Attachment_A.3_Electrical_Drawings.pdf
PDF 12 MB Posted
- Attached to
- Bayfront Park Seawall Reconstruction State and local contract opportunity
- Solicitation number
- 26-14JS
- Issued by
- Sarasota County, Siesta Key CDP, Florida
About this file
Electrical Drawings Summary
This is a set of electrical drawings (Attachment A.3) prepared by Florida Professional Engineer Daniel Diez for the Bayfront Park Seawall Reconstruction project at Marina Jack in Sarasota, Florida. The electrical scope includes installation of new conduit systems, conductor replacements, marina power pedestal elevation modifications, electrical safety signage, grounding systems, and bonding work to comply with the 2023 Florida Building Code (adopting the 2020 National Electrical Code). The project encompasses two phases: Phase 1 addresses slips A-1 through A-37 served by Load Center 'B' (Electrical Disconnect 'B'), while Phase 2 addresses slips A-38 through A-66 served by Load Centers 'A' and 'C'. The electrical work involves installation of multiple new 2.5-inch and 3-inch PVC-coated rigid galvanized steel conduits ranging from 30 to 45 linear feet, with feeder circuits containing 3/0 AWG phase conductors, 3/0 AWG neutral conductors, and #2 or #3 AWG ground conductors. All electrical equipment, connections, and pedestals must be raised above the electrical datum plane (2 feet above highest tide level), and all conductor materials must be copper with marine-grade insulation (XLPE, PTFE, or PFA). The contractor is responsible for thorough field investigation and verification of existing electrical infrastructure, replacement of any damaged or non-compliant equipment, coordination with FPL utility company for transformer elevation, and installation of permanent electrical safety warning signs throughout marina approaches.
Key technical requirements mandate compliance with all applicable codes and FDOT standards, use of ETL or UL-listed materials only, color-coded phase wiring maintained to points of utilization, and separation of control and power circuit conductors in distinct conduits. The contractor must perform a 3-point fall-of-potential ground resistance test with maximum 5.0 ohms resistance, install additional copper-clad ground rods as needed to achieve compliance, and bond all metallic components with #4 AWG green insulated copper jumpers. All existing marina power pedestals (A-1 through A-66) require elevation to the new finished grade with extended conduits and replacement conductors pulled to their respective disconnect switches, with sufficient slack wire provided for future MEE (Marine Shore Power) pedestal replacements by others. The design notes emphasize that existing conduit routing and condition are unknown, with the city having no as-built documentation; therefore, the contractor bears responsibility for evaluating all existing components and replacing any deemed unfit for reuse or damaged during construction. Marina operations for four boat clubs must continue throughout construction with work restricted to 7 a.m.–9 p.m. on weekdays and 9 a.m.–9 p.m. on weekends and holidays.
View the file
Other files for this state and local contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL NOTES
GRAPHIC SCALE
EP-01
ELECTRICAL NOTES
GENERAL NOTES
1. ELECTRICAL INSTALLATIONS SHALL COMPLY WITH THE FLORIDA BUILDING CODE, 2023 EDITION, WHICH ADOPTS THE 2020 NATIONAL ELECTRICAL CODE (NFPA 70). WHERE PROJECT SCOPE REQUIRES, INSTALLATIONS SHALL ALSO COMPLY WITH THE LATEST REQUIREMENTS OF THE NATIONAL ELECTRICAL SAFETY CODE (ANSI C2) AND/OR THE FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT). ALL CODES AND STANDARDS SHALL BE AS ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ).
2. ASCERTAIN THAT ALL ELECTRICAL SYSTEM COMPONENTS FURNISHED BY CONTRACTOR ARE COMPATIBLE IN ALL RESPECTS WITH FDOT STANDARDS AND SPECIFICATION, AND MEET ALL FDOT
REQUIREMENTS.
3. WHERE THE CONTRACTOR SELECTS TO FURNISH AND INSTALL EQUIPMENT REQUIRING ADDITIONAL WIRING, TRANSFORMERS, ADAPTERS, MOUNTINGS, ETC. TO THOSE SHOWN ON THE DRAWINGS AND/OR LISTED IN THE SPECIFICATIONS, ANY COST FOR THESE ITEMS SHALL BE INCIDENTAL TO THE EQUIPMENT COST.
4. COLOR CODE ALL PHASE WIRING BY THE USE OF COLORED WIRE INSULATION AND/OR COLORED TAPE. WHERE TAPE IS USED, THE WIRE INSULATION SHALL BE BLACK. PHASE CONDUCTORS SHALL BE USED FOR SINGLE-PHASE, THREE WIRE SYSTEMS. NEUTRAL CONDUCTORS SHALL BE WHITE OR NEUTRAL GRAY.
5. ALL BRANCH CIRCUIT CONDUCTORS CONNECTED TO A PARTICULAR PHASE SHALL BE IDENTIFIED WITH THE SAME COLOR. THE COLOR CODING SHALL BE CONTINUOUS AND EXTENDED TO THE POINT OF UTILIZATION. EXCEPT WHEN COLORED TAPE IS USED. TAPE SHALL BE APPLIED AT ALL ACCESSIBLE POINTS OF THE CIRCUIT TO IDENTIFY THE CIRCUIT'S NAME, FUNCTION.
6. FOR CONTROL WIRING, THE SAME COLOR SHALL BE USED THROUGHOUT THE SYSTEM FOR THE SAME FUNCTION.
7. ALL POWER AND CONTROL CIRCUIT CONDUCTORS SHALL BE COPPER; ALUMINUM WILL NOT BE ACCEPTED. THIS INCLUDES WIRE, CABLE, BUSSES, TERMINALS, SWITCH/PANEL COMPONENTS, ETC.
8. CONTROL AND POWER CIRCUIT CONDUCTORS SHALL BE INSTALLED IN SEPARATE CONDUITS.
9. NEATLY LACE WIRING IN DISTRIBUTION PANELS, WIREWAYS, SWITCHES AND JUNCTION/PULL BOXES.
10. EQUIPMENT CABINETS SHALL NOT BE USED AS PULL/JUNCTION BOXES. ONLY WIRING TERMINATING AT THE EQUIPMENT SHALL BE BROUGHT INTO THESE ENCLOSURES.
11. SPLICES AND JUNCTION POINTS SHALL BE PERMITTED ONLY IN JUNCTION BOXES, EQUIPPED WITH REMOVABLE COVERS, AND AT EASILY ACCESSIBLE LOCATIONS.
12. PROVIDE A SCHEDULE FOR ALL MATERIALS AND INCIDENTALS SPECIFIED IN THE PLANS AND REQUIRED DURING THE COURSE OF CONSTRUCTION.
13. ALL EXPOSED CONDUITS SHALL BE GALVANIZED RIGID STEEL.
14. PROVIDE ALL ELECTRICAL MATERIALS, TOOLS, AND TRANSPORTATION, AND PERFORM ALL SERVICES AND LABOR REQUIRED TO INSTALL A COMPLETE AND OPERABLE ITEM OR SYSTEM AS
INDICATED.
15. PROVIDE ALL FITTINGS, SUPPORTS, TRIMS, RELATED COMPONENTS AND APPURTENANCES NECESSARY FOR COMPLETE, COMPLIANT, OPERATIONAL AND FULLY FUNCTIONAL ELECTRICAL
INSTALLATIONS.
16. COMPLY WITH THE GENERAL REQUIREMENTS OF THE CONTRACT GOVERNING SUBMITTALS. CLEARLY IDENTIFY ALL SUBMITTALS WITH PROJECT NAME AND LOCATION, PRODUCT
MANUFACTURER'S PRODUCT CATALOG NUMBER, COMPANY NAME (CONTRACTOR), PROJECT MANAGER (CONTRACTOR), AND DATE REVIEWED. REVIEW AND APPROVE ALL SUBMITTALS PRIOR TO SUBMITTING TO THE ENGINEER. SUBMITTALS NOT SO MARKED AND APPROVED WILL BE REJECTED AND RESUBMITTAL REQUIRED. SUBMIT PRODUCT DATE CONSISTING OF CATALOG CUT SHEETS, BROCHURES, CIRCULARS, SPECIFICATIONS, PERFORMANCE DATA, INSTALLATION INSTRUCTIONS, CONTROL AND WIRING DIAGRAMS, DRAWINGS AND PRINTED INFORMATION IN SUFFICIENT DETAIL TO VERIFY COMPLIANCE WITH THE REQUIREMENTS OF THE CONTRACT. CLEARLY MARK PRODUCT DATA TO IDENTIFY PERTINENT PRODUCTS, MODELS, PART NUMBERS, FEATURES, AND OPTIONS BEING PROPOSED. IDENTIFY PERFORMANCE CHARACTERISTICS, CAPACITIES, DIMENSIONS AND REQUIRED CLEARANCES.
17. ELECTRICAL MATERIALS SHALL BE NEW AND SHALL BE ETL OR UL (UNDERWRITER'S LABORATORY, INC.) LISTED AND LABELED. INSTALL ELECTRICAL MATERIALS IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
18. INVESTIGATE THE EXISTING UTILITIES IN THE PROJECT AREA BEFORE ANY EXCAVATION OR BORING AND BE RESPONSIBLE FOR RESEARCHING AND INVESTIGATING THE EXISTING UTILITIES IN THE WORK AREA. THE UTILITIES SHOWN IN THE PLANS ARE THE BEST INFORMATION AVAILABLE TO THE ENGINEER AND DRAWN FOR THE CONTRACTORS INFORMATION. FIELD VERIFY
THE UTILITIES BEFORE ANY DIGGING, EXCAVATION, OR BORINGS.
19. COORDINATE WITH SITE DRAWINGS, OTHER DISCIPLINES, AND EXISTING CONDITIONS TO AVOID INTERFERENCE AND CONDITIONS THAT WILL NOT ALLOW THE INSTALLATION OF MATERIALS, AS INDICATED.
20. PULL BOXES SHALL BE SIZED WITH AT LEAST 50% MORE CAPACITY ABOVE AND BEYOND THE MINIMUM REQUIRED BY THE NEC UON.
21. LUMP SUM COST FOR THE ELECTRICAL SCOPE SHALL INCLUDE ALL ELECTRIC UTILITY SERVICE CHARGES AND ALL MONTHLY ELECTRIC USAGE FEES DURING CONSTRUCTION AND THE
CONTRACT PERIOD. THE COST OF ANY WORK REQUIRED BY UTILITY FOR THE SERVICE POINT INSTALLATION SHALL BE INCLUDED IN THE LUMP SUM COST. THIS MAY INCLUDE BUT IS NOT LIMITED TO: TRANSFORMERS, CONNECTIONS, CONCRETE PADS AND RAILINGS, CONTRIBUTION IN AID OF CONSTRUCTION CAIC.
22. THE LOCATION OF POWER SERVICE(S) HAVE BEEN COORDINATED WITH THE UTILITY COMPANY TO MAKE SURE THEY STAY WITHIN THE GENERAL UTILITY EASEMENT. PROVIDE AND BE RESPONSIBLE FOR ANY NECESSARY COORDINATION REGARDING MAXIMIZING THE USAGE OF UTILITY EASEMENT.
23. MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS PRIOR TO SUBMITTING BIDS. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED.
24. ARRANGE FOR ALL NECESSARY PERMITS, LICENSES, UTILITY COORDINATION, AND INSPECTIONS AS REQUIRED BY THE CITY/COUNTY OR UTILITY COMPANY. CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT COSTS REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID.
25. ALL STEEL CONDUITS FITTINGS, NUTS, BOLTS, ETC. SHALL BE GALVANIZED.
26. BOTH ENDS OF ALL CONTROL CONDUCTORS SHALL BE IDENTIFIED AS TO THE CIRCUIT, TERMINAL BLOCK, AND TERMINAL NUMBER.
27. PLASTIC END CAPS SHALL BE INSTALLED ON ENDS OF ALL UNISTRUT.
28. UNDERGROUND CONDUIT SHALL BE PVC SCH. 40, UON. UNDERGROUND CONDUIT SHALL TRANSITION TO PVC-COATED RGS CONDUIT WITH PVC TO RGS CONDUIT FITTINGS. CONDUIT SHALL BE
PVC-COATED RGS ABOVE GRADE THROUGH AND INCLUDING THE FIRST 90 DEGREE FITTING UNDERGROUND UON.
29. UNDERGROUND CONDUITS SHALL BE INSTALLED A MINIMUM OF 36" BELOW FINISHED GRADE, UON.
30. ANY SUBSTANDARD ELECTRICAL EQUIPMENT UNCOVERED DURING DEMOLITION AND CONSTRUCTION SHALL BE REPAIRED OR REPLACED TO PROVIDE A SAFE, COMPLETE, AND COMPLIANT
INSTALLATION. REQUEST DIRECTION FROM THE EOR VIA RFI PRIOR TO ANY DEVIATIONS FROM THESE PLANS.
31. ALL LIQUID-TIGHT, FLEXIBLE CONDUIT SHALL BE METALLIC.
32. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH FPL TO RAISE THEIR TRANSFORMERS TO ABOVE THE ELECTRICAL DATUM PLANE. INCLUDE ASSOCIATED COSTS IN THE BID.
ALL ELECTRICAL CONNECTIONS SHALL BE ABOVE THE ELECTRICAL DATUM PLANE, IF AN EXISTING METER, DISCONNECT, OR PANELBOARD IS NOT ABOVE, RAISE THE EQUIPMENT TO BE
ABOVE THIS PLANE.
33. AS PART OF THE SEA WALL RAISE PROJECT, THE ORIGINAL DESIGN SCOPE INCLUDED RAISING THE EXISTING LIGHT POLES ADJACENT TO THE SEA WALL TO MATCH THE NEW FINISHED GRADE ELEVATION. THE EOR RECOMMENDS THIS COURSE OF ACTION. THIS WORK WAS ACCOMPANIED BY A PHOTOMETRIC ANALYSIS TO ENSURE POST-CONSTRUCTION LIGHTING LEVELS REMAINED ADEQUATE. EOR WAS GIVEN THE CITY'S DIRECTION TO REMOVE THE RAISING OF THE LIGHT POLES AND THE ASSOCIATED PHOTOMETRIC ANALYSIS FROM THE SCOPE OF WORK.
THE FINAL DESIGN DOCUMENTS REFLECT THIS DIRECTIVE, WITH THE EXISTING LIGHT POLES SHOWN TO REMAIN AT THEIR CURRENT ELEVATION.
34. DESIGN INFORMATION IS BASED ON THE LIMITED AVAILABLE INFORMATION AT THE TIME OF DESIGN, AND A LIMITED SPOT-CHECK OF FIELD CONDITIONS. ENGINEER HAS MADE SEVERAL ATTEMPTS TO REQUEST ANY AS-BUILT OR ELECTRICAL PLANS DOCUMENTATION RELATED TO THE PARKS ELECTRICAL FACILITIES, WITH THE CITY MENTIONING THAT NO SUCH DOCUMENTATION EXISTS. THE EXISTING CONDUIT SYSTEM ROUTING AND CONDITION IS UNKNOWN AND THE CITY WOULD LIKE TO MAKE BEST EFFORT TO REUSE IT. THE CONTRACTOR SHALL THOROUGHLY EVALUATE THE EXISTING CONDITION AND BE PREPARED TO REPLACE ANY EXISTING CONDUITS (AND ANY INTERNAL CABLING/WIRING/CONDUCTORS) THAT ARE FOUND TO BE UNFIT FOR REUSE AND/OR BECOME DAMAGED DURING CONSTRUCTION. REPLACEMENT CONDUCTORS SHALL, AT A MINIMUM, BE THE SAME SIZE AS NOTED IN THE PLANS, WITH INSULATION MATERIAL SUITABLE FOR OCEAN SIDE / MARINE APPLICATIONS (XLPE PTFE OR PFA) XHHN-2. CONTACT THE EOR VIA RFI SHOULD ANY DEVIATIONS, CONFLICTING, OR CONCERNING
CONDITIONS BE DISCOVERED.
35. CONTRACTOR SHALL THOROUGHLY EVALUATE ELECTRICAL SYSTEM COMPONENTS THAT ARE TO BE REUSED (INCLUDING BUT NOT LIMITED TO: CIRCUIT BREAKERS, FUSES, BOLTS, UNISTRUT, TERMINATIONS, SWITCHES, ENCLOSURES, FASTENERS, SEALS, POLES, ETC.) AND REPLACE WITH EQUIVALENT ANY EQUIPMENT THAT IS FOUND TO BE UNFIT FOR REUSE AND/OR NO LONGER
COMPLIANT WITH THE NATIONAL ELECTRIC CODE (NEC) AND STATE STANDARDS, CODE.
36. CONTRACTOR TO PROVIDE STRUCTURAL CALCULATIONS RELATED TO THE CCTV/WIRELESS MAST(S), AND ELECTRICAL RACK(S), AS REQUIRED.
37. THE INTENTION IS TO REUSE THE EXISTING ELECTRICAL AND COMMUNICATIONS INFRASTRUCTURE, SHOULD ANY DAMAGE OCCUR DURING CONSTRUCTION THAT RESULTS IN A LESS THAN
100% FULLY OPERATIONAL SYSTEM, IT SHALL BE REPLACED WITH EQUIVALENT OR BETTER AND MEET CURRENT NATIONAL ELECTRIC CODE, CITED IN THE FLORIDA BUILDING CODE, MARINE AND LOCAL CODES; AND THE RESULT SHALL BE A FULLY OPERATIONAL SYSTEM. ADDITIONALLY IF PARTS ARE DISCOVERED TO BE UNFIT FOR REUSE , IT SHALL BE REPLACED WITH EQUIVALENT OR BETTER AND MEET CURRENT NATIONAL ELECTRIC CODE, MARINE AND LOCAL CODES; AND THE RESULT SHALL BE A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALL MAKE A THOROUGH EVALUATION OF THE EXISTING CONDITIONS, WITH PARTICULAR ATTENTION PAID TO ITEMS THAT ARE UNFIT FOR REUSE AND UNKNOWN ITEMS TO INCLUDE THEM IN THE BID.
38. EXISTING CONDUIT AND CONDUCTOR PATHS ARE DRAWN TO THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL CONDUCT A THOROUGH, ON-SITE FIELD INVESTIGATION AND VERIFICATION OF ALL EXISTING ELECTRICAL COMPONENTS. THIS CRITICAL INVESTIGATION MUST INCLUDE, BUT IS NOT LIMITED TO, CONDUIT ROUTES, CIRCUIT ROUTES, WIRING, SYSTEM CAPACITIES, PROTECTIVE DEVICE SPECIFICATIONS, CONDUCTOR SIZING, AND THE CURRENT STATE AND SPECIFICATIONS OF ALL INSTALLED LOAD CENTERS. THIS COMPREHENSIVE VERIFICATION IS PARAMOUNT TO ENSURING: AN ACCURATE BID, AND THAT THE FINAL CONSTRUCTION RESULTS IN A SAFE & FULLY NEC AND LOCAL CODE COMPLIANT ELECTRICAL SYSTEM.
NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR COSTS OR DELAYS ARISING FROM CONDITIONS THAT SUCH A THOROUGH FIELD INVESTIGATION WOULD HAVE REVEALED.
39. SEVERAL MARINA POWER PEDESTALS HAVE BEEN CAPPED OFF WITH ENCLOSURES. IN THE ABSENCE OF A MARINA PEDESTAL, RAISE THE ENCLOSURE; AND EXTEND ANY CONDUITS AND PULL NEW EQUIVALENT SIZE AND TYPE WIRING, PROVIDE SUFFICIENT SLACK WIRING AT EACH PEDESTAL TO ALLOW FOR FINAL CONNECTION OF THE REPLACEMENT PEDESTALS (BY OTHERS).
40. THE EXISTING POWER PEDESTALS SERVED BY THESE CIRCUITS ARE OUTSIDE THE SCOPE OF THIS PROJECT AND ARE NOT BEING MODIFIED OR REPLACED AT THIS TIME. IT IS THE EOR'S UNDERSTANDING THAT THE MEE (MARINE SHORE POWER) POWER PEDESTALS SHALL BE REPLACED WITH NEC COMPLIANT (GROUND FAULT PROTECTED PEDESTAL RECEPTACLES) SHORTLY AFTER THIS PROJECT COMPLETES (BY OTHERS). UPON REVIEW, IT HAS BEEN DETERMINED THAT THE EXISTING POWER PEDESTALS DO NOT COMPLY WITH THE SAFETY REQUIREMENTS OF THE 2020 NATIONAL ELECTRICAL CODE (NEC), AS ADOPTED BY THE 2023 FLORIDA BUILDING CODE. SPECIFICALLY, THE PEDESTALS LACK THE INDIVIDUAL 30MA GROUND-FAULT CIRCUIT-INTERRUPTER (GFCI) PROTECTION REQUIRED FOR EACH SHORE POWER RECEPTACLE, AS MANDATED BY NEC ARTICLE 555.35(A)(3).
41. GROUND ELECTRODE SYSTEM: PERFORM A 3-POINT FALL-OF-POTENTIAL TEST ON THE GROUNDING ELECTRODE SYSTEM AT THE EQUIPMENT RACK. THE RESISTANCE TO GROUND SHALL BE 5.0 OHMS OR LESS. IF RESISTANCE EXCEEDS 5.0 OHMS, INSTALL ADDITIONAL 5/8" X 20' COPPER-CLAD GROUND RODS (SPACED A MINIMUM OF 40 FT APART) AND INTERCONNECT WITH AN EXOTHERMICALLY WELDED #2 AWG BARE COPPER CONDUCTOR UNTIL THE REQUIREMENT IS MET. SUBMIT TEST REPORT TO THE EOR. ALL RODS IN THE SYSTEM SHALL BE BONDED TOGETHER USING A MINIMUM #2 AWG BARE COPPER GROUNDING ELECTRODE CONDUCTOR WITH EXOTHERMIC WELDS OR IRREVERSIBLE COMPRESSION FITTINGS.
42. EQUIPMENT BONDING: VISUALLY AND ELECTRICALLY VERIFY ALL ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO: STAINLESS STEEL (SS) EQUIPMENT RACKS, PEDESTALS, ENCLOSURES, PANELBOARD FRONTS, AND METALLIC COMPONENTS ARE CONTINUOUSLY BONDED TO THE GROUNDING SYSTEM. REMEDIATE ANY DEFICIENCIES BY INSTALLING #4 AWG GREEN
INSULATED COPPER BONDING JUMPERS WITH LISTED LUGS.
43. THE CONTRACTOR SHALL COORDINATE WITH THE CITY AND MARINA OPERATOR TO FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY SIGNS THROUGHOUT ALL APPROACHES TO THE MARINA AND DOCKING FACILITY IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC) ARTICLE 555.10. THE SIGNAGE SHALL MEET THE FOLLOWING REQUIREMENTS:
MESSAGE: THE SIGNS SHALL STATE THE FOLLOWING TEXT: "WARNING — POTENTIAL SHOCK HAZARD — ELECTRICAL CURRENTS MAY BE PRESENT IN THE WATER.".
PLACEMENT: SIGNS SHALL BE POSITIONED SO THEY ARE CLEARLY VISIBLE FROM ALL APPROACHES TO THE MARINA AND DOCKING FACILITY. THE CONTRACTOR SHALL SUBMIT PROPOSED SIGN PANEL CUT SHEETS TO THE CITY, MARINA OPERATOR, AND ENGINEER OF RECORD (EOR) FOR APPROVAL PRIOR TO ORDERING AND INSTALLATION.
DURABILITY: THE SIGNAGE AND ITS INSTALLATION SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE MARINE ENVIRONMENT.
ABBREVIATIONS
AMPS
ABOVE FINISH GRADE
AMERICAN WIRE GRADE
BELOW FINISHED GRADE
CONDUIT
CIRCUIT BREAKER
COMMUNICATION
DOWN
DRAWING
ELECTRICAL
ELECTRICAL TESTING LABORATORIES
EXISTING
FIBER OPTIC
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
HORSEPOWER
KILOVOLT AMP
KILOWATT
LIGHTING
LIGHTNING PROTECTION
MINIMUM
MOUNTED
A
AFG
AWG
BFG
C
CB
COMM.
DN
DWG
ELECT.
ETL
EX.
F.O.
GFCI
GND
HP
KVA
KW
LTG
L.P.
MIN
MNT.
NATIONAL ELECTRICAL CODE
NOT TO SCALE
OVERHEAD
QUADRUPLEX
RECEPTACLE
RIGID GALVANIZED STEEL
SCHEDULE
SURGE PROTECTION DEVICE
TELEPHONE
TRIPLEX
TYPICAL
UNDERWRITER'S LABORATORY
UNLESS OTHERWISE NOTED
VOLT
WEATHERPROOF (NEMA 4X)
NEC
N.T.S.
OH
QPX
REC
RGS
SCH
SPD
TEL
TPX
TYP
UL
UON
V
WP
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
SYMBOL DESCRIPTION
LIGHT POLE WITH ACORN FIXTURE
EXISTING PULL BOX
EXISTING CONDUIT WITH
EXISTING FPL SERVICE POINT &
PROPOSED PULL BOX
PROPOSED PANELBOARD
PROPOSED CONDUIT
LIMITS OF CONSTRUCTION
ELECTRICAL LEGEND:
LIGHT POLE WITH GLOBE FIXTURE
ILLUMINATED POWER PEDESTAL
PROPOSED CONDUCTOR
MAIN DISCONNECTS
SYMBOL DESCRIPTION
ELECTRICAL WORK:
POWER PEDESTAL
EXTEND EXISTING CONDUITS TO NEW ELEVATION.
PULL NEW CONDUCTOR FROM SOURCE TO PEDESTAL.
WIRELESS COMMUNICATIONS/CCVT MAST
EXISTING BURIED ELECTRIC (QL-B)
EXISTING BURIED ELECTRIC (QL-D)
EXISTING LUMINAIRE
EXISTING JUNCTION BOX
BURIED TELEPHONE (QL-B)
BURIED WATER (QL-B)
BURIED CABLE TV
BURIED SANITARY
EXISTING UTILITIES LEGEND:
STORM DRAIN
SANITARY VALVE COVER
WATER VALVE COVER
WATER METER
RECLAIMED WATER VALVE COVER
SURVEY MONUMENT
TRANSFORMER
SYMBOL DESCRIPTION
PROVIDE SUFFICIENT SLACK TO RECONNECT REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-16/17 EXISTING PEDESTAL TO BE RAISED.
PULL NEW WIRE, PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-14/15 EXISTING PEDESTAL TO BE RAISED.
PULL NEW WIRE, PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-4/5 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-2/3 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-1 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE, PROVIDE
SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO DEMOLITION AND CONSTRUCTION.
PREVENT DAMAGE TO EXISTING CONDUIT SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE
CONTINUOUS RUN OF CONDUIT FROM SOURCE TO DESTINATION.
A-12/13 EXISTING PEDESTAL TO BE RAISED.
PULL NEW WIRE, PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-10/11 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-8/9 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-6/7 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
EXISTING ELECTRICAL A-DOCK DISCONNECT 'B' TO
BE REPLACED WITH NEW PROTECTIVE DEVICES. SEE
ELECTRICAL DETAILS FOR MORE INFORMATION.
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
30 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
30 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
THREE NEW 2-1/2" CONDUITS
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N
(1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N
(1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N
(1)#2G
40 LF
THREE NEW 2-1/2" CONDUITS
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
FOUR NEW 2-1/2" CONDUITS
FEEDER 1: SLIPS A-1 THRU A-13: (2)3/0 (1)#3/0N (1)#2G
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
EOI
SARASOTA BAY
MARINA JACK
SARASOTA BAY
SARASOTA BAY
GRAPHIC SCALE
1 INCH = FEET
GRAPHIC SCALE
10 20 40
SYMBOL DESCRIPTION
LIGHT POLE WITH ACORN FIXTURE
EXISTING PULL BOX
EXISTING CONDUIT WITH
EXISTING FPL SERVICE POINT &
PROPOSED PULL BOX
PROPOSED PANELBOARD
PROPOSED CONDUIT
LIMITS OF CONSTRUCTION
ELECTRICAL LEGEND:
LIGHT POLE WITH GLOBE FIXTURE
ILLUMINATED POWER PEDESTAL
PROPOSED CONDUCTOR
MAIN DISCONNECTS
KEY MAP
EP-02
ELECTRICAL SITE PLAN
SYMBOL DESCRIPTION
ELECTRICAL WORK:
POWER PEDESTAL
PULL NEW CONDUCTOR FROM SOURCE TO POLE.
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
EP-02
EP-03
EP-05
EP-04
WIRELESS COMMUNICATIONS/CCVT MAST
EXISTING BURIED ELECTRIC (QL-B)
EXISTING BURIED ELECTRIC (QL-D)
EXISTING LUMINAIRE
EXISTING JUNCTION BOX
PROPOSED CONDUITZONE: ELECTRICAL DISCONNECT 'B': PHASE 1
EOI
A-22/23 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-28/29 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-32/33 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-24/25 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-26/27 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-30/31 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION
OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-34/35 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-36/37 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE, PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS).
EXISTING INFORMATION FOR A-36/27 IS CONFLICTING. CONTRACTOR TO INVESTIGATE AND REPORT TO EOR VIA RFI IF ADVERSE CONDITIONS ARE PRESENT.
A-18/19 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-20/21 EXISTING PEDESTAL TO BE RAISED. PULL NEW WIRE,
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
EXISTING CCTV / WIRELESS ASSEMBLY TO REMAIN.
SOFT DIG TO VISUALLY LOCATE AND IDENTIFY EXISTING
COMMUNICATIONS & POWER CABLING AND CONDUIT SYSTEM FROM
SOURCE TO DESTINATION. IF ANY DAMAGE OCCURS, REPLACE
EXISTING CONDUIT & CABLING WITH NEW EQUIVALENT CABLING
FROM SOURCE TO DESTINATION.
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO
DEMOLITION AND CONSTRUCTION. PREVENT DAMAGE TO EXISTING CONDUIT
SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE CONTINUOUS
RUN OF CONDUIT AND WIRING FROM SOURCE TO DESTINATION.
THREE NEW 2-1/2" CONDUITS
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
30 LF
THREE NEW 2-1/2" CONDUITS
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
THREE NEW 2-1/2" CONDUITS
FEEDER 2: SLIPS A-14 THRU A-23: (2)3/0 (1)#3/0N (1)#2G
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
TWO NEW 2-1/2" CONDUITS
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
TWO NEW 2-1/2" CONDUITS
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
TWO NEW 2-1/2" CONDUITS
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
TWO NEW 2-1/2" CONDUITS
FEEDER 3: SLIPS A-24 THRU A-31: (2)3/0 (1)#3/0N (1)#2G
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
40 LF
ONE NEW 2-1/2" CONDUITS
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
45 LF
ONE NEW 2-1/2" CONDUITS
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
45 LF
ONE NEW 2-1/2" CONDUITS
FEEDER 4: SLIPS A-32 THRU A-37: (2)3/0 (1)#3/0N (1)#2G
45 LF
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
EOI
SARASOTA BAY
MARINA JACK
SARASOTA BAY
1 INCH = FEET
GRAPHIC SCALE
10 20 40
KEY MAPKEY MAP
EP-03
ELECTRICAL SITE PLAN
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
EP-02
EP-03
EP-05
EP-04
SYMBOL DESCRIPTION
LIGHT POLE WITH ACORN FIXTURE
EXISTING PULL BOX
EXISTING CONDUIT WITH
EXISTING FPL SERVICE POINT &
PROPOSED PULL BOX
PROPOSED PANELBOARD
PROPOSED CONDUIT
LIMITS OF CONSTRUCTION
ELECTRICAL LEGEND:
LIGHT POLE WITH GLOBE FIXTURE
ILLUMINATED POWER PEDESTAL
PROPOSED CONDUCTOR
MAIN DISCONNECTS
SYMBOL DESCRIPTION
ELECTRICAL WORK:
POWER PEDESTAL
PULL NEW CONDUCTOR FROM SOURCE TO POLE.
WIRELESS COMMUNICATIONS/CCVT MAST
EXISTING BURIED ELECTRIC (QL-B)
EXISTING BURIED ELECTRIC (QL-D)
EXISTING LUMINAIRE
PROPOSED CONDUITZONE: ELECTRICAL DISCONNECT 'B': PHASE 1
A-54/55 EXISTING PEDESTAL TO BE RAISED AND
CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO
THIS PEDESTAL.
NOTE: THE SOURCE FOR EXISTING CIRCUITS A-54
AND A-55 IS CONFLICTING IN AS-BUILT
DOCUMENTATION (SHOWN ORIGINATING FROM
BOTH PANEL 'C' AND RACK 'A'). THE CONTRACTOR
SHALL FIELD VERIFY THE ACTUAL POINT OF
CONNECTION FOR THESE CIRCUITS AND SUBMIT A
REQUEST FOR INFORMATION (RFI) TO THE
ENGINEER OF RECORD (EOR) FOR DIRECTION
PRIOR TO COMMENCING ANY AFFECTED WORK.
A-38/39 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-40/41 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-42/43 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL. PROVIDE SUFFICIENT SLACK WIRE
TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-44/45 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-46/47 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE
EXTENDED TO NEW GRADE. PULL REPLACEMENT WIRE FROM PANEL 'C' TO
THIS PEDESTAL. PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE
CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-48/49 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-50/51 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO
NEW GRADE. PULL REPLACEMENT WIRE FROM PANEL 'C' TO THIS PEDESTAL.
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF REPLACEMENT
MEE PEDESTALS (BY OTHERS)
A-52/53 EXISTING PEDESTAL TO BE RAISED AND
CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL REPLACEMENT WIRE FROM PANEL 'C' TO
THIS PEDESTAL. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY OTHERS)
EXISTING AND LOAD CENTER PANEL 'C' TO REMAIN.
TERMINATION POINT FOR REPLACEMENT WIRE PULLS
FROM PANELBOARD TO PEDESTAL(S). REPLACEMENT
WIRE SIZE SHALL BE EQUIVALENT TO EXISTING.
REPLACEMENT WIRES SHALL MAINTAIN EXISTING
CONDUCTOR/CONDUIT PATH.
EXISTING CCTV / WIRELESS ASSEMBLY TO REMAIN.
SOFT DIG TO VISUALLY LOCATE AND IDENTIFY EXISTING COMMUNICATIONS & POWER CABLING AND CONDUIT SYSTEM FROM SOURCE TO DESTINATION. IF ANY DAMAGE OCCURS, REPLACE EXISTING
CONDUIT & CABLING WITH NEW EQUIVALENT CABLING FROM SOURCE TO DESTINATION.
EXISTING COMMUNICATION POLE AND EQUIPMENT TO REMAIN.
SOFT DIG TO VISUALLY LOCATE AND IDENTIFY EXISTING COMMUNICATIONS & POWER CABLING
AND CONDUIT SYSTEM FROM SOURCE TO DESTINATION. IF ANY DAMAGE OCCURS, REPLACE
EXISTING CONDUIT & CABLING WITH NEW EQUIVALENT FROM SOURCE TO DESTINATION.
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO
DEMOLITION AND CONSTRUCTION. PREVENT DAMAGE TO EXISTING CONDUIT
SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE CONTINUOUS
RUN OF CONDUIT AND WIRING FROM SOURCE TO DESTINATION.
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO
DEMOLITION AND CONSTRUCTION. PREVENT DAMAGE TO EXISTING CONDUIT
SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE CONTINUOUS
RUN OF CONDUIT AND WIRING FROM SOURCE TO DESTINATION.
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
3" CONDUIT
(2)3/0 (1)3/0N (1)#3G
2" CONDUIT
(2)3/0 (1)3/0N (1)#3G
2" CONDUIT
(2)3/0 (1)3/0N (1)#3G
FURNISH AND INSTALL PERMANENT
ELECTRICAL SAFETY SIGNS ON
APPROACHES TO THE MARINA AND
DOCKING FACILITY. SEE GENERAL
NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
EOI
SARASOTA BAY
MARINA JACK
SARASOTA BAY
SARASOTA BAY
GRAPHIC SCALE
1 INCH = FEET
GRAPHIC SCALE
10 20 40
KEY MAPKEY MAP
EP-04
ELECTRICAL SITE PLAN
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
EP-02
EP-03
EP-05
EP-04
SYMBOL DESCRIPTION
LIGHT POLE WITH ACORN FIXTURE
EXISTING PULL BOX
EXISTING CONDUIT WITH
EXISTING FPL SERVICE POINT &
PROPOSED PULL BOX
PROPOSED PANELBOARD
PROPOSED CONDUIT
LIMITS OF CONSTRUCTION
ELECTRICAL LEGEND:
LIGHT POLE WITH GLOBE FIXTURE
ILLUMINATED POWER PEDESTAL
PROPOSED CONDUCTOR
MAIN DISCONNECTS
SYMBOL DESCRIPTION
ELECTRICAL WORK:
POWER PEDESTAL
EXTEND EXISTING CONDUITS TO NEW ELEVATION
PULL NEW CONDUCTOR FROM SOURCE TO POLE.
CONDUCTOR SIZE SHALL MATCH EXISTING.
WIRELESS COMMUNICATIONS/CCVT MAST
EXISTING BURIED ELECTRIC (QL-B)
EXISTING BURIED ELECTRIC (QL-D)
EXISTING LUMINAIRE
ZONE: ELECTRICAL PANEL 'C': PHASE 2
EXISTING ELECTRICAL RACK 'A'.
PHYSICALLY DISCONNECT POWER AND LOTO PRIOR TO
DEMOLITION AND CONSTRUCTION.
MARINA POWER PEDESTALS A-54 THROUGH A-66.
APPLY ARC FLASH HAZARD LABELS PER NFPA70E.
REPLACE DAMAGED PII CONCRETE POSTS WITH NEW.
PULL NEW WIRES OF EQUIVALENT SIZE FROM EACH RAISED
PEDESTAL, THROUGH THE EXISTING CONDUIT SYSTEM, TO
ITS RESPECTIVE DISCONNECT SWITCH.
REWORK PROTECTIVE DEVICES AND GROUNDING/BONDING
AS DETAILED IN THE ELECTRICAL DETAILS SHEET.
A-66 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL NEW CONDUCTORS THROUG EXISTING CONDUIT SYSTEM. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-64/65 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO
NEW GRADE. PULL NEW CONDUCTORS THROUG EXISTING CONDUIT SYSTEM.
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF REPLACEMENT
MEE PEDESTALS (BY OTHERS)
A62/63 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO NEW GRADE.
PULL NEW CONDUCTORS THROUG EXISTING CONDUIT SYSTEM. PROVIDE SUFFICIENT SLACK
WIRE TO FACILITATE CONNECTION OF REPLACEMENT MEE PEDESTALS (BY OTHERS)
A-60/61 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO BE EXTENDED TO
NEW GRADE. PULL NEW CONDUCTORS THROUG EXISTING CONDUIT SYSTEM.
PROVIDE SUFFICIENT SLACK WIRE TO FACILITATE CONNECTION OF REPLACEMENT
MEE PEDESTALS (BY OTHERS)
A-58/59 EXISTING PEDESTAL TO BE RAISED AND CONDUIT(S) TO
BE EXTENDED TO NEW GRADE. PULL NEW CONDUCTORS
THROUG EXISTING CONDUIT SYSTEM. PROVIDE SUFFICIENT
SLACK WIRE TO FACILITATE CONNECTION OF REPLACEMENT
MEE PEDESTALS (BY OTHERS)
A-56/57 EXISTING PEDESTAL TO BE
RAISED AND CONDUIT(S) TO BE
EXTENDED TO NEW GRADE. PULL
NEW CONDUCTORS THROUGH
EXISTING CONDUIT SYSTEM. PROVIDE
SUFFICIENT SLACK WIRE TO
FACILITATE CONNECTION OF
REPLACEMENT MEE PEDESTALS (BY
OTHERS)
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO
DEMOLITION AND CONSTRUCTION. PREVENT DAMAGE TO EXISTING CONDUIT
SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE CONTINUOUS
RUN OF CONDUIT AND WIRING FROM SOURCE TO DESTINATION.
EXISTING WIRELESS MAST ASSEMBLY TO REMAIN.
IDENTIFY COMMUNICATIONS AND POWER CONDUITS AND
CABLING. PREVENT DAMAGE TO EXISTING SYSTEM.
(TYP) SOFT DIG AND VISUALLY LOCATE ALL EXISTING CONDUITS PRIOR TO
DEMOLITION AND CONSTRUCTION. PREVENT DAMAGE TO EXISTING CONDUIT
SYSTEM. IF DAMAGE OCCURS, CONTRACTOR SHALL REPLACE CONTINUOUS
RUN OF CONDUIT AND WIRING FROM SOURCE TO DESTINATION.
2-1/2" CONDUIT
FEEDER 2: SLIPS A56-A59: (2)3/0 (1)3/0N (1)#3G
2-1/2" CONDUIT
FEEDER 2: SLIPS A56-A59: (2)3/0 (1)3/0N (1)#3G
2-1/2" CONDUITS
FEEDER 3: SLIPS A60-A61: (3)#2 (1)#6G
FEEDER 2: SLIPS A56-A59: (2)3/0 (1)3/0N (1)#3G
2" CONDUITS
FEEDER 4: SLIPS A62-A65: (2)3/0 (1)3/0N (1)#3G
FEEDER 5: SLIP A66: (3)#3 (1)#6G
2" CONDUITS
FEEDER 4: SLIPS A62-A65: (2)3/0 (1)3/0N (1)#3G
FEEDER 5: SLIP A66: (3)#3 (1)#6G
2" CONDUIT
FEEDER 5: SLIP A66: (3)#3 (1)#6G
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
FURNISH AND INSTALL PERMANENT ELECTRICAL SAFETY
SIGNS ON APPROACHES TO THE MARINA AND DOCKING
FACILITY. SEE GENERAL NOTE #43 FOR MORE INFORMATION.
EOI
SARASOTA BAY
MARINA JACK
SARASOTA BAY
SARASOTA BAY
GRAPHIC SCALE
1 INCH = FEET
GRAPHIC SCALE
10 20 40
KEY MAPKEY MAP
EP-05
ELECTRICAL SITE PLAN
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
EP-02
EP-03
EP-05
EP-04
SYMBOL DESCRIPTION
LIGHT POLE WITH ACORN FIXTURE
EXISTING PULL BOX
EXISTING CONDUIT WITH
EXISTING FPL SERVICE POINT &
PROPOSED PULL BOX
PROPOSED PANELBOARD
PROPOSED CONDUIT
LIMITS OF CONSTRUCTION
ELECTRICAL LEGEND:
LIGHT POLE WITH GLOBE FIXTURE
ILLUMINATED POWER PEDESTAL
PROPOSED CONDUCTOR
MAIN DISCONNECTS
SYMBOL DESCRIPTION
ELECTRICAL WORK:
POWER PEDESTAL
EXTEND EXISTING CONDUITS TO NEW ELEVATION
PULL NEW CONDUCTOR FROM SOURCE TO PEDESTAL.
CONDUCTOR SIZE SHALL MATCH EXISTING.
WIRELESS COMMUNICATIONS/CCVT MAST
EXISTING BURIED ELECTRIC (QL-B)
EXISTING BURIED ELECTRIC (QL-D)
EXISTING LUMINAIRE
ZONE: ELECTRICAL RACK 'A': PHASE 2
EP-06
ELECTRICAL DETAILS
ELECTRICAL DETAILS
EXISTING MARINA POWER PEDESTALS
RAISE TO NEW ELEVATION, SEE CIVIL PLANS. AT A MINIMUM PEDESTALS
ENERGIZED PARTS SHALL BE ABOVE THE ELECTRICAL DATUM PLANE.
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
ELECTRICAL RACK 'A'
A-62 THRU 65 A-54 THRU 57
A-58 & 59 A-66 A-60 & 61
RACK 'A' IS THE TERMINATION POINT FOR REPLACEMENT WIRE PULL FOR SLIPS 54-66.
200A
SQUARE D
KAL26200
100A
SQUARE D
FAL24100
50A
SQUARE D
FAL24050
100A
SQUARE D
FAL24100
200A
MB
A-DOCK MAIN DISCONNECT 'B' EXISTING VIEW - FACING WEST - SLIPS A1 THRU A38
EXISTING ELECTRICAL PANEL 'C' ELEVATION VIEW
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
200A
SQUARE D
KAL26200
NOTES:
ELECTRICAL REQUIREMENTS: 2020 NEC, 2023 FBC
ALL ELECTRICAL CONNECTIONS AND EQUIPMENT SHALL BE ABOVE THE ELECTRICAL
DATUM PLANE. THE ELECTRICAL DATUM PLANE IS A HORIZONTAL PLANE THAT IS 2
FEET VERTICALLY ABOVE THE HIGHEST TIDE LEVEL FOR THE AREA.
ALL MARINA POWER PEDESTAL FEEDERS SHALL BE PROTECTED BY 100MA MAX GROUND
FAULT PROTECTION.
ALL CONDUCTORS SHALL BE OF TYPE XHHW-2. PROVIDE AN EQUIPMENT GROUNDING
CONDUCTOR (EGC) WITH EACH FEEDER CIRCUIT RUNNING TO THE POWER PEDESTALS.
THE EGC SHALL BE AN INSULATED COPPER CONDUCTOR WITH A CONTINUOUS GREEN
JACKET PER NEC 555.15.
INSTALL THE GFPE AND PROTECTION SYSTEM IN ACCORDANCE WITH ALL
MANUFACTURER'S PUBLISHED DOCUMENTATION AND WIRING DIAGRAMS.
EXISTING MEE (MARINA SHORE POWER) PEDESTALS OUTSIDE THE SCOPE OF THIS
PROJECT SHALL BE REPLACED (BY OTHERS) WITH MEE (MARINA SHORE POWER)
PEDESTALS THAT PROVIDE SHORE POWER RECEPTACLE GROUND FAULT PROTECTION
IMMEDIATELY FOLLOWING THIS PROJECT.
GROUND FAULT RELAY(S) CONTROL WIRING SHALL HAVE AN INLINE FUSE INSTALLED.
FUSE AMPACITY DICTATED BY THE CONTROL RELAY'S SPECIFICATIONS.
PROVIDE CONTINUOUS GROUND BONDING OF ALL METAL COMPONENTS THROUGH TO THE POINT OF SYSTEM GROUNDING.
PROVIDE GROUND TESTING, AND SUPPLEMENT WITH ADDITIONAL GROUND RODS UNTIL INSTALLATION MEETS NEC REQUIREMENTS.
LGL26400
A-DOCK MAIN DISCONNECT 'B' PROPOSED VIEW - FACING NORTH - SLIPS A1 THRU A38
HGA26150
RH99M
HGA26150
RH99M
JGA26175
RH99M
VERIFY/PROVIDE EGC AS REQUIRED FROM EACH DISCONNECT TO THE GROUND ROD(S) AT THE RACK.
EGC SHALL BE INSULATED WITH A CONTINUOUS GREEN OR GREEN WITH YELLOW STRIPE.
NOT TO SCALE
FEEDER 5
FEEDER 4
FEEDER 3FEEDER 2
FEEDER 1
HGA26150
RH99M
MAIN DISCONNECT 'B' - LOADING AND FEEDER CALCULATIONS
NOT TO SCALE
CONTRACTOR TO VERIFY ELECTRICAL EQUIPMENT MEET'S MINIMUM HEIGHT OF ELECTRICAL DATUM LINE. IF IT DOES NOT, COORDINATE WITH FPL AND RAISE EQUIPMENT TO THE REQUIRED ELEVATION.
DANIEL DIEZ
No. 92828
L I C E NS E
F L O R I DA
P R O F E S S I O N A L E N G I N E E
R
STATE OF
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL
BE RESPONSIBLE FOR THIS SHEET IN ACCORDANCE
WITH RULE 61G15-23.004, F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
GRAPHIC SCALE
EP-07
ELECTRICAL DETAILS
EXISTING ELECTRICAL PANEL 'A' HAZARD WARNING LABELS
INCIDENT ENERGY AT METER
EXISTING ELECTRICAL PANEL 'B' HAZARD WARNING LABELS
NOT TO SCALE
EXISTING ELECTRICAL PANEL 'C' HAZARD WARNING LABELS
NOT TO SCALE
INCIDENT ENERGY AT METER INCIDENT ENERGY AT METER
INCIDENT ENERGY AT MAIN DISCONNECT ENCLOSURE INCIDENT ENERGY AT MAIN DISCONNECT ENCLOSURE INCIDENT ENERGY AT MAIN DISCONNECT ENCLOSURE
INCIDENT ENERGY AT 'GROUP A' - EXISTING MARINA POWER PEDESTALS INCIDENT ENERGY AT 'GROUP B' - EXISTING MARINA POWER PEDESTALS INCIDENT ENERGY AT 'GROUP C' - EXISTING MARINA POWER PEDESTALS
1 INCH = FEET
GRAPHIC SCALE
25 50 100
PHASING NOTES AND QUANTITIES:
PHASE 1 QUANTITY NOTES:
SLIPS A1 THRU A37
SERVICE POINT / LOAD CENTER 'B'
GRAPHIC SCALE
EP-08
PHASING NOTES
PHASE 2 QUANTITY NOTES:
SLIPS A38 THRU A66
SERVICE POINT(S) / LOAD CENTER(S) 'A' AND 'C'
ddiez Snapshot
| 2025-10-28T10:57:22-0400 | |
| Daniel Diez |
| 2025-10-28T10:58:01-0400 | |
| Daniel Diez |
| 2025-10-28T10:58:23-0400 | |
| Daniel Diez |
| 2025-10-28T10:58:58-0400 | |
| Daniel Diez |
| 2025-10-28T10:59:41-0400 | |
| Daniel Diez |
| 2025-10-28T11:03:02-0400 | |
| Daniel Diez |
| 2025-10-28T11:01:17-0400 | |
| Daniel Diez |
| 2025-10-28T11:02:45-0400 | |
| Daniel Diez |
File details come from the government source that posted it. Updated .