Attachment8_BICR_Gaston_Motel_100__Draft_Schematic_Design_Floor_Plans.pdf
PDF 2 MB Posted
- Attached to
- HAFC BICR HISTORIC FURNISHINGS REPORT
- Solicitation number
- 140P2124R0038
About this file
This document contains the draft schematic design floor plans for the rehabilitation of the interior of the A.G. Gaston Motel as part of a federal contract opportunity.
The plans depict the proposed work for the basement, first, and second floors, including details such as the reconfiguration of office and exhibit spaces, restoration of historically significant rooms like the "War Room Suite", reconstruction of the exterior walkway, and various building repairs and upgrades. Key scope items include installing new columns and beams, repairing damaged concrete and CMU walls, adding insulation and drywall, and replacing doors to meet ABA compliance. The plans also include building elevations and sections showing the extent of the proposed work. This document is intended to support the HAFC BICR HISTORIC FURNISHINGS REPORT solicitation issued by the Department of the Interior National Park Service.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
REF
BB
1 2 3 4 5 6 7 8 9 10 11 12
A11
A
C
143 SF
OFFICE
143 SF
OFFICE
109 112 SF
OFFICE
112 SF
OFFICE
82 SF
NPS TLT /
SHOWER
107 SF
BLDG
SERVICE
939 SF
NPS OPEN
OFFICE
168 SF
NPS OFFICE
260 SF
CIRCULATION
526 SF
LOBBY /
RECEPTION
278 SF
CONFERENCE
A8 1
A8
A82
A8
A10
A10
A10
A10
A10
A9
12.19.29.18.17.16.15.14.13.12.11.1
1.2
1.2
A.1
A.1
A11
194 SF
NPS BREAK
158 SF
WOMEN
36 SF
BOOKSTORE
STOR.
49 SF
RESTRM
10 SF
STOR.
153 SF
MEN
BLDG
SERVICE
CHASE
103A
14' - 6"
A.2
242 SF
ELEVATOR
LOBBY
STAIR
S101
A11
101A
104105
103A
107108
110 109
101B
A13
JAN.
SINK
EXISTING WALL
NEW WALL
WALL LEGEND
11 12 13
A10
A10
A10
A10
12.1
12.1
A.1A.1
504 SF
BUILDING
SERVICE
A.2A.2
A11
36" X 36" VENT IN
BRICK BETWEEN
STAIR STRINGERS:
1/2" WIRE MESH IN
3/4" WIDE STL FRAME
EXISTING COLUMN GRID
NEW COLUMN GRID
COLUMN GRID LEGEND
SHEET
1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architecture
DATE:
TECH. REVIEW:
PKG.
NO.
OF04/21/23
A5Contact: Hank Houser
LEVEL 1 PLAN - PROPOSED
WORK
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
HWA
LEVEL 1 - FLOOR PLAN - PROPOSED WORK2
BASEMENT LEVEL - PROPOSED WORK1
KEYNOTES - PROPOSED WORK
1 Construct new access stair to basement to match original materials and configuration. Steel stair with concrete treads. Provide metal handrails to match original configuration.
2 Patch and repair concrete foundation wall where damaged from 1963 bomb blast.
3 Remove and replace steel bar joists that are damaged from 1963 bomb blast. See structural report.
4 Repair damaged CMU throughout. Building sections for extents and locations.
Refer to and verify with structural report.
5 Repair concrete slab. See structural report.
6 Block/seal off unused louver openings below windows throughout. Repair/replace damaged studs below windows typ.
7 Install batt insulation at exterior stud wall cavity and gypsum board at interior typ throughout.
8 Repair/replace wood furring at exterior masonry walls and install rigid insulation and gypsum board typ throughout.
9 Install under-stair protection.
10 Replace doors with ABA compliant door as required. See design options for quantity and locations.
11 Restore/reconstruct Lobby and Reception to reflect historically significant period.
13 Install new columns and beam throughout first floor typ. See structural.
16 Install new HM doors and frames.
0 88 16
SCALE OF FEET
GENERAL NOTES
1. Provide self-leveling light weight topping to improve floor level within each room or area and at transitions between rooms/areas.
Attachment 8
BB
1 2 3 4 5 6 7 8 9 10 11 12
A11
AA
CC
198 SF
RESTORED TYP
GUEST ROOM
207 486 SF
RESTORED WAR
ROOM SUITE
288 SF
NPS
OFFICE/CONF
A8
A82
A8
A10
A10
A10
A10
A10
A10
A10
A9
1,026 SF
EXHIBIT SPACE
362 SF
ELEVATOR
LOBBY
ELEV
12.1
12.19.29.18.17.16.15.14.13.12.11.1
1.2
1.2
A.1
A.1
A11
158 SF
WOMEN
153 SF
MEN
148 SF
BLDG SERVICE
A.2A.2
BLDG
SYSTEMS
CHASE
618 SF
EXHIBIT SPACE
CIRCULATION/
HISTORIC
RESTROOM
209A
STAIR 1
EXTERIOR
WALKWAY
A11
209A
206A
A13
A13
A13
208206B
EXISTING WALL
NEW WALL
WALL LEGEND
EXISTING COLUMN GRID
NEW COLUMN GRID
COLUMN GRID LEGEND
SHEET
1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architecture
DATE:
TECH. REVIEW:
PKG.
NO.
OF04/21/23
A6Contact: Hank Houser
LEVEL 2 PLAN - PROPOSED
WORK
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
HWA
LEVEL 2 - FLOOR PLAN - PROPOSED WORK1
0 88 16
SCALE OF FEET
KEYNOTES - PROPOSED WORK
4 Repair damaged CMU throughout. Building sections for extents and locations. Refer to and verify with structural report.
6 Block/seal off unused louver openings below windows throughout. Repair/replace damaged studs below windows typ.
7 Install batt insulation at exterior stud wall cavity and gypsum board at interior typ throughout.
8 Repair/replace wood furring at exterior masonry walls and install rigid insulation and gypsum board typ throughout.
12 Restore/reconstruct War Room suite, including restroom, to reflect historically significant period.
17 Reconstruct exterior walkway wall at war room to match original configuration and reinstall salvaged window and louver. Provide wood studs, sheathing, weather barrier, and stained wood siding to match adjacent restored wall.
21 Pedestrian traffic topping at newly re-exposed exterior walkway. Turn up adjacent walls 8"
22 Install furring and stained wood siding at newly re-exposed masonry wall.
GENERAL NOTES
1. Provide self-leveling light weight topping to improve floor level within each room or area and at transitions between rooms/areas.
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
B AC
A10
A10
A.1A.2
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
B C
BASEMENT
BEYOND
PORTE
COCHERE
A10
A10
A.1 A.2
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
1 2 3 4 5 6 7 8 9 10 11 12 13
LINE OF BASEMENT
BEYOND
AREA OF 1963 BOMB BLAST.
EXIST. DOOR INSTALLED
BEHIND BRICK FACADE
A10
A10
A10
12.19.29.18.17.16.15.14.13.12.11.11.2
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
12345678910111213
BASEMENT BEYOND
LOUVERS FROM PREVIOUSLY
INSTALLED PTAC UNITS TYP.
A10
A10
A10
12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2
SHEET
1819 Peachtree Road, NE Suite 102 Atlanta, GA 30309 404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architecture
DATE:
TECH. REVIEW:
PKG.
NO.
OF04/21/23
A8Contact: Hank Houser
BUILDING ELEVATIONS -
PROPOSED WORK
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
HWA
ELEVATION - NORTH1 ELEVATION - SOUTH2
ELEVATION - WEST3
ELEVATION - EAST4
0 88 16
SCALE OF FEET
KEYNOTES - PROPOSED WORK
1. Install sheet metal liner at recess in brick wall at downspout locations; seal edges.
2. Patch and repair hole in brick wall.
3. Remove abandoned metal duct and patch existing wall at planter.
4. Repair/refinish wood siding at modified door swing.
4 4
2 3
LEVEL 2
9' - 4"
ROOF
18' - 8"
678910111213
A10
A10
A10
12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2
SHEET
1819 Peachtree Road, NE
Suite 102
Atlanta, GA 30309
404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architecture
DATE:
TECH. REVIEW:
PKG.
NO.
OF04/21/23
A9Contact: Hank Houser
BUILDING ELEVATIONS -
PROPOSED WORK
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
HWA
ELEVATION - EAST - AT BALCONY1
0 88 16
SCALE OF FEET
LEVEL 2
9' - 4"
ROOF
18' - 8"
BA5
A10
A10
A.1
A.2
STEEL BEAM
SEE STRUCT.
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
B C
A10
PORTE
COCHERE
A10
A.1 A.2
STEEL BEAM
SEE STRUCT.
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
12345678910111213
APPROXIMATE AREA OF
CONCRETE REPAIR AFTER
1963 BOMB BLAST DAMAGE
A10
A10
A10
12.1 9.2 9.1 8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1 1.2
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
1 2 3 4 5 6 7 8 9 10 11 12 13
A10
A10
A10
12.19.29.18.17.16.15.14.13.12.11.11.2
STEEL BEAM
SEE STRUCT.
BASEMENT
-9' - 4"
LEVEL 1
0"
LEVEL 2
9' - 4"
ROOF
18' - 8"
BC 5
A10
A10
A.1A.2
SHEET
1819 Peachtree Road, NE
Suite 102
Atlanta, GA 30309
404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architecture
DATE:
TECH. REVIEW:
PKG.
NO.
OF04/21/23
A10Contact: Hank Houser
BUILDING SECTIONS -
PROPOSED WORK
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
HWA
BUILDING SECTION - TRANSVERSE - NORTH1
BUILDING SECTION - TRANSVERSE - NORTH @
LOBBY & WAR ROOM2
BUILDING SECTION - LONGITUDINAL - WEST5
BUILDING SECTION - LONGITUDINAL - EAST4
BUILDING SECTION - TRANSVERSE - SOUTH @
STAIR3
0 88 16
SCALE OF FEET
Cabinet doors with vertical wood siding continuing from adjacent wall surface.
Vertical wood siding on wall behind counter.
New wood interior 36" door w/steel frame.
New wood interior 36" door w/steel frame .
Will require new 36" door.
Low brick wall with wood planter on top.
Ceiling smooth drywall with square LED lights matching the original size and configuration.
Vertical wood siding on wall and above the reception counter.
Retain remaining original siding.
Plywood reception counter with Formica top.
Exposed brick walls below wood storefront Recommend retaining original door size and keeping it active.
Furniture shown for context only.
Square floor tile, 9x9, matching original color scheme.
Flush wood closet door.
Furniture shown for context only.
Privacy curtain.
Extend wall to original location.
New 36" flush wood door.
Carpet floor finish.
Wall and ceiling finish to be smooth gypsum board.
Historic Bathroom configuration
Tile floor, wainscot, and shower.
9x9 floor tile.
Wall and ceiling finish to be smooth gypsum board.
Furniture shown for context only.
Opportunity to add a cased opening or door at this location. While not historically there it could permit access through the room as an exhibit.
Opportunity to add a cased opening or door at this location which is historically appropriate for those rooms that had an adjoining door.
Closet shelf and garment rod.
Entry through the historic restroom will require new 36" wide cased opening or door.
Entry through the historic bathroom will require a new 36" wide cased opening or door from the exhibit space.
Preserve remaining historic shower and tile.
4 8 FT0
Potential to uncover the original tile beneath later layer of tile.
0 88 16
SCALE OF FEET
SHEET
1819 Peachtree Road, NE
Suite 102
Atlanta, GA 30309
404.633.4264 houserwalker.com
TITLE OF SHEET DRAWING NO.SUB SHEET NO.DESIGNED:A/E FIRM
Houser Walker Architects
DATE:
TECH. REVIEW:
PKG.
NO.
OF
A13Contact: Hank Houser
ENLARGED PLANS - PROPOSED
REHABILITATE INTERIOR OF A.G. GASTON MOTEL
LAS
WORK
4/21/23
4 8 FT01
LOBBY
HISTORIC WAR ROOM PLAN
STANDARD ROOM
4 8 FT0
4 8 FT0
WAR RM BATH RM ENTRY OPTION