This is a Statement of Need for the 502 Communications Squadron at JBSA-Lackland that specifies materials required for relocating government infrastructure to support a city project.

The procurement is limited to the supply and delivery of materials only, with no installation, testing, splicing, or site preparation services required. All materials must be brand name or equal and meet specified salient characteristics. The materials fall into two primary categories: copper communications infrastructure and fiber optic infrastructure components. Copper cable requirements include 2,000 feet of Superior Essex 600-pair 24-gauge shielded copper cable. Fiber optic requirements include 5,500 feet of Corning 288-fiber singlemode cable, 4,144 feet of Corning ALTOS 72-fiber singlemode cable, two Corning CCH-04U closet connector housings, 26 CCH splice cassettes, and associated hardware including grommet kits, dome closures, and splice trays from Preformed Line Products (PLP COYOTE systems) and stainless steel armadillo splice cases. The procurement also includes consumable supplies such as electrical tape, flexible fabric innerduct with tracer wire, cable markers, industrial labeling tape, UV-stabilized cable ties in 14-inch and 24-inch lengths, heat-shrink splice protection sleeves, cleaning wipes and solvents, connector cleaning tools, duct seal compound, underground cable rack hooks, 25-pair splice connectors, field cleaning wipes, pull tape, a cable pulling swivel, and various other installation consumables totaling quantities ranging from 1 to 6,000 feet depending on the item.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Need – 502 Communications Squadron JBSA-Lackland SCOW

1.0 General Information.

1.1 Scope: The contractor shall provide and deliver all necessary materials, equipment, and consumables specified. No installation, testing, splicing, or site preparation services are required under this SOW. The primary objective is strictly the procurement and delivery of materials. All materials must be "brand name or equal" and meet or exceed the salient characteristics listed in the requirement.

1.2 Background: The 502 Communication Squadron is in dire need of the list of material below. The material is for the relocation of the government infrastructure in the pathway in support of a city project.

1.3 Essential / Salient Characteristics:

All materials below Brand Name, therefore all items must meet the salient characteristic.

PART NUMBER MANUFACTURE/Part Name SALIENT CHARACTERISTIC QUANTITY

DB-600P24-AL-

89-ESS-CUT

REEL

Superior Essex - 600 Pair 24 Gauge Copper Cable

Copper Cable, 24 AWG, Shielded, Polyethylene, 600, Black (Jacket), 1250 Feet per Reel, Inhibits Corrosion, Moisture-Resistant

2000 FT

CCH-04U

Corning - Closet Connector Housing (CCH) Four Rack Units, holds 12 CCH Connector Panels

Closet connector housings (CCHs) provide interconnect or cross-connect capabilities between outside plant, riser or distribution cables and opto-electronics. Like other LANscape solutions hardware, the housings accept CCH connector panels. In addition, the housings accept CCH cassettes and CCH modules.From fiber and cable routing and strain relief, to port labeling and termination, these housings reduce the risk of error that can disrupt networks. The units are designed for rack mounting in 19-in (48 cm) racks or optional 23-in (58

cm) equipment racks (1.75-in EIA hole spacing). They are available in rack space options of 1U (two panels, cassettes or modules), 2U (four panels, cassettes or modules), 3U (six panels, cassettes or modules) and 4U (12 panels, cassettes or modules). The 1U, 2U and 3U options feature a slide-out tray and see-through, removable top covers.

The CCH-04U features a clear door, removable front and rear enclosures and a platinum-colored interior for maximum visibility and access.Every CCH housing is shipped complete with strain relief brackets, routing clips and guides, and mounting brackets for proper installation.

2 EA

CCH-CS24-A9-

P00RJ

Corning - CCH SPL CASSETTE SM 24F

LC-DUPLEX RIB

Closet Connector Housing (CCH) pigtailed splice cassettes enable faster field splicing and easy modular management of connectorization within the housing.

They are preloaded and pre-routed for quick fusion splicing of either individual or ribbon fiber pigtails, using the same space-saving platform as the standard CCH splice cassette. The pre-routed pigtailed cassettes reduce field labor by streamlining features and components to allow for efficiencies in the field. They are prepped with a 2 m pigtail assembly with all pre-existing CCH panel connector options. The pigtailed cassettes have colored 250 µm for ease of splicing.

They also enable strain relief to be pre-applied to the assemblies from the manufacturing facility. With the pigtailed cassette, individual splice tray or separate splice housings are eliminated, allowing splicing to be done away from the rack housing in more convenient workspaces. The modular design makes it easy to access the fiber in an individual cassette without disturbing the other fibers in the housing. Each cassette is shipped with the pigtailed CCH adapter panel of the customer’s

26 EA

choice, one rail for use with CCH- 01U/2U/3U housings, and two rails used with CCH-04U housings.

Grommets and cable ties for additional strain relief and protective braided tubing for incoming cables are also included. Splicing cassettes ship with the appropriate quantity and type of heat-shrink splice protectors.

8003691

PLP - Coyote Silicone Grommet kit(10.2- 15.2)

COYOTE Grommet Kit contains 1-entry grommet, (0.40 in. to 0.60 in.), one cable measure tape, two silicone lubricant packs, two sets of plugs and one plastic glove.

4 EA

8003692

PLP - Coyote Silicone Grommet Kit(15.2- 21.6)

Part number 8003692 refers to the Preformed Line Products (PLP) COYOTE® 1-Hole Silicone Grommet Kit. To qualify as an "or equal" substitute, an alternative must be a weather-resistant silicone grommet designed to seal a single fiber optic cable with a diameter of 0.60 to 0.85 inches, provide compatibility with PLP COYOTE closure systems, and meet GR-771- CORE standards for environmental sealing.

8006878

PLP - COYOTE Dome Closure for buffer tube (loose tube) applications - 6.5 in.x 22 in.

(165 mm x 589 mm)

The part number 8006878 refers to the Preformed Line Products (PLP) COYOTE® 6.5" x 22" Dome Closure Kit for Ribbon/Unitube Fiber Applications. To qualify as an "or equal" substitute, an alternative must be a re-enterable, hermetically sealed butt-splice dome enclosure (approx. 8.6" W x 22.6" L) designed with an organizer optimized for unitube/ribbon fiber storage and a 4-port segmented end plate supporting up to 648 ribbon splices. The kit must include two 0.40"–0.60" and two 0.60"–0.85" 1-hole grommets along with transit/transition tubing, and it must meet Telcordia® GR-771- CORE and IP-68 requirements for direct buried, underground, or aerial installations.

LGSTR144

PLP - COY RIB

LITE-GRIP

TRAY (SHORT)

The part number LGSTR144 refers to the Preformed Line Products

(PLP) COYOTE® LITE-GRIP®

Short Deep Profile Splice Tray Kit.

To qualify as an "or equal" substitute, an alternative must be a compact, deep-profile fiber splice tray equipped with four elastomer splice blocks capable of securing up to 144 ribbon/mass fusion splices. It must be fully compatible with PLP COYOTE

8 EA

closure systems and feature a flexible, slip-resistant grip design that safely secures standard ribbon splice protectors without damaging the optical fibers.

8006367

PLP -ARMADILLO Stainless Filling Flange Kits with Drillable End Plates - 6.5" x 38"

The part number 8006367 refers to the Preformed Line Products (PLP) ARMADILLO® Stainless Steel Splice Case with Filling Flange. To qualify as an "or equal" substitute, an alternative must be a re-enterable stainless steel splice enclosure designed for copper networks. It must feature an integrated bonding/grounding system, a filling flange/port for encapsulant compound injection, and utilize customizable drillable end plates rated for aerial, underground, or direct buried environments.

3 EA

All materials below are “brand name or equal”, therefore all items must meet the salient characteristic.

REFERENCE PART

NUMBER

Brand Name or Equal SALIENT CHARACTERISTIC QUANTITY

288EU4-T4700D20 (or Equal)

Corning – Fiber Optic Cable, Black, Singlemode (OS2), 288 Fiber, or equal

288-Fiber, Signlemode (OS2). SZ-stranded, loose-tube construction facilitating mid-span access. 100% all-dielectric construction requiring zero grounding or bonding infrastructure. Fully dry, gel-free water-swellable blocking technology. Outdoor-rated for lashed aerial and conduit/duct installation. Medium-Density Polyethylene (MDPE) outer jacket.

Proposed equal items must demonstrate full physical, mechanical, and optical equivalence. Offerors must provide manufacturer specification sheets verifying compliance with all salient characteristics.

5500 FT

072EU4-T4700D20

Corning - ALTOS® Loose Tube, Gel-Free, All-Dielectric Cable with FastAccess® Technology 72 F, Single-mode (OS2)

72-strand fiber optic cable, singlemode (OS2). Loose tube, SZ-stranded configuration supporting mid-span access. Fast-access cable jacket technology enabling jacket removal and reducing cable-end preparation time without specialized cutting tools.

Outdoor campus backbone rated for lashed aerial and duct/conduit installations. 100% All-Dielectric construction (non-metallic; requires no electrical bonding or grounding).

Gel-free, fully dry water-swellable materials. Rugged Medium-Density Polyethylene (MDPE), UV- and weather-resistant. Flexible, craft-friendly buffer tubes designed for standard splice tray and closure routing. Equivalent products must demonstrate identical or superior physical, mechanical, and optical performance. Offerors must provide manufacturer specification sheets verifying compliance with each salient characteristic listed.

4144 FT

3M Scotch® PN: 88-

SUPER-3/4X66FT

Heavy-Duty Premium Vinyl Electrical Tape

Dimensions: 3/4 in. (19 mm) width x 66 ft. (20 m) length.

• Thickness: Minimum 8.5-mil (0.216 mm) heavy-duty PVC backing (standard 7-mil not acceptable).

• Electrical Ratings: Rated for up to 600V; minimum dielectric strength of 10,000V.

• Temperature Range: All-weather operating temperature range of 0°F to 221°F (-18°C to 105°C).

• Certifications: UL 510 Listed and CSA C22.2 certified for flame retardance, UV resistance, and moisture/corrosion protection.

20 EA

MaxCell® Edge Detectable PN:

MXED64283GR2650

3-Inch, 3-Cell Detectable Flexible

Fabric Innerduct

• Design: Flexible fabric innerduct configured with 3 separate cells for installation in minimum 3.0 in. (75

mm) ID conduit.

• Capacity: Accommodates cable outer diameters up to 1.05 in. per cell.

• Material: Low-friction woven Polyester (PET)/Nylon fabric with high melting point (>400°F / 204°C) to withstand cable-pulling friction.

• Pull Tape: Pre-lubricated cells factory-equipped with color-coded, minimum 1,250 lb tensile strength pull tapes.

• Locatability: Integrated continuous minimum 18 AWG solid copper tracer wire for underground utility

6000 FT

locating.

• Put-Up: Supplied on continuous reels (minimum 2,650 ft).

AWG solid copper tracer wire for underground utility location, pre-lubricated cells with color-coded 1,250 lb pull tapes, and a high melting point of for durability during high-tension cable pulling.

Panduit® PN: PST-

FO

Self-Laminating Fiber Optic Cable

Marker Tag

• Dimensions: Approximately 3.5 in.

x 2.0 in. (88.9 mm x 50.8 mm).

• Material: Rigid, non-adhesive, UV-and weather-resistant vinyl tag.

• Mounting: Pre-cut mounting slots for cable tie attachment.

• Legend: High-visibility yellow background with black pre-printed legend: "CAUTION / FIBER OPTIC

CABLE / TYPE / COUNT".

• Protection: Integrated clear self-laminating protective flap that seals over handwritten/printed text to prevent moisture and abrasion damage.

• Temperature Rating:

Indoor/outdoor rated up to 176°F (80°C).

15 EA

Brother PN: TZE231

Industrial Laminated Labeling Tape (Black on White)

• Dimensions: 1/2 in. (12 mm / 0.47 in.) width x 26.2 ft. (8 m) length per cassette.

• Print Type: Thermal transfer black text on white background.

• Lamination: Multi-layer industrial laminated tape construction resistant to water, UV, chemicals, abrasion, and temperature extremes (-50°C to 150°C).

• Adhesive: Industrial-grade adhesive suitable for smooth, flat surfaces.

• Form Factor: Standard cassette compatible with industrial label printers accepting 12 mm cartridges.

5 EA

Uline / Panduit PN: S-

UV-Stabilized Heavy-Duty Nylon Cable

Ties (14-Inch)

• Dimensions: Nominal 14 in. length.

• Tensile Strength: Minimum 120 lb (534 N) loop tensile strength.

• Material: Weather-resistant, UV-stabilized Nylon 6/6; UL 94V-2 flame rated.

• Color: Black.

• Locking Mechanism: One-piece, tamperproof, non-releasable locking pawl preventing slipping or stretching.

• Temperature Range: Operating range of -40°F to 185°F (-40°C to 85°C); UL Listed for outdoor use.

Uline / Panduit PN: S-

UV-Stabilized Heavy-Duty Nylon Cable

Ties (24-Inch)

• Dimensions: Nominal 24 in. length.

• Tensile Strength: Minimum 120 lb (534 N) loop tensile strength.

• Material: Weather-resistant, UV-stabilized Nylon 6/6; UL 94V-2 flame rated.

12397 • Color: Black.

• Locking Mechanism: One-piece, tamperproof, non-releasable locking pawl preventing slipping or stretching.

• Temperature Range: Operating range of -40°F to 185°F (-40°C to 85°C); UL Listed for outdoor use.

AFL / Fujikura PN:

S003027 (FP-03

Series)

Single-Fiber Heat-Shrink Splice Protection Sleeves

• Application: Fusion splice protection for single optical fibers (standard 250 µm / 900 µm coated fibers).

• Length: Nominal 40 mm overall length.

• Construction: Three-part assembly comprising an outer heat-shrinkable polyolefin tube, an inner hot-melt ethylene vinyl acetate (EVA) adhesive tube, and a stainless steel strength member rod.

• Performance: Provides moisture sealing, strain relief, and mechanical rigidity across the splice point without inducing optical attenuation.

• Compatibility: Fits standard commercial splice trays and closure organizers.

150 EA

PT Technologies /

ITW D'GEL PN:

61244

Cable Gel / Degreaser Solvent Wipes

• Form: Pre-saturated lint-free heavy-duty wipes individually foil-packaged.

• Chemical Formulation: Non-aqueous, residue-free solvent specifically formulated to dissolve and strip petroleum-based cable gels ("icky-pic"), water-blocking gels, and pulling lubricants.

• Compatibility: Safe and non-damaging to cable jacketing, buffer tubes, individual fiber coatings, and metallic cable components.

• Safety: High flashpoint (>140°F / 60°C) with zero dielectric residue after drying.

2 EA

Jonard PN: FW-50

Pre-Saturated IPA Optical Cleaning Wipes

• Form: Pack of 50 individually wrapped or pop-up pre-moistened lint-free wipes.

• Solution Chemistry: 91% optical-grade Isopropyl Alcohol (IPA) and 9% deionized water.

• Performance: Non-abrasive, 100% residue-free cleaner that evaporates rapidly without streaking.

• Application: Safe for bare optical glass fiber, ceramic ferrules, and connector end-faces without cross-contamination.

7 EA

AFL / US Conec PN:

8500-05-0001MZ

Mechanical One-Click Fiber Connector

Cleaner (2.5mm)

• Ferrule Compatibility: Cleans standard 2.5 mm ceramic ferrule connector interfaces, including SC, ST, and FC styles (both UPC and APC polishes).

• Capability: Cleans unmated patch cord plugs as well as bulkhead adapter connectors inside distribution housings.

• Action: Mechanical push-action engagement with an audible click that rotates the cleaning tip while indexing fresh optical-grade dry cleaning ribbon.

• Capacity: Minimum 500+ cleaning cycles per unit.

• Design: Handheld pen-style tool requiring no external cleaning solvents.

6 EA

Ideal Industries PN:

31-605

Duct Seal Compound (5 lb Block)

• Form: 5 lb (2.27 kg) solid block.

• Material: Permanently soft, non-toxic, non-drying elastomeric putty compound; dark gray.

• Functional Properties: Moisture-proof, weather-resistant, non-hardening, non-corrosive, paintable, and adheres firmly to PVC, metal, conduit, wood, and masonry.

• Application: Seals cable conduit and duct terminations against water, drafts, dust, and pest intrusion.

12 EA

Hubbell / Chance PN:

C2031132

Underground Cable Rack Hook (7.5-Inch)

• Type: Heavy-duty cable support hook engineered to mount into standard underground/manhole T-slot cable rack channels.

• Length: Nominal 7.5 in. usable extension/bearing length.

• Material & Finish: High-strength ductile iron or structural steel, hot-dip galvanized per ASTM A153 for underground corrosion resistance.

• Design: Turned-up retention lip with smooth, rounded contours to

20 EA

prevent cable jacket abrasion.

3M PN: 710-SC1-25

25-Pair Straight Splice Connector Module (Gel- Filled)

• Type: 25-pair modular inline straight-through splice connector for multi-pair communications copper cables.

• Conductor Range: Accommodates 24 AWG to 26 AWG solid copper conductors with PIC, pulp, or paper insulation (up to 0.065 in. insulated

OD).

• Environmental Sealing: Factory pre-filled with moisture-resistant sealant/encapsulant gel to prevent corrosion and water intrusion.

• Construction: High-impact plastic casing with protective skirt enclosing trimmed conductor ends.

96 EA

Rainbow / Grime- Away PN: HTC-D72

Multi-Purpose Heavy-Duty Field Cleaning Wipes

• Dimensions: Nominal 10 in. x 12 in. per wipe.

• Packaging: Heavy-duty re-sealable canister/dispenser bucket containing 72 pre-moistened wipes.

• Formulation: Industrial field cleaner capable of dissolving grease, heavy grime, pulling lubricant, and cable gel without pumice or harsh petroleum distillates.

• Fabric: Dual-textured or heavy-duty lint-free non-woven fabric durable enough for rugged field utility work.

8 EA

Greenlee PN: 4436

Woven Polyester Measuring Pull Tape (1,800 lb / 3,000 ft)

Application : For Easily Pulling And

• Length: Continuous 3,000 ft. (914

m) length on a sturdy reel.

• Tensile Strength: Minimum 1,800 lb (8.01 kN) average breaking strength.

• Material: Continuous-filament woven high-strength polyester;

stretch-resistant and durable.

• Width: Nominal 5/8 in. (15.9 mm).

• Footage Markings: Sequentially marked footage printed clearly along the entire length for accurate distance verification.

• Friction: Pre-lubricated or low-friction weave to prevent conduit burn-through in PVC and HDPE innerducts.

MaxCell® PN:

MXCSW600

Ball-Bearing Underground Cable Pulling Swivel (600 lb)

• Rated Load Capacity: Minimum 600 lb (272 kg) safe working load.

• Outer Diameter: Slim profile with maximum outer diameter of 0.625

in. (5/8 in. / 15.9 mm) to prevent binding during tight conduit and innerduct pulls.

• Material: Precision-machined, corrosion-resistant stainless steel.

• Bearing Mechanism: Sealed internal ball bearings providing smooth 360-degree rotation under maximum tension to relieve cable twisting/torque.

• Connections: Replaceable clevis pins on both ends for rapid utility line attachment.

1 EA

File details come from the government source that posted it. Updated .