About this file

This is a product specification document for the BraunAbility Vista Series wheelchair lift system, a fully automatic NHTSA-compliant commercial vehicle lift designed for accessible transportation. The Vista Series is available in two primary models—NVL917IB-2/NVL917FIB-2 and NVL919IB-2/NVL919FIB-2—with usable platform dimensions of 33" x 51" and 34" x 51" respectively. Both models feature an 800-pound lifting capacity, electrohydraulic power operation with 12VDC power supply, and are compliant with Federal Motor Vehicle Safety Standard 403 and the Americans with Disabilities Act of 1990 regulations under 49 CFR Part 38. The lift systems are designed for side or rear door applications and include dual handrails, integrated platform lighting, an adjustable anti-rattle feature, and a mechanically operated automatic roll stop. Installation kits are provided for multiple vehicle platforms including Dodge Ram Promaster, Ford E-Series and Transit, GM vehicles, and Mercedes-Sprinter vans, with additional accessories available such as retractable handrail restraints, control boxes, and padding kits.

The specification document establishes technical requirements for a lift system with a maximum hydraulic pressure of 2,495 psi, maximum current consumption of 70 amps at 12V, operating temperature range from 0°F to 140°F, and a durable high-gloss powder-coated finish meeting 1,000-hour salt spray corrosion resistance standards. The platform features a stowed height of 31 inches with a floor-to-ground travel distance of 48 inches and meets all NHTSA lighting and visibility requirements. The system includes a manual backup pump for operation during electrical failure, synchronized lifting cylinders for smooth jerk-free operation, and Teflon bushings at all pivot points for extended service life. This specification document serves as reference material for procurement professionals and specification writers developing bid documents or contract requirements for wheelchair lift installations in commercial transportation applications.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Vista Series™ Lift Guide 2-1-20

• Fully automatic NHTSA compliant lift, operated by an attendant

• Loading position - either direction

• Interfaces with OEM interlocks

• Lift mounted lights - platform illuminated as it deploys

• Unique stacking platform improves driver and passenger visibility through the window

• Low platform stowed height of 31” for easy viewing out of the window and access to the door lock normally blocked by the platform

• Hand control with illuminated functions

• Mechanically operated Automatic Roll Stop (ARS) that will transition to the fully up position as the platform leaves the ground

• Locking mechanical Inboard Barrier (IB), powder coated yellow for safety and high visibility, prevents movement if occupied

• Pump design prevents platform folding when occupied, quiet operation and low current draw

• Durable redesigned baseplate reduces lift weight and allows for quicker and easier service of hose/wiring

• Easily installed, step-by-step installation instructions, no peripheral hardware required

• Visual and audible warning provides notification of unsafe conditions

• Parallel arms lift with hydraulic cylinders

• Side or rear door application

• Dual handrails for security and convenience

• Bridging feature permits the wheelchair user to board the lift from sidewalks or inclines

• Floor to ground travel is 48”

• Lifting capacity is 800 lbs

• Integrated back-up pump

• Equipped with an adjustable anti-rattle feature to avoid unpleasant noise in the vehicle during transit

• Durable high-gloss powder coated finish

• Lift-Tite system stows the lift platform securely while the vehicle is in transit

• Pump module with removable cover offers easy access to all components

Vista Series™ Features

F = Front Pump IB = Inboard Barrier For a front-mounted pump assembly, add “F” to the model number when ordering (example: NVL917FIB-2).

General Function: Electrohydraulic, power up/gravity down operation

Operation: Hydraulic pump with two lifting cylinders

Control: hand-held control box

Hydraulic: Pressure Max. 2,495 psi, Fluid is Univis HVI 26, oil reservoir is .33 gal

Construction: Steel structure with powder coat finish

Operating Temperature: 0ºF to 140ºF

Power Supply: 12VDC

Current Consumption: Max. 70A (12V)

UP

DOWN32819

FOLD

UNFOLD

Hand-Held Pendant Control

Top Parallel Arms (2)

Adjustable Quiet-Ride Stow Blocks (2)

Main Cylinders (2)

Vertical Arm Covers (4)

Opposite Pump Side Vertical Arm

Handrails (2)

Outer Barrier

Saddle (2)

Outer Fold Arm (2)

Pump Side Vertical Arm

Bottom Parallel Arms (2)

Platform Lights Lift-Tite™

Latches (2) Unfold Assist Compression Springs (2)

Platform Side Plates (2)

Outer Barrier Latch (2)

Inboard PlatformInner Fold Arm (2)

Towers (2)

Threshold Warning

Plate

Audible Threshold Warning

Visual Threshold Warning

Inner Roll Stop

Pump Module (Rear)

Base Plate

Outboard Platform

NVL917IB-2 & NVL917FIB-2

NHTSA Compliant Usable Platform: 33” x 51”

NVL919IB-2 & NVL919FIB-2

NHTSA Compliant Usable Platform: 34” x 51”

Vista Series™ Models

Rear Pump IB lift model shown.

Clear Vertical Passageway is

1.375” Less Than

DoorOpening Height

Minimum Clear Door Opening Height

G

Clear Platform LengthB

Max.

Floor to GroundD

Overall Lift

Height

C

E Overall Lift Width

Clear Platform

WidthA

F Min. Clear Door Opening Width

H Threshold Area Depth

Lift Model Number

NVL917IB-2, NVL917FIB-2 384 800 33” 51” 56.25” 48” 47” 42” 57.375” 18”

NVL919IB-2, NVL919FIB-2 397 800 34” 51” 56.25” 48” 48” 43” 57.375” 18”

Clear Platform

Width

Clear Platform Length

Overall Lift

Height

Max.

Floor to Ground

Overall Lift

Width

Min. Clear Door

Opening Width

Min. Clear Door

Opening Height

Lift Weight lbs

Lifting Capacity lbs

A B C D E F GNVL2 Vista Series™

All dimensions are for reference only.

H Threshold

Area Depth

Vista Series™ Dimensions

Side Door withStd. LengthExt. Length
Side DoorSIde Curtain Air BagsRear DoorRear Door
Dodge Ram Promaster (2014 & up)38673KS38674KS
Ford E-Series30956K30957K30970K-42
Ford Transit (2015)400775KS400534KS400774KS400773KS
Ford Transit Template (2015)400779KS400801KS400778KS400778KS
GM30958K30959K30981K
Sprinter (2007 & up)34474KS34120KS401364KS
Sprinter (2014 & up)401174KS
Sprinter Template (2014 & up)401177KS

Van Mounting Kits contain floor reinforcements for 403/404 compliance.

33659KS

Replacement Hand-Held Control

35295K Upper Tower Support Kit

31579KS

Handrail Restraint Retractable -for 51” Platforms

35533KS

Handrail Restraint Retractable -for 54” Platforms

35331KS

Handrail Restraint Non-Retractable

Vista Series™ NHTSA Installation Kits

Vista Series™ Accessories

402606KS Padding Kit

COMMERCIAL WHEELCHAIR LIFT SPECIFICATIONS - IN COMPLIANCE WITH

United States Department of Transportation Rules and Regulations 49CFR, Part 38.

FROM THE AMERICANS WITH DISABILITIES ACT OF 1990 and NHTSA Rule 403 (2004) “Provided to make your spec writing easier.”

The wheelchair lift is compliant with Federal Motor Vehicle Safety Standard 403 for platform lift systems for motor vehicles. The lift shall have been tested to a minimum static load of 2400#. The lift shall have 800# rated lifting capacity. The base plate shall be a corrugated designed member to provide rigidity to minimize lift deflection when placed under load.

The power supply shall be a 12 volt electro-hydraulic system operating two single-acting cylinders.

The hydraulic power system shall allow for easy removal and field replacement. The operation of the unit shall provide a smooth, jerk-free ride in both up and down directions. The power operation of the hydraulic cylinders shall be of a pull-type design for smooth lifting operation and improved synchronous arm movement. The pivot pins in the trunnion (knuckle) of the pivot arms shall be of stationary design. The hydraulic system shall be regulated by two separate relief valves, one of which is designed to prevent accidental stowing when occupied.

The hand control for lift operation shall be of a one-hand operation design made of durable plastic.

The control box will provide user with illuminated functions. The control cable shall be coiled with quick-change connections for ease of maintenance or field change.

A manual back-up system shall be provided to ensure operation of the lift in case of electrical failure.

The backup system shall provide a reliable means of manually raising and lowering the lift while occupied. The back-up system shall fold and unfold the platform. The back-up pump shall be integrated with the hydraulic power pack system such that no hydraulic lines or fittings are required.

The platform shall be of steel construction, with two stackable sections for optimized view and minimized blind spots. The platform shall have a minimum usable wheelchair passageway width of 33 inches and a minimum usable length of 51 inches requiring a minimum 57 inch vertical clear door opening. All pivot areas shall be equipped with long life Teflon bushings. The sides of the platform shall be a minimum of 2.5 inches high.

The platform shall be automatically folded and unfolded and fully automatic in operation. The platform shall allow both inboard and outboard facing of wheelchair and mobility aid users. The platform entrance ramp shall be extruded aluminum for weight savings and have raised ribs for traction. The outer barrier must not raise if occupied with 25 lbs. The outer barrier shall be the sole outboard wheelchair retention device and shall be interlocked and comply with the FMVSS 403 requirements. Dual handrails shall be provided to add security and convenience. These handrails shall be 1.25 inch minimum diameter, minimum 30 inches in height, minimum of 8 inches in length, and withstand a 100# force in any direction (including vertical) without permanent deformation. The platform shall have “built in” lighting to meet 404 platform lighting requirements with no auxiliary lighting.

All lift components shall be finished with a baked-on powder coating, which will meet a salt spray test of 1000 hours, to provide corrosion resistance and a long service life. The BraunAbility Vista Series includes, but is not limited to the following model numbers:

• NVL917IB-2, NVL917FIB-2, NVL919IB-2, NVL919FIB-2

Vista Series™ Specifications

© 2020 BraunAbility. All rights reserved. All illustrations, descriptions and specifications in this brochure are based on the latest product information at the time of publication. BraunAbility reserves the right to make changes at any time without notice.

braunability.com 800.THE.LIFT ISO 9001:2015 631 West 11th Street, Winamac, IN 46996, USA