Attachment D RFB 758 2700000016 - MT0126_outside_overhead_fascia_dualroller.pdf
PDF 402 KB Posted
- Attached to
- Lodge Room Window Treatments for Blue Licks SRP
- Solicitation number
- RFB 758 2700000016 2
- Issued by
- Kentucky
About this file
This is a technical submittal drawing for a FlexShade FMO small dual roller outside-mount overhead shade system, identified as Order No. MT0126, prepared by Draper. The drawing provides standard installation details for a motorized roller shade with external fascia and dual roller configuration, designed for integration with glass curtain wall and ceiling systems. The document includes a parts list specifying blocking by others, fasteners by others, motor tube, spline roller, shade fabric, and hem pocket components. The drawing utilizes layered CAD files to allow project-specific adaptations and includes dimensional specifications in both inches and millimeters for shade height, bundle diameter (maximum 23/4 inches or 69.9mm), and installation clearances (11 16/32 inches or 42.1mm). The submittal is accompanied by user notes directing installers to manipulate drawing layers within editing software for customization purposes.
Draper reserves the right to discontinue or modify the product without notice. Installation requirements specify minimum 2x wood blocking (2-3/4 inches plywood or equivalent 2x lumber) positioned between framing and finished ceiling, or alternatively minimum 18-gauge flat sheet steel or similar material. The blocking and fasteners are designated as items to be provided by others, with Draper responsible for supplying the motor tube, spline roller, shade fabric, and hem pocket. No pricing information, contract terms, response deadlines, funding sources, or procurement-related details are contained within this technical submittal document.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SH
EET:
O F:
O R
D
ER
N O
JOB NAME:
LOCATION:
DEALER:
MODEL:
SUBMITTAL DATE:
DRAWN:
REVISED:
REVISED:
AS BUILT:
M T0
6:
F
LE
XS
HA
DE
D
FM
O
S m al l D ua l R ol le r E nd ca p
F as ci a
R eg ul ar
R ol l / / O ut sid e M ou nt
(O ve rh ea d)
PARTS LIST
DESCRIPTIONITEM
1 Blocking By Others per Note 3 at Left 2 Fasteners By Others
Motor
Tube, Spline Roller Shade Fabric
GLASS CURTAIN WALL
CEILING
Hem Pocket
USER NOTE: WE HAVE USED DRAWING LAYERS TO MAKE THESE STANDARD DETAILS EASIER TO ADAPT TO YOUR PROJECT SPECIFIC DETAILS. YOU CAN TURN OFF/ON LAYERS WITHIN YOUR EDITING SOFTWARE.
WINDOW SILL
VERTICAL MULLION
NOTES: UNLESS OTHERWISE SPECIFIED.
1. DRAPER RESERVES THE RIGHT TO DISCONTINUE OR MODIFY ANY PRODUCT WITHOUT NOTICE
2. ALL DIMENSIONS ARE IN INCHES [mm].
3. BLOCKING BY OTHERS: DRAPER RECOMMENDS MIN 2X WOOD BLOCKING (2-3/4" [69.9] PLYWD OR 2X) OR MIN 18 GA FLAT SHEET STEEL OR SIM. IF WOOD, BLOCKING SHOULD BE BETWEEN FRAMING AND FINISHED CEILING.
16 [176.1mm]
SHADE HEIGHT
4 [120.1mm]
Ø23 4 [Ø69.9mm]MAX
BUNDLE DIAMETER
Ø23 4 [Ø69.9mm]MAX
BUNDLE DIAMETER
16 [42.1mm]
File details come from the government source that posted it. Updated .