN
ELEVATION NUMBER
EXTERIOR ELEVATION
SYMBOL
SHEET ON WHICH
ELEVATION IS DRAWN
NORTH ARROW
SECTION NUMBER
SECTION SYMBOL
SHEET ON WHICH
SECTION IS DRAWN
DETAIL NUMBER
DETAIL SYMBOL
SHEET ON WHICH
DETAIL IS DRAWN
PLAN
NORTH
A101
SIM
A
A
4 A-200
ROOM NAME
A-201
PLAN NORTH
TRUE NORTH A-201
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
G-002
5/26/20
S H
E E
T
IN
D E
X
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
INDEX OF DRAWINGS
SHEET
NUMBER SHEET NAME
GENERAL
G-001 TITLE SHEET
G-002 SHEET INDEX
G-003 ASBESTOS ABATEMENT PLAN
STRUCTURAL
S-001 STRUCTURAL INFORMATION
ARCHITECTURAL
A-001 LIFE SAFETY PLAN
A-002 WALL TYPES
A-003 TOWER PLACEMENT
A-101 1ST FLOOR DEMO PLAN
A-110 1ST FLOOR PLAN
A-150 1ST FLOOR CEILING DEMOLITION PLAN
A-151 CEILING PLAN
A-310 WALL SECTIONS
A-401 ENLARGED PLANS
A-450 CASEWORK ELEVATIONS AND SECTIONS
A-501 PLAN DETAILS
A-601 DOOR SCHEDULE, ELEVATIONS, AND DETAILS
A-602 DOOR DETAILS
INTERIOR
I-101 FINISH, SIGNAGE AND CORNER GUARD PLAN
I-102 FURNITURE PLAN
I-120 FINISH PLAN, SCHEDULE AND DETAILS
FIRE PROTECTION
FP-101 1ST FLOOR DEMOLITION WORK - FIRE PROTECTION
FP-201 1ST FLOOR NEW WORK - FIRE PROTECTION
FIRE ALARM
FA-101 FIRST FLOOR FIRE ALARM/MASS NOTIFIC. SYSTEM PLAN
PLUMBING
P-100 PLUMBING PLAN - DEMOLITION
P-101 PLUMBING PLAN - WASTE
P-102 PLUMBING PLAN - WATER
P-103 WASTE RISER DIAGRAM
P-104 DETAILS AND LEGEND
P-105 PLUMBING NOTES AND SCHEDULES
MECHANICAL
M-001 GENERAL MECHANICAL INFORMATION
M-101 1ST FLOOR DEMOLITION WORK - AREA A - HVAC
M-102 1ST FLOOR DEMOLITION WORK - AREA B - HVAC
M-201 1ST FLOOR NEW WORK - AREA A - HVAC
M-202 1ST FLOOR NEW WORK - AREA B - HVAC
M-501 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES AND CONTROLS
ELECTRICAL
E-001 LEGEND, RISER DIAGRAM
E-002 LIGHTING FIXTURE DETAILS
E-101 ELECTRICAL DEMOLITION PLAN
E-102 1ST FLOOR LIGHTING PLAN
E-103 1ST FLOOR POWER PLAN
E-104 SECURITY SYSTEM PLAN
TELECOMMUNICATIONS
T-001 1ST FLOOR TELECOMMUNICATIONS PLAN
T-101 1ST FLOOR TELECOMMUNICATIONS PLAN
UP
REF.
A
C
D
B
E
91011121314151617
EXISTINGNEW WORK
A-4505
A-601
ACM ABATEMENT
CONTRACTOR NOTES
1. ERECT BARRICADES AND POST DANGER SIGNS
NECESSARY TO RESTRICT PUBLIC ACCESS TO WORK
AREA.
2. SHUT DOWN POWER AND HVAC SYSTEMS SUPPLYING
WORK AREA. PROVIDED TEMPORARY POWER AND
LIGHTING WITH GFCI PROTECTION.
3. PRE-CLEAN THEN SEAL CRITICAL BARRIERS TO WORK
AREA WITH 6-MIL PLASTIC SHEETING.
4. ERECT WORKER AND EQUIPMENT DECONTAMINATION
UNITS AS SPECIFIED.
5. PRE-CLEAN WORK AREA AND CONSTRUCT
CONTAINMENT SYSTEM AS PRESCRIBED.
6. INSTALL / INITIATE OPERATION OF NEGATIVE
PRESSURE VENTILATION SYSTEMS WITH PRESSURE
DIFFERENTIAL MONITORING DEVICE.
7. UTILIZE SPECIFIED RESPIRATORY PROTECTION AT
ALL TIMES IN WORK AREA.
8. REMOVE ALL ACM INDICATING IN THE DRAWINGS AND
IN THE ABATEMENT SPECIFICATIONS.
9. STORE, TRANSPORT, AND DISPOSE OF BAGGED /
CONTAINERIZED ACM WASTE / DEBRIS AS INDICATED
IN THE SPECIFICATION.
GRAPHIC LEGEND
ASBESTOS CONTAINING FLOOR
TILE AND / OR FLOOR TILE MASTIC
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
G-003
5/26/20
A S
B E
S T
O S
A B
A T
E M
E N
T P
LA
N
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
PLAN
NORTH
1/8" = 1'-0"G-003
1 FIRST FLOOR PLAN ASBESTOS ABATEMENT PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
3.00 REINFORCED CONCRETE
3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301�10, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318�11, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315, DETAILING MANUAL. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.
3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE FOLLOWING MINIMUM
28 DAY COMPRESSIVE STRENGTHS:
A. FOUNDATIONS 3500 PSI
B. SLAB�ON�GRADE 3500 PSI
THE USE OF ALL ADMIXTURES MUST BE APPROVED BY THE CONTRACTING OFFICER. THE USE OF SUPERPLASTICIZERS
IS PROHIBITED UNLESS APPROVED BY THE CONTRACTING OFFICER.
3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.
3.04 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH IS THE CONTRACTOR'S.
3.05 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.
3.06 CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".
3.07 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL
CONSTRUCTION ACTIVITIES. "STICKING” DOWELS INTO WET CONCRETE IS NOT PERMITTED.
3.08 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED;
STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION
SPLICES (CLASS "B") UNLESS NOTED OTHERWISE. TERMINATE BARS WITH STANDARD HOOKS.
3.09 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE (PER ACI
318�05 PAR.7.7.1):
A. CONCRETE AGAINST EARTH (NOT FORMED): 3"
B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:
1. #6 THROUGH #18 BARS: 2"
2. #5 BARS AND SMALLER: 1�1/2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
1. SLABS AND WALLS: 1"
2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1�1/2"
3.10 DO NOT PLACE DUCTS EXCEEDING ONE�THIRD THE SLAB OR WALL THICKNESS WITHIN THE SLAB OR WALL
UNLESS SPECIFICALLY SHOWN AND DETAILED ON STRUCTURAL DRAWINGS.
3.11 DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE CONTRACTING
OFFICER.
3.12 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER, OR BY A
REPRESENTATIVE RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 1.3.1)
4.00 STRUCTURAL STEEL
4.01 STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC "SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS, LATEST EDITION.
4.02 STRUCTURAL STEEL SHOP DRAWINGS SHALL BE PREPARED IN ACCORDANCE WITH AISC MANUAL "DETAILING FOR STEEL CONSTRUCTION", LATEST EDITION. STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. DO NOT BEGIN FABRICATION UNTIL THE SHOP DRAWINGS ARE COMPLETED AND REVIEWED.
4.03 STRUCTURAL STEEL CONNECTIONS SHALL HAVE SIGNED AND SEALED CONNECTION CALCULATIONS PROVIDED
BY A PROFESSIONAL ENGINEER.
4.04 STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL SHAPES, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI, UNLESS NOTED OTHERWISE. STEEL PIPE SHALL CONFORM TO ASTM A501 OR ASTM A53, TYPE E OR S, GRADE B. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GR. 36 UNLESS
NOTED OTHERWISE.
4.05 BOLTS SHALL CONFORM TO ASTM A325, 3/4�INCH DIAMETER MINIMUM, UNLESS NOTED OTHERWISE.
COMPRESSIVE�WASHER�TYPE DIRECT TENSION INDICATORS OR TWIST�OFF�TYPE TENSION�CONTROL BOLTS
CONFORMING TO RCSC SHALL BE PROVIDED AT ALL BOLTED CONNECTIONS PER UFC 3�301�01.
4.06 ALL COLUMNS, UNLESS NOTED OTHERWISE, SHALL BEAR ON GROUT BED. GROUT SHALL BE NON�SHRINK, NON�
METALLIC.
4.07 USE PRE�QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1 "STRUCTURAL WELDING CODE." USE ONLY CERTIFIED WELDERS; ALL ELECTRODES SHALL CONFORM TO AWS A5 GRADE E70XX. BARE ELECTRODE AND GRANULAR FLUX SHALL CONFORM TO AWS A5, F70 AWS FLUX CLASSIFICATION. MINIMUM WELD SIZE TO BE 3/16" FILLET WELD, U.N.O.
4.08 CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL
NOT BE PERMITTED.
4.09 PROVIDE TEMPORARY BRACING OF STRUCTURAL FRAMING TO PROVIDE LATERAL SUPPORT UNTIL ALL PERMANENT BRACING MOMENT CONNECTIONS AND FLOOR AND ROOF DECKS (DIAPHRAGMS) ARE COMPLETELY
INSTALLED.
4.10 UNLESS SPECIFICALLY NOTED AND DETAILED BY THE TOWER DESIGNER, HOLES IN BEAMS ARE NOT PERMITTED.
4.11 ALL STEEL SHALL BE HOT DIP GALVANIZED PRIOR TO INSTALLATION. ALL METAL GRATING SHALL BE GALVANIZED AND BY McNICHOLS GRATING (OR EQUAL).
1.00 GENERAL NOTES
1.01 THESE STRUCTURAL NOTES SHALL BE APPLIED WITH THE TECHNICAL SPECIFICATIONS IN THE SPECIFICATIONS MANUAL. ANY CONFLICTING REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER FOR RESOLUTION BEFORE PROCEEDING WITH FABRICATION OR CONSTRUCTION.
1.02 ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE, 2018.
1.03 THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:
A. UFC 1�200�01, GENERAL BUILDING REQUIREMENTS, 8 OCTOBER 2019
B. UFC 3�301�01, STRUCTURAL ENGINEERING, 1 OCTOBER 2019
C. UFC 3�310�04, SEISMIC DESIGN FOR BUILDINGS, CHANGE 1, 20 JUNE 2016
D. UFC 4�010�01, DOD MINIMUM ANTITERRORISM STANDARD FOR BUILDINGS, CHANGE 1,
12 DECEMBER 2018
E. INTERNATIONAL BUILDING CODE, 2018
F. ASCE 7�16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
G. ACI 318�14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
H. ACI 360 R�10, DESIGN OF SLAB ON GRADES
I. AISC 360�10, SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION
1.04 WIND LOADS � WIND PROVISIONS OF ASCE 7�16 ARE AS FOLLOWS:
A. ULTIMATE BASIC WIND SPEED: 145 MPH
B. BUILDING RISK CATEGORY: II
C. WIND EXPOSURE CATEGORY: C
D. INTERNAL PRESSURE COEFFICIENT: +/�0.00 (OPEN)
1.05 EARTHQUAKE LOADS � DESIGN DATA IS AS FOLLOWS:
A. SEISMIC DESIGN CATEGORY: B
B. SPECTRAL RESPONSE COEFFICIENTS
1. Ss = 0.08g Sds = 0.09g
2. S1 = 0.05g Sd1 = 0.08g
C. SITE CLASSIFICATION: D
D. BASIC SEISMIC�FORCE�RESISTING SYSTEM: STEEL ORDINARY CONCENTRIC BRACED FRAMES
E. SEISMIC RESPONSE COEFFICIENT, (Cs): 0.033
F. RESPONSE MODIFICATION COEFFICENT (R): 3.5
G. SEISMIC BASE SHEAR (V): N/A
H. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
1.06 DESIGN GRAVITY LOADS ARE AS FOLLOWS:
A. SUPERIMPOSED DEAD LOADS:
1. TOWER SELF�WEIGHT
B. LIVE LOADS: (MAY BE REDUCED PER CODE)
1. STAIRS AND EXITS: UNIFORM: 100 PSF
CONCENTRATED: 300 LBS
1.07 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
1.08 CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVAL OF THE CONTRACTING OFFICER. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS. NOTIFY CONTRACTING OFFICER OF ANY CONFLICT
AND/OR OMISSION.
1.09 REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE CONTRACTING OFFICER DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE CONTRACTING OFFICER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION.
2.00 FOUNDATIONS
2.01 THE TOWER FOUNDATION SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER IN ACCORDANCE WITH THE
PROJECT'S GEOTECHNICAL REPORT.
2.02 A QUALIFIED GEOTECHNICAL ENGINEER SHALL CHECK COMPACTION OF THE FOOTINGS. THE TOP TWELVE INCHES OF THE SOILS BENEATH FOOTINGS SHALL BE COMPACTED TO 98% OF THE MODIFIED PROCTOR MAXIMUM
DENSITY.
2.03 A QUALIFIED GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND/OR ADEQUACY OF ALL SUBGRADES, FILLS AND BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS, WALLS, FILLS, BACKFILLS, ETC.
SHOULD THE CONTRACTOR FIND UNDESIRABLE SOILS, HE SHALL STOP WORK AND IMMEDIATELY CONTACT THE CONTRACTING OFFICER. ALL FOOTINGS SHALL REST EITHER ON UNDISTURBED SOIL OR A MANUALLY OPERATED VIBRATORY SLED OR TAMPER SHOULD BE USED TO DENSIFY ANY SOILS IN THE BOTTOM OF THE FOOTING
TRENCHES LOOSENED DURING THE EXCAVATION OPERATION.
2.04 SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. FOUNDATIONS POURED AGAINST THE EARTH REQUIRE THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE
PLACEMENT.
2.05 CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY PROTECTING ALL EXCAVATION SLOPES.
D
EU
SOJ
R E
G
IS TERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
ADIOL
F
R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
AT
IO
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
S-001
03/04/2022
S T
R U
C T
U R
A L
IN
F
O R
M A
T
IO
N
JTG
JTG
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B L D
G
3/4/2022 3/4/2022 3/4/2022 3/4/2022
/0 4/
A M
E N
D M
E N
T
N
O T
E R
E V
IS
IO
N S
LIFE SAFETY DATA - INTERNATIONAL BUILDING CODE 2018 EDITION
NATIONAL FIRE PROTECTION ASSOCIATION LIFE SAFETY CODE 101, 2018 EDITION
OCCUPANCY
IBC
BUSINESS
NFPA 101
BUSINESS
CONSTRUCTION TYPE:
ELEMENT
STRUCTURAL FRAME - COLUMNS TRUSSES, BEAMS AND GIRDERS
REQUIREMENT
0 HOURS
BEARING WALL - EXTERIOR
BEARING WALLS - INTERIOR
FLOOR
ROOF - INCLUDING SUPPORTING FRAMING
STRUCTURAL FRAME - COLUMNS TRUSSES, BEAMS AND GIRDERS
REQUIREMENTS FROM IBC TABLE 602
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
HEIGHT ANALYSIS
OCCUPANCY
B
IBC ALLOWED HEIGHT PROJECT HEIGHT
NOTES
AREA ANALYSIS
OCCUPANCY IBC ALLOWED AREA
92,000 SF
PROJECT AREA
NO CHANGEB
4 STORIES/75 FEET 3 STORIES/NO CHANGE
INTERIOR FIRE RESISTANCE
ELEMENT
ANY SPACE OF GREATER HAZARD
REQUIREMENT
0 HOURS
SOURCE
NFPA 101 8.7.1 - SPRINKLER COVERAGE
OCCUPANT LOAD
AREA
BLDG 90322 RENO
USE
BUSINESS
SQUARE FEET
4188 GSF
LOAD FACTOR
150 GSF
OCCUPANT LOAD
TOTAL
ARRANGEMENT OF MEANS OF EGRESS
MAXIMUM TRAVEL DISTANCE TO EXIT
MAXIMUM DEAD END
300 FEET
50 FEET
MAXIMUM COMMON PATH OF TRAVEL 100 FEET
NFPA 101 - 38.2.6.23
NFPA 101 - 38.2.5.2.1
NFPA 101 - 38.2.5.3.1
NOTE: EXIT CAPACITY PROVIDED = 350 PERSONS FOR AREA OF RENOVATION
CORRIDOR WIDTH 44" NFPA 101 - 38.2.3.2
IBC IIB / NFPA II-000
NOTE: BUILDING IS EXISTING. INTERIOR RENOVATIONS ONLY. NO NEW BUILDING
AREA. PRIMARY EXITING TO REMAIN.
LIFE SAFETY LEGEND
EXIT CAPACITY (OCCUPANTS)
EXIT PATH NUMBER WITH SEGMENT
TRAVEL DISTANCE AND DIRECTION OF
TRAVEL. SEE EXIT DISTANCE CHART FOR
TOTAL EXIT DISTANCES.
1-1
27' -6"
EXIT SIGN (SHADED REGION
INDICATES LIGHTED SIDE)
ROOM NAME / NUMBER DESIGNATION
ROOM NAME
1-HR FIRE RATED WALL ASSEMBLY
EGRESS A
EGRESS B
<170>
<180>
A-1
19'-11"
A-2
45'-9"
A-4
4'-4"
B-1
11'-10"
B-2
13'-0"
B-3
35'-0"
1-HR FIRE RATED WALL AT LOBBY
DOOR ALWAYS AVAILABLE
FOR EXITING - NO DEAD
END CORRIDOR
EXISTINGNEW WORK
A-3
19'-3"
RADIO & EQUP.
LAB
CONF.
OFFICE
BREAK
MECH.
ELEC/ COMM
FRONT OFFICE
STOR.
UNISEX
UNISEX
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-001
5/26/20
LI
F
E S
A F
E T
Y P
LA
N
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B L D
G
PLAN
NORTH
3/32" = 1'-0"A-001
1 FIRST FLOOR PLAN LIFE SAFETY
SCALE: 3/32" = 1'-0"
0 5'-4" 10'-8" 21'-4"
EXIT DISTANCE
EXIT PATH #
TOTAL TRAVEL
DISTANCE
EGRESS A 89' - 2"
EGRESS B 60' - 1"
WALL TYPES
WALL TYPE "1" WALL TYPE "3"
WALL TYPE "4"
WALL TYPE "5" WALL TYPE "6"
WALL TYPE "7"
WALL TYPE "2" - STC 50
WALL TYPE "8"
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-002
5/26/20
W A
LL
T
Y P
E S
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
WALL TYPE SCHEDULE
MARK DESCRIPTION
1 3 5/8" METAL STUDS AT 16" O.C. W/ ONE LAYER 5/8" GYPSUM WALLBOARD ON EACH SIDE WITH ACOUSTICAL INSULATION IN STUD CAVITY TO UNDERSIDE OF FLOOR ABOVE. AT RESTROOMS REPLACE GYPSUM WALLBOARD WITH CEMENTITIOUS BACKER BOARD.
2 3 5/8" METAL STUDS AT 16" O.C. W/ ONE LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON SECURE SIDE, 2 LAYERS 5/8" TYPE "X" GYPSUM WALLBOARD ON UNSECURED SIDE, WITH 1 1/2" ACOUSTICAL INSULATION IN STUD CAVITY TO UNDERSIDE OF FLOOR ABOVE. EXTEND TO DECK ABOVE. SEAL ALL PENETRATIONS THRU WALL AND WALL PERIMETER. SA-800504
3 3 5/8" METAL STUDS AT 16" O.C. TO STRUCTURE ABOVE W/ ONE LAYER 5/8" GYPSUM WALLBOARD ON EACH SIDE TO MIN. 6" ABOVE
ADJACENT CEILING.
4 EXISTING WALL CONSTRUCTION. PROVIDE NEW 1 5/8" METAL STUDS AT 16" O.C. (BRACE AT 3RD POINTS) AND ONE LAYER 5/8" GYPSUM WALLBOARD ON FINISH SIDE. EXTEND TO DECK ABOVE. SEAL ALL PENETRATIONS THRU WALL AND WALL PERIMETER.
HOLD STUDS 1/2" OFF EXISTING WALL CONSTRUCTION TO ALLOW FOR EXISTING VARIATION.
5 EXISTING WALL CONSTRUCTION. PROVIDE NEW 1 5/8" METAL STUDS AT 16" O.C. WITH ACOUSTICAL INSULATION IN STUD CAVITY (BRACE AT 3RD POINTS) AND ONE LAYER 5/8" MOLD-RESISTANT GYPSUM WALLBOARD ON FINISH SIDE. EXTEND TO DECK ABOVE.
SEAL ALL PENETRATIONS THRU WALL AND WALL PERIMETER. HOLD STUDS 1/2" OFF EXISTING WALL CONSTRUCTION TO ALLOW
FOR EXISTING VARIATION.
6 EXISTING WALL CONSTRUCTION (CMU W/ FURRING). PROVIDE ONE LAYER 5/8" GYPSUM WALLBOARD ON FINISHED SIDE TO MIN. 6"
ABOVE ADJACENT CEILING.
7 EXISTING WALL CONSTRUCTION. PROVIDE NEW 1 5/8" METAL STUDS AT 16" O.C. WITH ACOUSTICAL INSULATION IN STUD CAVITY (BRACE AT 3RD POINTS) AND ONE LAYER 5/8" TYPE "X" GYPSUM WALLBOARD ON FINISH SIDE. EXTEND TO DECK ABOVE. SEAL ALL PENETRATIONS THRU WALL AND WALL PERIMETER.HOLD STUDS 1/2" OFF EXISTING WALL CONSTRUCTION TO ALLOW FOR EXISTING
VARIATION.
8 3 5/8" METAL STUDS AT 16" O.C. W/ ONE LAYER 5/8" GYPSUM WALLBOARD ONE SIDE WITH ACOUSTICAL INSULATION IN STUD CAVITY TO UNDERSIDE OF FLOOR ABOVE. AT RESTROOMS REPLACE GYPSUM WALLBOARD WITH CEMENTITIOUS BACKER BOARD.
BLDG. 90322
TOWER LOCATION
GENERAL: CONTRACTOR TO PROVIDE COMPLETE
ANTENNA TOWER PACKAGE INCLUDING DESIGN,
ENGINEERING AND COMPLETE BUILD OUT OF THE
TOWER. THE TOWER DESIGN MUST BE
SIGNED/SEALED BY A LICENSED PROFESSIONAL
ENGINEER. LOADING REQUIREMENTS ARE PER
STRUCTURAL NOTES.
1. CONTRACTOR IS TO DEMOLISH THE GYM
EQUIPMENT THIS SIDE OF THE BUILIDNG.
MODIFY THE PERIMETER CONTAINMENT AREA
OF THE GRAVEL SURFACE AS NEEDED TO
ALLOW FOR THE ANTENNA CONSTRUCTION.
2. CONTRACTOR TO PROVIDE MIN. 66'-6"
PLATFORM HEIGHT GALVANIZED STEEL
ANTENNA TOWER WITH STEEL STAIRS. TOP
PLATFORM SHALL BE MIN. 4' WIDE. TOP
PLATFORM SHALL BE 20'-2" MIN. SQUARE AREA.
THE PLATFORM SHALL HAVE A 3'6" HIGH
GUARDRAIL AT BOTH INTERIOR AND EXTERIOR
PERIMETER. RAILINGS TO BE MIN. 1-1/2"
SCHEDULE 40 GALV. PIPE RAILINGS.
GUARDRAIL SHALL MEET OSHA
REQUIREMENTS. A HIGHER GUARDRAIL MAY
BE NECESSARY. COORDINATE WITH BUILDING
HEIGHT TO ENSURE ADEQUATE LINE OF SIGHT
FOR ANTENNA POSITIONS.
3. TOWER FOUNDATION SHALL BE DESIGNED BY
PROFESSIONAL ENGINEER BASED ON THE
GEOTECHNICAL REPORT PROVIDED IN THE
SPECIFICATIONS. FOUNDATIONS SHALL
CONSIST OF FOUR (4) REINFORCED CONCRETE
PIERS SUPPORTING MAIN STEEL SUPPORTS.
STEEL SUPPORTS WILL BE WELDED TO A
PLATE WHICH WILL BE SET IN 1" GROUT AND
BOLTED INTO PIERS.
4. MAIN STEEL MEMBERS WILL HAVE WELDED
GUSSET PLATES ALLOWING THE REMAINDER
OF THE STEEL TO BE BOLTED TOGETHER FOR
FUTURE DISASSEMBLY IF REQUIRED. THE
STEEL TOWER WILL HAVE CROSS BRACING AT
ALL BAYS AND BOTTOM BAY WILL HAVE
CHEVRON BRACING. BRACING WILL ALLOW
ACCESS TO STAIRS.
5. STAIRS SHALL BE PROVIDED TO THE
PLATFORM AND ROTATED 45 DEGREES FROM
STRUCTURE. STAIRS WILL BE SUPPORTED BY
BEAMS AND CHANNELS. STRINGERS SHALL BE
MIN. 4'-4" OUT TO OUT WITH 8" BETWEEN THE
STRINGERS. STAIR TREADS TO BE SOLID
PLATE. RAILINGS TO BE MIN. 1-1/2" SCHEDULE
40 GALV. PIPE RAILINGS TO OSHA STANDARDS.
6. TOWER SHALL HAVE A CONCRETE PAD
DESIGNED BY PROFESSIONAL ENGINEER AT
GRADE. THE PAD SHALL BE 1'-0" LARGER EACH
DIMENSION THAN THE TOWER PLATFORM. THE
PAD AND TOWER WILL BE ENCLOSED BY A 6'
HIGH CHAIN LINK FENCE WITH A MIN. 5' SWING
GATE. COORDINATE THE EXACT LOCATION
WITH EXISTING MECHANICAL EQUIPMENT TO
REMAIN. ALLOW ACCESS AROUND ALL
EQUIPMENT.
7. COORDINATE THE ANTENNA CONSTRUCTION
WITH THE ELECTRICAL, COMMUNICATIONS AND
LIGHTNING PROTECTION SYSTEMS NOTED ON
ELECTRICAL DRAWINGS.
SCOPE OF WORK
A. THE TOWER TO BE COMPRISED OF
GALVANIZED STEEL AND STAIRS ARE
REQUIRED. THE ANTENNA SUPPORT TOWER
PLATFORM IS FOR FREQUESNT ANTENNA
MAINTENANCE, ETC. THE GUARDRAILS AT THE
PERIMETER OF THE TOWER PLATFORM ARE TO
BE UTILIZED FOR MOUNTING ANTENNAS.
B. DESIGN OF THE TOWER IS BASED ON
ANSI/TIA-222-G AND SIMILAR TO THE TOWER AT
BUILDING 90801. A UL CERTIFIED LIGHTNING
PROTECTION SYSTEM IS REQUIRED AND MUST
UTILITZE THE REQUIREMENTS OF UFGS
SECTION 26.41.00 LIGHTNING PROTECTION
SYSTEM. tHE SYSTEM SHALL BE IN
ACCORDANCE WITH NFPA 780 USING
COMPONENTS MANUFACTURED IN
ACCORDANCE WITH UL 96. THE SYSTEM MUST
BE INSPECTED AND CERTIFIED BY A THIRD
PARTY INSPECTOR AS COMPLIANT WITH AFI
32-1065 AND NFPA 780. THE DESIGN OF THIS
TOWER MUST INCLUDE AN INTERIM SUBMITTAL
FOR REVIEW AND APPROVAL AND A FINAL
SUBMITTAL REVIEW AND APPROVAL BY THE
GOVERNMENT BEFORE ORDERING AND
CONSTRUCTION ON IT BEGINS.
C. INFORMATION OF THE GFGI COMPONENTS ARE
ATTACHED IN SPECIFICATION APPENDIX C.
D. AN EROSION CONTROL PLAN FOR THE TOWER
LOCATION IS TO BE SUBMITTED BY THE
CONTRACTOR.
E. WIND LOADS ARE PER DRAWING S-001, NOTE
1.04, BASIC WIND SPEED 145 MPH.
F. SIZE AND QUANTITIES OF TRANSMISSION
LINES TO BE INSTALLED ON TOWER: LMR-600
(CABLE) X 25 EA. (GFGI)
G. ANTENNAS ARE OMNIDIRECTIONAL AND RH
CIRCULAR POLARIZED. SOME ARE
STEERABLE/TRACKING ANTENNAS AND
OTHERS ARE OMNIDIRECTIONAL. THE
FRESNEL ZONE CALCULATION: L, S, C, UHF,
VHF BANDS. ANTENNA WEIGHT IS
APPROXIMATELY 300 LBS. SEE ALSO DRAWING
S-001 NOTE 106.B LIVE LOADS.
GENERAL NOTES
IA
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
SHEET REFERENCE:
DA
TE
SHEET NUMBER:
OF
DE
SC
RI
PT
IO
N
RE
V
AI
R
FO
RC
E
SP
EC
IA
L
OP
ER
AT
IO
NS
C
OM
M
AN
D
1 S
PE
CIA
L O
PE
RA
TIO
NS
CI
VIL
EN
GIN
EE
R S
QU
AD
RO
N
HU
RL
BU
RT
F
IE
LD
, F
LO
RI
DA
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-003
5/26/20
TO
W
ER
P
LA
CE
ME
NT
CBM
PDR
CP1028223
AL
TE
R
IN
TE
R
IO
R
E
XT
ER
IO
R
BL
D G
PLAN
NORTH
1" = 30'-0"A-003
1 TOWER PLACEMENT PLAN
SCALE: 1" = 30'-0"
0 15' 30'
3/4
/22
AM
EN
D
AR0016090
DERETSI
GE
R
ARCH ITEC
T
FOETATS
FLORIDA
L
IN
DA
CAROL SAWYER
3/4/22
A
C
D
B
E
EXISTINGNEW WORK
REMOVE PLUMBING FIXTURES AND
CAP UTILITIES, TYP.
REMOVE CLOSET WALLS AND DOORS.
PATCH AND REPAIR REMAINING
SURFACES, TYP.
REMOVE TOILET ROOM WALLS AND
DOORS. PATCH AND REPAIR REMAINING
SURFACES, TYP.
14'-3" 21'-0"
REMOVE EXISTING WALL.
PATCH AND REPAIR
REMAINING SURFACES.
REMOVE EXISTING
DOOR. INFILL WALL AND
PREP FOR NEW WORK.
REMOVE INTERIOR
GYPSUM WALL BOARD
AND STUD LAYER, TYP.
REMOVE EXISTING INTERIOR GYPSUM WALLBOARD & TILE
WAINSCOT, PREP FOR NEW WORK
REMOVE EXISTING DOOR,
PREP FOR NEW WORK
REMOVE EXISTING DOOR,
FRAME TO REMAIN. PREP
FOR NEW WORK
REMOVE EXISTING DOORS.
PREP FOR NEW WORK
REMOVE WALL, PREP
SURFACES FOR NEW WORK
REMOVE EXISTING
DOOR, PREP FOR NEW
WORK
REMOVE EXISTING DOORS.
PREP FOR NEW WORK
FHC
91011121314151617
USE SAWCUT TECHNIQUE
TO REMOVE SLAB TO
EXTENTS REQUIRED FOR
PLUMBING WORK. PREP
SURFACES FOR NEW WORK.
EXISTING CONCRETE COLUMN TO REMAIN
79'-8" 39'-1"
'-4
101'-4"
DEMO EXISTING
CONCRETE AS
REQUIRED FOR
NEW RAMP
4' -1
1. THE GOVERNMENT WILL REMOVE EQUIPMENT PRIOR
TO THE BUILDING DEMOLITION.
2. GENERAL DEMOLITION WORK TO THE EXISTING
BUILDING FOR THE INSTALLATION OF NEW UTILITIES
AND SERVICES SHALL BE INCLUDED IN THE SCOPE OF
WORK. SAW-CUTTING AND EXCAVATION; FILLING AND
PATCHING OF EXISTING CONCRETE FLOOR SLABS TO
REMAIN AFTER INSTALLATION OF NEW UTILITIES AND
SERVICES SHALL ALSO BE INCLUDED IN THE SCOPE OF
WORK. REFER TO PLUMBING AND ELECTRICAL
DRAWINGS FOR NEW UTILITIES AND SERVICES.
3. PATCHING OF EXISTING STUD WALLS AND GYPSUM
WALLBOARD TO REMAIN SHALL ALSO BE INCLUDED IN
SCOPE OF WORK.
4. REFER TO ELECTRICAL, PLUMBING AND MECHANICAL
DRAWINGS FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
5. DEMOLISH PORTION OF EXISTING WALLS TO
ACCOMMODATE NEW DUCTWORK, PIPING, CONDUITS,
ETC. REFER TO MECHANICAL, ELECTRICAL, PLUMBING
AND FIRE PROTECTION DRAWINGS.
DEMOLITION NOTES
EXISTING DOOR TO REMAIN
REMOVE EXISTING DOOR,
FRAME AND HARDWARE
REMOVE EXISTING
CONSTRUCTION
EXISTING CONSTRUCTION TO
REMAIN
GRAPHIC LEGEND
FIRE HOSE CABINET TO REMAINFHC
FIELD VERIFY
EXISTING CONCRETE
COLUMN TO REMAIN
EXISTING CMU WALL TO REMAIN
CLEAN GROUT FROM OPENING,
TYP. EACH SIDE
REMOVE EXISTING DOOR,
SIDELITE, AND FRAME COMPLETE.
PREP FOR NEW DOOR
THE INTERIOR GYPSUM BOARD FACE OF THE EXTERIOR
WALL IS TO BE REMOVED. REMOVE STUD FRAMING
COMPLETE. PROVIDE NEW STUD FRAMING AND GYPSUM
BOARD. INTERIOR WALL PLANES TO BE NEW GYPSUM
BOARD CONSTRUCTION.
EXTERIOR WALL DEMO
NOTE
REMOVE GYPSUM WALLBOARD
REMOVE WOOD FURRING
REMOVE CMU
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-101
5/26/20
1S T
F
LO
O R
D E
M O
P
LA
N
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
PLAN
NORTH
1/8" = 1'-0"A-101
1 FIRST FLOOR DEMO PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
1 1/2" = 1'-0"A-101
3 EXTERIOR DOOR DEMO
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
1 1/2" = 1'-0"A-101
2 TYPICAL EXISTING INTERIOR WALL
A
C
D
B
E
RADIO & EQUP.
LAB
CORRIDOR
CONF.
OFFICE
FRONT OFFICE
MECH.
UNISEX
UNISEX
E
A-401
BREAK
ELEC/ COMM
112111 A-450
INFILLED WINDOWS, TYP.
A-501
A-501
A-501
A-501
5'- 5"
STOR.
101B
CELL PHONE
LOCKERS
FHC
E
A-310
5 A-501
A-501
6 6
INFILLED WINDOWS, TYP.
EXISTINGNEW WORK
101A
TYP.
91011121314151617
SEE SHEET A-003 FOR
TOWER INFORMATION
6"
SQUARE
20'-2" 6"
CORRIDOR
6"
A-4505
5 5
EQ
'-2
EQ
EQ 12'-2" EQ
2"
5'-6"
6'- 0"
TYP.
A-601
A-110
NOTE:
TOWER POSITION IS APPROXIMATE
AND CAN BE ADJUSTED AS NEEDED.
FIELD VERIFY
FLOOR PLAN NOTES
1. SEE SHEET A-002 FOR WALL CONSTRUCTION LEGEND.
2. PROVIDE GYPSUM WALLBOARD CONTROL JOINTS @
30'-0" OC MAX. PROVIDE CONTROL JOINTS AT EACH
SIDE OF DOOR OPENINGS FROM THE HEADER TO THE
TOP OF THE WALL. ATTACH CONTROL JOINT TO
DOUBLE STUDS SPACED 1/2" APART.
3. PROVIDE BLOCKING IN WALLS FOR CORNER GUARDS,
TV BRACKETS, TOILET ACCESSORIES, AND OTHER
WALL MOUNTED ITEMS.
4. REFER TO WALL SECTIONS AND PLAN DETAILS FOR
SPECIFIC WALL DIMENSIONS TO COLUMN LINE AND
EXISTING CONSTRUCTION.
5. PLAN DRAWINGS ARE GENERATED BY A CUT
THROUGH THE WALL AT A HEIGHT OF
APPROXIMATELY 48”. COMPONENTS IN OR ON THE
WALL ABOVE OR BELOW THIS PLANE MAY NOT BE
IDENTIFIED IN THIS PLAN VIEW. SEE ELEVATION
VIEWS FOR IDENTIFICATION OF ALL WALL
COMPONENTS AND OPENINGS.
6. ALL DIMENSIONS ARE FROM FACE OF CMU, FACE OF
STUD, OR WHERE APPLICABLE, COLUMN GRIDLINE.
GRAPHIC LEGEND
ROOM NAME / NUMBER
DESIGNATION101
ROOM NAME
EXTENT OF NEW WORK
DOOR NUMBER
WALL TYPE
ACCESS CONTROL DOOR
REF REFRIGERATOR, GF/GI
S SINK
NEW WALL CONSTRUCTION, SEE WALL
CONSTRUCTION LEGEND, SHEET A-000
EXISTING WALL
SECURE AREA LIMITS "A"
EXISTING DOOR TO REMAIN
2 HOUR FIRE RATED WALL
E EXIT ONLY DOOR
FIELD VERIFY
EXISTING CONCRETE COLUMN TO REMAIN
EXISTING CMU WALL TO REMAIN
3 EACH - 3/8" DOWEL ANCHOR @ 24" APART
3 EACH MASONRY JAMB ANCHOR
STC 50 ACOUSTIC RATED HM DOOR
FRAME ASSEMBLY WITH PAINTED FINISH
ACOUSTIC SEAL
HARDWARE AT INTERIOR ONLY. SEE
HARDWARE SCHEDULE FOR
COMPLETE HARDWARE LIST
GROUT FRAME
3 EACH - 3/8" PIN HEAD
WEDGE ANCHOR
GROUT FRAME
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD @ 16" O.C.
EXISTING CONCRETE
COLUMN TO REMAIN
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD @ 16" O.C.
FILL CAVITY WITH
ACOUSTICAL INSULATION
FILL CAVITY WITH
ACOUSTICAL INSULATION
PAINTED FINISH TO MATCH
ADJACENT SURFACES
IA
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
SHEET REFERENCE:
DA
TE
SHEET NUMBER:
OF
DE
SC
RI
PT
IO
N
RE
V
AI
R
FO
RC
E
SP
EC
IA
L
OP
ER
AT
IO
NS
C
OM
M
AN
D
1 S
PE
CIA
L O
PE
RA
TIO
NS
CI
VIL
EN
GIN
EE
R S
QU
AD
RO
N
HU
RL
BU
RT
F
IE
LD
, F
LO
RI
DA
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-110
5/26/20
1S T
FL
OO
R
PL
AN
CBM
PDR
CP1028223
AL
TE
R
IN
TE
R
IO
R
E
XT
ER
IO
R
BL
D G
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
PLAN
NORTH
1/8" = 1'-0"A-110
1 FIRST FLOOR PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
1 1/2" = 1'-0"A-110
2 EXTERIOR DOOR DETAIL
3/4
/22
AM
EN
DM
EN
T
AR0016090
DERETSI
GE
R
ARCH ITEC
T
FOETATS
FLORIDA
L
IN
DA
A
C
D
B
E
91011121314151617
EXISTINGNEW WORK
REMOVE EXISTING LIGHT FIXTURE, TYP.
1 1
1 1 1
11 1111
1 1 1
REMOVE EXISTING TILES AND GRID
AS REQUIRED TO INSTALL NEW
DUCTWORK (SEE MECHANICAL)
REMOVE EXISTING
CONSTRUCTION (AS INDICATED
WITH DASHED LINES)
EXISTING CONSTRUCTION TO
REMAIN (AS INDICATED WITH
LIGHT SOLID LINES)
GRAPHIC LEGEND
REMOVE EXISTING 2 X 4 LIGHTING
FIXTURE, SEE ELECTRICAL DRAWINGS
REMOVE EXISTING 2 X 2 LIGHTING
FIXTURE, SEE ELECTRICAL DRAWINGS
REMOVE EXISTING CEILING1
1. THE GOVERNMENT WILL REMOVE EQUIPMENT PRIOR
TO THE BUILDING DEMOLITION.
2. GENERAL DEMOLITION WORK TO THE EXISTING
BUILDING FOR THE INSTALLATION OF NEW UTILITIES
AND SERVICES SHALL BE INCLUDED IN THE SCOPE OF
WORK. SAW-CUTTING AND EXCAVATION; FILLING AND
PATCHING OF EXISTING CONCRETE FLOOR SLABS TO
REMAIN AFTER INSTALLATION OF NEW UTILITIES AND
SERVICES SHALL ALSO BE INCLUDED IN THE SCOPE OF
WORK. REFER TO PLUMBING AND ELECTRICAL
DRAWINGS FOR NEW UTILITIES AND SERVICES.
3. PATCHING OF EXISTING STUD WALLS AND GYPSUM
WALLBOARD TO REMAIN SHALL ALSO BE INCLUDED IN
SCOPE OF WORK.
4. REFER TO ELECTRICAL, PLUMBING AND MECHANICAL
DRAWINGS FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
5. DEMOLISH PORTION OF EXISTING WALLS TO
ACCOMMODATE NEW DUCTWORK, PIPING, CONDUITS,
ETC. REFER TO MECHANICAL, ELECTRICAL, PLUMBING
AND FIRE PROTECTION DRAWINGS.
DEMOLITION NOTES
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-150
5/26/20
1S T
F
LO
O R
C E
IL
IN
G D
E M
O
LI
T
IO
N P
LA
N
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
PLAN
NORTH
1/8" = 1'-0"A-150
1 FIRST FLOOR DEMO CEILING PLAN
A
C
D
B
E
7'-6"
7'-6"
8'-0"
7'-6"
OFFICE
CONF.
RADIO & EQUP.
LAB
CORRIDOR
FRONT OFFICE
ELEC/ COMM
MECH.
UNISEX
UNISEX
BREAK
STOR.
91011121314151617
EXISTINGNEW WORK
7'-6"
7'-6"
8'-0"
CORRIDOR
EXISTING LIGHT FIXTURES,
SPRINKLERS, DETECTORS, EXIT
SIGNAGE, ETC. SHALL BE
REINSTALLED AT NEW CEILING
7'-6"
A-151
PROVIDE NEW BULKHEAD
1. ALL CEILING HEIGHTS ARE 8'-8" UNLESS NOTED
OTHERWISE.
2. VERIFY EXACT LOCATION OF VIDEO PROJECTORS PRIOR
TO INSTALLING ANY WORK FOR THIS EQUIPMENT,
INCLUDING POWER AND DATA.
3. ALL FIRE SPRINKLER HEADS, ELECTRICAL FIXTURES AND
MECHANICAL VENTS SHALL BE CENTERED WITHIN
CEILING TILES UNLESS NOTED OTHERWISE.
4. USE MANUFACTURER'S STANDARD FOR ALL CEILING
ELEVATION TRANSITION.
CEILING NOTES
GRAPHIC LEGEND
2' X 2' SUSPENDED ACOUSTICAL
TILE LAY-IN CEILING WITH GRID
2 X 4 LIGHTING FIXTURE, SEE
ELECTRICAL DRAWINGS
CEILING DIFFUSER, SEE
MECHANICAL DRAWINGS
RETURN AIR GRILLE, SEE
MECHANICAL DRAWINGS
EXIT LIGHT, SEE ELECTRICAL AND
LIFE SAFETY DRAWINGS FOR
DIRECTIONAL INFORMATION
CEILING EXHAUST, SEE
MECHANICAL DRAWINGS
S
S
FIRE ALARM / MASS NOTIFICATION
SYSTEM FLUSH MOUNTED CEILING
SPEAKER, SEE ELECTRICAL DRAWINGS
FIRE ALARM / MASS NOTIFICATION
SYSTEM FLUSH MOUNTED CEILING
SPEAKER WITH STROBE, SEE
ELECTRICAL DRAWINGS
IR
INTRUSION ALARM SYSTEM PASSIVE
INFRARED DETECTOR, SEE
ELECTRICAL DRAWINGS
OS
LIGHTING CONTROL CEILING MOUNTED
SENSOR, SEE ELECTRICAL DRAWINGS
CEILING HEIGHT
ROOM NUMBER DESIGNATION
LIGHTING FIXTURE, SEE ELECTRICAL
DRAWINGS
8'-8"
OPEN TO STRUCTURE ABOVE
2 X 2 LIGHTING FIXTURE, SEE
ELECTRICAL DRAWINGS
EXTERIOR WALLPACK LIGHT, SEE
ELECTRICAL DRAWINGS
6"
3-5/8" GYPSUM WALLBOARD 6"
M
IN
6" M
IN
3-5/8" 22 GA. GALV. METAL STUD
ACT SYSTEM, TYP.
3-5/8" 22 GA. GALV. STUD BRACING
BACK TO STRUCTURE OR DECK
ALIGN FACE OF NEW GYPSUM
WALLBOARD BULKHEAD WITH
EXISTING GYPSUM WALLBOARD
AT COLUMN BEYOND
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-151
5/26/20
C E
IL
IN
G P
LA
N
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
PLAN
NORTH
1/8" = 1'-0"A-151
1 FIRST FLOOR CEILING PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
1 1/2" = 1'-0"A-151
2 BULKHEAD DETAIL @ ACT
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
EXISTING BUILDING
STRUCTURE TO REMAIN
APPLY OPAQUE BLACK
FILM TO INSIDE FACE OF
EXISTING GLASS
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD @ 16" O.C.
EXISTING WINDOW
SYSTEM TO REMAIN
APPROXIMATE LINE OF
EXISTING GRADE
EXISTING BUILDING
STRUCTURE TO REMAIN
EXISTING FOUNDATION
TO REMAIN
STUD PLANE TO JUST
TOUCH SILL PIECE
'-5
2' X 2' SUSPENDED
ACOUSTICAL CEILING AS
SCHEDULED
FASTEN TRACK @ 32" O.C. MAX
FASTEN TRACK @ 32" O.C. MAX
FIRST FLOOR
0' - 0"
SECOND FLOOR
10' - 0"
EXISTING BUILDING
STRUCTURE TO REMAIN
FILL CAVITY WITH
ACOUSTICAL INSULATION
PROVIDE WIRE AS
NEEDED TO SUPPORT
INSULATION
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-310
5/26/20
W A
LL
S
E C
T
IO
N S
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
1 1/2" = 1'-0"A-310
1 WINDOW INFILL DETAILS
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
F
A
BC
E
E
F
G
G
A
B
7'-0"
7' -9
A-501
8 A-501
CD
D
UNISEX
UNISEX
STOR.
CORRIDOR
1' -0
M A
X
M
IN
M A
X
18"
B
E A B
D
D
8" MIN.
17" MIN.
F
CLEAR KNEE
SPACE
36" MIN.
MAX.
6"
A C
D
MAX.
12" 42" MIN.
54" MIN.
B
STANDARD STALL ACCESSIBLE STALL
C
7" - 9"
/2
ACCESSIBLE STALL
E
1' -4
7" - 9"
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-401
5/26/20
E N
LA
R
G E
D P
LA
N
S
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
PLAN
NORTH
1/2" = 1'-0"A-401
1 ENLARGED TOILET ROOM PLAN
SCALE: 1/2" = 1'-0"
0 1' 2' 4'
3/8" = 1'-0"A-401
2 TYPICAL MOUNTING HEIGHTS
SCALE: 3/8" = 1'-0"
0 1'-4" 2'-8" 5'-4"
ACCESSORY SCHEDULE
MARK ITEM/DESCRIPTION ABBREV. MFR. MODEL REMARKS
A 36" GRAB BAR GB1 BOBRICK B-6806 X 36
B 42" GRAB BAR GB2 BOBRICK B-6806 X 42
C DUAL ROLL TOILET TISSUE DISPENSER TTD BOBRICK B-2740
D SANITARY NAPKIN DISPOSAL SND BOBRICK B-270
E WARDROBE HOOK WH BOBRICK B-212
F 24" X 36" MIRROR MR BOBRICK B-165 2430
G SOAP DISPENSER SD BOBRICK B-5050
A-450
A-450
2' -1
0" 4'
-0
3'-0"2'-0"3'-0"
REFRIGERATOR, GF/GI
SOLID SURFACE
COUNTERTOP
3/4" PLASTIC
LAMINATE SHELF
3/4" PANEL WITH PLASTIC
LAMINATE FINISH
4" 4"
2'-0" 3'-0"
2' -6
MICRO
OPEN
A-450
SINK, SEE PLUMBING
1/2" THICK SOLID SURFACE
COUNTERTOP, SEE INTERIORS.
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE INTERIORS
1/2" PANEL WITH
LAMINATE CABINET LINER
WIRE PULL, TYP.
6" 1'
-1 0"
4"
2' -1
0"
3"
SEALANT 4"
1/2"PT 1X WOOD FRAMING TO
SUPPORT COUNTERTOP
2'-0"
1/2" PANEL WITH CABINET LINER
1'-2"
3/4" PANEL SHELF W/ PLASTIC
LAMINATE FINISH ON ADJUSTABLE
SHELF STANDARDS, SEE I-120
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE
INTERIORS, I-120
3"
1/2" THICK SOLID SURFACE
COUNTERTOP AND
BACKSPLASH, SEE INTERIORS.
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE INTERIORS
1/2" PANEL WITH LAMINATE
CABINET LINER
3/4" PLASTIC LAMINATE SHELF ON
ADJUSTABLE SHELF STANDARDS
PT 1X WOOD FRAMING TO
SUPPORT COUNTERTOP
1/2"
6" 1'
-1 0"
4"
SEALANT
WIRE PULL, TYP.
SOLID WOOD DRAWER CONSTRUCTION
ON HEAVY DUTY DRAWER SLIDES
2' -1
0"
4"
2'-0"
1/2" PANEL WITH CABINET LINER
1'-2"
3/4" PANEL SHELF W/ PLASTIC
LAMINATE FINISH ON ADJUSTABLE
SHELF STANDARDS, SEE I-120
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE
INTERIORS, I-120
3' -0
1'-6"
CELL PHONE LOCKERS (30 TOTAL)
7"H x 7"W x 8"D
POWDER COATED, SURFACE MOUNTED
LOCKER DOORS HAVE RESETTABLE
COMBINATION LOCKS & MASTER
CONTROL KEY (SALSBURY
INDUSTRIES OR EQUAL)
3"
1/2" THICK SOLID SURFACE
COUNTERTOP AND
BACKSPLASH, SEE INTERIORS.
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE INTERIORS
1/2" PANEL WITH LAMINATE
CABINET LINER
3/4" PLASTIC LAMINATE SHELF ON
ADJUSTABLE SHELF STANDARDS
PT 1X WOOD FRAMING TO
SUPPORT COUNTERTOP
1/2"
6" 1'
-1 0"
4"
SEALANT
WIRE PULL, TYP.
SOLID WOOD DRAWER CONSTRUCTION
ON HEAVY DUTY DRAWER SLIDES
2' -1
0"
4"
2'-0"
3/4" PANEL WITH PLASTIC
LAMINATE FINISH, SEE
INTERIORS
3/4" PLASTIC LAMINATE SHELF ON
ADJUSTABLE SHELF STANDARDS
1'-6"
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-450
5/26/20
C A
S E
W O
R K
E
LE
V A
T
IO
N S
A N
D S
E C
T
IO
N S
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
3/8" = 1'-0"A-450
1 CASEWORK ELEVATION
SCALE: 1" = 1'-0"
0 6" 1' 2'
1" = 1'-0"A-450
2 CASEWORK SECTION
1" = 1'-0"A-450
3 CASEWORK SECTION
3/8" = 1'-0"A-450
5 CELL PHONE LOCKER ELEVATION
SCALE: 3/8" = 1'-0"
0 1'-4" 2'-8" 5'-4"
1" = 1'-0"A-450
4 CASEWORK SECTION
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD
EXISTING COLUMN
LEAVE ROOM FOR
EXISTING VARIATION
B
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD
EXISTING COLUMN
3 5/8" METAL STUDS @ 16" O.C.
LEAVE ROOM FOR
EXISTING VARIATION
CORRIDOR
BREAK
B
EXISTING CONCRETE COLUMN
1 5/8" METAL STUD
UNISEX
BREAK
5/8" GYPSUM WALLBOARD
3 5/8" METAL STUD @ 16" O.C.
LEAVE ROOM FOR
EXISTING VARIATION
FILL CAVITY WITH
ACOUSTICAL INSULATION
CORRIDOR
B
125/8" GYPSUM WALLBOARD
1 5/8" METAL STUD
EXISTING COLUMN
LEAVE ROOM FOR
EXISTING VARIATION
EXISTING WALL
EXISTING WALL
MECH.
CORRIDOR
C
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD
EXISTING COLUMN
3 5/8" METAL STUDS @ 16" O.C.
FILL CAVITY WITH
ACOUSTICAL INSULATION
LEAVE ROOM FOR
EXISTING VARIATION
C
5/8" GYPSUM WALLBOARD
1 5/8" METAL STUD
EXISTING COLUMN
3 5/8" METAL STUDS @ 16" O.C.
FILL CAVITY WITH
ACOUSTICAL INSULATION
12 LEAVE ROOM FOR
EXISTING VARIATION
D
EXISTING EXTERIOR WALL
5/8" GYPSUM WALLBOARD
3 5/8" METAL STUD @ 16" O.C.
1 5/8" METAL STUD @ 16" O.C.
RADIO & EQUP.
LAB
CONF.
FILL CAVITY WITH
ACOUSTICAL INSULATION
LEAVE ROOM FOR
EXISTING VARIATION
FILL CAVITY WITH
ACOUSTICAL INSULATION
D
1 5/8" METAL STUD @ 16" O.C.
FILL CAVITY WITH
ACOUSTICAL INSULATION
5/8" TYPE "X" GYPSUM
WALL BOARD
EXISTING WALL
SURFACE MOUNTED CELL
PHONE LOCKERS, INSTALL
PER MANUFACTURER
STANDARD
HOLLOW METAL DOOR
FRAME, PAINTED
45 MIN. RATED STC 50
WOOD DOOR
SOUND STOP
LEAVE ROOM FOR
EXISTING VARIATION
RADIO & EQUP.
LAB
AR94997
DERETSI
G
E R
A R C H
IT
E C
T
FOETAT
S
FL O R ID
A
R ICE
ACREBO
R
RLT
05/26/20
IA
R
E
OF
RC
SP
EC
IA
AN
N
P
ER
L O
A
TI
O
M M
S
CO
D
SHEET REFERENCE:
D A
T E
SHEET NUMBER:
OF
D E
S C
R
IP
T
IO
N R
E V
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
S
P
EC
IA
L
O
PE
R A
TI
O
N S
C
IV
IL
E
N G
IN
E
ER
S
Q U
A D
R O
N
H U
R
LB
U R
T
FI
EL
D
, F
LO
R
ID
A
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
90322
A-501
5/26/20
P
LA
N D
E T
A
IL
S
CBM
PDR
CP1028223
A L
T E
R I
N T
E R
IO
R
E
X T
E R
IO
R
B
L D
G
1 1/2" = 1'-0"A-501
1 TYPICAL COLUMN DETAIL
1 1/2" = 1'-0"A-501
4 COLUMN DETAIL
1 1/2" = 1'-0"A-501
8 CHASE WALL DETAIL
1 1/2" = 1'-0"A-501
5 COLUMN DETAIL
1 1/2" = 1'-0"A-501
3 COLUMN DETAIL
1 1/2" = 1'-0"A-501
2 COLUMN DETAIL
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
1 1/2" = 1'-0"A-501
6 EXISTING WALL CORNER DETAIL
1 1/2" = 1'-0"A-501
7 DETAIL AT CELL PHONE LOCKERS
SE
E
SC
HE
D
SEE SCHED
SOLID CORE WOOD
(SCWD) DOOR
(A)
DOOR ELEVATIONS
SE
E
SC
HE
D
SEE SCHED
INSULATED HOLLOW METAL
(HM) DOOR
(B)
HOLLOW METAL
(HM) FRAME
(1)
SEE SCHED
SE
E
SC
HE
D
2" 2"
2"
DOOR FRAME ELEVATIONS
HARDWARE SCHEDULE
HARDWARE SET 1 - DOOR 101A LAB, 104, 112
3 EA HINGES A8112
1 EA LOCKSET F04
2 EA LEVER HANDLES
1 EA WALL STOP L02101
1 SET SILENCERS L03011
2 EA KICKPLATES J103
HARDWARE SET 2 - DOOR 101B EXIT ONLY STC 50
3 EA CAM HINGES ZERO Z950 OR EQUAL
1 EA ARMED EXIT DEVICE TYPE 1, F01, E01 VON DUPRIN OR EQUAL
1 EA CLOSER C02021
1 SET HEAD/JAMB GASKET R3B264
1 EA AUTOMATIC DOOR BOTTOM R3B334
1 EA THRESHOLD J36130
1 EA SPRING DOOR SEAL R1K155
2 EA KICKPLATE 10"X34" J102
NOTE:
1. COORDINATE WITH ELECTRICAL DRAWINGS FOR ELECTRONIC SYSTEMS
2. STC MANUFACTURER SHALL PROVIDE A RATED ASSEMBLY THAT INCLUDES THE DOOR,
FRAME, GASKETING AND HINGES. HARDWARE LISTED AS A GUIDE ONLY. DOOR/FRAME
MANUFACTURER MAY REQUIRE THE USE OF OTHER HARDWARE TYPES/ITEMS IN ORDER TO
MEET STC RATING APPLICABLE TO OPENINGS. MANUFACTURER MUST INCLUDE COST OF
REQUIRED HARDWARE AS BASIS OF BID. FINAL INSTALLED ASSEMBLY MUST MEET STC
RATING INDICATED.
HARDWARE SET 3 - DOOR 103 STC 50
3 EA CAM HINGES ZERO Z950 OR EQUAL
1 EA HIGH SECURITY EXIT DEVICE 2890B AMM 3 TYPE IV CDX10; SELF POWERED
SPIN DIAL; PANIC FUNCTION; GSA CERTIFIED, FF-L-2890B
W/ DUAL RING MOUNTING PLATE & STRIKE
1 EA ELECTRIC POWER TRANSFER VON DUPRIN EPT2 OR EQUAL
1 EA CLOSER C02021
1 SET HEAD/JAMB GASKET R3B264
1 EA AUTOMATIC DOOR BOTTOM R3B334
1 EA THRESHOLD J36130
1 EA SPRING DOOR SEAL R1K155
1 EA STOP L02101
1 EA ACCESS CONTROL GFGI - CONTRACTOR TO PROVIDE ADAPTABLE STRIKE &
INFRASTRUCTURE
2 EA KICKPLATE 10"X34" J102
NOTE:
1. COORDINATE WITH ELECTRICAL DRAWINGS FOR ANY ELECTRONIC SYSTEMS
2. STC MANUFACTURER SHALL PROVIDE A RATED ASSEMBLY THAT INCLUDES THE DOOR,
FRAME, GASKETING AND HINGES. HARDWARE LISTED AS A GUIDE ONLY. DOOR/FRAME
MANUFACTURER MAY REQUIRE THE USE OF OTHER HARDWARE TYPES/ITEMS IN ORDER TO
MEET STC RATING APPLICABLE TO OPENINGS. MANUFACTURER MUST INCLUDE COST OF
REQUIRED HARDWARE AS BASIS OF BID. FINAL INSTALLED ASSEMBLY MUST MEET STC
RATING INDICATED.
3. HIGH SECURITY EXIT DEVICE WITH CDX10 OR EQUAL IS TO BE INSTALLED BY
FACTORY TRAINED AND CERTIFIED PERSONNEL.
4. SEQUENCE OF OPERATION: DOOR IS NORMALLY CLOSED AND LOCKED. HIGH SECURITY
DEAD BOLT IS UNLOCKED WITH A VALID COMBINATION. IN THE EVENT OF A POWER FAILURE, THE
OPENING WILL REMAIN SECURE. FREE EGRESS AT ALL TIMES.
HARDWARE SET 4 - DOOR 105, EXIT ONLY AT EXTERIOR
3 EA CAM HINGES ZERO Z950 OR EQUAL
1 EA ARMED EXIT DEVICE TYPE 1, F01, E01 VON DUPRIN OR EQUAL
1 EA CLOSER C02021
1 SET HEAD/JAMB GASKET…
This is the start of the file's text. The full file is on GovTribe.