Attachment B Swinging Fire Door Assemblies rev 1.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
Annual Inspection of Fire Doors and Quarterly Penetration Inspection of Fire and Smoke Barriers
Solicitation number
36C24426Q0670
Issued by

About this file

This is an attachment listing the swinging fire door assemblies and smoke barrier doors required for inspection and maintenance at a Department of Veterans Affairs facility. The spreadsheet inventories 118 door assemblies and 96 door frames distributed across multiple floors and buildings (Floors 1-11 and Ground Level), including stairwells, elevator lobbies, mechanical rooms, corridors, and specialized areas such as operating rooms, clinics, and vaults. The doors are classified by fire barrier rating (primarily 2-hour and 1-hour ratings) and smoke barrier designation, with specific room locations and identification numbers provided for each installation point. The majority of entries require one door and one frame per location, with select locations requiring two or more doors, such as double corridor doors and elevator lobby entrances. This inventory serves as the basis for the annual inspection of fire doors and quarterly penetration inspection of fire and smoke barriers solicitation (36C24426Q0670) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4, ensuring comprehensive coverage of all fire-rated and smoke-barrier door assemblies throughout the facility for compliance and safety purposes.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

BuildingFloorLocationFire Barrier RatingQty DoorsQty Frames
111Elevator machine room - East211
111Elevator machine room - Northwest211
111Elevator machine room - West211
19Stair 1211
19Passage 9010221
18Stair 1211
18Stair 5211
18Stair 7211
18Stair 4 - East Mechanical Room211
18Stair 8 - West Mechanical Room211
17Stair 1211
17Stair 5211
17Stair 7211
17Stair 4 - East Mechanical Room211
17Stair 8 - West Mechanical Room211
16Stair 1211
16Stair 5211
16Stair 7211
15Stair 1211
15Stair 5211
15Stair 7211
155E double corrior doorsSmoke21
155035111
15Corridor door by 5043Smoke11
155W double doors to eye clinic121
14Stair 1211
14Stair 5211
14Stair 7211
144E Lobby Corridor DoorsSmoke21
144050121
144053111
144050/4060111
144W Lobby Corridor DoorsSmoke21
13Stair 1211
13Stair 2211
13Stair 5211
13Stair 7211
133018111
133019111
133023111
133024111
13East Corridor double doors by 3009Smoke21
133055Smoke11
133056Smoke11
133064111
133065111
133067111
133072111
13Door between 3078/3078ASmoke11
133001 - Double door to OR CorridorSmoke21
13Clinical Addition Elevator Lobby - West Side221
13Clinical Addition Elevator Lobby - East Side221
12Stair 1211
12Stair 2211
12Stair 3211
12Stair 5211
12Stair 7211
12Clinical Addition Elevator LobbySmoke21
122006211
12East Corridor double door by 2006221
122055 - South Door211
122055 - East Door211
11Stair 1211
11Stair 2211
11Stair 3211
11Stair 5211
11Stair 7211
111152111
111176 Corridor Double door by main lobby121
111076 corridor double door to police dispatchSmoke21
111400 corridor double door by 1406 (hold open doors)Smoke21
111407Smoke11
111408Smoke11
11East Corridor double door outside 1074121
1GStair 5211
1G143 - North doors to vault from corridor121
1G143 - South doors to vault from corridor121
1G145121
1G203211
1GStair 1 - Elevator Lobby211
1GStair 1 - Door to corridor 209211
1GDoor from 207 to 209211
1G209-210 North door211
1G209-210 South door211
1GStair 2211
1G244211
1GStair 7 - Corridor Side211
1GStair 7 - Valet Side211
17GBy 182221
17GFrom PT corridor to 184 chapel211
17GNew lobby to CLC Corridor211
17G5211
17G5A211
17G28111
17GBy W-21Smoke21
17GBy E-15Smoke21
11896