Attachment E - Cost Proposal Sheet_S-10700-00013696_final.pdf
PDF 118 KB Posted
- Attached to
- North Valley Complex Lab & Calibration Gases
- Solicitation number
- S-10700-00013696
- Issued by
- Clackamas County, Oregon
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Anaylsis Preferred Cylinder Type Preferred Cylinder Size Misc 2024 Usage for
ODA & OSHA Delivery Charges Hazmet Charges Monthly Cylinder Rental Offeror Notes
Air Ultra Zero O2 19.5% - 23.5% Type T high pressure Steel 310 cubic foot/feet ODA - 4
OSHA - 20
H20 2 ppm
CO2 0.5 ppm
CO 0.5 ppm
THC 0.1 ppm
Acetylene Atomic Absorption, 99.6% O2+CH4 4000 ppm Type A5 low pressure steel 360 cubic foot/feet ODA - 4
OSHA - 20
PH3 20 ppm
Argon Ultra High Purity 5.0, 99.999% O2 2 ppm Type T high pressure Steel 335 cubic foot/feet ODA - 5
OSHA - 6
H2O 3 ppm
THC 0.5 ppm
Argon High Purity 4.8, 99.998% O2 4 ppm Dewar LC200-350 PSI 200 liters ODA - 20
Helium Ultra High Purity 5.0, 99.999% N2 5 ppm Type T high pressure Steel 291 cubic foot/feet ODA - 10
OSHA - 1
O2 1 ppm
H2O 2 ppm
Hydrogen UHP 5.0, 99.999% N2 2 ppm Type T high pressure Steel 261 cubic foot/feet ODA - 3
OSHA - 2
O2 0.5 ppm
S-10700-00013696 NVC Lab & Calibration Gases
COST PROPOSAL SHEET
Gas Type
ATTACHMENT E
ODA & OSHA Delivery Charges Hazmet Charges Monthly Cylinder Rental Offeror NotesGas Type
H2O 0.5 ppm
CO2 0.5 ppm
CO 0.5 ppm
Nitrogen Liquid, High Purity, 5.5, 99.998% O2 5 ppm Dewar 22 PSI 200 liters ODA - 30
Nitrogen Semiconductor, 5.5, 99.9995% O2 0.5 ppm Type T high pressure Steel 304 cubic foot/feet ODA - 10
H2O 0.5 ppm
CO2 0.5 ppm
CO 1 ppm
H2 0.5 ppm
Nitrogen 99.999% UHP T 304 cubic foot/feet OSHA - 6
Oxygen Semiconductor, 5.0, 99.999% H2O 1 ppm Type T high pressure Steel 337 cubic foot/feet ODA - 1
N2 5 ppm
THC 0.5 ppm
CO 1 ppm
CO2 1 ppm
AR 5 ppm
KR 3 ppm
ODA & OSHA Delivery Charges Hazmet Charges Monthly Cylinder Rental Offeror NotesGas Type
Carbon Dioxide, 3.0 grade, 99.9% H2O 10 ppm High pressure steel 60 lb volume ODA -1
Nitrous Oxide Atomic Absorption 99.6% SP High pressure steel Size 200 OSHA - 1
Ammonia NH3 50 ppm ES = EcoSmart cylinder with M/T plug or approved equal 44 liters Calibration gas, 2 year shelf life OSHA - 1
Chlorine CI2 5 ppm ES 44 liters Calibration gas, 1 year shelf life OSHA - 1
Carbon Monoxide CO 50 ppm ES 116 liters Calibration gas, 4 year shelf life OSHA - 1
Carbon Dioxide CO2 2500 ppm ES 116 liters Calibration gas, 4 year shelf life OSHA - 1
5 way with/methane CO 200 ppm ES 34 liter Calibration gas, 4 year shelf
CO2 4%
H2S 20 ppm
CH4 2.50%
O2 18%
4 way with/methane CO 200 ppm ES 34 liter Calibration gas, 4 year shelf
CO2 4%
CH4 3%
O2 18%
4 way with/Pentane CO 100 ppm ES 34 liter Calibration gas, 2 year shelf
H2S 25 ppm
C5H12 0.35%
O2 19%
ODA & OSHA Delivery Charges Hazmet Charges Monthly Cylinder Rental Offeror NotesGas Type
Isobutylene C4H8 100 ppm ES 116 liters Calibration gas, 4 year shelf
Nitrogen N2 100% ES 116 liters Calibration gas, 4 year shelf
Nitrous Oxide N2O 100 ppm ES 34 liters Calibration gas, 4 year shelf
Sulfur Dioxide SO2 10 ppm ES 44 liters Calibration gas, 2 year shelf
Zero Air O2 20.90% ES 116 liters Calibration gas, 4 year shelf
Nitrogen Dioxide NO2 5.00 ppm ES 34 liters Calibration gas, 4 year shelf
Butane C4, H10, Butane, 47% LEL
116 RAL Certified, standard spec CGA C10 116 liters Calibration gas, Standard spec
CGA C10 OSHA - 1