Attachment J-11 Boilers.xlsx

XLSX spreadsheet 23 KB Posted

Attached to
Facilities And Operations Maintenance Support Services II (FOMSS II)
Solicitation number
80MSFC25R0005
Issued by

About this file

This file is Attachment J-11, which contains a detailed inventory listing of 92 boilers (86 hot water and 6 steam) at various facilities, including their location codes, NBS numbers, serial numbers, and last inspection dates. The spreadsheet tracks inspection dates ranging from April 2022 to October 2023, with specific notations for boiler manufacturers including Lockinvar and CleaverBrooks.

The inventory includes operational status notes for several units, with four boilers specifically marked as out of service or never installed: one tagged out due to a bad blower motor (4650-PBLR0001), one tagged out of service (4650-PBLR0004), one taken out of service (4752-BLR0001), and three never installed units in storage (4760-BLR0001, 4760-BLR0002, and 4760-BLR0003). This document appears to be a supporting attachment for the NASA Marshall Space Flight Center's Facilities and Operations Maintenance Support Services II (FOMSS II) solicitation.

View the file

Other files

File Type Posted
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00003.docx DOCX document
80MSFC25R0005 SF30_Amendment P00003.PDF PDF
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00002.docx DOCX document
80MSFC25R0005 SF30_Amendment P00002.pdf PDF
Attachment J-3 Part 2 Collective Bargaining Agreements_Amendment P00002.pdf PDF
Attachment L-1 Excel Pricing Model (EPM)_FOMSS II Amendment P00002.xlsx XLSX spreadsheet
80MSFC25R0005 FOMSS II Request for Proposal_Amendment P00001.docx DOCX document
Attachment L-1 Excel Pricing Model (EPM)_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-3 Part 2 - Collective Bargaining Agreements_FOMSS II Amendment P00001.pdf PDF
80MSFC25R0005 SF 30_Amendment P00001.pdf PDF
Attachment J-17 Air Source Inspection Forms_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-16 Preventive Maintenance_FOMSS II Amendment P00001.xlsx XLSX spreadsheet
Attachment J-3 Part 2 - Collective Bargaining Agreements.pdf PDF
80MSFC25R0005 FOMSS II Request for Proposal.docx DOCX document
Attachment J-9 Collateral Equipment Listing.xlsx XLSX spreadsheet
FOMSS II RFP SF1449.pdf PDF
Attachment J-20 Groundwater Treatment System Operations and Maintenance Manual.pdf PDF
Attachment J-16 Preventive Maintenance.xlsx XLSX spreadsheet
Attachment L-1 Excel Pricing Model (EPM).xlsx XLSX spreadsheet
Attachment L-3A Environmental Standard Operating Procedures.pdf PDF
Attachment J-17 Air Source Inspection Forms.xlsx XLSX spreadsheet
Attachment L-3 Historical Data.xlsx XLSX spreadsheet
Attachment J-18 Snow and Ice Removal.pdf PDF
Attachment J-12 Tritium Exit Signs.xlsx XLSX spreadsheet
Attachment J-10 Lifting Devices.xlsx XLSX spreadsheet
Attachment J-19 MSFC Technical Specifications for Repairs and Construction.pdf PDF
Attachment J-6-A Installation-Accountable Government Property List.xlsx XLSX spreadsheet
Attachment J-14 Equipment Rooms Listing.xlsx XLSX spreadsheet
Attachment J-6-B Government Furnished Property List.xlsx XLSX spreadsheet
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Boilers

LocationNBS NumberSerial NumberNotesLast Inspection Date92 Total Boilers 86 Hot Water 6 Steam
4650-PBLR000211602OL1016023/23/23
4650-PBLR000311242L1063639/26/23
4765A-BLR000112835105484A3/14/23
4765A-BLR000212842105484B3/23/23
4776-BLR0002621651027779/20/23
4776-BLR0003621741027869/20/23
4207-BLR00024282411.18.14.0010310/4/23
4207-BLR00034282251.18.14.000874/22/22
4207-BLR0004318019183180194/5/23Lockinvar
4207-BLR0005318314183183144/5/23Lockinvar
4209-BLR00012878103-214499/20/23
4209-BLR00022878003-214483/23/23
4241-BLR0001428204D1.18.14.000663/28/23
4241-BLR0002428206D1.18.14.000683/28/23
4249-BLR0001426009D1.18.08.000373/28/23
4249-BLR0002426010D1.18.08.000383/28/23
4250-BLR0001421653D1.17.50.001843/28/23
4250-BLR0002421666D1.17.50.001973/28/23
4260-BLR0001286148D1.13.44.007424/5/23
4315-BLR0001328959D1.14.43.009884/5/23
4315-BLR0002328958D1.14.43.009874/5/23
4464-BLR00019955719.PGT400.113.00123/28/23
4464-BLR00029884719.PGT400.113.00083/28/23
4475-BLR000155663942364/22/22
4476-BLR00013199881103390909/20/23
4476-BLR00023199871103390899/20/23
4483-BLR000133877911493491410/4/23
4483-BLR00023395201149349134/22/22
4485-BLR000124579817.PGT550.112.00264/5/23
4485-BLR000210021019.PGT550.112.01294/5/23
4487A-BLR0001319740183197403/23/23Lockinvar
4487A-BLR0002319741183197413/23/23Lockinvar
4487A-BLR0003319742183197423/23/23Lockinvar
4487AB-BLR0001321526183215263/23/23Lockinvar
4487AB-BLR0002321522183215223/23/23Lockinvar
4487B-BLR0001319428183194283/23/23Lockinvar
4487B-BLR0002319427183194273/23/23Lockinvar
4487C-BLR0001422735D1.18.01.000713/23/23
4487C-BLR0002425554D1.18.06.005003/23/23
4487C-BLR000331973911023097610/4/23
4487C-BLR000431974311023097910/4/23
4491-BLR00011010731149348704/22/22
4491-BLR00021010741149348694/22/22
4493-BLR0001339750193397504/5/23Lockinvar
4493-BLR0002339482193394824/22/22Lockinvar
4561-BLR000117749T3018-1-34/5/23CleaverBrooks
4570-BLR000110486238304/5/23
4583-BLR000110485238294/5/23
4605-BLR000113243c233810/4/23
4607A-BLR0001337011193370113/23/23Lockinvar
4607A-BLR0002335097193350973/23/23Lockinvar
4607A-BLR00033395181933951810/4/23Lockinvar
4607A-BLR00043392531933925310/4/23Lockinvar
4610-BLR0001321894183218943/28/23Lockinvar
4610-BLR00023218961832189610/4/23Lockinvar
4619-BLR00013783792137837910/4/23Lockinvar
4619-BLR00023815242238152410/4/23Lockinvar
4649-BLR000117735T3018-1-13/28/23CleaverBrooks
4650A-BLR0001325094183250944/5/23Lockinvar
4650A-BLR0002325093183250934/5/23Lockinvar
4650A-BLR0003325095183250954/5/23Lockinvar
4653-BLR000117742T3018-1-23/28/23CleaverBrooks
4663B-BLR0001322480183224803/28/23Lockinvar
4663B-BLR0002321905183219053/28/23Lockinvar
4666-BLR000118683T4015-1-110/4/23CleaverBrooks
4702-BLR0001288503114938779/26/23
4702-BLR00021002171002179/26/23
4704-BLR00011050371149870199/26/23
4704-BLR00021029721149870209/26/23
4705-BLR0001340086193400864/5/23Lockinvar
4705-BLR0002338039193380394/5/23Lockinvar
4705-BLR0003339244193392444/22/22Lockinvar
4705-BLR0004339246193392464/22/22Lockinvar
4707-BLR0002321907183219079/26/23Lockinvar
4707-BLR0003322163183221639/26/23Lockinvar
4707-BLR0004322479183224799/26/23Lockinvar
4708-BLR000348648J12H000486489/26/23
4708-BLR000452559J12H000525599/26/23
4708-BLR00053146733146739/26/23
4708-BLR00063185573185579/26/23
4714-BLR00013380291144404729/26/23
4714-BLR00023383851144404739/26/23
4718-BLR000113480OL1041709/26/23
4723-BLR000199545995454/22/22
4727-BLR0001318890183188904/22/22Lockinvar
4735-BLR0001339224193392244/5/23Lockinvar
4735-BLR0002336163193361634/5/23Lockinvar
4747-BLR00019954719.PGT700.141.00144/5/23
4747-BLR00029962019.PGT700.141.00214/5/23
4755-BLR00011847F1063211A10/4/23
4755-BLR0002181818184/22/22
4755-BLR00031859185910/4/23
4650-PBLR0004N/AN/ABoiler is tagged out of service.N/A
4650-PBLR000112158OL102455Boiler is tagged out of service. Bad blower motor.3/23/23
4656-BLR0001N/AN/ANever installedN/A
4752-BLR0001N/AN/ABoiler taken out of service.N/A
4760-BLR0001N/AN/ANever installed - In storageN/A
4760-BLR0002N/AN/ANever installed - In storageN/A
4760-BLR0003N/AN/ANever installed - In storageN/A
N/A

&"Times New Roman,Bold"&12Attachment J-11 Boilers

&"Times New Roman,Regular"&12J-11-&P

File details come from the government source that posted it. Updated .