Attachments.pdf
PDF 4 MB Posted
- Attached to
- Penn Manor Large Valve Vault Replacement
- Solicitation number
- 120583
- Issued by
- Prince George's County, Maryland
About this file
This attachments file supports the Penn Manor Large Valve Vault Replacement contract opportunity for the Washington Suburban Sanitary Commission (WSSC) in Prince George's County, Maryland. The project involves replacing a 24-inch large valve vault and approximately 101 feet of 24-inch water main, relocating approximately 51 feet of 24-inch water main and approximately 54 feet of water house connections on Penn Manor Lane in Bowie. The Water and/or Sewerage Construction Permit (No. 22-11-1124) was issued on December 16, 2025, with an expiration date of December 16, 2028, authorizing construction in accordance with drawings numbered 1 through 6 and specifications. Sealed responses were due via WSSC's eProcurement Portal prior to 2:00 pm on Monday, November 16, 2026.
The attachments include supporting technical documents comprising soil boring logs, pavement core summaries, trench details for paved areas, valve location cards, and test pit results. Soil boring data indicates subsurface conditions including asphalt and concrete pavement layers overlying fill materials and native soils at varying depths and elevations. Pavement cores documented 3.0 inches of asphalt concrete and 3.5 inches of Portland cement concrete at the site location (16101 Penn Manor Lane, Bowie, Maryland). The Roadside Tree Care Maintenance Authorization (RTPA No. 2026-0127) permits pruning of two Norway Maple trees (one 18-inch diameter private tree and one 12-inch diameter public tree) to protect them during construction, with work performed by licensed tree care experts in compliance with Maryland Department of Natural Resources standards. All work must comply with WSSC standard details and specifications, with pavement restoration following Prince George's County Standard Detail STD. 300.18 or applicable jurisdictional requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENTS
a. Attachment Cover Sheet
b. Permits
c. Soil Boring Logs
d. Summary of Pavement Cores
e. Trench Detail
f. Valve Cards
g. Test Pit Results
Permits
WATER AND/OR SEWERAGE CONSTRUCTION PERMIT
Permit No.: 22-11-1124 Date Issued: 12/16/2025 Permit Fee: N/A Expiration Date: 12/16/2028
This permit authorizes the Washington Suburban Sanitary Commission to construct a large valve & valve vault replacement for a 24-inch water main together with all appurtenances, at the site of Penn Manor Lane, east of the intersection with Pinecroft Lane, Prince George’s County, in accordance with an application dated 11/08/2022 and received by the Maryland Department of the Environment on 11/10/2022 titled in part:
PENN MANOR LANE
LARGE VALVE VAULT REPLACEMENT
PRINCE GEORGE’S COUNTY
CONTRACT BT 7171 B21
DRAWINGS NOS. 1 THRU 6 OF 6, SC 1 AND SPECIFICATIONS
THIS PERMIT IS ISSUED SUBJECT TO THE ATTACHED FOLLOWING CONDITIONS:
Note: This permit may be suspended or revoked upon a final, unreviewable determination that the permittee lacks, or is in violation of federal, state or local approval necessary to conduct the activity authorized by this permit.
Walid Saffouri, P.E., Program Administrator Engineering & Capital Projects Program Water and Science Administration
GENERAL CONDITIONS FOR WATER OR SEWERAGE CONSTRUCTION PERMIT
- The structural adequacy and expected performance characteristics of the various components are not certified by this permit.
- This permit is not transferable.
- A copy of this permit must be posted at the work site during construction.
- This permit will expire, if not specifically extended, unless the construction authorized under this permit has been initiated. The permit will then remain valid for the remainder of construction for a period of up to five years from the start of construction.
- If any provision of this permit shall be held invalid for any reason, the remaining provisions shall remain in full force and effect, and such invalid provision shall be considered severed and deleted from this permit.
- Persons violating the requirements of this permit are subject to penalties of up to $1000 per day as set forth in Environment Article 9-268 and 9-334 through 9-342, Annotated Code of Maryland.
- A copy of the plans and specifications, authorized for use under this permit, shall be made available at the work site during construction of this project. A revised construction permit in accordance with COMAR
26.03.12 is required prior to making substantive changes or material alteration to the construction authorized under this permit.
- The owner shall secure all Federal, State or local permits, including approval of Sedimentation and Erosion Control Plans that may be required before starting the construction of the project.
- The owner shall insure that this project is inspected during the progress of construction to assure substantial compliance with the approved plans and specifications. A log and construction records shall be maintained by the inspector and may be requested for review at any time by this office.
- The project engineer of the Maryland Department of the Environment (the ‘Department’) shall be notified prior to the start of construction.
- Inspectors of the Department shall be afforded access to the project site, at reasonable times and upon presentation of credentials:
a. to inspect construction authorized under this permit and to determine compliance with applicable regulations;
b. to have access to and copy any records required to be kept by this permit and by applicable regulations;
and
c. to obtain any photographic documentation or evidence.
- Within 60 days after completion of construction, a copy of as-built drawings and the attached construction completion certificate (page 3 of this permit) shall be submitted to the Department. Where construction was completed in accordance with the original plans approved under this permit, the submittal of as-built drawings will not be required.
- The owner shall maintain a permanent record of the as-built drawings, or the original plans if as-built drawings are not required.
6/2022
NOTICE
Prior to starting construction, please notify John Gesswein, Project Engineer, by email at john.gesswein@maryland.gov. Upon completion of the project, the construction must be certified with the signed permit returned to this office along with a set of as-built drawings.
Should you have any questions concerning the permit or its conditions, please contact me at (410) 537-3757 or at walid.saffouri@maryland.gov.
Sincerely, Walid Saffouri, Program Administrator Engineering and Capital Projects Program Water and Science Administration
PUBLIC AGENCY (WSSC) ROADSIDE TREE CARE MAINTENANCE AUTHORIZATION
RTPA No.: 2026-0127 Page: 1 of 1
County: Prince George’s
Authorization No.: 2026-0127-107
WSSC Contract No. BT7171B21
Location: Bowie Western Branch – Patuxent River
WSSC is hereby granted authorization to:
1. **16101 Penn Manor Lane - Protect one private 18” diameter Norway Maple and one public 12” diameter
Norway Maple. Prune limbs and roots as needed.
* Notify property owner at least 48 hours prior to tree removal.
**Note: This permit does not authorize work on private trees. Private trees and trees outside of public road
ROW are not subject to MD Roadside Tree Law. Obtain owner's consent for any private tree removal.
The following ISA standards for ‘open cut’ trenching shall be used to avoid impact to roadside trees. (Please note: Condition #7) If
‘open cut’ trenching is within standard distances noted, responsible person must contact Environmental Group for field inspection and possible amended tree authorization for removal.
Tree Size: Distance from center of tree:
Up to 6” DBH (diameter) Dripline 6 – 9” DBH 5 ft
10 – 14” DBH 10 ft
15 – 19” DBH 12 ft Over 19” DBH 15 ft
Reason for tree care: Large water valve vault replacement on 24” PCCP M. Awad
Number of trees removed: 0
Number of trees planted: 0
Number of trees pruned: 2
Signature of Roadside Tree Care Expert:
John ‘Doug’ Sievers Date: 3/5/2026
John Sievers
CONDITIONS:
1. All work accomplished under this authorization shall comply with the Maryland Department of
Natural Resources Roadside Tree Care Law. (COMAR 08.07.02 or Natural Resources Article 5-401 et seq.).
2. All work including trimming, root pruning, and removals shall be performed by a Licensed Tree
Care Expert under the supervision of a Roadside Tree Care Expert.
3. Tree branch trimming shall be in such a manner so as not to cause damage to other parts of the tree or to other plants or property. Pruning of limbs must be in conformance with the ANSI A300 standards.
4. Roots one inch in diameter or greater shall be cut flush on the tree side of the trench. Excavation to expose roots for pruning must be performed by hand digging.
5. All stockpile fill or excavated material must be either placed on impermeable material or placed outside the dripline of the tree.
6. Tree removal is necessary to eliminate a hazard to public health, public safety, and /or property. If the expressed authorization is for tree care work other than removal and tree removal becomes necessary, then the WSSC or its representative is required to contact the Environmental Group at
301-206-8077 to obtain a revised authorization.
7. WSSC or its representative is required to consider alternative repair/construction methods that avoid open trenching and tree removal as a condition of this authorization.
8. This authorization expires one year from date of issuance.
Soil Boring Logs
0.3 0.5
5.7
6.5
8.5
20.0
3-in Asphalt 3.5-in Concrete Moist, Brown, Soft to Stiff, LEAN CLAY WITH SAND
(CL), Trace Gravel (FILL)
Moist, Gray, Stiff, SILT (ML), (FILL)
Moist, Brown, Medium Stiff, SANDY SILTY CLAY
(CL-ML), (FILL)
Moist, Brown, Loose to Medium Dense, Fine, SILTY
SAND (SM), (CALVERT)
Same, Gray
Same, Gray and Brown
BOTTOM OF HOLE (BOH)
Coordinates and surface elevation of as-drilled borings were estimated from Google Earth, converted to Maryland State Plane Coordinate System and reflected above
1-2-2-5
2-5-5-4
3-6-7-8
4-3-3-4
2-3-6-8
2-3-4
6-4-8
42%
83%
83%
75%
87%
75%
58%
17.2
20.7
NP
NP
0.5- 2.5
2.5- 4.5
4.5- 6.5
6.5- 8.5
8.5- 10.5
13.5- 15.0
18.5- 20.0
121.75 121.46
116.29
115.46
113.46
102.00
S-1
S-2
S-3
S-4
S-5
S-6
S-7
Rig Type Rig No.
Drive Hammer Casing Auger Size Size of Core Size of Bit OD Hammer Energy Ratio Auger Depth
WATER TABLE CAVE-IN TABLE
Elev (ft) Time
(hours)
6/3/22 0.25
6/3/22
DMY/H. GuzmanDMY/A. Melorie
17.0 105.0
LB
IN
IN
IN
FT
Truck CME 45c
3.25
Date
Inspector
Depth Below Surface Depth Below Surface
0 6/3/22
Driller
106.0 0.25
DMY/A. Melorie
6/3/22
6/3/22
Date Started Date Completed
Logged by
Depth (ft)Elev (ft) DateTime
(hours)Depth (ft)
16.0
2of
NMC (%)
Sheet 1 of
REC (%)
M A
TL
Northing
Boring
SPT- Standard Penetration Test
1390134 450622
T-206, T-207
BT7171A-B21
BT7171B21 SB-1
Contract No.
Consultant
REC - RecoveryPI - Plasticity Index LL - Liquid Limit
Legend: NMC - Natural Moisture Content RQD - Rock Quality Designation Elev - Elevation
MATL- Material Graphics Geotech - Geotechnical OD - Outside Diameter
BLOWS/
RQD
SAMPLE
NO.
Easting
REMARKSSAMPLE
DEPTH LL (%)
SPT SPOON/ROCK CORE
PI (%)
Boring and Sampling Conforms to ASTM/AASHTO:
LAB. INDEX TESTSDEPTH
IN
FEET
MATERIAL DESCRIPTION
ELEV.
IN
FEET
TSG/GEO/01
8-31-2015
JMT
Boring No. Ground Surface Elevation
WASHINGTON SUBURBAN SANITARY COMMISSION
STANDARD BORING LOG
Project Description WSSC Task 5 Woodyard Rd & Penn Manor Ln Large Valve Vault
Geotech Consultant/Contractor DMY EC
Station , ' 122.0 ft
W
SS
C S
TA
N
D
AR
D B
O R
IN
G
L O
G [L
ET
TE
R S
IZ
E]
W
SS
C
_T
EM
PL
AT
E.
G
D T
/ 0 3.
4.
D R
AF
T
G
IN
T
LO
G .G
PJ
7/ 5/
DRY
Summary of Pavement Cores
PROJECT NAME: WSSC Task 5 Woodyard Rd & Penn Manor Ln Large Valve Vault Replacement
PROJECT NO.: 03.05394.01
LOCATION: PG County, MD
CLIENT: JMT
PAVEMENT CORE PHOTOGRAPH LOG
Top Top
Bottom Bottom
BT7171B21 PC-1
16101 Penn Manor Ln, Bowie, MD
Asphalt Concrete = 3.0 inches
Portland Cement Concrete = 3.5 inches
Cement-Treated Aggregate = NA inches
Soil Cement = NA inches
Open-Graded Drainage Layer = NA inches
Aggregate Base = NA inches
Soil Cement = NA inches
B T
B P
C -1
Trench Detail
SPECIAL TRENCH DETAIL FOR PAVED AREAS
AutoCAD SHX Text
TRENCH WIDTH PER WSSC STANDARD DETAILS
AutoCAD SHX Text
BITUMINOUS CONCRETE SURFACE COURSE
AutoCAD SHX Text
HOT MIX ASPHALT BASE (HMA)
AutoCAD SHX Text
PAVEMENT RESTORATION LIMITS SEE NOTE 2 FOR REQUIREMENTS
AutoCAD SHX Text
FINAL MILL AND OVERLAY (TO BE DONE BY OTHERS)
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
UNDISTURBED EARTH
AutoCAD SHX Text NOTES: 1. FOLLOW WSSC STANDARD DETAILS LISTED BELOW AND WSSC SPECIFICATION SECTION 02315, EARTHWORK FOR FOLLOW WSSC STANDARD DETAILS LISTED BELOW AND WSSC SPECIFICATION SECTION 02315, EARTHWORK FOR PIPELINE CONSTRUCTION FOR BACKFILL MATERIAL, COMPACTION, AND COMPACTION TEST REQUIREMENTS. M/8.0 - RIGID PIPE GRAVITY RCP SEWERS M/8.1a - FLEXIBLE PIPE (DUCTILE IRON 24-INCH AND SMALLER AND PVC AWWA C900/905) M/8.1b - FLEXIBLE PIPE (DUCTILE IRON 30-INCH AND LARGER) AND OPEN-CUT CASING PIPES M/8.1c - FLEXIBLE PIPE (GRAVITY PVC SEWER SDR 35) 2. FOLLOW JURISDICTIONAL REQUIREMENTS FOR PAVEMENT RESTORATION: FOLLOW JURISDICTIONAL REQUIREMENTS FOR PAVEMENT RESTORATION: A. PRINCE GEORGE'S COUNTY - STD. DTL. STD. 300.18. PRINCE GEORGE'S COUNTY - STD. DTL. STD. 300.18. B. MONTGOMERY COUNTY - STD. DTL. MC-801.02. MONTGOMERY COUNTY - STD. DTL. MC-801.02. C. STATE HIGHWAY ADMINISTRATION - STD. DTL. MD 578.01. STATE HIGHWAY ADMINISTRATION - STD. DTL. MD 578.01. D. WHERE NO JURISDICTIONAL REQUIREMENTS USE WSSC STD. DTL. M/5.2.WHERE NO JURISDICTIONAL REQUIREMENTS USE WSSC STD. DTL. M/5.2.
AutoCAD SHX Text
EXISTING PAVEMENT
AutoCAD SHX Text
PIPE
Valve Card Records
DCammarata Text Box V073
VALVE LOCATION CARD
LOCALITY:
COUNTY:
OLD VALVE CARD
NUMBER:
TIES:
NORTHING & EASTING COORDINATES:
N:
E:
N:
E:
N:
E:
N:
E:
N:
E:
N:
E:
DATE:
DRAWN: CHECKED:
REVISION FOR:
200' SHEET
NUMBER:
CONTRACT
NUMBER:
S
N
EW
THIS VALVE CARD
WAS PREPARED
USING MAPPING
GRADE GPS
DATA UNLESS
OTHERWISE NOTED
CITY OF BOWIE
P 24795
V74
LP 42'
SDMH 43'
028U 36'
07.31.2017
G.SCHULTE
202NE14
BR3680B03
V74
450675
1392341
24"W (662539C)
8"W 8"S (662539C
028U
8"S (662539C)
8"S (662539C) 24"W (662539C)
V74
LP
SDMH
PARKINGTON
LANE
PARKINGTON
LANE
16103
PENN MANOR
LANE
16105
PENN MANOR
LANE
16101
PENN MANOR
LANE
PENN MANOR LN.
PA
R
K
IN
G
TO
N
LN
DCammarata
V074
66253q-s G A 15 Da5-24 t -q -O(" -WFTLrs
TYPE oF va|.v' arutz^6i
MANUFAGTURER
MAI NTENANCE & OPERATI ONS DEPARTMENT
ttATER MAlil UilE ltlSPECTl0lrl SHEET l)eeJ lv€t'' i;&'l$ /brr '1 t reW?daHT Nc>
Daelr'^r
MAIN
VALVE "r=., ofu 14
BY.PASS
VALVE slzet $
N-TER.
* OF TURNS:
GENERAL REMARK9
3&' caa! rn. w
SKETCH
\*+,h s*''
Et4
Porl gcha k tE tuoua!* ta Jo\tr/in - t5'6
HLv 1
H Ltl2
1o eolcl"6osPt' t5'8
So eetrl $asrr 'e6'?
so3-4o lt/ezl FRoNT
DCammarata
V050
V077
V075
VALVE LOCATION CARD
LOCALITY:
COUNTY:
OLD VALVE CARD
NUMBER:
TIES:
NORTHING & EASTING COORDINATES:
N:
E:
N:
E:
N:
E:
N:
E:
N:
E:
N:
E:
DATE:
DRAWN: CHECKED:
REVISION FOR:
200' SHEET
NUMBER:
CONTRACT
NUMBER:
S
N
EW
THIS VALVE CARD
WAS PREPARED
USING MAPPING
GRADE GPS
DATA UNLESS
OTHERWISE NOTED
CITY OF BOWIE
P 24791
12377
V78
F040 30'
040M 29'
LP 57'
07.31.2017
G.SCHULTE
202NE14
BR3680B03
V78
451290
1390965
8"W
F040
V78
LP
040M
6"S (662539D)
6"S (662539D)
24"W (662539D)
24"W (662539D)
PENNINGTON
LANE
PORT ECHO
LANE
PORT ECHO
LANE
PORT ECHO
LANE
PORT ECHO
LANE
PORT ECHO LANE
PEN
N
IN
G
TO
N
LN
DCammarata
V078
V076
C/,N-T: NO,
MAI NTENANCE & OPERATIONS DEPARTMENT
WATER MAIiI tlft|E ITISPECTIOTU SHEET lf4.r" ,* r^J'Fa@
WORK ORDER #
43 8 -?-/
MANUFACTURER
MAIN
VALVE
NAME PLATE DATA
stze'<?41i'
BY.PASS
VALVE
paie an/ ,to. /3I WtNrEg ptp&E SKETCH zo2 Nsl/+ ao"v*Q,r-aio s)
{?cf c-o
9-
=d I t"\ l1aLL RJ.
ptq
Wht | *o F,tl, 4o u&,,- I
FtI 1"o valn" 2-t U -l.o V. o.L,-rlaA,a Z - 86'8
- 57.r _ lj.l"+
g. +
903-4o lr/82l.FRoNT
DCammarata
V096 to.
. CON-T, N
24?5
MAIN
VALVE SIZE:
MAI NTENANCE & OPERATIONS DEPARTMENT
WATER MAIiI LIttIE IIISPECTIOIII SHEET
TYPE OF VALVE
rew'n
BY.PASS
VALVE SIZE:
NAME PLATE DATA
ea.e/rc. 4?5o Wr N-rE€ RtDag
SKETCH ZOZNEI+
ftm Aatr'. lee', UaloL h ,^o"lr,L - 17,6
Ua!-,* 1o Ftl - 2 l.Z U al*e-fo U,O ,L , - | 1, 3
Ua!* lv shrc*{' b,*f frs/ * 3?'*
MANUFACTURER
9o3-ao ll/82t FRoNT
DCammarata
V099
V097
Test Pit Results
JMT Test Hole Summary
JMT Project # 20-02567-005
Large Meter Vault Replacements
T.H. # Northing Easting Utility Depth Top Elev. Date Dug
TP-5
TP-6
All depths are to top of pipe or structure unless the utility is a duct or other rectangular structure -then the depth shown is to the bottom.
450586.7294 1390066.7062 24" PCCP Water 4.65' 117.00' 6/15/22
450641.8566 1390159.9816 24" PCCP Water 4.44' 119.21' " "
TEST HOLE DATA FORM Johnson, Mirmiran Thompson
40 Wight Ave.
Hunt Valley, Maryland 21030
(410) 329-3100
PROJECT INFORMATION
Test Hole # 5 Date Dug - 6/15/22 JMT Project # 20-02567-005
Customer Project # BT717B21 Plan Scale - 1" = 10'
Jurisdiction - Prince George's Co. Plan Sheet #
Location - North side of Penn Manor La. approx. 50' east of Pinecroft La.
Specific Location - N 450586.7294 E 1390066.7062
Type / Amount of Pavement - 5" Asp. over 5" Conc.
Anticipated Size, Type, Material - Unk. Size / Mat. Water
Form Prepared by - Chuck Turner Crew Chief - Jim Matthews
Survey Marker Set by JMT
Mag Nail Hub & Tack X-Cut 8" Nail or Other
At Ex. Grade of Asphalt road
Bench Mark used - R&C set for TRAV JMT 1 Elev. = 121.23'
Cross Section View ( Not to Scale )
Size / Material / Type of Utility
24" PCCP Water 121.65 Ex. Grade Elevation
** Portion of Utility Exposed -
Full Partial 117.00 Elev. Top Utility / Structure
Other, See Remarks Top Actual Field Measurement - 4.65'
Utility Owner - WSSC Elev. Bot. Utility / Structure
Bot. Actual Field Measurement -
Horizontal View ( Not to Scale ) N
Remarks - 1) MAG NAIL W/ BLUE FLAGGING SET FOR ELEVATION REFERENCE & CENTERLINE OF UTILITY.
** PIPE SIZE SHOWN IS FROM UTILITY RECORDS - THE OUTSIDE DIAMETER WILL BE GREATER
BT7171B21
TEST HOLE DATA FORM Johnson, Mirmiran Thompson
40 Wight Ave.
Hunt Valley, Maryland 21030
(410) 329-3100
PROJECT INFORMATION
Test Hole # 6 Date Dug - 6/15/22 JMT Project # 20-02567-005
Customer Project # BT717B21 Plan Scale - 1" = 10'
Jurisdiction - Prince George's Co. Plan Sheet #
Location - North side of Penn Manor La. approx. 90' west of Parkington La.
Specific Location - N 450641.8566 E 1390159.9816
Type / Amount of Pavement - 5" Asp. over 5" Conc.
Anticipated Size, Type, Material - Unk. Size / Mat. Water
Form Prepared by - Chuck Turner Crew Chief - Jim Matthews
Survey Marker Set by JMT
Mag Nail Hub & Tack X-Cut 8" Nail or Other
At Ex. Grade of Asphalt road
Bench Mark used - R&C set for TRAV JMT 1 Elev. = 121.23'
Cross Section View ( Not to Scale )
Size / Material / Type of Utility
24" PCCP Water 123.65 Ex. Grade Elevation
** Portion of Utility Exposed -
Full Partial 119.21 Elev. Top Utility / Structure
Other, See Remarks Top Actual Field Measurement - 4.44'
Utility Owner - WSSC Elev. Bot. Utility / Structure
Bot. Actual Field Measurement -
Horizontal View ( Not to Scale ) N
Remarks - 1) MAG NAIL W/ BLUE FLAGGING SET FOR ELEVATION REFERENCE & CENTERLINE OF UTILITY.
** PIPE SIZE SHOWN IS FROM UTILITY RECORDS - THE OUTSIDE DIAMETER WILL BE GREATER
BT7171B21
| 04e Trench Detail.pdf |
| Sheets and Views |
| Layout1 |
| 04b Permits.pdf |
| Soil Report.pdf |
| Cover |
| Preface |
| Contents |
| How Soil Surveys Are Made |
| Soil Map |
| Soil Map |
| Legend |
| Map Unit Legend |
| Map Unit Descriptions |
| Montgomery County, Maryland |
| 5B—Glenville silt loam, 3 to 8 percent slopes |
| 6A—Baile silt loam, 0 to 3 percent slopes |
| 9C—Linganore-Hyattstown channery silt loams, 8 to 15 percent slopes |
| 16B—Brinklow-Blocktown channery silt loams, 3 to 8 percent slopes |
| 16C—Brinklow-Blocktown channery silt loams, 8 to 15 percent slopes |
| 109D—Hyattstown channery silt loam, 15 to 25 percent slopes, very rocky |
| 116E—Blocktown channery silt loam, 25 to 45 percent slopes, very rocky |
| References |
| Glossary |
File details come from the government source that posted it. Updated .