This document provides fabrication details and specifications for identity panels and arrowheads for the Channel Islands National Park sign program. Western red cedar wood will be used for panels with a maximum moisture content of 12%. Panels will be constructed of vertical grain lumber glued together to specified dimensions. Typography will be NPS Rawlinson Heavy and Frutiger Bold machine routed to specified depths. Panel graphics and layouts will match provided drawings. All surfaces will be stained or painted according to specifications. The related federal contract opportunity is for the CAHA SIGN PLAN solicitation issued by the National Park Service, Department of the Interior.

View the file

Other files

File Type Posted
Attachment_Y_HFC_Editorial_Style_Guide.pdf PDF
Attachment_M_Motorist_Guidance_Fabrication_Details.pdf PDF
Attachment_T_ORV_Beach_Access_Map.jpg JPG image
Attachment_R_Temporary_Signs.pdf PDF
Attachment_I_VIS_Entrance_Fee_Signs.pdf PDF
Attachment_A_CAHA_Sign_Recommendations_Report.pdf PDF
Attachment_F_Identity_Sign_Examples.pdf PDF
Attachment_D_Identity_Sign_Colors.pdf PDF
Attachment_Za_NPS_Wayside_Map_Standards.pdf PDF
Sol_140P2124Q0026.pdf PDF
Attachment_G_VIS_Templates.pdf PDF
Attachment_K_VIS_Trailhead_Examples.pdf PDF
Attachment_C_Identity_SIgn_Grids.pdf PDF
Attachment_V_Draft_Hatteras_Light_Station_Landscape_Plans.pdf PDF
Attachment_U_Lighthouse_Road_Trail_Plans.pdf PDF
Attachment_X_HFC_Spanish_Style_Guide.pdf PDF
Attachment_Ze___CAHA_Pricing_Sheet.xlsx XLSX spreadsheet
Attachment_H_VIS_Hardware_Manual.pdf PDF
Attachment_N_Motorist_Guidance_Boundary.pdf PDF
Attachment_Q_NPS_Sign_Colors.pdf PDF
Attachment_J__VIS_Standard_Firearms_Signs.pdf PDF
Attachment_W_Off_Road_Vehicle_Management.pdf PDF
Attachment_Zd__Schedule_Template_for_CAVE.xlsx XLSX spreadsheet
Attachment_Zc_Raised_Characters_in_Frutiger.pdf PDF
Attachment_B_NPS_Identity_Sign_Manual.pdf PDF
Attachment_P_Arrowhead_Vector_Art_and_Colors.pdf PDF
Attachment_O_NPS_Symbols.pdf PDF
Attachment_L_Motorist_Guidance_Sign_Grids.pdf PDF
Attachment_Z_NPS_Programmatic_Accessibility_Guidelines.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Arrowhead Fabrication Detail

National Park Service | Harpers Ferry Center | NPS Sign Program D.9

Channel Islands National Park

Description | Notes

VIS - Pedestrian Directional

Double post ground mount assembly with western red cedar panel

Project Number

0909-807-CHIS

Drawing Date

02/19/19

Location Number(s)

Scale

1/2" = 1' - 0"

Page

Router Depth 1/8"

45°

Threaded Rod and Drywall

Anchor

Chamfered Edge

Epoxy Anchors

Use Triangle Pattern To Determine Mounting Hole Location

Sky: Not Routed

Mountain: Not Routed

Lake: Not Routed

Bison: Not Routed

Text: Routed

Chamfered Edge

Snow: Routed

Foreground and Trees: Routed

PMS 553 PMS 1615 PMS 1605White

NPS Arrowhead Routing Details

Western Red Cedar, dried to a minimum of 12% moisture content prior to fabrication. All non-routed areas remain at the surface level of the original material.

Arrowhead Chamfer Detail

Arrowhead Mounting Detail Arrowhead Mounting Side Section

1/4" Chamfer

4-4.0G

Match Colors:

Routed and Painted Wood Arrowheads

Western Red Cedar, dried to a minimum of 12% moisture content prior to fabrication. All non-routed areas remain at the surface level of the original material.

Arrowheads 12 inches tall and greater are to be 1.5 inches thick. Arrowheads smaller than 12 inches shall be 1 inch thick.

Arrowheads shall be sprayed using a VOC compliant, Mathews White Epoxy Primer (or approved equal) on all surfaces.

Wood shall receive a minimum of two primer coats prior to top coat finishes. Primer coats shall be applied in strict accordance with the paint manufacturer’s specifications.

Final top coat colors shall be a Matthews Satin VOC, Semi Gloss finish.

Attachment E

Panel Detail

Identity Signs: Material Overview and Fabrication Specifications

Wood Panel

45° 45°

1/

2"

Wood Panel

1/

2"

3/ 8"

Routed NPS Rawlinson Typography Section Cut

Actual Size

Routed Frutiger Typography Section Cut

Actual Size

National Park Service | Harpers Ferry Center | NPS Sign Program D.8

Channel Islands National Park

Description | Notes

VIS - Pedestrian Directional

Double post ground mount assembly with western red cedar panel

Project Number

0909-807-CHIS

Drawing Date

02/19/19

Location Number(s)

Scale

1/2" = 1' - 0"

Page

Typical Western Red Cedar ID Panel Details, Alternate Layout

Channel Islands National Park Prisoners Harbor National Park Service U.S. Department of the Interior

0.250" Deep Routed Dado Line

0.125" Deep, 1/8” Oversized to Accommodate Arrowhead Insert

Identity Signs: Material Overview and Fabrication Specifications

National Park Service | Harpers Ferry Center | NPS Sign Program D.7

Channel Islands National Park

Description | Notes

VIS - Pedestrian Directional

Wall mount assembly with western red cedar panel

Project Number

0909-807-CHIS

Drawing Date

06/01/20

Location Number(s)

Scale

1/2" = 1' - 0"

Page

Wood Panels

Western Red Cedar for NPS Park Identity Signs:

WRC for NPS Park Identity signs shall be laminated clear heart, kiln-dried vertical grain with a maximum moisture content not to exceed 12%. Cedar shall be selected per grading rules of the Western Red Cedar Lumber Associa-tion. Components of all panels including end caps shall be fabricated from the same grade.

Panel Size:

Sign panel shall be fabricated based on dimensions and format specified in the Sign Drawing Package. Panel sizes, specifications, dimensions, typography, color, and proportions shall not be altered.

Panel Assembly:

Panels shall be constructed using clear heart, vertical grain, kiln-dried wood through, glued up one board thick using 2" nominal size dimensional lumber (2" x 6", 2" x 8", 2" x 10"). Panels shall be glued using a phenolic resorcinol moisture resistant adhesive with all surface joints covered. Panels shall be clamped and cured for a minimum of 24 hours or per the manufacturers specifica-tions. Panel fabrication shall occur in air temperatures between 70 and 90 degrees Fahrenheit during drying, adhesive application, and curing.

After curing the panel vertical edges shall be finished with a 2" x 2" vertical end strip, faced glued and reinforced with 3", No 12 stainless steel Phillips flathead screws placed 8" on center. Screw heads shall be counter-sunk to a depth of 3/8" and filled with glue-in wood plugs.

After end strips have cured the panels shall be machine planed to a finish thickness of 1-1/2". All surfaces shall be finish sanded smooth and face and back edges shall rounded to a radius of 1/8".

Panels shall not be finished with hand planes, hand-held belt, orbital, or vibrating sanders.

Graphic Layout:

Graphic layout of panels shall be as shown on the attached drawings. Graphics to be accurately reproduced from plotted outline template or directly from computer to router based on full size digital vector art. Contractor shall use an accurate grid to ensure layout is aligned vertically and horizontally.

Typography shall be NPS Rawlinson Heavy and Frutiger Bold as shown on attached drawings. Typography shall not be altered, manipulated, or changed. Substitute fonts shall not be used.

NPS Rawlinson Heavy shall be Machine-routed unless otherwise specified with a 90 degree “V" router bit with a 1/8" vertical, flat sidewall inset. Routed letters shall conform to the same size artwork. Routing depth shall be uniform. Corners of type smaller than 3" cap height shall have a radius no greater than 0.0625. Type larger than 3" cap height shall have a corner radius no greater than 0.125".

Frutiger Bold typography shall be Machine-routed unless otherwise specified using a vertical-sided, flat-bottom router bit. Routing depth to be 0.375".

Vertical dados shall be routed to a depth of 0.250".

Vertical dado width shall be based on the cap height of main typography (0.0833 x cap height - .25" for 3", 0.333" for 4", .50 for 6"). Vertical dados shall be painted as specified below.

Panels receiving an NPS Arrowhead shall be Machine-routed to a depth of 0.125" using a vertical-sid-ed, flat-bottom router bit in Overbar section of panel for NPS Standard Panel layouts or Main Sign Panel for NPS Alternate layouts. Arrowhead silhouette routed in the sign panel shall be oversized by 1/8" to accommodate inset NPS Arrowhead.

All routed type, dados, and insets shall be sanded smooth and clean. All edges shall be free of burrs and all edges eased prior to application of primer coats and paint.

Paint/Stain:

Prior to painting or staining, wood shall be Machine drum sanded, not finished with hand planes, hand-held belt, orbital, or vibrating sanders. All sawdust and sanding residue shall be removed. Wood shall be properly cleaned per paint manufacturer’s instructions.

Surfaces shall be wiped clean using a Matthews (or approved equal) Speed Prep Cleaner formulated for use on wood. All panel surfaces shall be completely dry prior to primer application.

1. Main Panel Face, sides, top, bottom, and panel back shall be solid-color stained to match colors specified in drawings. Must use Olympic Advanced Solid Stain and Sealant or approved equal. Panels shall receive a minimum of two coats. Stain shall be applied in strict accordance with the manufacturer's specifications.

2. Panel Typography and Vertical Dado shall be painted white, Satin finish.

3. Edges between type, dados, and flat panel sections shall be clean and sharp. Ragged edges and transitions, drips, and oversprays and not acceptable.