Attachment B-2 - Drawings - Bathrooms.pdf
PDF 201 KB Posted
- Solicitation number
- 19FR6326Q0073
- Issued by
-
Department of State US Embassy Paris
About this file
This is an architectural drawing for bathroom renovation work at Building 1 Boulogne in Paris, France, prepared by the United States Department of State's Bureau of Overseas Buildings Operations (OBO). The drawing is classified as UNCLASSIFIED and dated November 19, 2019, showing design at the 60% completion phase.
The drawing presents floor plans for four bathrooms across three design columns: Existing conditions, Project design modifications, and Electrical specifications. Master Bath 1, Bathroom 2, Bathroom 3, and Bathroom 4 are each depicted in multiple views showing current layouts and proposed renovations. The Electrical column details outlet placements, including outlets positioned at 1.20 meters from the floor, outlets behind radiators, and outlet locations at 1.20m from the floor. The document includes a legend identifying symbols for various fixtures including corner/outboard toilet, recessed toilet outline, shower floor demolition, radiator areas, toilet type symbols, shower model finishing, and other standard architectural notations. A title block identifies the project as "TYPE 5/2" with reference designation "CMP A-2." Further reproduction and distribution of this document is prohibited without express written permission from the OBO, and the drawing may not be altered without approval from the authorized individual.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Description
FINAL
1 2 3 4 5 6 7 8 109 11 12 13 14
A
B
C
D
Classification
Project Number
UNCLASSIFIED
Checked By
J.L. Merrant
Date
Drawn By
Sheet Number
Drawing Title
CADD File Name
OBO Project Number Phase
CADD Plot Scale
Drawing Scale
100%90%
35% 60%
CONCEPT
Release For Construction:
Revisions
A
B
C
D
F
E
G
H
I
Rev Number Date
J
K
L
6 754
United States Department of State
Washington, D.C.
12111098 1413
F
E
G
H
I
J
K
L
11.19.2019
S
ME
NA
M A
RE
CI
AB S RA
F
SI ,
EC
NA
R
PY-
Bureau Of Overseas Buildings Operation distribution is prohibited without the express written permission of: Bureau of
Overseas Buildings Operations, U.S. Department of State, Washington, DC, 20522-0620.
This document is the property of the U.S. Government. Further reproduction and/or
Information on this document is not to be altered except with the written approval of the individual whose seal appears hereon.
WARNING:
OBO/PDCS/PDC OBO/PDCS/DE
S
MASTER BATH 1
BATHROOM 3
BATHROOM 2
CLOSET
BATHROOM 4
MASTER BATH 1
BATHROOM 3
BATHROOM 2
CLOSET
BATHROOM 4
1 2
EXISTING PROJECT
MASTER BATH 1
BATHROOM 3
BATHROOM 2
CLOSET
BATHROOM 4
ELECTRICAL
S
S outlet at 1.20m from floor outlet at 1.20m from floor outlet behind radiator outlet behind radiator
S outlet behind radiator outlet at 1.20m from floor outlet at 1.20m from floor outlet behind radiator
S
AutoCAD SHX Text
CMP
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
BLDG 1 BOULOGNE
AutoCAD SHX Text
BATHROOMS RENOVATION
AutoCAD SHX Text
FRANCE
AutoCAD SHX Text Paris
AutoCAD SHX Text for
AutoCAD SHX Text A-2
AutoCAD SHX Text
TYPE 5/2
AutoCAD SHX Text mirror /cabimet/light model Aranga Line TW
AutoCAD SHX Text sink/cabinet model Doriane
AutoCAD SHX Text suspended toilet model Ona
AutoCAD SHX Text shower Ref AP90138401100
AutoCAD SHX Text shower screen model L2
AutoCAD SHX Text radiator Acova 500W
AutoCAD SHX Text bathtub type Xythos
AutoCAD SHX Text shower screen model URA
AutoCAD SHX Text switch
AutoCAD SHX Text outlet
AutoCAD SHX Text shower model Flight Neus
AutoCAD SHX Text sink model Instanbul
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .