Attachment J-17 Air Source Inspection Forms.xlsx

XLSX spreadsheet 43 KB Posted

Attached to
Facilities And Operations Maintenance Support Services II (FOMSS II) Federal contract opportunity
Solicitation number
80MSFC25R0005
Issued by
National Aeronautics and Space Administration Marshall Space Flight Center

About this file

This file is an environmental inspection form listing air emission sources at various facilities, primarily focused on boilers, generators, and other air pollution sources. The spreadsheet catalogs equipment details including facility IDs, locations, manufacturer information, fuel types, heat input ratings, inspection frequencies, and installation dates.

The inventory includes significant and insignificant emission sources across multiple facilities (numbered 4200-4778), with detailed technical specifications for approximately 130 pieces of equipment. Major categories include surface coating operations, bulk gasoline storage, boilers (both gas-fired and electric), emergency generators (both IIII Compression Ignition and ZZZZ Existing types), and test areas. The document appears to be used for environmental compliance and inspection tracking, with equipment status noted as either "Active" or "Removed" and inspection frequencies listed as either "Annual" or "Semi-Annual."

View the file

Other files for this federal contract opportunity

Other files attached to Facilities And Operations Maintenance Support Services II (FOMSS II), newest first.
File Type Posted
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00003.docx DOCX document
80MSFC25R0005 SF30_Amendment P00003.PDF PDF
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00002.docx DOCX document
80MSFC25R0005 SF30_Amendment P00002.pdf PDF
Attachment J-3 Part 2 Collective Bargaining Agreements_Amendment P00002.pdf PDF
Attachment L-1 Excel Pricing Model (EPM)_FOMSS II Amendment P00002.xlsx XLSX spreadsheet
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00001.docx DOCX document
Attachment L-1 Excel Pricing Model (EPM)_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-3 Part 2 - Collective Bargaining Agreements_FOMSS II Amendment P00001.pdf PDF
80MSFC25R0005 SF 30_Amendment P00001.pdf PDF
Attachment J-17 Air Source Inspection Forms_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-16 Preventive Maintenance_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-3 Part 2 - Collective Bargaining Agreements.pdf PDF
80MSFC25R0005 FOMSS II Request for Proposal.docx DOCX document
Attachment J-9 Collateral Equipment Listing.xlsx XLSX spreadsheet
FOMSS II RFP SF1449.pdf PDF
Attachment J-20 Groundwater Treatment System Operations and Maintenance Manual.pdf PDF
Attachment J-16 Preventive Maintenance.xlsx XLSX spreadsheet
Attachment L-1 Excel Pricing Model (EPM).xlsx XLSX spreadsheet
Attachment L-3A Environmental Standard Operating Procedures.pdf PDF
Attachment J-11 Boilers.xlsx XLSX spreadsheet
Attachment L-3 Historical Data.xlsx XLSX spreadsheet
Attachment J-18 Snow and Ice Removal.pdf PDF
Attachment J-12 Tritium Exit Signs.xlsx XLSX spreadsheet
Attachment J-10 Lifting Devices.xlsx XLSX spreadsheet
Attachment J-19 MSFC Technical Specifications for Repairs and Construction.pdf PDF
Attachment J-6-A Installation-Accountable Government Property List.xlsx XLSX spreadsheet
Attachment J-14 Equipment Rooms Listing.xlsx XLSX spreadsheet
Attachment J-6-B Government Furnished Property List.xlsx XLSX spreadsheet
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALL

Air CategoryItemEnvioronmental IDFacility's IDLocationCategorySource TypeManufacturerPrimary FuelSecondary FuelHeat InputKilowattsHorsepowerSerial #Model #Inspection FrequencyAssest NumberInstall Date
(mmBtu)
SignificantSurface Coating4765-SOFI4765Sofi BoothActiveSemi-Annual
SignificantSurface Coating4602-1111-014602Paint Booth - FiltersActiveSemi-Annual
SignificantSurface Coating4650-PB-014650Paint - Water CurtainSemi-Annual
SignificantSurface Coating4707-130-014707Paint Booth - FiltersRemoved
SignificantSurface Coating4707-SOFI4707Sofi BoothActive
SignificantSurface Coating4707-PAINT4707Paint Booth - FiltersActive
SignificantBulk Gasoline Plant4611-1461120000 Gal Gasoline TankActive
SignificantGasoline Dispensing4611-E85461112000 Gal Gasoline TankActive
SignificantBoilers4200-BLR00014200Small Natural Gas BoilerRemovednatural gas6
SignificantBoilers4200-BLR-00024200Small Natural Gas BoilerRemovednatural gas6
InsignificantBoilers4207-BLR00024207-BLR00024207, Rm 127/E-03 S Wall W UnitSmall Natural Gas BoilerActiveLOCHINVARnatural gas0.51820 110385067KBN501Annual000529537/24/19
InsignificantBoilers4207-BLR00034207-BLR00034207, Rm 127/E-03 S Wall E UnitSmall Natural Gas BoilerActiveLOCHINVARnatural gas0.51820 110385065KBN501Annual000529547/24/19
SignificantBoilers4207-BLR0014207-BLR00044207, Rm B2/E-01 W Wall S UnitSmall Natural Gas BoilerActiveLOCHINVARnatural gas21820 110339087FBD2001Semi-Annual000529557/24/19
SignificantBoilers4207-BLR0024207-BLR00054207, Rm B2/E-01 W Wall N UnitSmall Natural Gas BoilerActiveLOCHINVARnatural gas21820 110339088FBD2001Semi-Annual000529567/24/19
SignificantBoilers4209-014209-BLR00014209, Boiler Rm 1 N UnitHot Water BoilerActiveYORK-SHIPLEY GLOBAL (AESYS)propane2.1445003-21449554L-H3W-50-W125 FAB.347656Semi-Annual000115841/1/04
SignificantBoilers4209-024209-BLR00024209, Boiler Rm 1 S UnitHot Water BoilerActiveYORK-SHIPLEY GLOBAL (AESYS)propane2.1445003-21448554L-H3W-50-W125 FAB.347656Semi-Annual000115851/1/04
InsignificantBoilers4241-BLR00014241-BLR00014241, Rm B100 N Unit (B-1)Boiler, Natural Gas FiredActiveLOCHINVARnatural gas0.61821 110479787KBN601Annual00052254
InsignificantBoilers4241-BLR00024241-BLR00024241, Rm B100 S Unit (B-2)Boiler, Natural Gas FiredActiveLOCHINVARnatural gas0.61821 110479786KBN601Annual00052255
InsignificantBoilers4249-BLR00014249-BLR00014249, Rm 127/E-02 N UnitBoiler, Natural Gas FiredActiveLOCHINVARnatural gas0.71819 110249726KBN701Annual000522876/26/19
InsignificantBoilers4249-BLR00024249-BLR00024249, Rm 127/E-02 S UnitBoiler, Natural Gas FiredActiveLOCHINVARnatural gas0.71819 110249725KBN701Annual000522886/26/19
InsignificantBoilers4250-BLR00014250-BLR00014250, Rm 19/E-02 N Unit (B-1)Boiler, Natural Gas-Fired, Hot WaterActiveLOCHINVARnatural gas0.71809 109368884KBN701Annual0005238710/16/18
InsignificantBoilers4250-BLR00014250-BLR00024250, Rm 19/E-02 S Unit (B-1)Boiler, Natural Gas-Fired, Hot WaterActiveLOCHINVARnatural gas0.71809 109368885KBN701Annual0005238810/16/18
InsignificantBoilers4260-BLR00014260, Mech Rm 162 NE CornerHot Water Boiler, Gas-FiredActiveLOCHINVARnatural gasF14H10286148KBN400Annual000441365/9/16
InsignificantBoilers4315-BLR00014315, Rm 105/E-01 N Unit (HWHD0002), Assoc.w/ ShowersBoiler, Hot WaterActiveLOCHINVAR0.8A15H20328959AWN801PMAnnual000448967/1/16
InsignificantBoilers4315-BLR00024315. Rm 105/E-01 S Unit (HWHD0003), Assoc. w/ ShowersBoiler, Hot WaterActiveLOCHINVAR0.8A15H20328958AWM801PMAnnual000448977/1/16
InsignificantBoilers4464-BLR00014464, Rm 120/E-01Boiler, Gas FiredActiveLOCHINVARnatural gas0.4901921 114986664FTX400NAnnual0005449510/17/19
InsignificantBoilers4464-BLR00024464, Rm 120/E-01Boiler, Gas FiredActiveLOCHINVARnatural gas0.4901921 114986663FTX400NAnnual0005449610/17/19
InsignificantBoilers4475-BLR00014475, Rm 143/E-01Boiler, Electric Hot WaterActiveLATTNER BOILER COMPANYelectric16.555663S165LW (Space Saver series)Annual000358737/2/12
InsignificantBoilers4476-BLR00014476, Rm 105/E-01 N Side E Unit (B-1)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51820 110339090FBN1501Annual0005246911/21/18
InsignificantBoilers4476-BLR00024476, Rm 105/E-01 N Side W Unit (B-2)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51820 110339089FBN1501Annual0005247011/21/18
SignificantBoilers4483-BLR00014483-BLR00014483, Rm 111Boiler, Gas FiredActiveLOCHINVARnatural gas4901921 114934914FBN4001Semi-Annual000545832/5/20
SignificantBoilers4483-BLR00024483-BLR00024483, Rm 111Boiler, Gas FiredActiveLOCHINVARnatural gas4901921 114934913FBN4001Semi-Annual000545842/5/20
InsignificantBoilers4485-BLR00014485, Rm 138/E-1Boiler, Gas FiredActiveLOCHINVARnatural gas0.6901921 114934878FTX600NAnnual0005177610/14/19
InsignificantBoilers4485-BLR00024485, Rm 138/E-1Boiler, Gas FiredActiveLOCHINVARnatural gas0.6901921 114934875FTX600NAnnual0005177710/14/19
InsignificantBoilers4487A-BLR00014487A-BLR00014487, Rm A0001/E-09A (B-1)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51818 110230975FBD1501Annual0005307010/29/18
InsignificantBoilers4487A-BLR00024487A-BLR00024487, Rm A0001/E-09A (B-2)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51818 110230977FBD1501Annual0005307110/29/18
InsignificantBoilers4487A-BLR00034487A-BLR00034487, Rm A0001/E-09A (B-3)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51818 110230978FBD1501Annual0005307210/29/18
SignificantBoilers4487AB-BLR00014487AB-BLR00014487, Rm AB0101 (B-3)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas2.51818 110249945FBD2500Semi-Annual0005305510/29/18
SignificantBoilers4487AB-BLR00024487AB-BLR00024487. Rm AB0101 (B-4)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas2.51818 110249944FBD2500Semi-Annual0005305610/29/18
InsignificantBoilers4487B-BLR00014487B-BLR00014487, Rm B0001/E-18A (B-5)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.251819 110250026FBD1251Annual0005308710/29/18
InsignificantBoilers4487B-BLR00024487B-BLR00024487, Rm B0001/E-18A (B-6)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.251819 110250027FBD1251Annual0005308810/29/18
InsignificantBoilers4487C-BLR00014487C-BLR00014487, Rm C178F (B-7)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.61811 109539625KBN601Annual0005302010/29/18
InsignificantBoilers4487C-BLR00024487C-BLR00024487, Rm C178F (B-8)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.61814 109843884KBN601Annual0005302110/29/18
InsignificantBoilers4487C-BLR00034487C-BLR00034487, Rm C157/E-54 (B-9)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51818 110230976FBD1501Annual0005302210/29/18
InsignificantBoilers4487C-BLR00044487C-BLR00044487, Rm C157/E-54 (B-10)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.51818 110230979FBD1501Annual0005302310/29/18
SignificantBoilers4491-EX-034491-BLR00014491, Rm 136/E-01, W UnitBoiler, Hot WaterActiveLOCHINVARnatural gas1.681921 114934870FTX500NSemi-Annual000544529/2/20
SignificantBoilers4491-BLR00024491 Rm 136/E-01, E UnitBoiler, Hot WaterActiveLOCHINVARnatural gas1.681921 114934869FTX500NSemi-Annual000544539/2/20
InsignificantBoilers4493-BLR00014493, Rm 155/E-04 N Wall N UnitBoiler, Gas FiredActiveLOCHINVARnatural gas0.51921 114934916FBN1001Annual000545102/11/21
InsignificantBoilers4493-BLR00024493, Rm 155/E-04 N Wall S UnitBoiler, Gas FiredActiveLOCHINVARnatural gas0.51921 115044521FBN1001Annual000545112/11/21
InsignificantBoilers4561-BLR00014561, Rm 104/E-01 NE WallElectric Hot Water BoilerActiveCLEAVER BROOKSelectric37T3018-1-3WB-210-360-160HWAnnual000372322/1/13
InsignificantBoilers4570-BLR00014570, Rm B55/E-1Electric Hot Water BoilerActiveVAPOR POWER INTERNATIONALelectric3423830HWR-2438-330-4CAnnual000372432/1/13
InsignificantBoilers4583-BLR00014583, Rm 154/E-2, CenterElectric Hot Water BoilerActiveVAPOR POWER INTERNATIONALelectric5223829HWR-2450-510-4CAnnual000372422/1/13
InsignificantBoilers4605-BLR00014605, Rm 31/E-01, SW CornerElectric BoilerActiveCLEAVER BROOKSelectric50EL002338HW202-195-150HW-480Annual000010921/1/02
SignificantBoilers4607A-BLR00014607A-BLR00014607, Rm 100 N UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.51914 114351546FBN3501Semi-Annual000525801/21/21
SignificantBoilers4607A-BLR00024607A-BLR00024607, Rm 100 N-Center UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.51906 113541792FBN3501Semi-Annual000525811/21/21
SignificantBoilers4607A-BLR00034607A-BLR00034607, Rm 100 S-Center UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.51921 114987051FBN3501Semi-Annual000525821/21/21
SignificantBoilers4607A-BLR00044607A-BLR00044607, Rm 100 S UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.51921 114987050FBN3501Semi-Annual000525831/21/21
SignificantBoilers4610-BLR0014610-BLR00014610, Rm B100/E-02 W End S UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas2.51820 110339076FBN2500Semi-Annual00052644
SignificantBoilers4610-BLR0024610-BLR00024610, Rm B100/E-02 W End S UnitBoiler, Natural Gas-FiredActiveLOCHINVARnatural gas2.51821 110416532FBN2500Semi-Annual00052645
SignificantBoilers4619-BLR0014619-BLR00014619. Rm 222/E-06Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas4.9992205 127989113FBN5001Semi-Annual00056157
SignificantBoilers4619-BLR0024619-BLR00024619, Rm 222/E-06Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas4.9992146 126918581FBN5001Semi-Annual00056158
InsignificantBoilers4649-BLR00014649, Rm 102/E-02Boiler, Electric Hot WaterActiveCLEAVER BROOKSelectric1.3513018-1-1WB-201-396-160HWAnnual000540871/1/14
SignificantBoilersPortable Boiler 14650-PBLR00014650, 4660 Yard, 200 HPSteam BoilerActiveCLEAVER BROOKSfuel/gas8.37200Semi-Annual000099311/1/99
SignificantBoilersPortable Boiler 24650-PBLR00024650, 4660 Yard, 100 HPSteam BoilerActivefuel oil4.185100Semi-Annual00002011
InsignificantBoilersPortable Boiler 34650-PBLR00034650, 4660 Yard, 50 HPSteam BoilerActivefuel/gas0.84100048945082Annual000100951/1/98
SignificantBoilersPortable Boiler 44650-PBLR00044650, 4660 Yard, 25 HPSteam BoilerActivefuel oil2.092257519Semi-Annual000100961/1/88
SignificantBoilers4650-BLR0014650A-BLR00014650A, Rm 100 E Unit (B-1)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas51831 111280907FBD5000Semi-Annual000520737/24/19
SignificantBoilers4650-BLR0024650A-BLR00024650A, Rm 100 Center Unit (B-2)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas51831 111280908FBD5000Semi-Annual000520747/24/19
SignificantBoilers4650-BLR0034650A-BLR00034650A, Rm 100 W Unit (B-3)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas51831 111280909FBD5000Semi-Annual000520757/24/19
InsignificantBoilers4653-BLR00014653, Rm 8/E-02 N CenterBoiler, ElectricActiveCLEAVER BROOKSelectric1.228T3018-1-2WB-201-360-160HWAnnual0003709912/1/12
SignificantBoilers4663-BLR0014663B-BLR00014663, Rm B010/E-01 W UnitBoiler, Natural Gas Fired Hot WaterActiveLOCHINVARnatural gas3.51820 110339165FBD3500Semi-Annual000503446/25/19
SignificantBoilers4663-BLR0024663B-BLR00024663, Rm B010/E-01 E UnitBoiler, Natural Gas Fired Hot WaterActiveLOCHINVARnatural gas3.51820 110339079FBD3500Semi-Annual000503456/25/19
InsignificantBoilers4666-BLR00014666, Mechanical Rm 2078 S WallBoiler, Electric Hot WaterActiveCLEAVER BROOKSelectric1.105T4015-1-1WB-201-324-160HWAnnual000416997/1/15
InsignificantBoilers4702-BLR00014702, Rm 116/E-02Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.6941921 114934878FTX600NAnnual00056159
InsignificantBoilers4702-BLR00024702, Rm 116/E-02Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.6941921 114934877FTX600NAnnual00056160
InsignificantBoilers4704-BLR00014704, Rm 105Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.851921 114987019FTX850NAnnual00056161
InsignificantBoilers4704-BLR00024704, Rm 105Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas0.851921 114987020FTX850NAnnual00056162
SignificantBoilers4705-BLR00014705-BLR00014705, Rm B0001/E-24Boiler, Gas FiredActiveLOCHINVARnatural gas6901921 114987046FBN6001Semi-Annual000546061/30/20
SignificantBoilers4705-BLR00024705-BLR00024705, Rm B0001/E-24Boiler, Gas FiredActiveLOCHINVARnatural gas6901921 114987045FBN6001Semi-Annual000546071/30/20
SignificantBoilers4705-BLR00034705-BLR00034705, Rm B119C/E-08Boiler, Gas FiredActiveLOCHINVARnatural gas2.5901921 114934926FBN2501Semi-Annual000546081/30/20
SignificantBoilers4705-BLR00044705-BLR00044705, Rm B119C/E-08Boiler, Gas FiredActiveLOCHINVARnatural gas2.5901921 114934927FBN2501Semi-Annual000546091/30/20
SignificantBoilers4707-BLR0024707-BLR00024707, Rm 126C (B-1)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.5941820 110339077FBD3500Semi-Annual000511894/25/19
SignificantBoilers4707-BLR0034707-BLR00034707, Rm 126C (B-2)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.5941820 110339078FBD3500Semi-Annual000511904/25/19
SignificantBoilers4707-BLR0044707-BLR00044707, Rm 126C (B-3)Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas3.5941820 110339166FBD3500Semi-Annual000511914/25/19
SignificantBoilers4708-B1B-074708-BLR00034708, Rm 1132E N UnitBoiler, Natural Gas FiredActiveLOCHINVARelectric390J12H00048648FBN3000Semi-Annual000398091/1/14
SignificantBoilers4708-B1B-084708-BLR00044708, Rm 1132E S UnitBoiler, Natural Gas FiredActiveLOCHINVARelectric390J12H00052559FBN3000Semi-Annual000398101/1/14
SignificantBoilers4708-B1B-054708-BLR00054708, Rm B1B/E-08, N UnitBoiler, Natural Gas FiredActiveLOCHINVARelectric2.5751746108178395FBN2500Semi-Annual000528141/1/18
SignificantBoilers4708-B1B-064708-BLR00064708, Rm B1B/E-08, S UnitBoiler, Natural Gas FiredActiveLOCHINVARelectric2.5751808 109284171FBN2500Semi-Annual000528151/1/18
SignificantBoilers4714-BLR00014714-BLR00014714, Rm 100/E-01 E UnitBoiler, Gas FiredActiveLOCHINVARnatural gas3901915 114440472FBN3001Semi-Annual000508771/1/20
SignificantBoilers4714-BLR00024714-BLR00024714, Rm 100/E-01 W UnitBoiler, Gas FiredActiveLOCHINVARnatural gas3901915 114440473FBN3001Semi-Annual000508781/1/20
SignificantBoilers4718-EX-014718-BLR00014718, Rm 115/E-1, East Wall - Disconnect at boilerSteam BoilerActiveCLEAVER BROOKSnatural gas5.1031000L104170CBI-700-125-015Semi-Annual000043861/1/04
InsignificantBoilers4723-BLR00014723, Boiler Rm 116ABoiler, Gas FiredActiveLOCHINVARnatural gas0.725221921 114987029FTX725NAnnual000514671/1/20
InsignificantBoilers4727-BLR00014727, Rm 116/E-02Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.251819 110250028FBD1251Annual000561636/1/20
InsignificantBoilers4735-BLR00014735. Rm 100Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.251921 114987052FBN1251Annual00056164
InsignificantBoilers4735-BLR00024735, Rm 100Boiler, Natural Gas-FiredActiveLOCHINVARnatural gas1.251919 114627427FBN1251Annual00056165
InsignificantBoilers4747-BLR00014747, Rm 112Boiler, Gas FiredActiveLOCHINVARnatural gas0.725221921 114987031FTX725NAnnual000514825/1/20
InsignificantBoilers4747-BLR00024747, Rm 112Boiler, Gas FiredActiveLOCHINVARnatural gas0.725221921 114987030FTX725NAnnual000514835/1/20
InsignificantBoilers4752-BLR00014752, Outside EastHot Water BoilerActiveFULTON BOILERSnatural gas381817PHW-1400Annual000311143/1/10
InsignificantBoilers4755-BLR00014755, Rm 119Hot Water BoilerActiveFULTON BOILERSnatural gas381847PHW-1400Annual0003045211/10/09
InsignificantBoilers4755-BLR00024755, Rm 119Hot Water BoilerActiveFULTON BOILERSnatural gas381818PHW-1400Annual0003045311/10/09
InsignificantBoilers4755-BLR00034755, Rm 119Hot Water BoilerActiveFULTON BOILERSnatural gas381859PHW-1400Annual0003045411/10/09
SignificantBoilers4765-BLR0014765A-BLR00014765A, Rm 100 E Unit (B-1)Boiler, Natural Gas-Fired SteamActiveSellers Manufacturing Co.natural gas3.711100105484A100HP-77C' S-SERIESSemi-Annual000524859/15/19
SignificantBoilers4765-BLR0024765A-BLR00024765A, Rm 100 W Unit (B-2)Boiler, Natural Gas-Fired SteamActiveSellers Manufacturing Co.natural gas3.711100105484B100HP-77C' S-SERIESSemi-Annual000524869/15/19
InsignificantBoilers4776-BLR00014776, Rm 104/E-01Steam BoilerOut of ServiceCLEAVER BROOKS376-07887-M3WTHP-7A-1250000042551/1/80
InsignificantBoilers4776-BLR00024776, Rm 104/E-01Boiler, Natural Gas-FiredActiveBRYAN BOILERSnatural gas1.5102786AB120-S-150-FDGAnnual00056166
InsignificantBoilers4776-BLR00034776, Rm 104/E-01Boiler, Natural Gas-FiredActiveBRYAN BOILERSnatural gas1.5102777AB120-S-150-FDGAnnual00056167

Significant Abrasive Blasting 4745 Sand Blasting Semi-Annual

Trivial Cleaning Operations PC-Fugitive PC-Fugitive Site-wide Annual

SignificantTest AreaRP-1Test AreaEngine TestingSemi-Annual
SignificantTest AreaSRMTest AreaEngine TestingSemi-Annual
SignificantTest AreaHPPTest AreaEngine TestingSemi-Annual
SignificantTest AreaRLFTest AreaEngine TestingSemi-Annual
SignificantGenerators4201-GEN0003REMOVED4201IIII Compression Ignition Emgcy Generator364
SignificantGenerators4208-GEN00014208-GEN00014208IIII Compression Ignition Emgcy Generator2921
SignificantGenerators4220-GEN00014220-GEN00014220IIII Compression Ignition Emgcy Generator230
SignificantGenerators4221-GEN00014221-GEN00014221IIII Compression Ignition Emgcy Generator463
SignificantGenerators4250-GEN00014250-GEN00014250IIII Compression Ignition Emgcy Generator80.4
SignificantGenerators4464-GEN000014464-GEN00014464IIII Compression Ignition Emgcy Generator49
SignificantGenerators4487-GEN00014487AB-GEN00014487IIII Compression Ignition Emgcy Generator158
SignificantGenerators4583-GEN00014583-GEN00014583IIII Compression Ignition Emgcy Generator197
SignificantGenerators4601-GEN00014601-GEN00014601IIII Compression Ignition Emgcy Generator27.1
SignificantGenerators4602-GEN00014602-GEN00014602IIII Compression Ignition Emgcy Generator635
SignificantGenerators4610-GEN00044610-GEN00044610IIII Compression Ignition Emgcy Generator241
SignificantGenerators4611-GEN00014611A-GEN00014611IIII Compression Ignition Emgcy Generator80
SignificantGenerators4650-GEN00014650-GEN00014650IIII Compression Ignition Emgcy Generator755
SignificantGenerators4651-GEN00014651-GEN00014651IIII Compression Ignition Emgcy Generator201
SignificantGenerators4666-GEN00014666-GEN00014666IIII Compression Ignition Emgcy Generator133
SignificantGenerators4674-GEN0001REMOVED4674IIII Compression Ignition Emgcy Generator198
SignificantGenerators4708-GEN00014708-GEN00014708IIII Compression Ignition Emgcy Generator1207
SignificantGenerators4711-GEN00014711-GEN00014711IIII Compression Ignition Emgcy Generator49
SignificantGenerators4755-GEN00014755-GEN00014755IIII Compression Ignition Emgcy Generator1194
SignificantGenerators4765-GEN00014765-GEN00014765IIII Compression Ignition Emgcy Generator48.8
SignificantGenerators4778-GEN00014778-GEN00014778IIII Compression Ignition Emgcy Generator80
SignificantGenerators4200-GEN0001REMOVED4200ZZZZ Existing Emgcy GeneratorDiesel449
SignificantGenerators4201-GEN0002REMOVED4201ZZZZ Existing Emgcy GeneratorDiesel140
SignificantGenerators4203-GEN00014203-GEN00014203ZZZZ Existing Emgcy GeneratorDiesel474
SignificantGenerators4209-GEN00014209-GEN00014209ZZZZ Existing Emgcy GeneratorDiesel764
SignificantGenerators4249-GEN00014249-GEN00014249ZZZZ Existing Emgcy GeneratorDiesel435
SignificantGenerators4312-GEN00014312-GEN00014312ZZZZ Existing Emgcy GeneratorDiesel169
SignificantGenerators4436-GEN00014436-GEN00014436ZZZZ Existing Emgcy GeneratorDiesel352
SignificantGenerators4475-GEN00014475-GEN00014475ZZZZ Existing Emgcy GeneratorDiesel750
SignificantGenerators4476-GEN00014476-GEN00014476ZZZZ Existing Emgcy GeneratorDiesel43.7
SignificantGenerators4487C-GEN00014487C-GEN00014487ZZZZ Existing Emgcy GeneratorDiesel680
SignificantGenerators4493-GEN00014493A-GEN00014493ZZZZ Existing Emgcy GeneratorDiesel660
SignificantGenerators4600-GEN00014600-GEN00014600ZZZZ Existing Emgcy GeneratorDiesel37.1
SignificantGenerators4605-GEN00014605-GEN00014605ZZZZ Existing Emgcy GeneratorPropane87
SignificantGenerators4619-GEN00014619-GEN00014619ZZZZ Existing Emgcy GeneratorDiesel160
SignificantGenerators4629-GEN00014644-GEN00014629ZZZZ Existing Emgcy GeneratorDiesel605
SignificantGenerators4649-GEN00014649-GEN00014649ZZZZ Existing Emgcy GeneratorDiesel221
SignificantGenerators4649-GEN00024649-GEN00024649ZZZZ Existing Emgcy GeneratorDiesel202
SignificantGenerators4663-GEN00014663-GEN00014663ZZZZ Existing Emgcy GeneratorDiesel765
SignificantGenerators4663-GEN00024663-GEN00024663ZZZZ Existing Emgcy GeneratorDiesel1106
SignificantGenerators4663-GEN00034663-GEN00034663ZZZZ Existing Emgcy GeneratorDiesel2847
SignificantGenerators4663-GEN00044663-GEN00044663ZZZZ Existing Emgcy GeneratorDiesel2520
SignificantGenerators4663-GEN00054663-GEN00054663ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-01REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-02REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-03REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-04REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-05REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-06REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-07REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-08REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-09REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-10REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-11REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-12REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4667-999-13REMOVED4667ZZZZ Existing Emgcy GeneratorDiesel2577
SignificantGenerators4692-GEN00014692-GEN00014692ZZZZ Existing Emgcy GeneratorDiesel65
SignificantGenerators4707-GEN00014707-GEN00014707ZZZZ Existing Emgcy GeneratorDiesel765
SignificantGenerators4708-GEN00024708-GEN00024708ZZZZ Existing Emgcy GeneratorDiesel1199
SignificantGenerators4718-3-GEN00014718-3-GEN00014718ZZZZ Existing Emgcy GeneratorDiesel600
SignificantGenerators4718-GEN00024718-GEN00024718ZZZZ Existing Emgcy GeneratorDiesel880
SignificantGenerators4755-GEN00024755-GEN00024755ZZZZ Existing Emgcy GeneratorDiesel299
SignificantGenerators4761-GEN00014761-GEN00014761ZZZZ Existing Emgcy GeneratorDiesel109
SignificantGenerators4708-GEN003NA4708Emgcy Generator
SignificantGenerators4630-GEN001NA4630Emgcy Generator
InsignificantTest AreaSite WideSite WideCombustion Equipment
InsignificantTest AreaSite WideSite WideCombustion Equipment
InsignificantGeneratorsEast Test AreaCombustion Equipment, Portable Generator, MFG: Davey, ECN#065836
InsignificantGenerators4200-E1-01REMOVED4200Combustion Equipment, Emgcy Generator300
InsignificantGenerators4202-E1-014202Combustion Equipment, Emgcy Generator158
InsignificantGenerators4203-EX-014203Combustion Equipment, Emgcy Generator275
InsignificantBoilers4207-E3REMOVED4207Combustion Equipment, Hot Water HeaterGENERACDiesel<1.6 MMBTU/hr
InsignificantGenerators42094209Combustion Equipment, Emgcy Generator
InsignificantTanks42094209Diesel Storage Tanks, 2500 gal.
InsignificantGenerators4249-GEN00014612Combustion Equipment, Emgcy Generator275
InsignificantGenerators4312-EX-024312Combustion Equipment, Emgcy Generator100
InsignificantGenerators44364436Combustion Equipment, Emgcy Generator20
InsignificantGenerators44644464Combustion Equipment, Emgcy Generator
InsignificantGenerators4470-EX-014470-GEN00014470Combustion Equipment, Emgcy Generator17.5
InsignificantGenerators44754475Combustion Equipment, Emgcy Generator450
InsignificantGenerators44764476Combustion Equipment, Emgcy Generator
InsignificantGenerators4482-EX-01REMOVED4482Combustion Equipment, Emgcy Generator5
InsignificantGenerators4487-EX-034487Combustion Equipment, Emgcy Generator470
InsignificantGenerators44934493ACombustion Equipment, Emgcy Generator400
InsignificantEngine45234523Combustion Equipment, Limited Use Internal Combustion Diesel EngineDiesel465
InsignificantGenerators4596 Port 14596Combustion Equipment,Portable Generator (Welding Machine) MFG: Miller, ECN: 185634
InsignificantGenerators4596 Port 104555Combustion Equipment, Portable Generator, MFG: Magnetek Inc Allis Dv F-Allis, ECN:1535073
InsignificantGenerators4596 Port 114555Combustion Equipment, Portable Generator, MFG: Magnetek Inc Allis Dv F-Allis, ECN:1535072
InsignificantGenerators4596 Port 24596Combustion Equipment, Portable Generator (Welding Machine) MFG: Miller, ECN: 0625631
InsignificantGenerators4596 Port 34596Combustion Equipment, Portable Generator (Welding Machine) MFG: Miller, ECN: 0836106
InsignificantGenerators4596 Port 44596Combustion Equipment, Portable Generator (Welding Machine) MFG: Hobart Brothers, ECN: 2196293
InsignificantGenerators4596 Port 54596Combustion Equipment, Portable Generator (Light Unit), MFG: Allmand Brothers, ECN:2015936
InsignificantGenerators4596 Port 64596Combustion Equipment, Portable Generator (Welding Machine) MFG: Miller, ECN: 219624286
InsignificantGenerators4596 Port 74596Combustion Equipment, Portable Generator, MFG: Onan, ECN:1895377
InsignificantGenerators4596 Port 84596Combustion Equipment, Portable Generator (Welding Machine) MFG: Miller, ECN: 100435
InsignificantGenerators4596 Port 94596Combustion Equipment, Portable Generator (Welding Machine), ECN: 625631, MSFC#114613
InsignificantGenerators46004600Combustion Equipment, Emgcy Generator11.5
InsignificantGenerators4605-EX-014605Combustion Equipment, Emgcy Generator45
InsignificantGenerators4610-EX-014610-GEN00014610Combustion Equipment, Emgcy Generator600
InsignificantGenerators4619-EX-014619-GEN00024619Combustion Equipment, Emgcy Generator - 4619-GEN0001105
InsignificantGenerators46294629Combustion Equipment, Emgcy Generator400
InsignificantGenerators4649-14649Combustion Equipment, Emgcy Generator135
InsignificantGenerators4649-24649Combustion Equipment, Emgcy Generator15
InsignificantGenerators4650 PGEN124650Combustion Equipment, Portable Generator, MFG: Dayton11
InsignificantGenerators4650 PGEN64650Combustion Equipment, Portable Generator, MFG: Onan, ECN:2194444
InsignificantGenerators4650 PGEN74650Combustion Equipment, Portable Generator, MFG: Onan, ECN:2194445
InsignificantGenerators4650 PGEN84650Combustion Equipment, Portable Generator, MFG: Dayton
InsignificantGenerators4663-EX-014663Combustion Equipment, Emgcy Generator - 4663-GEN0001765
InsignificantGenerators4663-EX-034663Combustion Equipment, Emgcy Generator - 4663-GEN00031106
InsignificantGenerators4663-EX-054663Combustion Equipment, Emgcy Generator - 4663-GEN0002765
InsignificantGenerators4663-EX-074663Combustion Equipment, Emgcy Generator - 4663-GEN0004847
InsignificantGenerators4663-EX-084663Combustion Equipment, Emgcy Generator - 4663-GEN00052520
InsignificantGenerators4674-EX-01REMOVED4674Combustion Equipment, Emgcy Generator - 4674-GEN00014674
InsignificantGenerators4692-EX-01REMOVED4692Combustion Equipment, Emgcy Generator - 4692-GEN000120
InsignificantGenerators4705-EX-014705-GEN00014705Combustion Equipment, Emgcy Generator (OOS)
InsignificantGenerators4707REMOVED4707Combustion Equipment, Emgcy Generator - 4707-GEN0001500
InsignificantGenerators4708-E15-024708Combustion Equipment, Emgcy Generator - 4708-GEN00021199
InsignificantGenerators47184718Combustion Equipment, Emgcy Generator - 4718-GEN0002800
InsignificantGenerators4718-34718-3Combustion Equipment, Emgcy Generator - 4718-3-GEN0001600
InsignificantBoilers47524752Combustion Equipment, Natural Gas Boiler1.4 MMBTU/hr
InsignificantBoilers47554755Combustion Equipment, 3 Natural Gas Boilers(3) 1.4 MMBTU/hr
InsignificantGenerators4755REMOVED4755Combustion Equipment, Emgcy Generator - 4755-GEN0001800
InsignificantGenerators4755-EX-03REMOVED4755Combustion Equipment, Emgcy Generator - 4755-GEN00021196
InsignificantGenerators4761-E2-024761Combustion Equipment, Emgcy Generator
InsignificantGeneratorsM-1 PGEN1M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Kohler, PGEN1330
InsignificantGeneratorsM-1 PGEN11M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Onan750
InsignificantGeneratorsM-1 PGEN13M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Generac, ECN#3052125, GPE0294, PGEN13100
InsignificantGeneratorsM-1 PGEN14M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Onan, came from 431266
InsignificantGeneratorsM-1 PGEN2M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Generac, PGEN250
InsignificantGeneratorsM-1 PGEN3M1YARDM-1 YardCombustion Equipment, Portable Generator, MFG: Generac, PGEN315
InsignificantGeneratorsM-1 PGEN4658M1YARD4658 (not connected)Combustion Equipment, Portable Generator, came from 4566
InsignificantGeneratorsT4728T4728-GEN00014728Combustion Equipment, Emgcy Generator (on a portable trailer near hitch)

ADD ROW

&"Times New Roman,Regular"&12Attachment J-17: Air Source Inspection Forms

&"Times New Roman,Regular"&12J-17-&P

Sheet1

<.5 mmbtu & definition
.5-1.59 = insig + definition
1.6-5.99 sig + definitino + 5yr tune up
6-9.99 + defition + 2yr tunr up
10+ defitino + 1yr tune up

DATA TABLES

Boilers
Generators
Parts Washers
Test Area
Tanks
Skeet Range
Pistol Range
Engine
Surface Coating
Abrasive Blasting
Cleaning Operations
Bulk Gasoline Plant
Gasoline Dispensing
Flare Stacks
Inspection Frquency
ADD ROW
SignificantSemi-Annual
InsignificantAnnual
TrivialAnnual

Source Type

Active
Removed
Not Used, Storage
Out of Service

File details come from the government source that posted it. Updated .