Attachment E-1 ACM LBP Salem.pdf

PDF 7 MB Posted

Attached to
Oregon Employment Department LED Lighting Upgrade Project
Solicitation number
S-DASOBO-00017609
Issued by
Oregon

About this file

This is an Attachment E-1 document related to Asbestos-Containing Material (ACM) and Lead-Based Paint (LBP) assessment for the Oregon Employment Department LED Lighting Upgrade Project, involving the Oregon Department of Administrative Services (DAS) State Property and Services (SPS) on behalf of the Oregon Employment Department (OED). The document outlines the identification and documentation of ACM and LBP conditions at the project site in Salem, Oregon. The assessment serves as a critical prerequisite for the LED lighting upgrade work, establishing baseline conditions and compliance requirements that must be addressed during construction. The project scope includes all labor, materials, transportation, equipment, permits, and services necessary for completion of the lighting upgrade construction work, with particular attention to proper handling, abatement, and documentation of any hazardous materials encountered.

The document provides detailed findings regarding the presence or absence of ACM and LBP at the facility, which directly impacts project costs, scheduling, and contractor qualifications. Any identified hazardous materials require specialized handling and licensed contractors certified in ACM and LBP abatement, potentially increasing project expenses and timeline. Contractors submitting bids for this project must review and acknowledge the ACM and LBP assessment findings to ensure compliance with federal and state regulations, including proper notification, containment, removal, and disposal procedures. The baseline conditions documented in this attachment establish the environmental requirements that all bidders must incorporate into their cost estimates and project planning for the LED lighting upgrade work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Comprehensive Asbestos Survey & LBP Inspection Purpose: Pre-Renovation & Operations and Maintenance

Client:

Oregon Employment Department 875 Union Street NE Salem, Oregon 97311

Project:

PO#: 159417 - WorkSource Salem 605 Cottage Street NE Salem, Oregon 97301

G2 Project #: G26-052

February 26, 2026

Prepared By:

G2 Consultants 7312 SW Durham Road Portland, Oregon 97224 888-998-4224 www.g2ci.com

CCB#: 253530

http://www.g2ci.com

Comprehensive Asbestos Survey & LBP Inspection G2 Consultants Project #: G26-052

Purpose of Inspection: Pre-Renovation & Operations and Maintenance

Scope of Inspection: Comprehensive - Interiors, Exteriors & Roofs

Project Description: WorkSource Salem

Project Address: 605 Cottage Street NE Salem, Oregon 97301

Owner or Facility Operator:

Oregon Employment Department 875 Union Street NE Salem, Oregon 97311

Owner or Facility Operator Phone #:

541-280-0482

Technical Certifications

Consultant Discipline Certification # Regulatory Agency Phone Number

Chase Eckersell Asbestos Building Inspector

IRO-25-9965B EPA 971-485-5469

Caleb Miltimore Lead-Based Paint Inspector

241886-Indv-I

915241886-I

OR Health Authority

OR CCB

971-464-8757

Page of 1 14

G2 Consultants | www.g2ci.com | 888-998-4224

Oregon Employment Department Comprehensive Asbestos Survey & Lead-Based Paint Inspection WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

Table of Contents

• Executive Summary

• Description of Structure(s)

• Scope of Inspection

• Inspection Findings

• Recommended Response Actions

• Methodology

• Limitations

Appendices

Appendix A: Asbestos Samples & Material Location Drawings

Appendix B: Laboratory Analysis Results & Chain of Custody

Appendix C: Photographs of Homogeneous Materials Sampled

Appendix D: XRF Readings Table

Appendix E: Performance Characteristic Sheet (PCS)

Appendix F: Certifications & Accreditation

Page of 2 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

G2 Consultants (G2) was retained by Oregon Employment Department (OED) to conduct a comprehensive building inspection for asbestos-containing materials (ACM) and lead-based paint (LBP). The survey was conducted at WorkSource Salem, located at 605 Cottage Street NE, in Salem, Oregon. The scope of the inspection was comprehensive, including all interior, exterior and roofing materials in anticipation of an upcoming renovation project, as specified by OED.

Authorization was provided by Christian Hargrove, Senior Construction Project Manager 2 with

OED.

Date(s) of Inspection: February 3, 2026

Purpose of Inspection: Pre-Renovation & Operations and Maintenance

Scope of Inspection: Comprehensive - All readily accessible interior, exterior and roofing suspect asbestos-containing materials and painted building components. However, destructive sampling techniques were not utilized to gain access to potentially hidden materials such as within wall cavities or other interstitial spaces, or if sampling would result in irreparable damage like with siding systems, mechanical systems, mirrors, ceramic tile, etc.

Asbestos Results of this limited survey have determined that materials listed in the following table are ACMs, containing asbestos in an amount greater than 1%:

NOTE: Friability listed is based on conditions at the time of G2’s survey. Materials may become friable if disturbed.

* The material locations and quantities provided, represents the areas within the scope of work only. It does not represent the potential location/quantity of materials throughout the site.

Executive Summary

Asbestos-Containing Materials Identified or Presumed - Overview

Material Description Material Location* Approx.

Quantity*

Condition Friable Y/N

Drywall and Joint Compound Throughout 39,450 sq. ft. Good Y

Mastic, Black, under Beige 12” x 12” Floor Tile

Women’s Lounge 118, Electrical Room 120, Stairway 121

432 sq. ft. Good N

2nd Layer Floor Tile, 12” x 12” Beige, and Black Mastic

Vestibule 122 40 sq. ft. Good N

Caulking, Dark Gray, around Exterior Soffits and Flashing

Exterior - Around Soffits and Flashing 1,196 lf. Good N

Floor Tile, 12” x 12” Beige, and Tan Glue

Mechanical Room 212 65 sq. ft. Good N

Composite Roofing Exterior - Roof 11,775 sq. ft. Good N

Drywall and Joint Compound (w/ Texture)

Women’s Lounge 118, Janitor’s Closet 211 575 sq. ft. Good Y

Page of 3 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

Details of the inspection, descriptions and locations of materials, quantities, condition and friability can be found in the following sections of this report.

Lead-Based Paint One interior paint film analyzed was determined to contain lead concentrations above the United States Housing and Urban Development (HUD) and EPA Renovation, Repair and Painting (RRP) threshold for LBP of 1.0 milligram per centimeter squared (mg/cm2).

Lead above the 1.0 mg/cm2 threshold was also identified in the enamel glazing of sinks and ceramic wall within the building.

Details of the inspection can be found in the following sections of this report, and in the XRF Readings Table found in Appendix D.

Page of 4 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

G2 was contracted by OED to conduct a comprehensive building inspection for ACM and LBP.

The survey was conducted at WorkSource Salem, located at 605 Cottage Street NE, in Salem, Oregon. The scope of the inspection was comprehensive, including all interior, exterior and roofing materials in anticipation of an upcoming renovation project, as specified by Christian Hargrove with OED. The sampling was conducted to represent all suspect materials within the scope of work.

Asbestos The scope of services was to perform a visual and tactile inspection, and identify the presence, quantity and location of the accessible ACM, within the area(s) of the scope of work. All identified

Description of Structure(s)

Type of facility: Commercial Office Past uses: Commercial Office Age of construction: 1963

Approximate square footage: 24,000 sq. ft.

Number of floors: Three

Outbuildings included in inspection: None Inaccessible rooms/areas: None

Aerial Photo of Subject Property Location of Subject Property

Scope of Inspection

Page of 5 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026 accessible suspect materials were sampled. The building was occupied and in operation at the time of the survey, therefore, destructive sampling techniques were not utilized to gain access to potentially hidden materials such as within wall cavities or other interstitial spaces, or if sampling would result in irreparable damage like with siding systems, mechanical systems, mirrors, ceramic tile, etc.

Lead-Based Paint The LBP inspection was performed in accordance with the U.S. Environmental Protection Agency Renovation, Repair and Painting Rule because it was conducted by a licensed LBP inspector using documented methodologies, such as those in Housing and Urban Development Guidelines Chapter 7 (2012 Edition), and the EPA RRP guidelines.

Readings of the lead content of painted components throughout the areas within the scope of work were collected using an X-Ray Fluorescence (XRF) device. The readings were taken from the predominant accessible interior and exterior paint films including surfaces coated with shellac, varnish, stain, etc., in order to provide a general indication of the distribution of lead. Ceramic tile and other non-paint surfaces (bath tubs, sinks, toilets, etc.) were tested for lead content due to the possibility of lead exposure during demolition or renovation activities. All Federal and State regulations governing the inspection of LBP were followed.

Other suspect ACMs and LBP may be present in the building that are outside this limited scope of work, or in areas that were not accessible at the time of the survey. Furthermore, the material locations and quantities provided in this report represents the accessible areas within the scope of work only. ACMs identified during this survey, if hidden or concealed, may potentially be located in additional rooms of the building, and at greater quantities than those stated in this report.

Asbestos Results of this limited survey have determined that materials listed in the following table are ACMs, containing asbestos in an amount greater than 1%:

Inspection Findings

Asbestos-Containing Materials Identified or Presumed

HM

No.†

Material Description Material Location* Approx.

Quantity*

No. of Samples

Asb. Type &

Condition Friable Y/N

1 Drywall and Joint Compound

Throughout 39,450 sq. ft. 9 Drywall - None Detected

Joint Compound - Chrysotile 2%

Good Y

Page of 6 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

NOTE: Friability listed is based on conditions at the time of G2’s survey. Materials may become friable if disturbed.

† - Homogeneous material number

* The material locations and quantities provided, represents the areas within the scope of work only. It does not represent the potential location/quantity of materials throughout the site.

Results of this limited survey have determined that materials listed in the following table do not contain asbestos in an amount greater than 1%:

22 Floor Tile, 12” x 12” Beige w/Brown and White Specks, and Black Mastic

Women’s Lounge 118, Electrical Room 120, Stairway 121

432 sq. ft. 2 Floor Tile - None Detected

Mastic - Chrysotile 5%

Good N

30 2nd Layer Floor Tile, 12” x 12” Beige, and Black Mastic

Vestibule 122 40 sq. ft. 2 Floor Tile - Chrysotile 2%

Mastic - Chrysotile 5%

Good N

34 Caulking, Dark Gray, around Exterior Soffits and Flashing

Exterior - Around Soffits and Flashing

1,196 lf. 2 Chrysotile 6% Good N

36 Floor Tile, 12" x 12" Beige, and Tan Glue

Mechanical Room

65 sq. ft. 2 Floor Tile - Chrysotile 3%

Glue - None Detected

Good N

37 Composite Roofing Exterior - Roof 11,775 sq. ft. 4 Chrysotile 2-5%

Good N

40 Drywall and Joint Compound (w/ Texture)

Women’s Lounge 118, Janitor’s Closet

575 sq. ft. 4 Drywall - None Detected

Joint Compound - Chrysotile 2%

Good Y

Asbestos-Containing Materials Identified or Presumed

HM

No.†

Material Description Material Location* Approx.

Quantity*

No. of Samples

Asb. Type &

Condition Friable Y/N

Non Asbestos-Containing Materials Identified

HM

No.†

Material Description Material Location* Asb. Type & % No. of Samples

2 Ceiling Tile, 2’ x 2’ Textured w/Pinholes Throughout None Detected 2

3 Wallpaper Adhesive, Beige Throughout None Detected 2

4 Cove Base, 4” Black, and Tan Adhesive Throughout None Detected 2

5 Glue, Green, under Carpet Tiles Throughout None Detected 2

6 Ceiling Tile, 2' x 2' Gouged w/Pinholes Throughout None Detected 2

Page of 7 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

7 Vinyl Plank Flooring, Faux Wood Pattern Break Room 208, Janitorial Closet 211

None Detected 2

8 2nd Layer Sheet Vinyl, Blue Pebble Pattern, and Tan Glue

Break Room 208, Janitorial Closet 211

None Detected 2

9 Grout and Mortar, Gray, from 1” x 1” Ceramic Floor Tile

1st Floor Public Restrooms, 2nd Floor Public Restrooms, 2nd Floor Staff Restrooms

None Detected 2

10 Grout, Cream, and Adhesive, Tan, from 4” x 4” Beige Ceramic Wall Tile

1st Floor Public Restrooms, 2nd Floor Public Restrooms, 2nd Floor Staff Restrooms

None Detected 2

11 Stair Tread, Tan, and Tan Glue Stairway 214 None Detected 2

12 Cove Base, 4” Tan, and Tan Adhesive Stairway 214 None Detected 2

13 Floor Tile, 12” x 12” Blue w/White Specks, and Tan Adhesive

Stairway 214, Vestibule 108 None Detected 2

14 Cove Base 4” Blue, and Tan Adhesive Stairway 214 None Detected 2

15 Stair Tread, Gray, and Tan Glue Stairway 214 None Detected 2

16 Glue, Tan, under Gray Carpet McKenzie Room 107 None Detected 2

17 Floor Tile, 12" x 12" Gray w/Light and Dark Gray Specks, and Tan Glue

Kitchen 114 None Detected 2

18 Sink Undercoating, Black Kitchen 114, Cedar Room 219 None Detected 2

19 Sheet Vinyl, Gray Pebble Pattern, and Yellow Glue Staff Men’s Restroom 116, Staff Women’s Restroom 117

None Detected 2

20 Grout, Cream, and Adhesive, Tan, from White 4” x 4” Ceramic Wall Tile

Staff Men’s Restroom 116, Staff Women’s Restroom 117

None Detected 2

21 Cove Base, 6” Black, and Tan Adhesive Staff Men’s Restroom 116, Staff Women’s Restroom 117

None Detected 2

23 Cove Base, 4" Brown, and Brown Adhesive Lounge 118, Electrical Room

None Detected 2

24 Pipe Insulation Hard Fittings Throughout None Detected 3

25 Glue, Tan, under Black Carpet Vestibule 100, Vestibule 122 None Detected 2

26 Stair Tread, Black, and Tan Glue Front Entry Stairs None Detected 2

27 Duct Seam Compound, Gray Throughout None Detected 2

28A Wall Texture, Orange Peel (Women’s Lounge 118) Women’s Lounge 118 None Detected 3

28B Wall Texture, Orange Peel (Janitorial Closet 211) Janitorial Closet 211 None Detected 3

29 Residual Adhesive, Brown, behind Various Cove Base

Throughout None Detected 2

31 Leveling Compound, Gray Throughout None Detected 2

32 Wall Texture, Knockdown Mt. Hood Room, 223 None Detected 3

Non Asbestos-Containing Materials Identified

HM

No.†

Material Description Material Location* Asb. Type & % No. of Samples

Page of 8 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

† - Homogeneous material number

* The material locations provided, represents the areas within the scope of work only. It does not represent the potential locations/quantities of materials throughout the site.

Details of the samples collected, including locations of individual samples can be found in Appendix B: Laboratory Analysis Results & Chain of Custody.

Lead-Based Paint The types of components listed in the table below indicate the presence of lead at or above the EPA RRP and HUD Guidelines action level. The EPA and HUD definition of “positive” LBP is lead equal to or greater than 1.0 mg/cm2. Additional details including reading number, floor, substrate, side, color and lead content details are located in the XRF Readings Table found in Appendix D.

NOTE: Readings in the table noted as LBP, are paint films with lead concentrations at or above 1.0 mg/cm2.

Readings in the table noted as Positive, are non-painted surfaces, such as ceramic tile, with lead concentrations at or above 1.0 mg/cm2

Per HUD guidelines, for each era of construction to be inspected, all testing combinations in each room equivalent were identified and tested by XRF. A testing combination is characterized by the room equivalent, the component type, and the substrate. A room equivalent is an identifiable part of a building (room, exterior, foyer, etc.). Painted surfaces include any surface coated with paint, shellac, varnish, stain, paint covered by wallpaper, or any other coating. Wallpaper was assumed to cover paint unless building records or physical evidence indicated no paint was present. At least one individual XRF reading was collected on each testing combination in each room equivalent. For walls, at least four readings were collected (one reading on each wall) in each room equivalent. A different visible color does not by itself result in a separate testing combination.

33 Stucco Exterior - Siding None Detected 5

35 Caulking, Tan, around Exterior Windows and Doors Exterior - Around Windows and Doors

None Detected 2

38 Sealant, Gray, around Roof Penetrations Exterior - Roof Penetrations None Detected 2

39 Sealant, Black w/Residual White Caulking, around Roof Penetrations

Exterior - Roof Penetrations None Detected 2

Non Asbestos-Containing Materials Identified

HM

No.†

Material Description Material Location* Asb. Type & % No. of Samples

Testing Combinations with Lead Equal to or Greater than 1.0 mg/cm2

Site Address Structure Component Room Equivalent Substrate Condition Result

605 Cottage Street NE, Salem, OR

Main Building Sink Janitorial Closet

Enamel Intact Positive

Main Building Wall Tile Restrooms Ceramic Intact Positive

Main Building Sink Restrooms Enamel Intact Positive

Main Building Divider Restrooms Wood Intact LBP

Page of 9 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

According to HUD Guidelines Chapter 7, if one testing combination (i.e. window, door) is positive for lead in an interior or exterior room equivalent, then all other similar testing combinations in those areas are also assumed to be positive for lead.

The XRF testing was conducted using an XRF lead paint analyzer. A surface-by-surface visual assessment of the painted and/or finished surfaces was conducted to determine which lead-coated surfaces/components are deteriorated at or above de minimis levels, specifically, the EPA’s minor repair and maintenance activities thresholds (40 CFR § 745.83). The EPA de minimis thresholds apply to work that disrupts: (a) 6 square feet or less of painted surface per room for interior activities; or (b) 20 square feet or less of painted surface for exterior activities; provided that none of the work practices prohibited or restricted by 40 CFR § 745.85(a)(3) were used and where the work does not involve window replacement or demolition of painted surface areas.

EPA regulations define deteriorated paint as, “any interior or exterior paint or other coating that is peeling, chipping, chalking or cracking, or any paint or coating located on an interior or exterior surface or fixture that is otherwise damaged or separated from the substrate" (40 CFR § 745.63).

Asbestos

Results of the limited survey have determined that the drywall and joint compound throughout;

the black mastic under beige floor tile in Women’s Lounge 118, Electrical Room 120, and Stairway 121; the floor tile and black mastic under the carpet in Vestibule 122; the dark gray caulking around exterior soffit and flashing; beige floor tile in Mechanical Room 212; and the composite roofing material are ACMs. All materials were observed to be in good condition at the time of the survey.

If any untested suspect materials are encountered during renovation activities, they should be assumed to be ACM and not disturbed, unless sampling and analysis of the materials proves otherwise.

Friability is determined by whether a material can be crumbled, pulverized or reduced to a powder by pressure of an ordinary human hand. The friability of materials listed in this report are based on the present state and actual conditions of the materials observed at the time of G2’s survey.

Materials listed as non-friable can become friable through impact or damage.

All identified and presumed ACM must be removed by a licensed asbestos abatement contractor, or other certified individual, prior to impact if they are to be disturbed during renovation activities. ACM remaining in the building should be managed in good

Recommended Response Actions

Asbestos-Containing Materials (ACM)

Any building material which contains asbestos in an amount greater than 1% is considered an ACM by the United States Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA), and by the State of Oregon Department of Environmental Quality (DEQ) and the Oregon Occupational Safety and Health Division (OR-OSHA).

Page of 10 14

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026 condition, under an Operations and Maintenance Plan, and checked regularly for damage.

OR-OSHA requires a variety of actions when ACM is present in a commercial structure. These include labelling, warning signs, hazard communication and periodic inspections. All of the requirements of a building owner/operator with regard to asbestos can be found in Oregon Administrative Rules (OAR) 437, Division 2.

Any ACM likely to be disturbed during renovation or demolition activities, other than by incidental contact with no generation of debris related to other construction activities, should be abated by a licensed asbestos abatement contractor. Any activities conducted where the primary object of the activity is the removal of ACM must be conducted by a licensed asbestos abatement contractor or other properly trained individuals.

The National Emissions Standards for Hazardous Air Pollutants (NESHAPs) requires that all Regulated Asbestos-Containing Materials (RACMs) be removed from a building prior to demolition.

No materials were identified during this survey that contained 1% or less asbestos.

Many of the engineering controls and work practices required by the EPA and OSHA are applicable only to materials that contain greater than 1% asbestos. However, OSHA has established work practice requirements and prohibitions that apply when asbestos is present in any quantity, and/or whenever worker exposure exceeds the PEL, regardless of the amount of asbestos in the materials involved. Applicable requirements for materials that contain 1% or less asbestos can be found in the OSHA Asbestos Construction Standard 29 CFR 1926.1101.

Lead-Based Paint LBP was identified on one interior painted component analyzed, with lead concentrations above 1.0 mg/cm2. The LBP film in the building was observed to be in intact condition at the time of the inspection.

Lead above the 1.0 mg/cm2 threshold was also identified in the enamel glazing of sinks and ceramic wall tile within the building.

Lead-containing paint (LCP), paint films with lead concentrations greater than zero but less than

1.0 mg/cm2, may be present on other painted surfaces. The presence/absence of LCP cannot be confirmed via XRF analysis.

LBP and LCP films could create lead dust or lead contaminated soil hazards if the paint is turned to dust by abrasion, scraping or sanding. If conditions of intact paint surfaces become destabilized, these conditions will need to be addressed. All paint films in poor condition must be stabilized if the structure is to be demolished.

Asbestos-Containing Materials - 1% Asbestos or Less

Any building material which contains asbestos in an amount of 1% or less is considered asbestos-containing by OSHA and OR-OSHA. Although these materials are not considered ACMs, workers must be protected from exposure to asbestos, regardless of the percentage.

Page of 11 14

G2 Consultants | www.g2ci.com | 888-998-4224 https://osha.oregon.gov/OSHARules/div2/div2Z-1001-asbestos.pdf https://osha.oregon.gov/OSHARules/div2/div2Z-1001-asbestos.pdf

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

If any construction or modernization work is done on the premises, contractors and other personnel who may impact these materials should be informed of the results of this inspection. The Occupational Safety and Health Administration (OSHA) and Oregon OSHA (OR-OSHA) have requirements for employees working with or around LBP and LCP.

LBP is a common cause of lead poisoning in children and represents a threat to the health and welfare of the occupants. Where economically feasible, it is our recommendation that all components that tested positive, and any similar untested components, be considered lead-laden, and lead-safe procedures is incorporated into any overall renovation and maintenance strategy in order to reduce the potential for contamination and/or exposure. Safe methods include: containing any work area to prevent dispersal of lead dust and chips, wet sanding and scraping at a minimum; collecting all paint chips and debris and, properly disposing of them.

Details of the locations and lead content for all of the readings can be found in Appendix D: XRF Readings Table.

If additional painted surfaces are discovered that were not tested as part of this inspection, or that are expected to be impacted as part of any renovation or demolition work, they should be presumed LBP until tested to show otherwise.

A risk assessment has not been conducted to evaluate potential lead hazards present at the building and surrounding soil as part of this scope of work.

Asbestos The field work was conducted using industry best practices. Samples of representative accessible suspect materials within the scope of work were collected during the course of the inspection.

Materials were sampled according to homogeneous groupings using the Asbestos Hazard Emergency Response Act (AHERA) sampling guidelines.

Asbestos samples were collected in such a manner as to minimize release of the material into the surroundings. Sample number, material description, sample location and material location were recorded at the time of sampling. Each sample was placed in a sample container labeled with a unique sample number and submitted to a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory, for analysis under chain of custody documentation. Samples were analyzed in accordance with EPA Method 600/R-93-116, using PLM with dispersion staining and using visual area estimation to determine percent asbestos content. This method allows for the identification of the primary types of asbestos used in building materials. The lower limit of detection for this method is one percent. Samples containing one percent or less asbestos by PLM with visual area estimation are reported as “Trace”.

Lead-Based Paint All testing of suspect LBP was conducted utilizing a SciAps X-ray fluorescence LBP analyzer, Model X550Pb (Rh) bearing Serial #01583. The device uses a rhodium X-ray fluorescence tube as

Methodology

Page of 12 14

G2 Consultants | www.g2ci.com | 888-998-4224 https://www.epa.gov/sites/production/files/documents/2003pt763_0.pdf https://www.epa.gov/sites/production/files/documents/2003pt763_0.pdf

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026 opposed to a radioactive source. G2 followed the Performance Characteristics Sheets (PCS) for the specific X-Ray fluorescence instrument used during the LBP evaluation of the property. The XRF PCS is presented in Appendix E. The instrument was calibrated to the manufacturer's specifications and was also periodically verified against the National Institute of Standards and Testing (NIST) Standard Reference Material (SRM) 2579 lead film (1.0 mg/cm2).

The calibration of the instrument is conducted in accordance with the PCS for this instrument.

These instruments are calibrated using a calibration standard block of known lead content. If for any reason the instruments do not maintain a consistent calibration reading within the manufacturer’s standards for performance on the calibration block supplied by the manufacturer, manufacturer’s recommendations are used to bring the instrument into calibration. If the instrument cannot be brought back into calibration, it is taken off the site and sent back to the manufacturer for repair and/or re-calibration.

Wall “A” in each room is the wall where the front entrance door opening is located (or aligned with street). Going clockwise and facing Wall “A,” Wall “B” will always be to your right, Wall “C” directly to the rear and Wall “D” to the left. Doors, windows and closets may be designated as left, center or right depending on their location on the wall. Doors, windows, and closets are designated as left, center or right depending on their location on the wall.

All individuals who performed this XRF testing and visual assessment have EPA and/or state licenses as Lead Inspector/Risk Assessors and have been trained in the use, calibration and maintenance of the XRF, along with the principles of radiation safety, in accordance with the work practices of 40 CFR 745, section 227, for states and Native American tribal groups.

G2 has performed this inspection in accordance with best industry methods and practices of the profession, and consistent with the level of care and skill ordinarily exercised by reputable environmental consultants under similar circumstances and conditions. The observations contained within this assessment are based upon site conditions readily accessible at the time of the site inspection. No other representation, guarantee or warranty, express or implied, is included or intended in this hazardous materials survey report.

The LBP portion of the inspection was planned, developed, and implemented based on G2’s professional experience in performing LBP inspections. G2 performed a limited inspection for lead-containing paint of the predominant painted surfaces in order to provide a general indication of the distribution of lead for demolition purposes. G2 utilized state-of-the-art practices and techniques in accordance with regulatory standards while performing this inspection. A copy of personnel and company certifications has been provided in Appendix F. G2’s evaluation of the painted surfaces identified during this inspection is based on conditions observed at the time of the inspection. G2 cannot be responsible for changing conditions that may alter the relative exposure risk for future changes in accepted methodology.

Limitations

Page of 13 14

G2 Consultants | www.g2ci.com | 888-998-4224 http://www.epa.gov/EPA-TOX/2001/January/Day-05/t84.pdf

WorkSource Salem - 605 Cottage Street NE, Salem, OR February 26, 2026

The owner is responsible to convey information regarding identified lead content to inhabitants, contractors, etc. expected to potentially be exposed. G2 recommends that both the contractor and the owner keep the records for three years.

This report consists of a visual survey, and XRF analysis of the readily accessible areas of this building and tested components. The presence or absence of LBP or LBP hazards applies only to the tested or assessed surfaces on the date(s) of the field visit and it should be understood that conditions may change due to deterioration or maintenance. The results and material conditions noted within this report were accurate at the time of the evaluation and in no way reflect the conditions at the property after the date of the evaluation.

As with all environmental investigations, this inspection is limited to the defined scope and does not purport to set forth all hazards, nor indicate that other hazards do not exist.

Respectfully submitted and reviewed by:

Chase EckersellAndrew Lutz
Project Manager IDirector of Operations
G2 ConsultantsG2 Consultants

Page of 14 14

Appendix A:

Asbestos Samples & Material

Location Drawings

Samples in RED are asbestos-containing materials.

* indicates sample should be considered asbestos-containing based on results of other samples of the material

Samples not shown: 5*, 82-85, 86-89

41-45

3*

94* 4*

77*

2-26-26

B ui ld in g:

Fl oo r:

D w g Ty pe

CE

1/2

This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.

Report North

W or kS ou rc e

S al em 1s t F lo or S am pl e Lo ca tio ns

C lie nt

P ro je ct

Lo ca tio n:

O re go n

E m pl oy m en t D ep ar tm en t

C om pr eh en si ve A sb es to s

S ur ve y

C ot ta ge

S tre et N

E S al em

, O re go n

G

P ro je ct

G

-0

C lie nt

P ro je ct

Lo ca tio n:

C lie nt

P ro je ct

Lo ca tio n:

N ot es

7312 SW Durham Road Portland, Oregon 97224

888.998.g2ci www.g2ci.com

Samples in RED are asbestos-containing materials.

* indicates sample should be considered asbestos-containing based on results of other samples of the material

Samples not shown: 5*, 82-85, 86-89

1*

2*

92*

96*

91*

95*

2-26-26

B ui ld in g:

Fl oo r:

D w g Ty pe

CE

2/2

This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.

Report North

W or kS ou rc e

S al em 2n d Fl oo r

S am pl e

Lo ca tio ns

C lie nt

P ro je ct

Lo ca tio n:

O re go n

E m pl oy m en t D ep ar tm en t

C om pr eh en si ve A sb es to s

S ur ve y

C ot ta ge

S tre et N

E S al em

, O re go n

G

P ro je ct

G

-0

C lie nt

P ro je ct

Lo ca tio n:

C lie nt

P ro je ct

Lo ca tio n:

N ot es

7312 SW Durham Road Portland, Oregon 97224

Black Mastic under Floor Tile, 12" x 12" Beige w/Brown and White Specks

2nd Layer Floor Tile, 12" x 12" Beige, and Black Mastic

Drywall and Joint Compound

Materials Not Shown: Caulking, Dark Gray, around Exterior Soffits and Flashing Floor Tile, 12" x 12" Beige, and Tan Glue

Composite Roofing

2-26-26

B ui ld in g:

Fl oo r:

D w g Ty pe

CE

1/2

This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.

Report North

W or kS ou rc e

S al em 1s t F lo or A

C M

L oc at io ns

C lie nt

P ro je ct

Lo ca tio n:

O re go n

E m pl oy m en t D ep ar tm en t

C om pr eh en si ve A sb es to s

S ur ve y

C ot ta ge

S tre et N

E S al em

, O re go n

G

P ro je ct

G

-0

C lie nt

P ro je ct

Lo ca tio n:

C lie nt

P ro je ct

Lo ca tio n:

N ot es

7312 SW Durham Road Portland, Oregon 97224

Floor Tile, 12" x 12" Beige, and Tan Glue

Drywall and Joint Compound

Materials Not Shown: Caulking, Dark Gray, around Exterior Soffits and Flashing Composite Roofing Black Mastic under Floor Tile, 12" x 12" Beige w/Brown and White Specks 2nd Layer Floor Tile, 12" x 12" Beige, and Black Mastic

2-26-26

B ui ld in g:

Fl oo r:

D w g Ty pe

CE

2/2

This is a design drawing and is the property of G2 Consultants. It is not intended to replace required architectual or engineering plans. This drawing is not to be reused or reproduced without written permission from G2 Consultants.

Report North

W or kS ou rc e

S al em 2n d Fl oo r

A C

M L oc at io ns

C lie nt

P ro je ct

Lo ca tio n:

O re go n

E m pl oy m en t D ep ar tm en t

C om pr eh en si ve A sb es to s

S ur ve y

C ot ta ge

S tre et N

E S al em

, O re go n

G

P ro je ct

G

-0

C lie nt

P ro je ct

Lo ca tio n:

C lie nt

P ro je ct

Lo ca tio n:

N ot es

7312 SW Durham Road Portland, Oregon 97224

Appendix B:

Laboratory Analysis Results

& Chain of Custody

Approved by:

Approved Signatory Rebecca Kelly

Report for:

Chase Eckersell G2 Consultants 17750 SW Upper Boones Ferry Rd Suite 150 Portland, OR 97224

Regarding:

Eurofins Built Environment Testing West, LLC Project: G26-052; 605 Cottage St. NE Salem, OR 97301

EML ID: 4403143

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing West, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 02-09-2026

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 101920-0

EMLab ID: 4403143, Page 1 of 25Eurofins Built Environment Testing West, LLC

Eurofins Built Environment Testing West, LLC 7619 6th Ave NW, Seattle, WA 98117

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Total Samples Submitted: 89 Total Samples Analyzed: 89

Total Samples with Layer Asbestos Content > 1%: 12

Location: G26-052-1, Drywall and joint compound; Cedar room 219 Lab ID-Version‡: 22084544-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound ND Composite Non-Asbestos Content: 10% Cellulose

2% Glass Fibers Sample Composite Homogeneity: Moderate

Location: G26-052-2, Drywall and joint compound; Stairway 214 Lab ID-Version‡: 22084545-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

Composite Non-Asbestos Content: 10% Cellulose 2% Glass Fibers

Sample Composite Homogeneity: Good

Location: G26-052-3, Drywall and joint compound; Kitchen 114 Lab ID-Version‡: 22084546-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound with Paint ND

Composite Non-Asbestos Content: 10% Cellulose 2% Glass Fibers

Sample Composite Homogeneity: Moderate

EMLab ID: 4403143, Page 2 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Location: G26-052-4, Drywall and joint compound; Electrical room 120 Lab ID-Version‡: 22084547-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND White Joint Compound with Paint ND

Composite Non-Asbestos Content: 10% Cellulose 2% Glass Fibers

Sample Composite Homogeneity: Moderate

Location: G26-052-5, Drywall and joint compound; Basement Lab ID-Version‡: 22084548-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound ND Composite Non-Asbestos Content: 10% Cellulose

2% Glass Fibers Sample Composite Homogeneity: Moderate

Location: G26-052-6, Ceiling Tile, 2x2, textured w/ pinholes; Cedar room 219 Lab ID-Version‡: 22084549-1

Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 65% Cellulose 25% Glass Fibers

Sample Composite Homogeneity: Good

Location: G26-052-7, Ceiling Tile, 2x2, textured w/ pinholes; McKenzie room 107 Lab ID-Version‡: 22084550-1

Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 65% Cellulose 25% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 4403143, Page 3 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Location: G26-052-8, Wallpaper adhesive, beige; Cedar room 219 Lab ID-Version‡: 22084551-1

Sample Layers Asbestos Content Off-White Wallpaper ND

Beige Adhesive ND Off-White Texture ND

Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose

5% Synthetic Fibers Sample Composite Homogeneity: Moderate

Location: G26-052-9, Wallpaper adhesive, beige; Open office space 207 Lab ID-Version‡: 22084552-1

Sample Layers Asbestos Content Off-White Wallpaper ND

Beige Adhesive ND Brown Paper ND

Composite Non-Asbestos Content: 10% Cellulose 5% Synthetic Fibers

Sample Composite Homogeneity: Moderate

Location: G26-052-10, Cove base, 4" black and tan adhesive; Cedar room 219 Lab ID-Version‡: 22084553-1

Sample Layers Asbestos Content Black Cove Base ND

Tan Mastic ND Sample Composite Homogeneity: Moderate

Location: G26-052-11, Cove base, 4" black and tan adhesive; McKenzie room 107 Lab ID-Version‡: 22084554-1

Sample Layers Asbestos Content Black Cove Base ND

Tan Mastic ND Sample Composite Homogeneity: Moderate

EMLab ID: 4403143, Page 4 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Location: G26-052-12, Glue, green, under carpet tiles; Open office space 207 Lab ID-Version‡: 22084555-1

Sample Layers Asbestos Content Green Glue ND Tan Glue ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: G26-052-13, Glue, green, under carpet tiles; Open office space 106 Lab ID-Version‡: 22084556-1

Sample Layers Asbestos Content Green Glue ND Tan Glue ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: G26-052-14, Ceiling tile, 2x2, G+P; Open office space 207 Lab ID-Version‡: 22084557-1

Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 70% Cellulose 20% Glass Fibers

Sample Composite Homogeneity: Good

Location: G26-052-15, Ceiling tile, 2x2, G+P; Open office space 207 Lab ID-Version‡: 22084558-1

Sample Layers Asbestos Content Tan Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 70% Cellulose 20% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 4403143, Page 5 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Location: G26-052-16, Vinyl plank flooring, faux wood; Break room 208 Lab ID-Version‡: 22084559-1

Sample Layers Asbestos Content Gray Sheet Flooring with Fibrous Backing ND

Tan Mastic ND Composite Non-Asbestos Content: 15% Cellulose

5% Glass Fibers Sample Composite Homogeneity: Moderate

Location: G26-052-17, Vinyl plank flooring, faux wood; Janitors closet 211 Lab ID-Version‡: 22084560-1

Sample Layers Asbestos Content Gray Sheet Flooring with Fibrous Backing ND

Yellow Mastic ND Composite Non-Asbestos Content: 10% Synthetic Fibers

5% Glass Fibers Sample Composite Homogeneity: Moderate

Location: G26-052-18, Sheet vinyl, blue pebble pattern and tan glue; Break room 208 Lab ID-Version‡: 22084561-1

Sample Layers Asbestos Content Brown Flooring ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: G26-052-19, Sheet vinyl, blue pebble pattern and tan glue; Janitors closet 211 Lab ID-Version‡: 22084562-1

Sample Layers Asbestos Content Brown Flooring ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4403143, Page 6 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(833) 465-5857 www.eurofinsus.com/Built Client: G2 Consultants C/O: Chase Eckersell Re: G26-052; 605 Cottage St. NE Salem, OR 97301

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

ASBESTOS PLM REPORT

Location: G26-052-20, Grout and mortar, gray, from 1"x1", ceramic floor tile; Mens restoom 2/3 Lab ID-Version‡: 22084563-1

Sample Layers Asbestos Content Off-White Ceramic Tile ND

Gray Grout ND Tan Mortar ND

Sample Composite Homogeneity: Moderate

Location: G26-052-21, Grout and mortar, gray, from 1"x1", ceramic floor tile; Mens restroom 230 Lab ID-Version‡: 22084564-1

Sample Layers Asbestos Content Off-White Ceramic Tile ND

Gray Grout ND Brown Paper ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: G26-052-22, Grout, cream, and adhesive, tan from 4"x4" beige ceramic wall tile; Mens restroom 230 Lab ID-Version‡: 22084565-1

Sample Layers Asbestos Content White Ceramic Tile ND

Cream Grout ND Tan Adhesive ND

Tan Drywall with Brown Paper ND Composite Non-Asbestos Content: 5% Cellulose

1% Glass Fibers Sample Composite Homogeneity: Moderate

EMLab ID: 4403143, Page 7 of 25Eurofins Built Environment Testing West, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .