This document is a set of building floor plans depicting network infrastructure installation requirements across multiple buildings. The plans show the locations of networking equipment and access points to be installed or modified across four floors of Building 1, two floors of Building 2, and Building 8.
Building 1 requirements include: First floor installation of two consoles, four switches, one firewall, one server, and multiple access points (AP 1-10) with a TR room; second floor removal of one access point and installation of CAT6A cabling for a router on the third floor; third floor installation of one new antenna, one new router, and CAT6A cabling; fourth floor installation of one switch and multiple access points (AP 4-10). Building 2 requirements span two floors with installation of one repeater, one router, CAT6A cabling, and access points (AP 1-2). Building 8 requirements include installation of one rack, one router, one switch, one antenna, CAT6A cabling, and two access points (AP 1-2). All cabling is specified as CAT6A category cable. The plans use color coding and symbols to indicate router locations (blue), antenna locations (cross-hatch pattern), access points (magenta circles), and the TR (telecommunications room) on Building 1's first floor (light blue).
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment IV - Contractor EMR Certification Form 610A4-25-226.pdf | ||
| 36C25026B0012 0002 Amendment.pdf | ||
| Attachment VIII - RFI Form-36C25026B0012.pdf | ||
| Attachment IX - Sign-in Sheet.pdf | ||
| Attachment V - Standards Specification.pdf | ||
| 36C25026B0012 0003.pdf | ||
| Attachment VII - Basic Site Map.pdf | ||
| Attachment III - Davis-Bacon.pdf | ||
| Attachment II - Update Patient Wi-Fi - Specifications.pdf | ||
| Attachment I - VHA Directive 1192.pdf | ||
| 36C25026B0012 0001 Amendment-A.pdf | ||
| 36C25026B0012_1.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
UP UP
UP
UPUP UP
UP
UP
UP
UP
UP
UP
UP
186A
192B
193194A
194D
194B
A156K
187A
STAIR 5
192C
180A
176A
173 175A 172 171 170 169A 169 168 167 166
163 162A
STAIR 4
1E-3
1601E-4 158A158157
1G148
1GEL3
1G147
1G146
1G116
1G115 1G1141G1131G1121G1111G1101G1091G1081G1071G1061G1051G104
1GC1
1G117
1GC3
1G1451G1441G1431G142
1G119 1G1181G1201G1211G122
1GC2
1G123
1G124 1G1251G1261G1271G128
1G129
1G154
1G1391G141
1G140
1G1381G1371G1361G135 1G134
1G133 1G132
1GEL1-2
1G130
156155154A154153152
1GC4
148A149
1G102
1GC5
1G103
STAIR 10
1G101C
1G101A
1G100
1G101D
1G101
143141140139138B138A138
134133132
129128127
126A
128A
123D
123 123A 123B 123C
STAIR 2
121G121F
121D
121E
121B121A120A120119
115 114121H
110B
A158A157
A104
A101
A159
109D
109C
A109B
A164
107A
107 106A109A 109 100A
A169
A167
169E
A166A165
A156E
A156F
A156D
A156C
A156B
A156A
A156 A153
A151 A156G
A149
A155
A139
A154
A137
A145 A146A144
A127B
A123
A125
A127A
A132 A134A127
A129
A128
A126
A124A107
A109
A111
A113
A138 A170
A136A135A133A131A115A116
A114
A112
A110
A108
A106
A122
A105 A120
A118A103
A121
A119
A117
A140
A143 A152
A150
A148
A142
A141
A102
A102A
1ST FLOOR
STAIR 3
STAIR 1
STAIR 9
STAIR 6
STAIR 8
AP 7
AP 6
AP 2
AP 4
AP 8
AP 5
AP 3
AP 1
AP 9
AP 10
BUILDING 1 -
TR ROOM
AP # ACCESS POINT
(2) CONSOLES
(4) SWITCHES
(1) FIREWALL
(1) SERVER
AutoCAD SHX Text N
UPUP UP
UP
UP
UP
UP
249A
249B
249C
C204
249D
250A
252 253
255A 255 255B 256
257B
260 258 257A264 263265266
245244243242241
240A
237A
233232
237B
228227226
224B
226A 223B
221A
220 219
219 218A
217 216A
C202
216 215
214A
211 210C
210B
210A
C203
200B 208A
207A 202
201 200
C200
270A
2ND FLOOR
STAIR 5
STAIR 6
AP1
AP2 AP3
AP4
BUILDING 1 -
AP # ACCESS POINT
ACCESS POINT
TO BE REMOVED
(1) SWITCH
CAT6A CABLING
FOR ROUTER
ON 3RD FLOOR
UPUP
UP UP
UP
3306 3-103
3318 3322A 3322B 3326B 3326C
332433203C2 3326A 3-C5
3-112
3-114
3333A 3333B 3333C 3333D
3333E
3333F3333G3333H3333I
3329332733253323332133193317
3C4
3C3
33093305
3311 3309A
3315B3315D
3315C
3315E 3315A
3303A
3FP1
3159A
31593157 3157B
355A
3-3553151
354A353A
31493147
352A 31433141
347A
3-347
3-345A
334A
3-341A
340A
312131193117
3111310931053103
3-335B 3106 3108
3114 3116
3118 3120
3140A
31403128
3146A 3148
3148A 3150
3204A
3210A
3228A
3232 OR
3235A
3232A
3225A
3217B 3217A
3C303
3C300
3RD FLOOR
STAIR 4
STAIR 2 STAIR 3
STAIR 1
STAIR 6
BUILDING 1 -
ANTENNA
(1) NEW ANTENNA
CAT6A CABLING
ROUTER
(1) NEW ROUTER
UPUP UP
4104 4108
4108A4104A
C41014102
4101 4103 4107 4109 4111 4115 4117 4119 4121 4123
4144A 4142
4146A
4147 4147A
C4106
4143A
4141 4155C4105
C4107
4159 4163 4167
41694165 4303
43054301 4311 4315 4317 4321
4332A
C4302
4334A
4334B
C4303
4331 4333A
4347 4349
4350 4351
4353A
4365A
43684364 4364A
4348A
4352A
4346A4326A
4340 4342
C4304 C4305
4324A
4320A
43184316A
C4301
4312A
4310C41084110 C4103 4114A
4116A 4118A
4120A
C4104
4126 4128
4124A 4130A 4130 4150
4150A
4154 4156
4154A 4156A 4160A
4164A
C4109
4172 4174 4176
C4111
C4110
MECH
4TH FLOOR
STAIR 4
STAIR 2 STAIR 3
STAIR 1
AP 1
AP 2
AP 11
AP 5
AP 4
AP 5
AP 9
AP 10 AP 6
AP 7
AP 8
BUILDING 1 -AP # ACCESS POINT
(1) SWITCH
BUILDING 2
UP
UP
UP
UP
LOCKSMITH
105A
PAINT
SHOP
UP
DN
UP
UP
UP
UP
OFFICE
ROOM
BATH
CARP SHOP
HVAC SHOP
STORAGE
TOILET
LOCKER
PIPE SHOP
211A
CARP SHOP
BREAK
ROOM
209 OFFICE
ROOM
OFFICE
ROOM
GARAGE
BLDG 2 FIRST FLOOR PLAN BLDG 2 SECOND FLOOR PLAN
AP 2
AP 1
AP 3
ROUTER
AP # ACCESS POINT
(1) REPEATER
(1) ROUTER
CAT6A CABLING
ANTENNA
DN
UP
DN
VESTIBULE
101 O.I.T.
EXAM
HEIGHT &
WEIGHT
EXAM
PATIENT
RESTROOM
EXAM
OPEN
OFFICE
CONSULT
EXAM
RESTROOM
EXAM
WOMENS
HEALTH
BREAK
ROOM
MED ROOM
CLOSET
SOILED
SUPPLY
CLEAN
SUPPLY
MECHANICAL
WOMENS
MENS
CONSULTEXAMEXAMEXAMEXAM
PATIENT
RESTROOM
EXAMEXAM
RESTROOMRESTROOM
WAITING
134 RECEPTION
WORK
ROOM
HALL
CORRIDOR
C101
CORRIDOR
C102
HEIGHT &
WEIGHT
130H.A.C.
WAITING
OFFICE
CONFERENCE
131 129 127 126 125 124 123
AP 1
AP 2
BUILDING 8
AP # ACCESS POINT
(1) ANTENNA
(1) RACK
(1) ROUTER
(1) SWITCH
ANTENNA
ROUTER
CAT6A CABLING
| Sheets and Views |
| 610A-25-226 Update Patient WiFi-1st WiFi |
| 610A-25-226 Update Patient WiFi-2nd WiFi |
| 610A-25-226 Update Patient WiFi-3rd WiFi |
| 610A-25-226 Update Patient WiFi-4th WiFi |
| 610A-25-226 Update Patient WiFi-5th WiFi |
| 610A-25-226 Update Patient WiFi-B2 WiFi |
| 610A-25-226 Update Patient WiFi-B8 WiFi |
File details come from the government source that posted it. Updated .