This is a set of landscape drawings for the Sarasota Bayfront Park Bulkhead Replacement project in Sarasota, Florida, prepared by Cummins Cederberg Coastal & Marine Engineering as the prime consultant with Chen Moore & Associates as the landscape subconsultant. The drawings document the tree disposition plan, landscape plan, and irrigation plan for the project, which is divided into Phase 1 (covering Station 0+00 to 7+18) and Phase 2 (Station 7+18 to 15+00). The landscape scope includes protection and preservation of existing trees and palms, removal of 39 trees requiring mitigation, installation of 39 replacement trees totaling 145 inches of required diameter at breast height mitigation, tree preservation fencing totaling 207 linear feet (79 LF in Phase 1 and 128 LF in Phase 2), root pruning where construction activities conflict with tree root zones, and landscape restoration with sodding in disturbed areas. The landscape specifications establish detailed requirements for tree preservation practices, including root pruning performed eight weeks prior to construction by certified arborists, tree protection barricading maintaining 75 percent of the critical protection zone, canopy trimming per ANSI-A300 standards, and temporary irrigation throughout construction.
The irrigation plan encompasses restoration of existing irrigation zones in disturbed areas and new irrigation installation for proposed and relocated trees within the project limits, utilizing an existing reclaimed water system with three existing controllers (A, B, and G) remaining in place and connection to existing 2.5-inch mainlines. Phase 1 irrigation work includes 79 linear feet of tree preservation fencing, 1,137 linear feet of PVC Class 200 SDR 21 purple-coded lateral pipe, and 120.9 linear feet of PVC Schedule 40 pipe sleeves, while Phase 2 adds 128 linear feet of fencing, 1,855 linear feet of lateral pipe, and 107.5 linear feet of sleeves. Replacement plant material includes 39 trees (5 Gumbo Limbo, 15 Southern Live Oak varieties, and 19 other species), 39 shrubs, 372 shrub area plants, and approximately 50,000 square feet of St. Augustine grass sod restoration across both phases. All irrigation installation must comply with Florida Building Code Appendix F and Florida Irrigation Society standards, with contractor responsibility for system testing, pressure certification, 100 percent head-to-head coverage verification, and one-year warranty with as-built documentation signed by a Florida-registered landscape architect.
View the file
Other files for this state and local contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Lim it
EO
I
S
S
E
SS
41B
EXISTING
CONCRETE PAD
WITH SWING
EXISTING LIGHT POLE, TYP.
EXISTING CONCRETE SEAWALL
EXISTING CONCRETE SIDEWALK
SARASOTA BAY
F-101
D-100ROOT PRUNING,
TYP.
EXISTING
PATHWAYS TO
BE DEMO'ED
GRAND TREE
GRAND TREE PROTECTION
FENCING. SEE DETAIL1 ON
SHEET L-204.
PHASE DEMARCATION LINE
STA 7+18 REFER TO DRAWING
4/CM-4.2 FOR TRANSITION
STEP DOWN CONCEPT DETAIL
PHASE 1
PHASE 2
S S
S
UNK
UNK
RCW
E
UNK
RCW
UNK
RCW
E
UNK
UNK
E
UNK
UNK
UNK
UNK
RCW
S
D
D
12 13
161514
SARASOTA BAY
EXISTING LIGHT POLE, TYP.
EXISTING CONCRETE SEAWALL
EXISTING CONCRETE SIDEWALK
KEY MAP
MATCHLINE SEE SHEET NO. L-202
HWY 41
SARASOTA
BAY
L-201
LEGEND
SYMBOL DESCRIPTION
TREE OR PALM TO REMAIN
TREE OR PALM TO BE REMOVED
TREE ID NUMBER
TREE PROTECTION FENCING
TREE ROOT PRUNING
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V:
\P ro je ct s\
\2 5-
.0
Sa ra so ta
B ay
R es ilie nc y In iti at iv e
- B ay
\D es ig n\
C
AD
\S he et s\
-0
7.
TR
EE
D
IS
PO
SI
TI
O N
P
LA
N .d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
PARTIAL PLAN 1
PARTIAL PLAN 2
M A
TC
H
LI
N
E
SE
E
PA
R
TI
A L
PL
A
N
M A
TC
H
LI
N
E
SE
E
PA
R
TI
A L
PL
A
N
L-201
TREE DISPOSITION PLAN
1 INCH = FEET
GRAPHIC SCALE
10 20 40
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
D-100
F-101
PARTIAL PLAN 1
L-201
PARTIAL PLAN 2
L-202
PARTIAL PLAN 3
L-202
PARTIAL PLAN 4
RCW
RCW
RCW
E
RCW
UNK
E E
E
E
EXISTING LIGHT POLE, TYP.
EXISTING CONCRETE SEAWALL
EXISTING CONCRETE SIDEWALK
SARASOTA BAY
RCW
E
E RCW
E
E T
T
E
RCW
E
E
T
T
RCW
RCW
RCW
RCW
E
E
EE
W
W
94 91
EXISTING CONCRETE SEAWALL
EXISTING CONCRETE SIDEWALK
EXISTING BUILDING
EXISTING LIGHT POLE, TYP.
EXISTING GRASS AREA
EXISTING
CONCRETE PAD
WITH SCULPTURE
EXISTING CHAIN
LINK FENCE
EXISTING GATE
F-101
SARASOTA BAY
Project Lim it
NOTE THAT ROOT PRUNING IS NOT ANTICIPATED TO BE
NECESSARY HERE AS THE LIMITS OF FILL OR EXCAVATION
ARE NOT ANTICIPATED TO EXTEND TO THIS AREA. IF LIMITS
OF FILL, EXCAVATION OR GENERAL DISTURBANCE OF THE
EARTH NEAR THIS TREE, THEN ROOT PRUNING SHALL BE
CONDUCTED BEYOND THE LIMITS OF THE DRIPLINE PER THE
SPECIFICATIONS DETAILED HEREIN.
TREE PROTECTION
FENCING. SEE DETAIL 2
ON SHEET L-204.
Project Lim it
MATCHLINE SEE SHEET NO. L-201
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V:
\P ro je ct s\
\2 5-
.0
Sa ra so ta
B ay
R es ilie nc y In iti at iv e
- B ay
\D es ig n\
C
AD
\S he et s\
-0
7.
TR
EE
D
IS
PO
SI
TI
O N
P
LA
N .d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
PARTIAL PLAN 3
PARTIAL PLAN 4
KEY MAP
HWY 41
SARASOTA
BAY
MATCHLINE SEE PARTIAL PLAN 4
MATCHLINE SEE PARTIAL PLAN 3
LEGEND
SYMBOL DESCRIPTION
TREE OR PALM TO REMAIN
TREE OR PALM TO BE RELOCATED
TREE OR PALM TO BE REMOVED
TREE ID NUMBER
TREE PROTECTION FENCING
TREE ROOT PRUNING
L-202
TREE DISPOSITION PLAN
1 INCH = FEET
GRAPHIC SCALE
10 20 40
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
L-201
PARTIAL PLAN 1
L-201
PARTIAL PLAN 2
L-202
PARTIAL PLAN 3
L-202
PARTIAL PLAN 4
D-100
F-101
TREE ID
TREE SPECIES
(COMMON NAME) DBH (IN) CANOPY
SPREAD (FT.) DISPOSITION
CANOPY
AREA (S.F.)
GRAND TREE
OVER 24"
DBH
CONDITION
REQUIRED
REPLACEMENT
DBH (IN)
NUMBER OF
REPLACEMENT
TREES PER
REMOVED TREE
TOTAL
REQUIRED
REPLACEMENT
DBH (IN)
1 Silver Buttonwood 6 12 Remain 113 No Good 2 Black Olive 16 32 Remain 804 No Fair 3 Black Olive 14 28 Remain 616 No Fair 4 Black Olive 16 32 Remain 804 No Fair 5 Black Olive 22 44 Remain 1,521 No Fair 7 Live Oak 20 40 Remove 1,257 No Poor 5 2 10 8 Live Oak 18 36 Remove 1,018 No Fair 5 2 10 9 Live Oak 18 36 Remove 1,018 No Poor 5 2 10
10 Washingtonia Palm 10 20 Remain 314 No Good 11 Black Olive 16 32 Remain 804 No Fair 12 Black Olive 32 64 Remain 3,217 No Poor 13 Silver Buttonwood 6 12 Remain 113 No Fair 14 Live Oak 16 32 Remove 804 No Poor 5 2 10 15 Live Oak 15 30 Remove 707 No Fair 3 1 3 16 Live Oak 14 28 Remove 616 No Poor 3 1 3 17 Live Oak 15 30 Remove 707 No Good 3 1 3 18 Silver Buttonwood 6 12 Remain 113 No Fair 19 Black Olive 16 32 Remain 804 No Fair 20 Black Olive 10 20 Remain 314 No Poor 21 Black Olive 15 30 Remain 707 No Fair 22 Black Olive 22 44 Remain 1,521 No Poor 23 Black Olive 22 44 Remain 1,521 No Fair 24 Live Oak 15 30 Remove 707 No Poor 3 1 3 25 Live Oak 14 28 Remove 616 No Fair 3 1 3 26 Live Oak 16 32 Remove 804 No Poor 5 2 10 27 Black Olive 12 24 Remain 452 No Fair 28 Black Olive 20 40 Remain 1,257 No Poor 29 Live Oak 20 40 Remove 1,257 No Fair 5 2 10 30 Black Olive 12 24 Remain 452 No Fair 33 Montgomery Palm 12 24 Remove 452 No Fair 3 1 3 34 Washingtonia Palm 9 18 Remain 254 No Fair 35 Washingtonia Palm 10 20 Remain 314 No Fair 36 Washingtonia Palm 10 20 Remain 314 No Fair 37 Washingtonia Palm 10 20 Remain 314 No Fair 38 Royal Palm 8 16 Remove 201 No Poor 3 1 3 39 Royal Palm 10 20 Remove 314 No Poor 3 1 3 40 Royal Palm 10 20 Remove 314 No Poor 3 1 3
41 Coconut Palm 8 16 Remove 201 No Good 3 1 3 41b Thatch Palm 3 6 Remove 28 No Good 3 1 3 42 Coconut Palm 8 16 Remain 201 No Fair 43 Geiger Tree 4 8 Remove 50 No Fair 3 1 3 44 Cabbage Palm 9 18 Remain 254 No Good 45 Cabbage Palm 7 14 Remain 154 No Good 46 Cabbage Palm 9 18 Remain 254 No Good 47 Tababuia 13 26 Remain 531 No Fair 48 Tababuia 9 18 Remain 254 No Fair 49 Cabbage Palm 11 22 Remain 380 No Good 50 Cabbage Palm 10 20 Remain 314 No Good 51 Cabbage Palm 10 20 Remain 314 No Good 52 Cabbage Palm 10 20 Remain 314 No Good 53 Cabbage Palm 9 18 Remain 254 No Good 54 Cabbage Palm 11 22 Remain 380 No Good 55 Live Oak 17 34 Remain 908 No Poor 56 Cabbage Palm 9 18 Remain 254 No Good 57 Cabbage Palm 9 18 Remove 254 No Good 3 1 3 58 Cabbage Palm 7 14 Remove 154 No Good 3 1 3 59 Cabbage Palm 10 20 Remove 314 No Good 3 1 3 60 Cabbage Palm 9 18 Remove 254 No Good 3 1 3 62 Live Oak 16 32 Remove 804 No Poor 5 2 10 65 Cabbage Palm 9 18 Remove 254 No Good 3 1 3 66 Cabbage Palm 9 18 Remove 254 No Good 3 1 3 68 Cabbage Palm 6 12 Remove 113 No Good 3 1 3 72 Cabbage Palm 6 12 Remove 113 No Good 3 1 3 75 Cabbage Palm 10 20 Remain 314 No Good 76 Cabbage Palm 10 20 Remain 314 No Good 77 Cabbage Palm 8 16 Remain 201 No Good 78 Cabbage Palm 8 16 Remain 201 No Good 79 Cabbage Palm 8 16 Remain 201 No Good 81 Cabbage Palm 10 20 Remain 314 No Good 82 Cabbage Palm 9 18 Remain 254 No Good 83 Ficus 26 52 Remain 2,124 No Fair 85 Live Oak 6 12 Remain 113 No Fair 86 Banyan 5 10 Remove 79 No Fair 3 1 3 87 Banyan 14 28 Remove 616 No Fair 3 1 3 88 Black Olive 12 24 Remain 452 No Poor 89 Black Olive 14 28 Remain 616 No Poor 90 Black Olive 3 6 Remain 28 No Poor 91 Cabbage Palm 9 18 Remain 254 No Good 92 Cabbage Palm 6 12 Remain 113 No Good 93 Cabbage Palm 8 16 Remain 201 No Good 94 Cabbage Palm 9 18 Remain 254 No Good 95 Cabbage Palm 9 18 Remain 254 No Good 96 Cabbage Palm 9 18 Remain 254 No Good 97 Cabbage Palm 6 12 Remain 113 No Good 98 Banyan 10 20 Remove 314 No Fair 3 1 3 99 Banyan 10 20 Remove 314 No Fair 3 1 3
100 Banyan 7 14 Remove 154 No Fair 3 1 3 101 Mahogany 10 20 Remain 314 No Fair
TREE ID
TREE SPECIES
(COMMON NAME) DBH (IN) CANOPY
SPREAD (FT.) DISPOSITION
CANOPY
AREA (S.F.)
GRAND TREE
OVER 24"
DBH
CONDITION
REQUIRED
REPLACEMENT
DBH (IN)
NUMBER OF
REPLACEMENT
TREES PER
REMOVED TREE
TOTAL
REQUIRED
REPLACEMENT
DBH (IN)
Silver Buttonwood
120 Live Oak 42 42 Remain 1,385 Yes Good Within Limits of Work- subject to City grand tree protection requirements, *(DBH & canopy estimated, not surveyed)
121 Banyan 15 30 Remain 707 No Fair 122 Silver Buttonwood 6 12 Remain 113 No Fair 123 Silver Buttonwood 6 12 Remain 113 No Fair
TREES - SEE MITIGATION CHART FOR TOTAL DBH MITIGATED
TOTAL REPLACEMENT 3" DBH TREES REQUIRED 25
TOTAL REPLACEMENT 5" DBH TREES REQUIRED 14
TOTAL REPLACEMENT TREES REQUIRED 39
TOTAL REPLACEMENT DBH TO BE MITIGATED (IN) 145
Notes: Mitigation rate per Sarasota zoning code Section VII-322(2)b
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V:
\P ro je ct s\
\2 5-
.0
Sa ra so ta
B ay
R es ilie nc y In iti at iv e
- B ay
\D es ig n\
C
AD
\S he et s\
-0
7.
TR
EE
D
IS
PO
SI
TI
O N
P
LA
N .d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
PHASE 1 - TREE DISPOSITION CHART
L-203
TREE DISPOSITION
CHART
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
Grand Tree
NOTES:
TREE DISPOSITION CHART INCLUDES EXISTING TREE DATA FOR PHASES 1&2 OF SARASOTA BAY. TREE MITIGATION WILL BE INSTALLED
OVER BOTH PHASES OF THE PROJECT.
TREE MITIGATION REQUIREMENTS ARE BEING MET ACROSS ENTIRE SARASOTA BAY PROJECT SITE, THIS INCLUDES PHASES 1&2
PHASE 2 - TREE DISPOSITION CHART
CODE DESCRIPTION QTY
DEMOLITION
LIMITS OF ROOT PRUNING 88 LF
FENCE
TREE PRESERVATION FENCING 119 LF
D-100
F-101
REFERENCE NOTES SCHEDULE PHASE 1
CODE DESCRIPTION QTY DETAIL
FENCE
TREE PRESERVATION FENCING 79 LFF-101
REFERENCE NOTES SCHEDULE PHASE 2
TREE DISPOSITION NOTES
1. ROOT PRUNING AND WATERING PRIOR TO CONSTRUCTION:
1.1. TREE ROOT PRUNING AND TRIMMING, SHALL BE PERFORMED UNDER THE SUPERVISION OF A CERTIFIED & LICENSED
ARBORIST.
1.2. ROOT PRUNE TREES A MINIMUM OF EIGHT (8) WEEKS PRIOR TO CONSTRUCTION. PRIOR TO ROOT PRUNING, THOROUGHLY WATER THE ROOT ZONE WITH AT LEAST 2 TO 3 INCHES OF WATER FOR 2 TO 3 DAYS PRIOR TO ROOT
PRUNING. SEE BELOW FOR RELOCATION TIMELINE.
1.2.1. PROVIDE TEMPORARY IRRIGATION FOR EACH TREE THROUGHOUT THE DURATION OF CONSTRUCTION.
1.2.2. ROOT PRUNE TREES, SHOWN ON PLAN IN AREAS WHERE ROOTS WILL CONFLICT WITH CONSTRUCTION
ACTIVITY. PRUNING OF ROOTS SHOULD BE DONE IN A MANNER TO PRESERVE THE GREATEST AMOUNT OF THE
ROOT BASE AS POSSIBLE.
1.2.3. BACKFILL TRENCH WITH PLANTING SOIL.
1.2.4. FERTILIZE WITHIN THE ROOT ZONE (SEE NOTE 1.4).
1.3. ROOT PRUNING SHALL BE ACCOMPLISHED BY DIGGING A TRENCH AROUND THE TREE IN AREAS WHERE
PROPOSED SITE WORK WILL BE PERFORMED. TRENCHING SHALL BE AT A MINIMUM OF 24" DEEP. ROOT PRUNE
ONLY WITH A MECHANICAL ROOT-PRUNING SAW OR A TRENCHER WITH A MAXIMUM TRENCH WIDTH OF 8".
1.4. ALL EXPOSED ROOTS SHALL BE CUT OFF SMOOTHLY, WITH SHARP INSTRUMENTS. BACKFILL TRENCHES WITH SOIL
CONSISTING OF 30% SILICA SAND AND 70% MUCK. WATER THOROUGHLY AFTER ROOT PRUNING, AND ONCE
WEEKLY DURING THE ROOT REGENERATION PERIOD, WITH A SOLUBLE FERTILIZER THAT HAS A 20.20.20 ANALYSIS AT
MANUFACTURER'S RECOMMENDED RATE. WATERING, WITHOUT FERTILIZER, IS TO BE DONE DAILY.
2. BRACING AND GUYING OF TREES AFTER ROOT PRUNING
2.1. BRACING AND GUYING SHALL BE PROVIDED TO ASSURE THE TREES' STABILITY DURING THE ROOT REGENERATION
PERIOD; AS PER THE APPLICABLE DETAIL(S).
3. ROOT ZONE PROTECTION
3.1. DURING THE ENTIRE CONSTRUCTION PERIOD ALL REASONABLE EFFORTS SHALL BE MADE TO PROTECT THE ROOT
ZONE FROM DAMAGE. TREE PROTECTION BARRICADING SHALL BE ERECTED AROUND THE TREES. ALL PLANT
MATERIAL DESIGNATED TO BE SAVED, OR OUTSIDE OF THE LIMITS OF CONSTRUCTION, SHALL BE PROTECTED
DURING CONSTRUCTION WORK. WORK UNDER THESE ITEMS WILL INCLUDE CONSTRUCTION AND MAINTENANCE
OF TEMPORARY BARRICADE FENCING TO PROTECT THE ROOT ZONES OF EXISTING TREES AND OTHER PLANTINGS.
3.2. A PROTECTION BARRIER OR TEMPORARY FENCE OF AT LEAST 4 FEET IN HEIGHT SHALL BE INSTALLED AROUND EACH
TREE TO BE PROTECTED AND PRESERVED. THE TREE PROTECTION SHALL BE INSTALLED PRIOR TO THE ACTUAL
CONSTRUCTION START AND MAINTAINED FOR THE DURATION OF THE PROJECT.
3.3. TREE BARRICADE FENCING SHALL BE; AS PER THE APPLICABLE DETAIL(S).
NO DRIP LINE
ENCROACHMENT
NOTES:
CRITICAL PROTECTION ZONE: THE AREA
SURROUNDING A TREE WITHIN A CIRCLE
DESCRIBED BY A RADIUS OF ONE FOOT FOR
EACH INCH OF THE TREE TRUNK DIAMETER AT
54" ABOVE FINISHED GRADE. FOR GROUPS
OF TREES, PLACE BARRICADES BETWEEN
TREES AND CONSTRUCTION ACTIVITY.
*TREE PROTECTION BARRICADES SHALL BE
LOCATED TO PROTECT A MINIMUM OF 75%
OF THE CRITICAL PROTECTION ZONE.
ADJUST AS NECESSARY TO ACCOMMODATE
PROPOSED SITE IMPROVEMENTS; REFER TO
TREE DISPOSITION NOTES.
NO ENTRY OR STORAGE
DIMENSION VARIES PER CRITICAL
PROTECTION ZONE
4' MINIMUM/
8' MAXIMUM
O.C. SPACING
4' MIN.
2' MIN.
TREE DRIPLINE
SECURELY AFFIX FENCE TO STRINGER
WITH NAILS OR STAPLES (TYP.)
2"X4" STRINGER/TOP RAIL
4' HT. BARRICADE FENCE OF
ORANGE "TENSOR" HIGH
VISIBILITY MESH
2"X4" MIN. WOOD POST
EXISTING UNDISTURBED SOIL
TREE PRESERVATION FENCING
1/4" = 1'-0"
329343-24
ROOT PRUNING IS THE CUTTING OF ROOTS TO ACCOMMODATE THE PROPOSED INFRASTRUCTURE AND SITE
IMPROVEMENTS. IN INSTANCES WHERE ROOT PRUNING IS REQUIRED, THE WORK SHALL BE CONDUCTED BY OR UNDER THE
SUPERVISION OF AN ISA CERTIFIED ARBORIST. PRIOR TO ROOT PRUNING, THE TREES SHALL BE EVALUATED BY AN ISA
CERTIFIED ARBORIST TO DETERMINE WHETHER THE ROOT CUTTING WILL DESTABILIZE THE TREE OR CAUSE UNACCEPTABLE
DAMAGE TO THE TREE.
1. ROOTS MAY NOT BE TORN OFF WITH POWER EQUIPMENT, AND CUT ROOTS SHALL NOT BE LEFT WITH RIPPED, RAGGED
OR SHREDDED ENDS. ROOTS MUST BE CLEANLY SEVERED WITH SHARP HAND TOOLS OR POWER ROOT SAWS.
2. PRUNING TRENCHES SHALL BE BACKFILLED WITH NATIVE SOILS, FREE OF DEBRIS.
3. WHEN A ROOT WITH A DIAMETER OF TWO INCHES OR GREATER IS ENCOUNTERED, A FINAL CLEAN CUT SHALL BE
MADE WITH A SAW. THE CUT SHALL BE MADE FLUSH WITH THE SIDE OF THE TRENCH CLOSEST TO THE TREE.
4. WHEN ADJACENT TO NEW CURBING, UNCURBED PAVED AREAS, OR AREAS OF GRADE CHANGES, ROOTS SHALL BE
CUT NO MORE THAN 18 INCHES TOWARDS THE TREE FROM THE BACK OF THE CURB, THE EDGE OF THE PAVEMENT, OR THE POINT OF INTERSECTION OF OLD AND NEW GRADES, RESPECTIVELY. AFTER ROOT PRUNING, NO EXCAVATION
FOR THE INSTALLATION OF FORMS OR FOR ANY OTHER REASON MAY BE PERFORMED ANY CLOSER THAN SIX INCHES
OUTSIDE OF THE ROOT PRUNING CUT. THE ROOT PRUNING TRENCH SHALL BE BACKFILLED WITH NATIVE SOIL.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY TREES IN NEED OF SUPPLEMENTAL SUPPORT FOLLOWING
ROOT PRUNING. PRIOR TO COMMENCEMENT OF ROOT PRUNING, THE CONTRACTOR SHALL FURNISH A
SUPPLEMENTAL SUPPORT PLAN WHICH IDENTIFIES EACH TREE IN NEED OF TEMPORARY SUPPLEMENTAL SUPPORT AND
PROPOSE A STAKING/GUYING SYSTEM. THE CONTRACTOR SHALL INSTALL THE APPROVED SUPPORT SYSTEMS
IMMEDIATELY FOLLOWING ROOT PRUNING.
1. THE SCOPE OF THE WORK FOR MAY REQUIRE THE TRIMMING OF EXISTING TREE CANOPY TO ACCOMMODATE THE
PROPOSED SITE IMPROVEMENTS. IF CANOPY TRIMMING IS REQUIRED THE CONTRACTOR SHALL TRIM EXISTING TREES IN
ACCORDANCE WITH THE FOLLOWING:
2. CANOPY TRIMMING SHALL BE PERFORMED IMPLEMENTING ANSI-A300 (AMERICAN NATIONAL STANDARDS INSTITUTE)
PRUNING STANDARDS BY OR UNDER THE SUPERVISION OF AN ISA CERTIFIED ARBORIST. TRIMMING INCLUDES BOTH
HARDWOOD (DICOTYLEDON) AND PALM (MONOCOTYLEDON) SPECIES.
3. THE CONTRACTOR WILL ENSURE THAT ANY POTENTIAL CANOPY REDUCTION WILL BE KEPT TO A MINIMUM BY
REMOVING ONLY WHAT IS NECESSARY TO ACHIEVE THE REQUIRED CLEARANCES FOR THE INSTALLATION OF THE
PROPOSED SITE IMPROVEMENTS. WHEN THE PRUNING OF A BRANCH WILL RESULT IN THE REMOVAL OF ONE-HALF (1/2)
OF THE FOLIAGE ON THAT BRANCH, IT SHOULD BE REMOVED TO THE PARENT STEM. IF CANOPY REDUCTION WILL
RESULT IN A FOLIAGE LOSS GREATER THAN OR EQUAL TO ONE-QUARTER (1/4) OF ANY SINGLE TREE CANOPY, THE
CONTRACTOR WILL BE REQUIRED TO CONTACT THE PROJECT CEI AND CITY PROJECT REPRESENTATIVE PRIOR TO
TRIMMING. TREES THAT ARE PRUNED IN A MANOR INCONSISTENT WITH THE ANSI - A300 PRUNING STANDARDS
(INCLUDING BUT NOT LIMITED TO: IMPROPER PRUNING CUTS, EXCESSIVE CANOPY REDUCTION, HEADER CUTS, LION
TAILING, HAT RACKING OR TOPPING ) WILL REQUIRE THE REMOVAL AND MITIGATION OF THE SUBJECT TREE AT THE
CONTRACTOR'S EXPENSE AND MAYBE SUBJECT TO ADDITIONAL FINES AS DETERMINED BY THE GOVERNING ENTITY.
ROOT PRUNING NOTES
TREE CANOPY PRUNING NOTES
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V:
\P ro je ct s\
\2 5-
.0
Sa ra so ta
B ay
R es ilie nc y In iti at iv e
- B ay
\D es ig n\
C
AD
\S he et s\
-0
7.
TR
EE
D
IS
PO
SI
TI
O N
P
LA
N .d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
* QUANTITIES OF TREE PRESERVATION FENCING AND ROOT PRUNING ARE APPROXIMATE.
CONTRACTOR TO VERIFY PRIOR TO COMMENCEMENT OF CONSTRUCTION. ALL TREES SLATED
TO REMAIN SHALL BE PROTECTED IN PLACE PER THE DETAILS AND SPECIFICATIONS HEREIN.
GRAND TREE PROTECTION FENCING
1/4" = 1'-0"
DETAIL-FILE
L-204
TREE DISPOSITION
NOTES & DETAILS
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
W
W
W
W
W
W
W
W
W
W
W W
S
S
E
SS
SARASOTA BAY
PROPOSED WALKWAY
RAISED TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
PROPOSED CONCRETE
CAP TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
REINSTALL PIER, TYP.
(WORK COMPLETED BY
SUNTEX), TYP.
GRAND TREE TO REMAIN
PRESERVED IN PLACE.
PROPOSED HARDSCAPE SHALL
BE DESIGNED TO AVOID GRAND
TREE BASE BEYOND 20' RADIUS
TREE PROTECTION FENCING
AND MINIMIZE DISTURBANCE
TO THE ROOT ZONE.
EXISTING TREE TO REMAIN,
TYP.
EXISTING PALM TO REMAIN,
TYP.
EO
I
APPROXIMATE PROPOSED LIMIT OF FILL
AREA TO BE RESTORED WITH SOD.
LIMITS OF SOD RESTORATION SHALL BE
FIELD VERIFIED BY CONTRACTOR, TYP.
10' CANOPY TREE OFFSET FROM
WATER/WASTEWATER LINES
WITH ROOT BARRIER, TYP.
EG
HP
EG
CU
TF
TF
CU
TF
CU
TF
CR
CU
7 TF
EG
CU
SB
F-103 ROOT BARRIER, TYP.
CU
PROPOSED TIEBACK &
DEADMAN, TYP.
SEE PLANS BY OTHERS
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
PROPOSED
ADD/ALTERNATE
LANDSCAPE BEYOND
TREE MITIGATION
AND CODE MINIMUM
REQUIREMENTS, TYP.
PROPOSED ADD/ALTERNATE
LANDSCAPE BEYOND TREE
MITIGATION AND CODE MINIMUM
REQUIREMENTS, TYP.
PROPOSED ADD/ALTERNATE
LANDSCAPE BEYOND TREE
MITIGATION AND CODE MINIMUM
REQUIREMENTS, TYP.
PROPOSED ADD/ALTERNATE LANDSCAPE
BEYOND TREE MITIGATION AND CODE
MINIMUM REQUIREMENTS, TYP.
F-103ROOT BARRIER, TYP. 10' CANOPY TREE OFFSET
FROM WATER/WASTEWATER
LINES WITH ROOT BARRIER,
TYP.
5' PALM & UNDERSTORY
TREE OFFSET FROM
WATER/WASTEWATER LINES
WITH ROOT BARRIER, TYP.BL
EXISTING
WATER LINE,
TYP.
15' CANOPY TREE OFFSET
FROM WATER/WASTEWATER
LINES WITHOUT ROOT
BARRIER, TYP.
7.5' PALM & UNDERSTORY
TREE OFFSET FROM
WATER/WASTEWATER LINES
WITHOUT ROOT BARRIER, TYP.
QV-M
5' PALM & UNDERSTORY TREE
OFFSET FROM WATER/WASTEWATER
LINES WITH ROOT BARRIER, TYP.
PHASE DEMARCATION LINE
STA 7+18 REFER TO DRAWING
4/CM-4.2 FOR TRANSITION
STEP DOWN CONCEPT DETAIL
PHASE 1
PHASE 2
EXISTING
SANITARY
SEWER, TYP.
MINIMUM 4' CLEARANCE
FROM TIEBACKS TO
PLANTING PIT
EXCAVATION, TYP.
PROPOSED SHIFT OF
SIDEWALK LOCATION AWAY
FROM GRAND LIVE OAK TREE
SEE CIVIL PLANS
W W W W W W W W W W W W W W W W W W W W W
W
W
W
W
W
W
S
S
UNK
UNK
RCW
E
UNK
RCW
UNK
RCW
E
UNK
UNK
E
UNK
UNK
UNK
UNK
RCW
S
D
D
SARASOTA BAY PROPOSED WALKWAY
RAISED TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
PROPOSED CONCRETE
CAP TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
REINSTALL PIER, TYP.
(WORK COMPLETED BY
SUNTEX), TYP.
APPROXIMATE PROPOSED LIMIT OF FILL
AREA TO BE RESTORED WITH SOD.
LIMITS OF SOD RESTORATION SHALL BE
FIELD VERIFIED BY CONTRACTOR, TYP.
FIELD ADJUST LIMITS OF FILL
NOT TO COVER CRITICAL ROOT
ZONE OF TREES SLATED TO BE
PRESERVED IN PLACE, TYP. EXISTING TREE TO REMAIN,
TYP.
EXISTING PALM TO REMAIN,
TYP.
10' CANOPY TREE OFFSET
FROM WATER/WASTEWATER
LINES WITH ROOT BARRIER,
TYP.
5' PALM & UNDERSTORY
TREE OFFSET FROM
WATER/WASTEWATER LINES
WITH ROOT BARRIER, TYP.
SP2
BL
BS-M
SP
QV2-M
SP
QV2-M
QV2-M
CD
SP
QV2-M
BL
CD
1 CD
QV2-M
F-103ROOT BARRIER, TYP.
F-103ROOT BARRIER, TYP.
SOD TO BE RESTORED
IN DISTURBED AREAS,
TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
F-103 ROOT BARRIER, TYP.EXISTING
SANITARY
SEWER, TYP.
15' CANOPY TREE OFFSET
FROM WATER/WASTEWATER
LINES WITHOUT ROOT
BARRIER, TYP.
7.5' PALM & UNDERSTORY
TREE OFFSET FROM
WATER/WASTEWATER LINES
WITHOUT ROOT BARRIER, TYP.
PROPOSED TIEBACK &
DEADMAN, TYP.
SEE PLANS BY OTHERS
EXISTING
WATER LINE,
TYP.
BS-M
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
BL
W
S
EO
I
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V :\P ro je ct s\
\2 5-
.0
S ar as ot a B ay R es ili en cy
In iti at iv e
- B ay \D es ig n\ C
A D
\S he et s\
-0
7.
LA
N D
S C
A P
E P
LA
N
.d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
1 INCH = FEET
GRAPHIC SCALE
10 20 40
PARTIAL PLAN 1
PARTIAL PLAN 2
KEY MAP
HWY 41
SARASOTA
BAY
M A
TC
H
LI
N
E
SE
E
PA
R
TI
A L
PL
A
N
M A
TC
H
LI
N
E
SE
E
PA
R
TI
A L
PL
A
N
MATCHLINE SEE SHEET NO. L-302 L-301
LANDSCAPE PLAN
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
L-301
PARTIAL PLAN 1
L-301
PARTIAL PLAN 2
L-302
PARTIAL PLAN 3
L-302
PARTIAL PLAN 4
SYMBOL DESCRIPTION
TREE OR PALM TO REMAIN
ROOT BARRIER
SYMBOL CODE COMMON NAME
TREES
BL BLACK OLIVE
SP CABBAGE PALMETTO
CD GREEN BUTTONWOOD
CR PITCH APPLE
MITIGATION
BS-M GUMBO LIMBO
QV-M SOUTHERN LIVE OAK
QV2-M SOUTHERN LIVE OAK
SHRUBS
HP FIREBUSH
CU SEA GRAPE
SHRUB AREAS
EG BLUE DAZE
TF DWARF FAKAHATCHEE GRASS
SB SAND CORDGRASS
TURF
SOD ST. AUGUSTINE GRASS
PLANT LEGEND
F-103
1. IN AREAS WHERE EXISTING TREES ARE BEING REMOVED AND NEW TREES ARE BEING PLANTED, THE CONTRACTOR SHALL OVER-EXCAVATE THE PLANTING PITS BY A MINIMUM OF 6' DIAMETER X 3' DEPTH PLANTING PIT. NO EXISTING UTILITY LINES SHALL BE DAMAGED AS A RESULT OF THIS
EXCAVATION.
2. WHILE THE CITY REQUESTS A MINIMUM 6' DIAMETER PLANTING PIT, DETAIL #1/ SHEET L-303 MUST STILL BE OBSERVED, WHICHEVER IS GREATER. FOR EXAMPLE, THE 5" CALIPER LIVE OAKS ARE ESTIMATED TO HAVE A LARGER ROOT BALL. IN ORDER TO ACHIEVE A PLANTING PIT AT A MINIMUM 2X THE WIDTH OF THE ROOT BALL, THE PIT MAY BE LARGER THAN 6', AT WHICH TIME, THE ULTIMATE EXCAVATION
DISTANCE SHALL STILL REMAIN 4' AWAY FROM ANY TIEBACKS/ TIE RODS.
3. THE EXACT LOCATIONS OF THE PROPOSED TREES ARE INTENDED FOR ILLUSTRATIVE PURPOSES ONLY.
THE FINAL FIELD LOCATION OF THE PROPOSED TREES SHALL RESPOND TO THE ABOVE NOTES #1 AND #2, AS WELL AS THE EXISTING UNDERGROUND UTILITY SETBACKS AS REQUIRED PER CITY CODE.
4. WITH RESPECT TO THE CITY'S WATER AND WASTEWATER LINES, A 15' SEPARATION FOR CANOPY TREES AND A 7.5' SEPARATION FROM PALM AND UNDERSTORY TREES IS REQUIRED. THE SEPARATION CAN BE REDUCED TO 10' AND 5' RESPECTIVELY IF A 4' DEPTH ROOT BARRIER IS INSTALLED. ANY NECESSARY ROOT BARRIER REQUIRED SHALL BE INSTALLED PER THE DETAILS HEREIN AND SHALL BE
QUANTIFIED BY THE CONTRACTOR.
GENERAL NOTES
W
W W
W W
W W
W W
W
W
RCW
RCW
RCW
E
RCW
UNK
E E
E
E
SARASOTA
BAY
PROPOSED WALKWAY
RAISED TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
PROPOSED CONCRETE
CAP TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
REINSTALL PIER, TYP.
(WORK COMPLETED BY
SUNTEX), TYP.
EXISTING PALM TO REMAIN,
TYP.
APPROXIMATE
PROPOSED LIMIT
OF FILL AREA TO
BE RESTORED
WITH SOD. LIMITS
OF SOD
RESTORATION
SHALL BE FIELD
VERIFIED BY
CONTRACTOR,
TYP.
BL
QV2-M
SP
CR
QV-M
BL
EG
EG
QV2-M
BS-M
HP
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
PROPOSED TIEBACK
& DEADMAN, TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
PROPOSED ADD/ALTERNATE
LANDSCAPE BEYOND TREE
MITIGATION AND CODE
MINIMUM REQUIREMENTS, TYP.
EG
SB
HP
TF
CU
CU
TF
MINIMUM 4' CLEARANCE FROM
TIEBACKS TO PLANTING PIT
EXCAVATION, TYP.
BS-M
BS-M
EXISTING TREE TO
REMAIN, TYP.
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
RCW
E
E RCW
E
E T
T
E
RCW
E
E
T
T
RCW
RCW
RCW
RCW
E
E
EE
EXISTING BUILDING
EXISTING GRASS AREA
EXISTING CHAIN
LINK FENCE
EXISTING GATE
SARASOTA BAY
PROPOSED WALKWAY
RAISED TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
PROPOSED CONCRETE
CAP TO EL. +4.0 NAVD.
SEE CIVIL PLANS, TYP.
REINSTALL PIER, TYP.
(WORK COMPLETED BY
SUNTEX), TYP.
EXISTING TREE TO REMAIN,
TYP.
EXISTING PALM TO REMAIN,
TYP.
FIELD ADJUST LIMITS OF FILL
NOT TO COVER CRITICAL ROOT
ZONE OF TREES SLATED TO BE
PRESERVED IN PLACE, TYP.
APPROXIMATE PROPOSED LIMIT OF FILL
AREA TO BE RESTORED WITH SOD.
LIMITS OF SOD RESTORATION SHALL BE
FIELD VERIFIED BY CONTRACTOR, TYP.
APPROXIMATE PROPOSED LIMIT OF FILL
AREA TO BE RESTORED WITH SOD.
LIMITS OF SOD RESTORATION SHALL BE
FIELD VERIFIED BY CONTRACTOR, TYP.
CD
CR
BS-M
EG
QV2-M
SB
QV2-M
QV-M
EG
SP
CR
QV-M
BS-M
BS-M
PROPOSED TIEBACK
& DEADMAN, TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
SOD TO BE
RESTORED IN
DISTURBED
AREAS, TYP.
PROPOSED ADD/ALTERNATE
LANDSCAPE BEYOND TREE
MITIGATION AND CODE
MINIMUM REQUIREMENTS, TYP.
PROPOSED ADD/ALTERNATE
LANDSCAPE BEYOND TREE
MITIGATION AND CODE
MINIMUM REQUIREMENTS, TYP.
MINIMUM 4' CLEARANCE
FROM TIEBACKS TO
PLANTING PIT
EXCAVATION, TYP.
W
W W W W
W
W
W
W
W W
W
S
EO
I
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S-X
0GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V :\P ro je ct s\
\2 5-
.0
S ar as ot a B ay R es ili en cy
In iti at iv e
- B ay \D es ig n\ C
A D
\S he et s\
-0
7.
LA
N D
S C
A P
E P
LA
N
.d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
PARTIAL PLAN 3
PARTIAL PLAN 4
KEY MAP
HWY 41
SARASOTA
BAY
MATCHLINE SEE SHEET NO. L-301
MATCHLINE SEE PARTIAL PLAN 4
MATCHLINE SEE PARTIAL PLAN 3
L-302
LANDSCAPE PLAN
1 INCH = FEET
GRAPHIC SCALE
10 20 40
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
L-301
PARTIAL PLAN 1
L-301
PARTIAL PLAN 2
L-302
PARTIAL PLAN 3
L-302
PARTIAL PLAN 4
1. IN AREAS WHERE EXISTING TREES ARE BEING REMOVED AND NEW TREES ARE BEING PLANTED, THE CONTRACTOR SHALL OVER-EXCAVATE THE PLANTING PITS BY A MINIMUM OF 6' DIAMETER X 3' DEPTH PLANTING PIT. NO EXISTING UTILITY LINES SHALL BE DAMAGED AS A RESULT OF THIS
EXCAVATION.
2. WHILE THE CITY REQUESTS A MINIMUM 6' DIAMETER PLANTING PIT, DETAIL #1/ SHEET L-303 MUST STILL BE OBSERVED, WHICHEVER IS GREATER. FOR EXAMPLE, THE 5" CALIPER LIVE OAKS ARE ESTIMATED TO HAVE A LARGER ROOT BALL. IN ORDER TO ACHIEVE A PLANTING PIT AT A MINIMUM 2X THE WIDTH OF THE ROOT BALL, THE PIT MAY BE LARGER THAN 6', AT WHICH TIME, THE ULTIMATE EXCAVATION
DISTANCE SHALL STILL REMAIN 4' AWAY FROM ANY TIEBACKS/ TIE RODS.
3. THE EXACT LOCATIONS OF THE PROPOSED TREES ARE INTENDED FOR ILLUSTRATIVE PURPOSES ONLY.
THE FINAL FIELD LOCATION OF THE PROPOSED TREES SHALL RESPOND TO THE ABOVE NOTES #1 AND #2, AS WELL AS THE EXISTING UNDERGROUND UTILITY SETBACKS AS REQUIRED PER CITY CODE.
4. WITH RESPECT TO THE CITY'S WATER AND WASTEWATER LINES, A 15' SEPARATION FOR CANOPY TREES AND A 7.5' SEPARATION FROM PALM AND UNDERSTORY TREES IS REQUIRED. THE SEPARATION CAN BE REDUCED TO 10' AND 5' RESPECTIVELY IF A 4' DEPTH ROOT BARRIER IS INSTALLED. ANY NECESSARY ROOT BARRIER REQUIRED SHALL BE INSTALLED PER THE DETAILS HEREIN AND SHALL BE
QUANTIFIED BY THE CONTRACTOR.
GENERAL NOTES
SYMBOL DESCRIPTION
TREE OR PALM TO REMAIN
ROOT BARRIER
SYMBOL CODE COMMON NAME
TREES
BL BLACK OLIVE
SP CABBAGE PALMETTO
CD GREEN BUTTONWOOD
CR PITCH APPLE
MITIGATION
BS-M GUMBO LIMBO
QV-M SOUTHERN LIVE OAK
QV2-M SOUTHERN LIVE OAK
SHRUBS
HP FIREBUSH
CU SEA GRAPE
SHRUB AREAS
EG BLUE DAZE
TF DWARF FAKAHATCHEE GRASS
SB SAND CORDGRASS
TURF
SOD ST. AUGUSTINE GRASS
PLANT LEGEND
F-103
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V :\P ro je ct s\
\2 5-
.0
S ar as ot a B ay R es ili en cy
In iti at iv e
- B ay \D es ig n\ C
A D
\S he et s\
-0
7.
LA
N D
S C
A P
E P
LA
N
.d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
2"
SOD PLANTING
1 1/2" = 1'-0"
2 3
SOD (AS SPECIFIED)1
PLANTING MIX:
80% SILICA SAND, 20% ORGANIC
SIDEWALK OR CURB3
SUB-BASE4
NATIVE SOIL5
329301-03
LARGE TREE STAKING DETAIL
3/8" = 1'-0"
120°
2"X4" WOOD BRACE AT EQUAL SPACING
(3 PER TREE)
3" LAYER OF SPECIFIED MULCH: DO NOT
INSTALL WITHIN 3" OF TREE TRUNK
CONSTRUCT TEMPORARY 3" WATERING BASIN3
2X DIAMETER OF THE ROOTBALL.4
TREE TRUNK5
ROOTBALL6
TREE CANOPY7
329301-22
L-303
LANDSCAPE DETAILS
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
"COMMAND" SOIL
SABAL PALM PLANTING
1/4" = 1'-0"
DO NOT HURRICANE CUT FRONDS1
UNTIE FRONDS PRIOR TO INSPECTION2
METAL STRAPS SECURING 2"x4" WOOD
BATTENS. MIN. 5 LAYERS BURLAP. TOE NAIL
BRACES TO 2"X4" WOOD BATTENS: DO NOT
NAIL STAKES DIRECTLY TO TRUNK
2"X4" WOOD BRACE AT EQUAL SPACING
(3 PER TREE)
1/2"x2' FLUORESCENT MARKER5
FINISH GRADE6
3" LAYER OF SPECIFIED MULCH: DO NOT
INSTALL WITHIN 3" OF TREE TRUNK
FERTILIZER TABLET IF APPLICABLE8
CONSTRUCT TEMPORARY 3" WATERING
BASIN
2"X4"X8" STAKE: SET 2" BELOW FINISH
GRADE
BACKFILL WITH SPECIFIED SOIL MIX11
EXISTING SOIL12
2X DIAMETER OF THE ROOTBALL13
SET CROWN OF ROOT BALL 0'-2" ABOVE
SURROUNDING FINISH GRADE. REMOVE
TOP 2/3 OF BURLAP FROM ROOTBALL:
TRUNK TAPER SHALL BE VISIBLE AT TIME OF
INSTALLATION
SET ROOTBALL ON UNDISTURBED SOIL15
CLEAR TRUNK: REFER TO PLANT SCHEDULE16
329343-21
ROOT BARRIER DETAIL
NTS DETAIL-FILE
SHRUB/GROUND COVER PLANTING & SPACING
1" = 1'-0"
EQ
UAL
EQ
UAL
EQUAL
EQUAL
SHRUB SPACING DETAIL PLAN
N.T.S.
SPACE PLANTINGS AS SPECIFIED
ROOTBALL (TYP.)
CANOPY (TYP.)
MULCH BED (TYP.)
ON CENTER SPACING (TYP.)
REFER TO PLANT SCHEDULE
PLANT MATERIAL SHALL NOT BE PRUNED
PRIOR TO INSTALLATION: AFTER PLANTS
HAVE BEEN INSTALLED, EACH PLANT
SHALL BE PRUNED FOR UNIFORMITY
SET CROWN OF ROOT SLIGHTLY ABOVE
SURROUNDING FINISH GRADE: TRUNK
TAPER SHALL BE VISIBLE AT TIME OF
INSTALLATION
3" LAYER OF SPECIFIED MULCH: DO NOT
INSTALL WITHIN 3" OF TREE TRUNK
CONSTRUCT TEMPORARY 3" WATERING
BASIN
FINISH GRADE
FERTILIZER TABLET IF APPLICABLE.
BACKFILL WITH SPECIFIED SOIL MIX
EXISTING SOIL
2X DIAMETER OF THE ROOTBALL
329301-08
1. IN AREAS WHERE EXISTING TREES ARE BEING REMOVED AND NEW TREES ARE BEING PLANTED, THE CONTRACTOR SHALL OVER-EXCAVATE THE PLANTING PITS BY A MINIMUM OF 6' DIAMETER X 3' DEPTH PLANTING PIT. NO EXISTING UTILITY LINES SHALL BE DAMAGED AS A RESULT OF THIS
EXCAVATION.
2. WHILE THE CITY REQUESTS A MINIMUM 6' DIAMETER PLANTING PIT, DETAIL #1/ SHEET L-303 MUST STILL BE OBSERVED, WHICHEVER IS GREATER. FOR EXAMPLE, THE 5" CALIPER LIVE OAKS ARE ESTIMATED TO HAVE A LARGER ROOT BALL. IN ORDER TO ACHIEVE A PLANTING PIT AT A MINIMUM 2X THE WIDTH OF THE ROOT BALL, THE PIT MAY BE LARGER THAN 6', AT WHICH TIME, THE ULTIMATE EXCAVATION
DISTANCE SHALL STILL REMAIN 4' AWAY FROM ANY TIEBACKS/ TIE RODS.
3. THE EXACT LOCATIONS OF THE PROPOSED TREES ARE INTENDED FOR ILLUSTRATIVE PURPOSES ONLY.
THE FINAL FIELD LOCATION OF THE PROPOSED TREES SHALL RESPOND TO THE ABOVE NOTES #1 AND #2, AS WELL AS THE EXISTING UNDERGROUND UTILITY SETBACKS AS REQUIRED PER CITY CODE.
4. WITH RESPECT TO THE CITY'S WATER AND WASTEWATER LINES, A 15' SEPARATION FOR CANOPY TREES AND A 7.5' SEPARATION FROM PALM AND UNDERSTORY TREES IS REQUIRED. THE SEPARATION CAN BE REDUCED TO 10' AND 5' RESPECTIVELY IF A 4' DEPTH ROOT BARRIER IS INSTALLED. ANY NECESSARY ROOT BARRIER REQUIRED SHALL BE INSTALLED PER THE DETAILS HEREIN AND SHALL BE
QUANTIFIED BY THE CONTRACTOR.
GENERAL NOTES
CALIPER MEASUREMENTS NOTES:
1. CALIPER MEASUREMENT IS 6" FROM TOP OF ROOT BALL FOR TREES
WITH 6" CALIPER OR LESS.
2. CALIPER MEASUREMENT IS12" FROM TOP OF ROOT BALL FOR
TREES WITH 6" CALIPER GREATER.
REFER TO PLANT SCHEDULE FOR INDIVIDUAL SIZES.
LARGE TREE PLANTING DETAIL
1/4" = 1'-0"
DO NOT PRUNE CENTRAL LEADER1
PRUNE DAMAGED OR DEAD WOOD
IMMEDIATELY PRIOR TO PLANTING USING
ACCEPTABLE NURSERY PRACTICES OR AS
DIRECTED BY THE LANDSCAPE ARCHITECT
PROTECT TRUNK WITH 5 LAYERS OF BURLAP
MINIMUM
2"x4" WOOD BRACE AT EQUAL SPACING
(3 PER TREE). DO NOT PUNCTURE
ROOTBALL.
FLUORESCENT MARKING FLAG5
FINISH GRADE6
2" LAYER OF SPECIFIED MULCH: DO NOT
INSTALL WITHIN 3" OF TREE TRUNK
FERTILIZER TABLET IF APPLICABLE8
CONSTRUCT TEMPORARY 3" WATERING
BASIN.
2"X4"X8" STAKE: SET 2" BELOW FINISH GRADE10
SPECIFIED SOIL MIX11
EXISTING SOIL12
2X DIAMETER OF THE ROOTBALL13
SET CROWN OF ROOT BALL SLIGHTLY
ABOVE SURROUNDING FINISH GRADE.
REMOVE TOP 2/3 OF BURLAP FROM
ROOTBALL. TRUNK TAPER SHALL BE VISIBLE
AT TIME OF INSTALLATION
SET ROOTBALL ON UNDISTURBED SOIL15
REMOVE TOP 2/3 OF BURLAP/WIRE BASKET
FROM ROOTBALL
CLEAR TRUNK: REFER TO PLANT SCHEDULE17
* SEE NOTE REGARDING EXCAVATION FOR
TREE INSTALLATION - NO EXCAVATION FOR
TREE INSTALLATION SHALL COME WITHIN 4'
OF TIE RODS OR DEADMEN (SUPPORTING
STRUCTURES FOR SEAWALL).
P-SA-01
MITIGATION
BS-M 5 GUMBO LIMBO BURSERA SIMARUBA SEE SIZE 12` HT, 4` SPRD, 3" CAL YES MITIGATION TREE
QV2-M 7 SOUTHERN LIVE OAK QUERCUS VIRGINIANA SEE SIZE 12' HT, 4' SPRD, 5" CAL YES
SOD 22,620 ST. AUGUSTINE GRASS STENOTAPHRUM SECUNDATUM SOD FULL NO24,194 SF
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE NATIVE CODE REQUIREMENT
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE NATIVE
SHRUBS
CU 39 SEA GRAPE COCCOLOBA UVIFERA SEE SIZE 3` HT, FULL YES
SHRUB AREAS
TF 128 DWARF FAKAHATCHEE GRASS TRIPSACUM FLORIDANUM SEE SIZE 24" HT, FULL YES
BL 9 BLACK OLIVE BUCIDA BUCERAS SEE SIZE 12` HT, 4` SPRD, 3" CAL NO
CD 4 GREEN BUTTONWOOD CONOCARPUS ERECTUS SEE SIZE 12` HT, 4` SPRD, 3" CAL YES
SP 13 CABBAGE PALMETTO SABAL PALMETTO SEE SIZE 8`-12` CT, SLICK TRUNK YES
SPACING REMARKS SPACING REMARKS
BL 4 BLACK OLIVE BUCIDA BUCERAS SEE SIZE 12` HT, 4` SPRD, 3" CAL NO
CR 10 PITCH APPLE CLUSIA ROSEA SEE SIZE 10` HT, 4` SPRD, 2-1/2" CAL YES
CD 2 GREEN BUTTONWOOD CONOCARPUS ERECTUS SEE SIZE 12` HT, 4` SPRD, 3" CAL YES
SP 4 CABBAGE PALMETTO SABAL PALMETTO SEE SIZE 8`-12` CT, SLICK TRUNK YES
SHRUBS
CU 20 SEA GRAPE COCCOLOBA UVIFERA SEE SIZE 3` HT, FULL YES
HP 31 FIREBUSH HAMELIA PATENS SEE SIZE 3` HT, FULL YES
SHRUB AREAS
EG 244 BLUE DAZE EVOLVULUS GLOMERATUS SEE SIZE 12" HT, FULL NO
SB 72 SAND CORDGRASS SPARTINA BAKERI SEE SIZE 24" HT, FULL YES
TF 109 DWARF FAKAHATCHEE GRASS TRIPSACUM FLORIDANUM SEE SIZE 24" HT, FULL YES
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE NATIVE
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE NATIVE CODE REQUIREMENT
SOD 25,916 ST. AUGUSTINE GRASS STENOTAPHRUM SECUNDATUM SOD FULL NO28,607 SF
MITIGATION
BS-M 12 GUMBO LIMBO BURSERA SIMARUBA SEE SIZE 12` HT, 4` SPRD, 3" CAL YES MITIGATION TREE
QV-M 8 SOUTHERN LIVE OAK QUERCUS VIRGINIANA SEE SIZE 12` HT, 4` SPRD, 3" CAL YES
QV2-M 7 SOUTHERN LIVE OAK QUERCUS VIRGINIANA SEE SIZE 12' HT, 4' SPRD, 5" CAL YES
TURF
48" o.c. FULL TO BASE
48" o.c.
24" o.c.
30" o.c. FULLY ROOTED POT
30" o.c. FULLY ROOTED POT
CODE DESCRIPTION QTY
FENCE
ROOT BARRIER 277 LFF-103
REFERENCE NOTES SCHEDULE PHASE 1
CODE DESCRIPTION QTY
FENCE
ROOT BARRIER 13 LFF-103
REFERENCE NOTES SCHEDULE PHASE 2
48" o.c. FULL TO BASE
30" o.c. FULLY ROOTED POT
TREE MITIGATION CALCULATIONS
14" SQ. CONCRETEBATTER PILE
S-#
SECTION SYMBOL
BREAKLINE
SECTION TITLE
DETAIL TITLE
DETAIL LABEL
NORTH ARROW
REVISION DELTA
CC STANDARD DIM
CC STANDARDMINOR TEXT
CC STANDARDMAJOR TEXT CC STANDARDMAJOR TEXT
GRAPHIC SCALE
ELEV. +X.X' N-VDELEVATION SYMBOL
WATER LEVEL
SCALE: (11X17)
TITLE1 S-SCALE: (22X34)TITLE2 A
TITLE1TITLE2 #S-SCALE: (22X34)SCALE: (11X17)
S- X
0 GRAPHIC SCALE(22X34) 1" = X'(11X17) 1" = X'
XXX
RB
12600.01
1491 SECOND ST. SUITE E,
SARASOTA, FLORIDA 34236
TEL: 941-364-2425 FAX:
305-974-1969
WWW.CUMMINSCEDERBERG.COM
COA # 29062
SARASOTA BAYFRONT
PARK BULKHEAD
REPLACEMENT
CITY OF SARASOTA
5 BAYFRONT DR.
SARASOTA, FLORIDA 34236
JVH
IS
SU
E D
AT
E
S U
B M
IS
S
IO
N
R
E V
IS
IO
N
SHEET TITLE
SCALE
CHECKED
DRAWN
CC PROJECT NO:
SEAL:
PRIME CONSULTANT:
PROJECT:
CLIENT:
CUMMINS CEDERBERG
COASTAL & MARINE ENGINEERING
COA # 29062
V :\P ro je ct s\
\2 5-
.0
S ar as ot a B ay R es ili en cy
In iti at iv e
- B ay \D es ig n\ C
A D
\S he et s\
-0
7.
LA
N D
S C
A P
E P
LA
N
.d w g
ADDRESS:
ADDRESS:
1761 12th STREET
SARASOTA, FLORIDA 34236
P R
O G
R E
S S
S E
T
/3
/2
SCALES PERTAIN TO
24"x36" SHEET SIZE
FOR CITY ENGINEER'S USE ONLY
2520 TAMIAMI TRAIL, SUITE 15,
NOKOMIS, FL 34275
TEL:941-529-1907
WWW.CHENMOORE.COM
SUBCONSULTANT:
CHEN MOORE &
ASSOCIATES
0%
C O
N S
TR
U
C
TI
O N
D O
C U
M E
N T
S E
T /0
/2
L-304
LANDSCAPE SCHEDULE
TANYA L. MCCORMICK, RLA
LICENSE NO. 6667243
DATE: __________
THIS SEAL IS ONLY VALID ON PRINTED
COPIES THAT ARE DATED WITH THE
LICENSEE'S ORIGINAL HAND SIGNATURE.
SCANNED OR ELECTRONIC COPIES ARE NOT
CONSIDERED SIGNED AND SEALED.
LA 6667243TA
NYA L. MCCORMICK
RE
GIS
TERED LANDSCAPE ARCHITECT
F L O R I DA
STATE
OF
10/28/2025
* ACTUAL QUANTITY OF TURF TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. ALL AREAS OF DISTURBANCE SHALL BE REPLENISHED WITH SOD.
ALL SPECIFICATIONS FOR PLANT SIZING ARE CODE MINIMUMS AND ALL SPECIFICATIONS MUST BE MET AT A MINIMUM.
PHASE 1 - ADD/ALTERNATE PLANT LIST
PHASE 1 - MITIGATION PLANT LIST
NOTE: ADD/ALTERNATE PLANT SCHEDULE INCLUDES PLANT MATERIAL THAT IS ABOVE THE REQUIRED CODE MINIMUM
TREE MITIGATION AND SOD RESTORATION.
*TREE MITIGATION CALCULATIONS PROVIDED FOR ENTIRE PROJECT SITE.
TREES REQUIRED FOR TREE MITIGATION TO BE INSTALLED ACROSS PHASES
1&2 AS SHOWN ON PLANS
* ACTUAL QUANTITY OF TURF TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. ALL AREAS OF DISTURBANCE SHALL BE REPLENISHED WITH SOD.
ALL SPECIFICATIONS FOR PLANT SIZING ARE CODE MINIMUMS AND ALL SPECIFICATIONS MUST BE MET AT A MINIMUM.
PHASE 2 - ADD/ALTERNATE PLANT LIST
PHASE 2 - MITIGATION PLANT LIST
NOTE: ADD/ALTERNATE PLANT SCHEDULE INCLUDES PLANT MATERIAL THAT IS ABOVE THE REQUIRED CODE MINIMUM
TREE MITIGATION AND SOD RESTORATION.
1. THESE PLANS ARE BEING LET AS PHASE 1 AND PHASE 2. THE CONTRACTOR IS RESPONSIBLE FOR, AND REQUIRED TO HAVE A LICENSED PROFESSIONAL LANDSCAPE ARCHITECT PREPARE THE DESIGN OF THE LANDSCAPING AND PROPOSED WORK, FOR TRANSITIONING THE PROPOSED PHASE 1 WORK TO THE EXISTING CONDITIONS AT STA 7+18 (REFER TO DETAIL 4/CM-4.2). THE CONTRACTOR IS TO SUBMIT THE PROPOSED DESIGN FOR REVIEW AND ACCEPTANCE BY THE LANDSCAPE ARCHITECT OF RECORD, PRIOR
TO CONSTRUCTION.
2. THE CONTRACTOR IS TO COORDINATE THE UPLAND CIVIL AND UTILITIES TRANSITION DESIGN WITH THE OTHER DISCIPLINES (THE CIVIL DESIGN OF THE BULKHEAD REPLACEMENT, ELECTRICAL ENGINEERING, AND LANDSCAPE ARCHITECTURE) SO THAT THERE IS NO CONFLICT WITH THOSE PHASE 1 DESIGNS, NOR THE
PHASE 2 BUILD OUT DESIGN).
3. THE DESIGN SHALL BE IN COMPLIANCE WITH THE CRITERIA PRESENTED ON DRAWING L-303 AND THE DETAILS INCLUDED IN THIS PLAN SET AS WELL AS ALL APPLICABLE REGULATORY AGENCY REQUIREMENTS;
INCLUDING THE CITY OF SARASOTA AND SARASOTA COUNTY, THAT ARE IN EFFECT AT THE TIME OF
LETTING.
PHASING NOTES
1. GENERAL
1.1. WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING:
1.2. THESE GENERAL NOTES, CONSTRUCTION DOCUMENTS AND SPECIFICATIONS.
1.3. ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES AND REGULATIONS.
1.4. SOURCE OF BASE INFORMATION IS PROVIDED BY GEORGE F. YOUNG INC. ON 04-01-2025 AND IS
ASSUMED TO BE CORRECT. IF SITE DISCREPANCIES ARE PRESENT, CONTRACTOR SHALL NOTIFY
OWNER'S REPRESENTATIVE IMMEDIATELY. IF CONTRACTOR CONTINUES WORK WITHOUT THE PROPER
NOTIFICATION, CONTRACTOR DOES SO AT HIS OWN RISK.
1.5. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, SUPERVISION, AND EQUIPMENT REQUIRED
FOR THE WORK AS SHOWN ON THE CONSTRUCTION DOCUMENTS DESCRIBED HEREIN.
1.6. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COORDINATION WITH SUB-CONTRACTORS AS
REQUIRED TO COMPLETE THE WORK OF THIS PROJECT.
1.7. CONTRACTOR SHALL VERIFY LOCATIONS OF PERTINENT SITE IMPROVEMENTS INSTALLED UNDER OTHER CONTRACTS. IF ANY PART OF THIS PLAN CANNOT BE FOLLOWED DUE TO SITE CONDITIONS, CONTACT OWNER'S REPRESENTATIVE FOR INSTRUCTIONS PRIOR TO COMMENCING WORK.
1.8. CONTRACTOR TO NOTIFY "SUNSHINE STATE ONE CALL OF FLORIDA, INC." AT 1-800-432-4770 TWO
FULL BUSINESS DAYS PRIOR TO DIGGING FOR UNDERGROUND UTILITY LOCATIONS.
1.9. CONTRACTOR IS RESPONSIBLE FOR DETERMINING ALL UTILITY LOCATIONS AND INSTALLING FACILITIES SO AS TO NOT CONFLICT. THE LOCATION OF EXISTING UTILITIES OR SITE FEATURES AS SHOWN ON THE PLANS MAY VARY IN RELATION TO ACTUAL EXISTING CONDITIONS. ANY DIFFERING SITE CONDITIONS FROM THAT WHICH IS REPRESENTED HEREON, WHETHER ABOVE, ON OR BELOW THE SURFACE OF THE GROUND, SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE LANDSCAPE ARCHITECT AND
THE OWNER IN WRITING. NO CLAIM FOR EXPENSES INCURRED BY THE CONTRACTOR DUE TO
DIFFERING SITE CONDITIONS WILL BE ALLOWED IF THE CONTRACTOR FAILS TO PROVIDE THE
REQUIRED WRITTEN NOTIFICATION OF SUCH CONDITIONS FOR REVIEW BY THE LANDSCAPE
ARCHITECT AND THE OWNER.
1.10. CONTRACTOR SHALL NOTIFY ALL APPROPRIATE UTILITY COMPANIES OF PROPOSED START OF WORK IN ACCORDANCE WITH THEIR STANDARD REQUIREMENTS, INCLUDING BUT NOT LIMITED TO, WATER, SANITARY SEWER, POWER, NATURAL GAS, TELEPHONE AND CABLE TV COMPANIES.
1.11. IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO TAKE THE NECESSARY PRECAUTIONS TO ENSURE PROPER SAFETY AND WORKMANSHIP WHEN WORKING IN THE VICINITY OF EXISTING UTILITY
LINES.
1.12. PERFORM EXCAVATION IN THE VICINITY OF UNDERGROUND UTILITIES WITH CARE AND BY HAND, IF NECESSARY. THE CONTRACTOR BEARS FULL RESPONSIBILITY FOR THIS WORK AND DISRUPTION OF DAMAGE TO UTILITIES SHALL BE REPAIRED IMMEDIATELY AND AT NO EXPENSE TO THE OWNER.
1.13. THE SUCCESSFUL BIDDER SHALL FURNISH TO THE OWNER A UNIT PRICE BREAKDOWN FOR ALL MATERIALS. THE OWNER MAY, AT ITS DISCRETION, ADD OR DELETE FROM THE MATERIALS UTILIZING
THE UNIT PRICE BREAKDOWN SUBMITTED.
1.14. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL REQUIRED PERMITS ARE OBTAINED AND ARE IN HAND AT THE JOB SITE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
CONTRACTOR SHALL ABIDE BY ALL PERMIT CONDITIONS.
2. PRE-CONSTRUCTION RESPONSIBILITY
2.1. UPON RECEIPT OF NOTICE OF AWARD, THE CONTRACTOR SHALL ARRANGE A PRE-CONSTRUCTION
CONFERENCE TO INCLUDE ALL INVOLVED GOVERNMENTAL AGENCIES, ALL AFFECTED UTILITY
OWNERS, THE OWNER, THE LANDSCAPE ARCHITECT, ANY OTHER PERTINENT PARTIES AND HIMSELF.
2.2. CONTRACTOR SHALL PROVIDE TEMPORARY SANITARY FACILITIES ONSITE. LOCATION TO BE
DETERMINED BY THE OWNER. JANITORIAL SERVICES SHALL BE PROVIDED BY CONTRACTOR
THROUGHOUT THE DURATION OF PROJECT.
2.3. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE SIZE, LOCATION, ELEVATION, AND MATERIAL OF ALL EXISTING UTILITIES WITHIN THE AREA OF CONSTRUCTION.
2.4. IF UPON EXCAVATION, AN EXISTING UTILITY IS FOUND TO BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION OR TO BE OF A SIZE OR MATERIAL DIFFERENT FROM THAT SHOWN ON THE PLANS;
THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT.
2.5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAKE ARRANGEMENTS FOR THE FIELD LOCATIONS AND FOR ANY TREES PROPOSED FOR RELOCATION. THIS SHALL BE DONE IN A TIMELY
MANNER TO MINIMIZE IMPACT ON CONSTRUCTION SCHEDULE. ANY DELAY CAUSED BY THE
CONTRACTOR BY THE RELOCATION OF TREES SHALL BE INCIDENTAL TO THE CONTRACT AND NO
EXTRA COMPENSATION WILL BE ALLOWED.
2.6. CONTRACTOR SHALL VERIFY LIMITS OF CONSTRUCTION AS NOTED ON THE PLANS. ANY WORK
PERFORMED OUTSIDE OF THE AGREED UPON LIMITS OF CONSTRUCTION SHALL BE DONE AT THE
EXPENSE OF THE CONTRACTOR.
3. SITE DEMOLITION
3.1. ITEMS SHALL REMAIN UNLESS OTHERWISE NOTED ON THE PLAN(S). REMOVE DESIGNATED ITEMS
SHOWN ON THE PLAN TO THE FULL DEPTH OF THEIR CONSTRUCTION UNLESS OTHERWISE NOTED.
3.2. ALL HARDSCAPE DESIGNATED FOR REMOVAL SHALL BE SAW CUT, LEAVING UNIFORM EDGES TO THE GREATEST EXTENT POSSIBLE. MATERIAL EDGES TO REMAIN SHALL BE SHORED UP AND PROTECTED
DURING CONSTRUCTION TO PRESERVE EDGE INTACT. REPAIRS TO DAMAGED EDGES SHALL BE
REPAIRED BY CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
3.3. NO EXISTING MATERIAL SHALL BE USED IN NEW CONSTRUCTION UNLESS NOTED ON THE PLANS OR
APPROVED DURING THE SHOP DRAWING APPROVAL PROCESS.
3.4. SALVAGE EXISTING MATERIALS AS INDICATED ON THE PLANS. SALVAGED MATERIALS SHALL BE HANDLED WITH CARE AND STORED ON-SITE OR AS DIRECTED BY OWNER. CLEAN ALL DEBRIS AND
CONSTRUCTION MATERIAL FROM SALVAGED ITEMS; REUSE AS DIRECTED BY OWNER'S
REPRESENTATIVE.
3.5. REMOVE DEMOLISHED MATERIALS FROM SITE AND DISPOSE OF AS REQUIRED BY LOCAL, STATE OR
FEDERAL LAWS.
3.6. CONTRACTOR SHALL PROTECT ADJACENT WATER BODIES, COASTAL DUNE SYSTEMS AND
PROPERTIES FROM DAMAGE BY SEDIMENTATION OR OTHER POTENTIAL CONSTRUCTION RELATED
CAUSES.
3.7. ALL IRRIGATION IN DEMOLITION AREA TO BE CAPPED AND ADJUSTED AS NECESSARY TO ENSURE
OVERALL SYSTEM IS NOT AFFECTED.
4. TREE PRESERVATION
4.1. ALL TREES TO BE PRESERVED AS INDICATED ON THE TREE DISPOSITION PLAN SHALL BE PROTECTED BY
A…