This document is Attachment I from the Colorado Office of Information Technology (OIT) Request for Proposal (RFP), providing detailed guidelines for deliverables in a broadband telecommunications service contract. The attachment serves as a comprehensive example template illustrating the extensive documentation required for three different network connectivity scenarios: fiber optic installation, wireless solution, and cellular tower location. For each scenario, the document outlines specific requirements including location details, circuit types, bandwidth specifications, equipment listings, last-mile connectivity information, path diversity solutions, circuit diagrams, and provider information.
The examples are designed to help vendors understand the precise level of detail expected in their proposals, with each scenario including specific acceptance criteria such as equipment completeness, specification accuracy, model number verification, provider reputation, timeline realism, and cost transparency. The document emphasizes that these examples are not exhaustive but serve as a guide, encouraging vendors to provide comprehensive documentation that allows OIT to fully evaluate proposed solutions. The goal is to ensure that the selected vendor can effectively manage and optimize the State of Colorado's broadband telecommunications infrastructure with detailed, verifiable information about network connectivity, equipment, providers, and service level agreements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment I: Examples of Detailed Deliverables
This appendix provides examples of the expected documentation for various scenarios to illustrate the level of detail required in the "Detailed Deliverables Specific to Each
Location" deliverable.
Example 1: Fiber Optic Installation
● Location: [Specific address of the State office]
● Circuit Type: Dedicated fiber optic internet access
● Bandwidth: 1 Gbps symmetrical
● Equipment:
○ [List of equipment required for installation, e.g., fiber optic modem, router, firewall]
○ Include model numbers and specifications for each piece of equipment.
○ Acceptance Criteria:
■ Equipment list is complete and includes all necessary components.
■ Specifications are accurate and meet the requirements outlined in the RFP.
■ Model numbers are valid and verifiable.
● Last-Mile Connectivity:
○ Technology: Fiber optic cable
○ Provider: [Name of the Last-Mile provider]
○ Installation Timeline: [Estimated timeline for installation, including any potential delays]
○ Costs: [Detailed breakdown of costs associated with Last-Mile connectivity, including installation, materials, and recurring fees]
○ Acceptance Criteria:
■ Technology is as specified and appropriate for the location.
■ Provider is a reputable and reliable company.
■ Timeline is realistic and includes key milestones.
■ Cost breakdown is transparent and accurate.
● Path Diversity:
○ Describe the path diversity solution implemented to ensure redundancy
(e.g., diverse fiber routes, redundant equipment).
○ Include a diagram illustrating the path diversity.
○ Acceptance Criteria:
■ Description clearly explains the path diversity solution.
■ Diagram accurately illustrates the diverse paths.
■ Solution provides adequate redundancy as defined by OIT.
● Circuit Diagram:
○ Provide a detailed circuit diagram illustrating the network connectivity, including the location of the State office, the Last-Mile provider's network, and any intermediate points.
○ Acceptance Criteria:
■ Diagram is detailed and accurate.
■ All network components and connections are clearly labeled.
■ The diagram includes the OIT network as well as the provider network.
● Last-Mile Provider Information:
○ Include contact information for the Last-Mile provider.
○ Specify the service level agreement (SLA) with the provider, including guaranteed uptime and response times.
○ Acceptance Criteria:
■ Contact information is complete and accurate.
■ SLA meets or exceeds the minimum requirements outlined in the
RFP.
Example 2: Wireless Solution
● Location: [Specific address of the State office]
● Circuit Type: Fixed wireless internet access
● Bandwidth: 100 Mbps symmetrical
○ [List of equipment required for installation, e.g., wireless antenna, modem, router]
○ Include model numbers and specifications for each piece of equipment.
○ Acceptance Criteria:
■ Equipment list is complete and includes all necessary components.
■ Specifications are accurate and meet the requirements outlined in the RFP.
● Last-Mile Connectivity:
○ Technology: Fixed wireless
○ Provider: [Name of the Last-Mile provider]
○ Installation Timeline: [Estimated timeline for installation, including any potential delays]
○ Costs: [Detailed breakdown of costs associated with Last-Mile connectivity, including installation, equipment, and recurring fees]
○ Acceptance Criteria:
■ Technology is as specified and appropriate for the location.
■ Provider is a reputable and reliable company.
■ Timeline is realistic and includes key milestones.
■ Cost breakdown is transparent and accurate.
● Path Diversity:
○ Describe the path diversity solution implemented (e.g., redundant wireless links, backup cellular connection).
○ Include a diagram illustrating the path diversity.
○ Acceptance Criteria:
■ Description clearly explains the path diversity solution.
■ Diagram accurately illustrates the diverse paths.
■ Solution provides adequate redundancy as defined by OIT.
including the location of the State office, the wireless tower, and any intermediate points.
○ Acceptance Criteria:
■ Diagram is detailed and accurate.
■ All network components and connections are clearly labeled.
■ The diagram includes the OIT network as well as the provider
○ Include contact information for the Last-Mile provider.
○ Specify the SLA with the provider, including guaranteed uptime and response times.
○ Acceptance Criteria:
■ Contact information is complete and accurate.
■ SLA meets or exceeds the minimum requirements outlined in the
RFP.
Example 3: Cellular Tower Location
● Location: [Specific address of the cellular tower]
● Technology: 5G
● Backhaul:
○ Provider: [Name of the backhaul provider]
○ Technology: [Specify the backhaul technology, e.g., fiber, microwave]
○ Bandwidth: [Specify the backhaul bandwidth]
○ Acceptance Criteria:
■ Provider is a reputable and reliable company.
■ Technology is appropriate and meets the requirements.
■ Bandwidth is sufficient for the needs of the tower.
○ [List of equipment installed at the tower, e.g., 5G antennas, baseband units]
○ Include model numbers and specifications for each piece of equipment.
○ Acceptance Criteria:
■ Equipment list is complete and includes all necessary components.
■ Specifications are accurate and meet the requirements outlined in the RFP.
including the location of the tower, the backhaul provider's network, and any intermediate points.
○ Acceptance Criteria:
■ Diagram is detailed and accurate.
■ All network components and connections are clearly labeled.
■ The diagram includes the OIT network as well as the provider
○ Include contact information for the backhaul provider.
○ Specify the SLA with the provider, including guaranteed uptime and response times.
○ Acceptance Criteria:
■ Contact information is complete and accurate.
■ SLA meets or exceeds the minimum requirements outlined in the
RFP.
Note: These examples are not exhaustive and serve as a guide for the level of detail expected in the deliverables. The specific information required may vary depending on the location and the chosen technology. Vendors are encouraged to provide comprehensive documentation that allows OIT to fully understand and evaluate the proposed solutions.