Attachment S_Drawings.pdf
PDF 27 MB Posted
- Attached to
- MDOT MVA Waldorf Branch Roof Replacement
- Solicitation number
- BPM038485
- Issued by
- Charles County, Walker Mill CDP, Maryland
About this file
Attachment S_Drawings.pdf contains drawings related to the MDOT MVA Waldorf Branch Roof Replacement project located in Charles County, Maryland and the Walker Mill CDP area. This project consists of replacing the existing low-slope roofing systems on Roof #1 and repairing and installing a new roofing system on Roof #2 for the MDOT MVA Waldorf Branch office location.
The document does not contain information about pricing terms, set asides, incumbents, funding requirements and sources, or other salient details beyond the scope of work and jurisdictions involved.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10200 GRAND CENTRAL AVENUE, SUITE 310, OWINGS MILLS, MD 21117
L o c a l F ile
/9
/2
:0
:1
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
ATTACHMENT S
WALDORF BRANCH ROOF REPLACEMENT
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
DRAWING INDEX
GENERAL
1 G001 COVER SHEET
ARCHITECTURAL
2 A001 GENERAL NOTES, SYMBOLS, LEGENDS & ABBREVIATIONS
3 AD101 ROOF PLAN - DEMOLITION
4 AD102 SITE & DOWNSPOUT DEMOLITION
5 A101 ROOF PLAN - ROOF 1
6 A102 ROOF PLAN - ROOF 2
7 A501 DETAILS
8 A502 DETAILS
MECHANICAL
8 M001 LEGEND, GENERAL NOTES & ABBREVIATIONS
9 MD101 ABOVE CEILING AND ROOF DEMOLITION PLANS
10 M101 ABOVE CEILING AND ROOF PLANS
11 M501 DETAILS AND SCHEDULES
MOTOR VEHICLE ADMINISTRATION
CONTRACT NO. V-WAL-24007C
VICINITY MAP LOCATION MAP
SCALE: NTS SCALE: NTS
BRICK
CONCRETE MASONRY UNITS
ACOUSTICAL CMU
CMIU
STRUCTURAL GLAZED
FACING TILE/ GLAZED CMU
CONCRETE
GYPSUM BOARD / GROUT
BATT INSULATION
RIGID INSULATION
COARSE AGGREGATE /
BALLAST
STEEL
ALUMINUM
FINISH LUMBER
DIMENSIONAL LUMBER
SHIM
PLYWOOD
TILE / ACOUSTIC PANEL
EARTH / SOIL
M888
SIM
101A
ROOM
101A
L-2
A
W1
L1
A101
A101
A101
DETAIL REFERENCE
DRAWING ON WHICH DETAIL APPEARS
DOOR NUMBER REFERENCE
LINTEL TYPE REFERENCE
STRUCTURAL COLUMN REFERENCE
TOILET ACCESSORY REFERENCE
WALL PARTITION REFERENCE
WINDOW TYPE REFERENCE
LOUVER TYPE REFERENCE
ROOM SIGN REFERENCE
SHEET NOTE REFERENCE
DETAIL REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
WALL SECTION REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
BUILDING SECTION REFERENCE
ELEVATION REFERENCE
DRAWING ON WHICH ELEVATION APPEARS
EXTERIOR ELEVATION REFERENCE
CEILING TYPE
HEIGHT OF CEILING ABOVE FLOOR
CEILING SYSTEM REFERENCE
INTERIOR ELEVATION REFERENCE
MAGNETIC NORTH
BUILDING NORTH
NORTH ARROW REFERENCE
ROOM NAME
ROOM NUMBER
ROOM IDENTIFICATION REFERENCE
REVISION REFERENCE
A
DRAWING ON WHICH DETAIL APPEARS
ELEVATION REFERENCE
R1
TYPE A
10'-0"
1. ALL WORK TO CONFORM TO REQUIREMENTS OF THE GOVERNING
BUILDING CODE, OSHA AND ALL OTHER APPLICABLE CODES, RULES,
REGULATIONS, ORDINANCES, ETC. IN THEIR LATEST EDITION. CONFORM
ALL WORK TO REQUIREMENTS OF ALL AUTHORITIES HAVING
JURISDICTION.
2. ALL WORK THAT IS IMPLIED OR REASONABLY INFERRED BY THE
DRAWINGS IS THE RESPONSIBILITY OF THE CONTRACTOR. THE
INCLUSION OF ANY AND ALL WORK BY MENTION, NOTATION, DETAIL,
ITEMIZATION OR IMPLICATION, HOWEVER BRIEF, MEANS THAT THE
CONTRACTOR TO PROVIDE AND INSTALL SAME AT NO ADDITIONAL COST
OR BURDEN TO THE OWNER. ALL WORK PERFORMED TO INCLUDE ALL
APPURTENANCES AND APPARATUS NORMALLY DEEMED TO BE PART OF
A COMPLETE PACKAGE WITHIN THE DEFINITIONS OF ORDINARY
INDUSTRY STANDARDS. ALL TRADES ARE RESPONSIBLE FOR
REVIEWING THE ENTIRE SET OF DRAWINGS THEREBY NOTING AND
INCLUDING THEIR WORK AS APPLICABLE. THE INTENT OF THE DRAWING
SET IS TO RESULT IN A COMPLETE AND FINISHED PROJECT IN ALL
REGARDS AT THE CONCLUSION OF THE WORK. INCLUDE ALL WORK,
WHETHER SHOWN OR NOT, AS MAY BE NECESSARY TO ACCOMPLISH
THE INTENDED RESULT.
3. APPLY AND PAY FOR ALL PERMITS, INSPECTIONS, APPROVALS, ETC.
ARRANGE AND COORDINATE ALL REQUIRED INSPECTIONS AND SECURE
ALL NECESSARY APPROVALS OF THE WORK.
4. BECOME FAMILIAR WITH THE PROJECT THROUGH INSPECTION OF THE
SITE AND REVIEW OF THE DRAWINGS SO AS TO THOROUGHLY
UNDERSTAND THE NATURE AND REQUIREMENTS OF THE WORK. ANY
AND ALL DISCREPANCIES OR OMISSIONS TO BE REPORTED TO THE
OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY
SUCH DISCREPANCY OR OMISSION. ENSURE THAT DISCREPANCIES OR
OMISSIONS ARE REPORTED AND CLARIFICATION OBTAINED PRIOR TO
WORK BEING PERFORMED. ANY AND ALL WORK PROCEEDING
OTHERWISE AND THEN FOUND TO BE INCORRECT OR INCONSISTENT
WITH THE INTENDED RESULT WILL BE REMOVED, REPLACED AND/OR
CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST OR
BURDEN TO THE OWNER. VERIFY ALL DIMENSIONS AND LOCATIONS IN
THE FIELD. COORDINATE ALL WORK WITH CONDITIONS ENCOUNTERED
IN THE FIELD AND MAKE ALL NECESSARY ADJUSTMENTS ACCORDINGLY.
5. CONTRACTOR IS RESPONSIBLE FOR FINAL FIT, FINISH, APPEARANCE AND
PERFORMANCE OF ALL WORK.
6. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE WORK SITE PRIOR TO
THE COMMENCEMENT OF WORK.
7. VERIFY EXISTING CONDITIONS AFFECTING THE WORK PRIOR TO BIDDING
AND ALL ASPECTS OF THE WORK PRIOR TO COMMENCEMENT.
8. APPLY, INSTALL OR UTILIZE ALL MATERIALS IN ACCORDANCE WITH
MANUFACTURER’S PRINTED LITERATURE.
9. ALL WORK TO BE PERFORMED IN A FIRST-CLASS WORKMANLIKE
MANNER, MATCHING AND ALIGNING ALL SURFACES SO AS TO AFFORD A
NEAT FINISHED APPEARANCE. CLEAN ALL SURFACES FREE OF SOIL,
DIRT, REFUSE AND DEBRIS RESULTANT FROM THE WORK. ALL
ADJACENT SURFACES TO BE LEFT AS THEY APPEARED PRIOR TO
COMMENCEMENT OF THE WORK. PROVIDE ADEQUATE PROTECTION OF
ALL ADJACENT AND EXISTING SURFACES TO REMAIN SUFFICIENT TO
ENSURE AGAINST DAMAGE DURING CONSTRUCTION OPERATIONS. AT
CONCLUSION OF THE WORK, ALL FINISHED EXPOSED SURFACES
INCLUDING GLASS, ALUMINUM AND FINISHED HARDWARE TO BE
THOROUGHLY CLEANED TO THE SATISFACTION OF THE OWNER.
10. ALL WORK TO BE PROPERLY AND ADEQUATELY PROTECTED FROM
DAMAGE AT ALL TIMES REGARDLESS OF THE STAGE OF COMPLETION.
TAKE RESPONSIBILITY FOR SAFETY AT ALL TIMES, IN ALL PLACES AND
UNDER ALL CONDITIONS AFFECTING OR AFFECTED BY THE WORK.
ADHERE TO ALL ACCEPTED SAFETY PRACTICES AND PROVIDE ALL
FENCES, BARRICADES, GUARDRAILS, PARTITIONS, ETC. AS MAY BE
NECESSARY IN ORDER TO PROTECT LIFE AND PROPERTY FROM INJURY
OR DAMAGE AND AS MAY BE REQUIRED BY ANY AND ALL AUTHORITIES
HAVING JURISDICTION. REPAIR ANY AND ALL DAMAGE TO THE PREMISES
ARISING FROM OR ASSOCIATED WITH WORK SITE OPERATIONS AND/OR
ACTIVITIES CONNECTED TO THE WORK.
11. LEAVE ALL CHASES, HOLES, OPENINGS, ETC. PLUMB LEVEL, TRUE AND
OF A PROPER SIZE OR CUT SAME INTO EXISTING WORK AS MAY BE
NECESSARY FOR PROPER INSTALLATION OF WORK. CONSULT, CONFER
AND OTHERWISE COORDINATE WITH ANY AND ALL OTHER
CONTRACTORS AND CONCERNED PARTIES REGARDING PROPER
LOCATION, SIZE, PLACEMENT, ALIGNMENT AND ORIENTATION OF SAME.
IN CASE OF ANY FAILURE TO LEAVE OR CUT SUCH OPENINGS OR
OTHERWISE LEAVE SUCH ACCOMMODATIONS IN PROPER PLACE, CUT
THEM AFTERWARDS AT OWN EXPENSE. NO EXCESSIVE CUTTING WILL
BE PERMITTED NOR ANY STRUCTURAL MEMBERS TO BE CUT WITHOUT
THE CONSENT OF THE ARCHITECT.
12. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. ALL LABOR, EQUIPMENT AND
MATERIAL TO BE GUARANTEED AS PER PROJECT SPECIFICATIONS.
13. COMPLY WITH ALL OWNER SAFETY TRAINING REQUIREMENTS AND SITE
PROCEDURES, AND COORDINATE THE FOREGOING WITH OWNER'S
DESIGNATED REPRESENTATIVES.
14. PERFORM ALL WORK WITHOUT INTERFERING WITH OWNER'S NORMAL
OPERATIONS.
15. PROJECT DOCUMENTS ARE INTENDED TO BE COMPLEMENTARY. ITEMS
INDICATED IN ONE PLACE OR ANOTHER AMONG THE DOCUMENTS ARE
INTENDED AS THOUGH SHOWN IN ALL PLACES.
16. COORDINATE ALL NEW WORK WITH ALL EXISTING CONDITIONS.
EXISTING ELEMENTS AFFECTING THE WORK REQUIRE SUCH
COORDINATION WHETHER OR NOT THEY ARE INDICATED IN THE
DOCUMENTS
17. DO NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES.
18. ALL WORK IS GUARANTEED FOR A PERIOD OF FIVE YEARS FROM DATE
OF SUBSTANTIAL COMPLETION.
1. UNOBSTRUCTED ACCESS TO EXISTING EMERGENCY EXITS SHALL BE
MAINTAINED AT ALL TIMES.
2. ALL DEBRIS AND UNUSED MATERIAL RESULTING FROM DEMOLITION
SHALL BE DISPOSED OF OFF SITE IN COMPLIANCE WITH ALL LOCAL,
STATE, AND FEDERAL AUTHORITIES.
3. REMOVE EXISTING PARTITIONS, EQUIPMENT, & DEVICES AS
INDICATED.
4. REMOVAL OF EXISTING HVAC & PLUMBING FIXTURES & SAFING TO BE
BY APPROPRIATE TRADES.
5. COORDINATE LOCATION OF ALL NEW FLOOR & WALL PENETRATIONS
WITH OWNER PRIOR TO CUTTING OR CORING. COORDINATE
LOCATION WITH CONSTRUCTION DRAWINGS. SEAL ALL
PENETRATIONS.
6. ALL CONTRACTORS ARE TO REPORT ALL UNEXPECTED, UNCOVERED
EXISTING CONDITIONS WHICH IMPACT LAYOUT OF NEW WORK
IMMEDIATELY TO ARCHITECT.
7. FOR EXTENT & SCOPE OF PLUMBING, MECHANICAL & ELECTRICAL
REMOVALS, SEE INDIVIDUAL TRADE DRAWINGS.
8. SAW CUT ALL NEW OPENINGS IN EXISTING CONSTRUCTION. DO NOT
HAMMER & CHISEL. CARE MUST BE TAKEN NOT TO DAMAGE EXISTING
CONSTRUCTION. COORDINATE TIME OF LOUD/HEAVY NOISE
CONSTRUCTION WITH OWNER TO LIMIT DISTURBANCE.
9. PROVIDE PORTABLE LIGHTING DURING DEMOLITION & CONSTRUCTION
AS REQUIRED.
10. PROVIDE DUMPSTERS AND OTHER DEMOLITION EQUIPMENT AS
REQUIRED.
11. REMOVE EXISTING WORK AS REQUIRED TO ACCOMMODATE NEW
WORK, INCLUDING EXISTING WALL & FLOOR FINISHES IN SPACES
SCHEDULED TO BE REFINISHED.
12. PROVIDE APPROPRIATE FULL HEIGHT PROTECTION/TEMPORARY
PARTITIONS PRIOR TO COMMENCING DEMOLITION. PLACED IN
LOCATIONS APPROVED BY OWNER.
13. ALL BUILDING ACCESS AND REMOVAL OF MATERIALS MUST BE
APPROVED BY OWNER.
NEW
EXIST
DEMOLISHED
WEATHER BARRIER
DAMPPROOFING
VAPOR BARRIER
APPLICABLE CODES:
MARYLAND BUILDING PERFORMANCE STANDARD (MBPS)
INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018
CHAPTER 7, LEVEL 1 ALTERATION
INTERNATIONAL BUILDING CODE (IBC) 2018
INTERNATIONAL MECHANICAL CODE (IMC) 2018
INTERNATIONAL PLUMBING CODE (IPC) 2018
NATIONAL ELECTRIC CODE (NEC) 2020
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101, 2018
NFPA 1, 2018
ABV ABOVE
AC AIR CONDITIONING
ACST ACOUSTIC
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AL ALUMINUM
ALT ALTERNATE
ARCH ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ASSN ASSOCIATION
ASST ASSISTANT
ASSY ASSEMBLY
AVE AVENUE
AVG AVERAGE
B BOTTOM
BALC BALCONY
BD BOARD
BETW BETWEEN
BLDG BUILDING
BLKG BLOCKING
BLR BOILER
BM BEAM
BM BENCHMARK
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BSMT BASEMENT
CAB CABINET
CAP CAPACITY
CDR COILING DOOR
CER CERAMIC
CFCI CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED
CFGI CONTRACTOR FURNISHED, GOVERNMENT
INSTALLED
CI CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMIU CONCRETE MASONRY INSULATED UNIT
CMU CONCRETE MASONRY UNIT
CNCL CONCEALED
CO CLEANOUT
CO COMPANY
COL COLUMN
COMP COMPOSITION
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CRV CURVED
CSK CONTERSINK/COUNTERSUNK
CTD COATED
CTR CENTER
CUH CABINET UNIT HEATER
D DEPTH
DBL DOUBLE
DEG DEGREE
DEP DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DMPF DAMPPROOFING
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
MATERIALS LEGEND
SYMBOLS LEGEND
ABBREVIATIONS
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
A001GENERAL NOTES, SYMBOLS,
LEGENDS & ABBREVIATIONS
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
E EAST
E.G. FOR EXAMPLE
EA EACH
EF EXHAUST FAN
EGEN EMERGENCY GENERATOR
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATE
FBD FIBERBOARD
FD FLOOR DRAIN
FDN FOUNDATION
FDR FIRE DOOR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHY FIRE HYDRANT
FIN FINISH
FL FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FLRG FLOORING
FP FIREPROOF
FRP FIBER-REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FTG FOOTING
FURN FURNITURE
GA GAUGE / GAGE
GALV GALVANIZED
GAR GARAGE
GEN GENERATOR
GFCI GOVERNMENT FURNISHED, CONTRACTOR
INSTALLED
GFGI GOVERNMENT FURNISHED, GOVERNMENT
INSTALLED
GL GLASS
GLU-LAM GLUE-LAMINATED
GOVT GOVERNMENT
GR GRADE
GRD GROUND
GVL GRAVEL
GYP GYPSUM
H HIGH
HDWE HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HPT HIGH POINT
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
I.E. THAT IS
ICF INSULATED CONCRETE FORM
ID INSIDE DIAMETER
IH INTAKE HOOD
INSUL INSULATED
INTR INTERIOR
JST JOIST
JT JOINT
L LONG
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LG LENGTH
LH LEFT HAND
LIB LIBRARY
LIN LINEAR
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LT LIGHT
LWC LIGHTWEIGHT CONCRETE
M METER
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MGR MANAGER
MH MANHOLE
MIL MILITARY
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LATH
MLDG MOLDING
MLP METAL LATH AND PLASTER
MM MILLIMETER
MO MASONRY OPENING
MOD MOTOR OPERATED DAMPER
MTG MOUNTING
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NRC NOISE-REDUCTION COEFFICENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OHDR OVERHEAD DOOR
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
P/L PROPERTY LINE
PASS PASSENGER
PERF PERFORATED
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PORC PORCELAIN
PR PAIR
PREFAB PREFABRICATED
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHOLRIDE
QTF QUARRY TILE FLOOR
R RADIUS
R RISER
RD ROOF DRAIN
RECP RECEPTACLE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RET RETURN
REV REVISION
RFG ROOFING
RH RIGHT HAND
RM ROOM
RWC RAIN WATER CONDUCTOR
GENERAL NOTESGENERAL DEMOLITION NOTES
S SOUTH
SAPC SUSPENDED ACOUSTICAL PANEL CEILING
SCHED SCHEDULE
SDG SIDING
SEC SECTION
SF SQUARE FOOT
SGFT STRUCTURAL GLAZED FACING TILE
SH SHOWER
SHM SECURITY HOLLOW METAL
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SIM SIMILAR
SKY SKYLIGHT
SLDR SLIDING DOOR
SMLS SEAMLESS
SPA SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
STWY STAIRWAY
SUPT SUPERINTENDENT
SUPVR SUPERVISOR
SURF SURFACE
SUSP SUSPENDED / SUSPENSION
SYS SYSTEM
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/ TOP OF
TAN TANGENT
TEL TELEPHONE
TEMP TEMPERORARY
TER TERRAZZO
THRU THROUGH
TLT TOILET
TRTD TREATED
TYP TYPICAL
UNO UNLESS NOTED OTEHRWISE
VAT VINYL ASBESTOS TILE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VERTICAL
W WEST
W WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDR WOOD DOOR
WH WATER HEATER
WTRPRF WATERPROOFING
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
LINETYPE LEGEND
CODE SUMMARY
NO. DESCRIPTION DATE BY
74'-4" 178'-4"
88 811 11
28'-6" 31'-7" 60'-5" 28'-4" 32'-2 3/8"
AD1012
AD101
AD101
AD102
AD102 3
AD102 4
AD102 5
1. REMOVE MODIFIED BITUMEN ROOF SYSTEM AND INSULATION DOWN
TO ROOF DECK.
2. REMOVE METAL COPING AND ACCESSORIES.
3. EXISTING METAL ROOFING. CLEAN ROOF OF RUST AND DEBRIS.
REMOVE ALL AFTER MARKET COATINGS FROM ROOF.
4. REMOVE ROOF HATCH, CURB AND BLOCKING.
5. REMOVE AND SALVAGE MECH EQUIPMENT FOR REINSTALLATION.
PROTECT DURING CONSTRUCTION. SEE MECH DWGS.
6. EXISTING PIPE CURB ASSEMBLY.
7. EXISTING VENT STACK.
8. REMOVE SCUPPER, COLLECTOR BOX, AND DOWNSPOUT.
9. EXISTING MECH EQUIPMENT.
10. REMOVE STANDING SEAM METAL COPING AND ACCESSORIES.
11. PROVIDE OPENING IN PARAPET FOR NEW SCUPPER. REMOVE
SECTION OF CONC SIDEWALK, SEE SHEET AD102.
12. REMOVE DRAIN, DOWNSPOUT, AND ACCESSORIES.
13. REMOVE METAL WALL PANELS ENTIRE LENGTH OF WALL.
1. INSPECT SUBSTRATE AND NOTIFY ARCHITECT / OWNER OF ANY
DEFICIENCIES.
9 86 4
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
AD101
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
ROOF PLAN - DEMOLITION
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
NO. DESCRIPTION DATE BY
SCALE: 3/32" = 1'-0"
ROOF PLAN - DEMOLITION
ROOF KEYNOTES#
SHEET GENERAL ROOF NOTES
SCALE: NTS
ROOF 1 - DEMOLITION
SCALE: NTS
ROOF 2 - DEMOLITION
SCALE: NTS
ROOF 2 - DEMOLITION
REMOVE 5' x 5' AREA OF CONC
SIDEWALK FOR NEW DRAINLINE.
COORDINATE W/ NEW WORK
REMOVE DOWNSPOUT
REMOVE FUNNEL
TRANSITION
EXIST PIPE BELOW
GRADE TO REMAIN
REMOVE DOWNSPOUT
REMOVE CORRUGATED
TRANSITION
EXIST PIPE BELOW
GRADE TO REMAIN
REMOVE DOWNSPOUT
REMOVE CORRUGATED
TRANSITION
EXIST PIPE BELOW
GRADE TO REMAIN
REMOVE DOWNSPOUT
REMOVE CORRUGATED
TRANSITION
EXIST PIPE BELOW
GRADE TO REMAIN
RECONNECT ALL
CONDENSATE OR OTHER
DRAIN LINES CURRENTLY
ATTACHED TO EXIST
DOWNSPOUTS TO NEW
DOWNSPOUTS
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
AD102
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
SITE & DOWNSPOUT DEMOLITION
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
NO. DESCRIPTION DATE BY
SCALE: NTS
SITE - DEMOLITION
SCALE: NTS
ROOF 1 DOWNSPOUT - DEMOLITION
SCALE: NTS
ROOF 2 DOWNSPOUT - DEMOLITION
SCALE: NTS
ROOF 2 DOWNSPOUT - DEMOLITION
SCALE: NTS
ROOF 2 DOWNSPOUT - DEMOLITION
178'-4"
A501
66 6
A501
A501
A501
E X
IS
T
D E
C K
S L O
P E
1/A102
1/A102
/4
P
E R
F O
O T
E X
IS
T
D E
C K
S L O
P E
/4
P
E R
F O
O T
8 8
1. ROOF ASSEMBLY #1 - ROOFING SYSTEM INSTALLED ON SLOPED METAL
DECK INCLUDES:
A. TPO MEMBRANE - FULLY ADHERED
B. 1/2" COVER BOARD - MECHANICALLY FASTENED
C. 5" CONT INSULATION (R-28.5) - FULLY ADHERED
D. VAPOR RETARDER - PEEL 'N' STICK
E. 1/2" DECK BOARD - MECHANICALLY FASTENED
2. REINSTALL METAL COPING.
3. REINSTALL MECH EQUIPMENT. SEE MECH DWGS.
4. PROVIDE ROOF HATCH TO MATCH SIZE OF ROOF OPENING.
5. EXISTING PIPE CURB ASSEMBLY.
6. PROVIDE SCUPPER, COLLECTOR BOX, AND DOWNSPOUT W/ REDUCER.
CONNECT REDUCER W/ EXISTING PVC DRAINLINE.
7. EXISTING MECH EQUIPMENT. SEE MECH DWGS.
8. PROVIDE SCUPPER, COLLECTOR BOX, AND DOWNSPOUT W/ REDUCER.
CONNECT REDUCER W/ NEW PVC DRAINLINE. RUN DRAINLINE BENEATH
EXISTING CONC WALK TO MATCH EXISTING. PROVIDE NEW CONC
SIDEWALK SECTION.
9. 30" WIDE ROOF MEMBRANE WALKWAY.
ROOF 1
ROOF 2
TPO MEMBRANE
1/2" COVER BOARD
5" RIGID INSUL
EXIST METAL DECK
1/2" DECK BOARD
VAPOR RETARDER
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
A101
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
ROOF PLAN - ROOF 1
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
SCALE: 1/8" = 1'-0"
ROOF PLAN - ROOF 1
NO. DESCRIPTION DATE BY
ROOF KEYNOTES#
KEYPLAN
SCALE: 3" = 1'-0"
ROOF ASSEMBLY 1
/4
A501
A501
A501
A501
EXIST ROOF SLOPE
1/A101
1/A101
73'-4"
1/4" PER FOOT
EXIST ROOF SLOPE
1/4" PER FOOT
A501
A501
TYP
A501
TPO MEMBRANE
1/2" COVER BOARD
2" RIGID INSUL
EXIST METAL ROOF
1. ROOF ASSEMBLY #2 - ROOFING SYSTEM INSTALLED ON METAL ROOFING
INCLUDES:
A. TPO MEMBRANE - FULLY ADHERED
B. 1/2" COVER BOARD - MECHANICALLY FASTENED
C. 2" RIGID INSULATION (R-11.4) - FULLY ADHERED
2. PROVIDE NEW METAL COPING.
3. EXISTING MECH EQUIPMENT. SEE MECH DWGS.
4. EXISTING VENT STACK.
5. PROVIDE DRAIN, DOWNSPOUT, SS GUTTER AND ACCESSORIES - MATCH
EXISTING. PROVIDE CORRUGATED BOOT TRANSITION BETWEEN DS AND
EXIST PIPE BELOW GRADE - MATCH EXISTING.
6. 30" WIDE ROOF MEMBRANE WALKWAY.
ROOF 1
ROOF 2
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
A102
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
ROOF PLAN - ROOF 2
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
NO. DESCRIPTION DATE BY
SCALE: 1/8" = 1'-0"
ROOF PLAN - ROOF 2
SCALE: 3" = 1'-0"
ROOF ASSEMBLY 2
ROOF KEYNOTES#
KEYPLAN
JOIST BEARING
12' - 8"
EXIST 8" CMU
EXIST WD BLOCKING
ROOFING MEMBRANE
FLASHING
REMOVE METAL FASCIA,
SALVAGE AND REINSTALL AFTER
INSTALLATION OF NEW WORK
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
1/2" DECK BOARD
EXIST METAL DECK
EXIST METAL
ROOF JOIST
COLLECTOR BOX
4"x5" DOWNSPOUT
SCUPPER,
MATCH EXIST
FLASHING
STANDING SEAM ROOF PANEL
MTL ROOF PANEL FLASHING
ROOF TRIM
Z FLASHING
WD BLOCKING
2'-9 1/2"
VAPOR RETARDER
SCUPPER SCREEN
EXIST 8" CMU
EXIST WD BLOCKING
STANDING SEAM ROOF PANEL
ROOFING MEMBRANE
FLASHING
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
1/2" DECK BOARD
EXIST METAL DECK
EXIST METAL
ROOF JOIST
LAP SEALANT
MTL ROOF PANEL FLASHING
ROOF TRIM
Z FLASHING
WD BLOCKING
2'-9 1/2"
VAPOR RETARDER
EXIST 8" CMU
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL FASCIA
ROOFING MEMBRANE FLASHING
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
1/2" DECK BOARD
EXIST METAL DECK
EXIST METAL
ROOF JOIST
LAP SEALANT
CONT CLEAT
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
EXIST METAL ROOF
CONT MEMBRANE FLASHING
F L A
S H
IN
G
H E
IG
H
T V
A R
IE
S
P A
R A
P E
T R
O O
F
IN
G M
E M
B R
A N
E
VAPOR RETARDER
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL FASCIA
CONT CLEAT
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
EXIST METAL ROOF
CONT MEMBRANE FLASHING
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL COPING
CONT CLEAT
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
EXIST METAL ROOF
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
REMOVE EXIST
METAL WALL PANEL
CONT CLEAT
1/2" WALL SHEATHING
1'-0 1/2"
V A
R
IE
S
ROOFING
MEMBRANE FLASHING
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL COPING
CONT CLEAT
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
EXIST METAL ROOF
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
CONT CLEAT
COUNTERFLASHING
SS GUTTER LINER
CONT MEMBRANE FLASHING
METAL DRIP EDGE
ROOFING MEMBRANE FLASHING
1/2" WALL SHEATHING
1'-1 1/2"
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL COPING
CONT CLEAT
ROOFING MEMBRANE
1/2" COVER BOARD
RIGID INSULATION
EXIST METAL ROOF
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
ROOFING MEMBRANE FLASHING
CONT CLEAT
COUNTERFLASHING
SS ROOF DRAIN
W/ FLANGE
CONT MEMBRANE FLASHING
METAL DRIP EDGE
10 3/4"
SS GUTTER LINER
4"x5" DOWNSPOUT
1/2" WALL SHEATHING
Sim
A501
2x WD OR DBL 3/4"
PLYWD BLOCKING
METAL COPING
CONT CLEAT
EXIST METAL FASCIA
BATTEN & PANEL SYSTEM
CONT CLEAT
EXIST COUNTERFLASHING
METAL DRIP EDGE
ROOFING MEMBRANE
FLASHING
1/2" WALL SHEATHING
WD BLOCKING
AS REQUIRED
SS GUTTER LINER
LAP SEALANT
1/2" COVER BOARD
2" 4" 2"
FLANGE FOR
ATTACHING TO
SS GUTTER LINER
SS WIRE STRAINER
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
A501
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
DETAILS
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
NO. DESCRIPTION DATE BY
SCALE: 1 1/2" = 1'-0"
SCUPPER DETAIL - ROOF 1
SCALE: 1 1/2" = 1'-0"
PARAPET DETAIL - ROOF 1
SCALE: 1 1/2" = 1'-0"
PARAPET DETAIL - ROOFS 1 & 2
SCALE: 1 1/2" = 1'-0"
FASCIA DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
PARAPET DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
PARAPET DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
GUTTER DRAIN DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
PARAPET DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
PLAN
BASE FLASHING
MEMBRANE ROOFING
SURFACE MOUNTED
COUNTERFLASHING
5" RIGID INSUL
1/2" DECK BOARD
EXIST METAL DECK
1/2" COVER BOARD
ROOF HATCH
CURB WITH INTERGRAL
CAP FLASHING
EXIST LADDER
WD BLOCKING
AS REQ'D
INSULATED EQUIP CURB
ROOFING MEMBRANE
5" RIGID INSUL
MEMBRANE FLASHING
EXIST MECH EQUIP
EXIST METAL DECK 2x WD BLOCKING
COUNTERFLASHING
1/2" COVER BOARD
1/2" DECK BOARD
M
IN
ROOFING MEMBRANE
2" RIGID INSUL
LAP SEALANT
PRE-MOLDED
PIPE SEAL
STAINLESS STEEL
CLAMPING RING
WATER CUT-
OFF MASTIC
EXIST VENT PIPE
EXIST METAL
ROOFING
1/2" COVER BOARD
EXIST EQUIP CURB
ROOFING MEMBRANE
2" RIGID INSUL
MEMBRANE FLASHING
EXIST MECH EQUIP
EXIST METAL ROOF
COUNTERFLASHING
1/2" COVER BOARD
EXIST EQUIP CURB
ROOFING MEMBRANE
5" RIGID INSUL
MEMBRANE FLASHING
EXIST MECH EQUIP
COUNTERFLASHING
1/2" COVER BOARD
EXIST METAL DECK
1/2" DECK BOARD
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9
/2
:0
:2
A
M
A u to d e s k D o c s /0
-M
D O
T M
V A
V
M
U L /0
-0
A c e n tr a l_
R .r v t
A502
12/09/2022JEF
DREDRE 067196-06
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
JEF
DETAILS
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
-0
NO. DESCRIPTION DATE BY
SCALE: 1 1/2" = 1'-0"
ROOF HATCH DETAIL
SCALE: 1 1/2" = 1'-0"
EQUIP CURB DETAIL - ROOF 1
SCALE: 1 1/2" = 1'-0"
VENT STACK DETAIL
SCALE: 1 1/2" = 1'-0"
EXIST EQUIP CURB DETAIL - ROOF 2
SCALE: 1 1/2" = 1'-0"
EXIST EQUIP CURB DETAIL - ROOF 1
1. NOT ALL ABBREVIATIONS, LINE TYPES, OR SYMBOLS MAY APPEAR ON THESE
CONTRACT DOCUMENTS.
2. DRAWINGS SHALL BE CONSIDERED DIAGRAMMATIC AND ARE INTENDED TO
INDICATE CAPACITY, SIZE, APPROXIMATE LOCATION AND GENERAL ARRANGEMENT.
WHILE THE DRAWINGS ARE GENERALLY TO SCALE AND ARE AS ACCURATE AS THE
SCALE WILL PERMIT, DIMENSIONS SHALL BE CONFIRMED IN THE FIELD.
3. THE CONTRACTOR SHALL COMPLY WITH THE LAWS, ORDINANCES, RULES AND
REGULATIONS OF LOCAL AND STATE GOVERNMENTAL AUTHORITIES; OF THE
NATIONAL FIRE PROTECTION ASSOCIATION AS INTERPRETED BY THE ENFORCING
AUTHORITY HAVING JURISDICTION; AND OF PUBLIC UTILITIES HAVING CONNECTION
WITH ANY OF THE SYSTEMS HEREIN SPECIFIED.
4. INSTALL EQUIPMENT IN A SERVICEABLE MANNER WITHOUT DISRUPTION TO
ADJACENT SERVICES OR DAMAGING INSULATION. THIS INCLUDES, BUT IS NOT
LIMITED TO: PROVIDE VALVE OPERATOR EXTENSIONS TO EXTEND THRU THE
INSULATION AND HANDLES TO SWING TOWARD THE OPERATOR FOR ISOLATION.
5. PROVIDE ALL NEW AND REUSED WALL PENETRATIONS WITH A SLEEVE/CONDUIT
FOR SERVICES PENETRATING IT. THIS INCLUDES, BUT IS NOT LIMITED
TO: DUCTWORK, PIPING, POWER, AND CONTROL WIRING.
6. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS
REQUIRED BY ANY OF THE FOREGOING AUTHORITIES, AND PAY FOR ALL OTHER
COSTS IN CONNECTION WITH THE WORK. CERTIFICATES SHALL BE IN DUPLICATE
AND SHALL BE DELIVERED TO THE OWNER.
7. THE SITE, LOCATION, AND ROUTING OF SYSTEMS INDICATED TO HAVE NEW
CONNECTIONS MADE TO THEM ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS
PERMIT. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY EXAMINE THE
CONTRACT DRAWINGS. ALL EXISTING CONDITIONS SHALL BE EXAMINED AND THEIR
EXACT LOCATIONS VERIFIED. THE CONTRACTOR SHALL REPORT TO THE ENGINEER
ANY CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A
PROBLEM. NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE
TO INVESTIGATE CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTUAL
REQUIREMENTS.
8. THE CONTRACTOR SHALL INSTALL AND CONNECT EQUIPMENT AND MATERIALS IN
ACCORDANCE WITH THE BEST ENGINEERING PRACTICE AND, UNLESS OTHERWISE
SHOWN OR SPECIFIED, FOLLOW THE MANUFACTURER'S PRINTED INSTALLATION
REQUIREMENTS AND RECOMMENDATIONS, AND FURNISH AND INSTALL REQUIRED
AUXILIARY ITEMS TO PROVIDE A COMPLETE INSTALLATION.
9. THE CONTRACTOR SHALL REPAIR WALLS, CEILING, FLOORS, ETC., THAT ARE
REQUIRED TO BE PENETRATED, OR OTHERWISE DISTURBED. THE REPAIRS SHALL
BE WITH MATERIALS AND FINISHES TO MATCH EXISTING. FIRE WALL PENETRATIONS
SHALL BE SEALED WITH SUITABLE MATERIALS TO PRESERVE FIRE WALL INTEGRITY.
10. THE CONTRACTOR SHALL REMOVE EQUIPMENT NOT INDICATED TO BE REUSED TO
A DESIGNATED LOCATION AT THE PROJECT SITE. AFTER THE EQUIPMENT HAS BEEN
ASSEMBLED FOR THE OWNER'S INSPECTION AND POSSIBLE RETENTION, ALL
EQUIPMENT NOT TO BE RETAINED BY THE OWNER SHALL BE REMOVED FROM THE
SITE BY THE CONTRACTOR.
11. COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE AMONG
MECHANICAL, ELECTRICAL, ARCHITECTURAL AND STRUCTURAL, PLUMBING, ETC.
PROVIDE NECESSARY OFFSETS IN PIPING, DUCTWORK AND FITTINGS ETC.,
REQUIRED TO PROPERLY INSTALL WORK WITHOUT INTERFERENCES.
12. BUILDING SYSTEMS SHALL REMAIN IN SERVICE UNLESS INDICATED OTHERWISE.
OUTAGES OR INTERRUPTIONS SHALL BE KEPT TO A MINIMUM DURATION. NOTIFY
THE OWNER 48 HOURS IN ADVANCE OF ANY OUTAGE OR INTERRUPTION. IF
TEMPORARY CONNECTIONS ARE NECESSARY TO ASSURE THIS CONTINUITY OF
SERVICES, THEY SHALL BE FURNISHED BY THE CONTRACTOR WITHOUT ADDITIONAL
CHARGE TO THE OWNER AND SHALL BE REMOVED WHEN NO LONGER NEEDED.
13. THE CONTRACTOR SHALL ARRANGE AND EXECUTE HIS WORK SUCH THAT ANY
CONNECTIONS, BOTH TEMPORARY OR PERMANENT, TO, OR REARRANGEMENT OF,
PRESENT EQUIPMENT, PIPING, ETC., SHALL BE MADE IN SUCH A MANNER AS TO
ASSURE FULL RESUMPTION OF SERVICE AT THE TIME DESIGNATED BY THE OWNER.
14. THE CONTRACTOR SHALL LOCATE EQUIPMENT WHICH MUST BE SERVICED,
OPERATED OR MAINTAINED IN FULLY ACCESSIBLE POSITIONS. FURNISH ACCESS
DOORS AS REQUIRED FOR BETTER ACCESSIBILITY. MINOR DEVIATIONS FROM
DRAWINGS MAY BE MADE TO ALLOW FOR ACCESSIBILITY, BUT CHANGES OF
MAGNITUDE WHICH INVOLVE EXTRA COSTS SHALL NOT BE MADE WITHOUT
WRITTEN APPROVAL.
15. ALL DIMENSIONS FOR EXISTING PIPING AND DUCTWORK SHALL BE VERIFIED IN THE
FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION, WHERE NEW WORK
CONNECTIONS ARE INDICATED. NEW DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR
DIMENSIONS.
16. OPENINGS REMAINING IN EXISTING PIPING/DUCTWORK AS A RESULT OF
DEMOLITION SHALL BE SEALED WITH AN AIRTIGHT/WATERTIGHT SHEET METAL CAP.
WHERE EXISTING SYSTEMS ARE INSULATED, WORK SHALL INCLUDE REPAIR AND
REPLACEMENT OF INSULATION EITHER DAMAGED OR REMOVED AS A RESULT OF
DEMOLITION.
17. PIPING SCOPE REQUIREMENTS: HORIZONTAL DRAINAGE PIPING SHALL BE
INSTALLED IN UNIFORM ALIGNMENT AT UNIFORM SLOPES. THE MINIMUM SLOPE OF
HORIZONTAL DRAINAGE PIPE SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
SIZE (INCHES) MINIMUM SLOPE (INCHES PER FOOT)
2-1/2 OR LESS 1/4
3 TO 6 1/8
8 OR LARGER 1/16
1. EXISTING HANGERS SHALL BE MODIFIED TO FACILITATE NEW
ABOVE CEILING WORK.
2. ABANDONED EQUIPMENT SHALL BE REMOVED IN ITS ENTIRETY AS
REQUIRED TO FACILITATE NEW WORK.
SYMBOL
DOUBLE LINE DESCRIPTION
DUCTWORK, SIZE AS INDICATED
DUCTWORK, WITH SOUNDLINING
VANED ELBOW
SUPPLY DUCT TURNING UP AND DOWN
RETURN DUCT TURNING UP AND DOWN
EXHAUST/RELIEF DUCT TURNING UP AND DOWN
DUCT RISE/DROP IN AIRFLOW DIRECTION
DUCT TRANSITION, SQUARE TO SQUARE
DUCT TRANSITION, SQUARE TO ROUND
DUCT CAPPED
45 DEGREE TAP
CONICAL TAP
SPUN-IN RUNOUT FITTING W/ FLEX. & VD
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
FIRE DAMPER
SMOKE DAMPER
BACKDRAFT DAMPER
MOTORIZED DAMPER
RETURN, EXHAUST GRILLE OR REGISTER
SUPPLY AIR DIFFUSER, 4-WAY BLOW
THERMOSTAT, MASTER THERMOSTAT
TEMPERATURE SENSOR
SUPPLY AIR DIFFUSER, 3-WAY BLOW
SUPPLY AIR DIFFUSER, 2-WAY BLOW
SUPPLY AIR DIFFUSER, 1-WAY BLOW
FLEXIBLE CONNECTION
HUMIDISTAT
HUMIDITY SENSOR
DUCT SMOKE DETECTOR
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
NITROGEN OXIDES SENSOR
SULFUR OXIDES SENSOR
STATIC PRESSURE SENSOR
DUCT ACCESS DOORAD
AD
DUCT CONTINUATION
SUPPLY AIR FLOW DIRECTION
OUTSIDE AIR FLOW DIRECTION
RETURN/EXHAUST AIR FLOW DIRECTION
OA
FREEZESTAT
UN-VANED ELBOW
VANED TEE
UN-VANED TEE
BAROMETRIC DAMPER
GAS CONCENTRATION MONITOR
RADIUS ELBOW
SP
SOx
NOx
CO
CO2
H
HS
FZ
H
TS
TT
R/D
20x12
20x12
F
BD
MD
BDD
S
NEW WORK LINEWEIGHT
EXISTING WORK LINEWEIGHT
FUTURE WORK LINEWEIGHT
DEMOLITION WORK LINEWEIGHT
POINT OF CONNECTION
TERMINATION POINT OF DEMOLITION
SHEET NOTE REFERENCE
REVISION REFERENCE
M301
INDICATES PLAN/DETAIL NUMBER
PLAN/DETAIL TITLE
SCALE (AS REQUIRED)
INDICATES PLAN/DETAIL NUMBER
INDICATES DRAWING ON WHICH
DRAWING SECTION APPEARS
VAV/AIR VALVE TAG
8"
VAV-1
DESIGNATION
DUCT INLET/PIPE SIZE
CFM/GPM
EQUIPMENT TAGE-1
VIEW TITLE
SCALE:
NORTH ARROW
DIFFUSER, REGISTER, OR GRILLE
DESIGNATION AND AIRFLOW TAG(S)150
8"
CD-1
TYPE
CFM
CD-1
CD-1-150
NECK
POINT OF FUTURE CONNECTION
AREA OF DEMOLITION
DESCRIPTION
STRAINER WITH DRAIN VALVE AND CAP
GEN. SHUTOFF VALVE (BALL, GATE, BUTTERFLY)
GATE VALVE
CHECK VALVE
BALL VALVE
BUTTERFLY VALVE
GAS COCK
STRAINER
PRESSURE REDUCING VALVE
CALIBRATED BALANCING VALVE
CONTROL VALVE, TWO-WAY (ELECTRIC)
CONTROL VALVE, THREE-WAY (ELECTRIC)
THREE-WAY MANUAL VALVE
SOLENOID VALVE
RELIEF/SAFETY VALVE
SYMBOL
s
GLOBE VALVE
OUTSIDE STEM & YOKE VALVE
PRESSURE GAUGE WITH COCK
THERMOMETER
PRESSURE/TEMPERATURE TEST PORT
AQUASTAT
NORMALLY CLOSED PORT (NC)
CONTROL VALVE, TWO-WAY (PNEUMATIC)
CONTROL VALVE, THREE-WAY (PNEUMATIC)
AUTOMATIC AIR VENT (EXTEND TO DRAIN)
MANUAL AIR VENT
AAV
MAV
FUSOMATIC GATE VALVE
F
SYMBOL DESCRIPTION
PIPING TURNING DOWN
PIPE BRANCH TOP TAKEOFF
CAP
PIPE RISER UP/DOWN
PIPING TURNING UP
PIPE BRANCH BOTTOM TAKEOFF
TEE DOWN
FLOW DIRECTION
R/D
PIPE SLOPE RISE/DROP
CONCENTRIC REDUCER/INCREASER
ECCENTRIC REDUCER/INCREASER (FOB)
UNION
, PIPE CONTINUATION
DIFFERENTIAL PRESSURE TRANSDUCER
TEMPERATURE SENSOR
PRESSURE SENSOR
FLOW SWITCH
FLOW METER
PUMP
VALVE IN VERTICAL PIPE
T
P
DP
FS
FM
GENERAL NOTES
AAV AUTOMATIC AIR VENT
ABV ABOVE
AD AREA DRAIN, ACCESS DOOR, AIR
DRYER
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUST, ADJUSTABLE
AF ANTI-FREEZE
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
AP ACCESS PANEL
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
AVG AVERAGE
BA BREATHABLE AIR
BAS BUILDING AUTOMATION SYSTEM
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BLDG BUILDING
BLW BELOW
BMS BUILDING MANAGEMENT SYSTEM
BOD BASIS OF DESIGN
BOT BOTTOM
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
C COMMON
CA COMPRESSED AIR
CD CONDENSATE DRAIN
CFH CUBIC FEET PER HOUR
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CI CAST IRON
CL CENTER LINE
CLDIP CEMENT-LINED DUCTILE IRON S PIPE
CLNG CEILING
CONN CONNECTION
CONT CONTINUATION
CONT'D CONTINUED
CPVC CHLORINATED POLYVINYL CHLORIDE
CV CLEANING VACUUM, CHECK VALVE
CW COLD WATER
Cx
CxA COMMISSIONING AUTHORITY
(D) DEMOLISH, REMOVE
D DRAIN, DEPTH
DB DECIBELS
DCW DOMESTIC COLD WATER
DDC DIRECT DIGITAL CONTROL
DEG, ° DEGREES
DEPT DEPARTMENT
DESG DESIGNATION
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DIA, ø DIAMETER
DIFF DIFFERENTIAL, DIFFERENCE
DISC DISCONNECT
DN DOWN
DSB DOWNSPOUT BOOT
DSN DOWNSPOUT NOZZLE
DWG DRAWING
(ER) EXISTING RELOCATED
(EX) EXISTING TO REMAIN
EA EACH
EFF EFFICIENCY
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EXT EXTERIOR
(F) FUTURE
FCO FLOOR CLEANOUT
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDR FLOOR DRAIN
FF FINISHED FLOOR
FG FUEL GAS
FLA FULL LOAD AMPS
FLEX FLEXIBLE
FLR FLOOR
FM FLOW METER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOW SWITCH
FT HD FEET OF HEAD
FT, ‘ FOOT, FEET
FZ FREEZE, FREEZSTAT
°F DEGREES FAHRENHEIT
G GAS
GA GAUGE
GAL GALLON, GALLONS
GALV GALVANIZED
GEN GENERATOR
GI GREASE INTERCEPTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GW GREASE WASTE
H HEIGHT
H2O WATER
HB HOSE BIB
HORIZ HORIZONTAL
HP HORSEPOWER
HPS HIGH PRESSURE STEAM
HTG HEATING
HUM HUMIDIFIER
HX HEAT EXCHANGER
HZ HERTZ (CYCLES PER SECOND)
ID INSIDE DIAMETER
IN WG INCHES OF WATER GAUGE
IN, “ INCH, INCHES
INFO INFORMATION
INFO INFORMATION
INT INTERIOR
ABBREVIATIONS
GENERAL DEMOLITION NOTES
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9 /2
:0
:4
P
M
A u to d e s k D o c s /0
-M D
O T
M
V A
V
M
U L
/0
-0
M E
P C e n tr a l_ R
.r v t
M001LEGEND, GENERAL NOTES &
ABBREVIATIONS
12/09/2022PWH
ATPWH 067196
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
PWH
MECHANICAL
P ro je c t N u m b e r:
INT INTERIOR
INV EL INVERT ELEVATION
ISOL ISOLATION
KW KILOWATTS
L LENGTH, LONG
LAV LAVATORY
LBS POUNDS
LDR LEADER
LP LIQUID PROPANE
LPCR LOW PRESSURE CONDENSATE RETURN
LPS LOW PRESSURE STEAM
LRA LOAD RATED AMPS
LWT LEAVING WATER TEMPERATURE
M METER
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH THOUSAND BRITISH THERMAL UNITS
PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MOTOR OIL
MPS MEDIUM PRESSURE STEAM
MTD MOUNTED
MTG MOUNTING
MUW MAKE UP WATER
N NITROGEN
N/A NOT APPLICABLE
NC NORMALLY CLOSED, NOISE CRITERIA
NFPA NATIONAL FIRE PROTECTION AGENCY
NFWH NON-FREEZE WALL HYDRANT
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPENED
No NUMBER
NOM NOMINAL
NPW NON-POTABLE WATER
NTS NOT TO SCALE
OC ON CENTER
OFD OVERFLOW DRAIN
OS&Y OUTSIDE STEM AND YOKE VALVE
OSD OPEN SITE DRAIN
OVH OVERHEAD
OWS OIL WATER SEPARATOR
P PUMP
PC PUMPED CONDENSATE
PD PRESSURE DROP
PH PHASE
PIW PUMPED INDUSTRIAL WASTE
PLBG PLUMBING
PNEU PNEUMATIC
POS POSITION
PRESS PRESSURE
PROP PROPELLER
PRV PRESSURE REDUCING VALVE
PS PRESSURE SWITCH
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PVC POLYVINYL CHLORIDE
(RL) RELOCATE, RELOCATED POSITION
R RISE
RD ROOF DRAIN, REFRIGERANT
DISCHARGE
REQ'D REQUIRED
RL REFRIGERANT LIQUID
RLA RATED LOAD AMPS
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPZ REDUCED PRESSURE BFP
RS REFRIGERANT SUCTION
S SWITCH
S/S START/STOP
SAN SANITARY
SF SUPPLY FAN, SQUARE FEET
SK SINK
SP STATIC PRESSURE
SPEC SPECIFICATION
SPR SPRINKLER
SQ SQUARE
SQ FT SQUARE FOOT, SQUARE FEET
SS STAINLESS STEEL
ST STORM WATER PIPING
STD STANDARD
STL STEEL
TEMP TEMPERATURE, TEMPORARY
TP TRAP PRIMER
TW TEPID WATER
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
V VOLTS, VENT
VCO VERTICAL CLEAN OUT
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VIB VIBRATION
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WIDTH, WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCO WALL CLEANOUT
WH WATER HEATER, WALL HYDRANT
WPD WATER PRESSURE DROP
WSHP WATER SOURCE HEAT PUMP
WT WEIGHT
ZN ZONE
(RL)RTU-1
(E) EXHAUST FAN
(E) EXHAUST FAN
(E) CONDENSING UNIT
(E) OUTSIDE AIR INTAKE HOOD
(E) OUTSIDE AIR INTAKE HOOD
(E) OUTSIDE AIR INTAKE HOOD
ROOF HATCH
(E)4" Ø V (E)4" Ø V
(E)4" Ø V
(E)3" Ø V
(E)4" Ø V
(D)RTU-2
MD101
SHEET DEMOLITION NOTES
1. DISCONNECT RTU-1 FROM POWER WIRING, CONTROL WIRING,
NATURAL GAS PIPING, CONDENSATE DRAIN, AND DUCTWORK.
2. REMOVE RTU-1 AND SET ON GRADE (TO BE RE-INSTALLED).
REMOVE EXISTING RTU-1 CURB ADAPTER AND ROOF CURB.
DISCONNECT AND DEMOLISH EXISTING POWERED EXHAUST
UNIT FROM RTU-1.
3. DISCONNECT AND DEMOLISH EXISTING SMOKE DETECTOR IN
RETURN DUCTWORK BEING DEMOLISH AND EXISTING TO REMAIN
SUPPLY DUCTWORK SERVING RTU-1.
4. DISCONNECT EXISTING CEILING RETURN DIFFUSER, TO BE
RELOCATED. CLEAN AND STORE, PREPARE FOR
RECONNECTION.
5. PROVIDE PRE-DEMOLITION TESTING OF AIRFLOW FOR RETURN
AND SUPPLY AIR DUCTWORK MAIN BRANCHES.
6. DISCONNECT RTU-2 FROM POWER WIRING, CONTROL WIRING,
NATURAL GAS PIPING, CONDENSATE DRAIN, AND DUCTWORK.
DEMOLISH RTU-2. ROOF CURB, EXISTING TO REMAIN.
7. DISCONNECT AND DEMOLISH EXISTING SMOKE DETECTORS IN
SUPPLY AND RETURN DUCT FROM RTU-2.
D#
DEMOLISH ROOF CURB
(E)1" Ø CD
(E)3/4" Ø NG
(D)RTU-2
D6D1 D2
(RL)
RTU-1
(E)1" Ø CD
(E)3/4" Ø NG
MD101
_________________________ D3
D4
D5
D5
D5
D5
(D )3
"x
(E)60"x18" - SA
(D)32"x14" -
(E)30"x14" - RA
(E)32"x20" - RA
(D)32"x20" -
RTU-2 (ABOVE),
NO WORK BELOW ROOF
D7
(E )2
"x
R
A (E
)2 "x
R
A
D3
D5
D5
D5
(D)32"x14" -DEMOLISH SMOKE DETECTOR
(D)16"x60" -
DISCONNECT RTU-1
DEMOLISH EXISTING ROOF CURB
EXISTING CEILING
(E)18"x60" - SA
(D) 12"⌀
RELOCATE EXISTING
DIFFUSER
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9 /2
:0
:0
P
M
A u to d e s k D o c s /0
-M D
O T
M
V A
V
M
U L
/0
-0
M E
P C e n tr a l_ R
.r v t
MD101ABOVE CEILING AND ROOF
DEMOLITION PLANS 12/09/2022PWH
ATPWH 067196
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
PWH
MECHANICAL
P ro je c t N u m b e r:
SCALE: 3/32" = 1'-0"
MECHANICAL ROOF OVERALL PLAN - DEMOLITION
8' 16'0'
SCALE: 3/32" = 1'-0"
4' 8'0'
SCALE: 1/4" = 1'-0"
2,3
SCALE: 1/4" = 1'-0"
MECHANICAL ROOF PART PLAN - DEMOLITION
2 SCALE: 1/4" = 1'-0"
MECHANICAL BELOW ROOF PART PLAN - DEMOLITION
SCALE: 1/4" = 1'-0"
RTU-1 DUCTWORK SECTION- DEMOLITION
S
S
S
(E) EXHAUST FAN
(E) EXHAUST FAN
(E) CONDENSING UNIT
(E) OUTSIDE AIR INTAKE HOOD
(E) OUTSIDE AIR INTAKE HOOD
(E) OUTSIDE AIR INTAKE HOOD
ROOF HATCH
(E)4" Ø V (E)4" Ø V
(E)4" Ø V
(E)3" Ø V
(E)4" Ø V
POWERED
EXAHUST
RTU-2
M101
(RL)RTU-1
2, 3
M101
1 2
NEW ROOF CURB
(E)3/4" Ø NG
(E)1" Ø CD
(RL)RTU-1
RTU-2 5
POWERED EXHAUST
OUTSIDE AIR HOOD
(E)3/4" Ø NG
(E)1" Ø CD
(RL)RTU-1
M101
CONNECT DUCTWORK TO
RTU-1 (ABOVE)
3(E)60"x18" - SA
60"x18" - RA
RELOCATED
DIFFUSER
(E)32"x20" - RA
12" Ø - RA
30"x18" - RA
60"x18" - RA
30"x16" - RA
(E)30"x14" - RA
RTU-1
(ABOVE)
(E )2
"x
R
A (E
)2 "x
R
A
(E)54"x16" - SA
RTU-2 (ABOVE),
NO HVAC WORK
BELOW ROOF
EXISTING
ROOF CURB
(ABOVE)
SHEET NOTES
1. PROVIDE NEW 14" HIGH ROOF CURB. NEW ROOF CURB TO BE SAME
WIDTH AS EXISTING CURB. LENGTH TO MATCH LENGTH OF UNIT.
2. REINSTALL RTU-1 ON NEW ROOF CURB. RECONNECT ELECTRICAL
DISCONNECT, POWER WIRING, CONTROL WIRING, NATURAL GAS
PIPING, CONDENSATE DRAIN, AND DUCTWORK. EXISTING SUPPLY AIR
TO REMAIN AS IS. RETURN AIR DUCT FROM BELOW TO BE NEW.
PROVDE NEW POWER RTU-1 POWERED EXHAUST UNIT TO MATCH
EXISTING.
3. PROVIDE NEW SMOKE DETECTOR IN RETURN AIR DUCTWORK AND A
NEW SMOKE DETECTOR IN SUPPLY AIR DUCTWORK, CONNECT TO
RE-INSTALLED RTU-1.
4. RELOCATE EXISTING CEILING DIFFUSER. COORDINATE WITH
EXISTING CEILING GRID.
5. PROVIDE NEW ROOFTOP UNIT, RTU-2. PROVIDE CURB ADAPTER IF
NECESSARY.
6. INSTALL RTU-2 ON EXISTING ROOF CURB. RECONNECT ELECTRICAL
DISCONNECT, POWER WIRING, CONTROL WIRING, NATURAL GAS
PIPING, CONDENSATE DRAIN, AND DUCTWORK. EXISTING SUPPLY AIR
AND RETURN AIR TO REMAIN AS IS.
7. PROVIDE NEW SMOKE DETECTORS IN EXISTING SUPPLY AND
RETURN DUCTWORK, EXISTING TO REMAIN. CONNECT NEW SMOKE
DETECTORS TO NEW RTU-2.
NEW DUCT SMOKE
DETECTOR
EXISTING CEILING
RE-INSTALL RTU-1
PROVIDE NEW
ROOF CURB
18"x60" - RA
(E)18"x60" - SA 1 "x
R
A
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9 /2
:0
:5
P
M
A u to d e s k D o c s /0
-M D
O T
M
V A
V
M
U L
/0
-0
M E
P C e n tr a l_ R
.r v t
M101
12/09/2022PWH
ATPWH 067196
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
PWH
ABOVE CEILING AND ROOF PLANS
MECHANICAL
P ro je c t N u m b e r:
SCALE: 3/32" = 1'-0"
MECHANICAL ROOF OVERALL PLAN - NEW WORK
SCALE: 1/4" = 1'-0"
MECHANICAL HVAC RTU-1 & RTU-2 PART PLAN - NEW WORK
SCALE: 1/4" = 1'-0"
MECHANICAL HVAC BELOW ROOF PART PLAN - NEW WORK
NO. DESCRIPTION DATE BY
SCALE: 1/4" = 1'-0"
RTU-1 DUCTWORK SECTION- NEW WORK
TYP
TYP AT CHANNEL WEB
C5x6.7 (TYP)
C5x6.7 (TYP)
JOIST OR
BEAM (TYP)
1/4" BENT PLATE TYP
FRAMING FOR HEADING
HEATING AND AC
AIR CONDITIONING UNITS
WIDTH OF
EQUIPMENT
EXISTING W16x40
STEEL BEAM
REMOVE DECKING AS
REQUIRED TO INSTALL
NEW RETURN AIR
DUCTWORK
REMOVE EXISTING STEEL SUPPORT
(UNDER EXISTING ROOF CURB)
EXISTING JOIST
EXISTING JOIST
DEMOLISH EXISTING RTU-1
ROOF CURB
L3x3x1/4
L4x3x3/16
L4x3x1/4
1'-0"
1'-2 1/2"
REMOVE AS REQUIRED
EXISTING JOIST
PROVIDE NEW STEEL SUPPORT
UNDER NEW ROOF CURB. REFER
TO "TYPICAL ROOFTOP ROOF
FRAMING DETAIL," THIS SHEET.
EXISTING JOIST
EXISTING W16x40
STEEL BEAM
NEW RTU-1 ROOF CURB
MODIFY AS PER DEMOLITION.
PROVIDE NEW STEEL AT END OF NEW CURB
PROVIDE NEW ROOF
SUPPORT MEMBERS ARE
PER DETAIL 3, THIS
SHEET
METAL DECK
PREFABRICATED ROOF CURB
INSULATION
COUNTERFLASHING
AIR CONDITIONING UNIT
PREFABRICATED CURB.
MOUNT ON TREX PLASTIC
NAILER
MEMBRANE ROOF
DUCT SUPPORT ALL AROUND.
FASTENED TO DECK & DUCT
M
IN
PIPING FROM MAIN
ISOLATION VALVE
(NON-LOCKING
TYPE)
DIRT LEG
PIPING TO GAS FIRED EQUIP. CONN.
UNION
GAS FIRED EQUIPMENT
MAX. 18" FLEXIBLE GAS PIPE (GAS
TITE "FLEX" OR APPROVED EQUAL)
6" LONG FULL SIZE
PIPE NIPPLE
PIPE CAP
REGULATOR VENT PIPES SHOULD BE RUN INDEPENDENTLY
OUT SIDEWALLS OF THE BUILDING.
M
IN
FLOOR/GRADE NOTE:
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/9 /2
:0
:5
P
M
A u to d e s k D o c s /0
-M D
O T
M
V A
V
M
U L
/0
-0
M E
P C e n tr a l_ R
.r v t
M501DETAILS AND SCHEDULES
12/09/2022PWH
ATPWH 067196
WALDORF BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
11 INDUSTRIAL PARK DRIVE, WALDORF, MD 20602
Pre-100% DESIGN SUBMISSION
PWH
MECHANICAL
P ro je c t N u m b e r:
SCALE: NTS
TYPICAL ROOFTOP ROOF FRAMING DETAIL
SCALE: NTS
BELOW ROOF SUPPORT STEEL DEMOLITION DETAIL
SCALE: NTS
BELOW ROOM SUPPORT STEEL NEW WORK DETAIL
SCALE: NTS
EQUIPMENT WITH DUCT PENETRATION ROOF CURB
4' 8'0'
SCALE: 1/4" = 1'-0"
NO. DESCRIPTION DATE BY
ROOFTOP UNIT SCHEDULE (GAS HEAT)
MARK
SUPPLY
AIRFLOW
(CFM)
SUPPLY
FAN ESP
(IN/WC)
SUPPLY
FAN (HP)
OUTSIDE
AIRFLOW
(CFM)
POWER
EXHAUST
FAN (HP)
DX COOLING
CAPACITY-TOTAL
(MBH)
DX COOLING
CAPACITY-SENSIBLE
(MBH)
DX COOLING COIL GAS HEAT ELECTRICAL DATA
DRIVE
APPROX.
OPERATING
WEIGHT (LBS)
BASIS OF DESIGN
REMARKS
EA DB
(F)
EA WB
(F)
LA DB
(F)
LA WB
(F)
EA DB
(F)
LA DB
(F)
INPUT
(MBH)
OUTPUT
(MBH) V Ø HZ MCA MOCP MANUFACTURER MODEL
(RL)RTU-1 10000 0.75 7.5 1200 0.00 289 231.4 80.0 67.0 58.9 57.9 60.0 78.8 320.0 256.0 208 3 60 123.0 150.0 DIRECT 2327 TRANE FOUNDATION GAC3300A3EMA 5
RTU-2 10000 0.75 4.7 1200 0.00 282.13 217.95 80.0 67.0 58.9 57.9 60.0 78.8 202.5 208 3 60 129.0 175.0 DIRECT 2417 TRANE PRECEDENT YSJ300 1, 2, 3, 4
1. PROVIDE MANUFACTURER'S ROOF CURB.
2. PROVIDE MANUFACTURER'S POWERED EXAHUST FAN OPTION. POWER EXAHUST SIZED PER MANUFACTURER RECOMMENDATIONS.
3. PROVIDE MANUFACTURER'S DISCONNECT.
4. RTU-2 TO HAVE (2) 4.5 HP SUPPLY FANS.
5. PEOVIDE NEW POWERED EXHAUST UNIT FOR RELOCATED RTU-1.
SCALE: NTS
NATURAL GAS CONNECTION TO EQUIPMENT PIPING