This document is a Return to Service Letter for a storage tank inspection at Fort Irwin, associated with the USACE Contract No. W9128F25QA042. The letter documents an API 653 tank inspection performed by a certified inspector, confirming the tank is suitable for return to service with no mandatory repairs requiring immediate attention. The inspection was conducted in compliance with API Standard 653, with recommended future inspection dates specified for out-of-service and in-service tank assessments, including ultrasonic testing for roundness and corrosion evaluations. The document is signed by an API 653 Certified Inspector and includes acknowledgment spaces for the installation point of contact and USACE Fuels Project Manager, indicating formal documentation of the tank's inspection and serviceability status.

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

[COMPANY Letter Head]

DATE

Subject: RETURN TO SERVICE LETTER

STORAGE TANK NO. [ XXXXX]

Fuel System Inspection, [Location] Contract No. [XXXXX], Task Order [XX] Out-of-Service [API 653] Inspection

Tank [XXX] was inspected for serviceability evaluation in accordance with the requirements of [API STD 653, XX Edition, Date.]. The Inspection was performed by [Company Name] on [ddmmmyy].

The results of the inspection: The tank is in suitable condition for return to service. There are no mandatory repairs that require immediate attention, in order to prevent imminent risk to system operators, equipment integrity, or the adjacent environment.

The Tank was returned to service on [date].

RECOMMENDED FUTURE INSPECTION DATES no later than (NLT):

API 653 Out-Of-Service tank inspection[date]
API 653 In-Service tank inspection[date]
…UT Roundness…Corrosion…etc[date]

SATE REGULATIONS (N/A if Not Applicable):

[State] Regulations follow [……] State Regulations for API 653 Out-Of-Service tank inspections is NLT [date]

Final documents will be included in the close out documentation as required by the task order.

Prepared by:

[Inspectors Name] [Title] [Company] API 653 Certified Inspector No. [XXXX]

Installation acknowledgement:

[Installation Point of Contact Name] [Title]

[USACE Fuels Project Manager] Fuels Project Manager

USACE-NWO-PMS-C

[USACE Fuels Project Manager Email]@usace.army.mil