Attachment C.pdf
PDF 73 KB Posted
- Solicitation number
- SCS-FD-PD-FURNITURE-2025
- Issued by
- Macomb County, Michigan
About this file
This document is a Room Finish Schedule and Wall Types specification sheet for the City of St. Clair Shores New Fire Headquarters project located at 26700 Harper Ave in St. Clair Shores, Michigan. The detailed architectural drawing provides comprehensive information about room finishes, wall construction types, and surface treatments for various rooms within the new fire station, including specific specifications for floor materials, wall surfaces, base treatments, and ceiling finishes for each room numbered from 101 to 253.
The document includes extensive technical details about partition series, wall construction methods, fire ratings, and acoustic performance requirements. Room finishes range from carpet (CPT) and luxury vinyl tile (LVT) to exposed painted concrete and specialized epoxy-painted surfaces, particularly in functional areas like the apparatus bay, decontamination room, and hot zones. The specification sheet provides precise instructions for wall construction, including metal stud spacing, gypsum board requirements, insulation specifications, and fire-rated partition guidelines, with particular attention to sound attenuation and fire safety considerations for different areas within the fire station.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment A.pdf | ||
| Attachment H.pdf | ||
| Attachment B.pdf | ||
| Attachment E.pdf | ||
| PD-FD-Furniture-Specs-2025.pdf | ||
| Attachment D.pdf | ||
| Attachment F.pdf | ||
| Attachment G.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A PARTITION�SERIES�'A'
1"�=�1'-0"
7�5/8"
UNDERSIDE�OF�FLOOR�OR�ROOF
REFER�TO�STRUCTURAL�FOR�
REQUIRED�CONNECTION
CEILING�AS�SCHEDULED
-�CONCRETE�MASONRY�-�REFER
TO�STRUCTURAL�FOR�REINFORCING
BASE�AS�SCHEDULED
11�5/8"
5�5/8"
3�5/8"
0A12
0A8
0A6
0A4
UL�U906
UL�U905
UL�U905
1A6
1A8
1A12
GROUT�MASONRY�WALL�
TOP�COURSE�SOLID
PARTITION�SERIES�'B'
1"�=�1'-0"
-�5/8"�GYP.�BOARD�(BOTH�SIDES)
-�MTL.�STUDS�@�16"�OC
-�FIBER�BATT�ACOUSTICAL�INSULATION
(NOTE:�USE�IMPACT�RESISTANT�
GYP�AT�ALL�CORRIDORS)
CEILING�AS�SCHEDULED
BASE�AS�SCHEDULED
B
4" �M
IN
3�5/8"�MTL.�KICKERS�TO�UNDERSIDE�
OF�ROOF�TRUSS�ABOVE�@�32"�O.C.
DEFLECTION�TRACK,�TYP.�3/4"�
STRUCT.�DEFLECTION�ALLOWANCE.
0B3
0B2
4�7/8"
UL�U419
0B4
0B6
5�1/4"
7�1/4"
1B3
1B2
1B4
1B6
UL�U419
UL�U419
UL�U419
METAL�RUNNER�CHANNEL�
(SECURED�TO�FLOOR)
SEALANT�(BOTH�SIDES)
3�3/4"
(WHERE�GYP�DOES�NOT�
GO�TO�DECK�ABOVE)
UNDERSIDE�OF�FLOOR�OR�ROOF
-�5/8"�GYP.�BOARD�
-�MTL.�FURRING�CHANNEL�@�16"�OC
(NOTE:�USE�IMPACT�RESISTANT�
GYP�AT�ALL�CORRIDORS)
M
IN4"
0F1
0F0
0F2
0F3
3�1/8"
4�1/4"
1�1/2"
2�1/4"
FACE�OF�WALL�CONSTRUCTION�
REFER�TO�PLAN
UNDERSIDE�OF�FLOOR�OR�ROOF
CEILING�AS�SCHEDULED
BASE�AS�SCHEDULED
METAL�RUNNER�CHANNEL�
(SECURED�TO�FLOOR)
SEALANT
PARTITION�SERIES�'F'
1"�=�1'-0"F
GENERAL�NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
A.
B.
C.
D.
"WALL"�AND�"PARTITION"�ARE�USED�TO�DENOTE�EITHER�WALLS�OR�PARTITIONS�AND�ARE�USED�
INTERCHANGEABLY
REFER�TO�STRUCTURAL�FOR�ALL�REQUIRED�REINFORCING�AND�FOR�WALL�CONNECTIONS�TO�
FLOORS�AND�ROOFS
AT�FIRE�RATED�WALLS�FILL�ALL�VOIDS,�PENETRATIONS�ETC.�AND�SEAL�-�REFER�TO�DRAWING�
A0-02�LIFE�SAFETY�PLANS�&�CODE�INFORMATION�FOR�ALL�PARTITION�FIRE�RATINGS
WHERE�A�WALL�RUNS�PARALLEL�TO�THE�DIRECTION�OF�A�ROOF�TRUSS�AND�DOES�NOT�ALIGN�
UNDERNEATH�A�TRUSS�-�PROVIDE�MTL.�STUD�BRIDGING�BETWEEN�THE�ROOF�TRUSSES�@�48"�
O.C.�MAX.�TO�ATTACH�TO
REFER�TO�ROOM�FINISH�SCHEDULE�FOR�WALL�FINISHES�AND�WAL�BASE
PARTITION�TYPE
SUBSTITUTE�TILE�BACKING�BOARD�AT�LOCATIONS�TO�RECEIVE�A�TILE�WALL�FINISH
ALL�NON-LOAD�BEARING�METAL�WALL�FRAMING�SHALL�BE�BASED�ON�TOTAL�STUD�HEIGHT
AT�INTERSECTIONS�OF�DIS-SIMILAR�PARTITION�TYPES,�THE�HIGHEST�RATED�PARTITION�IS�TO�
RUN�THROUGH�THE�INTERSECTION�TO�MAINTAIN�ENCLOSURE
FIRE-RATED�PARTITIONS�SHALL�BE�CONSTRUCTED�ACCORDING�TO�THE�FIRE�TEST�INDICATED.�
NO�SUBSTITUTIONS�OF�MATERIALS�OR�DEVIATIONS�FROM�CONSTRUCTION�ARE�ALLOWED.�
ADDITIONAL�LAYERS�MAY�BE�REQUIRED�FOR�ACOUSTICAL�OR�OTHER�REASONS�AND�MUST�BE�
EXECUTED�AS�SHOWN
STC�RATINGS�ARE�MINIMUM�ACOUSTICAL�PERFORMANCE�REQUIREMENT.�SPECIFIC�
ACOUSTICAL�TESTS�ARE�GIVEN�FOR�REFERENCE�ONLY.�SOUND�ATTENUATION�BLANKET�
THICKNESS�SHALL�BE�AS�FOLLOWS:
1�1/2"�FOR�PARTITIONS�WITH�1�5/8"�AND�2�1/2"�STUDS�(INCLUDING�SHAFTWALLS)
3"�FOR�PARTITIONS�WITH�3�5/8",�4"�OR�6"�STUDS�UON
3"�FOR�SHAFTWALLS�WITH�4"�OR�6"�STUDS�UON
AS�REQUIRED�FOR�FIRE�RATING
12. AT�ALL�FIRE�RATED�WALL�CONSTRUCTION,�PROVIDE�SIGNAGE�ABOVE�THE�ADJACENT�
ACCESSIBLE�CEILING�THAT�STATES:�"FIRE�AND/OR�SMOKE�BARRIER�-�PROTECT�ALL�OPENINGS."� THE�LETTERS�ARE�TO�BE�3"�HIGH�MIN.�AND�ARE�TO�BE�STENCILED�IN�PAINT�DIRECTLY�ONTO� THE�WALL.�LOCATE�THE�SIGNS� 30'-0"�O.C.�MAXIMUM.�AND�NO�MORE�THAN�15'-0"�FROM�THE�
END�OF�EACH�WALL.�[703.7]
GRAPHIC�TAG
#X#
PARTITION�SERIES
SIZE�DESIGNATOR�
(SEE�TABLE�BELOW)
S=SMOKE�PARTITION
0=NON�RATED
1=1-HR�FIRE�RATED
2=2-HR�FIRE�RATED
3=30�MIN�FIRE�RATED
ASSEMBLY�RATING
MATERIAL DESIGNATION�SIZE ACTUAL�SIZE
3�5/8" 5�5/8" 7�5/8" 11�5/8"
SPACING
1�5/8" 2�1/2" 3�5/8" 4" 6"
MASONRY
STEEL�STUDS
FURRING 0
7/8" 1�5/8" 2�1/2" 3�5/8"
SHAFTWALL
C-H�STUDS
2�1/2" 4" 6"
N/A
16"�OC
16"�OC
24"�OC
ROOM�FINISH�LEGEND
AF ATHLETIC�FLOORING
ACT ACOUSTIC�TILE�AND�GRID�CEILING�SYSTEM
CONC CONRETE
CPT CARPET
CT CERAMIC�TILE
EP EPOXY�FLOORING
EP�PNT EPOXY�PAINT
LVT LUXURY�VINYL�TILE�FLOORING
PC EXPOSED�PRECAST�CONCRETE�PLANK�CEILING
PT PORCELAIN�TILE
PNT PAINT
RB RESILIENT�WALL�BASE
SS SOLID�SURFACING
VCT VINYL�COMPOSITION�TILE
MP FORMED�METAL�CEILING�PANEL
ROOM�FINISH�GENERAL�NOTES
A.
B.
C.
REFER�TO�REFLECTED�CEILING�PLANS,�INTERIOR�ELEVATIONS,�AND�FINISH�FLOOR�PLANS�FOR�LOCATIONS�OF�MATERIAL�/�PAINT�
TRANSITIONS.
REFER�TO�MATERAL�FINISH�&�COLOR�SCHEDULE,�SPECIFICATION�SECTION�000200.
PROVIDE�REDUCER�STRIP�AT�FLOOR�MATERIAL�TRANSITIONS�AS�NEEDED,�REFER�TO�THRESHOLD�DETAILS�AND�DOOR�SCHEDULE.
ROOM�FINISH�KEY�NOTES
1. NOTE
PARTNERS�in�Architecture,�PLCPARTNERS�in�Architecture,�PLC
DRAWN�BY
CHECKED�BY
Statement�of�Intellectual�Property
65�Market�Street Mount�Clemens,�MI�48043 P�586.469.3600 F�586.469.3607
PROJECT�NO.
APPROVED�BY
PROJECT�NAME
OWNER
SHEET�NAME
KEY�PLAN
ISSUES�/�REVISIONS
SHEET�NO.
CONSULTANT
The�ideas,�concepts,�drawings�and�thoughts�conveyed� herein�are�the�intellectual�property�of�PARTNERS�in� Architecture,�PLC,�65�Market�Street,�Mount�Clemens,�MI,� 48043�(P586.469.3600).�This�set�of�drawings,�in�whole�or� in�part,�may�not�be�reproduced,�without�the�written�consent� of�PARTNERS�in�Architecture,�PLC.�This�information�is� protected�under�U.S.�Copyright�Law,�all�rights�reserved.
©�Copyright�2024
NORTH
PARTNERS
THIS�DRAWING�IS�NOT�TO�BE�USED�FOR�
CONSTRUCTION�UNLESS�ISSUED�BELOW�
SPECIFICALLY�FOR��"CONSTRUCTION"
6/14/2024�4:22:44�PM D:\_revit local\23�147�SCS�FD�Central�CD_DGwozdzDHM3H.rvt A0-04
City�of�St.�Clair�Shores
SCS�New�Fire Headquarters
DJG
DJG
23-147
26700�Harper�Ave St�Clair�Shores,�MI�48081
DG
Room�Finish Schedule,�Wall�Types, Signage
Room�Finish�Schedule
ROOM
NO. ROOM�NAME FLOOR BASE
WALLS
CEILING ROOM�FINISH�KEY�NOTESNORTH EAST SOUTH WEST
101 VESTIBULE CPT-1 RB-1 -- PNT-1 PNT-1 PNT-1 ACT-1
102 LOBBY RTF-1,2,3 RB-1 PNT PNT PNT PNT EXPOSED�-�PNT-X
103 RECEPTION CPT-2,3 RB-1 PNT-1 PNT-4 PNT-1 PNT-1 ACT-1
104 OFFICE CPT-4 RB-1 PNT-1 PNT-4 PNT-1 PNT-1 ACT-1
105 CHIEF'S�OFFICE CPT-4 RB-1 PNT-1 PNT-4 PNT-1 PNT-1 ACT-1
106 CORRIDOR CPT-2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
107 CONFERENCE CPT-4,5,6 RB-1 PNT-1 PNT-4 PNT-1 PNT-1 ACT-1
108 CODE�LIBRARY CPT-2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
109 STAIR PC-1�/�SN-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
110 AIRLOCK PC-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
111 HOT�ZONE PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
112 WC PT-1 CT-1 CT-2,3�/�PNT-1 CT-2,3�/�PNT-1 CT-2,3�/�PNT-1 CT-2,3�/�PNT-1 PNT-2
113 ELEC PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
114 OFFICE CPT-4 RB-1 PNT-1 PNT-1 PNT-1 PNT-4 ACT-1
115 EMS PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
116 OFFICE CPT-4 RB-1 PNT-1 PNT-1 PNT-1 PNT-4 ACT-1
117 TOOL�ROOM PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
118 OFFICE CPT-4 RB-1 PNT-1 PNT-1 PNT-1 PNT-4 ACT-1
119 JC PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
120 WC PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
121 HOT�ZONE PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
122 WC PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
123 AIRLOCK PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
124 IT/AV CPT-4 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
125 TRAINING CPT-4,5,6 RB-1 PNT-1,5�/�ST-1 PNT-1,5�/�ST-1 PNT-1,5�/�ST-1 PNT-1,5�/�ST-1 ACP-1�/�PNT-X
126 IT PC-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
127 UTILITY�(WATER) PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
150 APPARATUS�BAY PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
160 ELEC PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EXPOSED�-�PNT-X
161 DECON PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 PNT-X
162 BATH�/�SHOWER PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 PNT-X
163 LAUNDRY PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 PNT-X
164 PPE PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 PNT-X
165 SCBA PC-1 RB-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 EP-PNT-1 PNT-X
201 DAYROOM RTF-1,2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACP-1�/�PNT-X
202 DINING�ROOM PT-2 PT-3 PNT-1 PNT-1 PNT-1�/�PNT-4 PNT-1 ACP-1�/�PNT-X
203 KITCHEN PT-2 PT-3 CT�/�PNT-1 CT�/�PNT-1 PNT-1�/�PNT-4 PNT-1 ACP-1�/�PNT-X
204 PANTRY RUBBER RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
205 STOR CPT-2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
206 BC�OFFICE CPT-2,3 RB-1 PNT-1 PNT-1 PNT-4 PNT-1 ACT-1
207 STOR RTF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
208 WC PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
210 LAUNDRY�/�JC PC-1 RB-1 CT-2�/�PNT-1 CT-2�/�PNT-1 CT-2��/�PNT-1 CT-2��/�PNT-1 ACT-1
211 CORRIDOR RTF-1,2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
212 REPORT�/�UNION RTF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
213 BATHROOM PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
214 BATHROOM PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
215 BATHROOM PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
216 BATHROOM PT-1 -- PT-4 PT-4 PT-4 PT-4 PNT-2
217 BC�DORM CPT-2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
218 DORMITORY CPT-2,3 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACP-1�/�PNT-X
219 STOR RTF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
220 STOR RTF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1
250 MEZZANINE SC-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
251 FITNESS RAF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 PNT-X
252 STOR RAF-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
253 COMPRESSOR�/�STOR SC-1 RB-1 PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED�-�PNT-X
100%�SD 04/18/24
95%�DD�-�Owner�Review 06/07/24
100%�DD 06/14/24
Rayes Typewriter Attachment C (1 of 1) Reference Use Only
File details come from the government source that posted it. Updated .