Attachment8_BICR_Gaston_Motel_100__Draft_Schematic_Design_Floor_Plans.pdf

PDF 2 MB Posted

Attached to
HAFC BICR HISTORIC FURNISHINGS REPORT
Solicitation number
140P2124R0038
Issued by

About this file

This document contains the draft schematic design floor plans for the rehabilitation of the interior of the A.G. Gaston Motel as part of a federal contract opportunity.

The plans depict the proposed work for the basement, first, and second floors, including details such as the reconfiguration of office and exhibit spaces, restoration of historically significant rooms like the "War Room Suite", reconstruction of the exterior walkway, and various building repairs and upgrades. Key scope items include installing new columns and beams, repairing damaged concrete and CMU walls, adding insulation and drywall, and replacing doors to meet ABA compliance. The plans also include building elevations and sections showing the extent of the proposed work. This document is intended to support the HAFC BICR HISTORIC FURNISHINGS REPORT solicitation issued by the Department of the Interior National Park Service.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

REF

BB

1 2 3 4 5 6 7 8 9 10 11 12

A11

A

C

143 SF

OFFICE

143 SF

OFFICE

109 112 SF

OFFICE

112 SF

OFFICE

82 SF

NPS TLT /

SHOWER

107 SF

BLDG

SERVICE

939 SF

NPS OPEN

OFFICE

168 SF

NPS OFFICE

260 SF

CIRCULATION

526 SF

LOBBY /

RECEPTION

278 SF

CONFERENCE

A8 1

A8

A82

A8

A10

A10

A10

A10

A10

A9

12.19.29.18.17.16.15.14.13.12.11.1

1.2

1.2

A.1

A.1

A11

194 SF

NPS BREAK

158 SF

WOMEN

36 SF

BOOKSTORE

STOR.

49 SF

RESTRM

10 SF

STOR.

153 SF

MEN

BLDG

SERVICE

CHASE

103A

14' - 6"

A.2

242 SF

ELEVATOR

LOBBY

STAIR

S101

A11

101A

104105

103A

107108

110 109

101B

A13

JAN.

SINK

EXISTING WALL

NEW WALL

WALL LEGEND

11 12 13

A10

A10

A10

A10

12.1

12.1

A.1A.1

504 SF

BUILDING

SERVICE

A.2A.2

A11

36" X 36" VENT IN

BRICK BETWEEN

STAIR STRINGERS:

1/2" WIRE MESH IN

3/4" WIDE STL FRAME

EXISTING COLUMN GRID

NEW COLUMN GRID

COLUMN GRID LEGEND

SHEET

1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architecture

DATE:

TECH. REVIEW:

PKG.

NO.

OF04/21/23

A5Contact: Hank Houser

LEVEL 1 PLAN - PROPOSED

WORK

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

HWA

LEVEL 1 - FLOOR PLAN - PROPOSED WORK2

BASEMENT LEVEL - PROPOSED WORK1

KEYNOTES - PROPOSED WORK

1 Construct new access stair to basement to match original materials and configuration. Steel stair with concrete treads. Provide metal handrails to match original configuration.

2 Patch and repair concrete foundation wall where damaged from 1963 bomb blast.

3 Remove and replace steel bar joists that are damaged from 1963 bomb blast. See structural report.

4 Repair damaged CMU throughout. Building sections for extents and locations.

Refer to and verify with structural report.

5 Repair concrete slab. See structural report.

6 Block/seal off unused louver openings below windows throughout. Repair/replace damaged studs below windows typ.

7 Install batt insulation at exterior stud wall cavity and gypsum board at interior typ throughout.

8 Repair/replace wood furring at exterior masonry walls and install rigid insulation and gypsum board typ throughout.

9 Install under-stair protection.

10 Replace doors with ABA compliant door as required. See design options for quantity and locations.

11 Restore/reconstruct Lobby and Reception to reflect historically significant period.

13 Install new columns and beam throughout first floor typ. See structural.

16 Install new HM doors and frames.

0 88 16

SCALE OF FEET

GENERAL NOTES

1. Provide self-leveling light weight topping to improve floor level within each room or area and at transitions between rooms/areas.

Attachment 8

BB

1 2 3 4 5 6 7 8 9 10 11 12

A11

AA

CC

198 SF

RESTORED TYP

GUEST ROOM

207 486 SF

RESTORED WAR

ROOM SUITE

288 SF

NPS

OFFICE/CONF

A8

A82

A8

A10

A10

A10

A10

A10

A10

A10

A9

1,026 SF

EXHIBIT SPACE

362 SF

ELEVATOR

LOBBY

ELEV

12.1

12.19.29.18.17.16.15.14.13.12.11.1

1.2

1.2

A.1

A.1

A11

158 SF

WOMEN

153 SF

MEN

148 SF

BLDG SERVICE

A.2A.2

BLDG

SYSTEMS

CHASE

618 SF

EXHIBIT SPACE

CIRCULATION/

HISTORIC

RESTROOM

209A

STAIR 1

EXTERIOR

WALKWAY

A11

209A

206A

A13

A13

A13

208206B

EXISTING WALL

NEW WALL

WALL LEGEND

EXISTING COLUMN GRID

NEW COLUMN GRID

COLUMN GRID LEGEND

SHEET

1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architecture

DATE:

TECH. REVIEW:

PKG.

NO.

OF04/21/23

A6Contact: Hank Houser

LEVEL 2 PLAN - PROPOSED

WORK

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

HWA

LEVEL 2 - FLOOR PLAN - PROPOSED WORK1

0 88 16

SCALE OF FEET

KEYNOTES - PROPOSED WORK

4 Repair damaged CMU throughout. Building sections for extents and locations. Refer to and verify with structural report.

6 Block/seal off unused louver openings below windows throughout. Repair/replace damaged studs below windows typ.

7 Install batt insulation at exterior stud wall cavity and gypsum board at interior typ throughout.

8 Repair/replace wood furring at exterior masonry walls and install rigid insulation and gypsum board typ throughout.

12 Restore/reconstruct War Room suite, including restroom, to reflect historically significant period.

17 Reconstruct exterior walkway wall at war room to match original configuration and reinstall salvaged window and louver. Provide wood studs, sheathing, weather barrier, and stained wood siding to match adjacent restored wall.

21 Pedestrian traffic topping at newly re-exposed exterior walkway. Turn up adjacent walls 8"

22 Install furring and stained wood siding at newly re-exposed masonry wall.

GENERAL NOTES

1. Provide self-leveling light weight topping to improve floor level within each room or area and at transitions between rooms/areas.

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

B AC

A10

A10

A.1A.2

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

B C

BASEMENT

BEYOND

PORTE

COCHERE

A10

A10

A.1 A.2

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

1 2 3 4 5 6 7 8 9 10 11 12 13

LINE OF BASEMENT

BEYOND

AREA OF 1963 BOMB BLAST.

EXIST. DOOR INSTALLED

BEHIND BRICK FACADE

A10

A10

A10

12.19.29.18.17.16.15.14.13.12.11.11.2

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

12345678910111213

BASEMENT BEYOND

LOUVERS FROM PREVIOUSLY

INSTALLED PTAC UNITS TYP.

A10

A10

A10

12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2

SHEET

1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architecture

DATE:

TECH. REVIEW:

PKG.

NO.

OF04/21/23

A8Contact: Hank Houser

BUILDING ELEVATIONS -

PROPOSED WORK

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

HWA

ELEVATION - NORTH1 ELEVATION - SOUTH2

ELEVATION - WEST3

ELEVATION - EAST4

0 88 16

SCALE OF FEET

KEYNOTES - PROPOSED WORK

1. Install sheet metal liner at recess in brick wall at downspout locations; seal edges.

2. Patch and repair hole in brick wall.

3. Remove abandoned metal duct and patch existing wall at planter.

4. Repair/refinish wood siding at modified door swing.

4 4

2 3

LEVEL 2

9' - 4"

ROOF

18' - 8"

678910111213

A10

A10

A10

12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2

SHEET

1819 Peachtree Road, NE

Suite 102

Atlanta, GA 30309

404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architecture

DATE:

TECH. REVIEW:

PKG.

NO.

OF04/21/23

A9Contact: Hank Houser

BUILDING ELEVATIONS -

PROPOSED WORK

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

HWA

ELEVATION - EAST - AT BALCONY1

0 88 16

SCALE OF FEET

LEVEL 2

9' - 4"

ROOF

18' - 8"

BA5

A10

A10

A.1

A.2

STEEL BEAM

SEE STRUCT.

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

B C

A10

PORTE

COCHERE

A10

A.1 A.2

STEEL BEAM

SEE STRUCT.

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

12345678910111213

APPROXIMATE AREA OF

CONCRETE REPAIR AFTER

1963 BOMB BLAST DAMAGE

A10

A10

A10

12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

1 2 3 4 5 6 7 8 9 10 11 12 13

A10

A10

A10

12.19.29.18.17.16.15.14.13.12.11.11.2

STEEL BEAM

SEE STRUCT.

BASEMENT

-9' - 4"

LEVEL 1

0"

LEVEL 2

9' - 4"

ROOF

18' - 8"

BC 5

A10

A10

A.1A.2

SHEET

1819 Peachtree Road, NE

Suite 102

Atlanta, GA 30309

404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architecture

DATE:

TECH. REVIEW:

PKG.

NO.

OF04/21/23

A10Contact: Hank Houser

BUILDING SECTIONS -

PROPOSED WORK

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

HWA

BUILDING SECTION - TRANSVERSE - NORTH1

BUILDING SECTION - TRANSVERSE - NORTH @

LOBBY & WAR ROOM2

BUILDING SECTION - LONGITUDINAL - WEST5

BUILDING SECTION - LONGITUDINAL - EAST4

BUILDING SECTION - TRANSVERSE - SOUTH @

STAIR3

0 88 16

SCALE OF FEET

Cabinet doors with vertical wood siding continuing from adjacent wall surface.

Vertical wood siding on wall behind counter.

New wood interior 36" door w/steel frame.

New wood interior 36" door w/steel frame .

Will require new 36" door.

Low brick wall with wood planter on top.

Ceiling smooth drywall with square LED lights matching the original size and configuration.

Vertical wood siding on wall and above the reception counter.

Retain remaining original siding.

Plywood reception counter with Formica top.

Exposed brick walls below wood storefront Recommend retaining original door size and keeping it active.

Furniture shown for context only.

Square floor tile, 9x9, matching original color scheme.

Flush wood closet door.

Furniture shown for context only.

Privacy curtain.

Extend wall to original location.

New 36" flush wood door.

Carpet floor finish.

Wall and ceiling finish to be smooth gypsum board.

Historic Bathroom configuration

Tile floor, wainscot, and shower.

9x9 floor tile.

Wall and ceiling finish to be smooth gypsum board.

Furniture shown for context only.

Opportunity to add a cased opening or door at this location. While not historically there it could permit access through the room as an exhibit.

Opportunity to add a cased opening or door at this location which is historically appropriate for those rooms that had an adjoining door.

Closet shelf and garment rod.

Entry through the historic restroom will require new 36" wide cased opening or door.

Entry through the historic bathroom will require a new 36" wide cased opening or door from the exhibit space.

Preserve remaining historic shower and tile.

4 8 FT0

Potential to uncover the original tile beneath later layer of tile.

0 88 16

SCALE OF FEET

SHEET

1819 Peachtree Road, NE

Suite 102

Atlanta, GA 30309

404.633.4264 houserwalker.com

TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM

Houser Walker Architects

DATE:

TECH. REVIEW:

PKG.

NO.

OF

A13Contact: Hank Houser

ENLARGED PLANS - PROPOSED

REHABILITATE INTERIOR OF A.G. GASTON MOTEL

LAS

WORK

4/21/23

4 8 FT01

LOBBY

HISTORIC WAR ROOM PLAN

STANDARD ROOM

4 8 FT0

4 8 FT0

WAR RM BATH RM ENTRY OPTION

File details come from the government source that posted it. Updated .