Attachment_E_Lead_Based_Paint_Survey.pdf

PDF 6 MB Posted

Attached to
Demolition of Former Motel in Micco
Solicitation number
B-2-26-38
Issued by
Brevard County, Miramar Beach CDP, Florida

About this file

This is a Lead-Based Paint (LBP) Survey Report prepared by UES for Brevard County Public Works Facilities regarding the Micco Hotel located at 8820 and 8830 Highway 1 in Micco, Florida. The survey was conducted on October 20, 2025, by certified inspector Brandon Selph under the supervision of EPA Certified Lead Paint Risk Assessor Robert B. Sport to identify and assess suspect lead paint on building surfaces that may require appropriate removal, handling, and disposal procedures prior to planned demolition and renovations. The testing was performed in conformance with HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (June 1995). A total of 47 component coatings were tested using X-Ray Fluorescence (XRF) technology, with calibration checks performed at the beginning, every four hours, and at the conclusion of the inspection using NIST lead standards.

The survey findings indicate that none of the components tested positive for lead at or above the HUD classification threshold of 1.0 mg/cm² (95% confidence level). Nine components tested within the negative range of 0.1 to 0.9 mg/cm², including door jambs, roof components, wall surfaces, doors, floors, and window frames, which fall below EPA lead-based paint classification but remain subject to OSHA regulations if disturbed. No paint chip samples were collected or analyzed since XRF readings were obtained from all tested surfaces. The report emphasizes that any components not tested or located in areas not inventoried should be tested before disturbance, and that disturbance of any materials containing lead must be performed only by properly trained personnel using controlled and documented procedures in compliance with OSHA, EPA, HUD, and RCRA regulations. The controlling agencies identified are the Florida Department of Environmental Protection Central District and EPA Region 4.

View the file

Other files

File Type Posted
Notice_of_Award.pdf PDF
Bid_Tabulation__Intent_to_Award.pdf PDF
Bid_Tabulation__Names_Only.pdf PDF
Addendum_2.pdf PDF
Attachment_G_Boundary_Survey.pdf PDF
Addendum_1.pdf PDF
Attachment_A_Aerial_Survey.pdf PDF
Attachment_C_OSTDS_DOH_Op_Permit_Expired.pdf PDF
Attachment_B_Septic_Well_Line.pdf PDF
Attachment_D_Asbestos_Survey.pdf PDF
Attachment_F_General_Conditions.pdf PDF
INV_&_SPECS.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEAD-BASED PAINT SURVEY REPORT

Micco Hotel 8820 and 8830 Highway 1 Micco, Brevard County, Florida 32976 UES Project No. A25146.01691.000 UES Report No. 2158880

Report Date: October 21, 2025

Prepared for:

Brevard County Public Works Facilities 2725 Judge Fran Jamieson Way, Suite 201 Viera, Florida 32940 Attention: Mr. James Monarchy Construction Coordinator

Prepared by:

UES

820 Brevard Avenue Rockledge, Florida 32955

(321) 638-0808 www.TeamUES.com

ATTACHMENT E - LEAD BASED PAINT SURVEY

820 Brevard Avenue | Rockledge, FL 32955 | p 321-638-0808 | f 321-638-0978 | Team UES.com

October 21, 2025

Brevard County Public Works Facilities 2725 Judge Fran Jamieson Way, Suite 201 Viera, Florida 32940

Attention: Mr. James Monarchy

Reference: Lead-Based Paint Survey Report Micco Hotel 8820 & 8830 Highway 1 Micco, Florida UES Project No. A25146.01691.000 UES Report No. 2158880

Dear Mr. Monarchy

On behalf of Brevard County Public Works Facilities (the “client”), UES has completed this LBP Survey Report.

UES performed this LBP survey on October 20, 2025, to identify and assess suspect lead paint on within the subject buildings that may require appropriate removal, handling, and disposal procedures prior to planned demolition/renovations at the subject property. The testing of the selected areas was performed in general conformance with the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing, dated June 1995.

A total of 47 readings were taken including for calibration purposes. None of the components tested positive for lead (i.e. equal to or greater than 1.0 mg/cm2 with 95% confidence). Additional details regarding the LBP Survey conducted by UES are presented in the attached report.

UES appreciates this opportunity to provide environmental services to you and we look forward to future endeavors. If you have any comments or questions regarding the information contained within this report or if we can be of further service, please contact the undersigned.

Respectfully submitted, UES Professional Solutions

Written by, Reviewed by, Brandon Selph Robert B. Sport, CIAQP Senior Project Manager EPA Certified Lead Paint Risk Assessor bselph@teamUES.com Certification No. FL-R-6414-3 i

TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Special Terms and Conditions

1.2 Conditions and Limitations of this Survey

1.3 Purpose and Scope of Work

1.4 Inspection Procedures

2.0 X-RAY FLUORESCENCE (XRF) TESTING

2.1 XRF Specification and Testing Protocol

2.2 XRF Calibrations

2.3 XRF Operations

3.0 FINDINGS

3.1 “Positive” XRF Readings

3.2 “Negative” XRF Readings

4.0 LABORATORY ANALYSIS (PAINT CHIP SAMPLES)

5.0 REGULATORY INFORMATION

5.1 LBP Definition

5.2 EPA – Renovation, Repair and Painting Program

5.3 OSHA

5.4 HUD

5.5 Lead Paint Abatement

5.6 EPA Regulations

5.2 OSHA Regulations

6.0 CONTROLLING AGENCY

ii

LIST OF FIGURES AND APPENDICES

APPENDIX A

Subconsultant Work Order and Project Agreement........................................................................A

APPENDIX B

Inspector(s) & Reviewer Certifications ............................................................................................ B

APPENDIX C

Summary of XRF Results .................................................................................................................. C iii

GLOSSARY OF ACRONYMS

μg/m3 – cubic meter of air AIHA – American Industrial Hygiene Association CFR – Code of Federal Regulations ELLAP – Environmental Lead Laboratory EPA – Environmental Protection Agency FAC – Florida Administrative Code FDEP – Florida Department of Environmental Protection HUD – United States Department of Housing and Urban Development LBP – Lead-Based Paint mg/cm2 – milligrams of lead per square centimeter MSW – Municipal Solid Waste NESHAP – National Emissions Standards for Hazardous Air Pollutant NIST – National Institute of Standards and Technology OSHA – Occupational Safety and Health Administration RRP Rule – Renovation, Repair and Painting Rule PEL – Permissible Exposure Limit PPE – Personal Protective Equipment PPM – Parts per Million RCRA – Resource Conservation and Recovery Act RMD – Radiation Monitoring Devices, Inc.

TCLP – Toxicity Characteristic Leaching Procedure TWA – Time Weighted Average XRF – X-Ray Fluorescence

Lead-Based Paint Survey Report UES Project No. A25146.01691.000 Micco Hotel UES Report No. 2158880 8820 & 8830 Highway 1 Micco, Florida October 21, 2025

1.0 INTRODUCTION

UES conducted an LBP Survey on the subject building located at 8820 & 8830 Highway 1 Micco, Florida.

UES understands that the subject buildings may be slated for demolition/renovations in connection with proposed re-development plans. LBP, as defined by the HUD, is dried paint film with a lead concentration equal to or greater than 1.0 mg/cm2 when measured by a portable XRF Lead Paint Analyzer, or a lead concentration of 5,000 ppm or 0.5 percent by weight when analyzed by an AIHA/ELLAP laboratory.

This report is not intended for compliance with 40 CFR part 745.

1.1 Special Terms and Conditions

This service was conducted based on the written authorization of Brevard County Public Works Facilities, dated October 3, 2025. This survey was conducted in accordance with the Work Order #5078109 and Project Agreement, which are incorporated into the Client authorized agreement that governs this survey.

A copy of the Work Order #5078109 and Project Agreement is presented in Appendix A.

A Work Order #5078109 and Project Agreement was made on October 3, 2025 between UES and Brevard County Public Works Facilities A copy of the Work Order #5078109 and Project Agreement is presented in Appendix A.

1.2 Conditions and Limitations of this Survey

Complete destructive observation and sampling procedures were not generally used in UES’s evaluation of the subject building. Inaccessible areas within the building(s), such as crawl spaces, inside other sealed areas, behind architectural details are beyond the scope of this study. The scope of UES’s inspection did not include an evaluation of the structure’s fixtures, equipment, or stored materials.

Due to the age, use and construction of the subject building(s) LBP may have been used/present in the past but may have been removed or partially removed and some residue from previous or removed LBP could still exist. UES has no knowledge or documentation of such.

A representative of UES performed the XRF LBP inspection on October 20, 2025, . This survey is applicable for the time that the inspection was conducted. Component surface coatings that were not tested by UES should be tested before any disturbance to the components (such as repair, renovation, or demolition). The testing results may not be acceptable for activities (such as renovation and repair) which may disturb the coatings and be regulated by OSHA. Inaccessible areas within the subject buildings, such as inside partitions, inside crawl spaces, inside other sealed areas and behind architectural details are beyond the scope of this study. The scope of our investigation did not include an evaluation of components on the roof, fixtures, equipment, or stored materials. This report is not intended for compliance with the EPA 40 CFR part 745.

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

1.3 Purpose and Scope of Work

The purpose of this study was to perform an evaluation of the above-referenced facility for the presence of LBPs, specifically those building surfaces/components which may be present or impacted during potential demolition/renovation activities. The activities and procedures used to accomplish this task were as follows:

1) Review available information concerning the subject buildings including the dates of initial construction, significant renovations, types of construction, and information regarding the on-site structures uses.

2) Visual building inspection of accessible areas by an inspector to identify, locate, and assess suspect LBP.

3) Once identified, measure suspect LBP with a portable XRF Lead Paint Analyzer on all combinations of assessable painted, glazed, shellacked, and/or stained components.

4) Due to the size, shape and/or location of some components, XRF readings of these component coatings may not be possible. Typically, collections of paint chip samples from these component coatings are then obtained. Analysis of any collected paint chip samples are performed by an AIHA/ELLAP accredited laboratory using FAA EPA method SW-846, 3rd edition, 7420 for the presence of lead.

5) Prepare and submit a report.

1.4 Inspection Procedures

The lead-based paint survey was performed on October 20, 2025, by Brandon Selph under the supervision of Robert B. Sport, an EPA Certified Lead Paint Risk Assessor. A portable Radiation Monitoring Devices, Inc.

(RMD) LPA-1 XRF analyzer was used to analyze components for LBP. Mr. Selph is certified by RMD to operate the LPA-1 Analyzer. Refer to Appendix B for the certifications.

2.0 X-RAY FLUORESCENCE (XRF) TESTING

2.1 XRF Specification and Testing Protocol

The RMD LPA-1 XRF Analyzer method of measurement is based on spectrometric analysis of lead K-shell XRF within a controlled depth of interrogation. K-shell measurements of lead in paint is the EPA/HUD’s preferred method of XRF measurement. The K-Shell line (the higher energy emission) is normally used for paint analysis because it measures lead in all layers of paint films, including those layers nearest the substrate where higher lead levels are often found. K-shell X-rays can penetrate multiple layers of paint and/or various other coatings without being affected by the thickness and composition of the layers. The RMD LPA-1 XRF Analyzer uses a controlled depth concept which restricts the penetration of the energetic K-shell X-rays into the substrate so that the analyzer will not locate objects deep in a wall or component such as lead pipes. The RMD LPA-1 XRF Analyzer distinguishes the lead X-ray from interfering X-ray radiation from other metals. The RMD LPA-1 XRF Analyzer calculates and then displays the specific lead content as mg/cm2 of surface area.

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

The portable RMD LPA-1 XRF Analyzer was operated in general accordance with the manufacturer's specifications. The testing of the selected areas was performed in general conformance with the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing, dated June 1995.

2.2 XRF Calibrations

The EPA/HUD protocol requires calibration checks on the portable XRF analyzer. The calibration checks are performed at the beginning of the inspection, and/or every four hours, and at the conclusion of the inspection. Calibration checks were performed to determine if the instrument was operating properly. Three calibration test measurements lasting a minimum of 32 seconds per measurement are collected on a selected NIST lead standard. The average of the three readings are recorded and compared to the known value of the standard provided by the manufacturer. All calibration checks for the portable RMD LPA-1 XRF Analyzer (Serial No. 1927) were within the manufacturer's parameters.

2.3 XRF Operations

The portable RMD LPA-1 XRF Analyzer was operated utilizing the "Quick Mode" (95% confidence) sampling mode with an "action" level of 1.0 mg/cm2 as described in the EPA/HUD Guidelines. Each XRF result (K-Shell reading) was categorized as negative or positive. XRF readings equal to or greater than 1.0 mg/cm2 are classified as positive. XRF readings less than 1.0 mg/cm2 are classified as negative as described in the EPA/HUD Guidelines.

3.0 FINDINGS

A total of 53 XRF readings, including calibrations, were performed at the subject building(s). Refer to the Summary of XRF Results in Appendix B for information pertaining to the locations and results of the XRF readings.

3.1 “Positive” XRF Readings

None of the component coatings tested had XRF readings equal to or greater than the “positive” classification of 1.0 mg/cm2.

3.2 “Negative” XRF Readings

Nine of the 47 component coatings tested had a XRF reading in the “negative “range of 0.1 mg/cm2 to 0.9 mg/cm2, which is below the HUD “positive” classification of 1.0 mg/cm2. The negative XRF readings are summarized in the table below.

“Negative” XRF Readings (0.1 to 0.9 mg/cm2)

Reading # Room/Location Substrate Color Component Results (mg/cm2)

8 Unit 106 Wood White Door Jamb 0.1

11 Unit 104 Wood Brown Door Jamb 0.1

15 Roof Metal Green Roof 0.3

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

“Negative” XRF Readings (0.1 to 0.9 mg/cm2)

Reading # Room/Location Substrate Color Component Results (mg/cm2)

17 South Wall Stucco Tan Orange Wall 0.3

22 Unit 106 Metal Blue Door 0.2

24 Unit 106 Concrete Gray Floor 0.2

33 Unit 103 Metal White Door 0.1

34 Unit 102 Metal Red Door 0.1

39 Unit 102 Wood yellow Window Frame 0.3

While the components listed in the table above fall within the “negative” range and are not considered lead paint by the EPA; should these colors/components be disturbed, they are subject to regulation by OSHA. The remaining component coatings were documented with XRF readings below the instrument’s detection limit for lead.

4.0 LABORATORY ANALYSIS (PAINT CHIP SAMPLES)

UES was able to analyze and collect XRF readings from all of the tested surfaces/components during this LBP survey. As such, samples of paint chips were not collected or analyzed during the field inspection as part of this survey.

5.0 REGULATORY INFORMATION

LBP activities are governed by various regulations and guidelines. The regulations and guidelines are focused on the protection of building occupants, protection of the environment, disposal procedures, and worker protection.

The disturbance of LBP coatings is regulated by the OSHA, which has noted that the HUD LBP definition may not be applicable to regulations. The OSHA regulation does not define lead content of the coating, but instead, regulates the disturbance of the materials with any lead content.

The demolition of buildings is regulated under the NESHAP statue for general dust control. Specifications for the proper work practices, controls and disposal should be developed to document compliance with all applicable regulations.

Specifications for the proper work practices, controls and disposal should be developed to document compliance with all applicable regulations. Those components/colors not tested, or in locations not inventoried in this report, should be tested for lead content prior to any disturbance (repair, renovation, abatement, or demolition) that may cause airborne release of lead. Components/colors that may be identified to contain the presence of lead should not be disturbed in any uncontrolled manner, such as during repair, renovation or demolition. Any disturbance of these materials should only be done by properly trained personnel in a controlled and documented manner.

The disposal of commercial waste materials containing lead from renovation, abatement, and/or

8820 & 8830 Highway 1 Micco, Florida October 21, 2025 demolition is regulated by the RCRA. RCRA requires a waste toxicity characteristic on the waste by using TCLP (40 CFR 261.24). The TCLP extract is analyzed for lead (or other constituents) to determine if it is above or below the allowable toxic characterization regulatory threshold, which for lead is 5 ppm (milligrams/liter).

The FDEP issued Memorandum #SWM-21.36 on February 13, 2002, regarding Management of Lead-Based Paint Debris (Appendix D). This FDEP memo states the following:

This memo is intended to give counties guidance on the management of LBP debris. LBP debris includes lead-based paint building components plus chips, dust, contaminated soils, and sludge generated from lead abatement projects.

The EPA’s Office of Solid Waste issued a memo on July 31, 2000, clarifying that LBP debris from residences, whether generated by the homeowner or by contractors, is considered “household waste” and is thus exempt from regulation as hazardous waste under the RCRA. As such, this material can be disposed of as household waste in a MSW landfill or Waste-to-Energy facility and is exempt from hazardous waste testing requirements. This memo also includes several suggested for the proper handling and disposal of LBP debris.

The Department believes that designing a system that expedites the LBP debris remediation in a cost-effective matter, removes the exposure risk that LBP poses to human health, and gets this material into a proper and regulated management system that is protective of the environment is a sound approach that offers more protection and less process. The Department concurs with the EPA’s interpretation that LBP debris from a residence (including single family homes, apartment buildings, public housing, and military barracks) is “household waste” and is thus not subject to hazardous waste regulations. LBP debris generated from a commercial or industrial source is not entitled to this same exemption.

It is the Department’s experience that demolition debris which includes wood, concrete, or metal painted with LBP will generally not fail a TCLP test and so will not be regulated as a hazardous waste. Because of this, the Department will not expect generators of large pieces of LBP debris to characterize the waste stream through testing prior to disposal. Large sized pieces created from demolition jobs should be stored in containers, preferably covered, until ready for disposal in a Class I or III landfill or a C&D disposal facility, provided that the owner or operator is willing to accept them. All demolition contractors and others dealing with LBP debris should check with the facility owner where they intend to dispose of this material.

Generators of chips, dust, contaminated soils, and sludges from commercial or industrial sources which may be contaminated with LBP continue to be responsible for the proper characterization of the waste stream prior to disposal. Such materials generated from renovation or remodeling jobs that can be vacuumed, swept up, or otherwise easily collected should be subjected to the TCLP test. If the materials are determined to be hazardous, they must be managed accordingly.

If they are not hazardous, the materials should be placed into plastic bags or similar containers and taken to a class I landfill for proper disposal.

Dust, paint chips and other small LBP materials from households are not regulated as hazardous waste. Because this material can be “hazardous in nature” even though it may not be regulated as a hazardous waste, the Department does not consider it to be construction and demolition

8820 & 8830 Highway 1 Micco, Florida October 21, 2025 debris, and thus it cannot be disposed of at a Class III landfill or C&D disposal facility. These materials should be placed into plastic bags or similar containers and taken to a Class I landfill for disposal.

This memo addresses only the disposal aspects of LBP debris. The reader should be aware that other aspects of LBP abatement and management may be regulated by other entities. For example, EPA and HUD have issued health and safety management practices for the handling of this material, which recommends the use of gloves, dust masks, respirators when appropriate, and other Personal Protection Equipment.

Therefore, it has been our experience that the FDEP and OSHA allows components with lead containing coatings to remain in-place during general demolition provided that wet techniques and/or other engineering controls are employed during the process. Further, components that have lead containing coatings and debris mixed with lead containing coatings cannot be recycled and must be disposed in an appropriate landfill. With respect to lead related tasks such as any manual demolition of structures, manual scraping, manual sanding, heat gun applications, and power tool cleaning with dust collection systems, OSHA requires employee protective measures until the employer performs an employee exposure assessment and documents that the employee performing any of the lead related tasks is not exposed above the PEL of 50 μg/m3 averaged over an 8-hour period. UES recommends employee exposure monitoring during any lead related tasks.

5.1 LBP Definition

The EPA and HUD defines "lead-based paint" as any "paint, surface coating that contains lead equal to or exceeding one milligram per square centimeter (1.0 mg/cm2), a lead concentration of 5,000 ppm or 0.5% lead by weight.

5.2 EPA – Renovation, Repair and Painting Program

EPA's Lead RRP Rule requires that firms performing renovation, repair, and painting projects that disturb lead-based paint in homes, child care facilities and pre-schools built before 1978 have their firm certified by EPA (or an EPA authorized state), use certified renovators who are trained by EPA-approved training providers and follow lead-safe work practices.

5.3 OSHA

The current OSHA standard (29 CFR 1926.62) for lead exposure in construction has a ELP of 50 μg/m3, measured as an 8-hour TWA. As with all OSHA health standards, when the PEL is exceeded, the hierarchy of controls requires employers to institute feasible engineering and work practice controls as the primary means to reduce and maintain employee exposures to levels at or below the PEL. When all feasible engineering and work practice controls have been implemented but have proven inadequate to meet the PEL, employers must nonetheless implement these controls and must supplement them with appropriate respiratory protection. The employer also must ensure that employees wear the respiratory protection provided when it is required.

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

5.4 HUD

The Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (2012 Edition) enforce HUD’s vision to reduce hazards in housing in a cost-effective manner while protecting the health of children. These guidelines are used by those who are required to identify and control lead paint hazards, as well as property owners, landlords, and child-care center operators. Helpful advice on renovations in older housing, lead-based paint inspections and risk assessments, and where to go for help can be found in the guidelines. The guidelines also outline what users must do to meet requirements and recommendations; identify training – and if applicable, certification – required for people who conduct the work; and describe how the work should be done.

5.5 Lead Paint Abatement

Several approaches can be taken when dealing with LBP and leaded coatings that are intact and in good condition. LBP/leaded coatings can be removed, encapsulated, or enclosed. Worker protection and construction of an airtight containment around the work site, with few exceptions, are required where there is a disturbance. Depending on the abatement technique, airborne lead concentrations may be generated that may exceed the OSHA Lead in Construction Standard (29 CFR 1926.62).

Waste resulting from LBP coated component removal or removal of LBP by chemical stripping/mechanical removal is likely to result in the requirement for disposal in a hazardous waste facility. All lead paint and debris, whether from chemical or mechanical removal from its substrate, or whole component removal, must be tested to determine proper disposal. Waste characterization testing should be performed on all materials prior to making a disposal decision. Materials that are to be disposed of should be tested by the TCLP per EPA requirements to determine disposal requirements.

The disposal of commercial waste materials containing lead from renovation, abatement, and/or demolition is regulated by the RCRA. The TCLP extract is analyzed for lead (or other constituents) to determine if it is above or below the allowable TCLP regulatory threshold, which for lead is 5 ppm.

Note: OSHA regulates workers exposure to lead paint concentrations in any detectable amount.

Therefore, in order to satisfy OSHA requirements, worker protection and monitoring may be required for work activities that disturb paints that contain lead in any amount. In accordance with the OSHA Construction Standard for Lead (29 CFR 1926.62), it is the contractors’ responsibility to protect their workers when an employee may be occupationally exposed to lead.

Specifications for the proper work practices, controls and disposal should be developed to document compliance with all applicable regulations. Those components/colors not tested, or in locations not inventoried in this report, should be tested for lead content prior to any disturbance (repair, renovation, abatement, or demolition) that may cause airborne release of lead. Components/colors that may be identified to contain the presence of lead should not be disturbed in any uncontrolled manner, such as during repair, renovation or demolition. Any disturbance of these materials should only be done by properly trained personnel in a controlled and documented manner.

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

5.6 EPA Regulations

Residential Lead Based Paint Hazard Reduction Act of 1992, Public Law 102-550: Title X of the Housing & Community Development Act of 1992 Deals with training requirements for managing and procedures for evaluating the risks of identified LBP.

40 CFR 745 - Subpart L - Lead-Based Paint Activities Includes a "Model Accreditation Plan" outlining the training and certification program applicable to personnel performing lead-based paint activities.

40 CFR 745 - Subpart F - Disclosure of Known Lead-Based Paint and/or Lead-Based Paint Hazards Upon Sale or Lease of Residential Property Requires disclosure and an allowance for gathering of information concerning the presence or potential of lead-based paint hazards during a residential property sale.

Resource Conservation & Recovery Act Deals with the waste and disposal requirements associated with LBP materials.

5.2 OSHA Regulations

29 CFR 1926.62, Lead Exposure in Construction: Interim Final Rule Deals with the potential exposure to lead based paint materials to which construction workers may be subjected.

29 CFR 1910.134: Use of Respirators The OSHA Respiratory Protection Rule defines the program and requirements as to when personnel are allowed to wear respirators, maintenance of respirators, etc.

In general, OSHA coverage extends to all private sector employer and employees. Those not covered under the standard typically include self-employed persons and federal, state and local municipal employees.

The Office of Public & Indian Housing, Department of Housing & Urban Development Regulation are as follows:

Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (1995) Deals with requirements for testing and managing the potential for LBP exposure in public housing, primarily focused to the safety of children.

24 CFR 35 - Subpart H - Disclosure of Known Lead-Based Paint and/or Lead-Based Paint Hazards Upon Sale or Lease of Residential Property Requires disclosure and an allowance for gathering of information concerning the presence or potential of lead-based paint hazards during a residential property sale.

8820 & 8830 Highway 1 Micco, Florida October 21, 2025

6.0 CONTROLLING AGENCY

The Controlling Agency for the coordination of projects for Brevard County is the Florida Department of Environmental Protection, Central District, 3319 Maguire Boulevard, Suite 232, Orlando, Florida 32803- 3767, Mr. John Vigliotti and Ms. Wanda Parker-Garvin. Mr. Young can be reached at john.vigliotti@dep.state.fl.us. Ms. Parker-Garvin can be reached at wanda.parker@dep.state.fl.us. Both can be contracted at telephone number (407) 897-2938.

The Federal controlling agency is EPA Region 4, Sam Nunn Atlanta Federal Building, 61 Forsyth Street, Atlanta, Georgia 30303, (404) 347-4727.

APPENDIX A

Thomas-Wood, Tammy

Digitally signed by Thomas-Wood, Tammy DN: cn=Thomas-Wood, Tammy, email=Tammy.Thomas-Wood@brevardfl.gov Date: 2025.10.03 12:13:42 -04'00'

APPENDIX

Robert Bryan Sport has fulfilled the requirements of the Toxic Substances Control Act (TSCA) Section 402, and has received certification to conduct lead-based paint activities pursuant to 40 CFR Part 745.226 as:

All EPA Administered Lead-based Paint Activities Program States, Tribes and Territories

This certification is valid from the date of issuance and expires August 18, 2028

Certification #

LBP-R-6414-4

Issued On July 14, 2025

Adrienne Priselac, Deputy Director Land, Chemicals & Redevelopment Division

Risk Assessor

APPENDIX

File details come from the government source that posted it. Updated .