This is a Comprehensive Asbestos Survey and Lead-Based Paint (LBP) Inspection report prepared by G2 Consultants for the Oregon Employment Department at the WorkSource Albany facility located at 139 SE 4th Avenue, Albany, Oregon. The inspection was conducted on February 2, 2026, in anticipation of an upcoming renovation project, with authorization from Christian Hargrove, Senior Construction Project Manager 2. The survey employed a comprehensive scope covering all readily accessible interior, exterior, and roofing materials, though destructive sampling techniques were not utilized to avoid irreparable damage to systems or hidden materials within wall cavities. The inspection identified four asbestos-containing materials (ACMs) with asbestos concentrations greater than 1%: sink undercoating in Break Room 111 containing 3% chrysotile; black mastic under cream floor tiles in the West Hallway and Room 106 containing 3% chrysotile; black tar on the roof access hatch and vents containing 2% chrysotile in poor condition; and cement board exterior siding containing 10% chrysotile in good condition, totaling 240 square feet. The report was completed on February 12, 2026.
Lead-based paint testing using X-Ray Fluorescence (XRF) analysis revealed no painted surfaces exceeding the EPA and HUD action level of 1.0 mg/cm², but lead was detected in the enamel glazing of six fixtures: sinks in the Custodial Closet (2.46 mg/cm²), Staff Women's Restroom (6.03 mg/cm²), Staff Men's Restroom (6.25 mg/cm²), Public Men's Restroom, Public Women's Restroom, and a toilet in the Staff Men's Restroom (3.42 mg/cm²). The report recommends that all identified ACMs be removed by a licensed asbestos abatement contractor prior to renovation activities, and that lead-safe work practices be implemented for fixtures testing positive for lead. All identified materials were analyzed by Eurofins Built Environment Testing West, LLC, an NVLAP-accredited laboratory, using EPA Method 600/R-93-116 for asbestos and XRF analysis for lead content. The facility, built in 1965, comprises approximately 11,205 square feet on one floor plus a mechanical penthouse.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Comprehensive Asbestos Survey & LBP Inspection Purpose: Pre-Renovation & Operations and Maintenance
Client:
Oregon Employment Department 875 Union Street NE Salem, Oregon 97311
Project:
PO#: 159413 - WorkSource Albany 139 SE 4th Avenue Albany, Oregon 97321
G2 Project #: G26-048
February 12, 2026
Prepared By:
G2 Consultants 7312 SW Durham Road Portland, Oregon 97224 888-998-4224 www.g2ci.com
CCB#: 253530
http://www.g2ci.com
Comprehensive Asbestos Survey & LBP Inspection G2 Consultants Project #: G26-048
Purpose of Inspection: Pre-Renovation & Operations and Maintenance
Scope of Inspection: Comprehensive - Interiors, Exteriors & Roofs
Project Description: WorkSource Albany
Project Address: 139 SE 4th Avenue Albany, Oregon 97321
Owner or Facility Operator:
Oregon Employment Department 875 Union Street NE Salem, Oregon 97311
Owner or Facility Operator Phone #:
541-280-0482
Technical Certifications
Consultant Discipline Certification # Regulatory Agency Phone Number
Chase Eckersell Asbestos Building Inspector
IRO-25-9965B EPA 971-485-5469
Andrew Lutz Lead-Based Paint Risk Assessor
2526-Indv-R
9152526-RA
OR Health Authority
OR CCB
503-798-8868
Page of 1 13
G2 Consultants | www.g2ci.com | 888-998-4224
Oregon Employment Department Comprehensive Asbestos Survey & Lead-Based Paint Inspection WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
Table of Contents
• Executive Summary
• Description of Structure(s)
• Scope of Inspection
• Inspection Findings
• Recommended Response Actions
• Methodology
• Limitations
Appendices
Appendix A: Asbestos Samples & Material Location Drawings
Appendix B: Laboratory Analysis Results & Chain of Custody
Appendix C: Photographs of Homogeneous Materials Sampled
Appendix D: XRF Readings Table
Appendix E: Performance Characteristic Sheet (PCS)
Appendix F: Certifications & Accreditation
Page of 2 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
G2 Consultants (G2) was retained by Oregon Employment Department (OED) to conduct a comprehensive building inspection for asbestos-containing materials (ACM) and lead-based paint (LBP). The survey was conducted at WorkSource Albany, located at 139 SE 4th Avenue, in Albany, Oregon. The scope of the inspection was comprehensive, including all interior, exterior and roofing materials in anticipation of an upcoming renovation project, as specified by OED. Authorization was provided by Christian Hargrove, Senior Construction Project Manager 2 with OED.
Date(s) of Inspection: February 2, 2026
Purpose of Inspection: Pre-Renovation & Operations and Maintenance
Scope of Inspection: Comprehensive - All readily accessible interior, exterior and roofing suspect asbestos-containing materials and painted building components. However, destructive sampling techniques were not utilized to gain access to potentially hidden materials such as within wall cavities or other interstitial spaces, or if sampling would result in irreparable damage like with siding systems, mechanical systems, mirrors, ceramic tile, etc.
Asbestos Results of this limited survey have determined that materials listed in the following table are ACMs, containing asbestos in an amount greater than 1%:
NOTE: Friability listed is based on conditions at the time of G2’s survey. Materials may become friable if disturbed.
* The material locations and quantities provided, represents the areas within the scope of work only. It does not represent the potential location/quantity of materials throughout the site.
Details of the inspection, descriptions and locations of materials, quantities, condition and friability can be found in the following sections of this report.
Lead-Based Paint None of the paint films analyzed were determined to contain lead concentrations above the United States Housing and Urban Development (HUD) and EPA Renovation, Repair and Painting (RRP) threshold for LBP of 1.0 milligram per centimeter squared (mg/cm2).
Executive Summary
Asbestos-Containing Materials Identified or Presumed - Overview
Material Description Material Location* Approx.
Quantity*
Condition Friable Y/N
Sink Undercoating, Light Gray Break Room 111 1 sink Good N
Mastic, Black, under Cream 12” x 12” Floor Tile
West Hallway and Room 106 (under carpet tiles)
185 sq. ft. Good N
Tar, Black Roof - Access Hatch and Vents 22 linear ft. Poor N
Cement Board Exterior - Siding 240 sq. ft. Good N
Page of 3 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
Lead above the 1.0 mg/cm2 threshold was identified in the enamel glazing of multiple sinks and a toilet within the building.
Details of the inspection can be found in the following sections of this report, and in the XRF Readings Table found in Appendix D.
Description of Structure(s)
Type of facility: Commercial Office Past uses: Commercial Office Age of construction: 1965
Approximate square footage: 11,205 sq. ft.
Number of floors: One plus Mechanical Penthouse
Outbuildings included in inspection: None Inaccessible rooms/areas: None
Aerial Photo of Subject Property Location of Subject Property
Page of 4 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
G2 was contracted by OED to conduct a comprehensive building inspection for ACM and LBP.
The survey was conducted at WorkSource Albany, located at 139 SE 4th Avenue, in Albany, Oregon. The scope of the inspection was comprehensive, including all interior, exterior and roofing materials in anticipation of an upcoming renovation project, as specified by Christian Hargrove with OED. The sampling was conducted to represent all suspect materials within the scope of work.
Asbestos The scope of services was to perform a visual and tactile inspection, and identify the presence, quantity and location of the accessible ACM, within the area(s) of the scope of work. All identified accessible suspect materials were sampled. The building was occupied and in operation at the time of the survey, therefore, destructive sampling techniques were not utilized to gain access to potentially hidden materials such as within wall cavities or other interstitial spaces, or if sampling would result in irreparable damage like with siding systems, mechanical systems, mirrors, ceramic tile, etc.
Lead-Based Paint The LBP inspection was performed in accordance with the U.S. Environmental Protection Agency Renovation, Repair and Painting Rule because it was conducted by a licensed LBP inspector using documented methodologies, such as those in Housing and Urban Development Guidelines Chapter 7 (2012 Edition), and the EPA RRP guidelines.
Readings of the lead content of painted components throughout the areas within the scope of work were collected using an X-Ray Fluorescence (XRF) device. The readings were taken from the predominant accessible interior and exterior paint films including surfaces coated with shellac, varnish, stain, etc., in order to provide a general indication of the distribution of lead. Ceramic tile and other non-paint surfaces (bath tubs, sinks, toilets, etc.) were tested for lead content due to the possibility of lead exposure during demolition or renovation activities. All Federal and State regulations governing the inspection of LBP were followed.
Other suspect ACMs and LBP may be present in the building that are outside this limited scope of work, or in areas that were not accessible at the time of the survey. Furthermore, the material locations and quantities provided in this report represents the accessible areas within the scope of work only. ACMs identified during this survey, if hidden or concealed, may potentially be located in additional rooms of the building, and at greater quantities than those stated in this report.
Scope of Inspection
Page of 5 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
Asbestos Results of this limited survey have determined that materials listed in the following table are ACMs, containing asbestos in an amount greater than 1%:
NOTE: Friability listed is based on conditions at the time of G2’s survey. Materials may become friable if disturbed.
† - Homogeneous material number
* The material locations and quantities provided, represents the areas within the scope of work only. It does not represent the potential location/quantity of materials throughout the site.
Results of this limited survey have determined that materials listed in the following table do not contain asbestos in an amount greater than 1%:
Inspection Findings
Asbestos-Containing Materials Identified or Presumed
HM
No.†
Material Description Material Location* Approx.
Quantity*
No. of Samples
Asb. Type & % Condition Friable Y/N
8 Sink Undercoating, Light Gray
Break Room 111 1 sink 2 Chrysotile 3% Good N
10 Floor Tile, 12” x 12” Cream, and Black Mastic
West Hallway and Room 106 (under carpet tiles)
185 sq. ft. 2 Floor Tile - None Detected
Mastic - Chrysotile 3%
Good N
22 Tar, Black Roof - Access Hatch and Vents
22 linear ft. 2 Chrysotile 2% Poor N
31 Cement Board Exterior - Siding 240 sq. ft. 2 Chrysotile 10% Good N
Non Asbestos-Containing Materials Identified
HM
No.†
Material Description Material Location* Asb. Type & % No. of Samples
1 Drywall and Joint Compound (w/Texture) Hamilton Room 105 and Central Cubicle Area
None Detected 3
2 Wall Texture, Orange Peel Hamilton Room 105 and Central Cubicle Area
None Detected 3
3 Sink Undercoating, Gray Hamilton Room 105 None Detected 2
4 Glue, Tan, under Carpet Tiles Throughout None Detected 2
5 Cove Base, 4” Black, and Cream Adhesive Throughout None Detected 2
6 Drywall and Joint Compound (w/Skim Coat) Throughout None Detected 3
7 Leveling Compound, White West Hallway None Detected 2
9 Leveling Compound, Gray Throughout None Detected 2
11 Floor Tile, 12” x 12” Light Gray w/White and Dark Gray Specks, and Tan Glue
Break Room 111 None Detected 2
Page of 6 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
† - Homogeneous material number
* The material locations provided, represents the areas within the scope of work only. It does not represent the potential locations/quantities of materials throughout the site.
Details of the samples collected, including locations of individual samples can be found in Appendix B: Laboratory Analysis Results & Chain of Custody.
Lead-Based Paint The types of components listed in the table below indicate the presence of lead at or above the EPA RRP and HUD Guidelines action level. The EPA and HUD definition of “positive” LBP is lead equal to or greater than 1.0 mg/cm2. Additional details including reading number, floor, substrate, side, color and lead content details are located in the XRF Readings Table found in Appendix D.
12 Floor Tile, 12" x 12" Gray w/Light and Dark Gray Specks, and Brown Glue
Mechanical Room 112 and Custodial Closet
None Detected 2
13 Duct Seam Tape, White Throughout None Detected 3
14 Glue, Tan, under Black Carpet Front Entrance and West Hallway
None Detected 2
15 Ceiling Tile, 2’ x 4’ Gouged w/Pinholes Throughout None Detected 2
16 Ceiling Tile, 12” x 12” Gouged w/Pinholes, and Brown Glue Dots
Staff Restrooms, First Aid Room, and Custodial Closet
None Detected 2
17 Terrazzo Flooring, White w/Gray Rocks Staff Women’s Restroom None Detected 2
18 Terrazzo Flooring, White w/Brown Rocks Staff Men’s Restroom None Detected 2
19 Terrazzo Flooring, Tan w/Brown Rocks Public Restrooms None Detected 2
20 Pipe Insulation Hard Fitting Throughout None Detected 4
21 Composite Roofing Exterior - Roof None Detected 4
23 Roofing Material, Black w/Silver Coating Exterior - Roof None Detected 2
24 Parapet Flashing Tar, Black Exterior - Roof Parapets None Detected 2
25 Sealant, White Exterior - Roof Vents None Detected 2
26 Sealant, Gray Exterior - Roof Vents and Flashing
None Detected 2
27 Sealant, Dark Gray Exterior - Roof Vents and Flashing
None Detected 2
28 Drywall (No Joint Compound) Mechanical Penthouse None Detected 2
29 Vapor Barrier, Brown Mechanical Penthouse None Detected 2
30 Brick Mortar, Gray Exterior - Siding None Detected 2
32 Caulking, Black Exterior - Doors and Windows None Detected 2
Non Asbestos-Containing Materials Identified
HM
No.†
Material Description Material Location* Asb. Type & % No. of Samples
Page of 7 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
NOTE: Readings in the table noted as LBP, are paint films with lead concentrations at or above 1.0 mg/cm2.
Readings in the table noted as Positive, are non-painted surfaces, such as ceramic tile, with lead concentrations at or above 1.0 mg/cm2
Per HUD guidelines, for each era of construction to be inspected, all testing combinations in each room equivalent were identified and tested by XRF. A testing combination is characterized by the room equivalent, the component type, and the substrate. A room equivalent is an identifiable part of a building (room, exterior, foyer, etc.). Painted surfaces include any surface coated with paint, shellac, varnish, stain, paint covered by wallpaper, or any other coating. Wallpaper was assumed to cover paint unless building records or physical evidence indicated no paint was present. At least one individual XRF reading was collected on each testing combination in each room equivalent. For walls, at least four readings were collected (one reading on each wall) in each room equivalent. A different visible color does not by itself result in a separate testing combination.
According to HUD Guidelines Chapter 7, if one testing combination (i.e. window, door) is positive for lead in an interior or exterior room equivalent, then all other similar testing combinations in those areas are also assumed to be positive for lead.
The XRF testing was conducted using an XRF lead paint analyzer. A surface-by-surface visual assessment of the painted and/or finished surfaces was conducted to determine which lead-coated surfaces/components are deteriorated at or above de minimis levels, specifically, the EPA’s minor repair and maintenance activities thresholds (40 CFR § 745.83). The EPA de minimis thresholds apply to work that disrupts: (a) 6 square feet or less of painted surface per room for interior activities; or (b) 20 square feet or less of painted surface for exterior activities; provided that none of the work practices prohibited or restricted by 40 CFR § 745.85(a)(3) were used and where the work does not involve window replacement or demolition of painted surface areas.
EPA regulations define deteriorated paint as, “any interior or exterior paint or other coating that is peeling, chipping, chalking or cracking, or any paint or coating located on an interior or exterior surface or fixture that is otherwise damaged or separated from the substrate" (40 CFR § 745.63).
Testing Combinations with Lead Equal to or Greater than 1.0 mg/cm2
Site Address Structure Component Room Equivalent Substrate Condition Result
139 SE 4th Avenue, Albany, OR
Main Building Sink Custodial Closet Enamel Intact Positive
Main Building Sink Staff Women’s Restroom
Enamel Intact Positive
Main Building Sink Staff Men’s Restroom
Enamel Intact Positive
Main Building Toilet Staff Men’s Restroom
Enamel Intact Positive
Main Building Sink Public Men’s Restroom
Enamel Intact Positive
Main Building Sink Public Women’s Restroom
Enamel Intact Positive
Page of 8 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
Asbestos
Results of the limited survey have determined that the sink undercoating in the Break Room, black mastic under the second-layer floor tile in the West Hallway and Room 106, black tar on the roof vents and roof access hatch, and cement board on the exterior are ACMs. All materials, except the black tar, were observed to be in good condition at the time of the survey.
The black tar was observed to be in poor condition at the time of the survey.
If any untested suspect materials are encountered during renovation activities, they should be assumed to be ACM and not disturbed, unless sampling and analysis of the materials proves otherwise.
Friability is determined by whether a material can be crumbled, pulverized or reduced to a powder by pressure of an ordinary human hand. The friability of materials listed in this report are based on the present state and actual conditions of the materials observed at the time of G2’s survey.
Materials listed as non-friable can become friable through impact or damage.
All identified and presumed ACM must be removed by a licensed asbestos abatement contractor, or other certified individual, prior to impact if they are to be disturbed during renovation activities. ACM remaining in the building should be managed in good condition, under an Operations and Maintenance Plan, and checked regularly for damage.
OR-OSHA requires a variety of actions when ACM is present in a commercial structure. These include labelling, warning signs, hazard communication and periodic inspections. All of the requirements of a building owner/operator with regard to asbestos can be found in Oregon Administrative Rules (OAR) 437, Division 2.
Any ACM likely to be disturbed during renovation or demolition activities, other than by incidental contact with no generation of debris related to other construction activities, should be abated by a licensed asbestos abatement contractor. Any activities conducted where the primary object of the activity is the removal of ACM must be conducted by a licensed asbestos abatement contractor or other properly trained individuals.
The National Emissions Standards for Hazardous Air Pollutants (NESHAPs) requires that all Regulated Asbestos-Containing Materials (RACMs) be removed from a building prior to demolition.
Recommended Response Actions
Asbestos-Containing Materials (ACM)
Any building material which contains asbestos in an amount greater than 1% is considered an ACM by the United States Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA), and by the State of Oregon Department of Environmental Quality (DEQ) and the Oregon Occupational Safety and Health Division (OR-OSHA).
Page of 9 13
G2 Consultants | www.g2ci.com | 888-998-4224 http://www.g2ci.com https://osha.oregon.gov/OSHARules/div2/div2Z-1001-asbestos.pdf https://osha.oregon.gov/OSHARules/div2/div2Z-1001-asbestos.pdf
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
No materials were identified during this survey that contained 1% or less asbestos.
Many of the engineering controls and work practices required by the EPA and OSHA are applicable only to materials that contain greater than 1% asbestos. However, OSHA has established work practice requirements and prohibitions that apply when asbestos is present in any quantity, and/or whenever worker exposure exceeds the PEL, regardless of the amount of asbestos in the materials involved. Applicable requirements for materials that contain 1% or less asbestos can be found in the OSHA Asbestos Construction Standard 29 CFR 1926.1101.
Lead-Based Paint No LBP was identified on any of the painted components analyzed as part of this limited inspection. Therefore, no further action regarding lead-safe work practices is required at this location for the painted components tested.
Lead above the 1.0 mg/cm2 threshold was also identified in the enamel glazing of multiple sinks and a toilet within the building.
Lead-containing paint (LCP), paint films with lead concentrations greater than zero but less than
1.0 mg/cm2, may be present on other painted surfaces. The presence/absence of LCP cannot be confirmed via XRF analysis.
LBP and LCP films could create lead dust or lead contaminated soil hazards if the paint is turned to dust by abrasion, scraping or sanding. If conditions of intact paint surfaces become destabilized, these conditions will need to be addressed. All paint films in poor condition must be stabilized if the structure is to be demolished.
If any construction or modernization work is done on the premises, contractors and other personnel who may impact these materials should be informed of the results of this inspection. The Occupational Safety and Health Administration (OSHA) and Oregon OSHA (OR-OSHA) have requirements for employees working with or around LBP and LCP.
LBP is a common cause of lead poisoning in children and represents a threat to the health and welfare of the occupants. Where economically feasible, it is our recommendation that all components that tested positive, and any similar untested components, be considered lead-laden, and lead-safe procedures is incorporated into any overall renovation and maintenance strategy in order to reduce the potential for contamination and/or exposure. Safe methods include: containing any work area to prevent dispersal of lead dust and chips, wet sanding and scraping at a minimum; collecting all paint chips and debris and, properly disposing of them.
Details of the locations and lead content for all of the readings can be found in Appendix D: XRF Readings Table.
Asbestos-Containing Materials - 1% Asbestos or Less
Any building material which contains asbestos in an amount of 1% or less is considered asbestos-containing by OSHA and OR-OSHA. Although these materials are not considered ACMs, workers must be protected from exposure to asbestos, regardless of the percentage.
Page of 10 13
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
If additional painted surfaces are discovered that were not tested as part of this inspection, or that are expected to be impacted as part of any renovation or demolition work, they should be presumed LBP until tested to show otherwise.
A risk assessment has not been conducted to evaluate potential lead hazards present at the building and surrounding soil as part of this scope of work.
Asbestos The field work was conducted using industry best practices. Samples of representative accessible suspect materials within the scope of work were collected during the course of the inspection.
Materials were sampled according to homogeneous groupings using the Asbestos Hazard Emergency Response Act (AHERA) sampling guidelines.
Asbestos samples were collected in such a manner as to minimize release of the material into the surroundings. Sample number, material description, sample location and material location were recorded at the time of sampling. Each sample was placed in a sample container labeled with a unique sample number and submitted to a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory, for analysis under chain of custody documentation. Samples were analyzed in accordance with EPA Method 600/R-93-116, using PLM with dispersion staining and using visual area estimation to determine percent asbestos content. This method allows for the identification of the primary types of asbestos used in building materials. The lower limit of detection for this method is one percent. Samples containing one percent or less asbestos by PLM with visual area estimation are reported as “Trace”.
Lead-Based Paint All testing of suspect LBP was conducted utilizing a SciAps X-ray fluorescence LBP analyzer, Model X550Pb (Rh) bearing Serial #01583. The device uses a rhodium X-ray fluorescence tube as opposed to a radioactive source. G2 followed the Performance Characteristics Sheets (PCS) for the specific X-Ray fluorescence instrument used during the LBP evaluation of the property. The XRF PCS is presented in Appendix E. The instrument was calibrated to the manufacturer's specifications and was also periodically verified against the National Institute of Standards and Testing (NIST) Standard Reference Material (SRM) 2579 lead film (1.0 mg/cm2).
The calibration of the instrument is conducted in accordance with the PCS for this instrument.
These instruments are calibrated using a calibration standard block of known lead content. If for any reason the instruments do not maintain a consistent calibration reading within the manufacturer’s standards for performance on the calibration block supplied by the manufacturer, manufacturer’s recommendations are used to bring the instrument into calibration. If the instrument cannot be brought back into calibration, it is taken off the site and sent back to the manufacturer for repair and/or re-calibration.
Wall “A” in each room is the wall where the front entrance door opening is located (or aligned with street). Going clockwise and facing Wall “A,” Wall “B” will always be to your right, Wall “C” directly
Methodology
Page of 11 13
G2 Consultants | www.g2ci.com | 888-998-4224 https://www.epa.gov/sites/production/files/documents/2003pt763_0.pdf https://www.epa.gov/sites/production/files/documents/2003pt763_0.pdf
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026 to the rear and Wall “D” to the left. Doors, windows and closets may be designated as left, center or right depending on their location on the wall. Doors, windows, and closets are designated as left, center or right depending on their location on the wall.
All individuals who performed this XRF testing and visual assessment have EPA and/or state licenses as Lead Inspector/Risk Assessors and have been trained in the use, calibration and maintenance of the XRF, along with the principles of radiation safety, in accordance with the work practices of 40 CFR 745, section 227, for states and Native American tribal groups.
G2 has performed this inspection in accordance with best industry methods and practices of the profession, and consistent with the level of care and skill ordinarily exercised by reputable environmental consultants under similar circumstances and conditions. The observations contained within this assessment are based upon site conditions readily accessible at the time of the site inspection. No other representation, guarantee or warranty, express or implied, is included or intended in this hazardous materials survey report.
The LBP portion of the inspection was planned, developed, and implemented based on G2’s professional experience in performing LBP inspections. G2 performed a limited inspection for lead-containing paint of the predominant painted surfaces in order to provide a general indication of the distribution of lead for demolition purposes. G2 utilized state-of-the-art practices and techniques in accordance with regulatory standards while performing this inspection. A copy of personnel and company certifications has been provided in Appendix F. G2’s evaluation of the painted surfaces identified during this inspection is based on conditions observed at the time of the inspection. G2 cannot be responsible for changing conditions that may alter the relative exposure risk for future changes in accepted methodology.
The owner is responsible to convey information regarding identified lead content to inhabitants, contractors, etc. expected to potentially be exposed. G2 recommends that both the contractor and the owner keep the records for three years.
This report consists of a visual survey, and XRF analysis of the readily accessible areas of this building and tested components. The presence or absence of LBP or LBP hazards applies only to the tested or assessed surfaces on the date(s) of the field visit and it should be understood that conditions may change due to deterioration or maintenance. The results and material conditions noted within this report were accurate at the time of the evaluation and in no way reflect the conditions at the property after the date of the evaluation.
As with all environmental investigations, this inspection is limited to the defined scope and does not purport to set forth all hazards, nor indicate that other hazards do not exist.
Limitations
Page of 12 13
G2 Consultants | www.g2ci.com | 888-998-4224 http://www.epa.gov/EPA-TOX/2001/January/Day-05/t84.pdf
WorkSource Albany - 139 SE 4th Avenue, Albany, OR February 12, 2026
Respectfully submitted and reviewed by:
| Chase Eckersell | Andrew Lutz | |
| Project Manager I | Director of Operations | |
| G2 Consultants | G2 Consultants |
Page of 13 13
Appendix A:
Asbestos Samples & Material
Location Drawings
7,8
18,19 28,29
42-44
16,17
Samples in RED are asbestos-containing materials.
* indicates sample should be considered asbestos-containing based on results of other samples of the material
Samples not shown: 45-50, *51, 52, 53-66
2-12-26
B ui ld in g:
Fl oo r:
D w g Ty pe
CE
1/1
This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.
Report North
W or kS ou rc e
A lb an y
1s t F lo or
S am pl e
Lo ca tio ns
C lie nt
P ro je ct
Lo ca tio n:
O re go n
E m pl oy m en t D ep ar tm en t
C om pr eh en si ve A sb es to s
S ur ve y
S E th
A ve nu e
A lb an y, O re go n
G
P ro je ct
G
-0
C lie nt
P ro je ct
Lo ca tio n:
C lie nt
P ro je ct
Lo ca tio n:
N ot es
7312 SW Durham Road Portland, Oregon 97224
888.998.g2ci www.g2ci.com
Floor Tile, 12" x 12" Cream, and Black Mastic (under carpet tiles)
Cement Board S Sink Undercoating
S
Material Not Shown: Tar, Black
2-12-26
B ui ld in g:
Fl oo r:
D w g Ty pe
CE
1/1
This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.
Report North
W or kS ou rc e
A lb an y
1s t F lo or
A C
M L oc at io ns
C lie nt
P ro je ct
Lo ca tio n:
O re go n
E m pl oy m en t D ep ar tm en t
C om pr eh en si ve A sb es to s
S ur ve y
S E th
A ve nu e
A lb an y, O R
G
P ro je ct
: G
-0
C lie nt
P ro je ct
Lo ca tio n:
C lie nt
P ro je ct
Lo ca tio n:
N ot es
7312 SW Durham Road Portland, Oregon 97224
888.998.g2ci www.g2ci.com
Appendix B:
Laboratory Analysis Results
& Chain of Custody
Approved by:
Technical Manager Ryan Talaski-Brown
Report for:
Chase Eckersell G2 Consultants 17750 SW Upper Boones Ferry Rd Suite 150 Portland, OR 97224
Regarding:
Eurofins Built Environment Testing West, LLC Project: G26-048; 139 4th Ave SE. Albany, OR 97321
EML ID: 4399356
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Built Environment Testing West, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 02-05-2026
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 200741-0
EMLab ID: 4399356, Page 1 of 19Eurofins Built Environment Testing West, LLC
Eurofins Built Environment Testing West, LLC 4321 S. Corbett Ave. Suite A, Portland, OR 97239
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Total Samples Submitted: 72 Total Samples Analyzed: 72
Total Samples with Layer Asbestos Content > 1%: 7
Location: G26-048-1, Drywall & Joint Compound (w/Texture)- Hamilton Room 105 Lab ID-Version‡: 22063088-1
Sample Layers Asbestos Content White Compound with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: G26-048-2, Drywall & Joint Compound (w/Texture)- Central Cubicle Area Lab ID-Version‡: 22063089-1
Sample Layers Asbestos Content White Drywall with Brown Paper and Paint ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: G26-048-3, Drywall & Joint Compound (w/Texture)- Central Cubicle Area Lab ID-Version‡: 22063090-1
Sample Layers Asbestos Content White Compound with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: G26-048-4, Wall Texture, Orange Peel- Hamilton Room 105 Lab ID-Version‡: 22063091-1
Sample Layers Asbestos Content White Texture with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 2 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-5, Wall Texture, Orange Peel- Hamilton Room 105 Lab ID-Version‡: 22063092-1
Sample Layers Asbestos Content White Texture with Paint ND
Sample Composite Homogeneity: Good
Location: G26-048-6, Wall Texture, Orange Peel- Central Cubicle Area Lab ID-Version‡: 22063093-1
Sample Layers Asbestos Content White Texture with Red Paint ND
White Texture with Peach Paint ND White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: G26-048-7, Sink Undercoating, Gray- Hamilton Room 105 Lab ID-Version‡: 22063094-1
Sample Layers Asbestos Content Gray Sink Undercoating ND
Sample Composite Homogeneity: Good
Location: G26-048-8, Sink Undercoating, Gray- Hamilton Room 105 Lab ID-Version‡: 22063095-1
Sample Layers Asbestos Content Gray Sink Undercoating ND
Sample Composite Homogeneity: Good
Location: G26-048-9, Glue, Tan, Under Carpet Tiles- Kalapuya Room 110 Lab ID-Version‡: 22063096-1
Sample Layers Asbestos Content Tan Mastic ND
Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 3 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-10, Glue, Tan, Under Carpet Tiles- Central Cubicle Area Lab ID-Version‡: 22063097-1
Sample Layers Asbestos Content Tan Mastic ND
Sample Composite Homogeneity: Good
Location: G26-048-11, Cove Base, 4" Black and Cream Adhesive- West Hallway Lab ID-Version‡: 22063098-1
Sample Layers Asbestos Content Black Cove Base ND
White Mastic ND Sample Composite Homogeneity: Good
Location: G26-048-12, Cove Base, 4" Black and Cream Adhesive- Central Cubicle Area Lab ID-Version‡: 22063099-1
Sample Layers Asbestos Content Black Cove Base ND
Tan Mastic ND Sample Composite Homogeneity: Good
Location: G26-048-13, Drywall w/Skimcoat- Kalapuya Room 110 Lab ID-Version‡: 22063100-1
Sample Layers Asbestos Content White Powdery Material with Paint ND White Drywall with Brown Paper ND
Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 4 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-14, Drywall w/Skimcoat- Training Room 115 Lab ID-Version‡: 22063101-1
Sample Layers Asbestos Content White Powdery Material with Paint ND White Drywall with Brown Paper ND
Sample Composite Homogeneity: Good
Location: G26-048-15, Drywall w/Skimcoat- Janitorial Closet Lab ID-Version‡: 22063102-1
Sample Layers Asbestos Content White Powdery Material with Paint ND White Drywall with Brown Paper ND
Sample Composite Homogeneity: Good
Location: G26-048-16, Leveling Compound, White- West Hallway Lab ID-Version‡: 22063103-1
Sample Layers Asbestos Content White Leveling Compound ND
Tan Mastic ND Sample Composite Homogeneity: Good
Location: G26-048-17, Leveling Compound, White- West Hallway Lab ID-Version‡: 22063104-1
Sample Layers Asbestos Content White Leveling Compound ND
Tan Mastic ND Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 5 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-18, Sink Undercoating, Light Gray- Break Room 111 Lab ID-Version‡: 22063105-1
Sample Layers Asbestos Content Pink Sink Undercoating 3% Chrysotile
Sample Composite Homogeneity: Moderate
Location: G26-048-19, Sink Undercoating, Light Gray- Break Room 111 Lab ID-Version‡: 22063106-1
Sample Layers Asbestos Content Pink Sink Undercoating 3% Chrysotile
Sample Composite Homogeneity: Moderate
Location: G26-048-20, Leveling Compound, Gray- Central Cubicle Area Lab ID-Version‡: 22063107-1
Sample Layers Asbestos Content Gray Leveling Compound with Tan Mastic ND
Sample Composite Homogeneity: Good
Location: G26-048-21, Leveling Compound, Gray- Central Cubicle Area Lab ID-Version‡: 22063108-1
Sample Layers Asbestos Content Gray Leveling Compound ND
White Compound with Tan Mastic ND Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 6 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-22, Floor Tile, 12x12, Cream and Black Mastic- West Hallway (2nd Layer) Lab ID-Version‡: 22063109-1
Sample Layers Asbestos Content Yellow Mastic ND
Cream Floor Tile ND Black Mastic 3% Chrysotile
Sample Composite Homogeneity: Good
Location: G26-048-23, Floor Tile, 12x12, Cream and Black Mastic- West Hallway (2nd Layer) Lab ID-Version‡: 22063110-1
Sample Layers Asbestos Content Yellow Mastic ND
Cream Floor Tile ND Black Mastic 3% Chrysotile
Sample Composite Homogeneity: Good
Location: G26-048-24, Floor Tile, 12x12 Light Gray w/White and Dark Gray Specks, and Tan Glue- Break Room 111 Lab ID-Version‡: 22063111-1
Sample Layers Asbestos Content Light Gray Floor Tile ND
Tan Mastic ND Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 7 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-25, Floor Tile, 12x12 Light Gray w/White and Dark Gray Specks, and Tan Glue- Break Room 111 Lab ID-Version‡: 22063112-1
Sample Layers Asbestos Content Semi-Transparent Mastic (Trace) ND
Light Gray Floor Tile ND Tan Mastic (Trace) ND
Sample Composite Homogeneity: Good
Location: G26-048-26, Floor Tile, 12x12, Gray w/Light and Dark Gray Specks, and Brown Glue- Mechanical Room 112 Lab ID-Version‡: 22063113-1
Sample Layers Asbestos Content Gray Floor Tile ND Brown Mastic ND
Sample Composite Homogeneity: Good
Location: G26-048-27, Floor Tile, 12x12, Gray w/Light and Dark Gray Specks, and Brown Glue- Mechanical Room 112 Lab ID-Version‡: 22063114-1
Sample Layers Asbestos Content Gray Floor Tile ND Brown Mastic ND
Sample Composite Homogeneity: Good
Location: G26-048-28, Duct Seam Tape, White- Mechanical Room 112 Lab ID-Version‡: 22063115-1
Sample Layers Asbestos Content White Tape ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Good
EMLab ID: 4399356, Page 8 of 19Eurofins Built Environment Testing West, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-048; 139 4th Ave SE. Albany, OR 97321
Date of Sampling: 02-02-2026 Date of Receipt: 02-02-2026 Date of Report: 02-05-2026
ASBESTOS PLM REPORT
Location: G26-048-29, Duct Seam Tape, White- Mechanical Room 112 Lab ID-Version‡: 22063116-1
Sample Layers Asbestos Content White Tape ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Good
Location: G26-048-30, Glue, Tan, Under Black Carpet- West Hallway, South Entrance Lab ID-Version‡: 22063117-1
Sample Layers Asbestos Content Tan Mastic ND
Sample Composite Homogeneity: Good
Location: G26-048-31, Glue, Tan, Under Black Carpet- Front Entrance Lab ID-Version‡: 22063118-1
Sample Layers Asbestos Content Tan Mastic ND
Gray Leveling Compound ND White Leveling Compound ND
Sample Composite Homogeneity: Good
Location: G26-048-32, Ceiling Tile, 2x4, G+P- Kalapuya Room 110 Lab ID-Version‡: 22063119-1
Sample Layers Asbestos Content…