Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

SITE MAP GENERAL NOTES

PROFESSIONAL SEAL

APPLICABLE CODES & REGULATIONS

AERIAL PHOTOGRAPH OF EXISTING CONDITIONS

DRAWING INDEX

100%

CONSTRUCTION

DOCUMENT

11/12/2025

G001

COVER SHEET

100%

CONSTRUCTION

DOCUMENT

STATE OF KANSAS

PARSONS STATE HOSPITAL & TRAINING CENTER

AIR COOLED CHILLER REPLACEMENT

2601 GABRIEL AVE, PARSONS, KS, 67357

BUILDING NUMBER 5700-00020

X-1496

• 2018 INTERNATIONAL BUILDING CODE (IBC)

• 2018 INTERNATIONAL RESIDENTIAL CODE (IRC)

• 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)

• 2018 INTERNATIONAL MECHANICAL CODE (IMC)

• 2018 INTERNATIONAL PLUMBING CODE (IPC)

• 2018 INTERNATIONAL FUEL CODE (IFGC)

• INTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2006 EDITION OR ASHRAE 90.1-2007

• 2017 NFPA 70, NATIONAL ELECTRICAL CODE (NEC)

• KANSAS STATE BOILER CODE (K.S.A 22-913 ET SEQ)

TRUE

NORTH

TRUE

NORTH

HICKORY

COTTAGE

HICKORY

COTTAGE

00 - GENERAL

G001 COVER SHEET

23 - MECHANICAL

M000 MECHANICAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES

MD100 MECHANICAL - DEMO PLAN BASEMENT

MD101 MECHANICAL - DEMO PLAN LEVEL 1

M100 MECHANICAL - NEW WORK PLAN BASEMENT

M101 MECHANICAL - NEW WORK PLAN LEVEL 1

M500 MECHANICAL - DETAILS

M600 MECHANICAL - SCHEDULES

26 - ELECTRICAL

E000 ELECTRICAL POWER NOTES, LEGENDS & ABBREVIATIONS

ED100 ELECTRICAL POWER - DEMO PLAN BASEMENT

E100 ELECTRICAL POWER - NEW WORK PLAN BASEMENT

Total sheets: 11

Lisa Akagi - Introba LDA PE KS Seal Signed

M

M

M

S

T

P

M

M

T

DPSL H

T

T

DPT

T

AVG

T T

FS

MECHANICAL ABBREVIATIONS

ACU AIR CONDITIONING UNIT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AL ACOUSTIC LINING

ARCH ARCHITECT/ARCHITECTURAL

ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING

AND AIR-CONDITIONING ENGINEERS

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

AW ACID WASTE

BLDG BUILDING

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BOS BOTTOM OF STEEL

BRD BAROMETRIC RELIEF DAMPER

CAV CONSTANT AIR VOLUME

CC COOLING COIL

CDW CONDENSER WATER

CFM CUBIC FEET PER MINUTE

CHW CHILLED WATER

CLG CEILING

CBC CALIFORNIA BUILDING CODE

CH CHILLER

CI CAST IRON

CT COOLING TOWER

CU COPPER

CL CENTERLINE

COL COLUMN

CONC CONCRETE

CONT CONTINUATION

CW COLD WATER

DB DRY BULB

DH DEHUMIDIFIER

DIM DIMENSION

DIA DIAMETER

DN DOWN

DWG DRAWING

(E) EXISTING

(ER) EXISTING TO BE RELOCATED

EAT ENTERING AIR TEMPERATURE

EF EXHAUST FAN

EL ELEVATION

ELEC ELECTRICAL

ET EXPANSION TANK

EW EMERGENCY EYEWASH

EWT ENTERING WATER TEMPERATURE

EXH EXHAUST

(F) FUTURE

FCU FAN COIL UNIT

FD FIRE DAMPER

FFE FINISHED FLOOR ELEVATION

FLR FLOOR

FM FLOW METER

FOB FLAT ON BOTTOM

FOT FLAT ON TOP

FPM FEET PER MINUTE

FS FLOW SWITCH

FSD COMBINATION FIRE SMOKE DAMPER WITH ACCESS

FT FEET

GPM GALLONS PER MINUTE

GR GRADE

GV GRAVITY VENTILATOR

HC HEATING COIL

HHW HEATING HOT WATER

HORIZ HORIZONTAL

HVAC HEATING, VENTILATING AND AIR CONDITIONING

HW HOT WATER

HX HEAT EXCHANGER

ID INSIDE DIAMETER

IN. INCHES

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LWT LEAVING WATER TEMPERATURE

LB POUND WEIGHT

MAX MAXIMUM

MFR MANUFACTURER

MIN MINIMUM

(N) NEW

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NG NATURAL GAS

NO NORMALLY OPEN

NPT NATIONAL PIPE THREAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OPNG OPENING

P PUMP

POC POINT OF CONNECTION

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIA PSI - ABSOLUTE

PSIG PSI - GAUGE

PVC POLYVINYL CHLORIDE

QTY QUANTITY

(R) REMOVE

RA RETURN AIR

RAH RECIRC AIR HANDLER

RC REHEAT COIL

REF ROOF EXHAUST FAN

SA SUPPLY AIR / SOUND ATTENUATOR

SC SCRUBBER

SCFM STANDARD CUBIC FEET PER MINUTE

SCHD SCHEDULE

SD SMOKE DETECTOR

SF SUPPLY FAN

SIM SIMILAR

SMACNA SHEET METAL AND AIR CONDITIONING

CONTRACTORS NATIONAL ASSOCIATION

SMEF SMOKE EXHAUST FAN

SPEC(S) SPECIFICATION(S)

SS STAINLESS STEEL

ST SOUND ATTENUATOR TRAP

STD(S) STANDARD(S)

TA TRANSFER AIR

TE TEMPERATURE ELEMENT

TEMP TEMPERATURE

TI TEMPERATURE INDICATOR

TOS TOP OF STEEL

TYP TYPICAL

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

V VOLTS

VAV VARIABLE AIR VOLUME

VB VACUUM BREAK

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VTR VENT THROUGH ROOF

VVR VARIABLE VOLUME UNIT WITH REHEAT

W WIDTH

W/O WITHOUT

WB WET BULB

WH WATER HEATER

WLD WELDED

WT WEIGHT

M6.02

DETAIL DESIGNATION

SHEET NUMBER

CH

EQUIPMENT TYPE

EQUIPMENT NUMBER

REVISION CLOUD AND DELTA

POINT OF DISCONNECTION

POINT OF CONNECTION

SYMBOLS AND

ANNOTATION

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE GAS

PRESSURE REDUCING VALVE - LINE

FEED

2-WAY CONTROL VALVE, 2-POS

2-WAY CONTROL VALVE, MODULATING

3-WAY CONTROL VALVE, 2-POS

3-WAY CONTROL VALVE, MODULATING

BALL VALVE

BUTTERFLY VALVE

BUTTERFLY VALVE W/OPERATOR

CHECK VALVE

CIRCUIT SETTER

DRAIN VALVE

FLOAT VALVE

T&P RELIEF VALVE

THERMOSTATIC MIXING VALVE

VALVE

WYE STRAINER

WAY STRAINER WITH BLOW OFF

MANUAL AIR VALVE

PLUG VALVE

SOLENOID VALVE

VALVES AND HYDRONIC

ACCESSORIES

CW DOMESTIC COLD WATER

CHWS CHILLED WATER SUPPLY

CHWR CHILLED WATER RETURN

RSL REFRIGERANT SUCTION LINE

RLL REFRIGERANT LIQUID LINE

PIPE DROP

PIPE RISE

PIPE BRANCH RISE

PIPE BRANCH DROP

PIPE BRANCH TEE

PIPE TEE RISE

PIPE TEE DROP

CAPPED PIPE

TEMP GUAGE

PRESSURE GUAGE

UNION

FLEX CONNECTOR

PETES PLUG

VACUUM BREAKER

PIPE GUIDE

PIPE ANCHOR

PIPE LINE DESIGNATIONS

PIPE

CONTROL VALVES & ACTUATORS

SENSORS

MOTORIZED ACTUATOR, 2 POSITION

MOTORIZED ACTUATOR, MODULATING

THERMOSTATIC ACTUATOR

AUTOMATIC AIR VENT

BTU METERTEMPERATURE SENSOR

TEMPERATURE SENSOR WITH

THERMOWELL

TEMPERATURE SENSOR AVERAGING

HYDRONIC FLOW METER

PUMP

HEAT EXCHANGER

PRESSURE TRANSDUCER

HYDRONIC EQUIPMENT (DIAGRAMS)

HYDRONIC LEVEL SENSOR

DIFFERENTIAL PRESSURE SENSOR

AIR COOLED CHILLER

PLANT EQUIPMENT

CPFEXPANSION TANK AIR SEPARATOR

FLOW SWITCH

MECHANICAL LEGEND

- BALL VALVE 2 1/2" AND BELOW

- BUTTERFLY VALVE 3" AND ABOVE

SHUT-OFF VALVE TYPE

CIRCUIT SETTER

BTU METER

EXISTING / DEMOLITION

EXISTING EQUIPMENT, DUCT, PIPE

EXISTING PIPE TO BE REMOVED

EXISTING DUCT OR EQUIPMENT

TO BE REMOVED

NEW EQUIPMENT DUCT PIPE

MECHANICAL GENERAL NOTES

1. ALL EQUIPMENT, DUCTS, PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF

THE BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY

WEATHERPROOFED.

2. PENETRATIONS OF PIPES, CONDUITS, ETC. IN WALLS REQUIRING PROTECTED OPENINGS SHALL

BE FIRE STOPPED.

3. FIRE STOP MATERIAL SHALL BE A UL-LISTED ASSEMBLY APPROVED BY THE FIRE MARSHAL.

4. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL

ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST

TO THE OWNER.

5. ALL ELBOWS, FITTINGS, ETC., IN PIPING REQUIRED TO CLEAR ALL JOB OBSTRUCTIONS ARE NOT

NECESSARILY INDICATED. ALL NECESSARY TRANSITIONS, FITTINGS AND OFFSETS ARE

REQUIRED WHETHER SHOWN OR NOT.

6. BECAUSE OF THE LIMITED SPACE AVAILABLE TO INSTALL ALL OF THE MECHANICAL WORK,

COORDINATION BETWEEN THE VARIOUS TRADES IS OF THE UTMOST IMPORTANCE. SEE

SPECIFICATION 230100 FOR REQUIRED COORDINATION DRAWINGS.

7. THE CONTRACTOR SHALL COORDINATE STAGING AND SCHEDULING WITH THE OWNER'S

REPRESENTATIVE.

8. DEMOLISH ALL PIPING, EQUIPMENT, ETC., SHOWN TO BE REMOVED, IN ITS ENTIRETY,

INCLUDING ALL HANGERS AND SUPPORTS.

9. THE CONTRACTOR SHALL VERIFY ALL REFRIGERANT PIPING SIZING AND ROUTINGS WITH THE

EQUIPMENT MANUFACTURER. THE CONTRACTOR SHALL ALSO PROVIDE ALL REQUIRED

REFRIGERANT ACCESSORIES AS RECOMMENDED BY THE EQUIPMENT MANUFACTURER FOR

COMPLETE AND FULLY FUNCTIONAL SYSTEMS

10. THE CONTRACTOR SHALL CONNECT THE NEW PORTION OF THE CHILLED WATER SYSTEM TO

THE OWNER'S EXISTING BUILDING CONTROL SYSTEM. REFER TO THE SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

11. REFRIGERANT SERVICE PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE

TAMPER RESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS BY AN

ACCEPTABLE MEANS.

12. THE OWNER SHALL MAINTAIN ALL SALVAGE RIGHTS OF EQUIPMENT AND MATERIALS REMOVED.

ALL EQUIPMENT AND MATERIALS NOT CLAIMED BY THE OWNER SHALL BE REMOVED FROM THE

PREMISES BY THIS CONTRACTOR.

13. HYDRONIC PIPING SHALL COMPLY WITH CHAPTER 12 OF THE 2018 INTERNATIONAL

MECHANICAL CODE.

14. PRIOR TO PERMIT BEING FINALIZED, A COMPLETE REPORT OF THE TESTING AND ADJUSTING

SHALL BE PROVIDED TO THE OWNER OR OWNER’S REPRESENTATIVE AND FACILITIES

OPERATOR AND FORM TESTING AND ADJUSTING SHALL BE COMPLETED AND PROVIDED TO THE

INSPECTOR.

15. PRIOR TO PERMIT BEING FINALIZED, A COMPLETE REPORT OF THE COMMISSIONING PROCESS

SHALL BE PROVIDED TO THE OWNER OR OWNER'S REPRESENTATIVE AND FACILITIES

OPERATOR, AND FORM VERIFICATION SHALL BE COMPLETED AND PROVIDED TO THE

INSPECTOR.

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

O F

A

D M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E N

T

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

C

M

P L

IA

N

C E

S

W

H

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

P

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

M000

MECHANICAL LEGEND,

ABBREVIATIONS, AND

GENERAL NOTES

X-1496

PE22870

12/19/2025

UP

BASEMENT

01B

(E) 4" CHWR TO REMAIN

(E) AHU. TO REMAIN

(E) HEAT EXCHANGER

(E) P-1

(E) 4" CHWS TO REMAIN

(E) 2" CHWR TO REMAIN

(E) 2" CHWS TO REMAIN

(E) 2" CHWS TO REMAIN

(E) 2" CHWR TO REMAIN

(E) 4" CHWS TO REMAIN

(E) 4" CHWR TO REMAIN

(E) RS

(E) RL

(E) 2-1/2" CHWS TO REMAIN

(E) 4" CHWS TO REMAIN

(E) 4" CHWS TO REMAIN

(E)3/4" CW FILL FROM

EXISTING BACKFLOW

PREVENTER

(E) EXPANSION TANK

TO REMIAN

(E) AIR SEPARATOR

4 (E) CHEMICAL FEED POT

TO REMIAN

(E) 2" CHWS TO REMAIN

(E) 3/4" CHWR TO REMAIN

(E) 4" CHWR

(E) 2" CHWR

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

MD100

MECHANICAL - DEMO PLAN

BASEMENT

X-1496

2'0' 1' 4'2'0' 1' 4'

1/4" = 1'-0"

MECHANICAL - DEMO - BASEMENT PLAN - DEMO

1. REMOVE EXISTING HEAT EXCHANGERS, ALL

REFRIGERANT PIPING, INSULATION, HANGERS,

VALVES, AND RELATED ACCESSORIES.

2. REMOVE EXISTING CHW CIRCULATING PUMP,

PIPING, INSULATION, HANGERS, VALVES AND

ALL RELATED ACCESSORIES.

3. REMOVE EXISTING AIR SEPARATOR, PIPING,

INSULATION, HANGERS, VALVES, AND ALL

RELATED ACCESSORIES.

4. EXISTING CHEMICAL TREATMENT FEEDER TO

REMAIN.

5. EXISTING EXPANSION TANK TO REMAIN.

6. CONNECT TO EXISTING COLD WATER LINE AND

BACKFLOW PREVENTER PREVIOUSLY

PROVIDING CW MAKE-UP FOR SYSTEM.

7. CONTRACTOR TO VERIFY EXACT LOCATION,

DUTY OF EXISTING PIPE, ELEVATION BEFORE

PROCEEDING WITH NEW WORK. CONTRACTOR

TO MAKE NECESSARY FIELD ADJUSTMENT TO

ACCOMPLISH SCOPE OF WORK SHOWN ON

DRAWINGS.

SHEET KEYNOTES#

D N

RESTR'M/1-2

OFFICE/1-2

CORR.

LAUNDRY

JAN.

OFFICE/1-2

RESTR'M/1-2

RESTR'M/1-2

RESTR'M/1-2

RESTR'M/1-2

BEDR'M/1-2STAFF RMSUPPLY RM

ACC-1

(E) RS

(E) RL

(E) ACC-11

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

MD101

MECHANICAL - DEMO PLAN

LEVEL 1

X-1496

1/4" = 1'-0"

MECHANICAL - DEMO- LEVEL 1 - DEMO

1. REMOVE EXISTING AIR-COOLED CHILLER, ALL

REFRIGERANT PIPING, INSULATION, HANGERS,

VALVES, AND RELATED ACCESSORIES.

SHEET KEYNOTES#

2'0' 1' 4'2'0' 1' 4'

BASEMENT

01B

(E) 4" CHWR

(E) AHU

(E) 4" CHWS

(E) 2" CHWR

(E) 2" CHWS

(E) 2" CHWS

(E) 2" CHWR

(E) 4" CHWS

(E) 4" CHWR

(E) 2-1/2" CHWS

(E) 4" CHWS

(E) 4" CHWS

(E)3/4" CWS FILL FROM EXISTING

BACKFLOW PREVENTER

(E) EXPANSION TANK

(E) CHEMICAL FEED POT

RSL

RLL

AS

P

(E) 3/4" CHWR

3 1

HX

(E)4" CHWR

4" CHWR

4" CHWS

(E) 2" CHWR

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

M100

MECHANICAL - NEW WORK

PLAN BASEMENT

X-1496

1/4" = 1'-0"

MECHANICAL - NEW WORK - BASEMENT PLAN

SHEET KEYNOTES#

1. INSTALL NEW CHILLED WATER PUMP P-1 ON

EXISTING PAD. MAKE ALTERATIONS TO PAD TO

FIT EQUIPMENT FURNISHED CONNECT EXISTING

CHILLED WATER PIPING AND ADJUST ROUTING

TO FIT EQUIPMENT FURNISHED. FOR

INSTALLATION, REFER TO DETAIL 4/M500.

2. INSTALL NEW AIR SEPARATOR TO EXISTING

PIPING. MAKE ANY ADJUSTMENTS TO FIT

EQUIPMENT FURNISHED. CONNECT EXISTING

CHILLED WATER PIPING AND ADJUST ROUTING

TO FIT EQUIPMENT FURNISHED. FOR

INSTALLATION, REFER TO DETAIL 3/M500.

3. INSTALL NEW HEAT EXCHANGER ON EXISTING

PAD. MAKE ALTERATIONS TO PAD AS NEEDED

TO FIT EQUIPMENT FURNISHED. CONNECT

EXISTING CHILLED WATER PIPING AND NEW

REFRIGERANT PIPING AND ADJUST ROUTING TO

FIT EQUIPMENT FURNISHED. SEE DETAIL 1/M500

FOR PIPING ACCESSORIES REQUIRED.

4. INSTALL NEW REFRIGERANT PIPE BETWEEN

NEW CHILLER CONDENSER AND PLATE AND

FRAME HEAT EXCHANGER EVAPORATOR.

ROUTE REFRIGERANT PIPING THRU EXISTING

SLEEVES IN WALL AND PER INSTALL DETAIL

2/M500. INCLUDE ALL ACCESSORIES SHOWN IN

DETAIL 1/M500.

5. REFRIGERANT PIPE SIZES NOT SHOWN. PIPING

SHALL BE SIZED BY THE CONTRACTOR BASED

ON FINAL SHOP DRAWING LAYOUT AND SHALL

BE COORDINATED WITH MANUFACTURER

AND/OR THE INSTALLATION AND OPERATION

MANUALS.

2'0' 1' 4'2'0' 1' 4'

DN

N

DN

D N

WDWD

BEDR'M/1-2

C0RR.

RESTR'M/1-2

C0RR.

CLOSET

KITCHEN/1-2

12A

OFFICE/1-2

REC RM/1-2

STORAGEMEDS/1-2

CORR.

SOILED

LINEN

LAUNDRY

AIDE'S RR

JAN.

AIDE'S STATION CORR.

LIV RM/1-2

STAIRWAY

CLOSET

CLOSET

ACTIVITIES/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

DW

OFFICE/1-2

RESTR'M/1-2

RESTR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

RESTR'M/1-2

RESTR'M/1-2

RESTR'M/1-2

BEDR'M/1-2

BEDR'M/1-2STAFF RMSUPPLY RM

59 / 11.8"

35"

59 / 11.8"

35"

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

BEDR'M/1-2

DN

ACC-1

RSL

RLL

NEW ACC-11

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

M101

MECHANICAL - NEW WORK

PLAN LEVEL 1

X-1496

8'0' 4' 16'

1/8" = 1'-0"

MECHANICAL - NEW WORK - LEVEL 1

1. INSTALL NEW AIR-COOLED CHILLER ON

EXISTING CONCRETE PAD. INSTALL NEW

REFRIGERANT PIPING, INSULATION, HANGERS,

VALVES, AND RELATED ACCESSORIES. ROUTE

NEW REFRIGERANT PIPING THROUGH EXISTING

SLEEVES IN WALL.

SHEET KEYNOTES#

SHUT OFF VALVE,

(TYP), SEE SPEC FOR

TYPE

CALIBRATED BALANCE

VALVE (TYP)

3/4" DRAIN VALVE, NIPPLE,

AND CAP (TYP)

CONCENTRIC REDUCER (IF

REQUIRED)

ECCENTRIC INCREASER (IF

REQUIRED)

CONCENTRIC REDUCER

(IF REQUIRED)

STRAINER WITH

BLOWDOWN VALVE,

NIPPLE, AND CAP

SOURCE

M

M 2-WAY MODULATING

CONTROL VALVE

SYSTEM

PRESSURE AND TEMPERATURE TEST

PLUGS (TYP). INSTALL AT SAME

ELEVATION.

RELIEF VALVE PIPED TO FLOOR

DRAIN (2 TYP)

NOTE:

PIPING ARRANGEMENT IN AND OUT OF HEAT EXCHANGER MAY VARY

BETWEEN MANUFACTURERS. CONTRACTOR SHALL MAKE ALL PIPING

CONNECTIONS IN ACCORDANCE TO SPECIFIC MANUFACTURER'S GUIDELINES.

HX

MANUAL AIR

VENT (TYP)

UNION OR FLANGE (TYP)

CHWS

CHWR

RLL

RSL

OAKUM PACKING

BITUMASTIC SEAL

HOT PITCH SEAL FOR

EXTERIOR BELOW GRADE

HYDRO-STATIC CLOSURE

("LINK-SEAL")

CORE DRILL OPENING

STEEL PIPE

REFER TO

SPECIFICATIONS FOR

PIPE REQUIREMENTS

OUTSIDE WALL

LONG

RADIUS

ELBOW

ADJUSTABLE PIPE

SUPPORT LEG

LEVEL PUMP AND FILL

WITH NON-SHRINK

GROUT

3/4" DRAIN VALVE W/

HOSE CONNECTION

GROUTABLE

FABRICATED

STEEL BASE PLATE

NOTES:

1. PUMP MOUNTED PER MANUFACTURER'S RECOMMENDATION.

2. LONG-RADIUS PIPE ELBOWS REQUIRED PER SPECIFICATIONS.

3. SUCTION DIFFUSER MAY BE USED IN LIEU OF STRAINER, STRAIGHT

PIPE, BEND AND REDUCER. ONLY WHEN SPACE DOES NOT PERMIT

STRAIGHT PIPE LENGTH AT INLET

4. REFER TO SPECIFICATION SECTION 230548 FOR DETAILS.

5. GROUT BASE AFTER PIPE INSTALLATION AND SYSTEM IS FILLED.

6. INERTIA BASE SHALL BE SIZED TO SUPPORT PUMP AND SUCTION

ELBOW.

7. REFER TO SINGLE LINE DIAGRAMS FOR PIPE SIZES.

8. PROVIDE MINIMUM FIVE (5) DIAMETERS OF STRAIGHT PIPE.

9. IF STRAIGHT PIPE IS GREATER THAN TWENTY (20) PIPE DIAMETERS OF

SUCTION PIPE, ROUTE FROM BELOW FLAT SIDE OF REDUCER TO BE ON

TOP SIDE OF PIPE.

10. PUMP IS CONSTANT FLOW. ADJUST CHILLED WATER SUPPLY

TEMPERATURE WITH A MIXING BYPASS ADDING CHILLED WATER

RETURN FLOW TO THE CHILLED WATER SUPPLY FLOW, LOWERING THE

CHILLED WATER SUPPLY TEMPERATURE DURING PART LOAD USAGE.

FLOW THROUGH HEAT EXCHANGER AND THE PUMP SHALL REMAIN

CONSTANT.

P

COUPLING GUARD

PUMP

MOTOR

CONCENTRIC

REDUCER

(WHERE REQUIRED)

NEOPRENE FLEX

CONNECTOR W/

CONTROL CABLE

CHECK VALVE

BALANCING VALVE

SHUT-OFF VALVE

PRESSURE

GAUGE

1/2"ø

NEEDLE

VALVE

(TYP.)

STRAINER W/

BLOWDOWN

SHUT-OFF

VALVE

PIPE HANGER W/

VIBRATION ISOLATION

5" CONCRETE

PAD

FINISHED

FLOOR

3 10 11

INERTIA BASE SEE

SPECIFICATION FOR

REQUIREMENTS

NEOPRENE PAD

(TYP.)

A

3/4" HOSE-END VALVE W/CAP

TO DRAIN

CHILLED WATER RETURN LINE

SHUTOFF VALVE (TYP),

SEE SPEC FOR TYPE

(E) AIR VENT

(E) PIPING

TO PUMP

SUCTION,

(TYP)

FLR

AS

UNION (TYP)

A

CW

(E) SAFETY

RELIEF

VALVE

(E) HIGH CAPACITY

AUTOMATIC AIR VENT

SET TO 10PSI ABOVE

SYSTEM PRESSURE

(E) EXPANSION TANK

DOWNSTREAM PIPE AND ACCESSORIES EXISTING TO REAMAIN

UPSTREAM PIPE AND ACCESSORIES EXISTING TO REMAIN

AIR-COOLED CHILLER

CONDENSING UNIT

CHILLER EVAPORATOR

HEAT EXCHANGER

RLL

RSL

FROM PUMP

TO BUILDING

KEYNOTES

1. REFRIGERANT PIPE SIZED PER

MANUFACTURER'S RECOMMENDATION.

4" CHWR

4" CHWS

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

M500

MECHANICAL - DETAILS &

CONTROL

X-1496

NTS

PLATE AND FRAME HEAT EXCHANGER PIPING DIAGRAM 2-WAY VALVE

12" = 1'-0"

PIPE THROUGH EXTERIOR WALL

NTS

END SUCTION BASE MOUNTED PUMP ON ISOLATORS DETAIL

NTS

AIR SEPARATOR AND EXPANSION TANK (FLOOR MOUNTED) PIPING DETAIL

CHILLED WATER SYSTEM SEQUENCE OF OPERATION

THE CHILLED WATER SYSTEM HAS AN EXISTING CONTROL SEQUENCE. FOR MORE INFORMATION ABOUT THE EXISTING CONTROL SYSTEM, THE CONTRACTOR SHALL CONTACT THE PSH HVAC SUPERVISOR NATHAN FORKNER AT 620-448-3236 (OFFICE) OR 620-423-9784 (MOBILE PHONE). THE CHILLED WATER SYSTEM IS CONNECTED TO A BUILDING MANAGEMENT SYSTEM (BMS). FOR MORE INFORMATION ON THE BMS SYSTEM CONTACT C&C GROUP, 2534 N PATTERSON AVE, SUITE 100, SPRINGFIELD, MO. 65803. THE CONTACT IS ROBERT LUTGEN AT 417-368-1660.

PROVIDE THE FOLLOWING DATA AND CONTROL POINTS AND COMMUNICATE THESE TO BMS:

• SUPPLY CHILLED WATER TEMPERATURE SETPOINT *

• SUPPLY CHILLED WATER TEMPERATURE *

• RETURN CHILLED WATER TEMPERATURE *

• OUTSIDE AIR TEMPERATURE *

• OUTSIDE AIR TEMPERATURE ENABLE COMMAND SETPOINT *

• CHILLER COMMAND *

• CHILLER STATUS WITH NUMBER OR % OF COMPRESSORS RUNNING *

• PUMP COMMAND

• PUMP STATUS

* FROM CHILLER CONTROLS PROVIDED WITH EQUIPMENT FURNISHED.

NTS

CHILLER PIPING DIAGRAM

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all other plans, specifications, estimates, reports, documents or instruments not sealed by the Professional DOR relating to, or intended to be used for, any part or parts of the project to which this document refers. Prints sealed by the DOR bear the embossed or wet seal of the DOR across the signature and date. Copies of this document, as signed and sealed, have been retained by the

Professional DOR. The Professional DOR will not be responsible for subsequent changes to this document, unless the changes are made by the DOR or with the

DOR's written authorization.

1 INCH

ARCHITECTURE &

ENGINEERING

1 62 3 4 5

E

D

C

B

A

D E

P A

R T

M E

N T

M

IN

IS

T R

A T

IO

N

O F

F

IC

E

C

IL

IT

IE

S

P R

O C

U R

E M

E

N A

G E

M E

N T

D E

S

IG

N

C O

N S

T R

U C

T

IO

M

P L

IA

N

C E

R R

IS

O

N

S U

IT

E

P E

K A

K

A N

S A

S

O N

E

-2

-8

LISA D. AKAGI

PE - 22870

G

A B

R

IE

L A

V E

P

A R

S O

N S

K

S

B U

IL

D

IN

G

N U

M B

E R

-0

P A

R S

O N

S S

T A

T E

H O

S P

IT

A

L

T R

A

IN

IN

G

C E

N T

E R

A

IR

C O

O L E

D C

H

IL

L E

R R

E P

L A

C E

M E

N T

IS

S

U E

D A

T E

/1

/2

D E

S

IG

N E

D B

Y

L D

A

100% CONSTRUCTION

DOCUMENT

S T

A T

E O

F K

A N

S A

S

M600

MECHANICAL - SCHEDULES

X-1496

ACC 1 YORK YLAA0101 AIR COOLED SCROLL AT GRADE OUTSIDE HICKORY CHILLED WATER R454B 100 100 97.77 54 44 233 9.5 5 2 17 10 95 12' X 8' X 8' 5000 467 113 208 3 1, 2

ID # CAPACITY (MBH) EWT (°F) LWT (°F) FLOW (GPM) MAX WPD (FT) AMPS KW VOLTS PHASE

MARK

MFR MODEL TYPE LOCATION SERVICE

REFR

TYPE

DESIGN AMBIENT

TEMP (°F) NOM TONS

EVAPORATOR

MIN # OF COMPRESSORS MIN # OF CIRCUITS MIN IPLV (EER)

MAX FULL LOAD

EFF (EER)

MAX SOUND

PRESS

MAX SIZE LxWxH

(FT)

MAX OPERATING

WEIGHT (LBS)

ELECTRICAL DATA

NOTES

2 CHILLER EVAPORATOR SHALL BE A BRAZED PLATE AND FRAME HEAT EXCHANGER LOCATED REMOTELY IN THE MECHANICAL ROOM. SEE SCHEDULE BELOW.

1 CHILLER SHALL BE DELIVERED WITH A SINGLE POINT POWER CONNECTION AND DISCONNECT IN THE CHILLER CONTROL PANEL.

NOTES:

AIR COOLED CHILLER SCHEDULE

AS 1

BELL &

GOSSETT R-4F CENTRIFUGAL

HICKORY

BASEMENT

MECHANICAL

ROOM

CHILLED

WATER 246 2 1

ID #

MARK

MFR. MODEL TYPE LOCATION SERVICE FLOW (GPM) MAX WATER PD (FT) NOTES

2. SUPPLY A SEPARATOR THAT HAS A MINIIMUM % OF AIR ELEMINATION IF 70% AT A % OF MAXIMUM FLOW OF 0.82.

1. PROVIDE WITH HIGH CAPACITY AUTOMATIC AIR VENT.

NOTES:

AIR SEPARATOR SCHEDULE

P 1

BELL &

GOSSETT 1510

BASE MOUNTED

END SUCTION

HICKORY BASEMENT

MECHANICAL ROOM

CHILLED

WATER 246 60 3 / 2.5 6.45 70 1800 7.5 208 3 1,2

ID # HP VOLTS PHASE

MARK

MFR. MODEL TYPE LOCATION SERVICE

WATER

FLOW

(GPM)

TDH

(FT)

MIN INLET /

OUTLET

SIZES (IN)

MIN NPSH

REQD (FT)

MIN EFF

MOTOR

SPEED

(RPM)

ELECTRICAL DATA

NOTES

2. UTILIZE EXISTING STARTER/DISCONNECT WITH THE ENW PUMP.

1. REFER TO DETAIL 4/M500 FOR INSTALLATION REQUIREMENTS, INCLUDING VIBRATION ISOLATION.

NOTES:

PUMP SCHEDULE

(1) HEAT EXCHANGER TO BE PROVIDED BY THE AIR COOLED CHILLER MANUFACTURER, WITH THE AIR COOLED CHILLER.

(2) INCLUDE FLOOR MOUNT BRACKET.

(3) CONTRACTOR TO PROVIDE 4" HIGH HOUSEKEEPING PAD.

(4) TO MATCH THE PROVIDED AIR-COOLED CHILLER.

NOTES:

* CELLS WITH SHADED BACKGROUNDS ARE UNASSIGNED OR UNDER REVIEW

MECHANICAL - HEAT EXCHANGER (PLATE AND FRAME) SCHEDULE

TYPE EQUIPMENT NUMBER MANUFACTURER MODEL

LOCATION

SERVICE

REFRIGERANT SIDE BUILDING LOAD SIDE PLATES DIMENSIONS

OPERATING WEIGHT (LB) NOTES

CAPACITY (BTUH) ET (°F) LT (°F) GPM WPD (FT WC) MEDIUM CAPACITY EWT (°F) LWT (°F) FLOW (GPM) WPD (FT WC) MEDIUM MATERIAL NO. OF PLATES MAX NO. OF PLATES L W H

HX 1 ALFA-LAVA ACH-502DQ-142AH-F HICKORY BASEMENT MECHANICAL ROOM CHILLED WATER NOTE 4 NOTE 4 NOTE 4 NOTE 4 NOTE 4 R454R 97 54.0 44.0 233.0 10.0 WATER SS 145 270 15" 13" 30" 200 1,2,3

M

K

AM

IQ

ELECTRICAL SYMBOLS AND LEGEND

RECEPTACLES / POWERWALL CEILING

NOTE: ALL RECEPTACLE OUTLETS ON WALLS ARE MOUNTED AT 18" AFF, UON.

LETTER RATING

A B D F G H J K L

M N P R S T

X Z

125V, 1Ø, 30A, 2P, 3W 125V, 1Ø, 50A, 2P, 3W 125/250V, 1Ø, 20A, 3P, 4W 125/250V, 1Ø, 30A, 3P, 4W 125/250V, 3Ø, 20A, 3P, 4W 125/250V, 3Ø, 30A, 3P, 4W 250V, 1Ø, 20A, 2P, 3W 250V, 1Ø, 30A, 2P, 3W

250V, 1Ø, 50A, 2P, 3W 250V, 3Ø, 20A, 3P, 4W 250V, 3Ø, 30A, 3P, 4W 250V, 3Ø, 50A, 3P, 4W 480V, 3Ø, 30A, 3P, 4W 125V, 1Ø, 20A, 2P, 3W

125V, 1Ø, 20A, 2P, 3W 480V, 3Ø, 20A, 3P, 4W

NEMA

5-30R 5-50R 14-20R 14-30R

L21-20R L21-30R 6-20R 6-30R

6-50R 15-20R 15-30R 15-50R

L16-30R 5-20R

5-20R L16-20R

WITH 5-30P PLUG

WITH 5-50P PLUG

WITH 14-20P PLUG

WITH 14-30P PLUG

WITH L21-20P PLUG

WITH L21-30P PLUG

WITH 6-20P PLUG

WITH 6-30P PLUG

'L' INDICATES ASSOCIATED RECEPTACLE IS

LOCKING TYPE, PROVIDE MATCHING PLUG

FOR EACH RECEPTACLE

WITH 6-50P PLUG

WITH 15-20P PLUG

WITH 15-30P PLUG

WITH 15-50P PLUG

WITH L12-30P PLUG

ISOLATED GROUND WITH INTEGRAL

TRANSIENT SUPPRESSOR AND DEDICATED

GREEN/YELLOW CONDUCTOR BACK TO

GROUND BUS AT PANEL

DEDICATED CIRCUIT

WITH L16-20R PLUG

SPECIAL RECEPTACLE DESCRIPTION SCHEDULE

NOTE: NUMBER OF WIRES INCLUDE GROUND

EXISTING / DEMOLITION

EXISTING EQUIPMENT / RACEWAYS TO REMAIN

EXISTING EQUIPMENT / RACEWAYS TO BE REMOVED

NEW EQUIPMENT / RACEWAYS

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW EQUIPMENT, LIGHTING FIXTURE OR DEVICE

SINGLE LINE DIAGRAM

X X

E-6

P

A

E-6

GENERAL ELECTRICAL SYMBOLSRECESSED SURFACE

DISCONNECT SWITCH, 30 AMP MINIMUM UNLESS NOTED

OTHERWISE

FREE STANDING SWITCHBOARD, MOTOR CONTROL

CENTER OR DISTRIBUTION BOARD

A-1,3,5

RACEWAYS AND WIRINGFLOOR WALL CEILING

CONDUIT CONCEALED IN CEILING OR WALL SPACE

J

J

J

J

SIMPLEX RECEPTACLES

JUNCTION BOX 4" SQUARE MINIMUM FOR WALL

OR CEILING MOUNTED

DUPLEX RECEPTACLES

SPECIAL RECEPTACLES (DUPLEX &

QUADRUPLEX), REFER TO SPECIAL

RECEPTACLE SCHEDULE, THIS SHEET

GROUND FAULT CIRCUIT INTERRUPTING

RECEPTACLES

JUNCTION BOX SIZE AS REQUIRED FOR

NUMBER OF WIRES OR RACEWAYS

EEE

X33

+4'-6"

MH=4'-6"

A-1 A-1A-1

FIRE TREATED PLYWOOD BACKBOARD 3/4"X96" HIGH X

LENGTH AS INDICATED

ELECTRICAL EQUIPMENT DESIGNATION DESIGNED

"EQ01"

REFERENCE TO NOTE "1" ON SAME SHEET

MECHANICAL EQUIPMENT DESIGNATION "P-1"

INDICATED

EQUIPMENT NAME OR NUMBER

MOUNTING HEIGHT FROM FINISHED FLOOR TO

CENTERLINE OF OUTLET OR EQUIPMENT

MOUNTING HEIGHT FROM FINISHED FLOOR TO BOTTOM

OF OUTLET OR EQUIPMENT

DETAIL REFERENCE NUMBER "1" ON DRAWING "E-6"

SECTION OR ELEVATION REFERENCE LETTER "A" ON

DRAWING "E-6"

INDICATES HOMERUN WITH THREE CIRCUITS AND A

SEPARATE NEUTRALS

CONDUIT RUN EXPOSED

CONDUIT RUN UNDERGROUND OR CONCEALED IN

FLOOR SPACE

EXISTING CONDUIT TO REMAIN

CONDUIT RISING UP FROM RUN

CONDUIT DROPPING DOWN FROM RUN

HOMERUN TO PANELBOARD, CABINET OR TERMINAL

BACKBOARD AS INDICATED

FUSED DISCONNECT SWITCH, 30 AMP MINIMUM UNLESS

NOTED OTHERWISE

COMBINATION DISCONNECT SWITCH MOTOR STARTED

MOTOR, 5 HP INDICATED

TRANSFORMER

RELAY OR EQUIPMENT CABINET AS INDICATED ON

PLAN

LIGHTING OR POWER PANEL BOARD

T

GROUNDING SYSTEMFLOOR WALL

GROUND PLATE, FLAT TAPPED SIDE TO BE FLUSH WITH

FURNISHED SURFACE. CADWELD B164-2Q OR

EQUIVALENT

G

TG

G

TG

GROUND BUS

TECHNICAL GROUND BUS

G

EXOTHERMIC GROUND CONNECTION

GROUND WIRE

GROUND ROD

GROUND ROD TEST WELL

S

G

CIRCUIT BREAKER, 3 POLE UNLESS NOTED OTHERWISE

MOTOR STARTER WITH OVERCURRENT PROTECTION, 3

POLE UNLESS NOTED OTHERWISE

MOTOR STARTER WITH FUSED AND DISCONNECT SWITCH,

3 POLE UNLESS NOTED OTHERWISE

GROUND FAULT RELAY

SHUNT TRIP RELAY

DRAW-OUT CIRCUIT BREAKER

NON-FUSED DISCONNECT SWITCH, 30 AMP, 3P UNLESS

NOTED OTHERWISE

FUSED DISCONNECT SWITCH, 3 POLE UNLESS NOTED

OTHERWISE

DEMAND TYPE KWH METER

DEMAND TYPE KWH METER WITH ENCLOSURE

PROVISION FOR UTILITY COMPANY KWH METER

KIRK-KEY INTERLOCK BETWEEN DEVICES

AUTOMATIC TRANSFER SWITCH WITH GENERATOR

STARTING AND TRANSFER SWITCH STATUS CONTACTS

CURRENT TRANSFORMER (CT)

AMMETER

ELECTRONIC METER

SEPARABLE CONNECTOR(S)

EMERGENCY GENERATOR, AS NOTED ON SINGLE LINE

DIAGRAM

GROUND

AUTOMATIC TRANSFER SWITCH WITH BY-PASS

ISOLATION, GENERATOR STARTING CONTACTS AND

TRANSFER SWITCH STATUS CONTACT

TRANSFORMER , AS NOTED ON SINGLE LINE DIAGRAM

ISOLATION TRANSFORMER , AS NOTED ON SINGLE LINE

DIAGRAM

CIRCUIT BREAKER BUS TAP

VFD VARIABLE FREQUENCY DRIVE

SURGE PROTECTIVE DEVICE

PNL

PNL

PNL

PNL PNL

PNL

PANELBOARD WITH LUGS ONLY. UP TO 84 CIRCUITS

IN A SINGLE CABINET. REFER TO PANEL SCHEDULE

FOR ADDITIONAL INFORMATION

PANELBOARD WITH MAIN CIRCUIT BREAKER. UP TO 84

CIRCUITS IN A SINGLE CABINET. REFER TO PANEL

SCHEDULE FOR ADDITIONAL INFORMATION.

PANELBOARD WITH MAIN CIRCUIT BREAKER AND

FEED THROUGH GUTTER AND FEEDER TAP IN

GUTTER. UP TO 84 CIRCUITS IN A SINGLE CABINET.

REFER TO PANEL SCHEDULE FOR ADDITIONAL

INFORMATION.

PANELBOARD WITH MAIN CIRCUIT BREAKER AND

FEED THROUGH GUTTER AND FEEDER TAP IN

GUTTER. UP TO 84 CIRCUITS IN EACH CABINET. REFER

TO PANEL SCHEDULE FOR ADDITIONAL INFORMATION.

A. GENERAL REQUIREMENTS

1. DEFINITIONS FOR TERMS USED IN THE ELECTRICAL DOCUMENTS:

a. DRAWINGS = LATEST VERSION OF THE PROJECT DRAWINGS UNLESS NOTED OTHERWISE

b. SPECIFICATIONS = LATEST VERSION OF THE OF THE PROJECT MANUAL OR SPECIFICATIONS

UNLESS NOTED OTHERWISE

c. CONTRACT DOCUMENTS = LATEST VERSION OF THE PROJECT DRAWINGS AND PROJECT

SPECIFICATIONS

d. CONTRACTOR = ANY OR ALL OF THE FOLLOWING, CONSTRUCTION MANAGER, GENERAL

CONTRACTOR AND ALL OF THEIR SUB-CONTRACTORS, FABRICATORS AND SUPPLIERS

2. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE ELECTRICAL SYSTEMS WITH THE

WORK OF ALL OTHER TRADES, ARCHITECT AND THEIR CONSULTANTS, CIVIL, STRUCTURAL AND

OWNER AS WELL AS ANY FABRICATOR OR SUPPLIER FOR APPLICABLE TRADES.

3. SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT DOCUMENTS AND SHALL BE USED IN

CONJUNCTION WITH ELECTRICAL DRAWINGS.

4. THE CONTRACTOR IS RESPONSIBLE FOR MANNING THE PROJECT TO MEET THE PROJECT

SCHEDULE AND FOR MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION. THE DESIGN TEAM

ASSUMES NO RESPONSIBILITY.

B. GENERAL PROVISIONS:

1. SUBMISSION OF A BID BY THE CONTRACTOR IS NOTIFICATION THAT THE CONTRACTOR HAS

RECEIVED A COMPLETE SET OF CONSTRUCTION DOCUMENTS, SPECIFICATIONS, ANY AND ALL

ADDENDUMS FROM ALL TRADES AND HAS REVIEWED ALL DOCUMENTS. ALL WORK NOT

NECESSARILY RESTRICTED TO THESE DOCUMENTS BUT REQUIRED TO PROVIDE A COMPLETE AND

FUNCTIONING ELECTRICAL SYSTEM HAS BEEN INCLUDED IN THE BID.

2. THESE CONSTRUCTION DOCUMENTS DO NOT DEFINE SCOPE OF CONTRACTS. ELECTRICAL

SYSTEMS AND CONTROLS SHALL BE COMPLETE AND FUNCTIONAL. REFER TO CONSTRUCTION

MANAGER, GENERAL CONTRACTOR, OR OWNER FOR DEFINITION OF SCOPES WITHIN THESE

DOCUMENTS.

3. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT A COMPLETE AND WORKABLE

ELECTRICAL INSTALLATION BE PROVIDED FOR ALL THE EQUIPMENT DESCRIBED OR SHOWN AS

BEING IN THIS CONTRACT. TOWARD THIS END, CONTRACTOR SHALL FURNISH ALL LABOR AND

TOOLS NECESSARY, FURNISH AND INSTALL ALL APPARATUS, MATERIALS, AND EQUIPMENT IN A

MANNER COMPLYING WITH ALL APPLICABLE CODES, INCLUDING ITEMS REQUIRED BUT NOT

NECESSARILY SHOWN, SUCH AS LAMPS, COUPLINGS, HANGERS, BRACKETS, CLAMPS, BOXES,

CONNECTORS, AND HARDWARE.

4. THESE DOCUMENTS ARE PART OF A COMPLETE SET OF CONSTRUCTION DOCUMENTS. THE

CONSTRUCTION DOCUMENTS DO NOT SHOW EVERY ITEM OR COMPONENT REQUIRED TO PROVIDE

A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. CONTRACTOR SHALL MAKE USE OF ALL

CONSTRUCTION DOCUMENTS TO DETERMINE FULL SCOPE AND FURNISH AND INSTALL ALL

SPECIFIED AND APPROPRIATE INCIDENTAL AND ACCESSORY ITEMS NOT INDICATED BUT REQUIRED

TO PROVIDE FOR A COMPLETE AND FINISHED ELECTRICAL SYSTEM.

5. CATALOG NUMBERS WHEN INDICATED ON DRAWINGS ARE TO ESTABLISH A MANUFACTURER AND

SHALL BE USED IN CONJUNCTION WITH SPECIFICATIONS. WHERE CATALOGUE NUMBER AND

SPECIFICATIONS ARE IN CONFLICT THE MOST STRINGENT INTERPRETATION SHALL BE USED.

6. ALL CONDUCTORS SHALL BE COPPER, TYPE "THWN/THHN" WITH 90 DEGREE INSULATION. ALL LUGS SHALL BE 75 DEGREE MINIMUM. ALL CONDUIT SHALL BE EMT OR ERMC AS PER SPECIFICATIONS.

USE OF FLEX IS NOT ALLOWED EXCEPT UP TO 6 FOOT FOR FINAL CONNECTION TO LIGHTING

FIXTURES OR VIBRATING EQUIPMENT.

7. BEFORE SUBMITTING THE BID PROPOSAL, CONTRACTOR SHALL VISIT THE JOB SITE TO FULLY FAMILIARIZE HIMSELF WITH THE SITE CONDITIONS, REQUIREMENTS, INCLUDING ALL NECESSARY

ADDITIONAL SCOPE OF WORK, WHETHER SHOWN ON DRAWING(S) OR NOT, BUT REQUIRED FOR

PROVIDING A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM.

8. CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS AND WIRING DIAGRAMS FOR ITEMS AND

DEVICES TO BE FURNISHED, INSTALLED AND/OR CONNECTED FOR A COMPLETE AND OPERABLE

HEATING, VENTILATION AND AIR CONDITIONING (HVAC) SYSTEM. VERIFY EXACT LOCATION OF HVAC

EQUIPMENT AND CONDUIT TERMINATION AT EQUIPMENT WITH MECHANICAL CONTRACTOR.

9. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE LOCATION OF

OUTLETS AND EQUIPMENT THOUGH NOT NECESSARILY INDICATING THE ACTUAL ROUTES OF

CONDUITS, THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH

THE WORK OF OTHER TRADES AND SPACE WILL PERMIT. IT IS NOT WITHIN THE SCOPE OF THE

DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, PULL BOXES AND OBSTRUCTIONS. THE

DRAWINGS ARE NOT INTENDED TO BE SCALED.

10. ELECTRICAL RACEWAYS SHALL BE INSTALLED AS HIGH AS POSSIBLE AND TIGHT AGAINST THE DECK ABOVE IS PREFERRED. ACCESS TO PULL BOXES AND JUNCTION BOXES SHALL BE MAINTAINED AND OFFSETS TO RACEWAY INSTALLATION MAY BE INSTALLED AS REQUIRED TO MAINTAIN ACCESS AND

TRANSITION BACK TO THE DECK ABOVE AFTER PASSING THROUGH.

11. ALL EXTERIOR CONDUITS ROUTED IN GRADE SHALL BE TERMINATED WITH MECHANICAL SEALS TO

PREVENT MOISTURE FROM ENTERING BUILDING OR PAD MOUNTED ENCLOSURES. BOTH CONDUIT

ENDS SHALL BE SEALED. CONDUITS FROM BELOW GRADE SHALL BE SEALED UTILIZING FITTING SIMILAR TO OR EQUAL TO OZ/GEDNEY TYPE 'FSK' THRU-WALL FITTING WITH 'FSKA' MEMBRANE

ADAPTER CLAMP. REFER TO SPECIFICATIONS FOR PENETRATION SEALS AND REQUIREMENTS.

12. INSTALL NO MORE THAN EQUIVALENT OF THREE 90-DEGREE BENDS IN CONDUIT RUN EXCEPT FOR CONTROL WIRING CONDUITS, FOR WHICH NO MORE THAN EQUIVALENT OF TWO 90-DEGREE FEWER

BENDS ARE PERMITTED.

13. ALL PERMITS SHALL BE PROCURED FROM ALL LEGALLY CONSTITUTED AUTHORITIES, ARRANGE FOR ALL INSPECTION AND PAY ALL COSTS FOR FEES AND TESTS IN CONNECTION THEREWITH, COMPLY

WITH CODES. PRESENT THE SIGNED CERTIFICATE OF FINAL INSPECTION TO THE OWNER'S

REPRESENTATIVE PRIOR TO PRESENTING THE WORK FOR FINAL ACCEPTANCE.

14. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FOR SUBMITTALS, ACCEPTABLE

MATERIALS, COORDINATION REQUIREMENTS, TESTING, STARTUP, TRAINING AND PROJECT

CLOSEOUT.

15. PROVIDE A CODE APPROVED DISCONNECT SWITCH OR BREAKER WITHIN SIGHT OF EVERY MOTOR.

FOR LOCATION OF DISCONNECT SWITCH, COORDINATE WITH EQUIPMENT SUPPLIER TO DETERMINE THE BEST LOCATION ON SITE WHILE REMAINING ACCESSIBLE. THE DISCONNECT MEANS MAY BE

INSTALLED ON THE EQUIPMENT, BUT SHALL NOT BE LOCATED ON ACCESS PANELS OR COVER

MANUFACTURERS LABELING.

16. CONTRACTOR SHALL TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY, GROUNDS, SHORT

CIRCUITS, AND OTHER DEFECTS BEFORE ANY EQUIPMENT OR FIXTURES ARE CONNECTED

THERETO. CABLES SHALL BE CHECKED FOR CONTINUITY, SHORTS, INSULATION RESISTANCE, AND

PROPER PHASING.

17. PROVIDE PULL ROPE IN ALL EMPTY RACEWAYS. RACEWAYS SHALL BE TAGGED WITH LOCATION OF

OPPOSITE END OF RACEWAY AND INCLUDE PROPOSED FUTURE USE OF RACEWAY.

18. ROUTING OF RACEWAYS FEEDERS AND HOMERUNS ARE NOT INDICATED ON THESE DOCUMENTS

AND MUST BE DETERMINED BY CONTRACTOR IN COOPERATION WITH THE WORK OF OTHER

TRADES.

19. NO MORE THAN THREE CIRCUITS PER HOME RUN. DO NOT COMBINE HOMERUNS WITHOUT PRIOR

APPROVAL.

20. NO INTERMEDIATE SPLICING OF FEEDERS OR BRANCH CIRCUITS SHALL BE DONE WITHOUT PRIOR

APPROVAL.

21. ALL SINGLE PHASE, SINGLE POLE LOADS TO HAVE DEDICATED NEUTRALS. LABEL NEUTRAL

CONDUCTORS WITH CORRESPONDING CIRCUIT NUMBER AT EACH PULL BOX, JUNCTION BOX,

HANDHOLE, AND OTHER SPLICE POINT. USE OF BREAKER TIES IS NOT PERMITTED. SHARING OF

NEUTRALS IS NOT PERMITTED.

22. MINIMUM SIZE FOR INTERIOR BRANCH CONDUIT SHALL BE ¾” CONDUIT

23. WHERE CIRCUIT NUMBERS ARE SHOWN, WITHOUT CONDUIT AND WIRE INDICATIONS, CONDUCTOR

SIZE SHALL EQUAL BRANCH OVERCURRENT PROTECTION SIZE. REFER TO CONDUIT AND

CONDUCTOR LEGEND FOR MINIMUM RACEWAY SIZES

24. PROVIDE FIREPROOFING FOR ALL FLOOR PENETRATIONS AND FOR ALL WALL PENETRATIONS

THROUGH MULTIPLE CONDUITS PENETRATING FIRE RATED WALLS OR FLOOR SLABS SHALL BE

SEPARATED BY 2" AND THE OPENING AROUND THE CONDUIT SEALED WITH UL LISTED FIRE RATED CAULK AS REQUIRED BY UL LISTED ASSEMBLY. FIREPROOFING SYSTEM SHALL MEET OR EXCEED

THE RATING OF THE PENETRATED STRUCTURE.

25. DEVICES OR BOXES INSTALLED IN FIRE RATED PARTITIONS OR SLABS SHALL BE INSTALLED IN

COMPLIANCE WITH UL LISTED ASSEMBLY THAT MEETS OR EXCEEDS THE FIRE RATING OF THE

PARTITION OR SLAB.

26. WHERE UNDERGROUND RACEWAYS TURN UP INTO CABINETS, EQUIPMENT, ETC. OR ON TO POLES, THE ELBOW REQUIRED AND THE STUB-OUT OF THE SLAB OR EARTH SHALL BE GALVANIZED RIGID

STEEL.

C. SITE WORK:

1. EXISTING UNDERGROUND UTILITY LOCATIONS ARE UNKNOWN. CONTRACTOR SHALL COORDINATE

PROPOSED ROUTING WITH WORK OF OTHER TRADES AND INCLUDE HAND DIGGING TO REDUCE

IMPACT ON EXISTING SYSTEMS. COORDINATE WITH OWNER AND FIELD VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO BEGINNING WORK. ANY EXISTING SYSTEMS (I.E. IRRIGATION, WATER, GAS, SEWER, ETC.) IMPACTED, SHALL BE REPAIRED/RESTORED TO ORIGINAL STATE.

2. RESTORE OR REPAIR ANY DISTURBED HARDSCAPE OR LANDSCAPE REQUIRED TO INSTALL NEW

WORK TO ITS ORIGINAL STATE UPON COMPLETION.

D. POWER:

1. PROVIDE CONCRETE PADS (MINIMUM 4" HIGH OR AS INDICATED) FOR ALL FLOOR MOUNTED

ELECTRICAL EQUIPMENT INSTALLED IN EQUIPMENT ROOMS AND IN AREAS SUSCEPTIBLE TO BEING

WET OR HOSED DOWN. SUBMIT PAD DETAIL PLANS INCLUDING DIMENSIONS FOR APPROVAL.

2. ALL DISCONNECT SWITCHES SHALL BE PAD-LOCKABLE IN THE "OFF" POSITION.

3. VERIFY AND COORDINATE EXACT LOCATION, POWER REQUIREMENTS AND METHOD OF

CONNECTION OF ALL MECHANICAL EQUIPMENT AND PERTINENT ITEMS AND DEVICES PRIOR TO

INSTALLATION OF ELECTRICAL SYSTEM.

4. PROVIDE A MINIMUM OF 12" SEPARATION BETWEEN POWER AND COMMUNICATION CONDUITS,

WHERE THEY ARE INSTALLED IN PARALLEL OR IN THE SAME TRENCH.

E. GROUNDING:

1. THE EQUIPMENT GROUNDING CONDUCTOR SHALL RUN CONTINUOUS FROM PANEL TO LAST OUTLET.

THIS WIRE SHALL BE PIGTAILED TO BOX AND DEVICE. ALL EQUIPMENT GROUNDING CONDUCTORS

SHALL BE INSULATED GREEN CONDUCTORS.

2. PROVIDE EQUIPMENT GROUNDING CONDUCTOR IN ALL BRANCH CIRCUITS.

3. BOXES WITH CONCENTRIC, ECCENTRIC OR OVER SIZED KNOCK-OUTS SHALL BE PROVIDED WITH

BONDING BUSHINGS AND JUMPERS. JUMPERS SHALL BE SIZED IN ACCORDANCE WITH NEC TABLE

250.122 AND LUGGED TO THE BOX.

GENERAL ELECTRICAL NOTES

F. PENETRATIONS:

1. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRESTOPPED WITH AN

APPROVED MATERIAL. SPACE BETWEEN PENETRATING MATERIALS (DESCRIBED BELOW) MUST BE

DESIGNED TO PREVENT THE SPREAD OF HOT FLAME OR GASES.

2. COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE THE WALLS OR PARTITIONS,

PROVIDED THEY ARE FIRESTOPPED USING UL LISTED ASSEMBLY.

3. OPENINGS FOR STEEL ELECTRICAL OUTLET BOXES NOT EXCEEDING 16 SQUARE INCHES ARE

PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100 SQUARE INCHES OR 100

SQUARE FEET OF WALL OF PARTITIONS. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR

PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.

G. IDENTIFICATION

1. REFER TO SPECIFICATIONS FOR IDENTIFICATION MATERIALS AND APPLICATION REQUIREMENTS.

2. ALL DISCONNECT DEVICES SHALL BE LABELED WITH VOLTAGE AND DEVICE BEING SERVED.

3. ALL EMPTY RACEWAYS SHALL BE IDENTIFIED WITH PROPOSED SERVICE AND LOCATION OF

OPPOSITE END OF RACEWAY. WHERE RACEWAYS ARE LOCATED BELOW GRADE PROVIDE BRASS

STAKE AND IDENTIFY LOCATION ON AS CONSTRUCTED DOCUMENTS WITH MEASUREMENTS FROM

BUILDING ELEMENTS OR GPS COORDINATES.

4. PAINT COUPLINGS, CONNECTORS AND ENTIRE CONDUIT WITHIN 6” OF JUNCTION BOX, CABINET OR

ENCLOSURE FOR THE FOLLOWING ELECTRICAL SYSTEMS:

a. NORMAL POWER – SILVER (UNPAINTED)

b. FIRE ALARM – RED

5. CONTRACTOR SHALL IDENTIFY ALL LOW VOLTAGE POWER CABLE FEEDERS IN PULL BOXES,

SWITCHBOARDS, PANELBOARDS AND AT ALL TERMINATIONS OF FEEDERS. EACH POWER CABLE

FEEDER TAG OR LABEL SHALL BE SECURELY FASTENED ON EACH FEEDER AND SHALL INCLUDE

FEEDER DESIGNATION AS SHOWN ON THE IDENTIFICATION NOTES. LABELS SHALL BE NON-

FERROUS TAGS OR PRESSURE SENSITIVE LABELS; VINYL CLOTH SELF-ADHESIVE, WRAP-AROUND TYPE; PRE-NUMBERED PLASTIC COATED OR WRITE-ON TYPE LABEL WITH CLEAR PLASTIC SELF-

ADHESIVE COVER FLAP. ACCEPTABLE MANUFACTURERS ARE BRADY, BUCHANAN, MIDLAND ROSS,

T&B, PANDUIT, OR APPROVED EQUAL.

H. COORDINATION

1. THERE IS NO ASSURANCE THAT THE LOCATION OF SUBSTRUCTURES SHOWN ON THIS DRAWING ARE ACCURATE, OR THAT ALL EXISTING SUBSTRUCTURES ARE SHOWN ON THESE DRAWINGS. THE

CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL SUBSTRUCTURES WHETHER SHOWN OR NOT.

ANY DAMAGE TO THE EXISTING SUBSTRUCTURES SHALL BE REPAIRED AT THE CONTRACTOR'S

EXPENSE.

2. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF ALL CONSTRUCTION DOCUMENT, FIELD

CONDITIONS AND WORK OF OTHER TRADES. BEFORE PROCEEDING WITH CONSTRUCTION, THE

CONTRACTOR VERIFY SHALL ROUGH-IN, VOLTAGE AND CONSTRUCTION REQUIREMENTS FOR ALL

ELECTRICAL CONNECTED COMPONENTS INCLUDING ITEMS PROVIDED BY OWNER OR OTHER

TRADES.

3. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONDUCTOR SIZES AND QUANTITIES WITH LUGS PROVISIONS AT ALL POINTS OF TERMINATION PRIOR TO RELEASE OF ELECTRICAL GEAR.

WHERE COORDINATION BETWEEN LUGS SIZES AND CONDUCTORS CAN NOT BE ACCOMMODATED

OR IS IMPRACTICAL, PROVIDE STEP-DOWN COMPRESSION ADAPTERS. CABLE PIN SIZE MAY NOT BE

REDUCED IN EXCESS OF ONE CABLE SIZE WITHOUT PRIOR APPROVAL.

4. REASONABLE EFFORTS HAVE BEEN MADE TO COORDINATE THE ELECTRICAL REQUIREMENTS OF THE EQUIPMENT SPECIFIED IN OTHER DIVISIONS WITH THE ELECTRICAL SYSTEMS SERVING THAT

EQUIPMENT. DIFFERENCES AMONG MANUFACTURERS OF EQUIPMENT MAKE IT IMPOSSIBLE TO

PRODUCE A SINGLE ELECTRICAL DESIGN WHICH WILL SATISFY THE VARYING ELECTRICAL

REQUIREMENTS OF THOSE MANUFACTURERS. CONSEQUENTLY, THE CONTRACTOR SHALL

COORDINATE THE ELECTRICAL REQUIREMENTS OF THE EQUIPMENT ACTUALLY FURNISHED ON THIS

PROJECT AND PROVIDE THE ELECTRICAL SYSTEMS REQUIRED BY THAT EQUIPMENT. THIS

COORDINATION EFFORT SHALL BE COMPLETED PRIOR TO THE INSTALLATION OF EITHER THE

EQUIPMENT OR THE ELECTRICAL SYSTEMS SERVING THAT EQUIPMENT.

5. CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE BUILDING CONTROL SYSTEMS FOR

120 VOLT POWER TO BUILDING CONTROL SYSTEMS COMPONENTS. REFERENCE MECHANICAL

SEQUENCE OF OPERATION AND COMMISSIONING DOCUMENTS FOR ADDITIONAL INFORMATION.

6. THE CONTRACTOR IS RESPONSIBLE FOR DISTRIBUTION OF COMPLETE CONSTRUCTION DOCUMENTS

TO OTHER TRADES AND SUPPLIERS UNDER THEIR JURISDICTION

7. ELECTRICAL WORKSPACE LAYOUTS ARE BASED UPON GENERIC EQUIPMENT SIZES. CONTRACTOR

IS RESPONSIBLE FOR MAINTAINING REQUIRED WORKING SPACE IN FRONT OF ALL GEAR BASED

UPON ACTUAL GEAR SIZES. IN ADDITION TO WORKING SPACE CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING DEDICATED ELECTRICAL SPACE ABOVE ALL ELECTRICAL EQUIPMENT. DEDICATED

ELECTRICAL SPACE IS TO BE CLEAR FOR 6 FOOT ABOVE EQUIPMENT OR TO THE STRUCTURE

WHICHEVER IS LOWER. NO PIPING, DUCTS, LEAK PROTECTION APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE LOCATED IN THE DEDICATED ELECTRICAL

ZONE.

J. DEMOLITION:

1. EXISTING CONDITIONS INDICATED ON DOCUMENTS ARE BASED UPON REVIEW OF AVAILABLE

RECORD DOCUMENTS AND VISUAL FIELD SURVEY AND ARE FOR REFERENCE ONLY. CONTRACTOR

SHALL VERIFY ACTUAL EXISTING CONDITIONS PRIOR TO COMMENCING WORK.

2. SURVEY EXISTING CONDITIONS, INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE

REMOVED AND REINSTALLED.

3. RECORD EXISTING CONDITION BY USE OF MEASURED DRAWINGS, PRECONSTRUCTION

PHOTOGRAPHS, AND/OR VIDEO TAPES. RECORD CONDITION OF AREAS ADJACENT TO DEMOLITION

IN ADDITION TO AREAS TO BE DEMOLISHED.

4. CONTRACTOR TO COORDINATE WITH OWNER PRIOR TO DEMOLITION. UTILIZE RECORD OF

EXISTING CONDITIONS REPORT TO DETERMINE WITH OWNERS INPUT ITEMS TO BE SALVAGED,

RECYCLED OR REUSED. WHILE REMOVING ITEMS USE CAUTION TO PREVENT DAMAGE TO

SALVAGED OR REUSED ITEMS OR STRUCTURE.

5. WHERE UTILITIES, FEEDERS, RACEWAYS PASS THROUGH AREAS OR WALLS TO BE DEMOLISHED, DETERMINE SOURCE, FUNCTION AND LOAD PRIOR TO DEMOLITION. IF THESE ARE SERVING AREAS OR LOADS THAT ARE TO REMAIN, PROVIDE PROVISIONS FOR RELOCATING PRIOR TO DEMOLITION.

6. AREAS OR LOADS THAT ARE TO REMAIN, PROVIDE PROVISIONS FOR RELOCATING PRIOR TO

DEMOLITION. SOURCE OR FIRST UP STREAM DEVICE TO REMAIN IN SERVICE.

7. REMOVE ALL ABANDONED RACEWAY, CABLES, AND EQUIPMENT FROM AREAS TO BE

DEMOLISHED/REMODELED UNLESS NOTED OTHERWISE. DEMOLITION TO INCLUDE POWER,

LIGHTING FIRE ALARM DEVICES AND RACEWAYS, COMMUNICATION DEVICES AND RACEWAYS, LOW

VOLTAGE AND CONTROL SYSTEMS.

8. WHERE RACEWAYS ENTER OR EXIT SLABS OR PARTITIONS TO REMAIN, CUT RACEWAYS FLUSH

WITH FINISH SURFACE, REMOVE CONDUCTORS AND PREPARE FOR REFINISH OF AREA.

9. VERIFY THAT ALL UTILITIES HAVE BEEN DISCONNECTED AND MADE SAFE PRIOR TO COMMENCING

DEMOLITION.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, RELOCATION OR PROTECTION OF ALL

ABOVE AND BELOW GROUND EXISTING IMPROVEMENTS.

K. AS CONSTRUCTED DOCUMENTS

1. CONTRACTOR IS RESPONSIBLE FOR KEEPING A COMPLETE SET OF CONSTRUCTION DOCUMENTS

SHOWING ACTUAL LOCATIONS, CIRCUITING INFORMATION, PRODUCT CATALOG NUMBERS,

DEVIATIONS AND CONCEALED LOCATIONS FOR WORK DIMENSIONED FROM CENTER OF COLUMNS

AND REFERENCED FLOOR HEIGHT. THESE AS CONSTRUCTED DOCUMENTS SHALL BE KEPT

UPDATED AND AVAILABLE ON SITE. UPON REQUEST THESE DOCUMENTS SHALL BE PROVIDED FOR

REVIEW BY THE ENGINEER WHILE ON SITE.

Kansas City

10561 Barkley Street, STE 100 Overland Park, KS 66212 t: +1 800.404.7677 e: hello@introba.com www.introba.com

© INTROBA, INC. 2025

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

The Professional Designer of Record (DOR), whose signature and personal seal appear on this document, assumes responsibility only for what appears hereon, and disclaims responsibility for all…