This document appears to be a set of installation notes for a card reader system at a federal facility. The key details are:

The installation notes describe the requirements for cabling, electrical boxes, and control panel enclosures for the card reader system. All cabling must be blue CAT-6 and run in conduit. Single gang electrical boxes and Lenel control panel enclosures will be used. The facility uses Lenel 1300 boards rather than the 1320 boards pictured. Reviewers should ensure there is adequate space in the communication closets for the new control boards.

This installation appears to be part of a larger federal contract opportunity, Solicitation Number 36C26124R0058, to upgrade entrance doors, install canvas canopies, and add a concrete gutter at Buildings 6 and 7 for the Department of Veterans Affairs Southern Nevada Health Care System. The contract opportunity is a task order request under the VISN 21 Multiple Award Construction Contract. A site visit is scheduled for June 11, 2024, and questions should be submitted to the identified Contract Specialist and Contracting Officer.

View the file

Other files

File Type Posted
ISON IAHP1 LED.pdf PDF
IMG 0206.jpeg JPEG file
100264 EP 301B.pdf PDF
RFI finalized.docx DOCX document
36C26124R0058 0003.docx DOCX document
087113.pdf PDF
100264 EP 301A.pdf PDF
Hanbook 0023.pdf PDF
SOW Revised.pdf PDF
VA Signage Info.pdf PDF
36C26124R0058 0002.docx DOCX document
36C26124R0058 0001.docx DOCX document
Attachment 593-24-102_Combined Drawings.pdf PDF
Attachment WMC Form Ktr Employee Sponsor Request.pdf PDF
Attachment ENG_FORM_4288-R.pdf PDF
Attachment 240117_SOP for PIV Badging Process.docx DOCX document
Attachment Badging Checklist-sample.xlsx XLSX spreadsheet
Attachment 593-24-102 SOW.pdf PDF
Attachment FM1A_Contract Security Service Request.pdf PDF
Attachment 593-24-102 Combined Specifications.pdf PDF
Attachment 5 List of Bid Items.pdf PDF
Attachment Price Proposal_Breakdown.docx DOCX document
36C26124R0058_1 Solicitation.docx DOCX document
Attachment VSC FM OF 306 Declaration of Fed Empl.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASIC ONE LINE DRAWING FOR CARD READER INSTALLATIONS

INSTALLATION NOTES:

1. All cabling will be encased running down any wall and will be encased to the nearest cable tray.

If less than 6’ it may be flex, if over 6’ it must be rigid EMT.

2. All cabling will be blue CAT-6 as a minimum and will be pulled and terminated at the identified IT closet. All Access cabling will be white.

3. Single gang electrical boxes (metal) shall be used at each card reader location and door controller location.

4. Lenel box (size: xx” X xx” X xx” deep with lock) will be used for the 1300 door controller board and for the 3300 control board locations as needed.

5. This facility uses LENEL 1300 boards instead of 1320 as pictured below. All new card reader additions shall include a review of the closest Comm closet as to insure there is room in the control panels. If needed, new control boards will be included with the install.